VISHWAS CONCRETE PRIVATE LIMITED
SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,
YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE
RMC UNIT - 1
SIEVE ANALYSIS OF COARSE AGGREGATE
SOURCE :HOSURE PLANT
DATE :
LOCATION :PLANT BIN
TYPE OF AGGREGATE 20.0mm
IS % Cum. % Cum. %
Weight retained, gms
Sieve, mm retained retained passing
40 0.0 0.00 0.00 100.00
25.00 0.0 0.00 0.00 100.00
20 145.0 2.90 2.90 97.10
12.5 3490.0 69.80 72.70 27.30
10 985.0 19.70 92.40 7.60
4.75 370.0 7.40 99.80 0.20
Pan 10.0 0.20 100.00 0.00
5000
LAB TECHNICAN QC-IN CHARGE
QC 5
GATE
9/8/2017
IS Limits as per IS
383-2016
100
100
85-100
-
0-20
0-5
VISHWAS CONCRETE PRIVATE LIMITED
SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,
QC 5
YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE
RMC UNIT - 1
SIEVE ANALYSIS OF COARSE AGGREGATE
SOURCE :HOSURE PLANT
DATE : 7/19/2017
LOCATION :PLANT BIN
TYPE OF AGGREGATE 20.0mm
IS % Cum. % Cum. % IS Limits as per IS
Weight retained, gms
383-2016
Sieve, mm retained retained passing
40 0.0 0.00 0.00 100.00 100
25.00 0.0 0.00 0.00 100.00 100
20 230.0 4.60 4.60 95.40 85-100
12.5 2210.0 44.20 48.80 51.20 -
32.20 81.00 19.00 0-20
10 1610.0
4.75 870.0 17.40 98.40 1.60 0-5
Pan 80.0 1.60 100.00 0.00
5000
LAB TECHNICAN QC-IN CHARGE
QC 5
SIEVE ANALYSIS OF COARSE AGGREGATE
SOURCE :HOSURE PLANT
DATE : 11/8/2017
LOCATION :PLANT BIN
TYPE OF AGGREGATE 20.0mm
IS Weight retained, % Cum. % Cum. % IS Limits as per IS
gms 383-2016
Sieve, mm retained retained passing
40 0.0 0.00 0.00 100.00 100
25.00 0.0 0.00 0.00 100.00 100
20 657.0 13.14 13.14 86.86 85-100
12.5 2851.0 57.02 70.16 29.84 -
19.22 89.38 10.62 0-20
10 961.0
4.75 531.0 10.62 100.00 0.00 0-5
Pan 0.0 0.00 100.00 0.00
5000
LAB TECHNICAN QC-IN CHARGE
VISHWAS CONCRETE PRIVATE LIMITED
SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,
YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE
RMC UNIT - 1
SIEVE ANALYSIS OF COARSE AGGREGATE
SOURCE :HOSURE PLANT
DATE :
LOCATION :PLANT BIN
TYPE OF AGGREGATE 20.0mm
IS Weight retained, % Cum. % Cum. %
gms
Sieve, mm retained retained passing
40 0.0 0.00 0.00 100.00
25.00 0.0 0.00 0.00 100.00
20 235.0 4.70 4.70 95.30
12.5 2463.0 49.26 53.96 46.04
10 1500.0 30.00 83.96 16.04
4.75 787.0 15.74 99.70 0.30
Pan 15.0 0.30 100.00 0.00
5000
LAB TECHNICAN QC-IN CHARGE
QC 5
ATE
9/19/2017
IS Limits as per IS
383-2016
100
100
85-100
-
0-20
0-5
VISHWAS CONCRETE PRIVATE LIMITED
SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,
QC 5
YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE
RMC UNIT - 1
SIEVE ANALYSIS OF COARSE AGGREGATE
SOURCE :HOSURE PLANT
DATE : 9/13/2017
LOCATION :PLANT BIN
TYPE OF AGGREGATE 20.0mm
IS % Cum. % Cum. % IS Limits as per IS
Weight retained, gms
383-2016
Sieve, mm retained retained passing
40 0.0 0.00 0.00 100.00 100
25.00 0.0 0.00 0.00 100.00 100
20 531.0 10.62 10.62 89.38 85-100
12.5 2563.0 51.26 61.88 38.12 -
36.58 98.46 1.54 0-20
10 1829.0
4.75 68.0 1.36 99.82 0.18 0-5
Pan 9.0 0.18 100.00 0.00
5000
LAB TECHNICAN QC-IN CHARGE