AND ANY ALTERATION THEREOF OR UNAUTHORIZED USE OF THE DESIGNS, DETAILS, SPECIFICATIONS, CONCEPTS
OR IDEAS THEREIN WITHOUT THE EXPRESS WRITTEN CONSENT OF THAT FIRM IS PROHIBITED AND IS A VIOLATION
DEMOLITION NOTES GENERAL NOTES GENERAL NOTES
THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE AND THE PROPERTY OF THE ARCHITECT
1) REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES NECESSARY FOR THE COMPLETION OF THE WORK AS DEPICTED ON THE 1) CONTRACTOR SHALL INSURE ALL WORK IS IN CONFORMANCE WITH ALL APPLICABLE BUILDING CODES. WORK SHALL BE COMPLETED IN 17) PAINTING FOR GYPSUM BOARD AND WOOD CONSTRICTION - PROVIDE TWO (2) FINISH COATS OF PREMIUM GRADE PAINT OVER SINGLE
DRAWINGS. INCLUDING BUT NOT LIMITED TO, ITEMS SHOWN ON THE PLANS WITH DASHED LINES. NECESSARY DISCONNECTS AND STRICT ACCORDANCE WITH THE LATEST EDITIONS OF THE N.Y.S. UNIFORM FIRE PREVENTION AND BUILDING CODE, N.Y.S. ENERGY COAT OF COMPATIBLE PRIMER, PROMAR 200 SERIES BY SHERWIN WILLIAMS, CLEVELAND, OHIO OR APPROVED EQUAL. ALL PAINT BY
ALTERATIONS TO EXISTING MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INCLUDED. PATCH AS REQUIRED ALL CONSTRUCTIONS TO CONSERVATION CODE, N.Y.S. PLUMBING CODE, NATIONAL ELECTRIC CODE, AND ALL OTHER FEDERAL, STATE AND LOCAL AGENCY SINGLE MANUFACTURER.
REMAIN IN ACCORDANCE WITH THE CONTRACT DRAWINGS. WHERE CONTRACTOR IS DESIGNATED TO MAKE REMOVALS, DISPOSITION OF REGULATIONS HAVING JURISDICTION OVER THIS PROJECT. IN THE EVENT OF ANY DISCREPANCIES BETWEEN AGENCY REQUIREMENTS.
PERMIT DOCUMENTS
MATERIALS IS THE RESPONSIBILITY OF THE CONTRACTOR. VERIFY WITH OWNER, THE DISPOSITION AND REMOVAL OF ANY COMPONENTS THE CONTRACTOR SHALL OBSERVE THE MORE STRINGENT OF REQUIREMENTS. 18) PROVIDE SLEEVE THROUGH FOUNDATION FOR PENETRATIONS AS REQUIRED. COORDINATE W/ CIVIL ENGINEERING DOCUMENTS.
DESCRIPTION
OF SALVAGEABLE VALUE.
2) ALL WORK SHALL COMPLY WITH THE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS (NBFU), INDUSTRIAL RISK 19) CONTRACTOR & MEP CONTRACTOR SHALL VERIFY LOCATION OF ROOF MOUNTED EQUIPMENT.
2) ALL REMOVALS AND SALVAGE, UNLESS SPECIFICALLY NOTED OR REQUESTED BY THE OWNER SHALL BECOME THE PROPERTY OF THE INSURANCE UNDERWRITERS (IRI), FACTORY MUTUAL (FW), OR THE APPLICABLE RATING BUREAU. THE NATIONAL ELECTRIC CODE (NEC),
REVISIONS
THIS DOCUMENT SHALL NOT BE USED FOR ANY OTHER PROJECT.
CONTRACTOR. THE AMERICAN GAS ASSOCIATION (AGA), AND THE AMERICAN SOCIETY OF HEATING AND AIR CONDITIONING ENGINEERS (ASHAE),
OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW.
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), APPLICABLE STATE AND CITY BUILDING CODES AND THE
3) REMOVE ONLY NON-LOAD BEARING CONSTRICTION AND PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO REMOVAL, THAT NO REQUIREMENTS OF ALL PUBLIC UTILITY COMPANIES SERVING THE PROJECT SITE.
STRUCTURAL COMPONENTS, I.E. BEARING WALLS, BEAMS, HEADERS, ETC.. SUPPORTING FLOOR, ROOF OR CEILING JOISTS ARE
DESIGNATED FOR REMOVAL. CONTACT THE ARCHITECT PRIOR TO REMOVAL OF ANY CONSTRUCTION IN QUESTION OR DEVIATING FROM 3) CONTRACTOR (AND HIS SUBCONTRACTORS) SHALL BE LICENSED BY THE STATE IN WHICH THE PROJECT IS LOCATED AND APPROVED IN
THE DESIGN INTENT. CONTRACTOR'S NON-CONTACT OF ARCHITECT PRIOR TO REMOVAL OF ANY WORK INDICATES HIS COMPLETE ADVANCE BY THE OWNER.
UNDERSTANDING THAT NO LOAD BEARING OR STRUCTURAL WORK IS BEING ALTERED UNDER THIS CONTRACT.
4) CONTRACTOR SHALL FILE ALL APPLICATIONS, PAY FOR ALL NECESSARY PERMITS AND SECURE CERTIFICATES OF OCCUPANCY FOR THE
4) ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED AND SHALL BE OF SUFFICIENT STRENGTH TO SUPPORT THE DESIGN LOADS AND TO PROJECT.
RESIST THE DEFORMATION CAUSED BY SUCH LOADS TO WHICH THEY SOIL PRESSURE INCLUDING SURCHARGE, HYDROSTATIC HEAD AND
IMPACT LOADS AS APPLICABLE. MINIMUM DESIGN LOAD VALUES SHALL BE AS FOLLOWS: 5) ALL WORK IS TO BE COORDINATED WITH THE OWNER. THE CONTRACTOR IS TO MEET WITH THE OWNER PRIOR TO STARTING
CONSTRUCTION. THE CONTRACTOR WILL PRESENT THE BUILDING PERMIT AND INSURANCE CERTIFICATES TO THE OWNER PRIOR TO
100 P.S.F. LIVE LOAD (FIRST FLOOR) STARTING CONSTRUCTION.
8/03/10
DATE
35 P.S.F. LIVE LOAD (SNOW)
20 P.S.F. DEAD LOAD (FLOORS/ROOF) 6) CONTRACTOR SHALL PROVIDE ANY NECESSARY MEASURES TO PROTECT THE WORKERS AND OTHER PERSONS DURING
MAXIMUM ALLOWABLE DEFLECTION @ L/360 OF SPAN CONSTRUCTION.
NO.
5) PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT LIMITED TO, GYPSUM BOARD, PLASTER, ACOUSTIC SYSTEMS, WOOD TRIM, 7) CHECK WITH THE OWNER FOR COORDINATION OF THE WORK UNDER THIS CONTRACT WITH WORK OF OTHER TRADES. OWNER'S
*
COVERS, BASE, PANELS, RAILS AND WAINSCOT. VERIFY MATCH OF NEW FINISH MATERIALS TO EXISTING IN COLOR, TEXTURE, REGULATIONS GOVERN ALL ASPECTS OF OUTSIDE CONTRACTORS WORKING ON THE PROPERTY.
THICKNESS, CUT, ETC TO SATISFACTION OF OWNER PRIOR TO INSTALLATIONS. PROVIDE OTHER MATERIALS TO MATCH EXISTING WHEN
REQUIRED. TO BE APPROVED BY OWNER. 8) CONTRACTOR SHALL KEEP THE JOB FREE OF DEBRIS AND MAKE FINAL CLEANUP TO THE SATISFACTION OF THE OWNER. CONTRACTOR
SHALL BE RESPONSIBLE FOR REMOVAL OF ALL CONSTRUCTION DEBRIS FROM PROJECT SITE AND SHALL PROVIDE DUMPSTERS ETC. AS
6) PATCH EXISTING WALLS GYPSUM DRYWALL OR PLASTER TO MATCH EXISTING OF SUFFICIENT THICKNESS TO MAINTAIN UNIFORM WALL REQUIRED. REMOVE ALL DEBRIS ON A DAILY BASIS. James A Rumsey
THICKNESS. ALL EXPOSED PORTIONS OF WALL SHALL BE FINISHED WITH THREE (3) COATES OF SPECKLING, SANDED AND LEFT IN A 5729 East River Road
PAINT READY CONDITION. 9) CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING BUILDINGS AND OTHER INSTALLATIONS THAT ARE TO Grand Island, NY 14072
REMAIN INTACT WHILE PERFORMING THE SPECIFIED WORK. PROVIDE AND MAINTAIN FIRE EXTINGUISHERS ON PROJECT SITE DURING James Rumsey
716.4447.9698
7) WHERE APPLICABLE LEVEL ALL EXISTING FLOORS AS REQUIRED TO RECEIVE NEW FLOOR FINISHES. INSTALL REQUIRED TRANSITION CONSTRUCTION.
PIECES BETWEEN VARIOUS FLOOR FINISHES SUITABLE FOR CONDITIONS AND ACCEPTABLE TO THE OWNER. MATCH EXISTING WHEREVER
POSSIBLE. 10) UNLESS INDICATED OTHERWISE, ALL MATERIAL FURNISHED AND INCORPORATED INTO THE WORK SHALL BE NEW, UNUSED AND OF
QUALITY STANDARD TO THE INDUSTRY FOR FIRST CLASS WORK OF SIMILAR NATURE AND CHARACTER. INSTALL ALL MATERIALS TO THE
MANUFACTURER'S RECOMMENDATIONS AND BEST STANDARD OF THE TRADES INVOLVED.
11) CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS IN FIELD PRIOR CONSTRUCTION. NOTIFY ARCHITECT OF ANY DISCREPANCIES ON
DRAWINGS.
12) VISIT THE SITE TO VERIFY EXISTING CONDITIONS. EXISTING CONCEALED CONDITIONS AND CONNECTIONS ARE BASED UPON
INFORMATION TAKEN FROM LIMITED FIELD INVESTIGATIONS. CONTRACTOR SHALL MAKE REQUIRED ADJUSTMENTS TO SYSTEM
COMPONENTS AS NECESSITATED BY ACTUAL FIELD CONDITIONS AT NO ADDITIONAL COST TO OWNER OR ARCHITECT. REPORT ANY
DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT BEFORE CONSTRUCTION BEGINS.
13) UNLESS OTHERWISE INDICATED ALL INTERIOR FINISHES SHALL BE AS DIRECTED BY THE OWNER.
14) CONTRACTOR TO OBTAIN AND PROVIDE OWNER WITH COLOR SAMPLES FOR PROPER COLOR SELECTION AND FINAL APPROVAL OF ALL
FINISHES PRIOR TO INSTALLATION.
15) INTERIOR FINISHES SHALL BE CLASS C (SURFACE FLAME SPREAD RATING OF 76-200) MINIMUM IN CONFORMITY WITH GENERALLY
ACCEPTED STANDARDS. CARPETING SHALL BE CLASS 2 WITH A MINIMUM CRITICAL RADIANT FLUX OF .22-WATTS PER SQUARE
CENTIMETER.
16) ALL GYPSUM BOARD WORK SHALL BE DONE IN ACCORDANCE WITH THE DRYWALL CONSTRICTION HANDBOOK, LATEST EDITION,
PREPARED BY UNITED STATES GYPSUM. ALL JOINTS AND SEAMS SHALL BE TAPED AND FINISHED IN ACCORDANCE WITH
PROJECT NO: pds3495
MANUFACTURER'S INSTALLATION RECOMMENDATIONS.
DATE: 06.22.10
DESIGNED BY: JAR
DRAWN BY: PDS
CHECKED BY: JAR
VERIFY ALL LINES, ANGLES AND DIMENSIONS BY
FIELD SURVEY AND MEASUREMENT.
Creative
Structures Services
210 Summer Street
Buffalo, New York 14222
TEL/FAX (716) 882-1226
PARKSIDE APARTMENTS
FILE LOCATION: 3596 00 A00 Cover.dwg
700 Parkside Avenue
GENERAL NOTES
Buffalo, New York
DATE PLOTTED: Tue, 03 Aug 2010 - 9:41am
DATE
6/22/10
DRAWING NO.
A0.1