Branch Reinforcement - ASME 31.1

The document summarizes the calculation of branch reinforcement for a pipe system. It provides details on the header pipe with a nominal pipe size of 300 NB, outside diameter of 323.8 mm, and schedule of 160. It also provides details on the branch pipe with a nominal pipe size of 25 NB, outside diameter of 33.4 mm, and schedule of 160. It then performs calculations to determine the required reinforcement area and any excess thickness based on the design pressure, temperature, material, and branch angle. The calculations show that no additional reinforcement is required.

Uploaded by

zakir84md3639
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
561 views8 pages

Branch Reinforcement - ASME 31.1

The document summarizes the calculation of branch reinforcement for a pipe system. It provides details on the header pipe with a nominal pipe size of 300 NB, outside diameter of 323.8 mm, and schedule of 160. It also provides details on the branch pipe with a nominal pipe size of 25 NB, outside diameter of 33.4 mm, and schedule of 160. It then performs calculations to determine the required reinforcement area and any excess thickness based on the design pressure, temperature, material, and branch angle. The calculations show that no additional reinforcement is required.

Uploaded by

zakir84md3639
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 8

Nominal Pipe Size (Header) 300 NB

Outside Diameter (Dh) 323.8 mm


Select Schdule

● Standard Extra Strong Double Extra Strong

5s 10s 20s 30s 40s 60s 80s


Th
100s 120s 140s ● 160s 33.32
Inside Diameter (Dhi)
257.16
Weight / M 238.69

NA - Not Availble

Nominal Pipe Size (Branch) 25 NB


Outside Diameter (Db) 33.4 mm
Select Schdule 160

Tb 6.35
Inside Diameter (Dbi) 20.70
Weight / M 4.24
mm
mm
Kg

mm
mm
Kg
Branch Re-inforcement Calculation ASME B31.1 104.3.1
TITLE
SUBJECT
Header: Branch:
Outside Diameter, Dh = 323.80 Outside Diameter, Db = 33.40
Provided Thickness, th = 33.32 Provided Thickness, tb = 6.35
Design Pressure, P (Kg/cm2) = 121.00 Design Pressure, P (Kg/cm2) = 121.00
Design Temperature, Th (oC) = 474.00 Design Temperature, Th (oC) = 474.00
Material of Construction SA 335 P22 Material of Construction SA 335 P22
Allowance, A = 1.00 Allowance, A = 1.00
Allowable stress, SE (Kg/cm2) = 972.7100176 Allowable stress, SE (Kg/cm2) = 972.7100176

Angle between axes of branch & run B, deg = 90

Required Reinforcement Area


A7= (tmh-A)*d1(2-SinB) tmh= P.Dh/(2.(SE+Py))+A tmb= P.Db/(2.(SE+Py))+A
= 20.185 mm = 2.983 mm
A7= 397.128 mm2
Hole dia., d1= [Db-2.(Tb-c)]/SinB
= 22.700 mm

Excess Thickness in Run Pipe Wall


A1= (2d2-d1)(th-tmh) d2= (tb-A)+(th-A)+d1/2 or d1
A1= 989.598 mm2 = 49.020 or 22.700 (which ever is greater)
= 49.020 mm

Excess Thickness in Branch Pipe Wall


A2= 2.L4.(Tb-tmb)/SinB L4= 2.5.(Th-A) or 2.5.(Tb-A)+tr
A2= 90.067 mm2 = 80.800 or 13.375 (which ever is less)
= 13.375 mm

A3 & A4 Area Provided by Welds and Attachments (Not Included).

AReq= Additional replacement area required = A7-A1-A2

AReq= -682.537 mm2

Using Pipe of min thickness 0.000 mm

A Pad of minimum width 0.00 mm is required.