P H OT O VO L T A IC S OF T W A R E
Software
We hope you will enjoy PVsyst !
Download General features New in PVsyst6 Final report Software development
General features
Grid-connected systems
For a given project (a defined site and meteo), you can construct several variations for your system (“calculation versions”).
• For the number of modules in a series: the upper diagram shows the I/V curve of the PV array, together with the MPPT range,
voltage, power, and current limits of the inverter.
• For the inverter sizing: the second graph displays the annual distribution of the array power, with the array and inverter nominal
power
• The optimal sizing of the inverter is based on the acceptable overload loss throughout the year. It usually leads to over-size the power
ratio (array nominal power by respect to the inverter nom. AC power), by a factor of 1.25.
After a good system sizing, you can define different losses like far and near shadings using a full 3D editor for the definition of the
environmental and near shading conditions.
Specialized tools are also provided for the evaluation of the wiring losses (and other losses like the module quality), the mismatch
between modules, soiling, thermal behavior according to the mechanical mounting, system unavailability, etc.
Main results:
1. The total energy production [MWh/y] is essential for the evaluation of the PV system's profitability.
2. The Performance Ratio (PR [%]) describes the quality of the system itself.
3. The specific energy [kWh/kWp] is an indicator of production based on the available irradiation (location and orientation).
• Shows the main energies and gains/losses involved in the simulation,
• Powerful tool for a quick analysis of the system's behavior, and potential improvements in the design.