0% found this document useful (0 votes)
343 views5 pages

Contactor A12-30-10 220-230v-50hz Bobina 230-240v-60hz

This document provides product information for an A12-30-10 220-230V 50Hz/230-240V 60Hz contactor. It includes technical specifications such as dimensions, electrical ratings, environmental withstand capabilities, certifications, and packaging details. The contactor is used to control 3-phase motors and power circuits up to 690V AC or 220V DC through its 3 main poles and 1 auxiliary contact.

Uploaded by

rpay_93
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
343 views5 pages

Contactor A12-30-10 220-230v-50hz Bobina 230-240v-60hz

This document provides product information for an A12-30-10 220-230V 50Hz/230-240V 60Hz contactor. It includes technical specifications such as dimensions, electrical ratings, environmental withstand capabilities, certifications, and packaging details. The contactor is used to control 3-phase motors and power circuits up to 690V AC or 220V DC through its 3 main poles and 1 auxiliary contact.

Uploaded by

rpay_93
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

A12-30-10 220-230V 50Hz / 230-

240V 60Hz
Products Low Voltage Products and Systems Control Products Contactors Block Contactors

General Information
Extended Product Type: A12-30-10 220-230V 50Hz / 230-240V 60Hz
Product ID: 1SBL161001R8010
EAN: 3471522042804
Catalog Description: A12-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
Long Description: A12 contactors are mainly used for controlling 3-phase motors and general
ly for controlling power circuits up to 690 V AC or 220 V DC. The contactor
s can also be used for many other applications such as isolation, capacitor
switching, lighting. The A... series 1-stack 3-pole contactors are of the bloc
k type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 bu
ilt-in auxiliary contact, front and side-mounted add-on auxiliary contact bloc
ks - Control circuit: AC operated with laminated magnet circuit - Accessorie
s: a wide range of accessories is available.

Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900

Popular Downloads
Data Sheet, Technical Information: 1SBC100122C0202_Ch02
Instructions and Manuals: FPTC407721P0001

Dimensions
Product Net Width: 44 mm
Product Net Depth: 74 mm
Product Net Height: 74 mm
Product Net Weight: 0.340 kg

Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 0
Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and Eur
opean standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (E
MC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 t
o IEC 947-4-1
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Supply Circuit 50 Hz
Supply Circuit 60 Hz
Conventional Free-air Thermal acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A
Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (690 V) 40 °C 27 A
(Ie): (690 V) 55 °C 25 A
(690 V) 70 °C 20 A
Rated Operational Current AC-3 (220 / 230 / 240 V) 55 °C 12 A
(Ie): (380 / 400 V) 55 °C 12 A
(415 V) 55 °C 12 A
(440 V) 55 °C 12 A
(500 V) 55 °C 12 A
(690 V) 55 °C 9 A
Rated Operational Power AC-3 (220 / 230 / 240 V) 3 kW
(Pe): (380 / 400 V) 5.5 kW
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
acc. to IEC 60947-4-1:

Rated Making Capacity AC-3 acc. 10 x Ie AC-3


to IEC 60947-4-1:

Rated Operational Current AC-15 (220 / 240 V) 4 A


(Ie): (24 / 127 V) 6 A
(380 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 32 A
Rated Short-time Withstand at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching AC-1 600 cycles per hour
Frequency: AC-2 / AC-4 300 cycles per hour
AC-3 1200 cycles per hour
Rated Operational Current DC-13 (125 V) 1.1 / 138 A
(Ie): (24 V) 6 / 144 A
(250 V) 0.55 / 138 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage 8 kV
(Uimp):

Mechanical Durability: 10 million


Maximum Mechanical Switching 3600 cycles per hour
Frequency:

Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
Rated Control Circuit Voltage (Uc): 50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil Consumption: Average Holding Value 50 / 60 Hz 8 V·A
Average Holding Value 50 / 60 Hz 2 W
Average Pull-in Value 50 Hz 74 V·A
Average Pull-in Value 60 Hz 70 V·A
Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Connecting Capacity Auxiliary Flexible with Cable End 0.75 ... 2.5 mm²
Circuit: Rigid Cable 1 ... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting terminals (delivered in M 3.5 (+,-) pozidriv 2 screws with cable clamp
open position) Main poles:

Terminal Type: Screw Terminals

Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude 3000 m
Permissible:

Resistance to Shock acc. to IEC Shock Direction: A 20 g


60068-2-27: Closed, Shock Direction: B1 10 g
Open, Shock Direction: B1 5 g
Shock Direction: B2 15 g
Shock Direction: C1 20 g
Shock Direction: C2 20 g
RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)


BV Certificate: BV_2634H07559D0
CB Certificate: CB_FR_602227A
CCC Certificate: CCC_2013010304615753
CCC_2004010309130463
CSA Certificate: CSA_1041746
Declaration of Conformity - CE: 1SBD250801U1000
DNV Certificate: DNV-GL_TAE00000TX
DNV GL Certificate: DNV-GL_TAE00000TX
EAC Certificate: EAC_RU C-FR ME77 B01010
Environmental Information: 1SBD250002E1004
GOST Certificate: GOST_POCCFRME77B07175
Instructions and Manuals: FPTC407721P0001
LOVAG Certificate: LOVAG_FR97038
LR Certificate: LRS_9830011E4
RINA Certificate: RINA_ELE128713XG001
RMRS Certificate: RMRS_0507015250
RoHS Information: 1SBD350050R1000
UL Certificate: UL_20160205-E312527-10-2
UL Listing Card: UL_E312527

Container Information
Package Level 1 Units: 1 piece
Package Level 1 Width: 78 mm
Package Level 1 Length: 76 mm
Package Level 1 Height: 47 mm
Package Level 1 Gross Weight: 0.34 kg
Package Level 1 EAN: 3471522042804
Package Level 2 Units: 63 piece
Package Level 3 Units: 1220 piece

Classifications
Object Classification Code: Q
E-nummer: 3227704
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
UNSPSC: 39121529

You might also like