BS-480 Chemistry Analyzer
BS-480 Chemistry Analyzer
Robust hardware
Enhanced Liquid System
Reagent and sample aspiration with extreme
accuracy and precision
Air bubble will be eliminated prior to washing
High pressure interior probe wash
Carry-over <0.05%
Economy Usage
Light-Spot Flatting Technology – an enhanced
optical system facilitates lower reaction volume
24 hours non-stop refrigeration at 2-10°C
Minimum sample volume: 1.5 μl
Reagent volume: 10 ~ 350 μl
Easy to perform maintenance
All containers & maintenance kits are located in
the front of the analyzer
Easily accessible for part replacement, routine
maintenance or troubleshooting
Step-by-step maintenance guide built in the
software design
Intelligent functions and smart
protection Tailor made
Support 4 reagents (R1, R2, R3 & R4)
Vertical and horizontal collision protection
Automatic System Recovery upon collision
Liquid level detection, clot detection
Advanced software
User-friendly Interface
Uniform platform of BS-2000 series, BS-800 series,
BS-480 and future instrument
Real-time status monitoring between analytical
unit and carousels
Bi-directional LIS interface transmission
Real-time QC Status Monitoring
Westgard Rules and Two-Control Evaluation
Levy-Jennings chart and Twin-Plot chart
Real-time alarm when QC result(s) is out of range
Auto QC setup capability
Traceable Test Results
Reagent, calibrator and control data can be
recalled from archive history
User-friendly, intuitive software design, easy
to recall from historical results
Reflex Function
Pre-defined reflexive assays will be performed
automatically when preset criteria is met
Each assay may involve multiple reflexive criteria
Each criteria may initiate up to a maximum of
20 relevant assays
Test Summary
e for your lab Test summary report calibration, QC, sample,
validation test and rerun tests can be generated
Facilitate computation of total test costs
Error Log Export function -facilitate error report
to engineers
Results Archive can be transferred to engineers
for evaluation
Accurate, Reliable Results
To ensure accuracy, reliability and correlation of diagnostic data, Mindray utilizes
the International Standard in result reporting. To assure ease of report retrieving,
Mindray establishes the Mindray Clinical Chemistry Measurement System for
result traceability.
Standard reference system
Adopt JCTLM reference system
IFCC primary method for enzyme, ID/MS method for substrate
NIST, IRMM reference materials
JCTLM, Joint Committee On Traceability In Laboratory Medicine
NIST, National Institute of Standards and Technology,USA
IRMM, Institute for Reference Materials and Measurements,EU
IFCC, International Federation of Clinical Chemistry and Laboratory Medicine
Complete traceability process Proficiency testing for reference measurement
Complete calibration hierarchy and traceability chain based on Participate RELA (External quality control for reference laboratory)
ISO standard (EN/ISO17511) from reference system to routine to verify the accuracy of the value assignment procedure.
measurement system
Traceability chain of Mindray measurement system (Glu)
Calibration /
Traceability Material Procedure Implentation Uncertainty
Value Assignment
Uc(y)
SI unit,mmol/L
Reference material Primary Reference
SRM 917C measurement procedure
Mindray Master CDC Hexokinase
Calibrator reference method
Mindray Product Mindray standard
Calibrator Measurement system
End user’ Routine Mindray
Routine Sample
Mindray
Result
International standardization certification
International Standardization certificates of Cholesterol and HbA1c from CRMLN and NGSP.
More information refers to website (http://www.cdc.gov).
CRMLN (Cholesterol Reference Method of Laboratory Network)
NGSP(National glycosylated hemoglobin standardization program)
Matched calibrators and controls
Dedicated calibrators with traceability and specific target value
Convenient design of multi items of calibrators and controls combined into one vial
Long shelf life of lyophilized powder
Dedicated, high-quality reagents
Diagnostic function test panels
Test panels such as : Hepatic panel, renal panel, pancreatic panel, lipid panel, cardiac
panel, diabetic panel, rheumatic factor panel
Reliable analysis performance
EP series standard (CLSI)-evaluate and optimize reagent system for reliable performance
in precision, linearity, stability, specificity and anti-interference capability
ISO standard manufacturing
Mindray follows straightly the ISO certified manufacturing process to ensure every lot of
reagent in production is of supreme quality
Reagent Menu
Enzymes Substrates
Alanine Aminotransferase (ALT) Total Cholesterol (TC)
Aspartate Aminotransferase (AST) Triglycerides (TG)
Alkaline Phosphatase (ALP) HDL-Cholesterol (HDL-C)
γ-Glutamyl Transferase (γ-GT) LDL-Cholesterol (LDL-C)
α-Amylase (α-AMY) Apolipoprotein A1 (ApoA1)
Lactate Dehydrogenase (LDH) Apolipoprotein B (ApoB)
Lipase (LIP) Direct Bilirubin (D-Bil) DSA
Cholinesterase (CHE) Direct Bilirubin (D-Bil) VOX
Adenosine deaminase (ADA) Total Bilirubin (T-Bil) DSA
α-L-fucosidase (AFU) Total Bilirubin (T-Bil) VOX
5'-nucleotidase (5'-NT) Total Protein (TP)
Creatine Kinase (CK) Albumin (ALB)
Creatine Kinase-MB (CK-MB) Total Bile Acids (TBA)
α-Hydroxybutyrate Dehydrogenase (α-HBDH) Glucose (Glu) GOD-POD
Glucose-6-phosphate dehydrogenase (G6PD) * Glucose (Glu) HK
Angiotensin converting enzyme (ACE) * Urea (UREA)
D3-hydroxybutyric acid (D3-HB) * Creatinine (CREA) Modified Jaffé
Creatinine (CREA) Enzymatic
Specific Proteins Uric Acid (UA)
Immunoglobulin A (IgA) Carbon dioxide (CO2)
Immunoglobulin G (IgG) Fructosamine (FUN)
Immunoglobulin M (IgM) Hemoglobin A1c (HbA1c)
Immunoglobulin E (IgE) * Cystatin C (CysC)
Complement C3 (C3) Microalbumin
Complement C4 (C4) β2-Microglobulin (β2-MG) *
C-Reactive Protein (CRP)
Lipoportein(a) [LP(a)] Inorganic ions
Prealbumin (PA) Calcium (Ca)
High sensitivity C-reactive protein (hs-CRP) Magnesium (Mg)
Rheumatoid Factor (RF) Phosphate Inorganic (P)
Antibodies Against Streptolysin O (ASO) Iron (Fe)
Homocysteine (HCY)
Ferritin (FER) Electrolytes/ISE
Transferrin (TRF) Chloride(Cl)
Total iron binding capacity / Potassium(K)
unsaturated iron Binding capacity (TIBC/UIBC) Sodium(Na)
Myoglobin*
D-dimer*
Retinol binding protein (RBP) *
* Coming soon
Mindray solution for clinical chemistry
Robust
hardware
Mindray
solution
for
clinical
chemistry
Advanced
software
Dedicated
reagent system
Mindray can now provide 60 parameters of dedicated reagents (more than 8 others are coming), covering
hepatic, renal, cardiac, lipids, diabetes, pancreatitis, inorganic ions and immunalassays, etc.,together with
original calibrators with metrological traceability as well as controls for BS-480 chemistry analyzer.
BS-480 Chemistry Analyzer
Technical Specifications
System function Reaction System
Fully automated, discrete, random access, Reaction rotor: Rotating tray, 90 cuvettes with automatic washing
STAT, urine and homogeneous immunoassays;STAT sample priority Cuvette: Optical length 5mm
Throughput: 400 photometric tests/hour, up to 240 tests/hour for ISE Reaction volume: 120~360µl
Measuring principles: Absorbance Photometry, Turbidimetry Operating temperature: 37°C
Methodology: End-point, Fixed-time, Kinetic, optional ISE Temperature fluctuation: ±0.1°C
Single/Dual/Triple/Quadruple reagent chemistries, Mixing system: 2 independent mixers
Monochromatic/Bichromatic
Programming: User defined profiles and calculation Optical System
Light Source: Halogen-tungsten lamp
Sample Handling Photometer: Reversed optics, grating photometry
Sample tray: 90 positions for primary or secondary tubes and sample cups Wavelength: 340nm, 380nm, 412nm, 450nm, 505nm, 546nm,
Sample volume: 1.5~45 µl, step by 0.1µl 570nm, 605nm, 660nm, 700nm, 740nm, 800nm
Sample probe: Liquid level detection, clot detection and collision protection Absorbance range: 0~3.3Abs (10mm conversion)
Probe cleaning: Interior and exterior automatic probe washing Resolution: 0.0001Abs
carry-over < 0.05%
Automatic sample dilution, Pre-dilution and post-dilution Control and Calibration
Dilution with ratio up to 1: 150 Calibration mode: Linear (one-point, two-point and multi-point),Logit
Dilution vessel: Cuvette -Log 4P, Logit-Log 5P, Spline, exponential, Polynomial,
Parabola
Internal bar code reader (optional) Control rules: Westgard multi-rule, Levy-Jennings, Cumulative sum
Sample/Reagent barcode reading – applicable to various bar code systems check, twin plot
including Codabar, ITF (Interleaved Two of Five), code128, code39,
UPC/EAN, Code93; Bi-directional LIS Interface transmission Operation Unit
Operation system: Window XP Professional or
ISE Module (optional) Windows 7 Professional (32bit)
Optional selection of K+, Na+, Cl- Interface: RS-232, Network Port, USB/ parallel port
Throughput: Up to 240 tests per hour
Working Conditions
Reagent Handling Power Supply: 200~240V, 50/60Hz, 1500VA
Reagent tray: 80 positions in refrigerated compartment (2~10°C) or 110~130V, 60Hz, 1500VA
Reagent volume: 10~350µl Temperature: 15~30°C
Reagent probe: Liquid level detection, collision protection and Humidity: 35~85%
inventory check Water consumption: ≤20L/hour, De-ionized water
Probe cleaning: Interior and exterior automatic probe washing Dimension: 1180mm x 710mm x 1150mm (W x D x H)
Weight: 300 Kg
P/N:ENG-BS-480-210285x8-20131010