See
discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/255171679
PAT (Process Analytical Technology) For “LIQUID PARENTERAL” Pharmaceuticals i.e. SVP & LVP Manufacturing Line ....
Article in Pharmaceutical Development and Technology · August 2013
CITATIONS READS
0 725
1 author:
Shivang Chaudhary
National Institute of Pharmaceutical Education and Research
59 PUBLICATIONS 74 CITATIONS
SEE PROFILE
Some of the authors of this publication are also working on these related projects:
Formulation R&D Engineer | Lean Quality by Design / Process Analytical Technology (F&D | Lean QbD / PAT) View project
All content following this page was uploaded by Shivang Chaudhary on 05 June 2014.
The user has requested enhancement of the downloaded file.
© Created & Copyrighted by Shivang Chaudhary
PROCESS ANALYTICAL TECHNOLOGY (PAT) FOR
LIQUID PARENTERAL PHARMACEUTICALS MANUFACTURING LINE
(
[email protected])
© Created & Copyrighted by Shivang Chaudhary
API / EXCIPIENT PURITY by STEAM FOR STERILIZATION WFI FOR CLEAN IN TEMPERATURE & RELATIVE
IN PLACE (SIP) PLACE (CIP) STEAM FOR STERILIZATION HUMIDITY by At Line
In line BRUKER FT-NIR WFI FOR CLEAN IN
STEAM FOR STERILIZATION WFI FOR CLEAN IN IN PLACE (SIP) Thermo-hygrometer
pH METER & PLACE (CIP)
IN PLACE (SIP) PLACE (CIP) DO METER NITROGEN
NITROGEN NITROGEN FLUSHING
API / EXCIPIENT PARTICLE FLUSHING FLUSHING DO METER
VACCUM & PRESSURE
SIZE DISTRIBUTION by DO METER PUM SYSTEM VACCUM & PRESSURE
In line Lasentec FBRM
COMPOUNDING PUM SYSTEM
VACCUM & PRESSURE VESSEL STORAGE
PUM SYSTEM VESSEL
STERILE
RATE OF STIRRING FOR COMPLETE
VACUUM WATER FOR INJECTION
WATER PHASE HOMOGENIZED STATE FOR SOLUTION
TRANSFER MANUFACTURING
HEATING & MIXING & by BRUKER FT-NIR
SYSTEM STORAGE
VESSEL VESSEL
WORKING
PLATFORM
RATE OF STERILIZATION by In RATE OF STERILIZATION by In
Line Chemical Indicator for Line Chemical Indicator for
Parametric Release Parametric Release
INTEGRATED FILTRATION FILTRATION
PYROGENS / ENDOTOXIN
CONTROL PANEL
RATE OF STERILIZATION by At ASSEMBLY & RATE OF CONTROLLED FLOCCULATION ASSEMBLY &
OR EFFECTIVE PRECIPITATION by In DETECTION by In Line
Line Bacteriological Indicator TRANSFER TRANSFER
Line Lasentec FBRM or PVM OR STERLIZATION PROCESS
for Parametric Release PUMPS PUMPS
At Line SVR/SHR Tests FOR PARAMETER S RECORDING
SUSPENSION OR EMULSIONS OR At Line LAL Test
LIQUID PARENTERAL (BFS) MANUFACTURING LINE WITH CONTROL STRATEGY &
PROCESS ANALYTICAL TECHNOLOGY
© Copyrighted by Shivang Chaudhary
View publication stats