1
ID- DEC. 2016
BRUSHBOND constructive solutions
Acrylic polymer modified cementitious
waterproofing coating for concrete and
masonry surfaces
simply by a stiff brush, roller or trowel to obtain the desired
Uses
texture.
Fosroc Brushbond is a cementitious waterproofing
Brushbond consist of specially selected cements, graded
system formulated to waterproof, fill and seals pores and
hard wearing aggregates and additives supplied in powder
voids of all masonry and concrete as follow:
form together with a liquid component of blended acrylic
Planter box copolymers.
Reservoirs and water tanks The acrylic polymer provides Brushbond with exceptional
adhesion, resiliency, flexibility, toughness, and durability.
Fountains
Toilets: bathrooms and kitchen
Application Instruction
Basement
Protection
Retaining wall and tunnel
Concrete gutter The waterproof coating should be protected from rain, dirt,
oil, grease or other loose material during its drying time.
Advantages
The main contractor should take precautions to protect the
Minimum surface preparation needed. waterproof coating from any mechanical damage the
Applied directly to the concrete and masonry. construction of nearby works.
Excellent adhesion bonds to porous and non-porous
surfaces.
Non-toxic. Ideal for portable water tanks.
Excellent adhesion to porous and non – porous
surfaces
Excellent for damp proofing basements below grade
Excellent for pointing leaking brick and masonry walls
Breathable – allows transmission of water vapour
from interior of building
High resistance to carbon dioxide, chloride and ion
diffusion
Self -curing, no fear of premature drying.
Description
Brushbond is a two component acrylic polymer modified
cementitious coating which is supplied in easy to use kits. Brushbond Waterproofing System to elevated RC
By varying the mix proportions, Brushbond can be applied Reservoir
Page 1
1
ID- DEC. 2016
BRUSHBOND constructive solutions
Water vapour
transmission, 7.7 mm ASTME - 96 +/- 11 perms
coating thickness
Spesification Clauses
Performance specification
All surface waterproofing (specify details and areas of
application) must be carried out using a pre packed two
component cement based products, which contains
polymer modifiers.
The storage handling and application of the product must
be in strict accordance with the manufacturer’s
instructions.
Application Insructions
Preparation
All the surface which are to receive Brushbond coating
must be free from oil, grease, wax, dirt or any other form
Properties of foreign matter which might affect adhesion. Spoiled and
Typical Properties deeply disintegrated concrete should be removed to
o
Pot Life at 35 C : +/- 60 minutes sound concrete and repaired with repair product like
Available Colour : Grey and White Fosroc RENDEROC series.
Mixing
Typical cured Properties Add the powder component gradually to the liquid
Properties Test Method Brushbond avoiding lump formation and mix for 3- 5 minutes till
Coating homogeny. Do not add with water because can reduce
the waterproofing effectiveness. Continue mixing during
Water Absorption,% ASTM C - 642 < 0.3 applications.
Adhesion to Concrete
Application
2
N/mm : >= 1
Damp the surface before coating with water.
Elongation, % : ASTM D638 <10% o
Application of Brushbond on hot substrates (i.e. 40 C
Permeability : DIN1048 <2%
Page 2
1
ID- DEC. 2016
BRUSHBOND constructive solutions
surface temperature) will need the prior application of Cleaning
a primer coat.. Mix Brushbond and water in slurry like Brushbond should be removed from tools and equipment
consistency and applied on substrate. Only applied in area immediately after use with clean water. Hardener material
where brushbond will be coated. Apply Brushbond over can be removed mechanically.
the primer whilst the primer still wet.
Use a short, stiff bristle brush preferably 120 to 200 mm in Packaging
width. Apply minimum two coats for best result. Spray or Brushbond is supplied in an industrial kit of 22.5 kg pack
trowel application can be undertaken as necessary using which consist of:
the correct mixing ratio to obtain satisfactory consistency. Powder : 17.5 kg
It is recommended that for general resurfacing each coat Liquid : 5.0 kg
should be 1mm thick. Areas subjected to light foot traffic
should receive at least 2mm thickness of Brushbond and Consumption
an additional 2mm should be applied if conditions are Depending on the usage of the surface to be coated, the
moderate to heavy pedestrian traffic. approximately consumption is as follow:
Limitation Usage Consumption Thickness
-Where subsequent coatings or paints are required, trials Protective coating : 1.5 kg/m2 0.9 mm
should be conducted to ensure compatibility. Waterproofing for
-Brushbond should not be applied if the air or substrate toilet or bathroom : 2 kg/m2 1.2 mm
temperature is greater than 45°C. This may result in Waterproofing for
different colour shades. swimming pool or
- Brushbond should not be applied if the temperature of reservoir : 3 kg/m2 1.8 mm
the substrate is below 5°C. Storage
- Brushbond should not be applied where there is a Brushbond has a shelf life of 12 months in unopened pack
likelihood of exposure to frost within 48 hours of the o
(T: 25- 35 C, RH < 55%), kept in a dry store. In high
application. temperature and humidity locations, the shelf life may be
- Brushbond should not be applied in windy conditions reduced to 6 – 8 months.
where early-age dust adhesion may occur, or where rain Precautions
is likely within 2 hours at 20°C or 20 hours at 5°C (up to Health and safety
80% RH). Brushbond shall not be applied during rain or when rain is
expected. Brushbond is non – toxic but it is alkaline in
nature. Gloves and googles should be worn. Any splashes
Page 3
1
ID- DEC. 2016
BRUSHBOND constructive solutions
to the skin or eyes should be washed off with clean water. Fire
In the event of prolonged irritation, seek medical advice. Brushbond components are non – flammable.
Powder products should be handled to minimise dust
formation, use a light mask if excessive dust in
unavoidable.
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the
PT.FOSROC Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any advice,
recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct or continuous control
Indonesia
over where or how its products are applied, accept any liability either directly or indirectly arising from the use of its products, whether or
not in accordance with any advice, specification, recommendation of information given by it.
Jl.Akasia II Blok A8 No.1
Delta Silicon Industrial Park telephone: fax: email:
Lippo Cikarang
+62 21 897 2104-06 +62 21 897 2107
[email protected]Bekasi 17550
Indonesia
www.fosroc.com
Page 4