DYWIDAG Prestressing Systems using Bars
Contents
ETA Approvals............................................................................................................ 4
System description..................................................................................................... 5
Prestressing Bars / Technical Data............................................................................. 6
System overview......................................................................................................... 7
Overview of anchorages............................................................................................. 8
Applications................................................................................................................ 9
Overview of bonded bar tendons.............................................................................. 10
Overview of unbonded and external bar tendons...................................................... 11
Geometrical characteristics of accessories.............................................................. 12
Installation................................................................................................................ 13
Stressing and grouting.............................................................................................. 14
Equipment for stressing and grouting....................................................................... 15
ETA Approvals
Construction products with an Euro-
pean Technical Approval (ETA) meet
all essential demands given in the
Construction Products Directive (CPD).
The ETA holder is authorized to apply the
CE-marking (ConformitÈ EuropÈenne)
on his product. The CE-marking certi-
fies the conformity with the technical
specification and is the basis for the
free movement of goods within the EU
member states. DSI is proud to have
European Technical Approvals for its
PT-systems with bars, bonded strands
and unbonded strands.
4
System Description
Typical Coupling, Uhlavu Bridge, Pilsen, Czech Republic
DYWIDAG Prestressing Systems are is achieved with optimized material se-
world renowned for reliability and lection andcautious detailing of all the
performance, most suitable for all components especially in their system
applications in post-tensioned and assembly.
prestressed constructions. They
embrace the whole spectrum from The bar systems for prestressed
bridge construction, buildings, to civil structure: bonded, unbonded
applications, above and underground. and external tendons resp. are
regulated in the European Technical
The first ever structure built with a pro- Approval ETA-05/0123. This ETA
totype DYWIDAG Post-Tensioning can be downloaded at
System using bars was the arch-bridge www.dywidag-systems.com.
Alsleben (Germany) in 1927. From that
time on DYWIDAG has continuously For geotechnical applications a ground
improved its systems to keep up with the anchor with 47 mm threadbar diame-
growing demand of modern construction ter will be provided, too. A x 47 mm
technology. In addition to the traditional threadbar prestressing tendon is in pre-
post-tensioning system using bars, that paration. Additionally DSI-USA provides
is mainly geared towards geotechnical DYWIDAG Prestressing Systems with
applications, building rehabilitation and threadbars 65 and 75 mm.
strengthening, DSI offers a complete
product line in strand prestressing (bon- The intended use for internal bar ten-
ded, unbonded and external) as well as dons is for concrete, composite and
stay-cables being able to fully serve the masonry structures. Internal unbonded
post-tensioning construction. DYWIDAG and external bar tendons will be used for
Prestressing Systems have always com- concrete, composite, steel, timber and
bined highest safety and reliability stan- masonry structures.
dards with most economical efficiency
in their research and development. De- Typical applications are transversal
pendable corrosion protection methods prestressing, strengthening of bridges,
of the DYWIDAG Prestressing Systems rehabilitations, connection elements
contribute to the longevity of modern for steel structures and machines and
construction. High fatigue resistance temporary applications. Uhlavu Bridge, Pilsen, Czech Republic
5
Prestressing bars and technical data
General
The prestressing bars are hot-rolled, tem- The bars are of prestressing steel The threadbars and plain bars are
pered from the rolling heat, stretched and Y 1050 H according to prEN 10138-4. available in mill length up 18 m and
annealed, with a circular cross section. may be cut to specified lengths before
shipment to the jobsite.
Threadbars
Threadbars are available in diameters
26.5, 32, 36, 40 and 47 mm.
The threadbars feature continuous
hot-rolled ribs providing a right-handed
thread along the entire length.
The threadbar can be cut anywhere and
is threadable without further preparation.
The threadbars are specified by
nominal diameter and WR, e.g. 26 WR
Plain bars
Plain bars are available in diameters
32 and 36 mm.
Both ends of a plain bar cut to the length
specified in the project are provided with
special cold-rolled threads.
The thread lengths are manufactured in
the shop according to the specifications
of the project.
The plain bars are specified by
nominal diameter and WS, e.g. 32 WS.
Technical data
ThreadbarÆ Plain bar
Designation – – 26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
Nominal diameter ds mm 26.5 32 36 40 47 32 36
Cross section area Sn mm² 552 804 1018 1257 1735 804 1018
Nominal mass per metre M kg/m 4.481) 6.531) 8.271) 10.211) 14.101) 6.31 7.99
Pitch c mm 13 16 18 20 21 3.0 3.0
Characteristic breaking load Fm kN 580 845 1070 1320 1820 845 1070
Max. initial stressing force
Pm0,max = Sn x 0.8 x fp,k kN 464 676 856 1056 1456 676 856
Max. overstressing force
P0,max = Sn x 0.95 x fp0,1k kN 499 722 912 1130 1567 722 912
1) The nominal mass per metre includes 3.5% not load bearing portion of ribs.
6
System overview
Available tendons 26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
QR-plate anchorage N N N N N
Bonded bar tendon
with additional reinforcement
QR-plate anchorage N N N N N
without additional reinforcement
Rectangular solid plate anchorage N N N N N N N
with additional reinforcement
Rectangular solid plate anchorage N N N N N
without additional reinforcement
Square solid plate anchorage N N N N N
without additional reinforcement
Unbonded and Rectangular solid plate anchorage N N N N N N N
external bar tendon with additional reinforcement
Square solid plate anchorage N N N N N
without additional reinforcement
7
Overview of anchorages
Stressing anchorage, bonded domed anchor nut
The bar is fixed with the domed prestressing bar WR/WS
anchor nut and the retaining nut to the
anchorage plate and this latter will be
fixed to the scaffolding. The retaining
nut provides the connection to the duct.
Grouting is performed through the grout
cap, the domed anchor nut with the three
grout slots and the retaining nut. hex nut
toroidal ring retaining nut
grout cap anchor plate
sealing ring
anchor plate
Fixed anchorage, bonded
domed anchor nut The fixed anchorage is mostly
completely embedded in the con-
crete. The domed anchor nut is tack
welded perpendicularly onto the anchor
plate. The duct sleeve B ends direct-
ly at the anchor plate the duct will be
injected respectively vented there. A
duct sleeve B
fixed anchorage can be designed as a
stressing anchorage; the required
prestressing bar WR/WS bar-over length for the stressing can be
dispensed.
anchor plate with connection tube
Stressing anchorage, unbonded domed anchor nut
tube
Against water intrusion in the
anchorage region a connection tube is
welded to the anchor plate for bridging of
a gap behind the anchor plate.
Different corrosion protection systems
are available.
prestressing bar WR/WS heatshrinking sleeve
prestressing bar WR/WS domed anchor nut
Fixed anchorage, unbonded
The fixed anchorage is mostly
completely embedded in the concrete.
The domed anchor nut is tack welded
perpendicularly onto the anchor plate.
The prestressing bar will be provided
with the respective corrosion protection.
tube
heatshrinking sleeve The fixed anchorage can be carried out
anchor plate as an unbonded stressing anchorage,
too.
8
Applications
Prestressing bar tendons can be used connections of precast concrete
at new structures and for strengthening elements, fixations of concrete to
of existing structures, as longitudinal concrete, new concrete to old concrete,
or transversal tendons, as shear steel to concrete, concrete to masonry
reinforcement, straight or curved, or any combination of members made of
as hangers at concrete or steel arch any structural material.
bridges, for temporary or permanent
Grand-MÈre Generating Station, Canada
Church of Our Lady, Germany
9
Overview bonded bar tendons
Bonded bar tendons are embedded in A bonded tendon is intended
concrete. The corrosion protection of the to be used for concrete, composite
prestressing steel and the bond with the and masonry structures.
structural concrete is provided by grout
injected in the ducts.
Bonded bar tendon, design QR-plate,
square and rectangular solid plates
10
Overview unbonded and external bar tendons
Unbonded and external bar tendons r estressed at any time and depending composite, steel, timber and masonry
are installed either inside or outside on the tendon type, they can also be structures.
the cross section of the structure. For removed or exchanged.
corrosion protection various systems The corrosions protection of unbonded
are available, all of which do not bond Internal unbonded and external tendons and external tendons depends on an
with the structure. The tendons may be are intended to be used for concrete, environmental conditions and service time.
Bar tendons with free tendon duct,
permanent corrosion protection executed
during grouting before stressing,
design square and rectangular solid plates
Bar tendons with free tendon duct,
permanent corrosion protection executed
by heatshrinking sleeve, design square and
rectangular solid plate
11
Geometrical characteristics of accessories
Threadbar Plain bar
Bar designation 26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
Domed anchor nut length [mm] 75 90 100 115 135 46 60
width across flat [mm] 50 60 65 70 80 55 65
Coupler (standard) length [mm] 170 200 210 245 270 110 160
outside diamter [mm] 50 60 68 70 83 60 68
Square solid plate width [mm] 150 180 200 220 260 - -
length [mm] 150 180 200 220 260 - -
thickness [mm] 35 40 45 45 50 - -
Rectangular solid plate width [mm] 130 140 150 160 - 140 150
(unbonded and bonded) length [mm] 150 180 220 250 - 180 220
thickness [mm] 35 40 50 60 - 40 50
QR-plate width [mm] 120 140 160 180 - - -
length [mm] 130 165 180 195 - - -
thickness [mm] 30 35 40 45 - - -
Corrugated duct internal diameter [mm] 38 44 51 55 65 44 51
outside diameter [mm] 43 49 56 60 70 49 56
Minimum bar protrusion [mm] 80 90 100 115 125 50 65
Rectangular solid plate width [mm] 120 140 160 180 - - -
(bonded) length [mm] 130 165 180 195 - - -
thickness [mm] 30 35 40 45 - - -
Overview of tensioning jacks for prestressing Tendons
Threadbar Plain bar
Bar designation 26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
60 Mp x x1 x1
110 Mp x x x x x x
200 Mp x
1 stressing force limited to 625 kN max.
12
Installation
DYWIDAG-SYSTEMS INTERNATIONAL
offers a full line of special installation
accessories to facilitate field assembly
and installation. Installation shall be
carried out by properly trained
and experienced personnel.
Tendons can be delivered to the jobsite
prefabricated when desired
(e.g. unbonded bar tendon), too.
Formwork
Value In the area of anchorage adequate
Grout Tube
space shall be accomplished through
a pocket former assembled at the
Pocket Former
formwork before concreting in order to
Retaining Nut put on the jack and for the grout cap.
Duct Duct Sleeve A Duct
Hex Nut Anchor Plate
Domed Anchor Nut
Stressing End
Woodrow Wilson Bridge, Washington, D.C., USA
Jeju Port Extension, South Korea
13
Stressing and grouting
The small, light and convenient- is pushed over a pull rod coupler that is anchor nut is tightened by an internal
ly operated DYWIDAG-SYSTEMS threaded onto the bar protrusion behind wrench. The bar 47 WR has a specially
INTERNATIONAL jacks facilitate the the domed anchor nut. The jack is then equipped stressing jack.
stressing operation. Heavy lifting aids fixed with a pulling nut. The tension load
are generally not necessary. The jack is hydraulically transferred. The domed
Stressing notes
Straight tendons are generally stressed
from one end only. In order to reduce
friction losses (especially in draped
tendons) it is recommended to stress
from both sides.
The prestressing load can be adjusted
up and down at any given time until
the tendon is fully grouted by simply
reinstalling the jack. This allows partially
stressing. Several controls during and
after the stressing operation check the
effective stressing load:
n bar protrusion at the anchorage To comply with exceptional high
efore and after stressing to evaluate
b demands on accuracy for example on
the effective elongation very short tendons special accessories
n counter control for elongation during can be applied to minimize the influence
stressing operation of alignment tolerances.
n gauge control for hydraulic pressure
Grouting
The durability of bonded post-tensioned
construction depends to a great degree
on the success of the grouting operation.
The hardened cement grout provides
bond between concrete and tensile
elements as well as primary long term
corrosion protection (alkaline medium)
for the prestressing steel.
DYWIDAG SYSTEMS INTERNATIONAL
has developed a grouting operation
that is based on highly plasticized grout
with thixotropic properties, and utilizes
durable grouting equipment. Advanced
methods such as pressure grouting,
post-grouting and vacuum grouting are
all results of many years of development.
Grouting is always done from a low-point
of the tendon. This can be one of the
anchorages with a grout cap with grout
inlet or along the tendon utilizing an
intermediate grout saddle. All grouting
components are threaded for easy, fast
and proper connection.
14
Ø
Ø
Ø
Equipment for stressing and grouting A B
Tensioning jacks
ØD
ØE
F
ØE
ØD
ØC
A B A B
L L
Tensioning jack 110 Mp/60 Mp Tensioning jack HOZ 200 Mp
Dimensions (for Block-Out design)
Tensioning jacks L X E stroke piston area Ak capacity max. piston weight A B X C X D F
pressure
[mm] [mm] [mm] [cm²] [kN] [bar] [kg] [mm] [mm] [mm] [mm] [mm]
ØD
ØE
60 Mp Series 04 401 190 50 132.5 625 50 36 225 176 3) 3) 300
60 Mp Series 05 456 190 100 132.5 625 50 44 225 231 3) 3) 300
110 Mp Series 01 494 267 50 235.6 1100 50 46 275 219 4) 4) 375
110 Mp Series 03 594 267
A 150 235.6
B 1100 50 54 275 319 4) 4) 375
200 Mp 865 315 150 361.3 2000 60 172 350 515 - 270 -
L
X C X D for type of bar
[mm] [mm]
3) 105 106 26 WR, 32 WS
135 114 32 WR
4) 122 106 26 WR
125 110 32 WS
125 120 32 WR, 36 WR/WS
134 134 40 WR
Hydraulic pumps
Hydraulic pumps Tensioning jacks
60 Mp 110 Mp 200 Mp
Pump Type 77-193 A Pump Type R 6.4
77-193 A n n
R 3.0 V n n
R 6.4 n n n
Pump type max. operating oil flow rate usable weight dimensions
pressure oil capacity with oil1 LxWxH
[bar] [l/min] [l] [kg] [mm]
77-193 A 600 3.0 10 63 420x380x480
R 3.0 V 600 3.0 13 98 600x390x750
R 6.4 600 6.4 70 310 1400x700x1100
1) hydraulic pumps will be supplied without oil
Grouting equipment (mixing and pumping)
Grouting max. injection capacity weight dimensions
Mixer MP 2000-5
equipment pressure LxWxH
[bar] [l/h] [kg] [mm]
MP 2000-5 15 420 300 2000x950x1600
15
Austria Italy A ustria
DYWIDAG-SYSTEMS DYWIT S.P.A.
INTERNATIONAL GMBH Via Grandi, 68 A rgentina
Wagram 49 20017 Mazzo di Rho (Milano), Italy A ustralia
4061 Pasching/Linz, Austria Phone +39-02-93 46 87 1
Phone +43-7229-61 04 90 Fax +39-02-93 46 87 301 belgium
Fax +43-7229-61 04 980 E-mail: [email protected]
E-mail: [email protected] B osnia and her z egovina
www.alwag.com Netherlands
DYWIDAG-SYSTEMS B ra z il
DYWIDAG-SYSTEMS INTERNATIONAL B.V C anada
INTERNATIONAL GMBH Veilingweg 2
Teichweg 9 5301 KM Zaltbommel, Netherlands C hile
5400 Hallein, Austria Phone +31-418-57 89 22
Phone +43-6245-87 23 0 Fax +31-418-51 30 12 C olombia
Fax +43-6245-87 23 08 0 E-mail: [email protected]
E-mail: [email protected] www.dsi-nl.nl
C osta R ica
www.dywidag-systems.at C roatia
Norway
Belgium and Luxembourg DYWIDAG-SYSTEMS C z ech republic
DYWIDAG-SYSTEMS INTERNATIONAL A/S
INTERNATIONAL N.V. Industrieveien 7A D enmar k
Industrieweg 25 1483 Skytta, Norway E gypt
3190 Boortmeerbeek, Belgium Phone +47-67-06 15 60
Phone +32-16-60 77 60 Fax +47-67-06 15 59 estonia
Fax +32-16-60 77 66 E-mail: [email protected]
E-mail: [email protected] F inland
Portugal
DYWIDAG-SYSTEMS
F rance
France
DSI-Artéon INTERNATIONAL LDA G ermany
Avenue du Bicentenaire Rua do Polo Sul
ZI Dagneux-BP 50053 Lote 1.01.1.1 – 2B G reece
01122 Montluel Cedex, France 1990-273 Lisbon, Portugal
Phone +33-4-78 79 27 82 Phone +351-21-89 22 890 GUATEMALA
Fax +33-4-78 79 01 56 Fax +351-21-89 22 899 HONDURAS
E-mail: [email protected] E-mail: [email protected]
www.dywidag-systems.fr H ong Kong
Spain
Germany DYWIDAG SISTEMAS I ndonesia
DYWIDAG-SYSTEMS CONSTRUCTIVOS, S.A.
Avenida de la Industria, 4
I ran
INTERNATIONAL GMBH
Schuetzenstrasse 20 Pol. Ind. La Cantuena I taly
14641 Nauen, Germany 28947 Fuenlabrada (MADRID), Spain
Phone +49 3321 44 18 32 Phone +34-91-642 20 72 J apan
Fax +49 3321 44 18 18 Fax +34-91-642 27 10
E-mail: [email protected] E-mail: dywidag Korea
@dywidag-sistemas.com L ebanon
DYWIDAG-SYSTEMS www.dywidag-sistemas.com
INTERNATIONAL GMBH L u x embourg
Max-Planck-Ring 1 United Kingdom
40764 Langenfeld, Germany DYWIDAG-SYSTEMS M alaysia
Phone +49 2173 79 02 0 INTERNATIONAL LTD.
Northfield Road
M e x ico
Fax +49 2173 79 02 20
E-mail: [email protected] Southam, Warwickshire N etherlands
www.suspa-dsi.de CV47 OFG, Great Britain
Phone +44-1926-81 39 80 N orway
DYWIDAG-SYSTEMS Fax +44-1926-81 38 17
INTERNATIONAL GMBH E-mail: [email protected] O man
Germanenstrasse 8 www.dywidag-systems.com/uk P anama
86343 Koenigsbrunn, Germany
Phone +49 8231 96 07 0 P araguay
Fax +49 8231 96 07 40
E-mail: [email protected] P eru
POLAND
DYWIDAG-Systems
International GMBH P ortugal
Siemensstrasse 8
85716 Unterschleissheim, Germany Q atar
Phone +49-89-30 90 50-100 S audi A rabia
Fax +49-89-30 90 50-120
E-mail: [email protected] singapore
www.dywidag-systems.com
S outh A frica
S pain
S weden
S wit z erland
T aiwan
T hailand
Please note: T ur k ey
This brochure serves basic information U nited A rab E mirates
purposes only. Technical data and information
U nited k ingdom
provided herein shall be considered
04315-1/10.09-web st
non-binding and may be subject to change U ruguay
without notice. We do not assume any liability USA
for losses or damages attributed to the use
V ene z uela
of this technical data and any improper
use of our products. Should you require
further information on particular products,
please do not hesitate to contact us. www.dywidag-systems.com