MasterRoc® SLF20
Foaming agent for concrete milk, mortar and concrete
DESCRIPTION Heat-insulation products, ALC panels, etc,
particularly requiring fine surface.
MasterRoc® Fix SLF 20 is a foaming agent for Roof slabs, cap flashing and raising floor level
obtaining extremely uniform and highly entrained air
The substrate of waterproofing in decks roofs,
in stable and relatively independent foam. In case
balconies, etc., slab mortar and concrete on
where stable foam in cement milk is considered
the ground and the substrate of pedestrian
difficult, MEYCO FIX SLF 20 in proper dosage
deck.
enables to produce uniform and stable foam cement
Other various air-entrained cement and
milk. Moreover using Perlight, artificial lightweight
foamed mortar and concrete application.
aggregate (ALA) or other special materials, it
enables to produce economically excellent DOSAGE
lightweight, heat-insulting and sound absorbing Dosage varies considerably according to employed
foamed mortar and concrete. materials, temperature, mix-design, mixing
ADVANTAGES procedure, etc. Therefore, trial mix should be made
to determine the appropriate dosage.
Achieves excellent foaming performance not
only in cement milk but also mortar and HOW TO USE
concrete. Pre –Foamed Method
Improves plasticity and prevent materials
Dilute MEYCO FIX SLF 20 with water at ratio
segregation.
of 1:39
Reduces bleeding – consequently minimizes
Control amount of compressed air and flow of
sedimentation.
diluted MEYCO FIX SLF 20 in order to obtain
By varying the dosage rate, stable and appropriate optimum foam volume (Volume of
independent fine foam can be produced foam/Volume of dilutes MEYCO FIX SLF 20),
arbitrary (approx. 70% in cement milk, 60% in around 20-25 times.
mortar and 30% in concrete)
Introduce foam into either continuous mixer or
Produce fine surface hardened products with agitator truck directly and mix well with mortar
excellent properties of light weight, heat- or concrete. Then place foamed
insulation and sound absorbing, etc. mortar/concrete by pump, etc.
Suitable for either “Pre-Foamed” or “Ordinary Consult with local BASF Construction
Mixing” method Chemicals field representative about foaming
Maintain good working at tunnel, underground machine, etc. in detail.
jobs, etc. due to scentless agent.
Site
COMPONENTS & PHYSICAL PROPERTIES
Diluted Foaming
Main Component : Quality Alcohol and Sulfuric SLF20 Machine
Foam
Ester
Appearance : Pale yellow liquid
Freezing temperature (°C) : -1 High Speed Placement
Rotation
* Any chloride as a raw material is not Mix
composed.
PACKAGE Cement, Aggregate, Mortar/
Water Paste
200 kg drum
WHERE TO USE
All sort of lightweight filling for bank of tunnel
Ordinary Mix Method
entrance, expansion of roads, etc. (Refer “Foamed
Cement Banking Method” developed by Japan 1. Introduce undiluted MEYCO FIX SLF 20
Highway Public Corporation). into mixing water. In this case, amount of
MEYCO FIX SLF 20 should be counted
Back filling of tunnel lining, making flat subsoil as a part of mixing water.
on slopes, soft ground treatment, etc.
Filling various unused pipes, etc.
MasterRoc® SLF20
2. Mixing produce: Introduce aggregate
and cement into the mixer and then add
mixing water with MEYCO FIX SLF 20.
Mix well water for 1.2-1.5 times longer
period of ordinary mix.
RMC Plant
Diluted Mixing
SLF20 Water
Wet Mixer Truck
Plant Mixer
Cement,
Aggregate
PRECAUTIONS
1. Store MEYCO FIX SLF 20 under the conditions
where rainwater, other admixtures of foreign
matter are kept away from the containers and
keep temperature above its freezing point (-
1°C).
2. If, MEYCO FIX SLF 20 was frozen, heat gently
with mechanical agitation until complete
thawing before use.
3. Wear mask, protective eyeglasses, rubber
gloves, etc. at the handling.
4. First -Aid
(a) In case of contact with eye, immediately
washaway with water and then receive
medical treatment.
(b) In case of swallowing, drink lots of water
MasterRoc® SLF20
The technical information and application advice given in this BASF Construction Chemicals publication are based
STATEMENT OF on the present state of our best scientific and practical knowledge. As the information herein is of a general
RESPONSIBILITY nature, no assumption can be made as to a product's suitability for a particular use or application and no warranty
as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law.
The user is responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE
orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF Construction Chemicals, are responsible for carrying out procedures appropriate to a specific application.
PT BASF Indonesia
DBS Bank Tower 27th Floor
Ciputra World 1 Jakarta
Jl. Prof. Dr. Satrio Kav. 3-5
Jakarta 12940
Phone: +6221 29886000
Website: www.master-builders-solutions.basf.co.id