0% found this document useful (0 votes)
109 views

Design of Staircase - 3

The document provides design details for a staircase, including: 1) Design data such as material properties and load assumptions. 2) Dimensions for the going, rise, and span of the staircase steps and landings. 3) Calculations of loads on the going slab based on self-weight, finishes, and live loads. 4) Analysis of the maximum bending moment and calculation of the required reinforcement area and spacing for the going slab designed as a singly reinforced section.

Uploaded by

vinujohnpanicker
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views

Design of Staircase - 3

The document provides design details for a staircase, including: 1) Design data such as material properties and load assumptions. 2) Dimensions for the going, rise, and span of the staircase steps and landings. 3) Calculations of loads on the going slab based on self-weight, finishes, and live loads. 4) Analysis of the maximum bending moment and calculation of the required reinforcement area and spacing for the going slab designed as a singly reinforced section.

Uploaded by

vinujohnpanicker
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DESIGN OF STAIRCASE-3 0.3 0.

05
0.3
0.12

0.3

0.15

1) Design Data
2
Concrete density= 25 kN/m
Condering 1 m length
Area 0.174 m2
Dead load= 4.35 kN/m2
SIDL= 1.2 kN/m2
Live load= 5 kN/m2
Concrete Grade= 30 KN/mm2
Steel Grade= 500 KN/mm2

2) Design of going and landing slab

Tread= 300 mm
Rise= 150 mm
Span= 3650 mm

c/c distance of b/w landing= 3650 mm

Assume total depth of waist slab,D 120 mm
Assume Cover, d= 20 mm
Reinforcement Main Bar Dia(T)= 12 mm
Effective Depth=‐ 94 mm
Assume depth of landing slab= 120 mm
Effective Depth=‐ 94 mm
Width,b = 1000 mm
3) Load Calculation

Loads on going (on projected plan area)

(a)  Self‐weight of folded slab 4.35 kN/m2


(c) Finishes 1.2 kN/m2
(d) Live Loads 5 kN/m2
Total factored loads = 15.825 kN/m2
4) Analysis and Design

2
Max BM= wl /8 26.35357 kNm

Ru = 3.99

= 81.27057 mm

√  

Provided D= 120 mm d= 94 mm
b= 1000 mm
Designing as singly reinforced section
2
Ast 742.596 mm
Main Reinforcement
Assume 12 mm dia  bar
2
Ast12 113.0973 mm
Spacing = 152.2999
150 mm c/c

12 mm  bar  150 mm c/c


Distribution Reinforcement
2
Asd 0.0012 144 mm

Provide  8 mm @ 300 mm c/c