Catalogo Eletrodos de Ions Seletivos Thermo Orion c10b753192
Catalogo Eletrodos de Ions Seletivos Thermo Orion c10b753192
www.thermoscientific.
     com/waterlibrary
for more product information.
            Thermo Scien
                   Scientific Orion Ion Selective Electrodes
            Ion Selective Electr
                          Electrodes (ISE) are easy to use and provide you the best performance and reliability
              Compared to other methods such as atomic absorption or ion                   Plastic Membrane Half-Cell ISE
                                                                                                                                                  Nitrate, Potassium,
              chromatography, there is a small setup cost and it does not require          PVC body
                                                                                                                                                  Calcium, Ammonium,
              additional expensive readout equipment. Sample color or turbidity            Require separate reference                             Fluoroborate
                                                                                           Temperature range 0-40 ºC
              do not affect the measurement.
                                                                                           ROSS® Half-Cell ISE
              Measurement Techniques                                                       Glass body
                                                                                                                                                  Sodium
              Direct Measurement is a simple procedure for measuring a                     Requires ROSS half-cell reference
              large number of samples. Each sample only requires one reading.              Temperature range 0-100 ºC
              Only a small sample volume is required. Calibration is performed
              on a series of standards. The concentration is then determined by            Combination Ion Selective Electrodes
                                                                                           Sure-Flow® Reference makes electrode easy to clean and long lasting
              comparison to the standards. Ionic strength adjustor is added to
                                                                                           Ionplus® Sure-Flow® Combination ISE                    Fluoride, Chloride,
              all solutions to ensure samples and standards have similar ionic             Epoxy body
                                                                                                                                                  Cyanide, Silver-Sulfide,
                                                                                                                                                  Lead, Bromide,
              strength, proper pH and reduce the effect of interfering ions.               Temperature range 0-80 ºC                              Cadmium, Cupric, Iodide
              Orion ISE meters calculate and store the calibration curves.
                                                                                           Ionplus Sure-Flow Combination Plastic Membrane ISE
                                                                                                                                                  Nitrate, Potassium,
              Low Level Measurement is a similar method to direct                          PVC body
                                                                                                                                                  Calcium
                                                                                           Temperature range 0-40 ºC
              measurement. It is recommended when the sample is not in
              the linear response range. A minimum 3 point calibration is                  ROSS Sure-Flow® Combination ISE
              recommended to compensate for the non-linear response.                       Glass body                                             Sodium
                                                                                           Temperature range 0-100 ºC
              Calibration is performed in one beaker reducing the chance of
              cross contamination of the standards.
                                                                                           Various ISE Applications
              Know Addition is a useful method for measuring samples since                 Agriculture
                                                                                                                 Nitrate, chloride, ammonia, potassium, calcium,
                                                                                                                 iodide, cyanide in soil, fertilizer and fedstuffs
              calibration is not required. This method is recommended when
                                                                                                                 Calcium, carbon dioxide and ammonia in biological
              measuring only a few samples, when samples have a high ionic                 Biomedical
                                                                                                                 cultures (not in vitro or in vivo)
              strength (>0.1 M) or when there is a complicated background                  Dairy Products        Chloride, fluoride, iodide, calcium, potassium
              matrix. An aliquot of standard solution containing the measured              Dental                Fluoride, calcium in teeth and toothpaste
              species is added to the sample. The sample concentration is                  Education             Various ISEs in teaching and research labs
                                                                                           Food & Beverage       Chloride, nitrate, sodium, calcium, potassium
              determined by the changes in potential before and after the
                                                                                           Geology               Fluoride and calcium in rocks
              addition. Orion ISE meters automatically calculate the result.
                                                                                           Metal Plating         Fluoride, copper, cyanide, chloride
              Analate Subtraction is also a useful method for measuring                                          Nitrate, chloride, fluoride, iodide, cyanide, calcium,
                                                                                           Plant Tissue
                                                                                                                 potassium and sodium
              samples since calibration is not required. The electrodes are                Power, Steam
                                                                                                                 Chloride, sodium and residual chlorine in boiler feeds
              immersed in a reagent solution that contains a species that the              Generators
              electrode senses and then it reacts with the sample. It is useful            Pulp and Paper        Sodium, chloride, sulfide and calcium in liquors
                                                                                                                 Nitrate, calcium, sodium, potassium, bromide,
              when sample size is small, for samples for which a standard is               Soil
                                                                                                                 chloride, ammonia, fluoride
              difficult to prepare, and for viscous or very concentrated samples.                                Nitrate, residual chlorine, fluoride, cyanide,
                                                                                           Water, Drinking
              The method is not suited for very diluted samples. It is also                                      sulfide, ammonia
                                                                                           Water, Sea            Sodium, chloride, fluoride, nitrate, ammonia
              necessary to know the stoichiometric ration between sample
                                                                                           Water, Waste          Nitrate, ammonia, residual chlorine, sulfides
              and standard.
                                                                                           Wine                  Potassium, sodium, fluoride, calcium
                                                                                       Key Information
                            1                2                     3                   1 BNC Waterproof Connector 2 BNC Connector
                                                                                       3 Screw Cap Connector, requires separate cable
                                                                                       8 Module only, requires separate 93 series electrode handle (9300BNWP or 9300SC)
                                                                                       All cap diameters are 16 mm at bottom of cap
                                BNC              BNC Connector         Screw Cap       All cable lengths are 1 meter
                                               Approved ASTM Method for Fluoride                                              Convenient                       Half cell reference design
                                               in Drinking Water and Wastewater                                               combination                      provides flexibility
                                                                                                                              with reference
                                               Analyze free fluoride ions in aqueous
                                               solutions reliably at low limits of detection.
                                               Measurements are quick, simple, accurate
                                               and economical.                                                                                                                    BEST                    BEST
                                               The Easy Way to Measure Nitrate                                              Convenient         Half cell reference design
                                               Levels in Drinking Water, Wastewater                                         combination        provides flexibility
                                                                                                                            electrode with
                                               and Soils
                                                                                                                            replaceable module
                                               Analyze free nitrate ions in aqueous
                                               solutions reliably at low limits of detection.
                                               Measurements are quick, simple, accurate                                                                                 BEST                               BEST
                                               and economical.
                                               Choose from combination electrodes                                                              BEST
                                                                                                                              and is easy
                                                                                                                              to clean
                                                                                                                            • Convenient
                                                                                                                              with small
                                                                                                                              sample sizes
  durability of electrode.
  Other Applications for                                                                           BEST
  Chloride Electrodes
  • Salt: Multiple known addition can
    be used to determine salt levels in
    food samples
  • Hydrochloric Acid: First
    derivative titration can determine
    HCl concentrations
  Accessories and Solutions
  Thermo Scientific offers a full line
  of accessories to enhance your
  measurements. These include calibration
  standards, two ionic strength adjustors                                          Combination
                                                                                   Combin
                                                                                   Com  bi ati
                                                                                        bin ation
                                                                                            at on
                                                                                               on                 Half
                                                                                                                  Hal
                                                                                                                  H alflf cell
                                                                                                                          ccells
                                                                                                                            elllss - Ch
                                                                                                                            ell      Chlor
                                                                                                                                     Chloride
                                                                                                                                        lo ide
                                                                                                                                        lor id IS
                                                                                                                                               ISE
                                                                                                                                                SE aand
                                                                                                                                                     nd dou
                                                                                                                                                        double ju
                                                                                                                                                        double junct
                                                                                                                                                               junction
                                                                                                                                                                  nction
                                                                                                                                                                  nct ion
  – one to adjust background ionic                                                 chloride
                                                                                   chl
                                                                                    hlori
                                                                                      oriide ISE
                                                                                              SE                  Sure-Flow
                                                                                                                  Sure-F
                                                                                                                  Sur   ee-FFlow
                                                                                                                            Flow re refer
                                                                                                                                    reference
                                                                                                                                      f enc
                                                                                                                                      fer ence
  strength (ISA) and another to minimize                                           with Sure   Flow®
                                                                                        Sure-Flow
                                                                                   reference                      • Double junction reference isolates inner
  complexation interferences and adjust                                                                             reference from sample
  background ionic strength (CISA), and                                            • Durable reference            • Designed for precision measurements
  choice of fill solutions depending on                                              pellet which can
                                                                                     be polished to
  sample composition.                                                                restore electrode
                                                                                     performance
                                                                                   • Sure-Flow
                                                                                     reference provides
                                                                                     easy maintenance
                                                                                     and optimum
                                                                                     performance
                                                                                                                  9417BN
                                                                         Cat. No. 9617BNWP                        9417SC                         900200
                                                                              5 x 10-5 to 1.0 M                   5 x 10-5 to 1.0 M
                                                            Measurement Range                                                                    –
                                                                              1.8 to 35,000 ppm                   1.8 to 35,000 ppm
                                                                    Temp. Range 0 to 80 °C                        0 to 80 °C                     0 to 100 °C
                                                                                                                  BNC
                                                                 Connector Type BNC Waterproof                                                   Pin Tip
                                                                                                                  Screw cap
                                               Comes with Complete Solution Kit                                              Convenient                    Half cell reference design
                                               Containing Standards, Reagents,                                               combination                   provides flexibility with choice
                                               ISA and More!                                                                 with Sure-Flow                of ROSS references
                                                                                                                             reference
                                               Quick, accurate and economical
                                               measurements of free sodium ions in
                                               aqueous solutions. Chemical resistant                                                                                         BEST                           BEST
                                               glass body.
                                               Applications for Sodium Electrodes                                                             BEST                          SUPERIOR
                                                                                                                                                                          TEMPERATURE
                                                                                                                                                                                                           SUPERIOR
                                                                                                                                                                                                         TEMPERATURE