0% found this document useful (0 votes)
2K views2 pages

Synchronous Timer Series EM 1000 - GIC INdia

The document describes an asynchronous timer device. It provides timing ranges from 0.15 seconds to 120 hours and can operate from 110V AC to 240V AC power sources. It has outputs for one instant contact and one delayed contact or two delayed contacts. The timer has a base or flush mounting option and features like automatic reset and no-volt operation.

Uploaded by

PrasadPurohit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

Synchronous Timer Series EM 1000 - GIC INdia

The document describes an asynchronous timer device. It provides timing ranges from 0.15 seconds to 120 hours and can operate from 110V AC to 240V AC power sources. It has outputs for one instant contact and one delayed contact or two delayed contacts. The timer has a base or flush mounting option and features like automatic reset and no-volt operation.

Uploaded by

PrasadPurohit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

6\QFKURQRXV7LPHU6HULHV(0

‡7LPHGHOD\LVLQGHSHQGHQWRIQRUPDOYROWDJHDQGWHPSHUDWXUHIOXFWXDWLRQV
‡%ODFNSRLQWHUJLYHVFOHDULQGLFDWLRQRIWKHWLPHVHWRQWKHFDOLEUDWHGGLDO
ZKLOHWKHUHGRQHLQGLFDWHVWKHWLPHOHIWWRFRPSOHWHWKHF\FOH
‡$XWRPDWLFUHVHWRQGHHQHUJLVDWLRQRIWKHFOXWFKFRLO
‡%DVHPRXQWLQJRUIOXVKPRXQWLQJYHUVLRQV
‡1RYROWIHDWXUHDYDLODEOH

Ordering Information
Timing Ranges(SR) %

%  6(& Delay


&  6(&  6WDQGDUG21GHOD\
'  0,1  :LWKµ1292/7¶
(  0,1
)  +56
*  +56 Mounting
+  6(&
% %DVH0RXQWLQJ
-  6(&
) )OXVK GRRU 0WJ
.  0,1
/  0,1 Contact
0  +56 Timing Ranges(MR) ,QVW'HO&2
1  +56 ,QVW'HO&2
3  6(&
; 6(&+56 Voltage
4  6(& < 6(&+56 9$&+]
5  0,1 = 6(&+56 9$&+]
6  0,1 &9$&+]
7  +56 '9$&+]
9  +56

46
6\QFKURQRXV7LPHU6HULHV(0

Mode ON Delay ON Delay Retentive (No Volt)


)XQFWLRQDO'LDJUDP

  

 

6XSSO\9DULDWLRQ WR
)UHTXHQF\9DULDWLRQ WR
3RZHU&RQVXPSWLRQ 0D[ 9$&
7LPLQJ5DQJH VWRK
5HSHDW$FFXUDF\ “RI)XOO6FDOH5DQJH#&RQVWDQW)UHTXHQF\
2XWSXW&RQWDFW ,QVWDQW'HOD\HG,QVWDQW'HOD\HG 2SWLRQDO
2XWSXW &RQWDFW5DWLQJ $ UHVLVWLYH #9$&
6ZLWFKLQJ)UHTXHQF\ RSHUDWLRQVKU 0D[
2SHUDWLQJ7HPSHUDWXUH ƒ&WRƒ&
(QFORVXUH &RQIRUPVWR,3,6
'LPHQVLRQ :[+['  LQPP ;;
:HLJKW XQSDFNHG  J
0RXQWLQJ )OXVK%DVH
7HUPLQDO&RQQHFWLRQ ±PPðVROLGVWUDQGHG
'HJUHHRI3URWHFWLRQ ,3

MOUNTING DIMENSION (mm)


   

       

   

  


)


B C D

( '


,

&
'

?
% %

.
-

/ 0 1 0 2 3 4 5 1 6 7 8 9 2 5 3 4 : ; 1 9 2 ; 4

=     >   <

! "

 < <


  

# $

  

! "

%$6(',102817,1*

CONNECTION DIAGRAM TERMINAL TORQUE & CAPACITY

&OXWFK ,QVWDQW 0RWRU 'HOD\ N O P N Q O R S T O U V W O X Y Z

‘
 G H I I G G G G H G J I I

        \ ] \ O ^ R R
[

_ ` a X b c _ d e f Y b g b L X e g

\ ] \ N d ` U h

K L M

    

47

You might also like