ASCO MP-C-080 Solenoid Valve Datasheet
ASCO MP-C-080 Solenoid Valve Datasheet
SOLENOID VALVES
redundant, direct operated U 1
3 Series
basic flow, balanced poppet 327
1/4 2
FEATURES
• The redundant solenoid valves are recommended for fail safe pilot applications
combining high flow, wide pressure range and absence of minimum operating
pressure
• When the redundant valve controls an actuator, the actuator remains in position
as long as one of the two solenoid valves (coils) is energized. To exhaust the
actuator both solenoids have to be de-energized
• PTFE rider rings and graphite-filled PTFE seals reduce friction and eliminate
sticking
• Coils used in metal enclosures have class H insulation materials
• Dedicated execution for low power
• Dedicated execution for extreme low ambient temperatures
• Peak voltage suppression diodes are standard in DC solenoids with metal
enclosures
• The solenoid valves satisfy all relevant EC Directives
• Environmental NACE compliant and certified vibration resistant in combination
with WSCR solenoids
GENERAL
Differential pressure 0 - 10 bar [1 bar = 100kPa]
Maximum viscosity 65cST (mm2/s)
Response times 75 - 100 ms (1)
fluids(2) () temperature range (TS)(3) seal materials () 1
-20 to +120°C FPM (fluoroelastomer)
air, inert gas, water, oil -40 to +40°C VMQ (silicone) 3
-60 to +60°C (F)VMQ ((fluor)silicone) 2
(1)
Energising time for Ex i version booster coils will be < 2 sec (NFIS, WSNFIS and WSCRIS)
(2)
Air / inert gas only for Ex i version (NFIS, WSNFIS and WSCRIS)
(3)
Can be limited by the operator ambient temperature range for explosion proof solenoids
(2)
Standard prefixes/suffixes are also applicable to kits (3)
Prefix EF and EV should always be used in conjunction with change
Mounting holes in body letter H in the basic number
(4)
Basic kit number applies to SC coil construction
¬
Because of the nature of redundant valves (2x solenoid) the
spare part kits have to be ordered 2x
ELECTRICAL CHARACTERISTICS
Coil insulation class H(1)/ F(2)
Electrical safety IEC 60335-1
Standard voltages DC (=) 24V - 48V; Allowable voltage variation ± 10%
AC (~) 24V - 48V - 115V - 230V/50/60Hz; Other voltages are available on request
power ratings operator
ambient electrical replacement coil / kit
prefix inrush holding hot/cold temperature enclosure
safety code
option ~ ~ = range protection ~ = type(4)
(VA) (VA) (W) (W) (C°)(3) (EN 60529)
230V/50/60 Hz 24V/DC
Basic power (BP)
SC 10,0 10,0 10,0 9,0/11,2 -40 to +55 EN 60730 IP65, moulded 123664-017 400425-142 01
WP/WS 10,0 10,0 10,0 9,0/11,2 -40 to +55 EN 60730 IP67, steel /SS 400915-017 400913-142 03
NF/WSNF 10,0 10,0 10,0 9,0/11,2 -60 to +40/60 II2G Ex db IIC Gb T6/T5, II2D Ex tb IIIC Db IP66/67, alu./SS 400915-017 400913-142 05
EM/WSEM 10,0 10,0 10,0 9,0/11,2 -40 to +40 II2G Ex eb mb IIC Gb T3, II2D Ex tb IIIC Db IP66/67, steel /SS 400915-017 400913-142 03
PV - - - 9,0/11,2 -40 to +55 II2G Ex mb IIC Gb T4, II2D Ex mb IIIC Db IP67, moulded - - (5) 07
EF/EV 12,0 12,0 12,0 9,3/11,6 -40 to +52/40 NEMA type 7 and 9 NEMA 4X 276002-058D 238714-006D 08
Medium Power (MP)
SC 5,8 5,8 5,8 5,2/5,7 -40 to +90 EN 60730 IP65, moulded 400924-297 400923-442 02
WP/WS 5,8 5,8 5,8 5,2/5,7 -40 to +90 EN 60730 IP67, steel /SS 400921-297 400914-442 04
NF/WSNF 5,8 5,8 5,8 5,2/5,7 -60 to +40/75 II2G Ex db IIC Gb T6/T5/T4, II2D Ex tb IIIC Db IP66/67, alu./SS 400921-297 400914-442 05
WSCR 5,8 5,8 5,8 5,2/5,7 -60 to +90 II2G Ex db IIC Gb T6/T4, II2D Ex t IIIC Db IP66/67, SS 400962-297 400961-442 06
WSCREM 5,8 5,8 5,8 5,2/5,7 -60 to +60/75/90 II2G Ex eb mb IIC Gb T6/T4, II2D Ex tb IIIC Db IP66/67, SS 400962-297 400961-442 06
EM/WSEM 5,8 5,8 5,8 5,2/5,7 -40 to +40/75 II2G Ex eb mb IIC Gb T5/T4, II2D Ex tb IIIC Db IP66/67, steel /SS 400921-297 400914-442 04
Reduced Power (RP)(6)
SC 3,7 3,7 3,7 3,2/3,6 -40 to +55 EN 60730 IP65, moulded - (6) 400923-042 02
WP/WS 3,7 3,7 3,7 3,2/3,6 -40 to +55 EN 60730 IP67, steel /SS - (6) 400914-242 04
NF/WSNF 3,7 3,7 3,7 3,2/3,6 -60 to +60 II2G Ex db IIC Gb T6, II2D Ex tb IIIC Db IP66/67, alu./SS - (6) 400914-242 05
WSCR 3,7 3,7 3,7 3,2/3,6 -60 to +40/60/90 II2G Ex db IIC Gb T6/T5/T4, II2D Ex t IIIC Db IP66/67, SS - (6) 400961-242 06
WSCREM 3,7 3,7 3,7 3,2/3,6 -60 to +40/60/90 II2G Ex eb mb IIC Gb T6/T5/T4, II2D Ex tb IIIC Db IP66/67, SS - (6) 400961-242 06
EM/WSEM 3,7 3,7 3,7 3,2/3,6 -40 to +40/55 II2G Ex eb mb IIC Gb T6/T5, II2D Ex tb IIIC Db IP66/67, steel /SS - (6) 400914-242 04
Low Power (LP)(7)
NF/WSNF 1,85 1,85 1,85 1,5/1,8 -60 to +55 II2G Ex db IIC Gb T6, II2D Ex tb IIIC Db IP66/67, alu./SS - (7) 400914-542 05
WSCR 1,85 1,85 1,85 1,5/1,8 -60 to +55 II2G Ex db IIC Gb T6, II2D Ex t IIIC Db IP66/67, SS - (7) 400961-542 06
WSCREM 1,85 1,85 1,85 1,5/1,8 -60 to +55 II2G Ex eb mb IIC Gb T6, II2D Ex tb IIIC Db IP66/67, SS - (7) 400961-542 06
NFIS (8) (9) 0,5 0,5 0,5 0,5 -40 to +60 II2G Ex ia IIC T6 Gb, II2D Ex tb IIIC Db IP66/67, alu./SS - (7) 429013-001 05
WSCRIS (9) 0,5 0,5 0,5 0,5 -40 to +60 II2G Ex ia IIC T6 Gb, II2D Ex tb IIIC Db IP66/67, SS - (7) 429013-001 06
WSNFIS (9) 0,5 0,5 0,5 0,5 -40 to +60 II2G Ex ia IIC T6 Gb, II2D Ex tb IIIC Db IP66/67, alu./SS - (7) 429013-001 05
(1)
Coils used in metal enclosures have class H insulation materials (2)
Encapsulated (open) coils have class F insulation standard Temperature range can be limited by sealings
(3)
(4)
Refer to the dimensional drawings on page 4 and 5 (5)
Multiple coil kits are available under ATEX/IECEx, contact us AC limited to 127V/50/60Hz or 125V/DC
(6)
(7)
Only available in 24V/DC (8)
Shall be protected against any impact or friction, see the For safety and nominal electrical parameters refer to applicable
(9)
- Not available installation conditions given in the I&M sheet solenoid page or I&M sheet
ELECTRICAL CONNECTIONS
prefix connection
SC Spade plug connector with cable gland EN175301-803A (ISO 4400) for cables
with an outer diameter from 6 to 10 mm
WP, WS, EM, WSEM, NFIS, WSNFIS, WSCRIS M20 plastics cable gland for cables with an outer diameter from 7 to 12 mm.
WSCREM M20 316 SS cable gland for cables with an outer diameter from 7,2 to 11,7 mm.
NF, WSNF, WSCR, NFTIS, WSNFTIS 1/2" NPT threaded cable entry. Enclosures are supplied without cable gland
NFET, WSNFET, NFETIS, WSNFETIS M20 x 1,5 threaded cable entry. Enclosures are supplied without cable gland
80402GB-2018/R01
ADDITIONAL OPTIONS
● Direct mount / pad mount construction according to NAMUR recommendations
● Ex mb/mD (prefix "PV") solenoid can be supplied with various cable lengths
● Compliance with "UL", "CSA" and other local approvals available on request
● Special moulded-in solid state components for peak voltage suppression and/or rectification (four diode bridge)
● -60°C execution available on request
● Class H insulation for encapsulated coils
● Material certification like EN 10204 3.1 on the 316L Stainless Steel bodies are available on request
INSTALLATION
● Multi language installation/maintenance instructions are included with each valve
● The solenoid valves can be mounted in any position without affecting operation
● The mounting holes are provided in the valve body
● Threaded pipe connection identifier is 8 = NPT (ANSI 1.20.3); G = G (ISO 228/1)
● Declarations of conformity are available on request
● Ex eb mb Prefix "EM" and Ex ia Prefix "NFIS/WSCRIS" execution: solenoid enclosure has a cable gland with integral strain
relief for cables with an o.d. from 7 to 12 mm and housing is provided with an internal and external connection facility for an
earthing or bonding conductor
● E
x db Prefix "NF/WSNF/WSCR" enclosure is provided with a 1/2" NPT threaded entry hole, M20 x 1,5 (prefix "ET") is optional.
327B051 / B052 / B061 / B062 327B151 / B152 / B161 / B162 / B251 / B252 / B261 / B262
360° 360°
327B051 / B052 / B061 / B062 327B151 / B152 / B161 / B162 / B251 / B252 / B261 / B262
360°
360°
80402GB-2018/R01
327 B051 / B052 / B061 / B062 / B151 / B152 / B161 / B162 / 327 B152 / B162 / B252 / B262 / B352 / B362
B251 / B252 / B261 / B262 / B351 / B352 / B361 / B362
A D
E
B G
F 1
C
Ø5,5
3
H
2
12
36
27
37
SECTIONAL DRAWING
A
3
1
Schematic presentation of
3 the redundant valve
2
NF/WSNF
MOUNTING BRACKET
PIC-12-0010-GB -- Availability, design and specifications are subject to change without notice. All rights reserved.
Bracket kit no.: C139824
contains: Stainless steel
304 SS screws and bracket
80402GB-2018/R01