0% found this document useful (0 votes)
563 views152 pages

Mitsubishi MR Slim Split

The document is a product catalogue from Mitsubishi Electric that provides specifications for their VL-100EU5-E split-type air conditioner model. Key details include that it operates on 220-240V power at 50 or 60Hz, has adjustable fan speeds from 55-106m3/h, power consumption between 13-34W, noise levels between 72-80dB, and weighs 7.5kg. Installation instructions warn against using unapproved refrigerants or allowing air in the refrigerant lines.

Uploaded by

Zeeshan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
563 views152 pages

Mitsubishi MR Slim Split

The document is a product catalogue from Mitsubishi Electric that provides specifications for their VL-100EU5-E split-type air conditioner model. Key details include that it operates on 220-240V power at 50 or 60Hz, has adjustable fan speeds from 55-106m3/h, power consumption between 13-34W, noise levels between 72-80dB, and weighs 7.5kg. Installation instructions warn against using unapproved refrigerants or allowing air in the refrigerant lines.

Uploaded by

Zeeshan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 152

SPLIT-TYPE

YPE AIR COND


CONDITIONERS
DITION Full Product Line Catalogue 2014
14
NOTICE
■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the
refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Eco Changes is the Mitsubishi Electric Group’s environmental statement,


Wrap Yourself in Comfort and Quiet
and expresses the Group’s stance on environmental management. Eco-conscious Technologies from Japan
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.

Full Product Line Catalogue

2014
Revised publication effective Jan. 2014.
Superseding publication of S-179-3-C9236-B Jul. 2013.
S-179-3-C9236-B SI1401 Printed in Japan (MDOC) Specifications are subject to change without notice.

cover_F.indd 1 13.12.12 1:14:49 PM


VL-100EU5-E
Supply Power line Power Temp.exchange
Fan Air volume Noise Weight
voltage frequency consumption efficiency
speed (m3/h) (dB) (kg)
(V) (Hz) (W) (%)
HI 100 30 73 36.5
220 50
LO 55 13 80 24
HI 105 31 73 37
230 50
LO 60 15 80 25 7.5
HI 106 34 72 38
240 50
LO 61 17 79 27
HI 103 34 73 38
220 60
LO 57 17 80 25

(ADJUSTABLE)
MOUNTING PLATE REQUIRE TO BE SECURED
REQUIRE TO BE SECURED

13.5
EDGE OF MAIN UNIT 420

40

from nearest
obstruction
PITCH 20X10=200

183min
119
95.5

238.5
25

265
15
87
97

95
108
MOUNTING HOLES

233min
36×ø6

(ADJUST (ADJUST

25
75 ABLE) 200(MIN) 75 ABLE)
350(MAX)
POWER CORD HOLE
267.5 292
AIR EXHAUST HOLE 530 AIR INTAKE HOLE
ø85 to ø90 WALL HOLE 554 ø85 to ø90 WALL HOLE
620
360min from nearest obstruction 360min

FRONT PANEL
(OPEN POSITION)

12
INDOOR AIR EXHAUST

OUTER DIA
A
OUTER DI
FRONT PANEL

ø79×2
ø75×2
(CLOSED POSITION)

FRONT PANEL LOUVER


(VERTICAL POSITION)

ø150

FRONT PANEL LOUVER
(HORIZONTAL POSITION)

90 140 22 17
FRESH AIR SUPPLY
54 WALL THICKNESS
620 226 200 50 to 550 106

SHUTTER KNOB SHUTTER KNOB

Doing Our Part to


(CLOSED POSITION) (OPEN POSITION) Unit: mm

VL-100U5-E
Supply Power line Power Temp.exchange

Create a Better Future for All...


Fan Air volume Noise Weight
voltage frequency consumption efficiency
speed (m3/h) (dB) (kg)
(V) (Hz) (W) (%)
HI 100 30 73 36.5
220 50
LO 55 13 80 24
HI 105 31 73 37
230 50
LO 60 15 80 25 7.5
Core Environmental Policy 240 50
HI 106 34 72 38
LO 61 17 79 27
HI 103 34 73 38
220 60
The Mitsubishi Electric Group promotes sustainable development and is LO 57 17 80 25

committed to protecting and restoring the global environment through technology,

(ADJUSTABLE)
MOUNTING PLATE REQUIRE TO BE SECURED
REQUIRE TO BE SECURED
through all its business activities, and through the actions of its employees.

13.5
EDGE OF MAIN UNIT 420

40

from nearest
obstruction
PITCH 20X10=200

183min
119
95.5

238.5
25

265
Environmental Vision 2021

15
87

95
108
MOUNTING HOLES

233min
36×ø6

(ADJUST (ADJUST
75 ABLE) 200(MIN) 75 ABLE)
350(MAX)
267.5 292
AIR EXHAUST HOLE 530 AIR INTAKE HOLE
ø85 to ø90 WALL HOLE 554 ø85 to ø90 WALL HOLE
620
360min from nearest obstruction 360min

Making Positive Contributions to the Earth FRONT PANEL


(OPEN POSITION)
and its People through Technology and Action

12
INDOOR AIR EXHAUST

OUTER DIA
A
OUTER DI
FRONT PANEL

ø79×2
ø75×2
(CLOSED POSITION)

FRONT PANEL LOUVER


(VERTICAL POSITION)

ø150

Preventing Global Warming Creating a Recycling-Based Society FRONT PANEL LOUVER
(HORIZONTAL POSITION)

●Reduce CO 2 emissions from product usage by 30% ●Reduce, reuse and recycle “3Rs” products 90 140 17
FRESH AIR SUPPLY 22
●Reduce total CO 2 emissions from production by 30% reduce resources used by 30% 252 175 54 WALL THICKNESS
●Aim to reduce CO 2 emissions from ●Zero emissions from manufacturing reducing 620 226 200 50 to 550 106

power generation the direct landfill of waste to zero SHUTTER KNOB SHUTTER KNOB
(CLOSED POSITION) (OPEN POSITION) Unit: mm

Ensuring Harmony with Nature Fostering Environmental Awareness

1 150
Mitsubishi Electric reflects the essence of this policy and vision
in all aspects of its air conditioner business as well.

Preventing Global Warming


Heat pump technology inspires Mitsubishi Electric to design air conditioners
that harmonize comfort and ecology.

Heat Pump Principle (When Heating) <Case of COP 5.0>


Refrigerant and Heat Circulation

“1kW”
Electrical
Energy Input Compressor compresses
refrigerant to raise
the temperature
10oC 80oC

o o
20 o
60 C Compressor 60 C
Outdoors Indoors

“4kW” “5kW”
Heat absorbed Heat output
Evaporator Condenser
from the air
Expansion valve
o
o
30 C 40 C
o o
5C 50 C
Heat
Expansion valve expands
refrigerant to lower the temperature

Output energy is quintuple of input energy

“1kW” “4kW” “5kW”


Electrical Energy Input Heat Absorbed from the air Heat Output

Mitsubishi Electric develops technologies to balance comfort and ecology,


achieving greater efficiency in heat pump operation.

Comfort Ecology

1. Inverter Faster start-up and more Fewer On/Off operations


stable indoor temperature than with non-inverter, saving
than non-inverter units. energy.

2. i-see Sensor Monitoring the temperature Optimum control of the airflow to


gaps between the floor and prevent excessive compressor
the set temperature to prevent operation for more efficient
deficient warming. heating operation.

3. Flash Injection Achieves high heating Expands the region covered by


capacity even at low heat pump heating system.
temperatures, plus faster
start-up compared to
conventional inverters.

Creating a Recycling-Based Society

1. All models are designed for RoHS and WEEE compliance. *


2. Mitsubishi Electric develops downsizing technology to reduce materials use.
- PUHZ-RP200/250YKA2: Volume reduction approx. 60% compared to PUHZ-RP200/250YHA
* WEEE and RoHS directives: The Waste Electrical and Electronic Equipment (WEEE) Directive is a recycling directive for this
type of equipment, while the Restrictions of Hazardous Substances (RoHS) Directive is an EU directive restricting the use of six
specified substances in electronic and electrical devices. In the EU, it is no longer possible (from July 2006) to sell products
containing any of the six substances.

Ensuring Harmony with Nature / Fostering Environmental Awareness

In striving to heighten the eco-awareness of its employees, Mitsubishi Electric provides


education in RoHS, WEEE and other environmental regulations, along with environmental
education targeting second and third-year workers.

P002.indd 2 13.12.12 1:15:41 PM


C
ONTENTS

P003-028.indd 3 13.12.12 1:17:04 PM


Air Conditioners

LINE-UP 005-008

NEW ECODESIGN DIRECTIVE 009-010

INVERTER TECHNOLOGIES 011-012

FEATURES 013-018

FUNCTION LIST 019-022

CONTROL TECHNOLOGIES 023-028

M SERIES 029-048

S SERIES 049-054

P SERIES 055-080

POWERFUL HEATING SERIES 081-092

MXZ SERIES 093-098

OPTIONAL PARTS 099-104

EXTERNAL DIMENSIONS 105-118

PIPING INSTALLATION 119-124

AIR-TO-WATER

FEATURES & SPECIFICATIONS 125-138

LOSSNAY SYSTEM

FEATURES & SPECIFICATIONS 139-150

P003-028.indd 4 13.12.12 1:17:04 PM


LINE-UP
M SERIES
INVERTER Models

1.5kW 1.8kW 2.0kW 2.2kW 2.5kW 3.5kW 4.2kW 5.0kW 6.0kW 7.1kW
Model Name Page
1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase

MSZ-F Series

SINGLE SINGLE SINGLE 31


H H H

MSZ-E Series S·B S·B


MXZ MXZ S·B S·B S·B S·B

connection connection SINGLE SINGLE SINGLE SINGLE 35


H H
only only

MSZ-S Series
MXZ MXZ
connection connection 37
only only
Wall-
mounted

SINGLE SINGLE SINGLE SINGLE 37

MSZ-G Series

SINGLE SINGLE 37

MSZ-H Series

SINGLE SINGLE SINGLE 41

MFZ Series
Compact 43
floor SINGLE SINGLE SINGLE

MLZ Series
1-way MXZ MXZ MXZ
cassette connection connection connection 45
only only only

H : Outdoor unit with freeze-prevention heater is available.


S·B: Indoor units are available in three colours; Silver, Black and White.

S SERIES
INVERTER Models

2.5kW 3.5kW 4.2kW 5.0kW 6.0kW 7.1kW 8.0kW 10.0kW 14.0kW 20.0kW
Model Name Page
1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 1-phase 1- & 3-phase 1- & 3-phase 1- & 3-phase

SLZ Series
L L L
2x2 SINGLE SINGLE SINGLE 51
cassette

SEZ Series
Compact L L L L L
ceiling- SINGLE SINGLE SINGLE SINGLE SINGLE 53
concealed

L : Indoor units are available in two types; with or without the wireless remote controller.

P003-028.indd 5 13.12.12 1:17:05 PM


Indoor Combinations
SINGLE 1 outdoor unit & 1 indoor unit
TWIN 1 outdoor unit & 2 indoor units
TRIPLE 1 outdoor unit & 3 indoor units
QUADRUPLE 1 outdoor unit & 4 indoor units

POWERFUL HEATING SERIES


INVERTER Models

2.5kW 3.5kW 5.0kW 7.1kW 10.0kW 12.5kW


Model Name Page
1-phase 1-phase 1-phase 1-phase 1- & 3-phase 3-phase

PLA Series
SINGLE SINGLE SINGLE
4-way cassette 83/87
TWIN TWIN TWIN

PKA Series
ZUBADAN SINGLE
Wall-mounted 83/89
TWIN

PEAD-JA Series
SINGLE SINGLE SINGLE
Ceiling-concealed 83/90
TWIN TWIN TWIN

MSZ-FH VEHZ Series

Wall-mounted SINGLE SINGLE SINGLE 85/91


H H H

MFZ-KJ VEHZ Series

Compact floor SINGLE SINGLE SINGLE 92


H H H

H: Freeze-prevention heater is included as standard equipment.

MXZ SERIES
INVERTER Models

Model Name Capacity Class Wall-mounted Floor-standing Cassette Ceiling-concealed Ceiling-suspended Page
up to 8 indoor units MSZ-FH25/35/50
MXZ-8B160VA 15.5kW MLZ-KA25/35/50
MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60/71
MXZ-8B160YA <1-phase> MFZ-KJ25/35/50 SLZ-KA25/35/50 95
MSZ-SF15/20/25/35/42/50 PEAD-RP50/60/71/100
<3-phase> PLA-RP35/50/60/71/100
MSZ-GF60/71

up to 8 indoor units MSZ-FH25/35/50


MXZ-8B140VA 14.0kW MLZ-KA25/35/50
MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60/71
MXZ-8B140YA <1-phase> MFZ-KJ25/35/50 SLZ-KA25/35/50 95
MSZ-SF15/20/25/35/42/50 PEAD-RP50/60/71/100
<3-phase> PLA-RP35/50/60/71/100
MSZ-GF60/71

up to 6 indoor units MSZ-FH25/35/50


MLZ-KA25/35/50
MXZ-6C122VA 12.2kW MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60/71
MFZ-KJ25/35/50 SLZ-KA25/35/50 PCA-RP50/60/71 95
<1-phase> MSZ-SF15/20/25/35/42/50 PEAD-RP50/60/71
PLA-RP50/60/71
MSZ-GF60/71
up to 5 indoor units MSZ-FH25/35/50
MLZ-KA25/35/50
MXZ-5D102VA 10.2kW MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60/71
MFZ-KJ25/35/50 SLZ-KA25/35/50 PCA-RP50/60/71 95
<1-phase> MSZ-SF15/20/25/35/42/50 PEAD-RP50/60/71
PLA-RP50/60/71
MSZ-GF60/71
up to 4 indoor units MSZ-FH25/35/50
MLZ-KA25/35/50
MXZ-4D83VA 8.3kW MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60/71
MFZ-KJ25/35/50 SLZ-KA25/35/50 PCA-RP50/60/71 95
<1-phase> MSZ-SF15/20/25/35/42/50 PEAD-RP50/60/71
PLA-RP50/60/71
MSZ-GF60/71
up to 4 indoor units MSZ-FH25/35/50
MLZ-KA25/35/50
MXZ-4D72VA 7.2kW MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60
MFZ-KJ25/35/50 SLZ-KA25/35/50 PCA-RP50/60 95
<1-phase> MSZ-SF15/20/25/35/42/50 PEAD-RP60
PLA-RP50/60
MSZ-GF60
up to 3 indoor units MSZ-FH25/35/50
MLZ-KA25/35/50
MXZ-3D68VA 6.8kW MSZ-EF18/22/25/35/42/50 SEZ-KD25/35/50/60
MFZ-KJ25/35/50 SLZ-KA25/35/50 PCA-RP50/60 95
<1-phase> MSZ-SF15/20/25/35/42/50 PEAD-RP60
PLA-RP50/60
MSZ-GF60
up to 3 indoor units MSZ-FH25/35/50 MLZ-KA25/35/50
MXZ-3D54VA2 5.4kW SEZ-KD25/35/50
MSZ-EF18/22/25/35/42/50 MFZ-KJ25/35/50 SLZ-KA25/35/50 PCA-RP50 95
<1-phase> PEAD-RP50
MSZ-SF15/20/25/35/42/50 PLA-RP50

up to 2 indoor units MSZ-FH25/35


5.3kW MLZ-KA25/35
MXZ-2D53VA (H) MSZ-EF18/22/25/35/42/50 MFZ-KJ25/35 SEZ-KD25/35 95
<1-phase> SLZ-KA25/35
MSZ-SF15/20/25/35/42/50

up to 2 indoor units MSZ-FH25/35


4.2kW MLZ-KA25/35
MXZ-2D42VA MSZ-EF18/22/25/35 MFZ-KJ25/35 SEZ-KD25/35 95
<1-phase> SLZ-KA25/35
MSZ-SF15/20/25/35

up to 2 indoor units MSZ-FH25


MXZ-2D33VA 3.3kW MLZ-KA25
MSZ-EF18/22/25 MFZ-KJ25 SEZ-KD25 95
<1-phase> SLZ-KA25
MSZ-SF15/20/25

✽ SEZ-KD25 is not applicable indoor unit to be connected with MXZ-2D/3D/4D/5D, when total capacity of connected indoor units is equivalent with outdoor capacity (capacity ratio is 1).
6

P003-028.indd 6 13.12.12 1:17:07 PM


LINE-UP
P SERIES
POWER INVERTER Models

3.5kW 5.0kW 6.0kW 7.1kW


Model Name
1-phase 1-phase 1-phase 1-phase

PLA Series
SINGLE
4-way cassette SINGLE SINGLE SINGLE
TWIN

PKA Series
SINGLE
Wall-mounted SINGLE SINGLE SINGLE
TWIN

PCA-KAQ Series
SINGLE
Ceiling-suspended SINGLE SINGLE SINGLE
TWIN

PCA-HAQ Series
Ceiling-suspended
SINGLE
for Professional Kitchen

PSA Series

Floor-standing SINGLE

PEAD-JA Series
SINGLE
SINGLE SINGLE SINGLE
TWIN
Ceiling-concealed
PEA Series

STANDARD INVERTER Models

3.5kW 5.0kW 6.0kW 7.1kW


Model Name
1-phase 1-phase 1-phase 1-phase

PLA Series
4-way cassette SINGLE SINGLE SINGLE SINGLE

PKA Series
Wall-mounted

PCA-KAQ Series
Ceiling-suspended SINGLE SINGLE SINGLE SINGLE

PCA-HAQ Series
Ceiling-suspended
for Professional Kitchen

PSA Series

Floor-standing

PEAD-JA Series
SINGLE SINGLE SINGLE SINGLE

Ceiling-concealed
PEA Series

P003-028.indd 7 13.12.12 1:17:10 PM


Indoor Combinations
SINGLE 1 outdoor unit & 1 indoor unit
TWIN 1 outdoor unit & 2 indoor units
TRIPLE 1 outdoor unit & 3 indoor units
QUADRUPLE 1 outdoor unit & 4 indoor units

10.0kW 12.5kW 14.0kW 20.0kW 25.0kW 40.0kW 50.0kW


Page
1- & 3-phase 1- & 3-phase 1- & 3-phase 3-phase 3-phase 3-phase 3-phase

SINGLE TWIN TWIN


SINGLE SINGLE
TWIN TRIPLE TRIPLE 59
TWIN TWIN TRIPLE QUADRUPLE QUADRUPLE

TWIN
SINGLE TWIN TRIPLE
TWIN TRIPLE 65
TWIN TRIPLE QUADRUPLE
QUADRUPLE

SINGLE TWIN TWIN


SINGLE SINGLE
TWIN TRIPLE TRIPLE 68
TWIN TWIN TRIPLE QUADRUPLE QUADRUPLE

TWIN TRIPLE 69

SINGLE TWIN
SINGLE SINGLE TWIN 73
TWIN TRIPLE

SINGLE TWIN TWIN


SINGLE SINGLE
TWIN TRIPLE TRIPLE 76
TWIN TWIN TRIPLE QUADRUPLE QUADRUPLE

✽ ✽
SINGLE SINGLE SINGLE SINGLE 79

✽ 1 indoor unit requires 2 outdoor units.

10.0kW 12.5kW 14.0kW 20.0kW 25.0kW 40.0kW 50.0kW


Page
1- & 3-phase 1- & 3-phase 1- & 3-phase 3-phase 3-phase 3-phase 3-phase

SINGLE TWIN TWIN


SINGLE SINGLE
TWIN TRIPLE TRIPLE 59
TWIN TWIN
TRIPLE QUADRUPLE QUADRUPLE

TWIN
SINGLE TWIN TRIPLE
TWIN TRIPLE 65
TWIN TRIPLE QUADRUPLE
QUADRUPLE

SINGLE TWIN TWIN


SINGLE SINGLE
TWIN TRIPLE TRIPLE 68
TWIN TWIN QUADRUPLE
TRIPLE QUADRUPLE

TWIN TRIPLE 69

SINGLE TWIN
SINGLE SINGLE TWIN 73
TWIN TRIPLE

SINGLE TWIN TWIN


SINGLE SINGLE
TWIN TRIPLE TRIPLE 76
TWIN TWIN
TRIPLE QUADRUPLE QUADRUPLE

✽ ✽
SINGLE SINGLE SINGLE SINGLE 79

✽ 1 indoor unit requires 2 outdoor units.


8

P003-028.indd 8 13.12.12 1:17:13 PM


NEW ECODESIGN DIRECTIVE

WHAT IS THE ErP DIRECTIVE?


The Ecodesign Directive for Energy-related Products (ErP Directive) establishes a framework to set mandatory standards for ErPs sold in the
European Union (EU). The ErP directive introduces new energy-efficiency ratings across various product categories and affects how products such
as computers, vacuum cleaners, boilers and even windows are classified in terms of environmental performance.
Regulations that apply to air conditioning systems of rated capacity up to 12kW came into effect as of January 1, 2013. Based the use of future-
orientated technologies, Mitsubishi Electric is one step ahead of these changes, with our air conditioning systems already achieving compliance
with these new regulations.

NEW ENERGY LABEL AND MEASUREMENTS


Under regulation 2011/626/EU, supplementing directive 2010/30/EU, air conditioning systems are newly classified into energy-efficiency classes
on the basis of a new energy labelling system, which includes three new classes: A+, A++ and A+++.
Revisions to the measurement points and calculations of the seasonal energy efficiency ratio (SEER) and seasonal coefficient of performance
(SCOP) has resulted in changes to how air conditioning systems are classified into energy-efficiency classes.
Specifically, for cooling mode, air conditioning systems must be at least class D by January 1, 2013, and at least class B one year later. For heating
mode, air conditioning systems must be at least class A by January 1, 2013 and at least class A+ one year later.

■New Energy Efficiency Label ■Climate Zones for Heating Mode


SEER and SCOP Name or trademark of the manufacturer Reference climate zones for calculating the SCOP
The SEER (Seasonal Energy Efficiency Ratio) Since the climate conditions have a great influence on the operating
Name of the unit/designation of model
value indicates the seasonal energy efficiency behaviour in the heat pump mode, three climate zones have
value in the cooling mode. The SCOP (Seasonal been stipulated for the EU: warm, moderate, cold. The measurement
Coefficient of Performance) value refers to the points are homogenous at 12°C, 7°C, 2°C and –7°C.
seasonal efficiency in the heating mode.

Energy efficiency classes from A+++ to D Helsinki


SCOP in heating mode
A +++ > 5,1
A ++ > 4,6 Strasbourg
Strasbourg also
A+ > 4,0 serves as basis for
A > 3,4 I II calculating the SEER.
B > 3,1
C > 2,8
D < 2,5

Energy efficiency classes from A+++ to D


SEER in cooling mode
A +++ > 8,5
A ++ > 6,1
A+ > 5,6
A > 5,1
B > 4,6
C > 4,1
D < 3,6

Energy efficiency class


Energy efficiency class of the Athens
unit in cooling and heating
mode of the unit model
In the heating mode, the indication XY,Z XY,Z XY,Z XY,Z Warm (Athens)
for the unit model is shown for
all three climate zones. X,Y X,Y X,Y X,Y Temperature conditions
XY XY XY XY Partial Outdoors Indoors
Nominal capacity in cooling mode
load DB WB DB
SEER value
Annual power consumption for cooling – – – 20°C
100% 2°C 1°C 20°C
Operating noise, indoors/outdoors
ZY 64% 7°C 6°C 20°C
The sound power level is an 29% 12°C 11°C 20°C
important sound energy parameter
for assessing a sound source.
Moderate (Strasbourg)
Contrary to the sound pressure -
the sound power is independent Temperature conditions
of the location of the source Outdoors Indoors
and/or the receiver. ZY Partial
load DB WB DB
Maximally admissible values are:
88% –7°C –8°C 20°C
54% 2°C 1°C 20°C
Cooling capacity Cooling capacity 35% 7°C 6°C 20°C
≤ 6 kW > 6 kW ≤ 12 kW XYZ/2012 15% 12°C 11°C 20°C
Indoor unit Outdoor unit Indoor unit Outdoor unit
Cold (Helsinki)
60dB(A) 65dB(A) 60dB(A) 70dB(A) Time reference Nominal capacity in heating mode Temperature conditions
Indication on label data SCOP value
Partial Outdoors Indoors
Annual power consumption for heating load DB WB DB
Climate zones 61% –7°C –8°C 20°C
For heating mode, the EU is divided into three climate zones for
calculation and classification purposes. This aims at calculating
37% 2°C 1°C 20°C
the energy efficiency taking into consideration the actual regional 24% 7°C 6°C 20°C
ambient temperatures. 11% 12°C 11°C 20°C

P003-028.indd 9 13.12.12 1:17:15 PM


SEER/SCOP
Air conditioning systems were previously assessed using the energy-efficiency rating (EER), which evaluated efficiency in cooling mode, and the
coefficient of performance (COP), which defined the efficiency, or the ratio of consumed and output power, in heating mode. Under this system,
assessments were not truly reflective of performance as they were based on a single measurement point, which led to manufacturers optimising
products accordingly in order to achieve higher efficiency ratings. SEER and SCOP address this problem by including seasonal variation in the
ratings via use of realistic measurement points. For cooling mode, measurements at outside temperatures of 20, 25, 30 and 35°C are incorporated
and weighted in accordance with climate data for Strasbourg, which is used as a single reference point for the whole EU. For instance, for
partial-load operation, which represents more than 90% of operation, there is a correspondingly high weighting for the efficiency classification. For
heating mode, a comprehensive temperature profile for the whole EU was not possible, so the EU has been divided into three climate zones,
north, central and south, and load profiles created. The same measurement points, at outside temperatures of 12, 7, 2 and –7°C, are used for all
three zones.

■SCOP Calculation
Technical Terms with Respect to the SCOP
P design H
P design H: Corresponds to a heating load of 100%.
T bivalent Heating capacity at The value depends on the selected bivalence point.
nominal frequency
T design: Outside temperature which determines
the P design H point. The latter is determined from
the area conditions.
SCOP calculation in
the heat pump mode T bivalent: Corresponds to the lowest temperature
If T bivalent is high at which full heating performance can be achieved
P design H = high with the heat pump (without additional heating).
SCOP = low
This point can be freely selected within the pre-
scribed temperature ranges (T design - T bivalent).
Outside
-10°C -7°C -2°C 16°C temperature

SOUND PRESSURE LEVEL


Consumers will also receive more information on the noise ■ Sound Pressure vs Sound Power Level
levels emitted by split-system air conditioners to help them
make their purchasing decision. Specifically, the sound power
level of indoor and outdoor units is to be indicated in decibels
as an objective parameter. Knowing the sound power makes
it possible to calculate sound emissions while considering
distance and radiation characteristics, which is beneficial
because it allows the noise levels of different air conditioning
systems to be compared regardless of the usage location and
how the sound pressure is measured. This is an improvement
on sound pressure values which are usually measured at an
approximate distance of 1m where all modern split-system air
conditioning systems tend to be very quiet at an average of
21 decibels.

Sound pressure level dB(A) Sound power level dB(A)


The sound pressure level is a sound field parameter The sound power is an acoustic parameter which
which indicates the perceived operating noise of an describes the source strength of a sound generator
indoor unit within a certain distance. and is thus independent of the distance to the
receiver location.

10

P003-028.indd 10 13.12.12 1:17:16 PM


INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result,
optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and amazingly low running cost — That’s the Mitsubishi Electric promise.

INVERTERS – HOW THEY WORK


Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner.
They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly
regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and
providing the most comfortable room environment.

ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter air conditioners. We’ve combined advanced inverter technologies with cutting-edge
electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency.
Better performance and lower energy consumption are the result.

TRUE COMFORT
Simple comparison of air conditioner operation control with and without inverter.

■ Inverter Operation Image (cooling mode)


Temperature (°C) Cooling capacity (W)

Point 1
When room temperature is higher than the
setting, capacity rises for the quickly adjust-
Rated capacity
ing the temperature to the original setting.

Setting temperature
Indoor temperature
Point 2
When room temperature reaches the desired
Measured capacity
setting, capacity eases in order to maintain
the set temperature level.

Operation time (min)

Point 1 Quick & Powerful Point 2 Room Temperature Maintained


Increasing the compressor motor speed by controlling the operation The compressor motor operating frequency and the change of room
frequency ensures powerful output at start-up, brings the room temperature are monitored to calculate the most efficient waveform
temperature to the comfort zone faster than units not equipped with to maintain the room temperature in the comfort zone. This elimi-
an inverter. Hot rooms are cooled, and cold rooms are heated faster nates the large temperature swings common with non-inverter sys-
and more efficiently. tems, and guarantees a pleasant, comfortable environment.

KEY TECHNOLOGIES
Our Rotary Compressor Our Scroll Compressor
Our rotary compressors use our original “Poki-Poki Motor” and Our scroll compressors are equipped with an advanced frame
“Heat Caulking Fixing Method” to realise downsizing and higher compliance mechanism that allows self-adjustment of the position
efficiency, and are designed to match various usage scenes in of the orbiting scroll according to pressure load and the accuracy of
residential to commercial applications. Additionally, development of the fixed scroll position. This minimises gas leakage in the scroll
an innovative production method known as “Divisible Middle Plate” compression chamber, maintains cooling capacity and reduces
realises further size/weight reductions and increased capacity while power loss.
also answering energy-efficiency needs.

11

P003-028.indd 11 13.12.12 1:17:16 PM


MORE ADVANTAGES WITH MITSUBISHI ELECTRIC
Joint Lap DC Motor Vector-Wave Eco Inverter
Mitsubishi Electric has developed a unique motor, This inverter monitors the varying compressor motor frequency and
called the “Poki-Poki Motor” in Japan, which is creates the most efficient waveform for the motor speed. As the
manufactured using a joint lapping technique. result, operating efficiency in all speed ranges is improved, less
This innovative motor operates based on a high- power is used and annual electricity cost is reduced.
density, high-magnetic force, leading to extremely Smooth wave pattern
Sine-wave drive soft PWM
high efficiency and reliability.
Inverter size has been reduced using insert-
molding, where the circuit pattern is molded into
the synthetic resin. To ensure quiet operation,
soft PWM control is used to prevent the metallic
Magnetic Flux Vector Sine Wave Drive whine associated with conventional inverters.

This drive device is actually a microprocessor that converts the com-


pressor motor’s electrical current waveform from a conventional wave-
form to a sine wave (180°conductance) to achieve higher efficiency by
raising the motor winding utilisation ratio and reducing energy loss. PAM (Pulse Amplitude Modulation)
PAM is a technology that controls the current waveform so that it
resembles the supply voltage wave, thereby reducing loss and real-
Reluctance DC Rotary Compressor ising more efficient use of electricity. Using PAM control, 98% of the
input power supply is used effectively.
Powerful neodymium magnets are used in the rotor of the reluc-
tance DC motor. More efficient operation is realised by strong mag-
netic and reluctance torques produced by the magnets. Without PAM control With PAM control
Supply
voltage

Time
DC compressor Neodymium Current Time
motor ( rotor ) magnets

PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.

Magnetic torque
+ ■ Merits of PAM Control Power increased
Reluctance torque Efficient voltage increase
realises increased power
Significant energy savings PAM
Remarkable reduction in power
loss saves electricity
Highly Efficient DC Scroll Compressor Conventional
inverter

Higher efficiency has been achieved by adding a


Limited power
frame compliance mechanism to the DC scroll Limited energy savings Insufficient power
compressor. The mechanism allows movement Electricity is wasted when needed
in the axial direction of the frame supporting the
cradle scroll, thereby greatly reducing leakage
and friction loss, and ensuring extremely high
efficiency at all speeds. Power Receiver and Twin LEV Control
Mitsubishi Electric has developed a power receiver and twin linear
Fixed scroll expansion valves (LEVs) circuit that optimise compressor perfor-
Leakage loss (minimum)
mance. This technology ensures optimum control in response to op-
Frame can
Thrust gas power (minimum)
move in direction erating waveform and outdoor temperature. Operating efficiency has
of axis
Thrust friction loss (minimum) been enhanced by tailoring the system to the characteristics of R410A
refrigerant.
Secondary back-pressure chamber
minimises thrust friction loss
Substantial
reduction in leakage
and friction loss Primary back-chamber minimises
leakage loss
Heat Compressor
Frame Cradle scroll
exchanger

Heat Caulking Power Heat


Fixing Method Heat Caulking Fixing Method receiver exchanger

To fix internal parts in place, a “Heat Caulking LEV1 LEV2


Fixing Method” is used, replacing the former arc
spot welding method. Distortion of internal parts
is reduced, realising higher efficiency.

Grooved Piping Grooved piping

DC Fan Motor High-performance grooved piping


is used in heat exchangers to in-
A highly efficient DC motor drives the fan of the outdoor unit. crease the heat exchange area. Pipe image
Efficiency is much higher than an equivalent AC motor. Cross-sectional view

12

P003-028.indd 12 13.12.12 1:17:18 PM


FUNCTIONS (1 )

ENERGY-SAVING
Indirect Airflow Direct Airflow
The indirect airflow setting can be used This setting can be used to directly target
The FH Series is equipped with 3D i-see Sensor, an infrared-ray when the flow of air feels too strong or airflow at people such as for immediate
direct. For example, it can be used during comfort when coming indoors on a hot
sensor that measures the temperature at distant positions. While cooling to avert airflow and prevent body (cold) day.
moving to the left and right, eight vertically arranged sensor temperature from becoming excessively
elements analyze the room temperature in three dimensions. This cooled.
detailed analysis makes it possible to judge where people are
in the room, thus allowing creation of features such as “Indirect
airflow,” to avoid airflow hitting people directly, and “direct airflow”
to deliver airflow to where people are.

Sensor with
eight elements
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode.

8 × 94 areas

Sensor measures while


moving to the left to right

Divided into 94
(Image) The “3D i-see Sensor” detects people’s absence and the power consumption is automatically
reduced approximately 10% after 10 minutes and 20% after 60 minutes.

Area Temperature Monitor


Cooling mode
The “i-see Sensor” monitors the whole room in sections and directs the
Warmer Cooler
airflow to areas of the room where the temperature does not match the Daytime
area
Nighttime area
temperature setting. (When cooling the room, if the middle of the room is
detected to be hotter, more airflow is directed towards it.) This eliminates
unnecessary heating /cooling and contributes to lower electricity costs.

Econo Cool Energy-Saving Feature Demand Function (Onsite Adjustment)


“Econo Cool” is an intelligent temperature control feature that adjusts The demand function can be activated when the unit is equipped
the amount of air directed towards the body based on the air-outlet with a commercially available timer or an On/Off switch is added to
temperature. The setting temperature can be raised by as much as the CNDM connector (option) on the control board of the outdoor
2°C without any loss in comfort, thereby realising a 20% gain in unit. Energy consumption can be reduced up to 100% of the normal
energy efficiency. (Function only available during manual cooling operation.) consumption according to the signal input from outside.
Conventional Econo Cool [Example: Power Inverter Series]
Ambient temperature 35°C 35°C Limit energy consumption by changing the settings of SW7-1, SW2
Set temperature 25°C 27°C and SW3 on the control board of the outdoor unit. The following
Perceived temperature 30°C 29.3°C settings are possible.

Econo Cool Mode SW7-1 SW2 SW3 Energy consumption


A comfortable room environment is maintained even when setting the
OFF OFF 100%
temperature 2°C higher than the conventional cooling mode.
ON OFF 75%
Econo Cool on Conventional cooling mode
ON
ON ON 50%

OFF ON 0% (Stop)
✽PUHZ outdoor only

Temperature distribution (°C)

14 16 18 20 22 24 26 28

13

P003-028.indd 13 13.12.12 1:17:19 PM


ATTRACTIVE
Pure White Auto Vane
Pure white is adopted for the unit colour; white expressing the The vane closes automatically when the air conditioner is not
essence of cleanliness and easily matching virtually all interior décor. running, concealing the air outlet and creating a flat surface that is
aesthetically appealing.

AIR QUALITY
Plasma Quad Catechin Filter
Plasma Quad attacks bacteria and viruses from inside the unit using Catechin is a bioflavonoid by-product of green tea with both antiviral
a strong curtain-like electrical field and discharge of electric current and antioxidant qualities. It also has an excellent deodourising effect,
across the whole inlet-air opening of the unit. which is why Mitsubishi Electric uses the compound in its air condi-
tioner filters. In addition to improving air quality, it prevents the
Air Cleaning Filter spreading of bacteria and viruses throughout the room. Easily re-
moved for cleaning and maintenance, when the filter is washed regu-
The filter is charged with static electricity, enabling it to attract and larly the deodourising action is rated to last more than 10 years.
capture dust particulates that regular filters don’t.

Fresh-air Intake Oil Mist Filter


Indoor air quality is enhanced by the direct intake of fresh exterior air. The oil mist filter prevents oil mist from penetrating into the inner part
of the air conditioner.
Anti-allergy Enzyme Filter
Long-life Filter
The anti-allergy enzyme filter works to trap allergens such as molds
and bacteria and decompose them using enzymes retained in the A special process for the entrapment surface improves the filtering
filter. effect, making the maintenance cycle longer than that of units
equipped with conventional filters.
High-efficiency Filter
This high-performance filter has a much finer mesh compared to stan- Filter Check Signal
dard filters, and is capable of capturing minute particulates floating in
Air conditioner operating time is monitored, and the user is notified
the air that were not previously caught.
when filter maintenance is necessary.
Nano
Platinum Nano Platinum Filter
Electrostatic
Anti-allergy Electrostatic Anti-allergy Enzyme Filter
The filter has a large capture area and incorporates nanometre-sized
platinum-ceramic particles that work to kill bacteria and deodourise This function features both the Air Cleaning Filter and Anti-allergy
the circulating air. Enzyme Filter.

AIR DISTRIBUTION
Double
Vane Double Vane High Ceiling Mode
Double vane separates the airflow in the different directions to In the case of rooms with high ceilings, the outlet-air volume can be
deliver airflow not only across a wide area of the room, but also increased to ensure that air is circulated all the way to the floor.
simultaneously to two people in different locations.

Horizontal Vane Low Ceiling Mode


The air outlet vane swings up and down so that the airflow is spread If the room has a low ceiling, the airflow volume can be reduced for
evenly throughout the room. less draft.

Vertical Vane Auto Fan Speed Mode


The air outlet fin swings from side to side so that the airflow reaches The airflow speed mode adjusts the fan speed of the indoor unit
every part of the room. automatically according to the present room conditions.

14

P003-028.indd 14 13.12.12 1:17:20 PM


FUNCTIONS (2)

CONVENIENCE
On/Off Operation Timer
Use the remote controller to set the times of turning the air conditioner On/Off.

“i save” Mode
“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing
a single button on the remote controller. Press the same button twice in repetition to immediately
return to the previous temperature setting.
Using this function contributes to comfortable waste-free operation, realising the most suitable air
conditioning settings and saving on power consumption when, for example, leaving the room or
going to bed.

Heating Heating

i save

✽ Temperature can be preset to 10°C when heating in the “i-save” mode. Photo of MFZ Series remote controller

Auto Changeover Auto Restart


The air conditioner automatically switches between heating and cool- Especially useful at the time of power outages, the unit turns back on
ing modes to maintain the desired temperature. automatically when power is restored.

Low-temperature Cooling Low-noise Operation (Outdoor Unit)


Intelligent fan speed control in the outdoor unit ensures optimum System operation can be adjusted to prioritise less noise from the
performance even when the outside temperature is low. outdoor unit over air conditioning performance.

Ampere Limit Adjustment ■ Dip Switch Setting (Board for MXZ-5D102)

Dip switch settings can be used to adjust the maximum electrical


current for operation. This function is highly recommended for SW2 Ampere Limit
managing energy costs. 10.5A

*Maximum capacity is lowered with the use of this function. 15.5A


Full
(default setting)
✽ MXZ-5D102

Operation Lock ■ Dip Switch Setting (Board for MXZ-5D102)

To accommodate specific use applications, cooling or heating


operation can be specified when setting the control board of the
outdoor unit. A convenient option when a system needs to be
configured for exclusive cooling or heating service.

COOL/DRY HEAT

15

P003-028.indd 15 13.12.12 1:17:20 PM


Built-in Weekly Timer Function
Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

■ Example Operation Pattern (Winter/Heating mode)


Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C
Automatically changes to high-power operation at wake-up time

OFF OFF OFF OFF OFF ON 18°C ON 18°C


Midday is warmer,
Automatically turned off during work hours so the temperature is set lower

ON 22°C ON 22°C ON 22°C ON 22°C ON 22°C ON 22°C ON 22°C


Automatically raises temperature setting to
Automatically turns on, synchronized with arrival at home match time when outside-air temperature is low
(during sleeping hours)
ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C
Automatically lowers temperature at bedtime for energy-saving operation at night

Pattern Settings: Input up to four settings for each day


Settings
Settings: • Start/Stop operation • Temperature setting ✽ The operation mode cannot be set.

■ Easy set-up using dedicated buttons


PUSH PUSH PUSH
The remote controller is How to set
equipped with buttons that the Weekly
are used exclusively for Timer Select the day Select the period
setting the Weekly Timer. Ready to set
Setting operation patterns
is easy and quick.
PUSH
PUSH PUSH PUSH

Complete Select ON/OFF Select the time Set the temperature

• Start by pushing the “SET” button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the
indoor unit and push the “SET” button one more time. (Push the “SET” button only after in-
putting all of the desired patterns into the remote controller memory. Pushing the “CANCEL”
button will end the set-up process without sending the operation patterns to the indoor unit).
• It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.

SYSTEM CONTROL
PAR-31MAA /PAC-YT52CRA COMPO (Simultaneous Multi-unit Operation)
Units are compatible for use with the PAR-31MAA or PAC-YT52CRA Multiple indoor units can be connected to a single outdoor unit.
remote controller, which has a variety of management functions. (Depending on the unit combination, connection of up to four units is
possible; however, all indoor units must operate at the same settings.)

System Group Control MXZ Connection


The same remote controller is capable of controlling the operational Connection to the MXZ multi-split outdoor unit is possible.
status of up to 16 refrigerant systems.

Wi-Fi
M-NET Connection Interface Wi-Fi Interface
Units can be connected to MELANS system controllers (M-NET Interface enabling users to control air conditioners and check operat-
controllers) such as the AG-150A. ing status via devices such as personal computers, tablets and smart-
phones.

16

P003-028.indd 16 13.12.12 1:17:20 PM


FUNCTIONS (3)

INSTALLATION
Cleaning-free Pipe Reuse
It is possible to reuse the same piping. It allows cleaning-free renewal of air conditioning systems that use R22 or R410 refrigerant.

Reuse of Existing Wiring


Wiring recycling problem solved! Compatible with other wiring connection methods*
The wiring method has been improved, making it possible to use methods different from that utilized for control and power supply. Units are
compatible with the dual harness control line/power line method and the separate power supply method. Using a power supply terminal kit, wire
can be efficiently reused at the time of system renewal regardless of the method the existing system uses.
* Optional. Usage may be limited due to wiring type diameter.

Single Harness Control/Power Line Method Dual Harness Control Line/Power Line Method Separate Power Supply Method
(Current method)

Indoor unit (factory-shipped condition) Indoor unit (factory-shipped condition) Power supply

Control board Control board Control board


Indoor unit Indoor unit Indoor unit
Indoor/Outdoor unit Indoor/Outdoor unit Indoor/Outdoor unit
Power communication Power communication Power communication
Junction connectors Junction connectors
replaced replaced
Control
Junction 2 cores
Control/ connector S1 S2 S3 Power S1 S2 S3 Control S1 S2 S3
Power Outdoor unit Control/ 2 cores Outdoor unit 2 cores Outdoor unit
3 cores Power L N (polarised) L N
3 cores Power Control Control
2 cores 2 cores to power 2 cores
Power supply Power supply Power supply
L N S1 S2 S3 L N S1 S2 S3 L N S1 S2 S3

to power Power supply terminal kit (optional) to power Power supply terminal kit (optional) to power

Wiring/Piping Correction Function*


The push of a single button is all that is required to confirm that Wiring
confirmation The outdoor unit
piping and wiring are properly connected. Corrections are made au- is time matches
tomatically if a wiring error is detected, eliminating the need for com- consuming. pipes and wiring.

plicated wiring confirmation work when expanding the number of


rooms served.
* This function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10–20 minutes, and only works when the unit is set
to the Cooling mode.

Drain Pump Pump Down Switch


A built-in drain pump enables drain piping to be raised. Enables smooth and easy recovery of refrigerant. Simply press the
“Pump Down” switch before moving or changing the unit.
Outdoor unit control circuit board
Built-in drain pump efficiently
pumps out water
Pump Down Switch

Push this switch to start/


stop refrigerant recovery
operation automatically.
Photo of Model PUHZ-P100 (Valve in refrigerant circuit
is opened/closed.)
Flare Connection Pump down switch

Flare connection to cooling pipe work is possible.

17

P003-028.indd 17 13.12.12 1:17:21 PM


MAINTENANCE
Quick Clean Body
Exclusive Quick Clean Kit (Optional)
Our exclusive “Quick Clean Kit” can be easily connected to a household vacuum cleaner for quick and easy cleaning of the heat exchanger.*
*Wearing gloves is highly recommended when cleaning the heat exchanger, because touching it with bare hands can cause injury.

Self-Diagnostic Function (Check Code Display)


Check codes are displayed on the remote controller or the operation indicator to inform the user of malfunctions detected.

Failure Recall Function


Operation failures are recorded, allowing confirmation when needed.

18

P003-028.indd 18 13.12.12 1:17:21 PM


FUNCTION LIST (1 )
Category Icon Combination M SERIES

Indoor unit MSZ-FH25/35/50VE MSZ-EF18/22/25/35/42/50VE(W)(B)(S) MSZ-SF15/20VA MSZ-SF25/35/42/50VE

MUZ MXZ MXZ MXZ MXZ MXZ MXZ MUZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MUZ MXZ MXZ MXZ MXZ MXZ MXZ
Outdoor unit
-FH -2D -3D -4D -5D -6C -8B -EF -2D -3D -4D -5D -6C -8B -2D -3D -4D -5D -6C -8B -SF -2D -3D -4D -5D -6C -8B

Technology DC Inverter

Joint Lap DC Motor 72 72 72 72


Magnetic Flux Vector Sine Wave Drive

Reluctance DC Rotary Compressor 83 83 83 83


Highly Efficient DC Scroll Compressor

Heating Caulking (Compressor) 72 72 72 72


DC Fan Motor

Vector-Wave Eco Inverter

PAM (Pulse Amplitude Modulation)

Power Receiver and Twin LEV Control

Grooved Piping
Energy Felt Temperature Control (3D i-see Sensor)
Saving
AREA Temperature Monitor

Econo Cool Energy-saving Feature

Standby Power Consumption Cut

Demand Function Opt Opt Opt Opt

Attractive Pure White VEW VEW VEW VEW VEW VEW VEW
Auto Vane
Air Quality Plasma Quad

Fresh-air Intake

Anti-allergy Enzyme Filter

Electrostatic Anti-allergy Enzyme Filter Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

High-efficiency Filter

Catechin Filter

Nano Platinum Filter

Oil Mist Filter

Long-life Filter

Filter Check Signal


Air Double Vane
Distribution
Horizontal Vane

Vertical Vane

High Ceiling Mode

Low Ceiling Mode

Auto Fan Speed Mode \


Functions

Convenience On/off Operation Timer \


"i save" Mode

Auto Changeover *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1
Auto Restart

Low-temperature Cooling

Low-noise Operation (Outdoor Unit)

Ampere Limit Adjustment 83 83 83 83


Operation Lock

Built-in Weekly Timer Function

Rotation, Back-up and 2nd Stage Cut-in Functions


System PAR-31MAA Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
Control
PAC-YT52CRA Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Centraliesd On/Off Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

System Group Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

M-NET Connection *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

COMPO *4

MXZ Connection *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2
Installation Cleaning-free Pipe Reuse

Reuse of Existing Wiring

Wiring/Piping Correction Function

Drain Pump

Pump Down Switch

Flare Connection
Maintenance Self-Diagnosis Function (Check Code Display)

Failure Recall Function

*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible. *3 Please refer to "System Control" on pages 25-26 for details.
*2 For the possible connectivity of MXZ outdoor units and indoor units, please refer to the list on page 99 for details. *4 Please refer to page 54 for details.

19

P003-028.indd 19 13.12.12 1:17:22 PM


M SERIES S SERIES
MSZ-
MSZ-GF60/71VE HJ25/35 MFZ-KJ25/35/50VE MLZ-KA25/35/50VA SLZ-KA25/35/50VAL/VAQ SEZ-KD25/35/50/60/71VAL/VAQ
/50VA

MUZ MXZ MXZ MXZ MXZ MXZ MUZ MUFZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ SUZ MXZ MXZ MXZ MXZ MXZ MXZ SUZ MXZ MXZ MXZ MXZ MXZ MXZ
-GF -3D -4D -5D -6C -8B -HJ -KJ -2D -3D -4D -5D -6C -8B -2D -3D -4D -5D -6C -8B -KA -2D -3D -4D -5D -6C -8B -KA -2D -3D -4D -5D -6C -8B

72 72 72 72 72

83 83 83 83 83

72 35 72 72 72 72

50

Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt

VAQ VAQ VAQ VAQ VAQ VAQ VAQ

*1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1

83 83 83 83 83

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

*2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 *2

Opt Opt Opt Opt Opt Opt Opt

• The figures listed in the table are "only when combined with an outdoor unit with the appropriate capacity range".
• Opt: Separate parts must be purchased.

20

P003-028.indd 20 13.12.12 1:17:22 PM


FUNCTION LIST (2)
Category Icon Combination P SERIES

Indoor unit PLA-(Z)RP35/50/60/71/100/125/140BA PEAD-RP35/50/60/71/100/125/140JA(L)Q

PUHZ PUHZ PUHZ SUZ MXZ MXZ MXZ MXZ MXZ PUHZ PUHZ PUHZ SUZ MXZ MXZ MXZ MXZ MXZ
Outdoor unit
-SHW -(Z)RP -P -KA -3D -4D -5D -6C -8B -SHW -(Z)RP -P -KA -3D -4D -5D -6C -8B

Technology DC Inverter

Joint Lap DC Motor 35-71 35-71


Magnetic Flux Vector Sine Wave Drive

Reluctance DC Rotary Compressor 100-140 83 100-140 83


Highly Efficient DC Scroll Compressor 100-250 200/250 100-250 200/250
Heating Caulking (Compressor) 35-71 72 35-71 72
DC Fan Motor

Vector-Wave Eco Inverter

PAM(Pulse Amplitude Modulation) 35-140 100-140 35-140 100-140


Power Receiver and Twin LEV Control

Grooved Piping

Energy Felt Temperature Control (i-see Sensor)


Saving
AREA Temperature Monitor Opt Opt Opt Opt Opt Opt Opt Opt Opt

Econo Cool Energy-saving Feature

'I-Feel' Control

Demand Function Opt Opt Opt Opt Opt Opt Opt Opt

Attractive Pure White

Auto Vane

Air Quality Plasma Quad

Fresh-air Intake

Anti-allergy Enzyme Filter

High-efficiency Filter Opt Opt Opt Opt Opt Opt Opt Opt Opt

Catechin Filter

Oil Mist Filter

Long-life Filter

Filter Check Signal

Air Horizontal Vane


Distribution
Vertical Vane

High Ceiling Mode

Low Ceiling Mode

Auto Fan Speed Mode \


Convenience On/off Operation Timer

"i save" Mode


Functions

Auto Changeover *1 *1 *1 *1 *1
Auto Restart

Low-temperature Cooling

Low-noise Operation (Outdoor Unit)

Ampere Limit Adjustment 60-140V 60-140V


112/140 200/250 83 112/140 200/250 83

Operation Lock

Built-in Weekly Timer Function

Rotation, Back-up and 2nd Stage Cut-in Functions Opt Opt Opt Opt Opt Opt

System PAR-31MAA Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
Control
PAC-YT52CRA Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Centraliesd On/Off Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

System Group Control *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

M-NET Connection *3 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

COMPO *4 71-250 71-250


MXZ Connection *2 *2 *2 *2 *2 *2 *2 *2 *2 *2
Installation Cleaning-free Pipe Reuse

Reuse of Existing Wiring Opt Opt Opt Opt Opt Opt

Wiring/Piping Correction Function

Drain Pump *5 *5 *5 *5 *5 *5 *5 *5 *5
Pump Down Switch

Flare Connection

Maintenance Quick Clean Body

Self-Diagnosis Function (Check Code Display)

Failure Recall Function

*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible. *4 Please refer to page 16 for details.
*2 For the possible connectivity of MXZ outdoor units and indoor units, please refer to the list on page 95 for details. *5 PEAD-RP JALQ are not equipped with a drain pump.
*3 Please refer to "System Control" on pages 27-28 for details.

21

P003-028.indd 21 13.12.12 1:17:22 PM


P SERIES
PEA-
PKA- PSA-RP71/
RP200/250 PKA-RP60/71/100KAL PCA-RP35/50/60/71/100/125/140KAQ PCA-RP71HAQ
RP35/50HAL 100/125/140KA
/400/500GAQ

PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ PUHZ SUZ MXZ MXZ MXZ MXZ PUHZ PUHZ PUHZ PUHZ
-RP -P -(Z)RP -P -SHW -(Z)RP -P -(Z)RP -P -KA -3D -4D -5D -6C -(Z)RP -P -(Z)RP -P

35-71 60-71 50-71 71 71

100-140 100-140 100-140 83 100/125 100-140

100-200 200 100-250 200/250 100-250 200/250 100-250 250 100-250 200/250

35-71 35-71 35-71 72 35-71 35-71

35-140 100-140 60-140 100-140 50-140 100-140 71-140 125/140 71-140 100-140

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt

*1 *1 *1 *1

60-140V 60-140V 60-140V 71-140V 71-140V


200/250 112/140 200/250 200/250 83 200/250 200/250

Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

71-250 71-250 71-250 71-250 71-250

*2 *2 *2 *2

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

• If a numerical figure is listed, the feature is only available with the outdoor unit of that capacity.
• Opt: Optional parts must be purchased.

22

P003-028.indd 22 13.12.12 1:17:22 PM


CONTROL TECHNOLOGIES

User-friendly Deluxe Remote Controller with Excellent


Operability and Visibility
PAR-31MAA

Easy To Read & Easy To Use


Full Dot Liquid-crystal Display Adopted
Easier to read thanks to use of a full dot liquid-crystal display Display Example [Operation Mode]
with backlight, and easier to use owing to adopting a menu
Full Dot LCD
format that has reduced the number of operating buttons.

Multi-language Display
Control panel operation in eight [English] [Spanish] [Italian] [German]
Multi- different languages
Ianguage Choose the desired language, among the
following languages.

[French] [Russian] [Portuguese] [Swedish]

Energy-efficient Control
Operation Control Functions

Energy- Prevents wasteful operation by automati-


Saving Precise control of power consumption Auto-return cally returning to the preset temperature
Schedule after specified operating time

The amount of power consumed in each time period is managed so After adjusting the temperature for initial heating in winter or cool-
that the demand value is not exceeded. The demand control func- ing on a hot summer day, it is easy to forget to return the tempera-
tion can be set to start and finish in 5-minute units. Additionally, the ture setting to its original value. The Auto-return function automati-
level can be adjusted to 0, 50, 60, 70, 80 or 90% of maximum capac- cally resets the temperature back to the original setting after a spec-
ity, and up to 4 patterns can be set per day. Air-conditioning opera- ified period of time, thereby preventing overheating/overcooling.
tion is automatically controlled to ensure that electricity in excess of The Auto-return activation time can be set in 10-minute units, in a
the contracted volume is not consumed. range between 30 and 120 minutes.
*Auto-return cannot be used when Temperature Range Restrictions is in use.
■ Setting pattern example
Start time Finish time Capacity savings

8:15 12:00 80%

12:00 13:00 50%

13:00 17:00 90%

17:00 21:00 50%

23

P003-028.indd 23 13.12.12 1:17:22 PM


Night Keep desired room temperatures Auto-off Turns heating/cooling off automatically
Setback automatically Timer after preset time elapses

This function monitors the room temperature and automatically acti- When using Auto-off Timer, even if one forgets to turn off the unit,
vates the heating mode when the temperature drops below the operation stops automatically after the preset time elapses, thereby
preset minimal temperature setting. It has the same function for preventing wasteful operation. Auto-off Timer can be set in 10-
cooling, automatically activating the cooling mode when the tem- minute units, in a range between 30 minutes and 4 hours. Elimi-
perature rises above the preset maximum temperature setting. nates all anxiety about forgetting to turn off the unit.
Recommended for Meeting room Changing room

Temperature
Temperature Range Restriction prevents Operation Fixed temperature setting promotes
Range
overheating/overcooling Lock energy savings
Restriction

Using a temperature that is 1°C lower/higher for heating/cooling re- In addition to operation start/stop, the operation mode, temperature
sults in a 10% reduction in power consumption.* Temperature setting and airflow direction can be locked. Unwanted adjustment
Range Restriction limits the maximum and minimum temperature of temperature settings is prevented and an appropriate tempera-
settings, contributing to the prevention of overheating/overcooling. ture is constantly maintained, leading to energy savings. This fea-
ture is also useful in preventing erroneous operation or tampering.
*In-house calculations
Recommended for Office School Public hall
Cooling/Dry (Setting example of minimum temp. in 25°C)
Hospital Computer server facility
19(˚C) 30(˚C)
Possible temperature range setting

25(˚C) 30(˚C)
Lower temperature limit
Lower temperatures cannot To prevent excessive cooling
be selected

Recommended for Office Restaurant

Weekly
Set up to 8 patterns per day including temperature control
Timer

The Weekly Timer enables the setting of operation start and finish times and adjusting the temperature as standard features. Up to 8 patterns per
day can be set, providing operation that matches the varying conditions of each period, such as the number of customers in the store.
*Weekly Timer cannot be used when On/Off Timer is in use.

■ Setting Example Preparation


(restaurant in summer time) 26 1 Busy Off-peak Set to higher temperature
Set to lower temperature
hours hours

25 7 8 Closing time
Temperature setting (°C)

Opening
time
24 2 4 6
Lunch time Dinner time
23 3 5

22
8-patterns setting

0
10:00 12:00 14:00 16:00 18:00 20:00 22:00 24:00 (Time)
Necessary to change temperature settings for cooling/heating times.
*Joint research conducted with Japan Facility Solutions, Inc.

24

P003-028.indd 24 13.12.12 1:17:23 PM


CONTROL TECHNOLOGIES

Installation/Maintenance Support Functions


Manual
Outdoor unit data accessed immediately,
Smooth Vane Angle Direction of vertical airflow for each
enabling fast maintenance Setting
Maintenance vane can be set
(only PUHZ type) (4-way ceiling
cassette)

Using the Stable Operation Control (fixed frequency) of the Smooth Setting the vertical airflow direction for each individual vane can be
Maintenance function, the operating status of the inverter can be performed simply via illustrated display. Seasonal settings such as
checked easily via the screen on the remote controller. switching between cooling and heating are easily changed as well.

■ Smooth Maintenance Function Operating Procedure

Auto-
descending Easily raise/lower panels using the
Panel remote controller
Operation
Select the service Activate Stable Auto-descending panel operation is available as an option. Panels
from menu Operation Data is displayed
can be lowered/raised using a button on the wired remote control-
ler. Filter cleaning can be performed easily.
Display information (11 items)
Compressor 6 OU TH4 temp. (°C)
1 COMP. current (A) 7 OU TH6 temp. (°C)
2 COMP. run time (Hr) 8 OU TH7 temp. (°C)
Refrigerant
3 COMP. ON/OFF (times) Indoor Unit
Leakage Easily check refrigerant leakage
4 COMP. frequency (Hz) 9 IU air temp. (°C)
Check
Outdoor Unit 10 IU HEX temp. (°C)
5 Sub cool (°C) 11 IU filter operating time* (Hr)
*IU filter operating time is the time elapsed since filter was reset.
The Mr. Slim Power Inverter units come equipped with a useful
“Refrigerant Leakage Check” function. Using a wired remote con-
troller, it is easy to check if refrigerant has been lost over a long
Inspection Guidelines
The computed temperature difference is plotted as in the graph below and period of use. This reduces service time and gives an added sense
operating status is determined. of safety.
Item
( 6 OU TH4 temp.) – ( 7 OU TH6 temp.)
Cooling
( 9 IU air temp.) – ( 10 IU HEX temp.)
Temp. difference
( 6 OU TH4 temp.) – ( 10 IU HEX temp.)
Heating
( 10 IU HEX temp.) – ( 9 IU air temp.) Silent Mode Three outdoor noise level setting
(°C) (°C)
45 45
Cooling Heating Inspection C
40 40
operation operation The outdoor noise level can be reduced on demand according to the
35 Inspection C 35 Filter inspection
30 30 surrounding environment. Select from three setting mode: standard
25 25
9 10 Filter inspection 10 9 Inspection B mode (rated), silent mode and ultra-silent mode.
20 20 Normal
15 Normal 15
Inspection B
10 10
5 Inspection A 5 Inspection A
0 0
10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80

6 7
(°C)
6 10
(°C)
Initial
Password Password for initial settings
Result
Setting
Normal Normal operating status.
Filter inspection Filter may be blocked.✽1 A password is required (default setting is “0000”) for initial settings
Inspection A Capacity is reduced. Detailed inspection is necessary. such as time and display language.
Inspection B Refrigerant level is low.
Inspection C Filter or indoor unit heat exchanger is blocked.
✽1: Due to indoor and outdoor temperatures, “Filter inspection” may be displayed even if the filter is
not blocked.
✽ The above graphs are based on trial data. Results may vary depending on installation/temperature
conditions.
● Stable operation may not be possible under the following temperature conditions:
a) In cooling mode when the outdoor induction temperature is over 40°C or the indoor induction
temperature is below 23°C.
b) In heating mode when the outdoor induction temperature is over 20°C or when the indoor
induction temperature is over 25°C.
● If the above temperature conditions do not apply and stable operation is not achieved after 30
minutes has passed, please inspect the units.
● The operating status may change due to frost on the outdoor heat exchanger.

25

P003-028.indd 25 13.12.12 1:17:24 PM


Rotation, Back-up and 2nd Stage Cut-in Functions (PAR-31MAA and PAR-21MAA)
(1) Rotation and Back-up Functions Operation Pattern
Function Outline [Back-up function only] Error occurs on main unit.
• Main and sub units take turns operating according Start operation Main Sub
to a rotation interval setting. Main
unit Run Abnormal condition
• If one unit malfunctions, the other unit automati- I/U-1
cally begins operation (Back-up function) Sub
unit Stop Run
System Image I/U-2
O/U-1 O/U-2
Main Sub
unit unit
I/U-1 I/U-2
[Rotation function] & [Back-up function]
Error occurs on main unit.
Start operation Main Sub Sub Main Main Sub
Main
O/U : Outdoor unit unit
I/U : Indoor unit Run Stop Run Abnormal condition
R/C I/U-1
R/C : Wired remote controller
Sub
(2) 2nd Stage Cut-in Function unit Stop Run Stop Run
I/U-2
Function Outline
1–28 days 1–28 days
• Number of units operating is based on room tem- (Ex: When the request code is “313”, each unit operates alternately in daily cycle.)
perature and predetermined settings.
• When room temperature rises above the desired Operation Pattern
setting, the standby unit starts (2-unit operation). [2nd stage cut-in function]
Room temp. > Room temp. >
= Set point = Set point –4°C
• When the room temperature falls 4°C below the Start operation Sub unit starts operation Sub unit stops
predetermined setting, the standby unit stops (1- Main
unit Run
unit operation). I/U-1
System Constraint Sub
• This function is only available for rotation operation unit Stop Run Stop
I/U-2
and when the back-up function is in cooling mode.

New
New Simple MA Remote Controller
PAC-YT52CRA

Backlit LCD Flat 120mm


back (4-23/32 in)
Features a liquid-crystal display (LCD) with backlight
for operation in dark conditions.

Flat Back
The slim and flat-back shape makes installation
easier without requiring a hole in the wall. Thickness
is 14.5mm or less.

Vane Angle Setting


The vane button has been added to allow users to Max 70mm (2-3/4 in)
change the airflow direction (ceiling-cassette and 14.5mm (9/16 in)
wall-mounted units).

Pressing the button will switch


the vane direction. AUTO Setting 1 Setting 2 Setting 3 Setting 4 Setting 5 Swing

* The settable vane directions vary depending on the indoor unit model to be connected.
* If the unit has no vane function, the vane direction cannot be set. In this case, the vane icon flashes when the button is pressed.

26

P003-028.indd 26 13.12.12 1:17:24 PM


SYSTEM CONTROL
Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.

MAJOR SYSTEM CONTROL

System Examples

Indoor Unit M Series Indoor Unit S Series & P Series Indoor Unit P Series Indoor Unit

Outdoor Unit M Series and MXZ Series Outdoor S Series and MXZ Series Outdoor P Series Outdoor

Indoor unit
MAC-333IF-E
MAC-397IF-E

Indoor unit

PAR-31MAA Control
Outdoor unit PAR-31MAA
PAC-YT52CRA Control PAC-YT52CRA
PAR-31MAA
PAC-YT52CRA

Outdoor unit

Details • Wired remote controller can be connected to


Standard equipment (for indoor units compatible with wired remote controllers)
indoor unit

• MAC-333IF-E or MAC-397IF-E (Interface)


• PAR-31MAA (Wired remote controller)
Major Optional Parts Required • PAR-31MAA (Wired remote controller)
• PAC-YT52CRA (Wired remote controller)
• PAC-YT52CRA (Wired remote controller)

Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit

MAC-333IF-E MAC-333IF-E
MAC-397IF-E MAC-397IF-E

System Group Control PAR-31MAA


PAR-31MAA PAR-31MAA PAC-YT52CRA
Outdoor unit Outdoor unit PAC-YT52CRA PAC-YT52CRA
Outdoor unit Outdoor unit Outdoor unit Outdoor unit

• One remote controller can control plural air conditioners with the same settings simultaneously.
Details • One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-333IF-E or MAC-397IF-E is counted as one system.)
• Up to two remote controller can be connected.

• MAC-333IF-E or MAC-397IF-E (Interface)


• PAR-31MAA (Wired remote controller)
Major Optional Parts Required • PAR-31MAA (Wired remote controller)
• PAC-YT52CRA (Wired remote controller)
• PAC-YT52CRA (Wired remote controller)

Outdoor Outdoor
Outdoor unit unit unit
Outdoor unit Outdoor unit

Indoor unit Indoor unit PAC-SC51KUA


Indoor unit Power supply Indoor unit Indoor unit
kit
City Multi City Multi PAR-31MAA PAR-31MAA
indoor unit indoor unit PAC-YT52CRA PAC-YT52CRA
PAR-31MAA PAR-31MAA
MELANS PAC-YT52CRA PAC-YT52CRA
M-NET Connections MAC-333IF-E
system controller
(AG-150A etc) MAC-333IF-E Outdoor Outdoor
MELANS
system controller unit unit
PAC-SC51KUA
Power supply (AG-150A etc) M-NET adapter
unit MELANS PAC-SF83MA-E
ME remote controller system controller
PAC-SC51KUA PAC-SJ19MA-E
(PAR-F27MEA) Power supply (AG-150A etc)
unit

Details • Group of air conditioners can be controlled by MELANS system controller (M-NET).

• PAC-SF83MA-E or PAC-SJ19MA-E
• MAC-333IF-E (M-NET Interface)
(M-NET converter)
Major Optional Parts Required • MELANS System controller
• MELANS System controller
• PAC-SC51KUA (power supply unit)
• PAC-SC51KUA (power supply unit)

27

P003-028.indd 27 13.12.12 1:17:25 PM


OTHERS
For M Series Indoor Units (New A-control Models Only)

System Examples Connection Details Control Details Major Optional Parts Required

Remote On/Off Connect the interface to the air On/Off operation is possible from • MAC-333IF-E or MAC-397IF-E
1 Operation
MAC-333IF-E
MAC-397IF-E conditioner. Then connect the a remote location. (Interface)
locally purchased remote controller • Parts for circuit such as relay
• Air conditioner can be started/ to the terminal in the interface. box, lead wire, etc. (to be
Switch
stopped remotely. Indoor unit
purchased locally)
( 1 and 2 can be used in Remote control section
combination) Outdoor unit (to be purchased locally)

Remote Display of Connect the interface to the air The operation status • MAC-333IF-E or MAC-397IF-E
2 Operation Status
MAC-333IF-E
MAC-397IF-E
Power supply
conditioner. Then connect the (On/Off) or error signals can be (Interface)
locally purchased remote controller monitored from a remote location. • Parts for circuit to be
• The On/Off status of air to the terminal in the interface. purchased locally (DC power
Resistance LED
conditioners can be confirmed Indoor unit
source needed)
remotely. Remote monitor section • External power source (12V DC)
( 1 and 2 can be used in Outdoor unit (to be purchased locally)
is required when using
combination) MAC-333IF-E.

For P Series and S Series Indoor Units


System Examples
Details Major Optional Parts Required
Wired remote controller Wireless remote controller

2-remote Controller • Up to two remote controllers can be • Wired Remote Controller


A Control connected to one group. PAR-31MAA
PAC-YT52CRA
With two remote controllers, control PAR-SL97A-E
(for PKA, PAC-SH29TC-E is required)
can be performed locally and PAR-31MAA
PAR-31MAA • Wireless Remote Controller
remotely from two locations. PAC-YT52CRA
PAR-SL97A-E (Except for SLZ)
PAC-YT52CRA • Both wired and wireless remote controllers
* Set "Main" and "Sub"
* When using wired and can be used in combination. • Wireless Remote Controller Kit for PCA
remote controllers.
wireless remote controllers PAR-SL99B-E
(Example of 1 : 1 system) (Example of Simultaneous Twin)

Relay box (to be purchased) locally) Relay box (to be purchased locally)
Operation Control by • Operation other than On/Off (e.g., adjust- • Adapter for remote On/Off
B Level Signal Adapter for Adapter for ment of temperature, fan speed, and airflow) PAC-SE55RA-E
remote remote
On/Off On/Off can be performed even when remote • Relay box (to be purchased locally)
Air conditioner can be started/ • Remote control panel (to be purchased
controller operation is prohibited.
stopped remotely. In addition, locally)
• Timer control is possible with an external
On/Off operation by local remote Remote Remote
control control timer.
controller can be prohibited/permitted. panel Wired remote panel PAR-SL97A-E
controller
(Example of 1 : 1 system x 2) (Example of 1 : 1 system x 2)

Relay box (to be purchased) locally) Relay box (to be purchased locally)
Operation Control by • The pulse signal can be turned On/Off. • Connector cable for remote display
C Pulse Signal Connector Connector • Operation/emergency signal can be PAC-SA88HA-E / PAC-725AD
cable for cable for
remote remote received at a remote location. (10 pcs. x PAC-SA88HA-E)
display display • Relay box (to be purchased locally)
• Remote control panel (to be purchased
Remote Remote
control control locally)
panel Wired remote panel PAR-SL97A-E
controller
(Example of 1 : 1 system x 2) (Example of 1 : 1 system x 2)

Remote operation adapter/ Remote operation adapter/


Remote Display of Connector cable for remote display + Connector cable for remote display + • Operation/emergency signal can be • Remote display panel (to be purchased
D Operating Status
Relay box Relay box
received at a remote location (when locally)
channeled through the PAC-SF40RM-E • Connector cable for remote display
Operating status can be no-voltage signal, when channeled through PAC-SA88HA-E / PAC-725AD
displayed at a remote location. the PAC-SA88HA-E DC 12V signal). (10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote operation adapter
Remote
display Remote PAC-SF40RM-E
panel display
panel *Unable to use with wireless remote controller
PAR-SL97A-E
PAR-31MAA /PAC-YT52CRA
(Example of 1 : 1 system) (Example of Simultaneous Twin)

• Weekly Timer: Standard functions of


E Timer Operation On/Off and up to 8 pattern temperatures can PAR-31MAA
be set for each calendar day. (Initial setting)
Allows On/Off operation with • On/Off Timer:
timer On/Off can be set once each within 72 hr in
*For control by an external PAR-31MAA intervals of 5-minute units.
timer, refer to B Operation • Auto-off Timer:
Control by Level Signal. (Example of 1 : 1 system) Operation will be switched off after a certain
time elapse. Set time can be changed from
30 min. to 4 hr. at 10 min. intervals.
*Simple Timer and Auto-off Timer
cannot be used at the same time.

28

P003-028.indd 28 13.12.12 1:17:25 PM


SERIES

29

P029-048.indd 29 13.12.12 1:18:31 PM


SELECTION
Choose the model that best matches room conditions.

STEP 1 SELECT SERIES


A multiple series line-up to choose from, each with various outstanding features. In addition to inverter-equipped models,
constant-speed, floor-standing and cassette models can be selected. Choose the best series to match usage needs.

Wall-mounted Units

MSZ-F SERIES MSZ-E SERIES

25/35 25/35 25/35 25/35 25/35


Super SEER SCOP Cooling SEER SCOP Cooling
energy- Ultra-quiet
saving A+++ A+++ Heating
A+++ A++ Heating

MSZ-S SERIES MSZ-G SERIES MSZ-H SERIES

50 50
SEER SCOP Cooling SEER SCOP Cooling SEER SCOP Cooling
A++ A+ Heating A++ A+ Heating A+ A+ Heating

Floor-standing Cassette Units

MFZ SERIES MLZ SERIES

25
SEER SCOP
Cooling
Heating A+++ A+++
Cooling
Heating ✽ MXZ connection only

Super SEER SCOP


Inverter A Energy Rank Ultra-quiet operation Cooling
energy-
saving
Super energy-saving A Ultra-quiet Heating Cooling and heating operation

Compatible for connection to MXZ Series system ✽ To confirm compatibility with the MXZ Series multi-type system, refer to the MXZ Series page.

STEP 2 SELECT OUTDOOR UNIT


Some outdoor units in the line-up have heaters for use in cold regions. Units with an “H” in the model name are equipped with heaters.

Heater Installed

MUZ-FH25/35VEHZ
MUZ-EF25/35VEH MUZ-FH50VEHZ
MUZ-SF25/35/42VEH MUZ-SF50VEH
MUFZ-KJ25/35VEHZ MUFZ-KJ50VEHZ
Selecting a Heater-equipped Model
In regions with the following conditions, there is a possibility that water resulting from condensation on the outdoor unit when operating in the heating
mode will freeze and not drain from the base.
1) Cold outdoor temperatures (temperature does not rise above 0 oC all day)
2) Areas where dew forms easily (in the mountains, valleys(surrounded by mountains), near a forest, near unfrozen lakes, ponds, rivers or hot springs),
or areas with snowfall
To prevent water from freezing in the base, it is recommended that a unit with a built-in heater be purchased. Please ask your dealer representative about
the best model for you.

30

P029-048.indd 30 13.12.12 1:18:33 PM


MSZ-FH25/35/50VE

MSZ-F SERIES
The F Series is designed for optimum cooling/heating performance as well as operational
comfort. Quiet, energy-saving operation is supported by some of Mitsubishi Electric’s latest
technologies. Advanced functions such as “3D i-see Sensor” temperature control and the
Plasma Quad air purification system raise room comfort levels to new heights.

25/35 25/35

SEER SCOP
High Energy Efficiency A +++
A+++

Power consumption has been reduced for the cooling and heating SEER Cooling
9.1 SEER
modes thanks to the incorporation of our newest inverter 8.9 Heating
technologies. The high energy efficiency of the Size 25 units has SEER
SCOP SCOP 7.2
obtained a rating of more than 5.0 for both seasonal coefficient of 5.1 5.1 SCOP
performance (SCOP) and seasonal energy efficiency rating (SEER). 4.6 SEER Rank A(5.1)

SCOP Rank A(3.4)

MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE

Hyper Heating
The Hyper Heating feature is incorporated, realizing powerful heating even in the harsh cold. Even users in cold regions can comfort-
ably rely on the MSZ-FH Series for all their heating needs.

Operation Guaranteed at Rated Capacity Demonstrated at Freeze-prevention Heater


Outside Temperature of -25°C Outside Temperatures of -15°C Equipped as Standard (VEHZ)
MUZ-FH VEHZ can be operated at outside tempera- With rated capacity ensured at outside temperature The Freeze-prevention heater prevents lowered
tures as low as -25°C, so there are no concerns as low as -15°C, the FH Series can be relied upon to capacity due to the drain freezing and also inhibits
about use even in very cold climates. properly warm living spaces even in severe cold operation shutdowns.
snaps.

Frozen drain Drain does not freeze

MUZ-FH VE 4.0
3.2 3.2 kW
MUZ-FH VEHZ 2.5 kW kW
kW
-25oC -20oC -15oC -10oC
MUZ-FH25VE MUZ-FH25VEHZ MUZ-FH35VE MUZ-FH35VEHZ
Without Freeze-prevention heater With Freeze-prevention heater

Selecting a Heater-equipped Model


In regions with the following conditions, there is a possibility that water resulting from condensation on the outdoor unit when operating in the
heating mode will freeze and not drain from the base.
1) Cold outdoor temperatures (temperature does not rise above 0°C all day)
2) Areas where dew forms easily (in the mountains, valleys(surrounded by mountains), near a forest, near unfrozen lakes, ponds, rivers or hot
springs), or areas with snowfall
To prevent water from freezing in the base, it is recommended that a unit with a built-in heater be purchased. Please ask your dealer representative
about the best model for you.

31

P029-048.indd 31 13.12.12 1:18:35 PM


Air, like water, is something we use everyday unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans.
Achieving this healthy air is Plasma Quad, a plasma-based filter system that effectively removes four kinds of air pollutants; namely, bacte-
ria, viruses, allergens and dust, which the air contains countless particles of.

Bacteria Viruses
Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad
neutralizes 99% of bacteria in 115 minutes in a neutralizes 99% of virus particles in 65
25m3 test space. minutes in a 25m3 test space.
Plasma Quad off Plasma Quad on Without Plasma Quad With Plasma Quad

* Hepatic cells turn transparent when affected by a virus.


〈Test No.〉
KRCES-Bio.Test Report No.23_0371
〈Test No.〉
vrc.center, SMC No.23-002

Effective deodorizing using


the air-purifying filter

Dust
Allergens In a test, air containing dust and ticks was
passed through the air cleaning device at the
In a test, air containing cat fur and pollen was
low airflow setting. Before and after measure-
passed through the air cleaning device at the
ments confirm that Plasma Quad removes
low airflow setting. Before and after measure-
88.6% of dust and ticks.
ments confirm that Plasma Quad neutralizes
94% of cat fur and 98% of pollen. 〈Test No.〉
ITEA No.12M-RPTFEBO22

〈Test No.〉
ITEA No.12M-RPTFEBO22 (Image)

Principle of Plasma Quad


[ Effective Range ]
Plasma Quad attacks bacteria and viruses from inside the unit using a strong curtain-like
electrical field and discharge of electric current across the whole inlet-air opening of the
unit. Tungsten discharge electrodes are used as they provide both discharge capacity and
Macro Particulate size Nano strength. In addition, through flattening the standard, round form of the field to a ribbon-like
shape, a strong electrical field is produced.
Dust Allergens Viruses Bad Odours Round:
Air
Dust
Viruses Virus Bacteria

Pollen Bacteria Pet odours Fish odours


Plasma
field
Mold spores Rubbish odours Flattened: a strong electrical field is produced.

Neutralization/inactivation
Plasma Quad Air-purifying filter
Air

32

P029-048.indd 32 13.12.12 1:18:35 PM


The FH Series is equipped with 3D i-see Sensor, an infrared-ray Indirect Airflow Direct Airflow
sensor that measures the temperature at distant positions. While The indirect airflow setting can be used This setting can be used to directly target
when the flow of air feels too strong or airflow at people such as for immediate
moving to the left and right, eight vertically arranged sensor elements
direct. For example, it can be used during comfort when coming indoors on a hot
analyze the room temperature in three dimensions. This detailed cooling to avert airflow and prevent body (cold) day.
analysis makes it possible to judge where people are in the temperature from becoming excessively
cooled.
room, thus allowing creation of features such as “Indirect airflow,”
to avoid airflow hitting people directly, and “direct airflow” to deliver
airflow to where people are.

Sensor with
eight elements
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode.

8 × 94 areas

Sensor measures while


moving to the left to right

Divided into 94
The “3D i-see Sensor” detects people’s absence and the power consumption is automatically reduced
(Image) approximately 10% after 10 minutes and 20% after 60 minutes.

Natural Flow 24-hour Timer

To create “healthy” airflow, the most important aspect is that the flow
of air feels natural. Mitsubishi Electric’s solution to this is Natural Flow,
only possible thanks to our technology that freely and flexibly controls
airflow.

Natural Flow (in Cooling)


40.0

Double Vane
Mitsubishi Electric’s double
vane separates the airflow
23.0
in the left and right directions
Gentle airflow that avoids overcooling to deliver airflow not only
across a wide area of the
Direct airflow (in Cooling) room, but also simultaneously
40.0
to two people in different
locations.

Through realizing airflow that imitates a


natural breeze, we have avoided the
unpleasant feeling of being hit directly
23.0
Legs become too cold by constant, unnatural airflow.

Base data for Natural Flow


Analysis of natural wind
Kirigamine Highland is one of the most Wind speed [cm/s]
famous sightseeing spots in Japan, and 140
is visited by a large number of people 120
for its pleasant and comfortable environ-
100
ment. At Mitsubishi Electric, we have
80
attempted to recreate this Kirigamine
Highland comfort. As part of development, 60

seeking to create a natural airflow, we 40


measured actual data on the refreshing 20
breezes of Kirigamine Highland. Through 0
imitating the natural waveforms of this 0 20 40 60 80 100 120
Time [s]
data, we have been able to recreate
Wind of Kirigamine Natural Flow(FH SERIES)
Kirigamine Highland measuring actual data
almost-imperceptible currents of gently
of natural wind comforting airflow.

33

P029-048.indd 33 13.12.12 1:18:36 PM


25 / 35 25 / 35

SEER SCOP
MSZ-F SERIES Please fill out the requested information
Please fill out the requested information A +++
A+++

Indoor Unit Outdoor Unit Remote Controller

MUZ-FH25/35VE
MSZ-FH25/35/50VE

MUZ-FH50VE

HUMAN Natural Flow


VERTICAL HORIZONTAL 24-hour Timer

Wi-Fi
Interface
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE
Outdoor Unit MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
Refrigerant R410A(*1)
Power Source Outdoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230/Single/50
Design load kW 2.5 3.5 5.0
Annual electricity consumption (*2) kWh/a 96 138 244
SEER (*4) 9.1 8.9 7.2
Cooling Energy efficiency class A+++ A+++ A++
Rated kW 2.5 3.5 5.0
Capacity
Min-Max kW 1.4-3.5 0.8-4.0 1.9-6.0
Total Input Rated kW 0.485 0.820 1.380
Design load kW 3.0(-10°C) 3.6(-10°C) 4.5(-10°C)
at reference design temperature kW 3.0(-10°C) 3.6(-10°C) 4.5(-10°C)
Declared
at bivalent temperature kW 3.0(-10°C) 3.6(-10°C) 4.5(-10°C)
Capacity
at operation limit temperature kW 2.5(-15°C) 3.2(-15°C) 5.2(-15°C)
Heating Back up heating capacity kW 0.0(-10°C) 0.0(-10°C) 0.0(-10°C)
(Average Annual electricity consumption (*2) kWh/a 819 986 1372
Season)(*5) SCOP (*4) 5.1 5.1 4.6
Energy efficiency class A+++ A+++ A++
Rated kW 3.2 4.0 6.0
Capacity
Min-Max kW 1.8-5.5 1.0-6.3 1.7-8.7
Total Input Rated kW 0.580 0.800 1.480
Operating Current (Max) A 9.6 10.0 14.0
Input Rated kW 0.029 0.029 0.031
Operating Current(Max) A 0.4 0.4 0.4
Dimensions H*W*D mm 305(+17)-925-234 305(+17)-925-234 305(+17)-925-234
Weight kg 13.5 13.5 13.5
Indoor
Air Volume (SLo-Lo- Cooling m3/min 3.9-4.7-6.3-8.6-11.6 3.9-4.7-6.3-8.6-11.6 6.4-7.4-8.6-10.1-12.4
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 4.0-4.7-6.4-9.2-13.2 4.0-4.7-6.4-9.2-13.2 5.7-7.2-9.0-11.2-14.6
Sound Level (SPL) Cooling dB(A) 20-23-29-36-42 21-24-29-36-42 27-31-35-39-44
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 20-24-29-36-44 21-24-29-36-44 25-29-34-39-46
Sound Level (PWL) Cooling dB(A) 58 58 60
Dimensions H*W*D mm 550-800-285 550-800-285 880-840-330
Weight kg 37 37 55
Cooling m3/min 31.3 33.6 48.8
Air Volume
Heating m3/min 31.3 33.6 51.3
Outdoor
Cooling dB(A) 46 49 51
Unit Sound Level (SPL)
Heating dB(A) 49 50 54
Sound Level (PWL) Cooling dB(A) 60 61 64
Operating Current (Max) A 9.6 9.6 13.6
Breaker Size A 9.2 10 16
Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35 / 12.7
Ext.
Max.Length Out-In m 20 20 30
Piping
Max.Height Out-In m 12 12 15
Guaranteed Operating Cooling ˚C -10 ~ +46 -10 ~ +46 -10 ~ +46
Range (Outdoor) Heating ˚C -15 ~ +24 -15 ~ +24 -15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifications.
34

P029-048.indd 34 13.12.12 1:18:38 PM


MSZ-EF18-50VE2B

MSZ-E
Developed to complement modern interior room décor, Kirigamine
ZEN air conditioners are available in three colours specially chosen
SERIES

to blend in naturally wherever installed.

Stylish Line-up Matches


Any Room Décor
The streamlined wall-mounted indoor units have eloquent
silver-bevelled edges, expressing sophistication and quality.
Combining impressively low power consumption and quiet
yet powerful performance, these units provide a best-
match scenario for diverse interior designs while simultane-
ously ensuring maximum room and energy savings.

25-35 25-42*

SEER SCOP
Energy-efficient Operation A +++
A++
*except for VEH

All models in the series have achieved high energy-savings rating, and are contributing to reduced energy consumption in homes, offices and a range
of other settings. Offered in a variety of output capacities and installation patterns, the vast applicability promises an ideal match for any user.

Outdoor Rank A for single connection Compatibility


MUZ-EF25/35VE(H) MXZ
Indoor MUZ-EF42/50VE 2D33VA 2D40VA 2D53VA 3D54VA 3D68VA 4D72VA 4D83VA 5D102VA 6C122VA
MSZ-EF18VE2 –
MSZ-EF22VE2 –
MSZ-EF25VE2 A + + + / A++(A++*)
MSZ-EF35VE2 A + + + / A++(A+*)
MSZ-EF42VE2 A + + / A++
MSZ-EF50VE2 A + + / A+
*VEH

Quiet Comfort All Day Long Low Standby Power


Mitsubishi Electric’s advanced “Silent Mode” fan speed setting pro- Electrical devices consume standby power even when they are not
vides super-quiet operation as low as 21dB for EF18/22/25/35 in actual use. While we obviously strive to reduce power consump-
models. This unique feature makes the Kirigamine ZEN series ideal tion during actual use, reducing this wasted power that cannot be
for use in any situation. seen is also very important.

● Noise Level Human


Quiet passenger
Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet) without around 10W
“Low standby power”

80dB 60dB 40dB 10dB around


with below
90%
Only 21dB
(for EF18/22/25/35 models)
“Low standby power” 1W reduction
Superior Exterior
and Operating Design Concept
The indoor unit of the Kirigamine ZEN keeps its amazingly thin form
Outdoor Units for Cold Region (25/35)

even during operation. The only physical change notable is the Single split-type outdoor units are available in both standard and
movement of the variable vent. As a result, a slim attractive look is heater-equipped units. An electric heater is installed in each unit to
maintained. prevent freezing in cold outdoor environments.
Standard Units Heater Installed
Closed Open

MUZ-EF25/35VE MUZ-EF25/35VEH

35

P029-048.indd 35 13.12.12 1:18:40 PM


25 - 35 25 - 42*

SEER SCOP
MSZ-E SERIES Please fill out the requested information
Please fill out the requested information
A +++
A++
*except for VEH

Indoor Unit Outdoor Unit Remote Controller

MSZ-EF18/22/25/35/42/50VE2W White

MUZ-EF25/35VE(H),42VE

MSZ-EF18/22/25/35/42/50VE2S Silver

MSZ-EF18/22/25/35/42/50VE2B* Black MUZ-EF50VE

*Soft-dry Cloth is enclosed with Black models.

Electrostatic Wi-Fi
Anti-allergy Interface
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MSZ-EF18VE2 MSZ-EF22VE2 MSZ-EF25VE2 MSZ-EF25VE2 MSZ-EF35VE2 MSZ-EF35VE2 MSZ-EF42VE2 MSZ-EF50VE2
Outdoor Unit for MXZ connection MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE
Refrigerant R410A(*1)
Power Source Outdoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230/Single/50
Design load kW - - 2.5 2.5 3.5 3.5 4.2 5.0
Annual electricity consumption (*2) kWh/a - - 103 103 144 144 192 244
SEER (*4) - - 8.5 8.5 8.5 8.5 7.7 7.2
Cooling Energy efficiency class - - A+++ A+++ A+++ A+++ A++ A++
Rated kW - - 2.5 2.5 3.5 3.5 4.2 5.0
Capacity
Min-Max kW - - 1.2-3.4 1.2-3.4 1.4-4.0 1.4-4.0 0.9-4.6 1.4-5.4
Total Input Rated kW - - 0.545 0.545 0.910 0.910 1.280 1.560
Design load kW - - 2.4(-10ºC) 2.4(-10ºC) 2.9(-10ºC) 2.9(-10ºC) 3.8(-10ºC) 4.2(-10ºC)
at reference design temperature kW - - 2.4(-10ºC) 2.4(-10ºC) 2.9(-10ºC) 2.9(-10ºC) 3.8(-10ºC) 4.2(-10ºC)
Declared
at bivalent temperature kW - - 2.4(-10ºC) 2.4(-10ºC) 2.9(-10ºC) 2.9(-10ºC) 3.8(-10ºC) 4.2(-10ºC)
Capacity
at operation limit temperature kW - - 2.0(-15ºC) 1.6(-20ºC) 2.4(-15ºC) 1.7(-20ºC) 3.4(-15ºC) 3.5(-15ºC)
Heating Back up heating capacity kW - - 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC)
(Average Annual electricity consumption (*2) kWh/a - - 716 730 882 910 1155 1309
Season)(*5) SCOP (*4) - - 4.7 4.6 4.6 4.5 4.6 4.5
Energy efficiency class - - A++ A++ A++ A+ A++ A+
Rated kW - - 3.2 3.2 4.0 4.0 5.4 5.8
Capacity
Min-Max kW - - 1.1-4.2 1.1-4.2 1.8-5.5 1.8-5.5 1.4-6.3 1.6-7.5
Total Input Rated kW - - 0.700 0.700 0.955 0.955 1.460 1.565
Operating Current (Max) A - - 7.3 7.3 8.5 8.5 9.5 12.4
Input Rated kW 0.027 0.027 0.027 0.027 0.031 0.031 0.031 0.034
Operating Current(Max) A 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4
Dimensions H*W*D mm 299-895-195 299-895-195 299-895-195 299-895-195 299-895-195 299-895-195 299-895-195 299-895-195
Weight kg 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5
Indoor
Air Volume (SLo-Lo- Cooling m3/min 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 5.8 - 6.6 - 7.7 - 8.9 - 10.3 5.8 - 6.8 - 7.9 - 9.3 - 11.0
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 4.0 - 4.6 - 6.2 - 8.9 - 11.9 4.0 - 4.6 - 6.2 - 8.9 - 11.9 4.0 - 4.6 - 6.2 - 8.9 - 11.9 4.0 - 4.6 - 6.2 - 8.9 - 11.9 4.0 - 4.6 - 6.2 - 8.9 - 12.7 4.0 - 4.6 - 6.2 - 8.9 - 12.7 5.5 - 6.3 - 7.8 - 9.9 - 12.7 6.4 - 7.3 - 9.0 - 11.1 - 13.2
Sound Level (SPL) Cooling dB(A) 21 - 23 - 29 - 36 - 42 21 - 23 - 29 - 36 - 42 21 - 23 - 29 - 36 - 42 21 - 23 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 28 - 31 - 35 - 39 - 42 30 - 33 - 36 - 40 - 43
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 21 - 24 - 29 - 37 - 45 21 - 24 - 29 - 37 - 45 21 - 24 - 29 - 37 - 45 21 - 24 - 29 - 37 - 45 21 - 24 - 30 - 38 - 46 21 - 24 - 30 - 38 - 46 28 - 30 - 35 - 41 - 48 30 - 33 - 37 - 43 - 49
Sound Level (PWL) Cooling dB(A) - - 60 60 60 60 60 60
Dimensions H*W*D mm - - 550-800-285 550-800-285 550-800-285 550-800-285 550-800-285 880-840-330
Weight kg - - 30 30 35 35 35 54
Cooling m3/min - - 32.6 32.6 33.6 33.6 35.2 44.6
Air Volume
Heating m3/min - - 32.2 32.2 33.6 33.6 33.6 44.6
Outdoor
Cooling dB(A) - - 47 47 49 49 50 52
Unit Sound Level (SPL)
Heating dB(A) - - 48 48 50 50 51 52
Sound Level (PWL) Cooling dB(A) - - 58 58 61 61 62 65
Operating Current (Max) A - - 7.0 7.0 8.2 8.2 9.2 12.0
Breaker Size A - - 10 10 10 10 10 16
Diameter Liquid/Gas mm - - 6.35 / 9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7
Ext.
Max.Length Out-In m - - 20 20 20 20 20 30
Piping
Max.Height Out-In m - - 12 12 12 12 12 15
Guaranteed Operating Cooling ˚C - - -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46
Range (Outdoor) Heating ˚C - - -15 ~ +24 -20 ~ +24 -15 ~ +24 -20 ~ +24 -15 ~ +24 -15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifications.
36

P029-048.indd 36 13.12.12 1:18:42 PM


MSZ-SF15/20VA

MSZ-S SERIES MSZ-SF25/35/42/50VE

MSZ-G
MSZ-GF60/71VE

SERIES
Introducing a compact and stylish indoor unit with amazingly quiet performance.
Not only are neat installations in small bedrooms possible, increase energy-savings
by selecting the optimal capacity required for each room.

25-71 25-71
SEER SCOP
++ +
“Rank A /A ” Energy Savings Achieved for Entire Range of Series A ++
A+

All models in the series, from the low-capacity 25 to the high-capacity 71, have achieved the “Rank A++” for SEER and “Rank A+” for SCOP as en-
ergy-savings rating. For home use, such as in bedrooms and living rooms, to light commercial use, such as in offices, our air conditioners are con-
tributing to reduced energy consumption in a wide range.
Cooling Heating
SEER SEER
7.6 SEER SEER SEER
7.2 7.5 7.2 SEER
6.8 6.8
SCOP SCOP SCOP SCOP SCOP SCOP
4.4 4.4 4.4 4.4 4.3 4.2
SEER Rank A(5.1)

SCOP Rank A(3.4)

MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE MSZ-GF60VE MSZ-GF71VE

Wide Line-up
Eight different indoor units (Model 15-71) are available to meet your diversified air conditioning needs.

MSZ-SF15 / 20VA* MSZ-SF25 / 35 / 42 / 50VE MSZ-GF60 / 71VE


*for MXZ connection

Compact and Stylish (MSZ-SF15/20VA) Family Design (MSZ-SF15/20/25/35/42/50)

The stylish, square indoor unit adds a touch of class to any room in- Models in the 25-50 class are introduced as single-split units while
terior. The compact design is 64mm thinner than our previous retaining the popular design of the SF15/20VA* as indoor units
indoor unit with the lowest output capacity (MSZ-GE22VA). exclusively for multi-systems. From small rooms to living rooms, it
is possible to coordinate residences with a unified design.
*Size may vary.
Comparison with our previous model GE

45mm less

64mm less 38mm less

37

P029-048.indd 37 13.12.12 1:18:45 PM


“Weekly Timer”
Easily set desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
■ Example Operation Pattern (Winter/Heating mode)
Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C
Automatically changes to high-power operation at wake-up time

OFF OFF OFF OFF OFF ON 18°C ON 18°C


Midday is warmer,
Automatically turned off during work hours so the temperature is set lower

ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C


Automatically raises temperature setting to
Automatically turns on, synchronized with arrival at home match time when outside-air temperature is low
(during sleeping hours)
ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C
Automatically lowers temperature at bedtime for energy-saving operation at night

Pattern Settings: Input up to four settings for each day


Settings
Settings: • Start/Stop operation • Temperature setting ✽ The operation mode cannot be set.

■ Easy set-up using dedicated buttons


PUSH PUSH PUSH
The remote controller is How to set
equipped with buttons that the Weekly
are used exclusively for Timer Select the day Select the period
setting the Weekly Timer. Ready to set
Setting operation patterns
is easy and quick.
PUSH
PUSH PUSH PUSH

Complete Select ON/OFF Select the time Set the temperature

• Start by pushing the “SET” button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the
indoor unit and push the “SET” button one more time. (Push the “SET” button only after in-
putting all of the desired patterns into the remote controller memory. Pushing the “CANCEL”
button will end the set-up process without sending the operation patterns to the indoor unit).
• It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.
• When “Weekly Timer” is set, temperature can not be set 10°C.

Low Standby Power


Electrical devices consume standby power even when they are not in actual use. without around 10W
While we obviously strive to reduce power consumption during actual use, “Low standby power”
reducing this wasted power that cannot be seen is also very important.
around
with below
90%
“Low standby power” 1W reduction

Nano Platinum Filter (MSZ-SF25/35/42/50,MSZ-GF60/71) “i save” Mode


This filter incorporates nanometre-sized platinum-ceramic particles “i save” is a simplified setting function that recalls the preferred
that generate stable antibacterial and deodourising effects. The size (preset) temperature by pressing a single button on the remote con-
of the three-dimensional surface has been increased as well, enlarg- troller. Press the same button twice in repetition to immediately
ing the filter capture area. These features give the Nano Platinum return to the previous temperature setting. Using this function con-
Filter better dust collection performance than conventional filters. tributes to comfortable, waste-free operation, realising the most
The superior air-cleaning effectiveness raises room comfort yet an- suitable air conditioning settings and saving on power consumption
other level. when, for example, leaving the room or going to bed.

Heating Heating

22°C 18°C

✽ It is okay to wash the filter with water


(air-cleaning effect is maintained) 3D surface (Waved surface)

✽ Temperature can be preset to 10°C when heating in the “i-save” mode


(except when connected to MXZ-8B140VA/YA, MXZ-8B160VA/YA).

Outdoor Units for Cold Region (25/35/42/50) Standard Units Heater Installed

Single split-type outdoor units are available in both standard and


heater-equipped units. An electric heater is installed in each unit to
prevent freezing in cold outdoor environments.

MUZ-SF25/35/42VE MUZ-SF50VE MUZ-SF25/35/42VEH MUZ-SF50VEH

38

P029-048.indd 38 13.12.12 1:18:47 PM


MSZ-S SERIES

Indoor Unit Outdoor Unit Remote Controller

For MXZ Connection Only

MSZ-SF15/20VA

Wi-Fi
Interface
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MSZ-SF15VA MSZ-SF20VA MSZ-SF25VE MSZ-SF25VE MSZ-SF35VE MSZ-SF35VE
Outdoor Unit for MXZ connection MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH
Refrigerant R410A(*1)
Power Source Outdoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230/Single/50
Design load kW - - 2.5 2.5 3.5 3.5
Annual electricity consumption (*2) kWh/a - - 116 116 171 171
SEER (*4) - - 7.6 7.6 7.2 7.2
Cooling Energy efficiency class - - A++ A++ A++ A++
Rated kW - - 2.5 2.5 3.5 3.5
Capacity
Min-Max kW - - 0.9-3.4 0.9-3.4 1.1-3.8 1.1-3.8
Total Input Rated kW - - 0.600 0.600 1.080 1.080
Design load kW - - 2.4(-10ºC) 2.4(-10ºC) 2.9(-10ºC) 2.9(-10ºC)
at reference design temperature kW - - 2.4(-10ºC) 2.4(-10ºC) 2.9(-10ºC) 2.9(-10ºC)
Declared
at bivalent temperature kW - - 2.4(-10ºC) 2.4(-10ºC) 2.9(-10ºC) 2.9(-10ºC)
Capacity
at operation limit temperature kW - - 2.0(-15ºC) 1.6(-20ºC) 2.2(-15ºC) 1.6(-20ºC)
Heating Back up heating capacity kW - - 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC)
(Average Annual electricity consumption (*2) kWh/a - - 764 790 923 948
Season)(*5) SCOP (*4) - - 4.4 4.3 4.4 4.3
Energy efficiency class - - A+ A+ A+ A+
Rated kW - - 3.2 3.2 4.0 4.0
Capacity
Min-Max kW - - 1.0-4.1 1.0-4.1 1.3-4.6 1.3-4.6
Total Input Rated kW - - 0.780 0.780 1.030 1.030
Operating Current (Max) A - - 8.4 8.4 8.5 8.5
Input Rated kW 0.017 0.019 0.024 0.024 0.027 0.027
Operating Current(Max) A 0.17 0.19 0.2 0.2 0.3 0.3
Dimensions H*W*D mm 250-760-168 250-760-168 299-798-195 299-798-195 299-798-195 299-798-195
Weight kg 7.7 7.7 10 10 10 10
Indoor
Air Volume (SLo-Lo- Cooling m3/min 3.5 - 3.9 - 4.6 - 5.5 - 6.4 3.5 - 3.9 - 4.6 - 5.5 - 6.9 3.5 - 4.1 - 5.6 - 7.2 - 9.1 3.5 - 4.1 - 5.6 - 7.2 - 9.1 3.5 - 4.1 - 5.6 - 7.2 - 9.1 3.5 - 4.1 - 5.6 - 7.2 - 9.1
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 3.7 - 4.4 - 5.0 - 6.0 - 6.8 3.7 - 4.4 - 5.0 - 6.0 - 7.3 3.5 - 4.1 - 6.7 - 8.2 - 10.3 3.5 - 4.1 - 6.7 - 8.2 - 10.3 3.5 - 4.1 - 6.7 - 8.3 - 11.0 3.5 - 4.1 - 6.7 - 8.3 - 11.0
Sound Level (SPL) Cooling dB(A) 21 - 26 - 30 - 35 - 40 21 - 26 - 30 - 35 - 42 21 - 24 - 30 - 36 - 42 21 - 24 - 30 - 36 - 42 21 - 24 - 30 - 36 - 42 21 - 24 - 30 - 36 - 42
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 21 - 26 - 30 - 35 - 40 21 - 26 - 30 - 35 - 42 21 - 24 - 34 - 39 - 45 21 - 24 - 34 - 39 - 45 21 - 24 - 34 - 40 - 46 21 - 24 - 34 - 40 - 46
Sound Level (PWL) Cooling dB(A) - - 57 57 57 57
Dimensions H*W*D mm - - 550-800-285 550-800-285 550-800-285 550-800-285
Weight kg - - 31 31 31 31
Cooling m3/min - - 31.1 31.1 35.9 35.9
Air Volume
Heating m3/min - - 30.7 30.7 35.9 35.9
Outdoor
Cooling dB(A) - - 47 47 49 49
Unit Sound Level (SPL)
Heating dB(A) - - 48 48 50 50
Sound Level (PWL) Cooling dB(A) - - 58 58 62 62
Operating Current (Max) A - - 8.2 8.2 8.2 8.2
Breaker Size A - - 10 10 10 10
Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 9.52 6.35 / 9.52
Ext.
Max.Length Out-In m - - 20 20 20 20
Piping
Max.Height Out-In m - - 12 12 12 12
Guaranteed Operating Cooling ˚C - - -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46
Range (Outdoor) Heating ˚C - - -15 ~ +24 -20 ~ +24 -15 ~ +24 -20 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifications.
39

P029-048.indd 39 13.12.12 1:18:49 PM


MSZ-S SERIES SEER SCOP
A++ A+
MSZ-G SERIES
Please fill out the requested information
Please fill out the requested information

Indoor Unit Outdoor Unit Remote Controller

MSZ-SF25/35/42/50VE MUZ-SF25/35/42VE(H)

MSZ-GF60/71VE MUZ-SF50VE(H)
MUZ-GF60/71VE

Electrostatic Nano
Anti-allergy Platinum
Optional Optional

Wi-Fi
Interface
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MSZ-SF42VE MSZ-SF42VE MSZ-SF50VE MSZ-SF50VE MSZ-GF60VE MSZ-GF71VE
Outdoor Unit MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH MUZ-GF60VE MUZ-GF71VE
Refrigerant R410A(*1)
Power Source Outdoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230/Single/50
Design load kW 4.2 4.2 5 5 6.1 7.1
Annual electricity consumption (*2) kWh/a 196 196 246 246 311 364
SEER (*4) 7.5 7.5 7.2 7.2 6.8 6.8
Cooling Energy efficiency class A++ A++ A++ A++ A++ A++
Rated kW 4.2 4.2 5 5 6.1 7.1
Capacity
Min-Max kW 0.8-4.5 0.8-4.5 1.4-5.4 1.4-5.4 1.4-7.5 2.0-8.7
Total Input Rated kW 1.340 1.340 1.660 1.660 1.790 2.130
Design load kW 3.8(-10ºC) 3.8(-10ºC) 4.2(-10ºC) 4.2(-10ºC) 4.6(-10ºC) 6.7(-10ºC)
at reference design temperature kW 3.8(-10ºC) 3.8(-10ºC) 4.2(-10ºC) 4.2(-10ºC) 4.6(-10ºC) 6.7(-10ºC)
Declared
at bivalent temperature kW 3.8(-10ºC) 3.8(-10ºC) 4.2(-10ºC) 4.2(-10ºC) 4.6(-10ºC) 6.7(-10ºC)
Capacity
at operation limit temperature kW 3.4(-15ºC) 2.2(-20ºC) 3.4(-15ºC) 2.3(-20ºC) 3.7(-15ºC) 5.4(-15ºC)
Heating Back up heating capacity kW 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC)
(Average Annual electricity consumption (*2) kWh/a 1215 1242 1351 1380 1489 2204
Season)(*5) SCOP (*4) 4.4 4.3 4.4 4.3 4.3 4.2
Energy efficiency class A+ A+ A+ A+ A+ A+
Rated kW 5.4 5.4 5.8 5.8 6.8 8.1
Capacity
Min-Max kW 1.3-6.0 1.3-6.0 1.4-7.3 1.4-7.3 2.0-9.3 2.2-9.9
Total Input Rated kW 1.580 1.58 1.7 1.7 1.81 2.23
Operating Current (Max) A 9.5 9.5 12.3 12.3 14.5 16.6
Input Rated kW 0.027 0.027 0.035 0.035 0.062 0.058
Operating Current(Max) A 0.3 0.3 0.3 0.3 0.5 0.5
Dimensions H*W*D mm 299-798-195 299-798-195 299-798-195 299-798-195 325-1100-238 325-1100-238
Weight kg 10 10 10 10 16 16
Indoor
Air Volume (SLo-Lo- Cooling m3/min 5.0 - 5.8 - 6.7 - 7.9 - 9.1 5.0 - 5.8 - 6.7 - 7.9 - 9.1 5.6 - 6.2 - 7.0 - 8.2 - 9.9 5.6 - 6.2 - 7.0 - 8.2 - 9.9 9.8-11.3-13.4-15.6-18.3 9.7-11.5-13.3-15.4-17.8
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 5.0 - 5.8 - 7.2 - 9.1 - 11.4 5.0 - 5.8 - 7.2 - 9.1 - 11.4 5.6 - 6.4 - 8.0 - 9.8 - 12.0 5.6 - 6.4 - 8.0 - 9.8 - 12.0 9.8-11.3-13.4-15.6-18.3 10.2-11.5-13.3-15.4-17.8
Sound Level (SPL) Cooling dB(A) 28 - 31 - 34 - 38 - 42 28 - 31 - 34 - 38 - 42 30 - 33 - 36 - 40 - 45 30 - 33 - 36 - 40 - 45 29 - 37 -41 - 45 - 49 30 - 37 - 41 - 45 - 49
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 28 - 31 - 36 - 42 - 47 28 - 31 - 36 - 42 - 47 30 - 33 - 38 - 43 - 49 30 - 33 - 38 - 43 - 49 29 - 37 - 41 - 45 - 49 30 - 37 - 41 - 45 - 49
Sound Level (PWL) Cooling dB(A) 57 57 58 58 65 65
Dimensions H*W*D mm 550-800-285 550-800-285 880-840-330 880-840-330 880-840-330 880-840-330
Weight kg 35 35 55 55 50 53
Cooling m3/min 35.2 35.2 44.6 44.6 49.2 50.1
Air Volume
Heating m3/min 33.6 33.6 44.6 44.6 49.2 48.2
Outdoor
Cooling dB(A) 50 50 52 52 55 55
Unit Sound Level (SPL)
Heating dB(A) 51 51 52 52 55 55
Sound Level (PWL) Cooling dB(A) 63 63 65 65 65 65
Operating Current (Max) A 9.2 9.2 12 12 14 16.1
Breaker Size A 10 10 16 16 20 20
Diameter Liquid/Gas mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 12.7 6.35/15.88 9.52/15.88
Ext.
Max.Length Out-In m 20 20 30 30 30 30
Piping
Max.Height Out-In m 12 12 15 15 15 15
Guaranteed Operating Cooling ˚C -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46
Range (Outdoor) Heating ˚C -15 ~ +24 -20 ~ +24 -15 ~ +24 -20 ~ +24 -15 ~ +24 -15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifications.
40

P029-048.indd 40 13.12.12 1:18:50 PM


MSZ-HJ25 / 35 /50VA

MSZ-H SERIES
Compact, high-performance indoor and outdoor units and advanced inverter
technologies provide superior energy savings and comfort in all rooms.

Stylish Design with Flat Panel Front


A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room
aesthetics.

Advanced Inverter Control – 25·35

SEER
25·35

SCOP SEER
50 50

SCOP
Efficient Operation All the Time A A A+ A+

Mitsubishi Electric’s cutting-edge inverter technologies are adopted to provide automatic adjustment of operation load according to need. This
reduces excessive consumption of electricity, and thereby realises an Energy Rank “A” rating for 25·35 classes and “A+” for 50 classes.

Silent Operation
Quiet, relaxing space is within reach. Operational noise is a low 22dB ● Noise Level
(25-35 classes). Operation is so silent you might even forget the air
Quiet passenger Human
conditioner is on. Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet)

80dB 60dB 40dB 10dB


Only
*
22dB
*MSZ-HJ25/35VA

Long Piping Length Operating Range


Compared to previous models, the piping length is significantly As a result of an extended operating range when cooling, these
increased, further enhancing the ease and flexibility of installation. models accommodate a wider range of usage environments and
applications than previous models.
MSZ-HJ MSZ-HC
● Operating Range (Cooling)
Max piping length 20m 10m
Max piping height 12m 5m MUZ-HC +18°C +43°C

MUZ-HJ +15°C +46°C

Compact Units
The widths of both indoor and outdoor units are compact, making Indoor Unit: MSZ-HJ25/35/50VA Outdoor Unit: MUZ-HJ25/35VA
installation in small, tight spaces possible.

Only 799mm wide


m wide
Only 699m

41

P029-048.indd 41 13.12.12 1:18:51 PM


50 50 50
SEER SCOP
MSZ-H SERIES Please fill out the requested information
Please fill out the requested information
A +
A+

Indoor Unit Outdoor Unit Remote Controller

MUZ-HJ25/35VA
MSZ-HJ25/35/50VA

MUZ-HJ50VA

Type Inverter Heat Pump


Indoor Unit MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA
Outdoor Unit MUZ-HJ25VA MUZ-HJ35VA MUZ-HJ50VA
Refrigerant R410A(*1)
Power Source Indoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230V/Single/50Hz
Design load kW 2.5 3.1 5.0
Annual electricity consumption (*2) kWh/a 171 212 292
SEER (*4) 5.1 5.1 6.0
Cooling Energy efficiency class A A A+
Rated kW 2.5 3.15 5.0
Capacity
Min-Max kW 1.3 - 3.0 1.4 - 3.5 1.3 - 5.0
Total Input Rated kW 0.730 1.040 2.050
Design load kW 1.9(-10ºC) 2.4(-10ºC) 3.8(-10ºC)
at reference design temperature kW 1.9(-10ºC) 2.4(-10ºC) 3.8(-10ºC)
Declared
at bivalent temperature kW 1.9(-10ºC) 2.4(-10ºC) 3.8(-10ºC)
Capacity
at operation limit temperature kW 1.9(-10ºC) 2.4(-10ºC) 3.8(-10ºC)
Heating Back up heating capacity kW 0.0(-10ºC) 0.0(-10ºC) 0.0(-10ºC)
(Average Annual electricity consumption (*2) kWh/a 698 885 1267
Season)(*5) SCOP (*4) 3.8 3.8 4.2
Energy efficiency class A A A+
Rated kW 3.15 3.6 5.4
Capacity
Min-Max kW 0.9 - 3.5 1.1 - 4.1 1.4 - 6.5
Total Input Rated kW 0.870 0.995 1.480
Operating Current (Max) A 5.8 6.5 9.8
Input Rated kW 0.020 0.021 0.037
Operating Current(Max) A 0.3 0.3 0.4
Dimensions H*W*D mm 290-799-232 290-799-232 290-799-232
Weight kg 9 9 9
Indoor
Air Volume (SLo-Lo- Cooling m3/min 3.8 - 5.5 - 7.3 - 9.5 3.8 - 5.7 - 7.8 - 10.9 6.3 - 9.1 - 11.1 - 12.9
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 3.5 - 5.5 - 7.5 - 10.0 3.5 - 5.5 - 7.5 - 10.3 6.1 - 8.3 - 11.1 - 14.3
Sound Level (SPL) Cooling dB(A) 22 - 30 - 37 - 43 22 - 31 - 38 - 45 28 - 36 - 40 - 45
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 23 - 30 - 37 - 43 23 - 30 - 37 - 44 27 - 34 - 41 - 47
Sound Level (PWL) Cooling dB(A) 57 60 60
Dimensions H*W*D mm 538-699-249 538-699-249 550-800-285
Weight kg 24 25 36
Cooling m3/min 31.5 31.5 36.3
Air Volume
Heating m3/min 31.5 31.5 34.8
Outdoor
Cooling dB(A) 50 50 50
Unit Sound Level (SPL)
Heating dB(A) 50 50 51
Sound Level (PWL) Cooling dB(A) 63 64 64
Operating Current (Max) A 5.5 6.2 9.4
Breaker Size A 10 10 12
Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7
Ext.
Max.Length Out-In m 20 20 20
Piping
Max.Height Out-In m 12 12 12
Guaranteed Operating Cooling ˚C +15 ~ +46 +15 ~ +46 +15 ~ +46
Range (Outdoor) Heating ˚C -10 ~ +24 -10 ~ +24 -10 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifications.
42

P029-048.indd 42 13.12.12 1:18:52 PM


MFZ-KJ25/35/50VE

MFZ SERIES
High Capacity, Energy Savings and a Design in Harmony with Living Spaces
Raise the Value of Your Room to the Next Level.

Simple , Flat Design


Uneven surfaces have been smoothed to provide a simple design with linear beauty, harmonised with all types of interiors.

Images of installed unit


Unique configuration Two-block structure to
realising a flat, stylish look accommodate various Standard
installation patterns

Simple, symmetrical design


600 mm

Ingenious structure realizing


low-profile air inlet Semi-inbuilt

Base can be removed to


accentuate the stylish
Removable base section
750 mm 145
14 main body
mm
m
215
mm

Multi-flow Vane
Three uniquely shaped vanes control the airflow and allow the freedom to customize comfort according to preferences.

When heating When cooling

Air currents can be


controlled freely
Rapid heating
Warm air is blown
out in a downward
direction and then
sucked back into
the unit to quickly
raise the tempera-
ture of the air
being blown out.

* The downward airflow is also possible as well as heating.

25

SEER SCOP
Excellent Energy-saving Performance A+++ A+ Weekly Timer
(Introduced in response to market demand)
SEER A+++ (25) and SCOP A+ (25/35/50) ratings have been achieved
through development focusing on compliance with European ener- Temperature settings and On/Off control can be managed over a
gy-related product (ErP) regulations. period of one week using the Weekly Timer. Up to eight setting pat-
terns per calendar day are possible.
Cooling Heating
SEER
8.5 SEER
8.1
SEER
Trouble-free Installation and Maintenance
6.5
SCOP SCOP SCOP Using the original installation plate that comes as standard equip-
4.5 4.4 4.3 SEER Rank A(5.1) ment, installation of the unit is a snap. Levelling adjusters are pro-
vided, preventing damage to the wall. Generous pipe length (20–30
SCOP Rank A(3.4)
metres) is provided, so there is no need to worry about distance to
the outdoor unit. All units are equipped with an automatic self-diag-
nostics function as well. Simply access the trouble log recall mode
MFZ-KJ25VE MFZ-KJ35VE MFZ-KJ50VE for instant troubleshooting.

43

P029-048.indd 43 13.12.12 1:18:53 PM


25

SEER SCOP
MFZ-KJ SERIES Please fill out the requested information
Please fill out the requested information A+++
A+

Indoor Unit Outdoor Unit Remote Controller

MUFZ-KJ25/35VE

MFZ-KJ25/35/50VE

MUFZ-KJ50VE

Nano
Platinum
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MFZ-KJ25VE MFZ-KJ35VE MFZ-KJ50VE
Outdoor Unit MUFZ-KJ25VE MUFZ-KJ35VE MUFZ-KJ50VE
Refrigerant R410A(*1) R410A(*1) R410A(*1)
Power Source Outdoor power supply
Supply Outdoor(V/Phase/Hz) 230 / Single / 50
Design load kW 2.5 3.5 5.0
Annual electricity consumption (*2) kWh/a 102 150 266
SEER (*4) 8.5 8.1 6.5
Cooling Energy efficiency class A+++ A++ A++
Capacity Rated kW 2.5 3.5 5.0
Min-Max kW 0.5 - 3.4 0.5 - 3.7 1.6 - 5.7
Total Input Rated kW 0.540 0.940 1.410
o o o
Design load kW 3.4(-10 C) 3.5(-10 C) 4.4(-10 C)
o o o
Declared Capacity at reference design temperature kW 3.4(-10 C) 3.5(-10 C) 4.4(-10 C)
o o o
at bivalent temperature kW 3.4(-10 C) 3.5(-10 C) 4.4(-10 C)
o o o
at operation limit temperature kW 2.4(-15 C) 2.9(-15 C) 6.0(-15 C)
o o o
Heating Back up heating capacity kW 0.0(-10 C) 0.0(-10 C) 0.0(-10 C)
(Average Annual electricity consumption (*2) kWh/a 1059 1110 1406
Season) SCOP (*4) 4.5 4.4 4.3
Energy efficiency class A+ A+ A+
Capacity Rated kW 3.4 4.3 6.0
Min-Max kW 1.2 - 4.6 1.2 - 5.5 2.2 - 8.2
Total Input Rated kW 0.770 1.100 1.610
Operating Current (Max) A 9.4 9.4 14.0
Input Rated kW 0.016 0.016 0.038
Operating Current(Max) A 0.17 0.17 0.34
Dimensions H*W*D mm 600-750-215 600-750-215 600-750-215
Weight kg 15 15 15
Indoor
Unit Air Volume Cooling m3/min 3.9 - 4.9 - 5.9 - 7.1 - 8.2 3.9 - 4.9 - 5.9 - 7.1 - 8.2 5.6 - 6.7 - 8.0 - 9.3 - 10.6
(SLo-Lo-Mid-Hi-SHi (*3)) Heating m3/min 3.9 - 5.1 - 6.2 - 7.7 - 9.7 3.9 - 5.1 - 6.2 - 7.7 - 9.7 6.0 - 7.4 - 9.4 - 11.6 - 14.0
Sound Level (SPL) Cooling dB(A) 20 - 25 - 30 - 35 - 39 20 - 25 - 30 - 35 - 39 27 - 31 - 35 - 39 - 44
(SLo-Lo-Mid-Hi-SHi (*3)) Heating dB(A) 19 - 25 - 30 - 35 - 41 19 - 25 - 30 - 35 - 41 29 - 35 - 40 - 45 - 50
Sound Level (PWL) Cooling dB(A) 49 50 56
Dimensions H*W*D mm 550-800-285 550-800-285 880-840-330
Weight kg 37 37 55
Air Volume Cooling m3/min 31.3 31.3 45.8
Heating m3/min 33.6 33.6 45.8
Outdoor
Unit Sound Level (SPL) Cooling dB(A) 46 47 49
Heating dB(A) 51 51 51
Sound Level (PWL) Cooling dB(A) 59 60 63
Operating Current(Max) A 9.2 9.2 13.6
Breaker Size A 10 10 16
Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7
Ext.
Max.Length Out-In m 20 20 30
Piping
Max.Height Out-In m 12 12 15
o
Guaranteed Operating Range Cooling C -10 ~ +46 -10 ~ +46 -10 ~ +46
o
[Outdoor] Heating C -15 ~ +24 -15 ~ +24 -15 ~ +24

(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.

44

P029-048.indd 44 13.12.12 1:18:55 PM


MLZ-KA25/35/50VA

MLZ SERIES
Introducing a new type of ceiling cassette for the Multi-Split Series with streamed
interior dimensions and a sharp, sleek appearance.

Ceiling Mounted Access door not required Slim Body


Installing the ceiling-mounted MLZ The new units are designed with a slim body (only 175mm high), en-
Series unit in a room creates a more suring easy installation even when low ceiling cavities limit installa-
spacious feel that enhances room tion space. The need for ceiling cavity service space is also elimi-
comfort. This overhead format is also nated, further reducing the dimensions required for installation.
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as 175mm
book shelves are mounted on wall
surfaces.

Set Airflow According to Ceiling Height Auto Vane Control


Dual-level airflow selection is engineered to accommodate specific Outlet vanes can be moved left
ceiling heights. This is a key feature for adjusting airflow effectively and right, and up and down
when it is either too strong or too weak due to being mismatched using the remote controller. This
with the height of the ceiling. improved airflow control feature
solves the problem of drafts.

25 35 50
Standard 2.4m 2.4m 2.4m Left and Right
High ceiling 2.7m 2.7m 2.7m
Up and Down

Easy Installation
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.

● Drain Piping Supporters Installation Example


Easy joint
connections! Flexible drain joints
Built-in drain pump
Refrigerant pipe
secures drainage
water lift of 500mm Insulating material wrapping
only required from this point

Insulation material pretreatment


eliminates need for wrapping.
Flexible drain joints simplify
drain piping work in narrow ceiling areas
The newly adopted insulation-free cover eliminates
the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Drain cover

● Easy Mounting Plate


Suspension work simplified with
well-designed mounting plates
Secure one side Push the unit to the other side Move unit to the centre
Secure the opposite side

45

P029-048.indd 45 13.12.12 1:18:57 PM


MLZ-KA SERIES

Indoor Unit Outdoor Unit Remote Controller

For MXZ Connection Only

MLZ-KA25/35/50VA

Panel

MLP-440W

Optional Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA
Outdoor Unit for MXZ connection
Refrigerant R410A(*1)
Power Source Outdoor Power supply
Supply Outdoor ( V / Phase / Hz ) 230V / Single / 50Hz
Design load kW - - -
Annual electricity consumption (*2) kWh/a - - -
SEER (*4) - - -
Cooling Energy efficiency class - - -
Rated kW - - -
Capacity
Min-Max kW - - -
Total Input Rated kW - - -
Design load kW - - -
at reference design temperature kW - - -
Declared
at bivalent temperature kW - - -
Capacity
at operation limit temperature kW - - -
Heating Back up heating capacity kW - - -
(Average Annual electricity consumption (*2) kWh/a - - -
Season) SCOP (*4) - - -
Energy efficiency class - - -
Rated kW - - -
Capacity
Min-Max kW - - -
Total Input Rated kW - - -
Operating Current (Max) A 0.4 0.4 0.4
Input Rated kW 0.040 0.040 0.040
Operating Current(Max) A - - -
Dimensions H*W*D mm 175-1102-360 175-1102-360 175-1102-360
Weight kg 15 15 15
Indoor
Air Volume (SLo-Lo- Cooling m3/min 7.2-8.0-8.8 7.3-8.4-9.4 8.3-9.8-11.4
Unit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating m3/min 7.0-8.2-9.2 7.7-8.8-9.9 8.8-10.3-11.8
Sound Level (SPL) Cooling dB(A) 29-32-35 31-34-37 34-38-43
(SLo-Lo-Mid-Hi-SHi(*3)) Heating dB(A) 28-32-36 31-35-38 34-39-43
Sound Level (PWL) Cooling dB(A) - - -
Dimensions H*W*D mm 34-1200-414 34-1200-414 34-1200-414
Panel
Weight kg 3.5 3.5 3.5
Dimensions H*W*D mm - - -
Weight kg - - -
Cooling m3/min - - -
Air Volume 3
Heating m /min - - -
Outdoor
Cooling dB(A) - - -
Unit Sound Level (SPL)
Heating dB(A) - - -
Sound Level (PWL) Cooling dB(A) - - -
Operating Current (Max) A - - -
Breaker Size A - - -
Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7
Ext.
Max.Length Out-In m - - -
Piping
Max.Height Out-In m - - -
Guaranteed Operating Cooling ˚C - - -
Range (Outdoor) Heating ˚C - - -
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.

46

P029-048.indd 46 13.12.12 1:18:58 PM


Specification on Warmer Condition

Type Inverter Heat Pump


Indoor Unit MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE
Outdoor Unit MUZ-FH25VE MUZ-FH25VEHZ MUZ-FH35VE MUZ-FH35VEHZ MUZ-FH50VE MUZ-FH50VEHZ
Refrigerant R410A (*1)
Design load kW 2.5 2.5 3.5 3.5 5.0 5.0
(*2)
Cooling Annual electricity consumption kWh/a 96 96 138 138 244 244
SEER 9.1 9.1 8.9 8.9 7.2 7.2
Energy efficiency class A +++ A +++ A+++ A+++ A++ A++
Design load kW 1.7 (2°C) 1.8 (2°C) 2.0 (2°C) 2.2 (2°C) 2.5 (2°C) 3.3 (2°C)
at reference design temperature kW 1.7 (2°C) 1.8 (2°C) 2.0 (2°C) 2.2 (2°C) 2.5 (2°C) 3.3 (2°C)
Declared
at bivalent temperature kW 1.7 (2°C) 1.8 (2°C) 2.0 (2°C) 2.2 (2°C) 2.5 (2°C) 3.3 (2°C)
Heating Capacity at operation limit temperature kW 2.5 (-15°C) 1.7 (-25°C) 3.2 (-15°C) 2.6 (-25°C) 5.2 (-15°C) 3.8 (-25°C)
(Warmer
Season) Back up heating capacity kW 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C)
Annual electricity consumption (*2) kWh/a 376 397 429 471 614 787
SCOP 6.3 6.3 6.5 4.8 / 6.5 5.7 5.9
Energy efficiency class A+++ A+++ A +++ A+++ A+++ A+++

Type Inverter Heat Pump


Indoor Unit MSZ-EF25VE2 MSZ-EF35VE2 MSZ-EF42VE2 MSZ-EF50VE2
Outdoor Unit MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE
Refrigerant R410A (*1)
Design load kW 2.5 2.5 3.5 3.5 4.2 5.0
(*2)
Cooling Annual electricity consumption kWh/a 103 103 144 144 192 244
SEER 8.5 8.5 8.5 8.5 7.7 7.2
Energy efficiency class A+++ A+++ A+++ A+++ A++ A++
Design load kW 1.3 (2°C) 1.3 (2°C) 1.6 (2°C) 1.6 (2°C) 2.1 (2°C) 2.3 (2°C)
at reference design temperature kW 1.3 (2°C) 1.3 (2°C) 1.6 (2°C) 1.6 (2°C) 2.1 (2°C) 2.3 (2°C)
Declared
at bivalent temperature kW 1.3 (2°C) 1.3 (2°C) 1.6 (2°C) 1.6 (2°C) 2.1 (2°C) 2.3 (2°C)
Heating Capacity at operation limit temperature kW 2.0 (-15°C) 1.6 (-20°C) 2.4 (-15°C) 1.7 (-20°C) 3.4 (-15°C) 3.5 (-15°C)
(Warmer
Season) Back up heating capacity kW 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C)
Annual electricity consumption (*2) kWh/a 304 304 396 396 491 557
SCOP 6.0 6.0 5.7 5.7 6.0 5.8
Energy efficiency class A+++ A+++ A+++ A+++ A+++ A+++

Type Inverter Heat Pump


Indoor Unit MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE
Outdoor Unit MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH
Refrigerant R410A (*1)
Design load kW 2.5 2.5 3.5 3.5 4.2 4.2 5.0 5.0
(*2)
Cooling Annual electricity consumption kWh/a 116 116 171 171 196 196 246 246
SEER 7.6 7.6 7.2 7.2 7.5 7.5 7.2 7.2
Energy efficiency class A++ A++ A++ A++ A++ A++ A++ A++
Design load kW 1.3 (2°C) 1.3 (2°C) 1.6 (2°C) 1.6 (2°C) 2.1 (2°C) 2.1 (2°C) 2.3 (2°C) 2.3 (2°C)
at reference design temperature kW 1.3 (2°C) 1.3 (2°C) 1.6 (2°C) 1.6 (2°C) 2.1 (2°C) 2.1 (2°C) 2.3 (2°C) 2.3 (2°C)
Declared
at bivalent temperature kW 1.3 (2°C) 1.3 (2°C) 1.6 (2°C) 1.6 (2°C) 2.1 (2°C) 2.1 (2°C) 2.3 (2°C) 2.3 (2°C)
Heating Capacity at operation limit temperature kW 2.0 (-15°C) 1.6 (-20°C) 2.2 (-15°C) 1.6 (-20°C) 3.4 (-15°C) 2.2 (-20°C) 3.4 (-15°C) 2.3 (-20°C)
(Warmer
Season) Back up heating capacity kW 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C) 0.0 (2°C)
(*2)
Annual electricity consumption kWh/a 337 337 923 / 418 417 507 507 563 563
SCOP 5.4 5.4 5.4 5.4 5.8 5.8 5.7 5.7
Energy efficiency class A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++

Type Inverter Heat Pump


Indoor Unit MSZ-GF60VE MSZ-GF71VE
Outdoor Unit MUZ-GF60VE MUZ-GF71VE
Refrigerant R410A (*1)
Design load kW 6.1 7.1
(*2)
Cooling Annual electricity consumption kWh/a 311 364
SEER 6.8 6.8
Energy efficiency class A++ A++
Design load kW 2.5 (2°C) 3.7 (2°C)
At reference design temperature kW 2.5 (2°C) 3.7 (2°C)
Declared
at bivalent temperature kW 2.5 (2°C) 3.7 (2°C)
Heating Capacity at operation limit temperature kW 3.7 (-15°C) 5.4 (-15°C)
(Warmer
Season) Back up heating capacity kW 0.0 (2°C) 0.0 (2°C)
(*2)
Annual electricity consumption kWh/a 664 963
(*4)
SCOP 5.3 5.4
Energy efficiency class A+++ A+++

Type Inverter Heat Pump


Indoor Unit MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA
Outdoor Unit MUZ-HJ25VA MUZ-HJ35VA MUZ-HJ50VA
Refrigerant R410A (*1)
Design load kW 2.5 3.1 5.0
(*2)
Cooling Annual electricity consumption kWh/a 171 212 292
SEER 5.1 5.1 6.0
Energy efficiency class A A A+
Design load kW 1.1 (2°C) 1.3 (2°C) 2.1 (2°C)
at reference design temperature kW 1.1 (2°C) 1.3 (2°C) 2.1 (2°C)
Declared
at bivalent temperature kW 1.1 (2°C) 1.3 (2°C) 2.1 (2°C)
Heating Capacity at operation limit temperature kW 1.9 (-10°C) 2.4 (-10°C) 3.8 (-10°C)
(Warmer
Season) Back up heating capacity kW 0.0 (2°C) 0.0 (2°C) 0.0 (2°C)
(*2)
Annual electricity consumption kWh/a 356 426 539
SCOP 4.3 4.3 5.5
Energy efficiency class A+ A+ A+++

(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

47

P029-048.indd 47 13.12.12 1:18:59 PM


48

P029-048.indd 48 13.12.12 1:18:59 PM


SERIES

49

P049-080.indd 49 13.12.12 1:19:37 PM


SELECTION
Series line-up consists of two types of indoor units.
Choose the model that best matches room conditions.

STEP 1 SELECT INDOOR UNIT


Select the optimal unit and capacity required to match room construction and air conditioning requirements.

Units without Remote Controller Units without Remote Controller


SLZ-KA25VAQ2 SEZ-KD25VAQ
SLZ-KA35VAQ SEZ-KD35VAQ
SLZ-KA50VAQ SEZ-KD50VAQ
SEZ-KD60VAQ
*Requires SLP-2AAW grille.
*Requires PAR-31MAA or PAC-YT52CRA remote controller. SEZ-KD71VAQ
*Requires PAR-31MAA or PAC-YT52CRA remote controller.

Units with Wireless Remote Controller Units with Wireless Remote Controller
SLZ-KA25VAL2 SEZ-KD25VAL
SLZ-KA35VAL SEZ-KD35VAL
SLZ-KA50VAL SEZ-KD50VAL
*Requires SLP-2ALW grille. SEZ-KD60VAL
SEZ-KD71VAL

STEP 2 SELECT OUTDOOR UNIT


There is one outdoor unit for respective indoor units.

SUZ-KA25/35VA4 SUZ-KA50/60/71VA4

✽ To confirm compatibility with the MXZ Series multi-type system, refer to the MXZ Series page.

50

P049-080.indd 50 13.12.12 1:19:37 PM


SLZ SERIES
SLZ-KA25VAQ2/VAL2
SLZ-KA35-50VAQ/VAL

Compact, lightweight ceiling cassette units with 4-way air outlets provide
maximum comfort by evenly distributing airflow throughout the entire room.

Compact Panel Size


The attractive SLZ Series ceiling cassette units offer a slim 570mm width and a 4-way air outlet. The size and shape are a perfect match for ceilings
made using 2’x2’ construction, and the light 16.5kg package makes installation easy.

● SLZ-KA35VAQ
The compact body matches 2’x2’ (600mm x 600mm)
ceiling construction specifications.
Reduced
270mm
420

570
compared to
PLA-RP35BA
570mm 570mm
Suspension LEG Bolt to bolt
530

Suspension bolt

Reduced
23mm
208

T-bar
235 compared to
Unit PLA-RP35BA
Ceiling panel
570
576
600 (unit: mm)

✽ Access door is required

Fresh-air Intake
A duct hole is provided in the main body, making it possible to intake ● Intake-air volume
fresh air from outside.
Static pressure: P [Pa]

50 Airflow: Q [m3/min]

Fresh-air intake 0.5 1.0 1.5 2.0 2.5 3.0 3.5


0
Detail drawing of fresh-air intake

–50
25
100 73.4
3- 2.8 hole Cut-out hole –100
Burring hole

–150
118
120

–200
12
°

Drain pipe

Electrical box –250

Refrigerant pipe Ceiling surface


–300

Note: Intake-air volume should be 20% or less of overall air volume


in order to prevent condensation.

51

P049-080.indd 51 13.12.12 1:19:38 PM


Heat Caulking
SLZ-KA SERIES Please fill out the requested information
Please fill out the requested information
Fixing Method

Indoor Unit Outdoor Unit Remote Controller

SUZ-KA25/35VA4
Enclosed in
SLZ-KA25/35/50VAL

SLZ-KA25VAQ2, SLZ-KA35/50VAQ (Requires Wired Remote Controller)


SLZ-KA25VAL2, SLZ-KA35/50VAL (Wireless Remote Controller is enclosed)

Panel
SLP-2AAW (for SLZ-KA VAQ) *optional *optional
SLP-2ALW (for SLZ-KA VAL) SUZ-KA50VA4 (for SLZ-KA VAQ) (for SLZ-KA VAQ)

VA VAQ

Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit SLZ-KA25VAQ2 SLZ-KA25VAL2 SLZ-KA35VAQ SLZ-KA35VAL SLZ-KA50VAQ SLZ-KA50VAL
Outdoor Unit SUZ-KA25VA4 SUZ-KA35VA4 SUZ-KA50VA4
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50
Cooling Capacity Rated kW 2.6 3.5 4.6
Min - Max kW 1.5 - 3.2 1.4 - 3.9 2.3 - 5.2
Total Input Rated kW 0.700 1.020 1.430
Design Load kW 2.6 3.5 4.6
2
Annual Electricity Consumption* kWh/a 190 240 316
SEER 4.8 5.1 5.1
Energy Efficiency Class B A A
Heating Capacity Rated kW 3.2 4.0 5.0
(Average Min - Max kW 1.3 - 4.5 1.7 - 5.0 1.7 - 6.5
Season)
Total Input Rated kW 0.850 1.090 1.550
Design Load kW 2.2 2.6 3.6
Declared Capacity at reference design temperature kW 2.0 (–10°C) 2.3 (–10°C) 3.2 (–10°C)
at bivalent temperature kW 2.0 (–7°C) 2.3 (–7°C) 3.2 (–7°C)
at operation limit temperature kW 2.0 (–10°C) 2.3 (–10°C) 3.2 (–10°C)
Back Up Heating Capacity kW 0.2 0.3 0.4
Annual Electricity Consumption*2 kWh/a 789 932 1325
SCOP 3.9 3.9 3.8
Energy Efficiency Class A A A
Operating Current (max) A 7.4 8.6 12.7
Indoor Input Rated kW 0.085 0.085 0.085
Unit Operating Current (max) A 0.4 0.4 0.7
Dimensions <Panel> H × W × D mm 235-570-570 <20-650-650> 235-570-570 <20-650-650> 235-570-570 <20-650-650>
Weight <Panel> kg 17 <3> 17 <3> 17 <3>
Air Volume [Lo-Mid-Hi] m3/min 8 - 9 - 11 8 - 9 - 11 8 - 9 - 11
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 29 - 33 - 38 29 - 33 - 38 30 - 34 - 39
Sound Level (PWL) dB(A) 57 57 58
Outdoor Dimensions H×W×D mm 550 - 800 - 285 550 - 800 - 285 880 - 840 - 330
Unit Weight kg 30 35 54
3
Air Volume Cooling m /min 32.6 36.3 44.6
3
Heating m /min 34.7 34.8 44.6
Sound Level (SPL) Cooling dB(A) 47 49 52
Heating dB(A) 48 50 52
Sound Level (PWL) Cooling dB(A) 58 62 65
Operating Current (max) A 7.0 8.2 12.0
Breaker Size A 10 10 20
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7
Piping Max. Length Out-In m 20 20 30
Max. Height Out-In m 12 12 30
o
Guaranteed Operating Range Cooling C –10 ~ +46 –10 ~ +46 –15 ~ +46
[Outdoor] Heating o
C –10 ~ +24 –10 ~ +24 –10 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

52

P049-080.indd 52 13.12.12 1:19:39 PM


SEZ SERIES SEZ-KD25 -71VAQ/VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this A Air inlet
ceiling-concealed indoor unit. The rest of the unit is conveniently B Air outlet
C Access door
hidden in the ceiling cavity, essentially leaving the ceiling and walls D Ceiling surface
free of bulky looking devices and maintaining a high-class interior E Canvas duct
décor. The compact units require minimal space and can be installed F Air filter
G Inlet grille
in buildings with lowered ceilings, where exposed units were the
rule in the past.

Width reduced by
Dimension Comparison
110mm
1100 700 990

Height
200 reduced by
270
70mm

SEZ-KA35VA SEZ-KD35VAQ

Increased Selection of Fan Speeds and


Static Pressure Levels We’ve lowered the minimum static pressure level, resulting
in less room noise when the optimum static pressure is
DC fan motor settings have been increased to accommodate more selected.
application needs. Three fan speed settings (Low, Medium and
High) and four static pressure levels (5, 15, 35 and 50Pa) are now
available.

External Static Pressure SPL (Low Fan Mode)

SEZ-KC25VA 5 Pa SEZ-KA SEZ-KD

SEZ-KA35-71VA 30/50 Pa External Static Pressure 30 Pa 15 Pa

35 30dB 23dB

50 31dB 30dB

SEZ-KD25-71VA 5/15/35/50 Pa 60 32dB 30dB

71 32dB 30dB
Four Levels Available for All Models
Maximum noise
reduced by 7dB

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
adding to increased installation possibilities.

53

P049-080.indd 53 13.12.12 1:19:40 PM


Heat Caulking
SEZ-KD SERIES Please fill out the requested information
Please fill out the requested information
Fixing Method

Indoor Unit Outdoor Unit Remote Controller

SUZ-KA25/35VA4
Enclosed in
SEZ-KD25/35/50/60/71VAQ (Requires Wired Remote Controller)
SEZ-KD25/35/50/60/71VAL
SEZ-KD25/35/50/60/71VAL (Wireless Remote Controller is enclosed)

*optional *optional
SUZ-KA50/60/71VA4 (for SEZ-KD VAQ) (for SEZ-KD VAQ)

VAQ

Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit SEZ-KD25VAQ/VAL SEZ-KD35VAQ/VAL SEZ-KD50VAQ/VAL SEZ-KD60VAQ/VAL SEZ-KD71VAQ/VAL
Outdoor Unit SUZ-KA25VA4 SUZ-KA35VA4 SUZ-KA50VA4 SUZ-KA60VA4 SUZ-KA71VA4
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50
Cooling Capacity Rated kW 2.5 3.5 5.1 5.6 7.1
Min - Max kW 1.5 - 3.2 1.4 - 3.9 2.3 - 5.6 2.3 - 6.3 2.8 - 8.3
Total Input Rated kW 0.730 1.010 1.580 1.740 2.210
Design Load kW 2.5 3.5 5.1 5.6 7.1
2
Annual Electricity Consumption* kWh/a 168 219 313 376 477
3
SEER* 5.2 5.6 5.7 5.2 5.2
Energy Efficiency Class A A+ A+ A A
Heating Capacity Rated kW 2.9 4.2 6.4 7.4 8.1
(Average Min - Max kW 1.3 - 4.5 1.7 - 5.0 1.7 - 7.2 2.5 - 8.0 2.6 - 10.4
Season)
Total Input Rated kW 0.803 1.130 1.800 2.200 2.268
Design Load kW 2.2 2.8 4.6 5.5 6.0
Declared Capacity at reference design temperature kW 1.9 (–10°C) 2.5 (–10°C) 4.1 (–10°C) 4.8 (–10°C) 5.3 (–10°C)
at bivalent temperature kW 1.9 (–7°C) 2.5 (–7°C) 4.1 (–7°C) 4.8 (–7°C) 5.3 (–7°C)
at operation limit temperature kW 1.9 (–10°C) 2.5 (–10°C) 4.1 (–10°C) 4.8 (–10°C) 5.3 (–10°C)
Back Up Heating Capacity kW 0.3 0.3 0.5 0.7 0.7
Annual Electricity Consumption*2 kWh/a 808 979 1653 1878 2202
SCOP*3 3.8 4.0 3.9 4.1 3.8
Energy Efficiency Class A A+ A A+ A
Operating Current (max) A 7.4 8.7 12.7 14.7 17.0
Indoor Input Rated kW 0.040 0.050 0.070 0.070 0.100
Unit Operating Current (max) A 0.4 0.5 0.7 0.7 0.9
Dimensions <Panel> H × W × D mm 200 - 790 - 700 200 - 990 - 700 200 - 990 - 700 200 - 1190 - 700 200 - 1190 - 700
Weight <Panel> kg 18 21 23 27 27
Air Volume [Lo-Mid-Hi] m3/min 6-7-9 7 - 9 - 11 10 - 13 - 15 12 - 15 - 18 12 - 16 - 20
External Static Pressure Pa 5 / 15 / 35 / 50 5 / 15 / 35 / 50 5 / 15 / 35 / 50 5 / 15 / 35 / 50 5 / 15 / 35 / 50
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 22 - 25 - 29 23 - 28 - 33 29 - 33 - 36 29 - 33 - 37 29 - 34 - 39
Sound Level (PWL) dB(A) 50 53 57 58 60
Outdoor Dimensions H×W×D mm 550 - 800 - 285 550 - 800 - 285 880 - 840 - 330 880 - 840 - 330 880 - 840 - 330
Unit Weight kg 30 35 54 50 53
3
Air Volume Cooling m /min 32.6 36.3 44.6 40.9 50.1
3
Heating m /min 34.7 34.8 44.6 49.2 48.2
Sound Level (SPL) Cooling dB(A) 47 49 52 55 55
Heating dB(A) 48 50 52 55 55
Sound Level (PWL) Cooling dB(A) 58 62 65 65 69
Operating Current (max) A 7.0 8.2 12.0 14.0 16.1
Breaker Size A 10 10 20 20 20
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 20 20 30 30 30
Max. Height Out-In m 12 12 30 30 30
o
Guaranteed Operating Range Cooling C –10 ~ +46 –10 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating o
C –10 ~ +24 –10 ~ +24 –10 ~ +24 –10 ~ +24 –10 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 SEER/SCOP are measured at ESP 35Pa.

54

P049-080.indd 54 13.12.12 1:19:41 PM


SERIES

55

P049-080.indd 55 13.12.12 1:19:41 PM


SELECTION
Line-up includes a selection of eight indoor units and four series of outdoor units.
Easily construct a system that best matches room air conditioning needs.

STEP 1 SELECT INDOOR UNIT


Select the optimum indoor unit and capacity based on room size and shape.

Wall-mounted
PKA-HAL
4-way ceiling-cassette
PLA-ZRP BA
PLA-RP BA Ceiling-suspended
PCA-KAQ
Wall-mounted
PKA-KAL

Ceiling-concealed Floor-standing Professional Kitchen Ceiling-concealed


PEAD-JA(L)Q PSA-KA PCA-HAQ PEA-GAQ

STEP 2 SELECT OUTDOOR UNIT


The best outdoor unit for the system depends on the combination of functions desired (e.g. energy savings, system capacity, long pipe length).
Check the specifications of the system you need, and then select the optimum outdoor unit series.

Power Inverter Standard Inverter

PUHZ-RP200/250 PUHZ-ZRP100/125/140 PUHZ-ZRP60/71 PUHZ-ZRP35/50 PUHZ-P125/140/200/250 PUHZ-P100 SUZ-KA50/60/71 ✽ SUZ-KA35 ✽

✽ Some indoor units cannot be used with this unit.

To confirm compatibility with the MXZ Series, refer to the MXZ Series page.

STEP 3 SELECT COMBINATION


Choose the installation pattern for the indoor units. (In the case of a multi-system, distribution piping is necessary, so please select the necessary piping as well.)

Single System Simultaneous Multi-System Quadruple Realises the optimum temperature


distribution even in a large space.
Twin Allows simultaneous operation of
two indoor units on one floor.

Triple Can cover a large-scale space or dispersed


installation on the same floor.

Connectable Combinations for Inverter Units (PUHZ-ZRP / PUHZ-RP / PUHZ-P)


Indoor Unit Capacity
Outdoor Unit Capacity Twin Triple Quadruple
50 : 50 33 : 33 : 33 25 : 25 : 25 : 25
71 35 × 2 — —
100 50 × 2 — —
125 60 × 2 — —
140 71 × 2 50 × 3 —
200 100 × 2 60 × 3 50 × 4
250 125 × 2 71 × 3 60 × 4
MSDD-50TR-E
Distribution Pipe MSDT-111R-E MSDF-1111R-E
MSDD-50WR-E

Notes: 1) Indoor unit combinations with floor-standing (PS) units and other types are impossible.
2) The distribution pipe listed is required for simultaneous multi-systems.

56

P049-080.indd 56 13.12.12 1:19:45 PM


Power Inverter
Our new Power Inverter Series is designed to achieve industry-leading seasonal
SERIES
energy-efficiency through use of new technologies and high-performance com-
pressor. Installation is now even easier thanks to outdoor units with a side-flow con-
figuration, a maximum piping length of 120m and pipe-replacement technologies.

Industry-leading Energy Efficiency in New Seasonal Ratings


Industry-leading energy efficiency has been achieved through optimisation of a newly designed compressor and use of the latest energy-saving tech-
nologies. The new Power Inverter Series, designed to realise outstanding seasonal energy-efficiency, achieves high energy-efficiency rankings of A+
or A++ for both cooling and heating in most categories. Annual power consumption has been drastically reduced to realise savings in operating cost.
Annual electricity consumption comparison (PLA-ZRP/PUHZ-ZRP vs PLA-RP/PUHZ-RP) Energy Rank (Cooling/Heating)
<Cooling>
Series 35 50 60 71 100
1000 PLA-ZRP/PUHZ-ZRP 20% 18%
saving 4-way ceiling cassette PLA-ZRP BA A++/A++ A++/A++ A++/A+ A++/A+ A++/A++
saving
[kWh/annum]

800 PLA-RP/PUHZ-RP 24%


saving PLA-RP BA A++/A+ A+/A+ A+/A A++/A+ A++/A+
600 21% 20%
23% saving saving Wall-mounted PKA-HAL/KAL A+/A A/A+ A++/A+ A++/A+ A++/A+
400
30% saving
saving Ceiling-suspended PCA-KAQ A++/A+ A+/A+ A++/A+ A++/A+ A+/A
200 PCA-HAQ – – – A+/A –
0 Floor-standing PSA-KA – – – A++/A+ A+/A+
35 50 6071 100 125 140 Ceiling-concealed PEAD-JAQ A+/A+ A+/A+ A++/A+ A+/A A+/A+
Rated Capacity
✽ Results are based on our own simulations. Actual power consumption ✽ The ErP Directive (Lot 10) applies to air conditioners of rated capacity up to 12kW.
may vary depending on how and where the units are used.

ADVANCED ENERGY-SAVING TECHNOLOGIES

Highly efficient fan and grille for outdoor unit


The shapes of the fan and grille of the outdoor unit were redesigned, realising an increase in blowing capacity and more efficient heat
exchange while maintaining the same operating noise level.
Outdoor unit fan opening increased <100–250> Grille shape changed <60–250> Inflexed fan <100–250>
The diameter of the opening for the fan in the outdoor unit has been The shape of the air outlet grille has been Adoption of a fan with improved ventila-
increased from 490 to 550mm. Blowing capacity has been in- changed to reduce pressure loss. This has tion characteristics and a newly designed
creased while maintaining the same fan rotation speed. helped improve heat exchange performance. rear edge that suppresses wind turbu-
lence raises fan operation efficiency.

Opening increased
from 490 to 550cm
in diameter
Fan rear edge

Highly efficient heat exchanger


A high density and increase in surface area have improved the heat-exchange efficiency of the heat exchanger.

High-density heat exchanger <100–250> Heat-exchange surface area increased <100–250>


The pipe diameter for the RP100–140 has been changed Heat exchanger size extended horizontally, increasing the surface area.
from 9.52 to 7.94mm, the same fine pipe diameter as
that used for RP200–250 units, resulting in a high-
Increase in heat-exchanger surface area
density heat exchanger.
2 lines, 52 columns

2 lines, 64 columns
(RP100–140) Heat exchanger Heat exchanger

Heat Interchanger (HIC) Added <140>


A HIC circuit has been added to improve energy efficiency during cooling opera-
Cooling operation Compressor
tion. Liquid refrigerant is rerouted, transformed into a gas state and injected back
into the system to increase overall pressure of the refrigerant being sent to the
compressor, thereby reducing the load on the compressor and raising efficiency.
Indoor Power Outdoor
HEX receiver HEX
A w/ HIC circuit
LEV A
w/o HIC circuit
LEV B Increasing the pressure of the
refrigerant sent to the compressor
Heat reduces the compression load
A interchanger
Heat Interchanger (HIC) (HIC) LEV C

57

P049-080.indd 57 13.12.12 1:19:48 PM


Side-flow Outdoor Units 3-phase Power-supply Inverter (100–250)
All operating capacities have been unified to the side-flow configu- Incorporation of a 3-phase power supply realises a dramatic reduc-
ration. Even for locations requiring large capacities, the small foot- tion in operating current. This special technology is equipped in out-
print of these outdoor units enable them to be used anywhere. door units to ensure compliance with electromagnetic compatibility
regulations in Europe.

Operating current comparison (for combinations using 4-way ceiling cassettes)


Power Supply PUHZ-ZRP100YKA PUHZ-ZRP125YKA PUHZ-ZRP140YKA
Rated (cooling) 4.2 6.2 7.0
Rated (heating) 4.2 5.9 7.5
3-phase
Max. 8.7 10.3 12.1
Breaker size 16 16 16
PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100/125/140
PUHZ-RP200/250 Power Supply PUHZ-ZRP100VKA PUHZ-ZRP125VKA PUHZ-ZRP140VKA
Rated (cooling) 11.9 17.6 19.9
Twin Rotary Compressor (PUHZ-ZRP35/50/60/71) Rated (heating) 11.9 16.6 21.3
1-phase
Powerful yet high-efficiency rotary compressors that make use of Max. 27.2 27.3 29.1
Mitsubishi Electric technologies to achieve industry-leading energy Breaker size 32 32 40
efficiency under the new seasonal ratings. Annual power consump-
tion has been significantly reduced compared to conventional
Long Pipe Length
units thanks to original Mitsubishi Electric technologies: “Poki-Poki
Motors”, “Heat Caulking Fixing Method, “Divisible Middle Plate” The additional refrigerant volume enables piping lengths of up to
and “Flat Induction Pipe.” 100m (RP200/250), thereby making installation more flexible.

DC Scroll Compressor (PUHZ-ZRP100/125/140) Model Max. Pipe Length Max. Height Difference
PUHZ-ZRP35/50 50m 30m
Our newly developed DC scroll compressor realises higher effi- PUHZ-ZRP60/71 50m 30m
ciency at partial load, which accounts for most of the operating PUHZ-ZRP100/125/140 75m 30m
time in both cooling and heating modes. The asymmetrically
PUHZ-RP200/250 100m (120m*) 30m
shaped scroll contributes to higher SEER and SCOP values and
When the total control/power cable length exceeds 80m, separate power sources are
greatly reduces the annual power consumption. Compression effi- required for the indoor and outdoor units. (An optional power-supply terminal kit is needed
ciency is also improved through optimised compression and reduc- for indoor units with no power-supply terminal block.)
tion of refrigerant pressure loss. * Total piping length can be extended up to 120m in the case of a multi-system.

Cleaning-free Pipe Reuse Technology


Ability to use existing piping reduces pipe waste and replacement time
No Need to Clean at the Time of System Renewal
Chloride residue builds up in existing pipes and becomes a source of trouble. In addition, the iron particles and slime produced as a result of
compressor failure lead to problems. To counter this, various original Mitsubishi Electric technologies have been combined to enable the intro-
duction of “cleaning-free pipe reuse.”

Why can’t existing piping be used?


R22 refrigerant R410A refrigerant

Problem Problem Result

At time of renewal Chloride residue


High heat generated during Accelerated deterioration
operation of refrigerant oil
Increased chloride residue
At time of
compressor failure Refrigerant circuit malfunc-
Iron particles and slime tions and causes failure

Cleaning pipe or replacement with new pipe is required

Mitsubishi Electric’s Original Replacement Technologies

Countermeasure for Problem 1 Countermeasure for Problem 2

Technology 1 Wide strainer Technology 2


Original High-quality Filtration Friction Reduction (moving parts in compressor)
Our original high-quality filtration device called the “wide strainer” Friction inside the compressor is reduced by using an
is equipped inside the refrigerant inlet and outlet pipe. The “wide original Mitsubishi Electric technology called the “Heat
strainer” traps iron particles and realises cleaning-free pipe reuse. Caulking Fixing Method” or coating the edge of the blade
In addition, improvements to the metal used in the bearings of in the scroll compressor, thereby suppressing the increase
our new scroll compressors realise more robust units. in temperature that causes refrigerant oil deterioration.

Existing piping can be used without cleaning

Cautions when using existing piping


• When removing an old air conditioning unit, please make sure to perform the pump-down process and recover the refrigerant and refrigerant oil.
• Check to ensure that the piping diameter and thickness match Mitsubishi Electric specifications.
• Check to ensure that the flare is compatible with R410A.

58

P049-080.indd 58 13.12.12 1:19:49 PM


PLA-ZRP35/50/60/71/100/125/140BA
PLA-RP35/50/60/71/100/125/140BA

PLA SERIES
A complete line-up including deluxe units that offer added energy savings. The incorpora-
tion of wide air-outlet and the “i-see Sensor” enhances airflow distribution control, achiev-
ing an enhanced level of comfort throughout the room. The synergy of higher energy
efficiency and more comfortable room environment results in the utmost user satisfaction.

Deluxe 4-way Cassette Line-up


For users seeking even further energy-savings, Mitsubishi Electric offers complete deluxe units (PLA-ZRP) for the complete line-up of models in
this series from 35–140. Compared to the standard models (PLA-RP), deluxe models provide additional energy-savings, contributing to a significant
reduction in electricity costs.
■ Line-up ■ Key Technologies for Higher Energy Efficiency
Model 35 50 60 71 100 125 140 New Heat Exchanger Design
Series
Heat exchanger fin size and pitch have been
Deluxe 4-way Cassette
changed, raising energy efficiency.
(PLA-ZRP) PLA-ZRP35BA PLA-ZRP50BA PLA-ZRP60BA PLA-ZRP71BA PLA-ZRP100BA PLA-ZRP125BA PLA-ZRP140BA
Pre-grooved Piping
Standard 4-way Cassette
(PLA-RP) High-performance pre-grooved piping is utilised,
PLA-RP35BA PLA-RP50BA PLA-RP60BA PLA-RP71BA PLA-RP100BA PLA-RP125BA PLA-RP140BA2 increasing the heat exchange area.

■ Indoor/Outdoor Unit Combinations


Deluxe 4-way Cassette Standard 4-way Cassette
PLA-ZRP BA PLA-RP BA

Power Inverter Standard Inverter Power Inverter Standard Inverter

PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100/125/140 PUHZ-P100 PUHZ-P125/140/200/250 PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100/125/140 SUZ-KA35 SUZ-KA50/60/71
PUHZ-RP200/250 PUHZ-RP200/250

“Rank A++/A+” Energy Savings Achieved for Deluxe 4-way Cassette


Our new deluxe 4-way cassette indoor units combined with newly designed Power Inverter outdoor units (PUHZ-ZRP) achieve industry-leading
seasonal efficiency for both cooling and heating: all rank A++ for cooling and A+ or higher for heating.
SEER SEER SEER SEER SEER
A++ SEER A++
A++ A++ A++ A++
SCOP SCOP SCOP SCOP SCOP SCOP
A++ A++ A+ A+ A++ A++
6.8 6.4 6.7 6.5 6.4
6.1 6.0 5.9 6.1 6.0
Minimum SEER 3.6
4.1 4.1 4.5 4.5
4.6 4.6 4.2 4.5 4.6 4.6
Minimum SCOP 3.4

Cooling PLA-ZRP35BA PLA-ZRP50BA PLA-ZRP60BA PLA-ZRP71BA PLA-ZRP100BA PLA-ZRP100BA PLA-ZRP125BA PLA-ZRP125BA PLA-ZRP140BA PLA-ZRP140BA
Heating PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA PUHZ-ZRP125VKA PUHZ-ZRP125YKA PUHZ-ZRP140VKA PUHZ-ZRP140YKA
✽ For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.

Great Reduction in Annual Electricity Automatic Grille Lowering


Power Consumption Function (PLP-6BAJ) Automatic
descent down
to 4m
Industry-leading energy efficiency has been achieved through newly designed An automatic grille lowering function is avail-
Power Inverter outdoor units combined with new highly efficient deluxe 4-way able for easy filter maintenance. Special
cassettes. Annual power consumption for cooling and heating are significantly wired and wireless remote controllers can
reduced. be used to lower the grille for maintenance. 1.2m

Cooling 14% save 12% save


The grille can be lowered a maximum of 4m from the 1.6m
700
16% save 23% save
[kWh/annum]

600 27% save Standard ceiling in 8 steps, thus enabling easy cleaning of the air
500 24% save 628 628 Deluxe
538 549 filter. Cleaning of the filter is an important factor for 2.0m
400 486
300 376 418 370 saving energy.
200 350
244 272 2.4m
100 185
0
35 50 60 71 100V 100Y 2.8m
Heating 18% save 18% save
3500
Grille Elevation Remote Controller 3.2m
30% save Standard
[kWh/annum]

3000 13% save (comes with the automatic elevation panel)


2500 26% save 2945 2945 Deluxe
2000 25% save 2410 2410 3.6m
1500 2117
1000 1581 1688 1462 1476
1162 4.0m
500 984 729
0 Wired
35 50 60 71 100V 100Y Remote
✽ Energy consumption based on standard test results. Actual energy consumption Controller
will depend on how the appliance is used and where it is located.

59

P049-080.indd 59 13.12.12 1:19:50 PM


Optimum Airflow
Individual Vane Settings Wide Airflow Image of multi-directional
Optimum airflow settings provide maximum Wide-angle outlets distribute airflow air conditioning

comfort throughout the room. to all corners of the room.


In addition to the selection of variable airflow patterns (i.e., 2-, The outlets are larger than those of previous
3- or 4-way), this function allows the independent selection of models and the shape has been improved for
vertical airflow levels for each vane, thereby maintaining a com- better wide-angle ventilation.
fortable room environment with even temperature distribution.

2-, 3-, 4-way airflow


pattern selection
Previous
* Optional shuffle placement is required
for 2- and 3-way patterns.
model

Individual Vane
Wide Airflow
Airflow direction at each vane Horizontal
New 4-Way Ceiling Cassette Setting
can be set using the wired remote
controller. This function is only The combination of individual vane setting,
available when indoor unit Fixed which enables the optimal outlet setting for
connects with PUHZ series. Adjustable
Downward each room layout, and the wide airflow function
works to ensure even temperature distribution
throughout each room. The result is uniformly
72 airflow patterns comfortable air conditioning.

Wave Airflow – Thoroughly warming all corners of the room!


Wave Airflow Operation
“Wave Airflow” is essentially the advanced control of the vanes
directing the airflow from the unit. Blown-air is repeated dispersed
from the unit in horizontal and downward directions at time-lagged
intervals to provide uniform heating throughout the room.
Downward Downward Downward Downward
Thermograph of Wave Control Effect ✽ Wave Airflow is possible only when using the heating mode
Horizontal Airflow Wave Airflow

Indoor Unit Indoor Unit

Temperature distribution comparison approxi-


mately 20min after turning on a PLA-RP71BA
Temperature gap Temperature gap is minimized. 4-Way ceiling cassette. The measurement point
Uneven temperature distribution Warm air is supplied throughout the room, for comparison is a plane 1.2m above the floor.
minimizing uneven temperature distribution.

Equipped with High- and Low-ceiling Modes


Units are equipped with high- and low-ceiling operation modes that make it possible to switch the airflow volume to match room height. The ability
to choose the optimum airflow volume makes it possible to optimize the breezy sensation felt throughout the room.
✽ 100-140 class ■ Airflow Range
Model 35-71 class 100-140 class
4.5m✽
3.2m✽ 2.7m✽ Airflow High-ceiling Standard Low-ceiling High-ceiling Standard Low-ceiling
pattern setting setting setting setting setting setting

4-Way 3.5m 2.4m 2.5m 4.5m 3.2m 2.7m


3-Way 3.5m 3.0m 2.7m 4.5m 3.6m 3.0m
4-way airflow with 4-way airflow with 4-way airflow with 2-Way 3.5m 3.3m 3.0m 4.5m 4.0m 3.3m
high-ceiling setting standard setting low-ceiling setting

Horizontal Airflow Automatic Air-speed Adjustment


A “Horizontal Airflow” function has been An automatic air-speed mode that adjusts airflow speed automati-
added to reduce drafty-feeling distribution. cally is adopted to maintain comfortable room conditions at all
Horizontal Airflow prevents cold drafts from times. This setting automatically adjusts the air-speed to conditions
striking the body directly, thereby keeping that match the room environment.
the body from becoming over-chilled.
[Airflow Distribution] At the start of heating/cooling opera-
PLA-RP125BA tion, the airflow is set to high-speed
Flow angle, cooling at 20°C (ceiling height 3.2m) to quickly heat/cool the room. Strong
3.2
3 1.0 2.0 3.0 4.0 5.0 (m/s)

2 A more
Height (m)

horizontal airflow
Horizontal is achieved using
1 Airflow the new mode.
When the room temperature reaches
0 the desired setting, the airflow speed
5 4 3 2 1 0
Floor distribution (m) is decreased automatically for stable
✽ Smudge spots on the ceiling may form where the airflow is not evenly distributed. comfortable heating/cooling operation. Gentle

60

P049-080.indd 60 13.12.12 1:19:53 PM


DOES HAVING COLD FEET BOTHER YOU?
The “i-see Sensor” is the answer to your problems!

Heating Cooling
Mode Mode
Warm air rises Legs and feet
to the ceiling! feel cold!

Even though the temperature on At the beginning of operation, the


the remote controller is at a preset room is nice and cool; but before
In heating mode, the upper
temperature, the temperature at When cooling, the legs long the temperature at floor level
body gets warm but legs floor level remains cold. As a result, and feet get too cold, drops, causing the feeling of being
and feet remain chilly. there’s no feeling of getting warmer. chilling the entire body.
too cold.

■ i-see Sensor Panel


“ ” temperature-sensing ■ i-see Sensor Operation

technology improves energy efficiency The i-see Sensor rotates 90° at intervals of
5 sec, accurately measuring the temperature
throughout the room (covering entire floor space).
and enhances room comfort PLP-6BAE

or
■ Corner Panel Only (Option)
The “i-see Sensor” is an innovative Mitsubishi Electric technology 90° 90° 90°
rotation rotation rotation
that uses a radiation-based sensor to monitor temperature through-
5 sec 5 sec 5 sec 5 sec
out an entire room. When connected to the air conditioner control measurement measurement measurement measurement
PAC-SA1 ME-E
panel, i-see Sensor works to maximize room comfort.

A comfortable room environment cannot be maintained by monitoring


only the temperature at the ceiling.
Without “i-see Sensor” Intake-air temperature sensor Intake-air temperature sensor Equipped with 4-Way
Only intake-air temperature Cassette equipped with Ceiling “i-see Sensor”
the i-see Sensor measures
at the ceiling was measured, upper and lower areas. Both the floor temperature
Cassette without the
tending to overlook uneven i-see Sensor measures temperature
360° and intake-air temperature
sensing
in this area only.
temperature distribution at are measured to provide op-
2.7m
floor level. eration that creates a com-
fortable room environment
from ceiling to floor.
11.5m

In Heating Mode When you want the temperature felt to be 20°


Temperature setting: 20°C
Temperature setting: 20°C (w/o i-see Sensor) (w/ i-see Sensor + Automatic Air-speed Adjustment)
37°C 37°C

Room air
25°C 25°C
warmed to
floor level
13°C 13°C
Temperature gap Temperature gap minimized
Temperature felt: 17°C (floor level 14°C) Temperature felt: 20°C (floor level 20°C)
Warm air rises to the ceiling. This causes poor heating at floor level, The i-see Sensor detects the temperature at the floor while the
leaving legs and feet feeling cold. Automatic Air-speed Adjustment eliminates uneven temperature
distribution by thoroughly warming the air down to the floor.

In Cooling Mode Comfortable


When you want the temperature felt to be 28°C without excess
Temperature setting: 28°C chilliness
Temperature setting: 26–27°C (w/o i-see Sensor)
(w/ i-see Sensor + Automatic Air-speed Adjustment)
Because it takes longer to cool down the i-see Sensor computes the temperature felt by
Floor-level temperature floor-level temperature than the air tem- monitoring both intake-air temperature and floor-
Floor-level temperature
perature, a temperature setting of 26–27°C level temperature. The air temperature is adjusted
Temperature felt
is required. Temperature felt
at initial start-up, ensuring that the temperature
felt reaches a temperature setting.
28°C
26.5°C 28°C
26.5°C
Air temperature Temperature felt drops
(intake-air temperature) Air temperature No drop in temperature felt
(intake-air temperature)
At start-up
(approx. 30 min) After specified time At start-up
(approx. 30 min) After specified time
32°C
Temperature distribution 32°C
Temperature distribution
23°C
23°C

14°C
14°C
Temperature felt: 26.5°C
The temperature felt drops according to the drop in floor-level Temperature Felt: 28°C
temperature. If the floor-level temperature is not monitored during Air temperature is adjusted according to the floor temperature to
long cooling operation, the temperature felt becomes chilly. keep the temperature felt at 28°C.

61

P049-080.indd 61 13.12.12 1:19:56 PM


SERIES SELECTION
Power Inverter Series
Indoor Unit Outdoor Unit

For Single

PLA-ZRP35/50/60/71/100/125/140BA PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100/125/140

Standard Panel
PLP-6BA (only Panel)
PLP-6BALM (with wireless remote controller)

Automatic Filter Elevation Panel For Multi


PLP-6BAJ (only Panel) (Twin/Triple/Quadruple)
Standard Panel with “i-see Sensor”
PLP-6BAE (only Panel)
PLP-6BALME (with wireless remote controller) PUHZ-ZRP71 PUHZ-ZRP100/125/140 PUHZ-RP200/250

Remote Controller ✽ 35-71 100-250

Joint Lap Vector Sine Wave DC Scroll DC Fan Motor

35-140 35-71

Heat Caulking
Fixing Method
Vector-Wave Grooved Piping

Optional Optional

Standard Inverter Series


Indoor Unit Outdoor Unit

For Single

SUZ-KA35 SUZ-KA50/60/71 PUHZ-P100 PUHZ-P125/140


PLA-RP35/50/60/71/100/125/140BA

Standard Panel
PLP-6BA (only Panel)
PLP-6BALM (with wireless remote controller)

Automatic Filter Elevation Panel


PLP-6BAJ (only Panel) For Multi (Twin/Triple/Quadruple)

Standard Panel with “i-see Sensor”


PLP-6BAE (only Panel)
PLP-6BALME (with wireless remote controller) PUHZ-P100 PUHZ-P125/140/200/250

Remote Controller ✽ 35-71 100-250 71-140 200/250

Joint Lap Vector Sine Wave DC Rotary DC Scroll

100-250 35-140 25-71

Heat Caulking
Fixing Method
DC Fan Motor Vector-Wave Grooved Piping

Optional Optional

✽ Enclosed in PLP-6BALM/PLP-6BALME

PLZ-ZRP / RP BA Indoor Unit Combinations Indoor unit combinations shown below are possible.

Outdoor Unit Capacity

Indoor Unit Combination For Single For Twin For Triple For Quadruple

35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250

Power Inverter (PUHZ-ZRP/RP) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – 35x2 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4

Distribution Pipe – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

Standard Inverter (PUHZ-P & SUZ) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – – 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4

Distribution Pipe – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

62

P049-080.indd 62 13.12.12 1:19:59 PM


PLZ-RP SERIES
POWER INVERTER Optional Optional Optional

60-140V/200/250

Please fill out the requested information


Please fill out the requested information

Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PLA- PLA- PLA- PLA-
PLA-ZRP100BA PLA-ZRP125BA PLA-ZRP140BA
ZRP35BA ZRP50BA ZRP60BA ZRP71BA
Outdoor Unit PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
ZRP35VKA ZRP50VKA ZRP60VHA ZRP71VHA ZRP100VKA ZRP100YKA ZRP125VKA ZRP125YKA ZRP140VKA ZRP140YKA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 3.6 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Min - Max kW 1.6 - 4.5 2.3 - 5.6 2.7 - 6.5 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0 5.5 - 14.0 6.2 - 15.0 6.2 - 15.0
Total Input Rated kW 0.79 1.43 1.78 1.77 2.60 2.60 3.87 3.87 4.37 4.37
EER – – – – – – 3.23 3.23 3.07 3.07
EEL Rank – – – – – – – – – –
Design Load kW 3.6 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Annual Electricity Consumption*2 kWh/a 185 272 350 370 538 549 725 736 770 781
SEER 6.8 6.4 6.1 6.7 6.5 6.4 6.0*4 5.9*4 6.1*4 6.0*4
Energy Efficiency Class A++ A++ A++ A++ A++ A++ – – – –
Heating Capacity Rated kW 4.1 6.0 7.0 8.0 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.6 - 5.2 2.5 - 7.3 2.8 - 8.2 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0
Season) Total Input Rated kW 0.86 1.57 2.04 1.99 2.61 2.61 3.67 3.67 4.70 4.70
COP – – – – – – 3.81 3.81 3.40 3.40
EEL Rank – – – – – – – – – –
Design Load kW 2.4 3.8 4.4 4.7 7.8 7.8 9.3 9.3 10.6 10.6
Declared Capacity at reference design temperature kW 2.4 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at bivalent temperature kW 2.4 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at operation limit temperature kW 2.2 (–11°C) 3.7 (–11°C) 2.8 (–20°C) 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0 0 0 0 0
Annual Electricity Consumption*2 kWh/a 729 1162 1462 1476 2410 2410 3180 3180 3324 3324
SCOP 4.6 4.6 4.2 4.5 4.6 4.6 4.1*4 4.1*4 4.5*4 4.5*4
Energy Efficiency Class A++ A++ A+ A+ A++ A++ – – – –
Operating Current (max) A 13.3 13.3 19.3 19.5 27.2 8.7 27.3 10.3 29.1 12.1
Indoor Input Rated kW 0.04 0.04 0.04 0.05 0.08 0.08 0.09 0.09 0.12 0.12
Unit Operating Current (max) A 0.28 0.30 0.30 0.45 0.74 0.74 0.80 0.80 1.07 1.07
Dimensions <Panel> H × W × D mm 258 - 840 - 840 <35 - 950 - 950> 298 - 840 - 840 <35 - 950 - 950>
Weight <Panel> kg 23 <6> 23 <6> 23 <6> 25 <6> 26 <6> 26 <6> 27 <6> 27 <6> 27 <6> 27 <6>
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 11 - 13 - 15 - 16 12 - 14 - 16 - 18 12 - 14 - 16 - 18 17 - 19 - 21 - 23 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 27 - 28 - 29 - 31 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 34 - 36 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
Sound Level (PWL) dB(A) 54 55 55 58 65 65 66 66 70 70
Outdoor Dimensions H×W×D mm 630 - 809 - 300 943 - 950 - 330 (+30) 1338 - 1050 - 330 (+30)
Unit Weight kg 43 46 67 67 116 124 116 126 119 132
Air Volume Cooling m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Heating m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Sound Level (SPL) Cooling dB(A) 44 44 47 47 49 49 50 50 50 50
Heating dB(A) 46 46 48 48 51 51 52 52 52 52
Sound Level (PWL) Cooling dB(A) 65 65 67 67 69 69 70 70 70 70
Operating Current (max) A 13.0 13.0 19.0 19.0 26.5 8.0 26.5 9.5 28.0 11.0
Breaker Size A 16 16 25 25 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 75 75 75 75 75 75
Max. Height Out-In m 30 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –11 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.

PLZ-P
SPLZ-PSERIES
PUHZ

SERIES
STANDARD INVERTER Optional Optional Optional

PUHZ PUHZ PUHZ SUZ PUHZ PUHZ PUHZ

Please fill out the requested information


Please fill out the requested information

Optional Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PLA- PLA- PLA- PLA-
PLA-RP100BA PLA-RP125BA PLA-RP140BA2
RP35BA RP50BA RP60BA RP71BA
Outdoor Unit SUZ- SUZ- SUZ- SUZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
KA35VA4 KA50VA4 KA60VA4 KA71VA4 P100VHA4 P100YHA2 P125VHA3 P125YHA P140VHA3 P140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VA4 • VHA4 • VHA3:230 / Single / 50, YHA2 • YHA:400 / Three / 50
Cooling Capacity Rated kW 3.6 5.5 6.1 7.1 9.4 9.4 12.3 12.3 13.6 13.6
Min - Max kW 1.4 - 3.9 2.3 - 5.6 2.3 - 6.3 2.8 - 8.1 4.9 - 11.2 4.9 - 11.2 5.5 - 14.0 5.5 - 14.0 5.5 - 15.0 5.5 - 15.0
Total Input Rated kW 1.090 1.660 1.840 2.100 3.120 3.120 4.090 4.090 5.210 5.210
EER – – – – – – 3.01 3.01 2.61 2.61
EEL Rank – – – – – – B B D D
Design Load kW 3.6 5.5 6.1 7.1 9.4 9.4 – – – –
Annual Electricity Consumption*2 kWh/a 210 321 356 429 628 628 – – – –
SEER 6.0 6.0 6.0 5.8 5.2 5.2 – – – –
Energy Efficiency Class A+ A+ A+ A+ A A – – – –
Heating Capacity Rated kW 4.1 6.0 6.9 8.0 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.7 - 5.0 1.7 - 7.2 2.5 - 8.0 2.6 - 10.2 4.5 - 12.5 4.5 - 12.5 5.0 - 16.0 5.0 - 16.0 5.0 - 18.0 5.0 - 18.0
Season) Total Input Rated kW 1.040 1.750 1.970 2.247 3.280 3.280 4.110 4.110 4.980 4.980
COP – – – – – – 3.41 3.41 3.21 3.21
EEL Rank – – – – – – B B C C
Design Load kW 2.6 4.3 4.6 5.8 8.0 8.0 – – – –
Declared Capacity at reference design temperature kW 2.3 (–10°C) 3.8 (–10°C) 4.0 (–10°C) 4.7 (–10°C) 6.3 (–10°C) 6.3 (–10°C) – – – –
at bivalent temperature kW 2.3 (–7°C) 3.8 (–7°C) 4.0 (–7°C) 5.1 (–7°C) 7.1 (–7°C) 7.1 (–7°C) – – – –
at operation limit temperature kW 2.3 (–10°C) 3.8 (–10°C) 4.0 (–10°C) 4.7 (–10°C) 5.0 (–15°C) 5.0 (–15°C) – – – –
Back Up Heating Capacity kW 0.3 0.5 0.6 1.1 1.7 1.7 – – – –
Annual Electricity Consumption*2 kWh/a 867 1503 1570 1913 2945 2945 – – – –
SCOP 4.2 4.0 4.1 4.3 3.8 3.8 – – – –
Energy Efficiency Class A+ A+ A+ A+ A A – – – –
Operating Current (max) A 8.4 12.4 14.4 16.6 28.9 13.9 29.0 14.0 30.5 14.0
Indoor Input Rated kW 0.03 0.05 0.05 0.07 0.14 0.14 0.15 0.15 0.15 0.15
Unit Operating Current (max) A 0.22 0.36 0.36 0.51 0.94 0.94 1.00 1.00 1.00 1.00
Dimensions <Panel> H × W × D mm 258 - 840 - 840 <35 - 950 - 950> 298 - 840 - 840 <35 - 950 - 950>
Weight <Panel> kg 22 <6> 22 <6> 23 <6> 23 <6> 25 <6> 25 <6> 25 <6> 25 <6> 27 <6> 27 <6>
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 11 - 12 - 13 - 15 12 - 14 - 16 - 18 12 - 14 - 16 - 18 14 - 16 - 18- 21 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 27 - 28 - 29 - 31 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
Sound Level (PWL) dB(A) 54 55 55 56 62 62 63 63 70 70
Outdoor Dimensions H×W×D mm 550 - 800 - 285 880 - 840 - 330 943 - 950 - 330 (+30) 1350 - 950 - 330 (+30)
Unit Weight kg 35 54 50 53 75 77 99 101 99 101
Air Volume Cooling m3/min 36.3 44.6 40.9 50.1 60.0 60.0 100.0 100.0 100.0 100.0
Heating m3/min 34.8 44.6 49.2 48.2 60.0 60.0 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 49 52 55 55 50 50 51 51 52 52
Heating dB(A) 50 52 55 55 54 54 55 55 56 56
Sound Level (PWL) Cooling dB(A) 62 65 65 69 70 70 71 71 73 73
Operating Current (max) A 8.2 12.0 14.0 16.1 28.0 13.0 28.0 13.0 29.5 13.0
Breaker Size A 10 20 20 20 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 20 30 30 30 50 50 50 50 50 50
Max. Height Out-In m 12 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –10 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –10 ~ +24 –10 ~ +24 –10 ~ +24 –10 ~ +24 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
63 *3 Optional air protection guide is required where ambient temperature is lower than –5°C.

P049-080.indd 63 13.12.12 1:20:02 PM


PLZ-RP SERIES
POWER INVERTER
Optional Optional

60-140V/200/250
Optional

Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PLA- PLA- PLA- PLA-
PLA-RP100BA PLA-RP125BA PLA-RP140BA2
RP35BA RP50BA RP60BA RP71BA
Outdoor Unit PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
ZRP35VKA ZRP50VKA ZRP60VHA ZRP71VHA ZRP100VKA ZRP100YKA ZRP125VKA ZRP125YKA ZRP140VKA ZRP140YKA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 3.5 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Min - Max kW 1.6 - 4.5 2.3 - 5.6 2.7 - 6.5 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0 5.5 - 14.0 6.2 - 15.0 6.2 - 15.0
Total Input Rated kW 0.88 1.43 1.90 1.87 2.63 2.63 3.99 3.99 4.40 4.40
EER – – – – – – 3.13 3.13 3.05 3.05
EEL Rank – – – – – – – – – –
Design Load kW 3.5 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Annual Electricity Consumption*2 kWh/a 189 311 371 387 569 580 875 886 849 860
SEER 6.5 5.6 5.7 6.4 6.2 6.0 5.0*4 4.9*4 5.5*4 5.5*4
Energy Efficiency Class A++ A+ A+ A++ A++ A+ – – – –
Heating Capacity Rated kW 4.1 6.0 7.0 8.0 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.6 - 5.2 2.5 - 7.3 2.8 - 8.2 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0
Season) Total Input Rated kW 0.96 1.82 2.17 2.21 3.01 3.01 3.91 3.91 4.76 4.76
COP – – – – – – 3.58 3.58 3.36 3.36
EEL Rank – – – – – – – – – –
Design Load kW 2.3 3.8 4.4 4.7 7.8 7.8 9.3 9.3 10.6 10.6
Declared Capacity at reference design temperature kW 2.3 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at bivalent temperature kW 2.3 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at operation limit temperature kW 2.2 (–11°C) 3.7 (–11°C) 2.8 (–20°C) 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0 0 0 0 0
Annual Electricity Consumption*2 kWh/a 750 1313 1576 1521 2652 2652 3304 3304 3746 3746
SCOP 4.3 4.1 3.9 4.3 4.1 4.1 3.9*4 3.9*4 4.0*4 4.0*4
Energy Efficiency Class A+ A+ A A+ A+ A+ – – – –
Operating Current (max) A 13.2 13.4 19.4 19.5 27.4 8.9 27.5 10.5 29.1 12.1
Indoor Input Rated kW 0.03 0.05 0.05 0.07 0.14 0.14 0.15 0.15 0.16 0.16
Unit Operating Current (max) A 0.22 0.36 0.36 0.51 0.94 0.94 1.00 1.00 1.07 1.07
Dimensions <Panel> H × W × D mm 258 - 840 - 840 <35 - 950 - 950> 298 - 840 - 840 <35 - 950 - 950>
Weight <Panel> kg 22 <6> 22 <6> 23 <6> 23 <6> 25 <6> 25 <6> 25 <6> 25 <6> 27 <6> 27 <6>
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 11 - 12 - 13 - 15 12 - 14 - 16 - 18 12 - 14 - 16 - 18 14 - 16 - 18 - 21 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 27 - 28 - 29 - 31 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
Sound Level (PWL) dB(A) 54 55 55 56 62 62 63 63 70 70
Outdoor Dimensions H×W×D mm 630 - 809 - 300 943 - 950 - 330 (+30) 1338 - 1050 - 330 (+30)
Unit Weight kg 43 46 67 67 116 124 116 126 119 132
Air Volume Cooling m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Heating m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Sound Level (SPL) Cooling dB(A) 44 44 47 47 49 49 50 50 50 50
Heating dB(A) 46 46 48 48 51 51 52 52 52 52
Sound Level (PWL) Cooling dB(A) 65 65 67 67 69 69 70 70 70 70
Operating Current (max) A 13.0 13.0 19.0 19.0 26.5 8.0 26.5 9.5 28.0 11.0
Breaker Size A 16 16 25 25 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 75 75 75 75 75 75
Max. Height Out-In m 30 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –11 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.

PUHZ

PLZ-P
SPLZ-PSERIES
SERIES
STANDARD INVERTER
Optional
PUHZ
Optional
PUHZ PUHZ SUZ
Optional

PUHZ PUHZ PUHZ

Optional Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PLA-ZRP100BA PLA-ZRP125BA PLA-ZRP140BA
Outdoor Unit PUHZ-P100VHA4 PUHZ-P100YHA2 PUHZ-P125VHA3 PUHZ-P125YHA PUHZ-P140VHA3 PUHZ-P140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50 400 / Three / 50 230 / Single / 50 400 / Three / 50 230 / Single / 50 400 / Three / 50
Cooling Capacity Rated kW 9.4 9.4 12.3 12.3 13.6 13.6
Min - Max kW 4.9 - 11.2 4.9 - 11.2 5.5 - 14.0 5.5 - 14.0 5.5 - 15.0 5.5 - 15.0
Total Input Rated kW 3.082 3.082 4.020 4.020 5.171 5.171
EER - – 3.06 3.06 2.63 2.63
EEL Rank - – B B D D
Design Load kW 9.4 9.4 – – – –
Annual Electricity Consumption*2 kWh/a 610 610 – – – –
SEER 5.4 5.4 – – – –
Energy Efficiency Class A A – – – –
Heating Capacity Rated kW 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 4.5 - 12.5 4.5 - 12.5 5.0 - 16.0 5.0 - 16.0 5.0 - 18.0 5.0 - 18.0
Season) Total Input Rated kW 3.137 3.137 3.989 3.989 4.938 4.938
COP – – 3.51 3.51 3.24 3.24
EEL Rank – – B B C C
Design Load kW 8.0 8.0 – – – –
Declared Capacity at reference design temperature kW 6.3 (–10°C) 6.3 (–10°C) – – – –
at bivalent temperature kW 7.1 (–7°C) 7.1 (–7°C) – – – –
at operation limit temperature kW 5.0 (–15°C) 5.0 (–15°C) – – – –
Back Up Heating Capacity kW 1.7 1.7 – – – –
Annual Electricity Consumption*2 kWh/a 2800 2800 – – – –
SCOP 4.0 4.0 – – – –
Energy Efficiency Class A+ A+ – – – –
Operating Current (max) A 28.7 13.7 28.8 13.8 30.6 14.1
Indoor Input Rated kW 0.08 0.08 0.09 0.09 0.12 0.12
Unit Operating Current (max) A 0.74 0.74 0.80 0.80 1.07 1.07
Dimensions <Panel> H × W × D mm 298 - 840 - 840 <35 - 950 - 950>
Weight <Panel> kg 26 <6> 26 <6> 27 <6> 27 <6> 27 <6> 27 <6>
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
Sound Level (PWL) dB(A) 65 65 66 66 70 70
Outdoor Dimensions H×W×D mm 943 - 950 - 330 (+30) 1350 - 950 - 330 (+30)
Unit Weight kg 75 77 99 101 99 101
Air Volume Cooling m3/min 60.0 60.0 100.0 100.0 100.0 100.0
Heating m3/min 60.0 60.0 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 50 50 51 51 52 52
Heating dB(A) 54 54 55 55 56 56
Sound Level (PWL) Cooling dB(A) 70 70 71 71 73 73
Operating Current (max) A 28.0 13.0 28.0 13.0 29.5 13.0
Breaker Size A 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 50 50
Max. Height Out-In m 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

64

P049-080.indd 64 13.12.12 1:20:02 PM


PKA-RP35/50HAL

PKA
PKA-RP60/71/100KAL

SERIES
The compact, wall-mounted indoor units offer the convenience of simple installation,
and a large product line-up (RP35-RP100 models) ensures a best-match solution.
Designed for highly efficient energy savings, the PKA Series is the answer to your
air conditioning needs.

Flat Panel & Pure White Finish


A flat panel layout has been adopted for all models. Pursuing a design that harmonizes with virtually any interior, the unit colour has been changed
from white to pure white.
Flat panel is
easy to clean!

PKA-RP GAL PKA-RP HAL

PKA-RP FAL PKA-RP KAL

Compact Indoor Units


Indoor unit width has been reduced by as much as 510mm (RP100). Units take up much less space, greatly increasing installation possibilities.

PKA-RP35/50HAL 92mm DOWN* PKA-RP60/71KAL 230mm DOWN* PKA-RP100KAL 510mm DOWN*

*Compared to PKA-RP35/50GAL *Compared to PKA-RP60/71FAL *Compared to PKA-RP100FAL

ErP Lot 10 Compliant with High Energy-efficiency Achieving SEER/SCOP


Rank A, A+ and A++
Highly efficient indoor unit heat exchangers and and newly designed power inverters (PUHZ-ZRP) contribute to an amazing reduction in electricity
consumption throughout a year, and have resulted in models in the full-capacity range attaining the rank A, A+ and A++ energy savings rating.

SEER SEER SEER SEER


SEER SEER A++ A++ A++ A+
A+ A SCOP SCOP
SCOP SCOP SCOP SCOP
A A+ A+ A+ A++ A+
6.3 6.5 6.1 6.0
Minimum SEER 3.6 5.7 5.3
3.9 4.0 4.2 4.3 4.0 4.0
Minimum SCOP 3.4

Cooling PKA-RP35HAL PKA-RP50HAL PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL PKA-RP100KAL


Heating PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA

Drain Pump Option Available with All Models Multi-function Wired Remote Controller
Installation of the drain pump enables a drain outlet as high as 800mm In addition to using the wireless remote controller that comes as
above the base of the indoor unit. Drain water can be discharged easily standard equipment, PAR-31MAA and PAC-YT52CRA wired remote
even if the surface where the wall-mounted unit does not have direct controllers can be used as well.
access outside, increasing the degree of freedom for installation. ✽ Connection to PAR-31MAA /PAC-YT52CRA requires PAC-SH29TC-E (optional).

Main Functions
Drain pump • Night Setback
Indoor unit • Energy- saving Mode
800mm • Multi Language
• Weekly Timer
• Refrigerant Leak Check
✽ For details, please refer to pages 23-26.

65

P049-080.indd 65 13.12.12 1:20:02 PM


SERIES SELECTION
Power Inverter Series
Indoor Unit Outdoor Unit

For Single

PKA-RP35/50HAL PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100

For Multi
(Twin/Triple/Quadruple)
PKA-RP60/71/100KAL

PUHZ-ZRP71 PUHZ-ZRP100/125/140 PUHZ-RP200/250

Remote Controller
35-71 100-250

Joint Lap Vector Sine Wave DC Scroll DC Fan Motor

35-140 35-71

Heat Caulking
Fixing Method
Vector-Wave Grooved Piping

Optional (✽) Optional (✽)

Standard Inverter Series


Indoor Unit Outdoor Unit

For Single

PKA-RP35/50HAL PUHZ-P100

For Multi (Twin/Triple/Quadruple)

PKA-RP60/71/100KAL

PUHZ-P100 PUHZ-P125/140/200/250

Remote Controller
100-250 100-140 200/250

Vector Sine Wave DC Rotary DC Scroll DC Fan Motor

100-250 100-140

Vector-Wave Grooved Piping

Optional (✽) Optional (✽)

(✽) PAC-SH29TC-E is required (optional)

PKZ-RP HA/KA Indoor Unit Combinations Indoor unit combinations shown below are possible.

Outdoor Unit Capacity

Indoor Unit Combination For Single For Twin For Triple For Quadruple

35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250

Power Inverter (PUHZ-ZRP / RP) 35x1 50x1 60x1 71x1 100x1 – – – – 35x2 50x2 60x2 71x2 100x2 – 50x3 60x3 71x3 50x4 60x4

Distribution Pipe – – – – – – – – – MSDD-50TR-E MSDD-50WR-E – MSDT-111R-E MSDF-1111R-E

Standard Inverter (PUHZ-P ) – – – – 100x1 – – – – – 50x2 60x2 71x2 100x2 – 50x3 60x3 71x3 50x4 60x4

Distribution Pipe – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E – MSDT-111R-E MSDF-1111R-E

66

P049-080.indd 66 13.12.12 1:20:06 PM


PKZ-RP SERIES
60-140V/200/250

POWER INVERTER Optional Optional Optional Optional Optional Optional

Please fill out the requested information


Please fill out the requested information

Optional Optional

Type Inverter Heat Pump


Indoor Unit PKA-RP35HAL PKA-RP50HAL PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL
Outdoor Unit PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 3.6 4.6 6.1 7.1 10.0 10.0
Min - Max kW 1.6 - 4.5 2.3 - 5.6 2.7 - 6.7 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4
Total Input Rated kW 0.94 1.41 1.60 1.80 2.65 2.65
EER – – – – – –
EEL Rank – – – – – –
Design Load kW 3.6 4.6 6.1 7.1 10.0 10.0
2
Annual Electricity Consumption* kWh/a 221 304 336 381 572 583
SEER 5.7 5.3 6.3 6.5 6.1 6.0
Energy Efficiency Class A+ A A++ A++ A++ A+
Heating Capacity Rated kW 4.1 5.0 7.0 8.0 11.2 11.2
(Average Min - Max kW 1.6 - 5.2 2.5 - 7.3 2.8 - 8.2 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0
Season) Total Input Rated kW 1.07 1.50 1.96 2.19 3.04 3.04
COP – – – – – –
EEL Rank – – – – – –
Design Load kW 2.4 3.3 4.4 4.7 7.8 7.8
Declared Capacity at reference design temperature kW 2.4 (–10°C) 3.3 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C)
at bivalent temperature kW 2.4 (–10°C) 3.3 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C)
at operation limit temperature kW 2.2 (–11°C) 3.2 (–11°C) 2.8 (–20°C) 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0
2
Annual Electricity Consumption* kWh/a 847 1160 1473 1532 2763 2763
SCOP 3.9 4.0 4.2 4.3 4.0 4.0
Energy Efficiency Class A A+ A+ A+ A+ A+
Operating Current (max) A 13.4 13.4 19.4 19.4 27.1 8.6
Indoor Input Rated kW 0.04 0.04 0.06 0.06 0.08 0.08
Unit Operating Current (max) A 0.4 0.4 0.43 0.43 0.57 0.57
Dimensions <Panel> H × W × D mm 295 - 898 - 249 365 - 1170 - 295
Weight <Panel> kg 13 13 21 21 21 21
Air Volume [Lo-Mid-Hi] m3/min 9 - 10.5 - 12 9 - 10.5 - 12 18 - 20 - 22 18 - 20 - 22 20 - 23 - 26 20 - 23 - 26
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 36 - 40 - 43 36 - 40 - 43 39 - 42 - 45 39 - 42 - 45 41 - 45 - 49 41 - 45 - 49
Sound Level (PWL) dB(A) 60 60 64 64 65 65
Outdoor Dimensions H×W×D mm 630 - 809 - 300 943 - 950 - 330 (+30) 1338 - 1050 - 330 (+30)
Unit Weight kg 43 46 67 67 116 124
3
Air Volume Cooling m /min 45.0 45.0 55.0 55.0 110.0 110.0
Heating m3/min 45.0 45.0 55.0 55.0 110.0 110.0
Sound Level (SPL) Cooling dB(A) 44 44 47 47 49 49
Heating dB(A) 46 46 48 48 51 51
Sound Level (PWL) Cooling dB(A) 65 65 67 67 69 69
Operating Current (max) A 13.0 13.0 19.0 19.0 26.5 8.0
Breaker Size A 16 16 25 25 32 16
Ext. Diameter Liquid / Gas mm 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 75 75
Max. Height Out-In m 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –11 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

PKZ-P SERIES
STANDARD INVERTER Optional Optional Optional Optional Optional Optional

Please fill out the requested information


Please fill out the requested information

Optional Optional

Type Inverter Heat Pump


Indoor Unit PKA-RP100KAL
Outdoor Unit PUHZ-P100VHA4 PUHZ-P100YHA2
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50 400 / Three / 50
Cooling Capacity Rated kW 9.4 9.4
Min - Max kW 4.9 - 11.2 4.9 - 11.2
Total Input Rated kW 3.120 3.120
Design Load kW 9.4 9.4
Annual Electricity Consumption*2 kWh/a 686 686
SEER 4.8 4.8
Energy Efficiency Class B B
Heating Capacity Rated kW 11.2 11.2
(Average Min - Max kW 4.5 - 12.5 4.5 - 12.5
Season) Total Input Rated kW 3.490 3.490
Design Load kW 7.0 7.0
Declared Capacity at reference design temperature kW 5.6 (–10°C) 5.6 (–10°C)
at bivalent temperature kW 6.2 (–7°C) 6.2 (–7°C)
at operation limit temperature kW 4.5 (–15°C) 4.5 (–15°C)
Back Up Heating Capacity kW 1.4 1.4
Annual Electricity Consumption*2 kWh/a 2579 2579
SCOP 3.8 3.8
Energy Efficiency Class A A
Operating Current (max) A 28.6 13.6
Indoor Input Rated kW 0.08 0.08
Unit Operating Current (max) A 0.57 0.57
Dimensions <Panel> H × W × D mm 365 - 1170 - 295
Weight <Panel> kg 21 21
3
Air Volume [Lo-Mid-Hi] m /min 20 - 23 - 26 20 - 23 - 26
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 41 - 45 - 49 41 - 45 - 49
Sound Level (PWL) dB(A) 65 65
Outdoor Dimensions H×W×D mm 943 - 950 - 330 (+30)
Unit Weight kg 75 77
Air Volume Cooling m3/min 60.0 60.0
Heating m3/min 60.0 60.0
Sound Level (SPL) Cooling dB(A) 50 50
Heating dB(A) 54 54
Sound Level (PWL) Cooling dB(A) 70 70
Operating Current (max) A 28.0 13.0
Breaker Size A 32 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50
Max. Height Out-In m 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

67

P049-080.indd 67 13.12.12 1:20:10 PM


PCA-RP35/50/60/71/100/125/140KAQ

PCA-KA SERIES
A stylish new indoor unit design and airflow settings for both high- and low-ceiling
interiors expand installation possibilities. Together with exceptional energy-saving
performance, these units are the solution to diversified air conditioning needs.

Stylish Indoor Unit Design


A stylish square-like design is adopted for the indoor units of all models. As a result,
the units blend in better with the ceiling.

PCA-GA PCA-KAQ

ErP Lot 10 Compliant with High Energy-efficiency Achieving SEER/SCOP Rank A, A+ and A++
A direct-current (DC) fan motor is isntalled in the indoor unit, increasing the seasonal energy efficiency of newly designed Power Inverter series
(PUHZ-ZRP) and resulting in the full capacity models comply ErP Lot 10 with energy ranking A+/A++ for cooling and A/A+ for heating. This contrib-
ute to an impressive reduction in the cost of annual electricity.

SEER SEER SEER


SEER A++ SEER SEER
A++ A+ A++ A+ A+
SCOP SCOP SCOP SCOP SCOP SCOP
A+ A+ A+ 6.6 A+ A A
6.1 6.0 6.2 6.0 5.9
Minimum SEER 3.6 5.2 5.2 5.3 5.2
4.2 4.2 4.4 4.4
Minimum SCOP 3.4 4.1 4.2 4.3 4.3 3.9 3.9

Cooling PCA-RP35KAQ PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP125KAQ PCA-RP140KAQ PCA-RP140KAQ
Heating PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA PUHZ-ZRP125VKA PUHZ-ZRP125YKA PUHZ-ZRP140VKA PUHZ-ZRP140YKA
✽ For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.

Optional Drain Pump for Full-capacity Models Outside-air Intake


The pumping height of the op- ● Outside-air intake characteristics
● Drain pump Units are equipped with
Static pressure (Pa)

50
installation possible
tional drain pump has been in- Drainage outlet a knock-out hole that 0
– 50
can be 600mm
creased from 400mm to 600mm, above ceiling
enables the induction of – 100
– 150 PCA-RP100-140KAQ
expanding flexibility in choosing surface fresh outside-air. – 200
PCA-RP60/71KAQ
PCA-RP35/50KAQ
unit location during installation Ceiling surface – 250
– 300
work. 0 1 2
Airflow volume (m3/min)
3 4
RP100 –140
PCA-RP60/71KAQ
PCA-RP35/50KAQ

Equipped with Automatic Air-speed Adjustment Equipped with High- /Low-ceiling Modes
In addition to the conventional 4-speed setting, units are now equipped Units are equipped with high- and low-ceiling operation modes that
with an automatic air-speed adjustment mode. This setting automati- make it possible to switch the airflow volume to match room height.
cally adjusts the air-speed to conditions that match the room environ- The ability to choose the optimum airflow volume makes it possible
ment. At the start of heating/cooling operation, the airflow is set to to optimize the breezy sensation felt throughout the room.
high-speed to quickly heat/cool the room. When the room tempera-
ture reaches the desired setting, the airflow speed is decreased auto- High Standard Low
Capacity
matically for stable comfortable heating/cooling operation. ceiling ceiling ceiling
35 3.5m 2.7m 2.5m
50 3.5m 2.7m 2.5m
Strong Gentle 60 3.5m 2.7m 2.5m
71 3.5m 2.7m 2.5m
100 4.2m 3.0m 2.6m
125 4.2m 3.0m 2.6m
Start of cooling/heating… After room temperature is stabilized… 140 4.2m 3.0m 2.6m

68

P049-080.indd 68 13.12.12 1:20:10 PM


PCA-RP71HAQ

PCA-HA
Standard features include a strong carbon-black stainless steel body and built-in
oil mist filter to prevent oil from getting into the unit providing a comfortable air
SERIES

conditioning environment in kitchens that use open-flame cooking.

Tough on Oily Smoke


A durable stainless steel casing that is resistant to oil and grease is provided to protect the surface of the body. Grimy dirt and stains are removed
easily, enabling the unit to be kept clean at all times.

High-performance Oil Mist Filter


A high-performance heavy-duty oil mist filter is included as standard equipment. The filtering system is more efficient than conventional filters,
thereby effectively reducing the oily smoke entering the air conditioner. The filter is disposable, thereby enabling trouble-free cleaning and mainte-
nance.

Oil Mist Filter Cleaning

When used in kitchens, the oil mist filter should be replaced


once every two months. The system comes with 12 filters
elements. After these have been used, optional elements
(PAC-SG38KF-E) can be purchased.
Oil mist filter Pull the handle to easily slide
the filter out

Easy Maintenance – Cosmetic Front and


Even for Cleaning the Fan Hanging Fixture Covers (Option)
A separate fan casing that can be Cosmetic covers are available to prevent the collection of dust and
disassembled in sections is ad- grime on the main body and hanging fixture sections.
opted to ensure easy fan clean-
ing. Drain pan cleaning onsite is
also no problem owing to the
use of a pipe connector that is Front cover Hanging fixture cover
easily removed.

Fresh Outside-air Intake (Option)


There is a knock-out opening on the rear panel of the unit that can
be used to bring fresh air into the unit. This helps to improve ventila-
tion and make the kitchen comfortable.

Flexible Duct
Knock-out opening (Procured locally)

Duct Flange
(ø200, Optional PAC-SF28OF-E)

Fresh air knock-out opening (ø200)

Fresh Air Knock-out Opening (ø200)

Notes: 1) A fresh-air duct flange is required (sold separately)


2) Intake air is not 100% fresh (outside) air.

69

P049-080.indd 69 13.12.12 1:20:11 PM


SERIES SELECTION
Power Inverter Series
Indoor Unit Outdoor Unit Remote Controller
For Single

PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100/125/140 Optional Optional Optional


35-71 100-250

Joint Lap Vector Sine Wave DC Scroll


35-140

For Multi
PCA-RP35/50/60/71/100/125/140KAQ
(Twin/Triple/Quadruple) DC Fan Motor Vector-Wave
35-71

Heat Caulking
Fixing Method
PUHZ-ZRP100/125/140 PUHZ-RP200/250 Grooved Piping

Standard Inverter Series


Indoor Unit Outdoor Unit Remote Controller
For Single

Optional Optional Optional


SUZ-KA35 SUZ-KA50/60/71 PUHZ-P100 PUHZ-P125/140
50-71 100-250 71-140

Joint Lap Vector Sine Wave DC Rotary


200/250 100-250 50-140

PCA-RP35/50/60/71/100/125/140KAQ For Multi


(Twin/Triple/Quadruple) DC Scroll DC Fan Motor Vector-Wave
50-71

Heat Caulking
Fixing Method
PUHZ-P100 PUHZ-P125/140/200/250 Grooved Piping

PCZ-RP KA Indoor Unit Combinations Indoor unit combinations shown below are possible.

Outdoor Unit Capacity


Indoor Unit Combination For Single For Twin For Triple For Quadruple
35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250
Power Inverter (PUHZ-ZRP/ RP) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – 35x2 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
Distribution Pipe – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E
Standard Inverter (PUHZ-P & SUZ) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – – 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
Distribution Pipe – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

SERIES SELECTION
Power Inverter Series
Indoor Unit Outdoor Unit Remote Controller

For Single

PUHZ-ZRP71 Optional Optional Optional


71 100-250

Joint Lap Vector Sine Wave DC Scroll


71

For Multi (Twin/Triple)


PCA-RP71HAQ DC Fan Motor Vector-Wave
71

Heat Caulking
Fixing Method
PUHZ-ZRP140 Grooved Piping

PUHZ-RP250

PCZ-RP HA Indoor Unit Combinations Indoor unit combinations shown below are possible.

Outdoor Unit Capacity


Indoor Unit Combination For Single For Twin For Triple For Quadruple
35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250
Power Inverter (PUHZ-ZRP/ RP) – – – 71x1 – – – – – – – – 71x2 – – – – 71x3 – –
Distribution Pipe – – – – – – – – – – – – MSDD-50TR-E – – – – MSDT-111R-E – –
Standard Inverter (PUHZ-P ) – – – – – – – – – – – – 71x2 – – – – 71x3 – –
Distribution Pipe – – – – – – – – – – – – MSDD-50TR-E – – – – MSDT-111R-E – –

70

P049-080.indd 70 13.12.12 1:20:14 PM


PCZ-RP KA SERIES
POWER INVERTER Optional Optional

60-140V/200/250

Please fill out the requested information


Please fill out the requested information

Optional Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PCA- PCA- PCA- PCA-
PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ
RP35KAQ RP50KAQ RP60KAQ RP71KAQ
Outdoor Unit PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
ZRP35VKA ZRP50VKA ZRP60VHA ZRP71VHA ZRP100VKA ZRP100YKA ZRP125VKA ZRP125YKA ZRP140VKA ZRP140YKA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 3.6 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Min - Max kW 1.6 - 4.5 2.3 - 5.6 2.7 - 6.7 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0 5.5 - 14.0 6.2 - 15.0 6.2 - 15.0
Total Input Rated kW 0.86 1.34 1.66 1.82 2.67 2.67 3.98 3.98 3.95 3.95
EER – – – – – – 3.14 3.14 3.39 3.39
EEL Rank – – – – – – – – – –
Design Load kW 3.6 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Annual Electricity Consumption*2 kWh/a 206 292 347 375 585 596 834 844 882 893
4 4 4
SEER 6.1 6.0 6.2 6.6 6.0 5.9 5.2* 5.2* 5.3* 5.2*4
Energy Efficiency Class A++ A+ A++ A++ A+ A+ – – – –
Heating Capacity Rated kW 4.1 5.5 7.0 8.0 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.6-5.2 2.5 - 6.6 2.8 - 8.2 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0
Season) Total Input Rated kW 1.02 1.45 1.93 2.20 3.04 3.04 3.80 3.80 4.57 4.57
COP – – – – – – 3.68 3.68 3.50 3.50
EEL Rank – – – – – – – – – –
Design Load kW 2.4 3.8 4.4 4.7 7.8 7.8 9.3 9.3 10.6 10.6
Declared Capacity at reference design temperature kW 2.4 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at bivalent temperature kW 2.4 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at operation limit temperature kW 2.2 (–11°C) 3.7 (–11°C) 2.8 (–20°C) 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0 0 0 0 0
Annual Electricity Consumption*2 kWh/a 815 1257 1458 1519 2837 2837 3097 3097 3366 3366
4 4 4
SCOP 4.1 4.2 4.3 4.3 3.9 3.9 4.2* 4.2* 4.4* 4.4*4
Energy Efficiency Class A+ A+ A+ A+ A A – – – –
Operating Current (max) A 13.3 13.4 19.4 19.4 27.2 8.7 27.3 10.3 28.9 11.9
Indoor Input Rated kW 0.04 0.05 0.06 0.06 0.09 0.09 0.11 0.11 0.14 0.14
Unit Operating Current (max) A 0.29 0.37 0.39 0.42 0.65 0.65 0.76 0.76 0.90 0.90
Dimensions <Panel> H × W × D mm 230 - 960 - 680 230 - 1280 - 680 230 - 1600 - 680
Weight <Panel> kg 24 25 32 32 36 36 38 38 39 39
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 10 - 11 - 12 - 14 10 - 11 - 13 - 15 15 - 16 - 17 - 19 16 - 17 - 18 - 20 22 - 24 - 26 - 28 22 - 24 - 26 - 28 23 - 25 - 27 - 29 23 - 25 - 27 - 29 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 31 - 33 - 36 - 39 32 - 34 - 37 - 40 33 - 35 - 37 - 40 35 - 37 - 39 - 41 37 - 39 - 41 - 43 37 - 39 - 41 - 43 39 - 41 - 43 - 45 39 - 41 - 43 - 45 41 - 43 - 45 - 48 41 - 43 - 45 - 48
Sound Level (PWL) dB(A) 60 60 60 62 63 63 65 65 68 68
Outdoor Dimensions H×W×D mm 630 - 809 - 300 943 - 950 - 330 (+30) 1338 - 1050 - 330 (+30)
Unit Weight kg 43 46 67 67 116 124 116 126 119 132
Air Volume Cooling m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Heating m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Sound Level (SPL) Cooling dB(A) 44 44 47 47 49 49 50 50 50 50
Heating dB(A) 46 46 48 48 51 51 52 52 52 52
Sound Level (PWL) Cooling dB(A) 65 65 67 67 69 69 70 70 70 70
Operating Current (max) A 13.0 13.0 19.0 19.0 26.5 8.0 26.5 9.5 28.0 11.0
Breaker Size A 16 16 25 25 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 75 75 75 75 75 75
Max. Height Out-In m 30 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –11 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.

PCZ-P KA SERIES
PUHZ PUHZ

STANDARD INVERTER Optional

PUHZ PUHZ SUZ


Optional

PUHZ PUHZ PUHZ

Please fill out the requested information


Please fill out the requested information

Optional Optional Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PCA-RP35KAQ PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ
Outdoor Unit SUZ-KA35VA4 SUZ-KA50VA4 SUZ-KA60VA4 SUZ-KA71VA4 PUHZ-P100VHA4 PUHZ-P100YHA2 PUHZ-P125VHA3 PUHZ-P125YHA PUHZ-P140VHA3 PUHZ-P140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VA4 • VHA4 • VHA3:230 / Single / 50, YHA2 • YHA:400 / Three / 50
Cooling Capacity Rated kW 3.6 5.0 5.7 7.1 9.4 9.4 12.3 12.3 13.6 13.6
Min - Max kW 1.4 - 3.9 2.3 - 5.6 2.3 - 6.3 2.8 - 8.1 4.9 - 11.2 4.9 - 11.2 5.5 - 14.0 5.5 - 14.0 5.5 - 15.0 5.5 - 15.0
Total Input Rated kW 1.050 1.550 1.720 2.060 3.130 3.130 4.090 4.090 4.840 4.840
EER – – – – – – 3.01 3.01 2.81 2.81
EEL Rank – – – – – – B B C C
Design Load kW 3.6 5.0 5.7 7.1 9.4 9.4 – – – –
Annual Electricity Consumption*2 kWh/a 214 307 332 414 645 645 – – – –
SEER 5.9 5.7 6.0 6.0 5.1 5.1 – – – –
Energy Efficiency Class A+ A+ A+ A+ A A – – – –
Heating Capacity Rated kW 4.1 5.5 6.9 7.9 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.7 - 5.0 1.7 - 6.6 2.5 - 8.0 2.6 - 10.2 4.5 - 12.5 4.5 - 12.5 5.0 - 16.0 5.0 - 16.0 5.0 - 18.0 5.0 - 18.0
Season) Total Input Rated kW 1.130 1.520 1.910 2.180 3.280 3.280 4.120 4.120 4.690 4.690
COP – – – – – – 3.40 3.40 3.41 3.41
EEL Rank – – – – – – C C B B
Design Load kW 2.6 4.0 4.8 5.8 8.0 8.0 – – – –
Declared Capacity at reference design temperature kW 2.3 (–10°C) 3.6 (–10°C) 4.3 (–10°C) 5.2 (–10°C) 6.3 (–10°C) 6.3 (–10°C) – – – –
at bivalent temperature kW 2.3 (–7°C) 3.6 (–7°C) 4.3 (–7°C) 5.2 (–7°C) 7.1 (–7°C) 7.1 (–7°C) – – – –
at operation limit temperature kW 2.3 (–10°C) 3.6 (–10°C) 4.3 (–10°C) 5.2 (–10°C) 5.0 (–15°C) 5.0 (–15°C) – – – –
Back Up Heating Capacity kW 0.3 0.4 0.5 0.6 1.7 1.7 – – – –
Annual Electricity Consumption*2 kWh/a 887 1398 1678 2028 2945 2945 – – – –
SCOP 4.1 4.0 4.0 4.0 3.8 3.8 – – – –
Energy Efficiency Class A+ A+ A+ A+ A A – – – –
Operating Current (max) A 8.5 12.4 14.4 16.5 28.7 13.7 28.8 13.8 30.4 13.9
Indoor Input Rated kW 0.04 0.05 0.06 0.06 0.09 0.09 0.11 0.11 0.14 0.14
Unit Operating Current (max) A 0.29 0.37 0.39 0.42 0.65 0.65 0.76 0.76 0.90 0.90
Dimensions <Panel> H × W × D mm 230 - 960 - 680 230 - 1280 - 680 230 - 1600 - 680
Weight <Panel> kg 24 25 32 32 36 36 38 38 39 39
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 10 - 11 - 12 - 14 10 - 11 - 13 - 15 15 - 16 - 17 - 19 16 - 17 - 18 - 20 22 - 24 - 26 - 28 22 - 24 - 26 - 28 23 - 25 - 27 - 29 23 - 25 - 27 - 29 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 31 - 33 - 36 - 39 32 - 34 - 37 - 40 33 - 35 - 37 - 40 35 - 37 - 39 - 41 37 - 39 - 41 - 43 37 - 39 - 41 - 43 39 - 41 - 43 - 45 39 - 41 - 43 - 45 41 - 43 - 45 - 48 41 - 43 - 45 - 48
Sound Level (PWL) dB(A) 60 60 60 62 63 63 65 65 68 68
Outdoor Dimensions H×W×D mm 550 - 800 - 285 880 - 840 - 330 943 - 950 - 330 (+30) 1350 - 950 - 330 (+30)
Unit Weight kg 35 54 50 53 75 77 99 101 99 101
Air Volume Cooling m3/min 36.3 44.6 40.9 50.1 60.0 60.0 100.0 100.0 100.0 100.0
Heating m3/min 34.8 44.6 49.2 48.2 60.0 60.0 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 49 52 55 55 50 50 51 51 52 52
Heating dB(A) 50 52 55 55 54 54 55 55 56 56
Sound Level (PWL) Cooling dB(A) 62 65 65 69 70 70 71 71 73 73
Operating Current (max) A 8.2 12.0 14.0 16.1 28.0 13.0 28.0 13.0 29.5 13.0
Breaker Size A 10 20 20 20 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 20 30 30 30 50 50 50 50 50 50
Max. Height Out-In m 12 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling °C –10 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3
[Outdoor] Heating °C –10 ~ +24 –10 ~ +24 –10 ~ +24 –10 ~ +24 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15~21 –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

71

P049-080.indd 71 13.12.12 1:20:17 PM


PCZ-RP HA SERIES
POWER INVERTER Optional Optional Optional Optional

Please fill out the requested information


Please fill out the requested information

Optional

Type Inverter Heat Pump


Indoor Unit PCA-RP71HAQ
Outdoor Unit PUHZ-ZRP71VHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50
Cooling Capacity Rated kW 7.1
Min - Max kW 3.3 - 8.1
Total Input Rated kW 2.17
EER –
EEL Rank –
Design Load kW 7.1
Annual Electricity Consumption*2 kWh/a 447
SEER 5.6
Energy Efficiency Class A+
Heating Capacity Rated kW 7.6
(Average Min - Max kW 3.5 - 10.2
Season) Total Input Rated kW 2.35
COP –
EEL Rank –
Design Load kW 4.7
Declared Capacity at reference design temperature kW 4.7 (–10°C)
at bivalent temperature kW 4.7 (–10°C)
at operation limit temperature kW 3.5 (–20°C)
Back Up Heating Capacity kW 0
Annual Electricity Consumption*2 kWh/a 1751
SCOP 3.8
Energy Efficiency Class A
Operating Current (max) A 19.4
Indoor Input Rated kW 0.09
Unit Operating Current (max) A 0.43
Dimensions <Panel> H × W × D mm 280 - 1136 - 650
Weight <Panel> kg 41
Air Volume [Lo-Hi] m3/min 17 - 19
Sound Level (SPL) [Lo-Hi] dB(A) 34 - 38
Sound Level (PWL) dB(A) 56
Outdoor Dimensions H×W×D mm 943 - 950 - 330 (+30)
Unit Weight kg 67
Air Volume Cooling m3/min 55.0
Heating m3/min 55.0
Sound Level (SPL) Cooling dB(A) 47
Heating dB(A) 48
Sound Level (PWL) Cooling dB(A) 67
Operating Current (max) A 19.0
Breaker Size A 25
Ext. Diameter Liquid / Gas mm 9.52 / 15.88
Piping Max. Length Out-In m 50
Max. Height Out-In m 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46
[Outdoor] Heating °C –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

72

P049-080.indd 72 13.12.12 1:20:18 PM


PSA SERIES
Installation of this floor-standing series is easy and quick.
An excellent choice when there is a sudden need for an air conditioner to be installed.

Quick and Easy Installation, Space-saving and


Design That Compliments Any Interior
The floor-standing indoor unit is mounted on the floor, enabling quick installation. Its compact body requires only minimal space.

● PSA-RP71KA
4-way pipe work connections enable greater freedom
in installation
Remarkable freedom in choosing installation sites is allowed
by providing piping connection to the indoor unit in four
places: left side, back, from underneath and on the right side
of the unit. Even installation in the corner of a room is easy.
1,900mm

Back
Left side

Right side

Underneath

600mm 360mm

Built-in Remote Controller


Easy Operation with Built-in PAR-21MAA Remote Controller
Icon, letter and number visibility are improved with the adoption of Main Functions
a dot liquid-crystal display (LCD), and operation management func-
tions have been increased. • Multi-language Display
• Limited Temperature Range Setting
• Auto-off Timer
• Operation Lock
• Weekly Timer

73

P049-080.indd 73 13.12.12 1:20:18 PM


SERIES SELECTION
Power Inverter Series
Indoor Unit Outdoor Unit

For Single

PUHZ-ZRP71 PUHZ-ZRP100/125/140

For Multi (Twin/Triple)

PSA-RP71/100/125/140KA
PUHZ-ZRP140 PUHZ-RP200/250

Remote Controller
71 100-250

Joint Lap Vector Sine Wave DC Scroll DC Fan Motor

71-140 71

Heat Caulking
Fixing Method
Vector-Wave Grooved Piping

Built-in

Standard Inverter Series


Indoor Unit Outdoor Unit

For Single

PUHZ-P100 PUHZ-P125/140

For Multi (Twin/Triple)

PSA-RP71/100/125/140KA
PUHZ-P140/200/250

Remote Controller
100-140 200/250

Vector Sine Wave DC Rotary DC Scroll DC Fan Motor

100-140

Vector-Wave Grooved Piping

Built-in

PSZ-RP KA Indoor Unit Combinations Indoor unit combinations shown below are possible.

Outdoor Unit Capacity

Indoor Unit Combination For Single For Twin For Triple For Quadruple

35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250

Power Inverter (PUHZ-ZRP / RP) – – – 71x1 100x1 125x1 140x1 – – – – – 71x2 100x2 125x2 – – 71x3 – –

Distribution Pipe – – – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E – – MSDT-111R-E – –

Standard Inverter (PUHZ-P ) – – – – 100x1 125x1 140x1 – – – – – 71x2 100x2 125x2 – – 71x3 – –

Distribution Pipe – – – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E – – MSDT-111R-E – –

74

P049-080.indd 74 13.12.12 1:20:20 PM


71-140V

PSZ-RP SERIES
POWER INVERTER Optional Optional Optional

Please fill out the requested information


Please fill out the requested information

Optional

Type Inverter Heat Pump


Indoor Unit PSA-RP71KA PSA-RP100KA PSA-RP125KA PSA-RP140KA
Outdoor Unit PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA PUHZ-ZRP125VKA PUHZ-ZRP125YKA PUHZ-ZRP140VKA PUHZ-ZRP140YKA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Min - Max kW 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0 5.5 - 14.0 6.2 - 15.0 6.2 - 15.0
Total Input Rated kW 1.89 2.75 2.75 4.09 4.09 4.06 4.06
EER – – – 3.06 3.06 3.30 3.30
EEL Rank – – – – – – –
Design Load kW 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Annual Electricity Consumption*2 kWh/a 396 629 640 847 885 872 883
SEER 6.3 5.6 5.5 5.0*4 4.9*4 5.3*4 5.3*4
Energy Efficiency Class A++ A+ A – – – –
Heating Capacity Rated kW 7.6 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0
Season) Total Input Rated kW 2.21 3.08 3.08 4.24 4.24 4.79 4.79
COP – – – 3.30 3.30 3.34 3.34
EEL Rank – – – – – – –
Design Load kW 4.7 7.8 7.8 9.3 9.3 10.6 10.6
Declared Capacity at reference design temperature kW 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at bivalent temperature kW 4.7 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at operation limit temperature kW 3.5 (–20°C) 5.8 (–20°C) 5.8 (–20°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0 0
Annual Electricity Consumption*2 kWh/a 1666 2761 2761 3285 3285 3331 3331
SCOP 4.0 4.0 4.0 4.0*4 4.0*4 4.4*4 4.4*4
Energy Efficiency Class A+ A+ A+ – – – –
Operating Current (max) A 19.4 27.2 8.7 27.2 10.2 28.7 11.7
Indoor Input Rated kW 0.06 0.11 0.11 0.11 0.11 0.11 0.11
Unit Operating Current (max) A 0.4 0.71 0.71 0.73 0.73 0.73 0.73
Dimensions <Panel> H × W × D mm 1900 - 600 - 360
Weight <Panel> kg 46 46 46 46 46 48 48
Air Volume [Lo-Mid-Hi] m3/min 20 - 22 - 24 25 - 28 - 30 25 - 28 - 30 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 40 - 42 - 44 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51
Sound Level (PWL) dB(A) 60 65 65 66 66 66 66
Outdoor Dimensions H×W×D mm 943 - 950 - 330 (+30) 1338-1050-330(+30)
Unit Weight kg 67 116 124 116 126 119 132
Air Volume Cooling m3/min 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Heating m3/min 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Sound Level (SPL) Cooling dB(A) 47 49 49 50 50 50 50
Heating dB(A) 48 51 51 52 52 52 52
Sound Level (PWL) Cooling dB(A) 67 69 69 70 70 70 70
Operating Current (max) A 19.0 26.5 8.0 26.5 9.5 28.0 11.0
Breaker Size A 25 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 75 75 75 75 75 75
Max. Height Out-In m 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.

PSZ-P SERIES
STANDARD INVERTER Optional Optional Optional Optional

Please fill out the requested information


Please fill out the requested information

Type Inverter Heat Pump


Indoor Unit PSA-RP100KA PSA-RP100KA PSA-RP125KA PSA-RP125KA PSA-RP140KA PSA-RP140KA
Outdoor Unit PUHZ-P100VHA4 PUHZ-P100YHA2 PUHZ-P125VHA3 PUHZ-P125YHA PUHZ-P140VHA3 PUHZ-P140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VHA4 • VHA3:230 / Single / 50, YHA2 • YHA:400 / Three / 50
Cooling Capacity Rated kW 9.4 9.4 12.3 12.3 13.6 13.6
Min - Max kW 4.9 - 11.2 4.9 - 11.2 5.5 - 14.0 5.5 - 14.0 5.5 - 15.0 5.5 - 15.0
Total Input Rated kW 3.120 3.120 4.380 4.380 5.640 5.640
EER – – 2.81 2.81 2.41 2.41
EEL Rank – – C C E E
Design Load kW 9.4 9.4 – – – –
Annual Electricity Consumption*2 kWh/a 716 716 – – – –
SEER 4.6 4.6 – – – –
Energy Efficiency Class B B – – – –
Heating Capacity Rated kW 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 4.5 - 12.5 4.5 - 12.5 5.0 - 16.0 5.0 - 16.0 5.0 - 18.0 5.0 - 18.0
Season) Total Input Rated kW 3.280 3.280 4.980 4.980 5.690 5.690
COP – – 2.81 2.81 2.81 2.81
EEL Rank – – D D D D
Design Load kW 8.0 8.0 – – – –
Declared Capacity at reference design temperature kW 6.3 (–10°C) 6.3 (–10°C) – – – –
at bivalent temperature kW 7.1 (–7°C) 7.1 (–7°C) – – – –
at operation limit temperature kW 5.0 (–15°C) 5.0 (–15°C) – – – –
Back Up Heating Capacity kW 1.7 1.7 – – – –
Annual Electricity Consumption*2 kWh/a 2945 2945 – – – –
SCOP 3.8 3.8 – – – –
Energy Efficiency Class A A – – – –
Operating Current (max) A 28.7 13.7 28.7 13.7 30.2 13.7
Indoor Input Rated kW 0.11 0.11 0.11 0.11 0.11 0.11
Unit Operating Current (max) A 0.71 0.71 0.73 0.73 0.73 0.73
Dimensions <Panel> H × W × D mm 1900 - 600 - 360
Weight <Panel> kg 46 46 46 46 48 48
Air Volume [Lo-Mid-Hi] m3/min 25 - 28 - 30 25 - 28 - 30 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31 25 - 28 - 31
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51 45 - 49 - 51
Sound Level (PWL) dB(A) 65 65 66 66 66 66
Outdoor Dimensions H×W×D mm 943 - 950 - 330 (+30) 1350 - 950 - 330 (+30)
Unit Weight kg 75 77 99 101 99 101
Air Volume Cooling m3/min 60.0 60.0 100.0 100.0 100.0 100.0
Heating m3/min 60.0 60.0 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 50 50 51 51 52 52
Heating dB(A) 54 54 55 55 56 56
Sound Level (PWL) Cooling dB(A) 70 70 71 71 73 73
Operating Current (max) A 28.0 13.0 28.0 13.0 29.5 13.0
Breaker Size A 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 50 50
Max. Height Out-In m 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

75

P049-080.indd 75 13.12.12 1:20:23 PM


PEAD-RP35/50/60/71/100/125/140JA(L)Q

PEAD SERIES
The thin, ceiling-concealed indoor units of this series are the perfect answer for the air
conditioning needs of buildings with minimum ceiling installation space and wide-
ranging external static pressure. Energy-saving efficiency has been improved, reduc-
ing electricity consumption and contributing to a further reduction in operating cost.

Compact Indoor Units


The height of the models from 35–140 has been unified to 250mm. Compared to the previous PEAD-RP EA model, the height has been reduced
by as much as 75mm (models 100–140), making installation in low ceilings with minimal clearance space possible.

Reduction of

250mm 75mm
(models 100 –140)
compared to PEAD-EA

PEAD-RP JA(L)Q

External Static Pressure


External static pressure conversion can be set up to five stages. Capable of being set to a maximum of 150Pa, units are applicable to a wide range
of building types.

■ External static pressure setting


Series 35 50 60 71 100 125 140
PEAD-RP EA 30/70Pa 70/130 (with optional motor) Pa
PEAD-RP GA – – 10/50/70Pa – –
PEAD-RP JA 35/50/70/100/150Pa

ErP Lot 10-compliant, Achieving High Energy Efficiency of SEER/SCOP Rank A+ and A++
A direct-current (DC) fan motor is installed in the indoor unit, increasing the seasonal energy efficiency of the newly designed Power Inverter Series
(PUHZ-ZRP) and resulting in compliance of the full-capacity models with ErP Lot 10 and energy rankings of A+/A++ for cooling and A/A+ for heating.
This contributes to an impressive reduction in the cost of annual electricity.

SEER SEER SEER SEER SEER SEER


A+ A+ A++ A+ A+ A+
SCOP SCOP SCOP SCOP SCOP SCOP
A+ A+ A+ A A+ A+
6.0 5.8 6.1 5.7 5.7 5.6
Minimum SEER 3.6
4.9 4.9
3.8 3.8 4.3 4.3
4.0 4.3 4.1 3.9 4.2 4.2 3.6 3.6
Minimum SCOP 3.4

Cooling PEAD-RP35JALQ PEAD-RP50JALQ PEAD-RP60JALQ PEAD-RP71JALQ PEAD-RP100JALQ PEAD-RP100JALQ PEAD-RP125JALQ PEAD-RP125JALQ PEAD-RP140JALQ PEAD-RP140JALQ
Heating PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP100YKA PUHZ-ZRP125VKA PUHZ-ZRP125YKA PUHZ-ZRP140VKA PUHZ-ZRP140YKA
✽ For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.

Drain Pump Option Available with All Models


The line-up consists of two types, models with or without a built-in drain pump.

PEAD-RP JAQ Drain pump built-in PEAD-RP JALQ No drain pump


✽ Units with an “L” included at the end of the model name are not equipped with a drain pump.

76

P049-080.indd 76 13.12.12 1:20:23 PM


SERIES SELECTION
Power Inverter Series
Indoor Unit Outdoor Unit

For Single

PUHZ-ZRP35/50 PUHZ-ZRP60/71 PUHZ-ZRP100/125/140

PEAD-RP35/50/60/71/100/125/140 For Multi


(Twin/Triple/Quadruple)

PUHZ-ZRP71 PUHZ-ZRP100/125/140 PUHZ-RP200/250

Remote Controller
35-71 100-250

Joint Lap Vector Sine Wave DC Scroll DC Fan Motor

35-140 35-71

Heat Caulking
Fixing Method
Vector-Wave Grooved Piping

Optional Optional Optional

Standard Inverter Series


Indoor Unit Outdoor Unit

For Single

SUZ-KA35 SUZ-KA50/60/71 PUHZ-P100 PUHZ-P125/140

PEAD-RP35/50/60/71/100/125/140
For Multi (Twin/Triple/Quadruple)

PUHZ-P100 PUHZ-P125/140/200/250

Remote Controller
35-71 100-250 71-140 200/250

Joint Lap Vector Sine Wave DC Rotary DC Scroll

100-250 35-140 35-71

Heat Caulking
Fixing Method
DC Fan Motor Vector-Wave Grooved Piping

Optional Optional Optional

PEAD-RP JA Indoor Unit Combinations Indoor unit combinations shown below are possible.

Outdoor Unit Capacity

Indoor Unit Combination For Single For Twin For Triple For Quadruple

35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250

Power Inverter (PUHZ-ZRP/ RP) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – 35x2 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4

Distribution Pipe – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

Standard Inverter (PUHZ-P & SUZ) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – – 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4

Distribution Pipe – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E

77

P049-080.indd 77 13.12.12 1:20:23 PM


60-140V/200/250 PUHZ

PEDZ-RP JA SERIES
POWER INVERTER Optional Optional Optional Optional

JAQ

Please fill out the requested information


Please fill out the requested information

Optional

Type Inverter Heat Pump


Indoor Unit PEAD- PEAD- PEAD- PEAD-
PEAD-RP100JA(L)Q PEAD-RP125JA(L)Q PEAD-RP140JA(L)Q
RP35JA(L)Q RP50JA(L)Q RP60JA(L)Q RP71JA(L)Q
Outdoor Unit PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
ZRP35VKA ZRP50VKA ZRP60VHA ZRP71VHA ZRP100VKA ZRP100YKA ZRP125VKA ZRP125YKA ZRP140VKA ZRP140YKA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VKA • VHA:230 / Single / 50, YKA:400 / Three / 50
Cooling Capacity Rated kW 3.6 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Min - Max kW 1.6 - 4.5 2.3 - 5.6 2.7 - 6.7 3.3 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0 5.5 - 14.0 6.2 - 15.3 6.2 - 15.3
Total Input Rated kW 0.89 (0.87) 1.44 (1.42) 1.65 (1.63) 2.01 (1.99) 2.63 (2.61) 2.63 (2.61) 4.05 (4.02) 4.05 (4.02) 4.36 (4.34) 4.36 (4.34)
EER*5 – – – – – – 3.09 (3.11) 3.09 (3.11) 3.07 (3.09) 3.07 (3.09)
EEL Rank – – – – – – – – – –
Design Load kW 3.6 5.0 6.1 7.1 10.0 10.0 12.5 12.5 13.4 13.4
Annual Electricity Consumption*2 kWh/a 228 (211) 317 (301) 366 (351) 446 (428) 624 (613) 634 (623) 907 (892) 918 (903) 1097 (1080) 1108 (1091)
4 4 4
SEER*5 5.6 (6.0) 5.5 (5.8) 5.8 (6.1) 5.6 (5.7) 5.6 (5.7) 5.5 (5.6) 4.8 (4.9)* 4.8 (4.9)* 4.3 (4.3)* 4.2 (4.3)*4
Energy Efficiency Class A+ (A+) A (A+) A+ (A++) A+ (A+) A+ (A+) A (A+) – – – –
Heating Capacity Rated kW 4.1 6.0 7.0 8.0 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.6 - 5.2 2.5 - 7.3 2.8 - 8.2 3.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0 5.0 - 16.0 5.7 - 18.0 5.7 - 18.0
Season) Total Input Rated kW 0.95 1.50 1.79 2.03 2.60 2.60 3.63 3.63 4.20 4.20
COP*5 – – – – – – 3.86 3.86 3.81 3.81
EEL Rank – – – – – – – – – –
Design Load kW 2.4 3.8 4.4 4.9 7.8 7.8 9.3 9.3 10.6 10.6
Declared Capacity at reference design temperature kW 2.4 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.9 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at bivalent temperature kW 2.4 (–10°C) 3.8 (–10°C) 4.4 (–10°C) 4.9 (–10°C) 7.8 (–10°C) 7.8 (–10°C) 9.3 (–10°C) 9.3 (–10°C) 10.6 (–10°C) 10.6 (–10°C)
at operation limit temperature kW 2.2 (–11°C) 3.7 (–11°C) 2.8 (–20°C) 3.7 (–20°C) 5.8 (–20°C) 5.8 (–20°C) 7.0 (–20°C) 7.0 (–20°C) 7.9 (–20°C) 7.9 (–20°C)
Back Up Heating Capacity kW 0 0 0 0 0 0 0 0 0 0
Annual Electricity Consumption*2 kWh/a 839 1231 1513 1762 2627 2627 3408 3408 4100 4100
SCOP*5 4.0 4.3 4.1 3.9 4.2 4.2 3.8*4 3.8*4 3.6*4 3.6*4
Energy Efficiency Class A+ A+ A+ A A+ A+ – – – –
Operating Current (max) A 14.1 14.4 20.6 21.0 29.2 10.7 29.3 12.3 30.8 13.8
Indoor Input [Cooling / Heating] Rated kW 0.09 (0.07) / 0.07 0.11(0.09) / 0.09 0.12 (0.10) / 0.10 0.17 (0.15) / 0.15 0.25 (0.23) / 0.23 0.25 (0.23) / 0.23 0.36 (0.34) / 0.34 0.36 (0.34) / 0.34 0.39 (0.37) / 0.37 0.39 (0.37) / 0.37
Unit Operating Current (max) A 1.07 1.39 1.62 1.97 2.65 2.65 2.76 2.76 2.78 2.78
Dimensions <Panel> H×W×D mm 250 - 900 - 732 250 - 1100 - 732 250 - 1400 - 732 250 - 1600 - 732
Weight <Panel> kg 26 (25) 28 (27) 33 (32) 33 (32) 41 (40) 41 (40) 43 (42) 43 (42) 47 (46) 47 (46)
Air Volume [Lo-Mid-Hi] m3/min 10.0 - 12.0 - 14.0 12.0 - 14.5 - 17.0 14.5 - 18.0 - 21.0 17.5 - 21.0 - 25.0 24.0 - 29.0 - 34.0 24.0 - 29.0 - 34.0 29.5 - 35.5 - 42.0 29.5 - 35.5 - 42.0 32.0 - 39.0 - 46.0 32.0 - 39.0 - 46.0
External Static Pressure Pa 35 / 50 / 70 / 100 / 150
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 23 - 27 - 30 26 - 31 - 35 25 - 29 - 33 26 - 30 - 34 29 - 34 - 38 29 - 34 - 38 33 - 36 - 40 33 - 36 - 40 34 - 38 - 43 34 - 38 - 43
Sound Level (PWL) dB(A) 52 57 55 57 61 61 63 63 66 66
Outdoor Dimensions H×W×D mm 630 - 809 - 300 943 - 950 - 330 (+30) 1338 - 1050 - 330 (+30)
Unit Weight kg 43 46 67 67 116 124 116 126 119 132
Air Volume Cooling m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Heating m3/min 45.0 45.0 55.0 55.0 110.0 110.0 120.0 120.0 120.0 120.0
Sound Level (SPL) Cooling dB(A) 44 44 47 47 49 49 50 50 50 50
Heating dB(A) 46 46 48 48 51 51 52 52 52 52
Sound Level (PWL) Cooling dB(A) 65 65 67 67 69 69 70 70 70 70
Operating Current (max) A 13.0 13.0 19.0 19.0 26.5 8.0 26.5 9.5 28.0 11.0
Breaker Size A 16 16 25 25 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 50 50 50 50 75 75 75 75 75 75
Max. Height Out-In m 30 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling*3 °C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating °C –11 ~ +21 –11 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21 –20 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
*5 EER/COP and SEER/SCOP for RP35~71 are measured at ESP 35Pa, for RP100 at ESP 37Pa, for RP125/140 at ESP 50Pa.

PEDZ-P JA SERIES
STANDARD INVERTER
PUHZ

Optional
PUHZ PUHZ

Optional Optional
PUHZ SUZ

Optional Optional
PUHZ

PUHZ JAQ PUHZ

Please fill out the requested information


Please fill out the requested information

Optional

Type Inverter Heat Pump


Indoor Unit PEAD- PEAD- PEAD- PEAD-
PEAD-RP100JA(L)Q PEAD-RP125JA(L)Q PEAD-RP140JA(L)Q
RP35JA(L)Q RP50JA(L)Q RP60JA(L)Q RP71JA(L)Q
Outdoor Unit PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
SUZ-KA35VA4 SUZ-KA50VA4 SUZ-KA60VA4 SUZ-KA71VA4
P100VHA4 P100YHA2 P125VHA3 P125YHA P140VHA3 P140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VA4 • VHA4 • VHA3:230 / Single / 50, YHA2 • YHA:400 / Three / 50
Cooling Capacity Rated kW 3.6 4.9 5.7 7.1 9.4 9.4 12.3 12.3 13.6 13.6
Min - Max kW 1.4 - 3.9 2.3 - 5.6 2.3 - 6.3 2.8 - 8.1 4.9 - 11.2 4.9 - 11.2 5.5 - 14.0 5.5 - 14.0 5.5 - 15.0 5.5 - 15.0
Total Input Rated kW 1.050 (1.030) 1.480 (1.460) 1.670 (1.650) 2.080 (2.060) 3.120 (3.102) 3.120 (3.102) 4.220 (4.200) 4.220 (4.200) 4.520 (4.500) 4.520 (4.500)
EER*4 – – – – – – 2.91 (2.93) 2.91 (2.93) 3.01 (3.02) 3.01 (3.02)
EEL Rank – – – – – – C C B B
Design Load kW 3.6 4.9 5.7 7.1 9.4 9.4 – – – –
Annual Electricity Consumption*2 kWh/a 229 (213) 318 (301) 356 (340) 429 (413) 716 (694) 716 (694) – – – –
SEER*4 5.5 (5.9) 5.4 (5.7) 5.6 (5.8) 5.8 (6.0) 4.6 (4.7) 4.6 (4.7) – – – –
Energy Efficiency Class A (A+) A (A+) A+ (A+) A+ (A+) B B – – – –
Heating Capacity Rated kW 4.1 5.9 7.0 8.0 11.2 11.2 14.0 14.0 16.0 16.0
(Average Min - Max kW 1.7 - 5.0 1.7 - 7.2 2.5 - 8.0 2.6 - 10.2 4.5 - 12.5 4.5 - 12.5 5.0 - 16.0 5.0 - 16.0 5.0 - 18.0 5.0 - 18.0
Season) Total Input Rated kW 1.110 1.620 1.930 2.040 3.103 3.103 3.870 3.870 4.430 4.430
COP*4 – – – – – – 3.62 3.62 3.61 3.61
EEL Rank – – – – – – A A A A
Design Load kW 2.8 4.4 4.5 6.0 8.0 8.0 – – – –
Declared Capacity at reference design temperature kW 2.5 (–10°C) 3.9 (–10°C) 4.0 (–10°C) 5.3 (–10°C) 6.3 (–10°C) 6.3 (–10°C) – – – –
at bivalent temperature kW 2.5 (–7°C) 3.9 (–7°C) 4.0 (–7°C) 5.3 (–7°C) 7.1 (–7°C) 7.1 (–7°C) – – – –
at operation limit temperature kW 2.5 (–10°C) 3.9 (–10°C) 4.0 (–10°C) 5.3 (–10°C) 5.0 (–15°C) 5.0 (–15°C) – – – –
Back Up Heating Capacity kW 0.3 0.5 0.5 0.7 1.7 1.7 – – – –
Annual Electricity Consumption*2 kWh/a 980 1466 1574 2153 2945 2945 – – – –
4
SCOP* 4.0 4.2 4.0 3.9 3.8 3.8 – – – –
Energy Efficiency Class A+ A+ A+ A A A – – – –
Operating Current (max) A 9.3 13.4 15.6 18.1 30.7 15.7 30.8 15.8 32.3 15.8
Indoor Input [Cooling / Heating] Rated kW 0.09(0.07) / 0.07 0.11(0.09)/0.09 0.12(0.10) /0.10 0.17(0.15) / 0.15 0.25(0.23)/0.23 0.25(0.23)/0.23 0.36(0.34)/0.34 0.36(0.34)/0.34 0.39(0.37)/0.37 0.39(0.37)/0.37
Unit Operating Current (max) A 1.07 1.39 1.62 1.97 2.65 2.65 2.76 2.76 2.78 2.78
Dimensions <Panel> H×W×D mm 250 - 900 - 732 250 - 1100 - 732 250 - 1400 - 732 250 - 1600 - 732
Weight <Panel> kg 26 (25) 28 (27) 33 (32) 33 (32) 41 (40) 41 (40) 43 (42) 43 (42) 47 (46) 47 (46)
3
Air Volume [Lo-Mid-Hi] m /min 10.0 - 12.0 - 14.0 12.0 - 14.5 - 17.0 14.5 - 18.0 - 21.0 17.5 - 21.0 - 25.0 24.0 - 29.0 - 34.0 24.0 - 29.0 - 34.0 29.5 - 35.5 - 42.0 29.5 - 35.5 - 42.0 32.0 - 39.0 - 46.0 32.0 - 39.0 - 46.0
External Static Pressure Pa 35 / 50 / 70 / 100 / 150
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 23 - 27 - 30 26 - 31 - 35 25 - 29 - 33 26 - 30 - 34 29 - 34 - 38 29 - 34 - 38 33 - 36 - 40 33 - 36 - 40 34 - 38 - 43 34 - 38 - 43
Sound Level (PWL) dB(A) 52 57 55 57 61 61 63 63 66 66
Outdoor Dimensions H×W×D mm 550 - 800 - 285 880 - 840 - 330 943 - 950 - 330(+30) 1350 - 950 - 330(+30)
Unit Weight kg 35 54 50 53 75 77 99 101 99 101
Air Volume Cooling m3/min 36.3 44.6 40.9 50.1 60.0 60.0 100.0 100.0 100.0 100.0
Heating m3/min 34.8 44.6 49.2 48.2 60.0 60.0 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 49 52 55 55 50 50 51 51 52 52
Heating dB(A) 50 52 55 55 54 54 55 55 56 56
Sound Level (PWL) Cooling dB(A) 62 65 65 69 70 70 71 71 73 73
Operating Current (max) A 8.2 12.0 14.0 16.1 28.0 13.0 28.0 13.0 29.5 13.0
Breaker Size A 16 20 20 20 32 16 32 16 40 16
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 20 30 30 30 50 50 50 50 50 50
Max. Height Out-In m 12 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range Cooling °C –10 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3 –15 ~ +46*3
[Outdoor] Heating °C –10 ~ +24 –10 ~ +24 –10 ~ +24 –10 ~ +24 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located. 78
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 EER/COP and SEER/SCOP for RP35~71 are measured at ESP 35Pa, for RP100 at ESP 37Pa, for RP125/140 at ESP 50Pa.

P049-080.indd 78 13.12.12 1:20:25 PM


PEA SERIES
For elegance and style, the PEA Series compliments the room environment with
an aesthetically pleasing ceiling installation and a vast line-up of performance
PEA-RP200/250/400/500GAQ

functions. Long pipe work installation is supported, increasing freedom in the


placement of indoor units.

Flexible Duct Design Enables Use


of High-pressure Static Fan Long Refrigerant Piping Length
A flexible duct design and 150Pa external static high-pressure are With the addition of more refrigerant, the maximum length for
incorporated. The increased variation in airflow options ensures refrigerant piping has been increased to 100 metres. As a result, it
operation that best is much easier to create the optimum layout for unit installation.
matches virtually all
Power Inverter Standard Inverter
room layouts. Connection Connection
Max. Length Max. Height Max. Length Max. Height
PEA-RP 200 100m 30m 70m 30m
250 100m 30m 70m 30m
400 100m 30m 70m 30m
500 100m 30m 70m 30m

Wide-ranging Line-up from 20–50kW – Extensive Array of Choices to Match Building Size
[System Image] • For PEA-200, 250 D
E F
PEA-RP200/250GAQ PUHZ-200, 250 1 2 PEA-200, 250
L1 L2 L3 N S1 S2 S3 S1 S2 S3 L1 L2 L3 N
A B C C B A

I
G I H G

• For PEA-400, 500 D


PEA-RP400/500GAQ E (No.1 Outdoor) F
PUHZ-200, 250 1 2 PEA-400, 500
(TB4-1) (TB4-2)
L1 L2 L3 N S1 S2 S3 S1 S2 S3 S1 S2 S3 L1 L2 L3 N
A B C C B A

G I H I
G A Power supply
B Earth leakage breaker
E (No.2 Outdoor)
C Circuit breaker or local switch
PUHZ-200, 250
D LCD remote controller
L1 L2 L3 N S1 S2 S3
A B C E Outdoor unit
F Indoor unit
G Power cable wiring

G I H H Indoor/Outdoor connection wiring


I Grounding
PAR-31MAA Group Control
The PAR-31MAA remote controller can control up to • For PEA-200, 250 E F G H
A Outdoor unit
A A A A B Indoor unit
16 systems* as a group, and is ideal for supporting the C Main remote controller
D Subordinate remote controller
integrated management of building air conditioners. E Standard (Refrigerant address = 00)
B B B B
2 2 2 F Refrigerant address = 01
*Count each set of PEA-RP400 and PEA-RP500 as two systems as G Refrigerant address = 02
1
two outdoor units are connected. C D
H Refrigerant address = 15
1

LINE-UP
Indoor Unit Outdoor Unit ✽ Two units are used when connecting PEA-RP400/500GAQ. Remote Controller

Power Standard
Inverter Inverter
Series Series

PEA-RP200/250/400/500GAQ PUHZ-RP200/250 PUHZ-P200/250 Optional Optional

79

P049-080.indd 79 13.12.12 1:20:27 PM


PEZ-RP SERIES
POWER INVERTER
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PEA-RP200GAQ PEA-RP250GAQ PEA-RP400GAQ PEA-RP500GAQ
Outdoor Unit PUHZ-RP200YKA PUHZ-RP250YKA PUHZ-RP200YKA x 2 PUHZ-RP250YKA x 2
Power Source Indoor / outdoor separate power supply
Supply Outdoor (V/Phase/Hz) 400 / Three / 50
Indoor (V/Phase/Hz) 400 / Three / 50
Cooling Capacity Rated kW 19.0 22.0 38.0 44.0
Min - Max kW 9.0 - 22.4 11.2 - 28.0 18.0 - 44.8 22.4 - 56.0
Total Input Rated kW 6.700 8.340 12.950 17.160
EER 2.84 2.64 2.93 2.56
EEL Rank – – – –
Heating Capacity Rated kW 22.4 27.0 44.8 54.0
Min - Max kW 9.5 - 25.0 12.5 - 31.5 18.0 - 50.0 25.0- 63.0
Total Input Rated kW 6.500 8.200 12.550 16.880
COP 3.45 3.29 3.57 3.20
EEL Rank – – – –
Operating Current (max) 21.0 23.3 41.8 47.4
Indoor Input Rated kW 1.000 1.180 1.550 2.840
Unit Operating Current (max) A 2.0 2.3 3.8 5.4
Dimensions HxWxD mm 400 - 1400 - 634 400 - 1600 - 634 595 - 1947 - 764
Weight kg 70 77 130 133
Air Volume [Lo-Hi] m3/min 52.0 - 65.0 64.0 - 80.0 120.0 160.0
External Static Pressure Pa 150 150 150 150
Sound Level [Lo-Hi] dB(A) 48 - 51 49 - 52 52*2 53*2
Breaker Size A 15 15 15 15
Outdoor Dimensions HxWxD mm 1338 - 1050 - 330(+30)
Unit Weight kg 135 141 135 141
Air Volume Cooling Rated m3/min 140.0 140.0 140.0 140.0
Heating Rated m3/min 140.0 140.0 140.0 140.0
Sound Level Cooling - Silent Rated dB(A) 58 - 55 58 - 55 58 - 55 58 - 55
Heating Rated dB(A) 59 59 59 59
Operating Current (max) A 19.0 21.0 19.0 21.0
Breaker Size A 32 32 32 32
Ext. Diameter Liquid / Gas mm 9.52 / 25.4 12.7 / 25.4 9.52 / 25.4 12.7 / 25.4
Piping Max. Length Out-In Total m 100 100 100 100
Max. Height Out-In m 30 30 30 30
o
Guaranteed Operating Range Cooling *1 C -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46
[Outdoor] Heating o
C -20 ~ +21 -20 ~ +21 -20 ~ +21 -20 ~ +21
*1 Optional air protection guide is required where ambient temperature is lower than -5°C. *2 Hi

PEZ-P SERIES
STANDARD INVERTER
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PEA-RP200GAQ PEA-RP250GAQ PEA-RP400GAQ PEA-RP500GAQ
Outdoor Unit PUHZ-P200YHA3 PUHZ-P250YHA3 PUHZ-P200YHA3 x 2 PUHZ-P250YHA3 x 2
Power Source Indoor / outdoor separate power supply
Supply Outdoor (V/Phase/Hz) 400 / Three / 50
Indoor (V/Phase/Hz) 400 / Three / 50
Cooling Capacity Rated kW 19.0 22.0 38.0 44.0
Min - Max kW 9.0 - 22.4 11.2 - 28.0 18.0 - 44.8 22.4 - 56.0
Total Input Rated kW 7.210 8.440 13.970 17.360
EER 2.64 2.61 2.72 2.53
EEL Rank – – – –
Heating Capacity Rated kW 22.4 27.0 44.8 54.0
Min - Max kW 9.5 - 25.0 12.5 - 31.5 19.0 - 50.0 25.0- 63.0
Total Input Rated kW 7.360 8.470 14.270 17.420
COP 3.04 3.19 3.14 3.10
EEL Rank – – – –
Operating Current (max) 21.0 23.3 41.8 47.4
Indoor Input Rated kW 1.000 1.180 1.550 2.840
Unit Operating Current (max) A 2.0 2.3 3.8 5.4
Dimensions HxWxD mm 400 - 1400 - 634 400 - 1600 - 634 500 - 1947 - 764 595 - 1947 - 764
Weight kg 70 77 130 133
Air Volume [Lo-Hi] m3/min 52.0 - 65.0 64.0 - 80.0 120.0 160.0
External Static Pressure Pa 150 150 150 150
Sound Level [Lo-Hi] dB(A) 48 - 51 49 - 52 52*2 53*2
Breaker Size A 15 15 15 15
Outdoor Dimensions HxWxD mm 1350 - 950 - 330(+30) 1338 - 1050 - 330(+30) 1350 - 950 - 330(+30)
Unit Weight kg 126 133 126 133
Air Volume Cooling Rated m3/min 130.0 130.0 130.0 130.0
Heating Rated m3/min 130.0 130.0 130.0 130.0
Sound Level Cooling - Silent Rated dB(A) 59 - 56 59 - 56 59 - 56 59 - 56
Heating Rated dB(A) 59 59 59 59
Operating Current (max) A 19.0 21.0 19.0 21.0
Breaker Size A 32 32 32 32
Ext. Diameter Liquid / Gas mm 9.52 / 25.4 12.7 / 25.4 9.52 / 25.4 12.7 / 25.4
Piping Max. Length Out-In Total m 70 70 70 70
Max. Height Out-In m 30 30 30 30
o
Guaranteed Operating Range Cooling*1 C -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46
[Outdoor] Heating o
C -11 ~ +21 -11 ~ +21 -11 ~ +21 -11 ~ +21
*1 Optional air protection guide is required where ambient temperature is lower than -5°C. *2 Hi

80

P049-080.indd 80 13.12.12 2:29:28 PM


POWERFUL
HEATINGSERIES

81

P081-092.indd 81 13.12.12 1:21:48 PM


SELECTION
Line-up consists of two series.
Choose the series that best matches the building layout.

ZUBADAN SERIES
The line-up includes outdoor unit models 7.1–12.5kW class and three types of indoor units.

Outdoor Unit Indoor Unit

4-way cassette

PLA Series
PUHZ-SHW80/112VHA
PUHZ-SHW112/140YHA

Ceiling-concealed Wall-mounted

PEAD Series PKA Series

MSZ-FH/MFZ-KJ VEHZ SERIES


The line-up includes outdoor models 25–50

Outdoor Unit Indoor Unit

Wall-mounted

MUZ-FH25/35VEHZ
MSZ-FH25 /35 /50VE
MUFZ-KJ25/35VEHZ

Floor-standing

MUZ-FH50VEHZ
MUFZ-KJ50VEHZ MFZ-KJ25/35/50VE

82

P081-092.indd 82 13.12.12 1:21:49 PM


ZUBADAN
The ZUBADAN Series incorporates an original Flash Injection technology that
improves the already high heating capacity of the system. This new member of
SERIES

the series line-up ensures comfortable heat pump-driven heating performance in


cold regions.
✽ Units in photo are Japanese models.
European model specifications are different.

Improved Heating Performance


Mitsubishi Electric’s unique “Flash Injection” circuit achieves remarkably high heating performance. This technology has resulted in an excellent
heating capacity rating in outdoor temperatures as low as -15°C, and the guaranteed heating operation range of the heating mode has been
extended to -25°C. Accordingly, the heat-pump units of the ZUBADAN Series are perfect for warming homes in the coldest of regions.

Guaranteed heating operation


Approx. 30% higher than model one size larger range is extended to -25°C
(example of 4HP model) ambient temperature

15 ZUBADAN 5HP
-11oC Power INV 3HP
capacity (kW)

ZUBADAN 4HP
P
10 INV 5H
Heating

Power -20oC Power INV 4&5HP


ZUBADAN 3HP
P
5 Power
INV 4H -25oC ZUBADAN 3-5HP

-25oC -20oC -15oC -7oC 0oC -25oC -20oC -15oC -10oC -5oC 0oC
Outdoor-air temperature at intake duct

Enhanced Comfort
The Flash Injection circuit improves start-up and recover from the defrosting operation. A newly introduced defrost operation control also improves
defrost frequency. These features enable the temperature to reach the set temperature more quickly, and contribute to maintaining it at the
desired setting.

Quick Start-up
■ Operation at +2°C outdoor temperature ■ Operation at -20°C outdoor temperature
Discharged air
temperature reaches 50oC
ZUBADAN rises quickly, (in stable condition) ZUBADAN rises quickly,
45°C in 10min Stable 45°C in 20min
15 15
13kW with 45°C indoor 13kW with 45°C indoor
19min 20min 30min
air outlet temperature 10min air outlet temperature

Normal INV: Normal INV:


capacity (kW)

capacity (kW)

10 10
45 oC in 19min 45 oC in 30min
Heating

Heating

Approx. 50% faster 33% faster


5 5

0 0
0 5 10 15 20 0 10 20 30
Operation time (min) Operation time (min)

ZUBADAN Defrost Control and Faster Recovery from Defrost Operation Field Test Results: Office building in Asahikawa, Hokkaido, Japan

■ Operation data for 25 Jan. 2005 ■ Operation data for 2 Dec. 2004
60 °C 60°C Indoor outlet temp.

50 °C Indoor outlet temp.


50°C

40 °C 40°C

30 °C 30°C
20 °C 20°C Room temp. Installation
Room temp.
10 °C example
10°C
Outdoor temp.
0 °C
18:00 20:00 22:00 0:00 2:00 4:00 6:00 0 °C
-10 °C
Outdoor temp. -10 °C
-20 °C 8:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00

-30 °C
ZUBADAN Defrost Control maintained a maximum interval
Reduced defrosting operation time
of 150 minutes between defrosting operations at outdoor
from 4 to 3 minutes.
temperatures of approximately -20°C and 0°C.

83

P081-092.indd 83 13.12.12 1:21:50 PM


ErP Lot 10 Compliant with High Energy-efficiency Achieving SEER/SCOP
Rank A and A+
Powerful heating yet annaully high energy efficiency in both cooling and heating, achieving rank A and A+.
SEER SEER SEER
A A SCOP A SCOP
SCOP
A A+ A+
Minimum SEER 3.6 5.1 5.5 5.5 5.1
Minimum SCOP 3.4 3.7 4.0 4.0 3.5

Cooling PLA-ZRP71BA PLA-ZRP100BA PLA-ZRP100BA PLA-ZRP125BA


Heating PUHZ-SHW80VHA PUHZ-SHW112VHA PUHZ-SHW112YHA PUHZ-SHW140YHA
✽ For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.

Mitsubishi Electric’s Flash Injection Technology


The Key to High Heating Performance at Low Outdoor Temperatures

■ Flash Injection Circuit

ZUBADAN Injection compressor


(injection port) Flash Injection Circuit

A
Indoor Outdoor
Power Heat Interchanger (HIC)
HEX HEX
receiver
B
LEV B LEV A

LEV C
A Heat B
interchanger Injection Compressor
Refrigerant (HIC)
flow Flash Injection Circuit

The Mr. Slim model of the ZUBADAN Series is equipped with Mitsubishi Electric’s Mollier Chart Image Representing Flash Injection
Circuit Operation
original Flash Injection Circuit, which is comprised of a bypass circuit and heat
interchanger (HIC). The HIC transforms rerouted liquid refrigerant into a gas-liquid
state to lower compression load. This process ensures excellent heating perfor-
mance even when the outdoor temperature drops very low.
LEV B
In traditional units, when the outdoor temperature is low, the volume of refrigerant
circulating in the compressor decreases due to the drop in refrigerant pressure LEV A LEV C
and protection from overheating due to high compression, thereby reducing heat-
ing capacity. The Flash Injection Circuit injects refrigerant to maintain the refriger-
ant circulation volume and compressor operation load, thereby maintaining heating
capacity.

A Heat Interchanger ( HIC ) B Injection Compressor

HIC cross-sectional view Injection


port Discharge port
Refrigerant passes through LEV C
(refrigerant pressure lowered)
Refrigerant doesn’t pass through LEV C Suction port

Purpose: Transform liquid refrigerant into


liquid-gas state
Effect: Injection circuit increases energy
efficiency Purpose: To increase the volume of refrigerant being circulated
Effect: Improves heating capacity at low outdoor tempera-
tures, and enables higher indoor-air outlet temperature
adjustment and higher defrost operation speed
The compressor is subjected to a heavy load when com-
pressing liquid refrigerant, and the result is lower operation
efficiency. The addition of HIC supports refrigerant heat ex- Refrigerant passes from the HIC into the compressor through
change at two different pressure levels. The heat-exchange the injection port. Having two refrigerant inlets makes it pos-
process transforms the injected liquid refrigerant into a gas sible to raise the volume of refrigerant being circulated when
liquid state, thereby decreasing the load on the compressor the outdoor temperature is low and at the start of heating
during the compression process. operation.

84

P081-092.indd 84 13.12.12 1:21:51 PM


Powerful

FH VEHZ
Core
for powerful
heating

SERIES
Unlike conventional air conditioning systems, the FH Series doesn’t lose heating
capacity when it’s cold outside. Original technologies ensure excellent heating
performance under extremely low outdoor temperatures and an impressive
guaranteed operating range.

Unparalleled Heating Performance


FH Series outdoor units are equipped with a high-output compressor that provides enhanced heating performance under low outdoor tempera-
tures. The heating operation range is extended down to -25°C.

Declared Capacity (at reference design temperature) Operation Range


6.0kW

-15 oC MSZ-SF
4.0kW
4.5kW
3.2kW
3.6kW -20 oC MSZ-EF VEH
3.0kW

-25 oC MSZ-FH VEHZ

MUZ- MUZ- MUZ- MUZ- MUZ- MUZ- -25oC -20oC -15oC -10oC -5oC 0oC
FH25VE FH25VEHZ FH35VE FH35VEHZ FH50VE FH50VEHZ

Compact, Powerful Compressor Compressor fixed using conventional Compressor fixed using Heat Caulking
method (Arc spot-welded method) Fixing Method
A special manufacturing technology,
“Heat Caulking Fixing Method,” has TNB175F
Downsized SNB172F
by 13%
been introduced to reduce compressor
size while maintaining a high compres-
sor output. This technology enables
the installation of a powerful compres-
sor in compact MUZ outdoor units. As
a result, excellent heating performance
Outer layer must be thick enough to hold the Compressor size reduced while maintaining
is achieved when operating in cold out- cylinder. same cylinder inner diameter.
door environments.

High Energy Efficiency – Energy Rank Freeze-prevention Heater Equipped


of A+ or higher for All Models as Standard
With indoor units that combine functionality, design and capacity The Freeze-prevention heater restricts lowered capacity and opera-
and outdoor units equipped with a high-efficiency compressor, the tion shutdowns caused by the drain water freezing. This supports
MUZ-FH VEHZ simultaneously achieves high heating capacity and stable operation in low-temperature environments.
energy-saving performance.

SEER SEER
Cooling Heating Operation Guaranteed at
9.1 8.9 Outside Temperature of –25°C
SEER
7.2
SCOP SCOP SCOP Frozen Drain does
4.9 4.8 4.2
SEER Rank A (5.1) drain not freeze
SCOP Rank A (3.4)

MUZ-FH25VEHZ MUZ-FH35VEHZ MUZ-FH50VEHZ Without Freeze-prevention heater With Freeze-prevention heater

85

P081-092.indd 85 13.12.12 1:21:51 PM


Indirect Airflow Direct Airflow
The indirect airflow setting can be used This setting can be used to directly target
when the flow of air feels too strong or airflow at people such as for immediate
The FH Series is equipped with 3D i-see Sensor, an infrared-ray direct. For example, it can be used during comfort when coming indoors on a hot
sensor that measures the temperature at distant positions. While cooling to avert airflow and prevent body (cold) day.
temperature from becoming excessively
moving to the left and right, eight vertically arranged sensor
cooled.
elements analyze the room temperature in three dimensions. This
detailed analysis makes it possible to judge where people are
in the room, thus allowing creation of features such as “Indirect
airflow,” to avoid airflow hitting people directly, and “direct airflow”
to deliver airflow to where people are.

Sensor with
eight elements
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode.

8 × 94 areas

Sensor measures while


moving to the left to right
Divided into 94
(Image) The “3D i-see Sensor” detects people’s absence and the power consumption is automatically
reduced approximately 10% after 10 minutes and 20% after 60 minutes.

Air, like water, is something we use everyday unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans. Achieving
this healthy air is Plasma Quad, a plasma-based filter system that effectively removes four kinds of air pollutants; namely, bacteria, viruses,
allergens and dust, which the air contains countless particles of.

Bacteria Viruses
Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad
neutralizes 99% of bacteria in 115 minutes in a neutralizes 99% of virus particles in 65
25m3 test space. minutes in a 25m3 test space.
Plasma Quad off Plasma Quad on Without Plasma Quad With Plasma Quad

<Test No.> KRCES-Bio.Test Report No.23_0317 * Hepatic cells turn transparent when affected by a virus.
<Test No.> vrc.center, SMC No.23-002

Effective deodorizing using


the air-purifying filter
Dust
In a test, air containing dust and ticks was
passed through the air cleaning device at the
low airflow setting. Before and after measure-
ments confirm that Plasma Quad removes
Allergens 88.6% of dust and ticks.
In a test, air containing cat fur and pollen was <Test No.> ITEA No.12M-RPTFEBO22
passed through the air cleaning device at the
low airflow setting. Before and after measure-
ments confirm that Plasma Quad neutralizes
94% of cat fur and 98% of pollen. (Image)
<Test No.> ITEA No.12M-RPTFEBO22

Principle of Plasma Quad


[ Effective Range ]
Plasma Quad attacks bacteria and viruses from inside the unit using a strong curtain-like
Macro Particulate size Nano electrical field and discharge of electric current across the whole inlet-air opening of the
unit. Tungsten discharge electrodes are used as they provide both discharge capacity and
strength. In addition, through flattening the standard, round form of the field to a ribbon-like
Dust Allergens Virus Bad Odours shape, a strong electrical field is produced.

Air Round:
Virus
Dust
Virus Bacteria
Pollen Bacteria Pet odours Fish odours

Mold spores Rubbish odours Plasma


space

Flattened: a strong electrical field is produced.

Plasma Quad Air-purifying filter Neutralization/inactivation

Air

86

P081-092.indd 86 13.12.12 1:21:55 PM


PLZ-SHW SERIES Please fill out the requested information
Please fill out the requested information

Indoor Unit Outdoor Unit Remote Controller

PUHZ-SHW80/112VHA Enclosed in
PLP-6BALM/PLP-6BALME
PUHZ-SHW112/140YHA
PLA-ZRP71/100/125BA

Standard Panel
PLP-6BA (only Panel)
PLP-6BALM (with wireless remote controller)
Automatic Filter Elevation Panel
PLP-6BAJ (only Panel)
Standard Panel with "i-see Sensor" *optional *optional
PLP-6BAE (only Panel)
PLP-6BALME (with wireless remote controller)

Optional Optional Optional

100/125

Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PLA-ZRP71BA PLA-ZRP100BA PLA-ZRP125BA
Outdoor Unit PUHZ-SHW80VHA PUHZ-SHW112VHA PUHZ-SHW112YHA PUHZ-SHW140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VHA:230 / Single / 50, YHA:400 / Three / 50
Cooling Capacity Rated kW 7.1 10.0 10.0 12.5
Min - Max kW 4.9 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0
Total Input Rated kW 1.864 2.786 2.786 4.449
EER – – – 2.81
EEL Rank – – – –
Design Load kW 7.1 10.0 10.0 12.5
Annual Electricity Consumption*2 kWh/a 484 633 633 856
SEER 5.1 5.5 5.5 5.1*4
Energy Efficiency Class A A A –
Heating Capacity Rated kW 8.0 11.2 11.2 14.0
(Average Min - Max kW 4.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0
Season)
Total Input Rated kW 2.047 2.667 2.667 3.879
COP – – – 3.61
EEL Rank – – – –
Design Load kW 9.1 12.7 12.7 15.8
Declared Capacity at reference design temperature kW 8.0 (–10°C) 11.2 (–10°C) 11.2 (–10°C) 14.0 (–10°C)
at bivalent temperature kW 8.0 (–7°C) 11.2 (–7°C) 11.2 (–7°C) 14.0 (–7°C)
at operation limit temperature kW 7.7 (–25°C) 9.4 (–25°C) 9.4 (–25°C) 9.5 (–25°C)
Back Up Heating Capacity kW 1.1 1.5 1.5 1.8
Annual Electricity Consumption*2 kWh/a 3389 4420 4420 6213
SCOP 3.7 4.0 4.0 3.5*4
Energy Efficiency Class A A+ A+ –
Operating Current (max) A 30.0 35.7 13.7 13.8
Indoor Input Rated kW 0.05 0.08 0.08 0.09
Unit Operating Current (max) A 0.45 0.74 0.74 0.80
Dimensions <Panel> H × W × D mm 298 - 840 - 840 <35 - 950 - 950>
Weight <Panel> kg 25 <6> 26 <6> 26 <6> 27 <6>
Air Volume [Lo-Mi2-Mi1-Hi] m3/min 17 - 19 - 21 - 23 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 28 - 30 - 34 - 36 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41
Sound Level (PWL) dB(A) 58 65 65 66
Outdoor Dimensions H×W×D mm 1350 - 950 - 330 (+30)
Unit Weight kg 120 120 134 134
Air Volume Cooling m3/min 100.0 100.0 100.0 100.0
3
Heating m /min 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 50 51 51 51
Heating dB(A) 51 52 52 52
Sound Level (PWL) Cooling dB(A) 68 69 69 69
Operating Current (max) A 29.5 35.0 13.0 13.0
Breaker Size A 32 40 16 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 75 75 75 75
Max. Height Out-In m 30 30 30 30
o
Guaranteed Operating Range Cooling*3 C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating o
C –25 ~ +21 –25 ~ +21 –25 ~ +21 –25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.
87 *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.

P081-092.indd 87 13.12.12 1:21:58 PM


PLZ-SHW SERIES
Indoor Unit Outdoor Unit Remote Controller

PUHZ-SHW80/112VHA Enclosed in
PLP-6BALM/PLP-6BALME
PUHZ-SHW112/140YHA
PLA-RP71/100/125BA

Standard Panel
PLP-6BA (only Panel)
PLP-6BALM (with wireless remote controller)
Automatic Filter Elevation Panel
PLP-6BAJ (only Panel)
Standard Panel with "i-see Sensor" *optional *optional
PLP-6BAE (only Panel)
PLP-6BALME (with wireless remote controller)

Optional Optional Optional

100/125

Optional Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit PLA-RP71BA PLA-RP100BA PLA-RP125BA
Outdoor Unit PUHZ-SHW80VHA PUHZ-SHW112VHA PUHZ-SHW112YHA PUHZ-SHW140YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VHA:230 / Single / 50, YHA:400 / Three / 50
Cooling Capacity Rated kW 7.1 10.0 10.0 12.5
Min - Max kW 4.9 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0
Total Input Rated kW 1.914 2.850 2.850 4.449
EER – – – 2.81
EEL Rank – – – –
Design Load kW 7.1 10.0 10.0 12.5
Annual Electricity Consumption*2 kWh/a 488 661 661 858
SEER 5.1 5.3 5.3 5.1*4
Energy Efficiency Class A A A –
Heating Capacity Rated kW 8.0 11.2 11.2 14.0
(Average Min - Max kW 4.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0
Season)
Total Input Rated kW 2.100 2.794 2.794 3.879
COP – – – 3.61
EEL Rank – – – –
Design Load kW 9.1 12.7 12.7 15.8
Declared Capacity at reference design temperature kW 8.0 (–10°C) 11.2 (–10°C) 11.2 (–10°C) 14.0 (–10°C)
at bivalent temperature kW 8.0 (–7°C) 11.2 (–7°C) 11.2 (–7°C) 14.0 (–7°C)
at operation limit temperature kW 7.7 (–25°C) 9.4 (–25°C) 9.4 (–25°C) 9.5 (–25°C)
Back Up Heating Capacity kW 1.1 1.5 1.5 1.8
Annual Electricity Consumption*2 kWh/a 3640 4445 4445 6506
SCOP 3.5 4.0 4.0 3.4*4
Energy Efficiency Class A A+ A+ –
Operating Current (max) A 30.0 35.9 13.9 14.0
Indoor Input Rated kW 0.07 0.14 0.14 0.15
Unit Operating Current (max) A 0.51 0.94 0.94 1.00
Dimensions <Panel> H × W × D mm 258 - 840 - 840 <35 - 950 - 950> 298 - 840 - 840 <35 - 950 - 950>
Weight <Panel> kg 23 <6> 25 <6> 25 <6> 25 <6>
3
Air Volume [Lo-Mi2-Mi1-Hi] m /min 14 - 16 - 18 - 21 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31
Sound Level (SPL) [Lo-Mi2-Mi1-Hi] dB(A) 28 - 30 - 32 - 34 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41
Sound Level (PWL) dB(A) 56 62 62 63
Outdoor Dimensions H×W×D mm 1350 - 950 - 330 (+30)
Unit Weight kg 120 120 134 134
Air Volume Cooling m3/min 100.0 100.0 100.0 100.0
3
Heating m /min 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 50 51 51 51
Heating dB(A) 51 52 52 52
Sound Level (PWL) Cooling dB(A) 68 69 69 69
Operating Current (max) A 29.5 35.0 13.0 13.0
Breaker Size A 32 40 16 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 75 75 75 75
Max. Height Out-In m 30 30 30 30
o
Guaranteed Operating Range Cooling*3 C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating o
C –25 ~ +21 –25 ~ +21 –25 ~ +21 –25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only. 88

P081-092.indd 88 13.12.12 1:21:59 PM


PKZ-SHW SERIES Please fill out the requested information
Please fill out the requested information

Indoor Unit Outdoor Unit Remote Controller

PKA-RP100KAL
PUHZ-SHW80/112VHA
PUHZ-SHW112/140YHA

*optional *optional

Optional Optional Optional Optional Optional Optional

Optional Optional

Type Inverter Heat Pump


Indoor Unit PKA-RP100KAL
Outdoor Unit PUHZ-SHW112VHA PUHZ-SHW112YHA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VHA:230 / Single / 50, YHA:400 / Three / 50
Cooling Capacity Rated kW 10.0 10.0
Min - Max kW 4.9 - 11.4 4.9 - 11.4
Total Input Rated kW 2.924 2.924
Design Load kW 10.0 10.0
2
Annual Electricity Consumption* kWh/a 673 673
SEER 5.2 5.2
Energy Efficiency Class A A
Heating Capacity Rated kW 11.2 11.2
(Average Min - Max kW 4.5 - 14.0 4.5 - 14.0
Season)
Total Input Rated kW 3.103 3.103
Design Load kW 12.7 12.7
Declared Capacity at reference design temperature kW 11.2 (–10°C) 11.2 (–10°C)
at bivalent temperature kW 11.2 (–7°C) 11.2 (–7°C)
at operation limit temperature kW 9.4 (–25°C) 9.4 (–25°C)
Back Up Heating Capacity kW 1.5 1.5
Annual Electricity Consumption*2 kWh/a 4664 4664
SCOP 3.8 3.8
Energy Efficiency Class A A
Operating Current (max) A 35.6 13.6
Indoor Input Rated kW 0.08 0.08
Unit Operating Current (max) A 0.57 0.57
Dimensions <Panel> H × W × D mm 365 - 1170 - 295
Weight <Panel> kg 21 21
Air Volume [Lo-Mid-Hi] m3/min 20 - 23 - 26 20 - 23 - 26
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 41 - 45 - 49 41 - 45 - 49
Sound Level (PWL) dB(A) 65 65
Outdoor Dimensions H×W×D mm 1350 - 950 - 330 (+30)
Unit Weight kg 120 134
Air Volume Cooling m3/min 100.0 100.0
3
Heating m /min 100.0 100.0
Sound Level (SPL) Cooling dB(A) 51 51
Heating dB(A) 52 52
Sound Level (PWL) Cooling dB(A) 69 69
Operating Current (max) A 35.0 13.0
Breaker Size A 40 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 75 75
Max. Height Out-In m 30 30
o
Guaranteed Operating Range Cooling*3 C –15 ~ +46 –15 ~ +46
[Outdoor] Heating o
C –25 ~ +21 –25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.

89

P081-092.indd 89 13.12.12 1:22:00 PM


PEDZ-SHW JA SERIES Please fill out the requested information
Please fill out the requested information

Indoor Unit Outdoor Unit Remote Controller

PUHZ-SHW80/112VHA *optional
PEAD-RP71/100/125JA(L)Q PUHZ-SHW112/140YHA

*optional *optional

100/125

Optional Optional Optional Optional

JAQ

Optional

Type Inverter Heat Pump


Indoor Unit PEAD-RP71JA(L)Q PEAD-RP100JA(L)Q PEAD-RP125JA(L)Q
Outdoor Unit PUHZ-SHW80VHA PUHZ-SHW112VHA PUHZ-SHW112YHA PUHZ-SHW140YHA
1
Refrigerant R410A*
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) VHA:230 / Single / 50, YHA:400 / Three / 50
Cooling Capacity Rated kW 7.1 10.0 10.0 12.5
Min - Max kW 4.9 - 8.1 4.9 - 11.4 4.9 - 11.4 5.5 - 14.0
Total Input Rated kW 1.899 (1.879) 2.924 (2.904) 2.924 (2.904) 3.895 (3.875)
EER – – – 3.21 (3.22)
EEL Rank – – – –
Design Load kW 7.1 10.0 10.0 12.5
Annual Electricity Consumption*2 kWh/a 540 (529) 729 (714) 729 (714) 906 (892)
SEER 4.6 (4.7) 4.8 (4.9) 4.8 (4.9) 4.8 (4.9)*4
Energy Efficiency Class B B B –
Heating Capacity Rated kW 8.0 11.2 11.2 14.0
(Average Min - Max kW 4.5 - 10.2 4.5 - 14.0 4.5 - 14.0 5.0 - 16.0
Season)
Total Input Rated kW 2.217 3.103 3.103 3.879
COP – – – 3.61
EEL Rank – – – –
Design Load kW 9.1 12.7 12.7 15.8
Declared Capacity at reference design temperature kW 8.0 (–10°C) 11.2 (–10°C) 11.2 (–10°C) 14.0 (–10°C)
at bivalent temperature kW 8.0 (–7°C) 11.2 (–7°C) 11.2 (–7°C) 14.0 (–7°C)
at operation limit temperature kW 7.7 (–25°C) 9.4 (–25°C) 9.4 (–25°C) 9.5 (–25°C)
Back Up Heating Capacity kW 1.1 1.5 1.5 1.8
2
Annual Electricity Consumption* kWh/a 3421 4664 4664 6072
SCOP 3.7 3.8 3.8 3.6*4
Energy Efficiency Class A A A –
Operating Current (max) A 31.5 37.7 15.7 15.8
Indoor Input [Cooling / Heating] Rated kW 0.17 (0.15) / 0.15 0.25 (0.23) / 0.23 0.25 (0.23) / 0.23 0.36 (0.34) / 0.34
Unit Operating Current (max) A 1.97 2.65 2.65 2.76
Dimensions H×W×D mm 250 - 1100 - 732 250 - 1400 - 732
Weight kg 33 (32) 41 (40) 41 (40) 43
Air Volume [Lo-Mid-Hi] m3/min 17.5 - 21.0 - 25.0 24.0 - 29.0 - 34.0 24.0 - 29.0 - 34.0 29.5 - 35.5 - 42.0
External Static Pressure Pa 35 / 50 / 70 / 100 / 150 35 / 50 / 70 / 100 / 150 35 / 50 / 70 / 100 / 150 35 / 50 / 70 / 100 / 150
Sound Level (SPL) [Lo-Mid-Hi] dB(A) 26 - 30 - 34 29 - 34 - 38 29 - 34 - 38 33 - 36 - 40
Sound Level (PWL) dB(A) 57 61 61 63
Outdoor Dimensions H×W×D mm 1350 - 950 - 330 (+30)
Unit Weight kg 120 120 134 134
Air Volume Cooling m3/min 100.0 100.0 100.0 100.0
Heating m3/min 100.0 100.0 100.0 100.0
Sound Level (SPL) Cooling dB(A) 50 51 51 51
Heating dB(A) 51 52 52 52
Sound Level (PWL) Cooling dB(A) 68 69 69 69
Operating Current (max) A 29.5 35.0 13.0 13.0
Breaker Size A 32 40 16 16
Ext. Diameter Liquid / Gas mm 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Piping Max. Length Out-In m 75 75 75 75
Max. Height Out-In m 30 30 30 30
o
Guaranteed Operating Range Cooling*3 C –15 ~ +46 –15 ~ +46 –15 ~ +46 –15 ~ +46
[Outdoor] Heating o
C –25 ~ +21 –25 ~ +21 –25 ~ +21 –25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
90

P081-092.indd 90 13.12.12 1:22:01 PM


25-35 25-35

SEER SCOP
MSZ-FH VEHZ SERIES Please fill out the requested information
Please fill out the requested information
A +++
A++

Indoor Unit Outdoor Unit Remote Controller

MUZ-FH25/35VEHZ MUZ-FH50VEHZ
MSZ-FH25/35/50VE White

Weekly
HUMAN Natural Flow Timer
VERTICAL HORIZONTAL 24-hour Timer

Wi-Fi
Interface
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE
Outdoor Unit MUZ-FH25VEHZ MUZ-FH35VEHZ MUZ-FH50VEHZ
Refrigerant R410A (*1)
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50
Cooling Design Load kW 2.5 3.5 5.0
Annual Electricity Consumption (*2) kWh/a 96 138 244
( 4)
SEER * 9.1 8.9 7.2
Energy Efficiency Class A+++ A+++ A++
Capacity Rated kW 2.5 3.5 5.0
Min - Max kW 0.8 - 3.5 0.8 - 4.0 1.9 - 6.0
Total Input Rated kW 0.485 0.820 1.380
Heating Design Load kW 3.2 (–10°C) 4.0 (–10°C) 6.0 (–10°C)
(Average Declared Capacity at reference design temperature kW 3.2 (–10°C) 4.0 (–10°C) 6.0 (–10°C)
Season)(*5)
at bivalent temperature kW 3.2 (–10°C) 4.0 (–10°C) 6.0 (–10°C)
at operation limit temperature kW 1.7 (–25°C) 2.6 (–25°C) 3.8 (–25°C)
Back Up Heating Capacity kW 0.0 (–10°C) 0.0 (–10°C) 0.0 (–10°C)
Annual Electricity Consumption (*2) kWh/a 924 1173 2006
SCOP (*4) 4.9 4.8 4.2
Energy Efficiency Class A++ A++ A+
Capacity Rated kW 3.2 4.0 6.0
Min - Max kW 1.0 - 6.3 1.0 - 6.6 1.7 - 8.7
Total Input Rated kW 0.580 0.800 1.480
Operating Current (max) A 9.6 10.5 14.0
Indoor Input Rated kW 0.029 0.029 0.031
Unit Operating Current (max) A 0.4 0.4 0.4
Dimensions H×W×D mm 305 (+17) - 925 - 234
Weight kg 13.5 13.5 13.5
Air Volume Cooling m3/min 3.9 - 4.7 - 6.3 - 8.6 - 11.6 (10.5) 3.9 - 4.7 - 6.3 - 8.6 - 11.6 (10.5) 6.4 - 7.4 - 8.6 - 10.1 - 12.4
(SLo-Lo-Mid-Hi-SHi (*3) (Dry/Wet)) Heating m /min3
4.0 - 4.7 - 6.4 - 9.2 - 13.2 4.0 - 4.7 - 6.4 - 9.2 - 13.2 5.7 - 7.2 - 9.0 - 11.2 - 14.6
Sound Level (SPL) Cooling dB(A) 20 - 23 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 27 - 31 - 35 - 39 - 44
(SLo-Lo-Mid-Hi-SHi (*3)) Heating dB(A) 20 - 24 - 29 - 36 - 44 21 - 24 - 29 - 36 - 44 25 - 29 - 34 - 39 - 46
Sound Level (PWL) dB(A) 58 58 60
Outdoor Dimensions H×W×D mm 550 - 800 - 285 880 - 840 - 330
Unit Weight kg 37 37 55
Air Volume Cooling m3/min 31.3 33.6 48.8
3
Heating m /min 31.3 33.6 51.3
Sound Level (SPL) Cooling dB(A) 46 49 51
Heating dB(A) 49 50 54
Sound Level (PWL) Cooling dB(A) 60 61 64
Operating Current (max) A 9.2 10.1 13.6
Breaker Size A 10 12 16
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7
Piping Max. Length Out-In m 20 20 30
Max. Height Out-In m 12 12 15
o
Guaranteed Operating Range Cooling C –10 ~ +46 –10 ~ +46 –10 ~ +46
[Outdoor] Heating o
C –25 ~ +24 –25 ~ +24 –25 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifications.

91

P081-092.indd 91 13.12.12 1:22:02 PM


25

SEER SCOP
MFZ-KJ SERIES Please fill out the requested information
Please fill out the requested information
A +++
A+

Indoor Unit Outdoor Unit Remote Controller

MUFZ-KJ25/35VEHZ

MFZ-KJ25/35/50VE

MUFZ-KJ50VEHZ

Nano
Platinum
Optional Optional Optional

Type Inverter Heat Pump


Indoor Unit MFZ-KJ25VE MFZ-KJ35VE MFZ-KJ50VE
Outdoor Unit MUFZ-KJ25VEHZ MUFZ-KJ35VEHZ MUFZ-KJ50VEHZ
Refrigerant R410A (*1)
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50
Cooling Design Load kW 2.5 3.5 5.0
Annual Electricity Consumption (*2) kWh/a 102 150 266
( 4)
SEER * 8.5 8.1 6.5
Energy Efficiency Class A+++ A++ A++
Capacity Rated kW 2.5 3.5 5.0
Min - Max kW 0.5 - 3.4 0.5 - 3.7 1.6 - 5.7
Total Input Rated kW 0.540 0.940 1.410
Heating Design Load kW o
3.5 (–10 C)
o
3.6 (–10 C)
o
4.5 (–10 C)
(Average Declared Capacity at reference design temperature kW o
3.5 (–10 C)
o
3.6 (–10 C)
o
4.5 (–10 C)
Season) o o o
at bivalent temperature kW 3.5 (–10 C) 3.6 (–10 C) 4.5 (–10 C)
at operation limit temperature kW o
1.6 (–25 C)
o
2.3 (–25 C)
o
3.3 (–25 C)
Back Up Heating Capacity kW o
0.0 (–10 C)
o
0.0 (–10 C)
o
0.0 (–10 C)
Annual Electricity Consumption (*2) kWh/a 1104 1158 1467
SCOP (*4) 4.4 4.3 4.2
Energy Efficiency Class A+ A+ A+
Capacity Rated kW 3.4 4.3 6.0
Min - Max kW 1.2 - 5.1 1.2 - 5.8 2.2 - 8.4
Total Input Rated kW 0.770 1.100 1.610
Operating Current (max) A 4.42 3.91 3.73
Indoor Input Rated kW 0.016 0.016 0.038
Unit Operating Current (max) A 0.17 0.17 0.34
Dimensions H×W×D mm 600 - 750 - 215
Weight kg 15 15 15
Air Volume Cooling m3/min 3.9 - 4.9 - 5.9 - 7.1 - 8.2 3.9 - 4.9 - 5.9 - 7.1 - 8.2 5.6 - 6.7 - 8.0 - 9.3 - 10.6
(SLo-Lo-Mid-Hi-SHi (*3) (Dry/Wet)) Heating 3
m /min 3.9 - 5.1 - 6.2 - 7.7 - 9.7 3.9 - 5.1 - 6.2 - 7.7 - 9.7 6.0 - 7.4 - 9.4 - 11.6 - 14.0
Sound Level (SPL) Cooling dB(A) 20 - 25 - 30 - 35 - 39 20 - 25 - 30 - 35 - 39 27 - 31 - 35 - 39 - 44
(SLo-Lo-Mid-Hi-SHi (*3)) Heating dB(A) 19 - 25 - 30 - 35 - 41 19 - 25 - 30 - 35 - 41 29 - 35 - 40 - 45 - 50
Sound Level (PWL) dB(A) 49 50 56
Outdoor Dimensions H×W×D mm 550 - 800 - 285 880 - 840 - 330
Unit Weight kg 37 37 55
Air Volume Cooling m3/min 31.3 31.3 45.8
3
Heating m /min 33.6 33.6 45.8
Sound Level (SPL) Cooling dB(A) 46 47 49
Heating dB(A) 51 51 51
Sound Level (PWL) Cooling dB(A) 59 60 63
Operating Current (max) A 9.2 10 13.6
Breaker Size A 10 12 16
Ext. Diameter Liquid / Gas mm 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7
Piping Max. Length Out-In m 20 20 30
Max. Height Out-In m 12 12 15
o
Guaranteed Operating Range Cooling C –10 ~ +46 –10 ~ +46 –10 ~ +46
[Outdoor] Heating o
C –25 ~ +24 –25 ~ +24 –25 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.

92

P081-092.indd 92 13.12.12 1:22:03 PM


MXZ SERIES

93

P093-98.indd 93 13.12.12 1:23:03 PM


SELECTION
Choose from five types of indoor units and fourteen outdoor units that can run up to eight indoor units each.
Create the system that best matches room shapes and number of rooms.

STEP 1 SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted Floor-standing Cassette Ceiling-suspended

MSZ-FH

PCA

MSZ-EF
SLZ Ceiling-concealed

MLZ
MSZ-SF (15 • 20)
MFZ-KJ

SEZ
MSZ-SF (25-50) PLA

MSZ-GF PEAD

STEP 2 SELECT OUTDOOR UNITS


Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port 3-port 4-port 8-port Connect up to 8 indoor units


Connect up to 2 indoor units Connect up to 3 indoor units Connect up to 4 indoor units

Outdoor Unit Branch Box

MXZ-2D33VA PAC-AK32BC
MXZ-3D54VA2
MXZ-2D42VA MXZ-4D72VA MXZ-4D83VA
MXZ-3D68VA
MXZ-2D53VA(H)

5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units

PAC-AK53BC

MXZ-8B140V(Y)A
MXZ-8B160V(Y)A

Connection to indoor units requires an appropriate


branch box (distribution piping is required when
connecting two branch boxes).
MXZ-5D102VA MXZ-6C122VA

STEP 3 CHECK SYSTEM COMPATIBILITY


Possible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected
Combination is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

94

P093-98.indd 94 13.12.12 1:23:05 PM


MXZ
Outdoor
Unit

SERIES
Advancements in the MXZ Series include efficiency and flexibility in system
expansion capabilities. The best solution when requiring multi-system air
conditioning needs.

8-port 6-port 4-port 5-port 3-port 4-port 2-port

MXZ-8B140VA Single Phase MXZ-6C122VA MXZ-4D83VA MXZ-3D54VA2 MXZ-2D33VA


MXZ-8B140YA Three Phase MXZ-5D102VA MXZ-3D68VA MXZ-2D42VA
MXZ-8B160VA Single Phase MXZ-4D72VA MXZ-2D53VA (H)
MXZ-8B160YA Three Phase

EXAMPLE SYSTEM
Smaller MXZ 2, 3, 4, 5 and 6 ports
(example of MXZ-6C122VA system) Power Multi MXZ-8B160VA
MSZ-EF MSZ-FH

MSZ-EF
MSZ-SF MSZ-SF

MSZ-FH PAC-AK32BC
PLA-BA
PAC-AK53BC
MFZ-KJ
MFZ-KJ
SLZ-KA

MLZ-KA MSDD-50AR-E SEZ-KD


or
MSDD-50BR-E
MLZ-KA MXZ-8B160VA
SLZ-KA

MXZ-6C122VA

Handle Up to 8 Rooms with a Single Outdoor Unit


The MXZ Series offers a fourteen-system line-up to choose from, ranging between 3.3 and 15.5kW. All of them are compatible with specific
M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

Support Functions
Wiring/Piping Correction Function* (3D54/3D68/4D72/4D83/5D102/6C122)
Simply press a single button to confirm if wiring and piping are prop- Wiring
confirmation The outdoor unit
erly connected. Wiring errors are corrected automatically when dis- is time matches
consuming. pipes and wiring.
covered. This eliminates the need to confirm complicated wiring
connections when expanding the system. (For details, refer to the
outdoor unit installation manual.)
* Function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10 –20 minutes to complete and must be conducted
with the unit set to the “Cooling” mode.

Automatic Line Correcting Ampere Limit Adjustment


(MXZ-2D33VA/2D42VA/2D53VA(H)/3D54VA2) (4D83/5D102/6C122/8B140/8B160)

Improper wiring or piping can be automatically detected when one Dipswitch settings can be used to adjust the maximum electrical
indoor unit is operated in COOL mode for 30 minutes. When improper current for operation. This function is highly recommended for man-
wiring or piping is detected, wiring lines are corrected (A to B/B to A) aging energy costs. (For details, refer to the outdoor unit installation
with the software. manual.)
* This function may not work due to the condition or environment of the unit, such as * Maximum capacity is lowered with the use of this function.
the following:
- gas leak, closed stop valve
- unit failure such as defective LEV
Operation Lock
- indoor/outdoor temperature
* This function does not work when the “2” of SW2 on the outdoor display To accommodate specific use applications, cooling or heating opera-
P.C. board is turned OFF. tion can be specified when setting the control board of the outdoor
unit. A convenient option when a system needs to be configured for
exclusive cooling or heating service. (For details, refer to the outdoor
unit installation manual.)
95

P093-98.indd 95 13.12.12 1:23:07 PM


MXZ SERIES
INVERTER MULTI 2D-4D72 8B 4D83-6C 8B 8B 3D-5D

Please fill out the requested information


Please fill out the requested information

Type (Inverter Multi - Split Heat Pump) Up to 2 Indoor Units Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units
Indoor Unit Please refer to (*5)
Outdoor Unit MXZ-2D33VA MXZ-2D42VA MXZ-2D53VA MXZ-2D53VAH MSZ-3D54VA2 MXZ-3D68VA MXZ-4D72VA MXZ-4D83VA MXZ-5D102VA
Refrigerant R410A*1
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 230 / Single / 50
Cooling Capacity Rated kW 3.3 4.2 5.3 5.3 5.4 6.8 7.2 8.3 10.2
Input (Indoor+Outdoor) Rated kW 0.90 1.54 1.54 2.19 2.25 2.83 3.91
Design Load kW 3.3 4.2 5.3 5.3 5.4 6.8 7.2 8.3 10.2
2
Annual Electricity Consumption* kWh/a 211 262 262 425 443 560 678
5
SEER* 5.5 7.1 7.1 5.6 5.7 5.2 5.3
Energy Efficiency Class* 5
A A++ A++ A+ A+ A A
Heating Capacity Rated kW 4.0 4.5 6.4 6.4 7.0 8.6 8.6 9.0 10.5
(Average Input (Indoor+Outdoor) Rated kW 0.96 1.70 1.70 2.38 2.28 2.42 2.90
Season)
Design Load kW 2.7 4.5 4.5 6.8 7.0 7.1 8.6
Declared at reference design temperature kW 2.1 3.7 3.6 5.4 5.6 5.6 6.9
Capacity at bivalent temperature kW 2.4 4.0 4.0 6.0 6.2 6.2 7.6
at operation limit temperature kW 1.7 3.3 3.0 4.4 4.7 4.7 5.6
Back Up Heating Capacity kW 0.6 0.8 0.9 1.4 1.4 1.5 1.7
2
Annual Electricity Consumption* kWh/a 926 1507 1546 2466 2516 2536 3184
SCOP*5 4.1 4.2 4.1 3.9 3.9 3.9 3.8
Energy Efficiency Class*5 A+ A+ A+ A A A A
Max. Operating Current (Indoor+Outdoor) A 10.0 12.2 12.2 18.0 18.0 20.4 21.4
Outdoor Dimensions H×W×D mm 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 915 - 900 - 320 (+67)
Unit Weight kg 32 37 37 38 57 57 58 69 70
Air Volume Cooling m3/min 32.9 32.9 32.9 42.1 42.1 42.1 56.6
Heating m3/min 33.7 33.3 33.3 43.0 43.0 43.8 59.3
Sound Level (SPL) Cooling dB(A) 49 50 50 50 50 49 53
Heating dB(A) 50 53 53 53 53 50 55
Sound Level (PWL) Cooling dB(A) 63 64 64 64 64 64 68
Breaker Size A 10 15 15 15 25 25 25 25 25
Ext. Diameter Liquid mm 6.35 × 2 6.35 × 2 6.35 × 2 6.35 × 2 6.35 × 3 6.35 × 3 6.35 × 4 6.35 × 4 6.35 × 5
Piping Gas mm 9.52 × 2 9.52 × 2 9.52 × 2 9.52 × 2 9.52 × 3 9.52 × 3 12.7×1+9.52×3 12.7×1+9.52×3 12.7×1+9.52×4
Total Piping Length (max) m 20 30 30 30 50 60 60 70 80
Each Indoor Unit Piping Length (max) m 15 20 20 20 25 25 25 25 25
3 3 3 3 3 3 3
Max. Height m 10 15(10)* 15(10)* 15(10)* 15(10)* 15(10)* 15(10) * 15(10) * 15(10)*3
Chargeless Length m 20 20 20 20 40 40 40 40 40
o
Guaranteed Operating Range Cooling C –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46
[Outdoor] Heating o
C –15 ~ +24 –15 ~ +24 –15 ~ +24 –20 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24

Type (Inverter Multi - Split Heat Pump) Up to 6 Indoor Units Up to 8 Indoor Units Type Branch Box
Indoor Unit Please refer to (*6) Model Name PAC-AK53BC*8 PAC-AK32BC
Outdoor Unit MXZ-6C122VA MXZ-8B140VA MXZ-8B140YA MXZ-8B160VA MXZ-8B160YA Connectable Number of Indoor Units Max. 5 Max. 3
Refrigerant R410A*1 Power Source Outdoor power supply
Power Source Outdoor power supply Supply Outdoor [V/Phase/Hz] VA:230 / Single / 50, YA:400 / Three / 50
Supply Outdoor (V/Phase/Hz) VA:230 / Single / 50, YA:400 / Three / 50 Total Input kW 0.003
Cooling Capacity Rated kW 12.2 14.0 14.0 15.5 15.5 Operating Current A 0.05
7
Min - Max kW 3.5 - 13.5 – – – – Drain Hose Size* mm O.D. 20 (VP - 16)
Input*7 Rated kW 4.05 3.86 3.86 4.71 4.71 Dimensions [HxWxD] mm 198 - 450 - 280
EER*6 3.01 3.52 3.52 3.21 3.21 Weight kg 9.3 8.1
EEL Rank B – – – – Piping Branch Liquid mm 6.35 × 5 6.35 × 3
Heating Capacity Rated kW 14.0 16.0 16.0 18.0 18.0 [diameter] [Indoor side] Gas mm 9.52 × 4,12.7 × 1 9.52 × 3
Min - Max kW 3.5 - 16.5 – – – – Main Liquid mm 9.52
Input*7 Rated kW 3.81 3.87 3.87 4.77 4.77 [Outdoor side] Gas mm 15.88
COP*6 3.67 3.91 3.91 3.61 3.61 Connection Method Flared
EEL Rank A – – – – Wiring to Indoor Unit 3-wire + Earth wire
Operating Current (max)*7 A 30.0 29.5 13.0 29.5 13.0 to Outdoor Unit 3-wire + Earth wire
Please refer to
Total Capacity of All Indoor Units (max) kW combination table 18.5 18.5 20.2 20.2
Outdoor Dimensions H×W×D mm 1070 -900 -320 (+67) 1350 - 950 - 330
Unit Weight kg 87 129 139 129 139
Air Volume Cooling m3/min 59.5 100.0 100.0 106.0 106.0
3
Heating m /min 69.9 100.0 100.0 106.0 106.0
Sound Level (SPL) Cooling dB(A) 55 50 - 47 50 - 47 51 - 48 51 - 48
Heating dB(A) 57 52 52 54 54
Sound Level (PWL) Cooling dB(A) 69 – – – –
Breaker Size A 32 40 25 40 25
Ext. Diameter Liquid mm 6.35 × 6 9.52 × 1 9.52 × 1 9.52 × 1 9.52 × 1
Piping Gas mm 12.7×1+9.52×5 15.88 × 1 15.88 × 1 15.88 × 1 15.88 × 1
Total Piping Length (max) m 80 115 115 115 115
Each Indoor Unit Piping Length (max) m 25 15 15 15 15
3 4 4 4
Max. Height m 15 (10)* 20 (30)* 20 (30)* 20 (30)* 20 (30)*4
Chargeless Length m 60 40 40 40 40
o
Guaranteed Operating Range Cooling C –10 ~ +46 –5 ~ +46 –5 ~ +46 –5 ~ +46 –5 ~ +46
[Outdoor] Heating o
C –15 ~ +24 –15 ~ +21 –15 ~ +21 –15 ~ +21 –15 ~ +21

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.
*4 If the outdoor unit is installed higher than the indoor unit, max. height is increased to 30m. *6 EER/COP, EEL rank, values and energy efficiency class are measured
*5 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured when connected to the indoor units listed below.
when connected to the indoor units listed below. MXZ-6C122VA MSZ-EF25VA × 6
MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VE MXZ-8B140VA MSZ-EF22VE × 8
MXZ-2D42VA MSZ-EF18VE + MSZ-EF25VE MXZ-8B140YA MSZ-EF22VE × 8
MXZ-2D53VA MSZ-EF18VE + MSZ-EF35VE MXZ-8B160VA MSZ-EF25VE × 8
MXZ-3D54VA2 MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE MXZ-8B160YA MSZ-EF25VE × 8
MXZ-3D68VA MSZ-EF18VE + MSZ-EF25VE + MSZ-EF25VE *7 Drain hose is to be locally purchased.
MXZ-4D72VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE *8 When using PAC-AK53BC and PAC-AK52YP-E, PLA-RP100BA and PEAD-RP100JA(L)Q can be connected
MXZ-4D83VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VE to MXZ-8B140V(Y)/160V(Y)A.
MXZ-5D102VA MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF22VE + MSZ-EF22VE

96

P093-98.indd 96 13.12.12 1:23:10 PM


Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit Inverter Models Heat pump type
5 5 5 5 5 5 5 5 6 6 6 6
MXZ- * MXZ- * MXZ- * MXZ- * MXZ- * MXZ- * MXZ- * MXZ- * MXZ- MXZ- * MXZ- * MXZ- * MXZ- *
Indoor Unit 2D33VA 2D42VA 2D53VA/H 3D54VA2 3D68VA 4D72VA 4D83VA 5D102VA 6C122VA 8B140VA 8B140YA 8B160VA 8B160YA

M series Wall- MSZ-FH25VE


Mounted
MSZ-FH35VE
MSZ-FH50VE
MSZ-SF15VA
MSZ-SF20VA
MSZ-SF25VE
MSZ-SF35VE
MSZ-SF42VE
MSZ-SF50VE
MSZ-GF60VE *3 *3 *3 *3 *3 *3 *3 *3 *3

MSZ-GF71VE *3 *3 *3 *3 *3 *3 *3

MSZ-EF18VE2W/B/S
MSZ-EF22VE2W/B/S
MSZ-EF25VE2W/B/S
MSZ-EF35VE2W/B/S
MSZ-EF42VE2W/B/S
MSZ-EF50VE2W/B/S
Floor- MFZ-KJ25VE *7
Standing
MFZ-KJ35VE *7
MFZ-KJ50VE
1-way MLZ-KA25VA
Cassette
MLZ-KA35VA
MLZ-KA50VA
S series 4-way SLZ-KA25VAQ2
Cassette
SLZ-KA25VAL2
SLZ-KA35VAQ
SLZ-KA35VAL
SLZ-KA50VAQ
SLZ-KA50VAL
Ceiling- SEZ-KD25VAQ *4
Concealed
SEZ-KD25VAL*4
SEZ-KD35VAQ
SEZ-KD35VAL
SEZ-KD50VAQ
SEZ-KD50VAL
SEZ-KD60VAQ
SEZ-KD60VAL
SEZ-KD71VAQ
SEZ-KD71VAL
P series 4-way PLA-RP35BA
Cassette
PLA-RP50BA
PLA-RP60BA
PLA-RP71BA
PLA-RP100BA
Ceiling- PCA-RP50KAQ
Suspended
PCA-RP60KAQ
PCA-RP71KAQ

Ceiling- PEAD-RP50JAQ *1 *1 *1 *1 *1 *1 *2 *2 *2 *2
Concealed
PEAD-RP50JALQ *1 *1 *1 *1 *1 *1 *2 *2 *2 *2

PEAD-RP60JAQ *1 *1 *1 *2 *2 *2 *2

PEAD-RP60JALQ *1 *1 *1 *2 *2 *2 *2

PEAD-RP71JAQ *1 *1 *1 *2 *2 *2 *2

PEAD-RP71JALQ *1 *1 *1 *2 *2 *2 *2

PEAD-RP100JAQ *2 *2 *2 *2

PEAD-RP100JALQ *2 *2 *2 *2

*1 Maximum total current of indoor units: 3A or less.


*2 Total indoor unit capacity should be 100% or less.
*3 The combination is still under evaluation.
*4 SEZ-KD25 cannot be connected with MXZ-2D/3D/4D/5D when total capacity of connected indoor units is equivalent to outdoor capacity (capacity ratio is 1).
*5 MXZ outdoor units are not designed to operate with a single indoor unit with one-to-one piping work. Please install at least two indoor units.
*6 Branch box PAC-AK53BC and PAC-AK32BC require connection of at least two indoor units connection.
*7 MFZ-KJ25/35VE “-E1” can not be connected with MXZ.

97

P093-98.indd 97 13.12.12 1:23:12 PM


Conditions for specifications

Temperature conditions are based on JIS B8616.

Indoor 27˚C DB, 19˚C WB


Cooling
Outdoor 35˚C DB, 24˚C WB

Indoor 20˚C DB
Heating
Outdoor 7˚C DB, 6˚C WB

Refrigerant piping length ; 5m


The figures for total input are based on the following voltages.

Series Indoor unit Outdoor unit


M Series
S Series
VE,VA,VHA,VKA:230V/Single phase/50Hz
P Series (except for PEA) -
YA,YHA,YKA:400V/Three phase/50Hz
MXZ Series
POWERFUL HEATING Series
PEA Series 400V/Three phase/50Hz 400V/Three phase/50Hz

Sound pressure level


• The sound pressure measurement is conducted in an anechoic chamber.
• The actual sound level depends on the distance from the unit and the acoustic environment.

How to read a model name

1) M & S Series
M M : M Series S : S Series
"S"= Wall-mounted , "F"= Compact floor-standing , "E"= Compact ceiling-concealed ,
S
"L"= 4- or 1-way cassette , "U"= Outdoor unit
Z "Z"= Inverter heat pump , "H"= Fixed-speed heat pump , "blank"= Cooling only

F Series
H Generation
25 Rated cooling capacity (kW base)
V 230V / Single phase / 50Hz
"A"= R410A with new A control , "B"= R410A with conventional control ,
E
"E"= R410A with new A control & ErP correspondance
"HZ"= Hyper Heating model , "H"= Anti-freeze heater equipped model ,
HZ
"S"= Silver indoor unit , "W"= White indoor unit , "B"= Black indoor unit

2) P Series
P P Series
"K"= Wall-mounted , "S"= Floor-standing , "L"= 4 -way cassette , "E"= Ceiling-concealed ,
U
"C"= Ceiling-suspended , "U"= Outdoor unit
H "H"= For heating and cooling , "blank"= Cooling only
Z "Z"= Inverter , "blank"= Fixed-speed

ZRP/RP/P "ZRP"/ "RP"= R410A & cleaning-free pipe reuse , "P"=R410A


SHW "SH"= Powerful heating ZUBADAN , "W"= can be used as air to water application
71 Rated cooling capacity (kW base)
V "V"= 230V / Single phase / 50Hz , "Y"= 400V / Three phase / 50Hz
H Generation
A "A"= A control

3) MXZ Series
M M Series
X Multi-system outdoor unit (heat pump)
Z Inverter heat pump

4 Maximum number of connectable indoor units


D Generation
72 Rated cooling capacity (kW base)
V "V"= 230V / Single phase / 50Hz , "Y"= 400V / Three phase / 50Hz
A "A"= R410A with new A control

98

P093-98.indd 98 13.12.12 1:23:12 PM


Major Optional Parts
Part Name Description Part Name Description

Deodourising Filter Quick-clean Kit


Captures small foul-smelling substances in Cleaning tool to remove dust on the filter, fan
the air. and heat exchanger. This tool can be easily
connected to a household vacuum cleaner for
quick, convenient cleaning of the units. Quick-clean kit

Deodourising filter

Anti-allergy Electric Enzyme Filter Drain Pump


This electrified filter catches dead mites and Pumps drain water to a point higher than that
their droppings, pollen and other allergens on where the unit is installed.
the filter filament, then decomposes them with
artificial enzymes.
Drain pump

Anti-allergy electric enzyme filter *for ceiling-suspended units

Air-cleaning Filter Decorative Cover Decorative cover


Removes fine dust particles from the air by To be attached to the upper section of ceiling-
means of static electricity. suspended models for professional kitchen
use. Helps prevent dust accumulation.
Decorative
cover
Indoor unit
Air-cleaning filter

Anti-allergen Enzyme Filter MA & Contact Terminal Interface MA & contact


Captures the bacteria, pollen and other aller- Interface for connecting with the PAR-31MAA terminal interface
gens in the air and neutralises them with the remote controller and PAC-YT52CRA, and to
enzyme in the filter. relay operation signals.

Anti-allergen enzyme filter


*for wall-mounted units

Catechin Air Filter System Control Interface System control


Contains catechin, which has antiviral and Interface to connect with M-NET controllers. interface
antibacterial characteristics.

Catechin air filter


*Example of installation in wall-mounted unit

Oil Mist Filter Element Filter frame


Wi-Fi Interface WiFi interface

Filter element (12 pieces) that blocks the oil Interface enabling users to control air condi-
mist for ceiling-suspended models used in tioners and check operating status via
professional kitchens. Filter element devices such as personal computers, tablets
and smartphones.
Oil mist filter Smartphone

High-efficiency Filter Element Plug


(for directing Connector Cable
airflow)
Element for high-efficiency filter. Removes Interface which inputs the incoming On/Off Switch
fine dust particles from the air. signals to the air conditioner and outputs
the On/Off signals from the air conditioner
High-efficiency
filter element
to the back-up heater.
Relay

*For 4-way cassette units

i-see Sensor Corner Panel i-see Sensor


corner panel
Power Supply Terminal Kit
Corner panel holding the i-see Sensor. Terminal bed to change the power supply
from outdoor power supply to separate indoor/
outdoor power supplies.

Shuttle Plate Wired Remote Controller


Plate for blocking an air outlet of the 4-way Advanced deluxe remote controller with full-
cassette indoor unit. dot liquid-crystal display and backlight.
Equipped with convenient functions like night-
Shuttle Plate
setback.

Multi-functional Casement Simple Wired Remote Controller


Casement for fresh-air intake and attaching Indoor unit body
Remote controller with liquid-crystal display,
the high-efficiency filter element (optional). and backlight function for operation in dark
Multi-functional
casement location.

Fresh-air Intake Duct Flange Remote Controller Terminal Block


Flange attachment for adding a duct to take in Kit for PKA
fresh air from outside. The terminal block is used as a relay to wire
an indoor unit and to two remote controllers or
to wire a remote controller and multiple indoor
units in order to perform group control.
*For 4-way cassette units

Space Panel Space Panel Wireless Remote Controller Signal


Decorative cover for the installation when the Sender
ceiling height is low. Handheld unit for sending operation signals to
Handheld unit
the indoor unit.

Panel

99

P099-118.indd 99 13.12.12 1:23:57 PM


Part Name Description Part Name Description

Wireless Remote Controller Signal Air Protection Guide


Receiver Protects the outdoor unit from the wind.
Receives operation signals from the wireless
remote controller handheld unit.
Signal receiver

Signal receiver
Wireless Remote Controller Kit Drain Socket
(Sender & Receiver) A set of caps to cover unnecessary holes at
Remote controller handheld unit (signal sender) the bottom of the outdoor unit, and a socket to
and receiver (signal receiver) for ceiling- Signal sender guide drain water to the local drain pipe. Cap

suspended units. Socket

Control Holder Centralised Drain Pan


Holder for storing the remote controller. Catches drain water generated by the outdoor Outdoor unit
Control holder
unit. Centralised drain pan

Base
(local construction)

Remote Sensor M-NET Converter


Sensor to detect the room temperature at Used to connect P Series A-control models to M-NET
Converter
remote positions. M-NET controllers.

Remote sensor

Remote On/Off Adapter Remote on/off adapter Control/Service Tool


Connector for receiving signals from the local Monitoring tool to display operation and self-
system to control the on/off function. diagnosis data.

Control/service tool

Remote Operation Adapter Remote operation adapter Step Interface Case interior
Adapter to display the operation status and Interface for adjusting the capacity of inverter-
control on/off function from a distance. equipped outdoor units. (For further details,
refer to pg. 130.) Installed in case

Connector Cable for Remote


Display Connector cable for remote display

Connector used to display the operation status


and control on/off function from a distance. Wi-Fi Interface ( )

21°C

Distribution Pipe Indoor unit


Indoor unit
Branch pipe for P Series simultaneous multi-
system use, or to connect two branch boxes MELCloud
for MXZ-8B140V(Y)A/160V(Y)A systems.
Outdoor unit
Distribution pipe

*P Series with 2 indoor units


MELCloud is a new Cloud based solution for
Joint Pipe controlling your Mitsubishi Electric Air Conditioning
Part for connecting refrigerant pipes of differ- Joint pipe Onsite pipe or Heating systems either locally or remotely by PC,
ent diametres. Indoor unit
Tablet or Smartphone via the Internet.
Outdoor unit
Insulator
Remote control
MELCloud allows you to take control of your Mitsubishi Electric systems
from anywhere in the world as long as you have internet access. So
Liquid Refrigerant Dryer forgetting to turn off your air conditioning or heating system when away on
Removes water and minute particles from holiday is no longer a problem.
refrigerant pipes.
Additional functions
MELCloud also provides some new functions, such as localised weather
information, frost protection, 7 day multi programmable timer and holiday
mode, with more features planned for the future.
Branch Box Outer Cover Complete view
User types
Casement for branch boxes.
MELCloud has been designed for wide range of users from single users
with single air conditioning or heating systems in a single building, up to
larger user who may have multiple properties and multiple systems that they
Branch box outer cover wish to monitor and control.
Whichever type of user you are, MELCloud can provide you with required
control and access you need for modern living.
Air Discharge Guide
✻Remote operation can be achieved as long as you have a connected system and you
Changes the direction of air being exhausted
have an internet connection at the location of your equipment.
from the outdoor unit.
✻Local operation is also possible if you close to where the system that you wish to
control is, but simply to not wish to use the local controller and have your PC, Tablet
or Smartphone to hand. Please note this is not direct connection via router, local
cotnrol still requires internet connection to work.

100

P099-118.indd 100 13.12.12 1:23:57 PM


Optional Parts List <Indoor>
Option Filter i-see
Multi- Fresh-air
Electrostatic Oil Mist Softdry Sensor Shutter Space Quick-
Anti-allergy Deodourising Catechin High-efficiency functional Intake Duct
Anti-allergy Filter Filter Box cloth Corner Plate Panel clean Kit
Enzyme Filter Filter Air filter Filter Element Casement Flange
Enzyme Filter Element Panel

MAC- MAC- MAC- MAC- MAC- MAC- MAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- MAC- PAC- PAC- PAC- PAC- PAC- PAC- MAC-
408 171 2310 2320 2330 3004 SG38 SH59 SH88 SH89 SH90 KE92 KE93 KE94 KE95 1001 SA1 SH51 SH53 SH65 SF28 SH48 093
Indoor Unit FT-E FT-E FT FT FT
3000FT-E
CF-E KF-E KF-E KF-E KF-E KF-E TB-E TB-E TB-E TB-E CL-E ME-E SP-E TM-E OF-E OF-E AS-E SS-E
Wall - MSZ-FH25VE
mounted MSZ-FH35VE
MSZ-FH50VE
MSZ-EF18VE2(W)(B)(S)
MSZ-EF22VE2(W)(B)(S)
MSZ-EF25VE2(W)(B)(S)
MSZ-EF35VE2(W)(B)(S)
MSZ-EF42VE2(W)(B)(S)
MSZ-EF50VE2(W)(B)(S)
MSZ-SF15VA
MSZ-SF20VA
M SERIES

MSZ-SF25VE
MSZ-SF35VE
MSZ-SF42VE
MSZ-SF50VE
MSZ-GF60VE
MSZ-GF71VE
MSZ-HJ25VA
MSZ-HJ35VA
MSZ-HJ50VA
Floor - MFZ-KJ25VE
standing MFZ-KJ35VE
MFZ-KJ50VE
1-way MLZ-KA25VA
cassette MLZ-KA35VA
MLZ-KA50VA
4-way SLZ-KA25VAQ2/VAL2
cassette SLZ-KA35VAQ/VAL
S SERIES

SLZ-KA50VAQ/VAL
Ceiling - SEZ-KD25VAQ/VAL
conceald SEZ-KD35VAQ/VAL
SEZ-KD50VAQ/VAL
SEZ-KD60VAQ/VAL
SEZ-KD71VAQ/VAL
4-way PLA-RP35BA
Cassette PLA-RP50BA
PLA-RP60BA
PLA-RP71BA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA2
PLA-ZRP35BA
PLA-ZRP50BA
PLA-ZRP60BA
PLA-ZRP71BA
PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA
Ceiling - PEAD-RP35JAQ
conceald PEAD-RP35JALQ
PEAD-RP50JAQ
PEAD-RP50JALQ
PEAD-RP60JAQ
PEAD-RP60JALQ
PEAD-RP71JAQ
PEAD-RP71JALQ
PEAD-RP100JAQ
P SERIES

PEAD-RP100JALQ
PEAD-RP125JAQ
PEAD-RP125JALQ
PEAD-RP140JAQ
PEAD-RP140JALQ
PEA-RP200GAQ
PEA-RP250GAQ
PEA-RP400GAQ
PEA-RP500GAQ
Wall - PKA-RP35HAL
mounted PKA-RP50HAL
PKA-RP60KAL
PKA-RP71KAL
PKA-RP100KAL
Ceiling - PCA-RP35KAQ
suspended PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
PCA-RP71HAQ
Floor - PSA-RP71KA
standing PSA-RP100KA
PSA-RP125KA
PSA-RP140KA

*1 P Series indoor units can be used in combination with SUZ or MXZ outdoor units. *2 P Series indoor units can be used in combination with SUZ or MXZ outdoor units (MAC-333IF-E or MAC-397IF-E required).

101

P099-118.indd 101 13.12.12 1:23:57 PM


MA & Wired Remote Controller Wireless Remote Controller Connector
System Controller Remote Remote
Decorative Control Contact Wi-Fi Connector Power Supply Terminal Remote Cable
Drain Pump
Cover Interface Terminal Interface Cable Terminal Kit Controller Signal Signal Kit Controller Sensor On/ Off Operation for Remote
Block kit Sender Receiver (Sender & Holder Adapter Adapter
Interface for PKA Receiver) Display

PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAR- MAC- PAC- PAC- PAC- PAC-
MAC- MAC- MAC- MAC- MAC- PAC- PAC- PAC- PAC- PAR- PAC- PAC- PAR- PAR- PAR-
SH94 SH75 SH83 SH84 SH85 KE07 SF81 SF82 SL94 1200 SE41 SE55 SF40 SA88
333IF 397IF-E 557IF-E 1702RA-E 1710RA-E SG94 SG96 SG97 SH52 31MAA YT52CRA SH29TC-E SL97A-E SA9C SA9F
DM-E DM-E DM-E DM-E DM-E DM-E KC-E KC-E HR-E HR-E HR-E HR-E A-E A-E B-E RC TS-E RA-E RM-E HA-E
*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

*3 *3

VAQ VAQ *4

VAQ VAQ *4

VAQ VAQ *4

VAQ VAQ *4

VAQ VAQ *4

VAQ VAQ *4

VAQ VAQ *4

VAQ VAQ *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*4

*4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*5

*5

*1 *1

*1 *1

*1 *1

*1 *1

*1 *1

*1 *1 *4

*1 *1 *4

*1 *1 *4

*1 *1 *4

*4

*4

*4

*4

*4

*4

*4

*4

*3 MAC-397IF-E is required. *4 Unable to use with wireless remote controller. *5 Two interface components required for each indoor unit.

102

P099-118.indd 102 13.12.12 1:23:57 PM


Optional Parts List <Outdoor>
Distribution Pipe Joint Pipe Liquid Refrigerant Dryer
Option
Unit Unit Unit Unit Unit Unit Unit Unit Unit
For For For ø6.35 ø9.52 ø12.7 ø15.88 ø9.52 ø6.35 ø9.52 ø12.7 ø12.7
Flare Y-shaped For For For
Twin Triple Quadruple Brazed --> --> --> --> --> --> --> --> --> pipe pipe pipe
Connection pipe
(50:50) (33:33:33) (25:25:25:25) Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe ø6.35 ø9.52 ø12.7
ø9.52 ø12.7 ø15.88 ø19.05 ø15.88 ø9.52 ø12.7 ø9.52 ø15.88
PAC- PAC- PAC- PAC- PAC- PAC- MAC- MAC- MAC- PAC- PAC- PAC- PAC-
MSDD- MSDD- MSDT- MSDF- MSDD- MSDD-
SG72 SG73 SG74 SG75 SG76 493 A454 A455 A456 AK52 SG81 SG82 SG85
Outdoor Unit 50TR-E 50WR-E 111R-E 1111R-E 50AR-E 50BR-E
RJ-E RJ-E RJ-E RJ-E RJ-E PI JP-E JP-E JP-E YP-E DR-E DR-E DR-E
F Series MUZ-FH25VE
MUZ-FH25VEHZ
MUZ-FH35VE
MUZ-FH35VEHZ
MUZ-FH50VE
MUZ-FH50VEHZ
E Series MUZ-EF25VE
MUZ-EF25VEH
MUZ-EF35VE
MUZ-EF35VEH
MUZ-EF42VE
MUZ-EF50VE
S Series MUZ-SF25VE
MUZ-SF25VEH
M SERIES

MUZ-SF35VE
MUZ-SF35VEH
MUZ-SF42VE
MUZ-SF42VEH
MUZ-SF50VE
MUZ-SF50VEH
G Series MUZ-GF60VE
MUZ-GF71VE
H Series MUZ-HJ25VA
MUZ-HJ35VA
MUZ-HJ50VA
Compact MUFZ-KJ25VE
floor MUFZ-KJ25VEHZ
MUFZ-KJ35VE
MUFZ-KJ35VEHZ
MUFZ-KJ50VE
MUFZ-KJ50VEHZ
S SERIES SUZ-KA25VA4
SUZ-KA35VA4
SUZ-KA50VA4
SUZ-KA60VA4
SUZ-KA71VA4
POWERFUL PUHZ-SHW80VHA
HEATING PUHZ-SHW112VHA
PUHZ-SHW112YHA
PUHZ-SHW140YHA
Power PUHZ-ZRP35VKA
Inverter PUHZ-ZRP50VKA
PUHZ-ZRP60VHA
PUHZ-ZRP71VHA
PUHZ-ZRP100VKA
PUHZ-ZRP100YKA
PUHZ-ZRP125VKA
PUHZ-ZRP125YKA
P SERIES

PUHZ-ZRP140VKA
PUHZ-ZRP140YKA
PUHZ-RP200YKA
PUHZ-RP250YKA
Standard PUHZ-P100VHA4
Inverter PUHZ-P125VHA3
PUHZ-P140VHA3
PUHZ-P200YHA3
PUHZ-P250YHA3
PUHZ-P100YHA2
PUHZ-P125YHA
PUHZ-P140YHA
MXZ SERIES MXZ-2D33VA
MXZ-2D42VA
MXZ-2D53VA(H)
MXZ-3D54VA2
MXZ-3D68VA
MXZ-4D72VA
MXZ-4D83VA
MXZ-5D102VA
MXZ-6C122VA
MXZ-8B140VA
MXZ-8B140YA
MXZ-8B160VA
MXZ-8B160YA

*1 Operation in “AUTO” step mode only: make sure to turn OFF “SW2-6” and put “TH5” (2 phose pipe thermistor) at the appropriate position.

103

P099-118.indd 103 13.12.12 1:23:57 PM


Step Interface
Branch Freeze-
Control/
Box prevention M-NET 1 PC board
Air Discharge Guide Air Protection Guide Drain Socket Centralized Drain Pan Service
Outer Heater Converter Tool wattachment
/ attachment kit
kit
Cover (for Drain Pan)

PAC- MAC- MAC- MAC- MAC- MAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- MAC- MAC- PAC- PAC- PAC- PAC- PAC-
PAC- PAC-
AK350 889 856 886 883 857 SJ07 SG59 SH96 SJ06 SH63 SH95 SF37 SJ08 SG61 643 644 SG63 SG64 SH97 SJ19 SF83
SK52ST IF012B-E
CVR-E SG SG SG-E SG SG SG-E SG-E SG-E AG-E AG-E AG-E DS-E DS-E DS-E BH-E BH-E DP-E DP-E DP-E MA-E MA-E

*1
*1
*1
*1
*1

*1
*1
*1
*1
*1
*1
*1
*1

104

P099-118.indd 104 13.12.12 1:23:57 PM


External Dimensions
Unit : mm
MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-EF18VE2(W)(B)(S) MSZ-EF22VE2(W)(B)(S)
MSZ-EF25VE2(W)(B)(S) MSZ-EF35VE2(W)(B)(S)
INDOOR UNIT
MSZ-EF42VE2(W)(B)(S) MSZ-EF50VE2(W)(B)(S)
INDOOR UNIT

925 885
875 5
905 10

left under piping


(using spacer),
In case of left,
Air in

111 or more.
57 or more

left back,or
Installation plate Air in Installation
plate
Piping
35 or more 35 or more
Piping

299
17

7
100

56

25 39 51 Drain hose
47

100

58
7 or more
61 704 160 101
(80°) 94 Drain hose
117
Air out 110
132 59 678 158
Air out

60 18
60 18
193

193

MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE MSZ-GF60VE MSZ-GF71VE


INDOOR UNIT INDOOR UNIT

798
1100
778 10
1090 5

Air in
Installation plate 238
Air in
Piping Installation plate
5
299

325

Piping
7

67
100

12
58

61 577 160 47 Drain hose


100

( 80 ) 92 76 843 181 65
3

( 70∞) 125 Drain hose


108.5 160
Air out 184
Air out
60 18
60 18
193

193

105

P099-118.indd 105 13.12.12 1:23:57 PM


Unit : mm
MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA MSZ-SF15VA MSZ-SF20VA
INDOOR UNIT INDOOR UNIT

799
785 7 760
740 10
46

Air in
Installation plate 168 5
Installation plate
Piping
Piping
290

250
57
100
14
7

56
42 56 505 179 41 Drain hose
Drain hose
103 110
Air out
(5

49 630 120

130
)

Air out 172

57 18 60 18
140

193

MFZ-KJ25VE MFZ-KJ35VE MFZ-KJ50VE


INDOOR UNIT

730

Remote controller
60 19
193

750
47 656 47
No obstruction

28 215
70
26

Air out
Gas pipe
25/35: ø9.52 (flared) 3/8
More than More than 50: ø12.7 (flared) 1/2
100mm 100mm 148 Liquid pipe
15 ø6.35 (flared) 1/4
15
600

Sensor hole
303

Air in
205
165
125
60

12
30
127
Less than
150mm

60
Drain
104
47 656 47 131
153

106

P099-118.indd 106 13.12.12 1:23:58 PM


Unit : mm
MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA
INDOOR UNIT
(Top) (Top)
Center of ceiling opening,
49.7 13.5 Center of ceiling opening, suspension bolt pitch suspension bolt pitch and grille
and grille are located in one position. Wireless are located in one position.

38
15
remote controller

26
58

414 Outer side of grille


384 Ceiling opening
2

308 Suspension bolt pitch


58 18

Suspension bolt pitch


Pipe
2 cover

230

308
158
180

Electrical box

Drain hose 15
(51.6)

38
15
Air outlet connecting part 26 Air outlet
16 16 Outlet
1051 Suspension bolt pitch 54.5 1051 Suspension bolt pitch 54.5
20 1160 Ceiling opening 20
1200 Outer side of grille
(Right side)
360
(Front) Drain hose 244
1102 Drain hose
170
960 78 Gas pipe
(Front)
110 Suspension bolt M10
Liquid pipe
Drain pipe

180 or more

175
175
116
110

112

Pipe cover
60
25

31

Electrical box Drain pan Ceiling Ceiling surface Grille Ceiling surface
Outlet opening area 48
Display and surface
0.04m2 58 No gaps between receiving section
the ceiling surface and grille

Grille (MLP-440W)
34
1200
Receiving section
CL
R6
172.4
166.5
81.8
414

0 CL

166.5
173 6
R6
Hole position for the
installation of grille
0
10
466.5

466.5

107

P099-118.indd 107 13.12.12 1:23:58 PM


Unit : mm
MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE MUZ-FH50VEHZ
MUZ-FH25VEHZ MUZ-FH35VEHZ MUZ-EF50VE
MUZ-EF25VE MUZ-EF25VEH MUZ-SF50VE MUZ-SF50VEH
MUZ-EF35VE MUZ-EF35VEH MUZ-GF60VE MUZ-GF71VE
MUZ-EF42VE MUFZ-KJ50VE MUFZ-KJ50VEHZ
MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE
OUTDOOR UNIT
MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH
MUZ-HJ50VA 417.5
MUFZ-KJ25VE MUFZ-KJ35VE Drain hole 42
Air in
MUFZ-KJ25VEHZ MUFZ-KJ35VEHZ 40

OUTDOOR UNIT

50
330

360
400 Drain hole ø42
Air in

Air out
Bolt pitch for
installation

2-holes 10 21
304-325
44
344.5

175 500
285

Air in

840 81
109 Service panel
40
17.5

2 holes 10 21
Air out
Service panel
22.3 23
Liquid refrigerant Liquid refrigerant
pipe joint pipe joint
Handle Refrigerant pipe Refrigerant pipe
(flared) ø6.35 880 (flared) ø6.35

35
452
550

35

43

44
280

164.5
164.5

99.5
Gas refrigerant Gas refrigerant
10

pipe joint pipe joint


195 Refrigerant pipe
150 69 Refrigerant pipe
99.5

170.5 (flared) ø9.52 (flared) ø12.7

302.5 Service port

500 Bolt pitch for installation

800

MUZ-HJ25VA MUZ-HJ35VA
OUTDOOR UNIT

Air in
Drain hole ø33
41.5

Bolt pitch for


installation
294~267

Air in
285
19.6

Air out
2-10.3×19.3 Oval hole
349.5

249
17.9

Liquid refrigerant pipe joint


Refrigerant pipe (flared) ø6.35
Gas refrigerant pipe joint
538

Refrigerant pipe (flared) ø9.52


270.3

43°
40
157.7

°
13.5

102.7

259 121.4
121 500
699 55.7

108

P099-118.indd 108 13.12.12 1:23:58 PM


Unit : mm
SLZ-KA25VAQ2 SLZ-KA35VAQ SLZ-KA50VAQ
SLZ-KA25VAL2 SLZ-KA35VAL SLZ-KA50VAL
INDOOR UNIT
650
15~37

Fresh-air
intake
576~620 Ceiling hole

530
Suspension bolt
Suspension bolt pitch

pitch
420

335

570
650

570

31

87
15~37

57
56

199
352
335
15~37 576~620 Ceiling hole 15~37
Drain pipe Wiring entry
Refrigerent pipe (gas) 17 202 230

Refrigerent pipe (liquid)


66

182
193
208
235
121
93

Suspension bolt
48

M10 or 3/8
(purchace locally)
Suspension bolt

20
+5

Grille
27 0

Terminal block Ceiling surface


Terminal block
lower edge

(Wired remote controller)


38~58

SEZ-KD25VAQ SEZ-KD35VAQ SEZ-KD50VAQ SEZ-KD60VAQ SEZ-KD71VAQ


SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
INDOOR UNIT 20 157.5
15 12 37 100 37
88
B (Suspension bolt pitch)
100X(E-1)=F

100XJ=K
D (Duct)

H
C
A

Air Air
outlet inlet
100
100

88
30
57

20
20

12
25

10
23

L- 2.9
2XE- 2.9
90

49 625 (Suspension bolt pitch) Air filter


Knockout hole 27
Suspension bolt hole
(Remote controller transmission line)

Refrigerant piping 700 4-14X30 Slot Knockout hole 27


23 677 (Indoor/outdoor connecting line)
flare connection (liquid) Control box
10
23
25

102
150 (Duct)

170
100

200

2X2- 2.9 116 70 Terminal block

Refrigerant piping 270 Terminal block (Indoor/outdoor connecting line)


(Remote controller transmission line)
flare connection (gas) Notes:
Drain pipe(Spontaneous draining)
1. Use M10 bolts for suspension (purchase locally).
Model A B C D E F G H J K L 2. Keep service space for maintenance at the bottom.
SEZ-KD25VAL/VAQ 700 752 798 660 7 600 800 660 5 500 16 3. This chart is based on the SEZ-KD50VAL/VAQ, which has three fans.
SEZ-KD35VAL/VAQ SEZ-KD25, 35VAL/VAQ has two fans, and SEZ-KD60, 71VAL/VAQ has four fans.
900 952 998 860 9 800 1000 860 7 700 20
SEZ-KD50VAL/VAQ 4. If an inlet duct is used, remove the air filter supplied with the unit,
SEZ-KD60VAL/VAQ and install a locally purchased filter on the suction side.
1100 1152 1198 1060 11 1000 1200 1060 9 900 24
SEZ-KD71VAL/VAQ

109

P099-118.indd 109 13.12.12 1:23:59 PM


Unit : mm
SUZ-KA25VA4 SUZ-KA35VA4 SUZ-KA50VA4 SUZ-KA60VA4 SUZ-KA71VA4
OUTDOOR UNIT OUTDOOR UNIT

417.5
Drain hole 42
Air in 40

400 Drain hole


Air in

50
330

360
Bolt pitch for
installation
304~325
44
344.5

285

Air in

Air out
2-holes 10 21
175 500
40
17.5

2 holes 10X21
Air out Service panel 840 81
22.3 23
109 Service panel

Handle Liquid refrigerant pipe joint


Refrigerant pipe (flared)

Liquid refrigerant
550

pipe joint
35

43

Refrigerant pipe

880
280

(flared)
164.5

Gas refrigerant pipe joint


10

Refrigerant pipe (flared)


150

35
69

452
99.5

170.5

44
302.5 Service port

164.5
99.5
500 Bolt pitch for installation Gas refrigerant
pipe joint
800 195 Refrigerant pipe
(flared)

110

P099-118.indd 110 13.12.12 1:23:59 PM


Unit : mm
PLA-RP35BA PLA-RP50BA PLA-RP60BA PLA-RP71BA PKA-RP35HAL PKA-RP50HAL
PLA-RP100BA PLA-RP125BA PLA-RP140BA2 INDOOR UNIT
PLA-ZRP35BA PLA-ZRP50BA PLA-ZRP60BA PLA-ZRP71BA
PLA-ZRP100BA PLA-ZRP125BA PLA-ZRP140BA
INDOOR UNIT
387 192
950 Top side
Ceiling hole
20~45 860~910 20~45
810
Fresh air Suspension bolt pitch
20~45
intake hole 160

197
(7.5)
160

Remote controller
terminal block
Indoor unit/Outdoor
Suspension bolt pitch

unit connecting
599
Ceiling hole

Branch duct hole


terminal block
860~910

Branch duct hole


605
840

620
950

Indoor power supply


terminal block(optional part)
Mounting board

Front side Right side


150

160
24
D
90
C

(7.5)

20~45

187.5 160
840
Suspension bolt

295
M10 or W3/8
Detail connecting of branch duct
Refrigerant pipe Drain pipe 90 100 100 90
60 284 377 Cut out hole
(liquid)
100
130

Refrigerant pipe
(gas)
70

5
A

249
B

55 688 155
190

155
167
156
170

105
140

898
Suspension bolt
50~70

lower edge Power supply wire,


17 +50
35

Ceiling 350
Control wire entry
Indoor unit/Outdoor unit 175 14- 2.8
connecting wire entry Grille
Keep approximately Burring hole pitch 150 Burring hole
10 to 15mm space Cut out hole
between unit ceiling
and ceiling slab.

Models A B C D E Models A B C D E
PLA-RP35/50BA PLA-ZRP35BA
80
PLA-ZRP50BA 241 258 74 400
80
PLA-ZRP60BA 87
74 PLA-ZRP71BA
PLA-RP60BA 241 258 400 PLA-ZRP100BA
281 298 85 77 440
87 PLA-ZRP125BA
PLA-ZRP140BA
PLA-RP71BA
PLA-RP100,125BA 85 77
PLA-RP140BA2 281 298 440

PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL PCA-RP35KAQ PCA-RP50KAQ


INDOOR UNIT INDOOR UNIT

51
2 960 2 10
423.7 431.7 Top side
853 5
65.2

84 88

230
195
140.3

Air outlet
11

184 (liquid (
203 (gas (
233 ( When drain socket (
is installed
Mounting board 246 (Drainage)
57

Front side Right side


680
476
365

254

295 5 182 85
74 (855) 241
878
1170

Air intake

111

P099-118.indd 111 13.12.12 1:23:59 PM


Unit : mm
PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ
INDOOR UNIT INDOOR UNIT

51
2 1280 2 10 51
2 1600 2 10
1173 5
1493 5

236
84 88

230

84 88

230
195

236
195
Air outlet A
(liquid)
Air outlet 180
200
(liquid)
B (gas)
(gas)
233
(When drain socket
(
233 (When drain socket
is installed (
is installed 246
246 (Drainage)
(Drainage)

57
57

680
680

476
476

254
60 71
A 179 180
254

B 203 200 182 85


1518
182 85
Air intake
1198

Air intake

PCA-RP71HAQ PSA-RP71KA PSA-RP100KA PSA-RP125KA PSA-RP140KA


INDOOR UNIT INDOOR UNIT
Rear side Knockout hole
for branch duct
240 10
<liquid>

10
38

Terminal block box 130 15


<gas>

Electrical box 2
111

132
38 15
21
110
175
197

100
130

Front side
1 125
340
370 Metal fixture
against overturning
520 360
260
240
40
20

40
10

1224 75 495
Suspension bolt
<Suspension bolt pitch>
260

1180 320 80
<Suspension bolt pitch>
43
70~90
75
102

<Air outlet>

140
243

254
280

295
110

Controller
130
13

70 129 71
986 <Air outlet>
820

75 289
1136 650 3
Inspection port
(pipe sensor)
1900

<Flexible hose(accessory)>

Refrigerant pipe connection(gas pipe side/flared connection)


Refrigerant pipe connection(liquid pipe side/flared connection)
Flexible hose(accessory) Drainage pipe connection
599
834

50
181

115

70
30

524 260
600 310 Knockout hole for wiring 27
Knockout hole for refrigerant and drainage (Provided on both sides)
90×60 oval (Provided on both sides)

112

P099-118.indd 112 13.12.12 1:23:59 PM


Unit : mm
PEAD-RP35JAQ PEAD-RP50JAQ PEAD-RP60JAQ PEAD-RP71JAQ PEAD-RP35JALQ PEAD-RP50JALQ PEAD-RP60JALQ
PEAD-RP100JAQ PEAD-RP125JAQ PEAD-RP140JAQ PEAD-RP71JALQ PEAD-RP100JALQ PEAD-RP125JALQ
INDOOR UNIT PEAD-RP140JALQ
2xE- 2.9 Suspension bolt hole INDOOR UNIT
15 4-14x30 Slot
2xE- 2.9 Suspension bolt hole
15 4-14x30 Slot

B(Suspension bolt pitch)


100x(E-1)=F

B(Suspension bolt pitch)


D (Duct)

C
A
Air

100x(E-1)=F
Air
outlet inlet

D (Duct)

C
A
Air Air
outlet inlet
100

100
30
57 20

30
57 20
40

10
23
58

24
57 643(Suspension bolt pitch) 10

23
Terminal block 57 643(Suspension bolt pitch)
Refrigerant piping (Remote controller
732
transmission line) Refrigerant piping 732
Flare connection (liquid) 32 700 Flare connection (liquid) 32 700 Terminal block
238 Drain pipe Drain pump (Remote controller
122
23

10 10
(O.D. 32)

122
41
40

23
transmission line)

40
178(Duct)

178(Duct)
217
100

217
250

100

250
33

33

Control box
2 2- 2.9 Control box
2 2- 2.9
136 67 136 67
Refrigerant piping Drain pipe Terminal block Refrigerant piping Terminal block
356 356
Flare connection (gas) (Spontaneous draining) (Indoor/Outdoor Drain pipe (Indoor/Outdoor
Flare connection (gas)
connecting line) connecting line)
Model A B C D E F Model A B C D E F
PEAD-RP35,50JAQ 900 954 1000 860 9 800 PEAD-RP35,50JALQ 900 954 1000 860 9 800
PEAD-RP60,71JAQ 1100 1154 1200 1060 11 1000 PEAD-RP60,71JALQ 1100 1154 1200 1060 11 1000
PEAD-RP100,125JAQ 1400 1454 1500 1360 14 1300 PEAD-RP100,125JALQ 1400 1454 1500 1360 14 1300
PEAD-RP140JAQ 1600 1654 1700 1560 16 1500 PEAD-RP140JALQ 1600 1654 1700 1560 16 1500

113

P099-118.indd 113 13.12.12 1:23:59 PM


Unit : mm
PEA-RP200GAQ PEA-RP250GAQ
INDOOR UNIT INDOOR UNIT

<Accessory> 124 1302 34


Pipe cover....................2pcs. 66 9X130(=1170) 66
<Accessory> (For dew condensation prevention of local piping and unit connection) 42
130
Pipe cover....................2pcs. Remote controller.........1pc.
(For dew condensation prevention of local piping and unit connection) 124 1102 34 Return air
Remote controller........1pc. duct flange

10
31 8x130(=1040) 31

100
42 130
Rubber bushing <Remote Return-air 26- 3 Holes

199
duct flange Control box

10
controller wiring>
70 75 129

100

Rubber bushing
<Remote

462
Rubber bushing

70 75 129
24- 3 Holes 20 1500 20

200
199
<Outdoor unit Control box controller wiring>
connection wiring> Rubber bushing
<Outdoor unit 22- 3.1
462

131
Rubber bushing 20 1300 20

200
55 connection wiring>
<Power supply wiring>

40
22- 3.1 Rubber bushing

10
55 Fresh-air 130

131
<Power supply 4- 12
intake duct 45
A wiring>
flange
7x130(=910) 45 <For hanging bolt M10>
40

[Field supply]

10
Fresh-air 130
intake duct 45
flange
7x130(=910)
4- 12
45 <For hanging bolt M10> A Top view
[pwehase locally]
Top view 634
1600
1540
Refrigerant pipe 40 1460 40
(gas) 50 530 54
1400 10 10 255 1000 205
Return air
1340

22
sensor

130 130 35
Return air 634
sensor 40 1260 40

73
50 530 54

100 100 25

95
145 144
Refrigerant pipe 10 10 155 1000 105
(gas)
22

330

376

400
262
130 130 35

250
A
73

95
100 100 25

Return air Supply air


145 144
330

376

400
262

11
25
35
250

89
A 39 565 1484
Return air Supply air
Refrigerant pipe Drain
11
89
35

25

(Liquid)
39 565 1284

Refrigerant pipe
(liquid)
Drain Left view Front view
Left view Front view

PEA-RP400GAQ PEA-RP500GAQ
INDOOR UNIT

<Accessory> 149 1618 33


Pipe cover...................4pcs. 29 12X130(=1560) 29
(For dew condensation prevention of local piping and unit connection) 45 130
Remote controller.......1pc.
Return-air
10
100

duct flange
60 60 60 40
36- 3 HOLES
203
61

Control box
Rubber bushing Rubber bushing
320

20 1840 20
425

<Power supply wiring> <Remote controller wiring>

Rubber bushing 24- 3.1


141

<Outdoor unit connection wiring>


59

A
10

130 4- 15
Fresh-air intake 42.5 8X130(=1040) 42.5 <For hanging bolt M12>
duct flange
[Field supply]

Top view
Refrigerant pipe (gas)

764 1947
1880
50 664 50 40 1800 40
10 10 395 1125 280
Return air sensor
22.5
81

(2 places)
22

188
4X120(=480)
117 156 117
120

40
525

595
570
130 130

340

Return air Supply air


22.5

22
102

40

A 1824
39 700

Drain Front view


Refrigerant pipe
(liquid)
Left view

114

P099-118.indd 114 13.12.12 1:24:00 PM


Unit : mm
PUHZ-SHW80VHA PUHZ-SHW112VHA PUHZ-ZRP35VKA PUHZ-ZRP50VKA
PUHZ-SHW112YHA PUHZ-SHW140YHA
OUTDOOR UNIT
OUTDOOR UNIT
Rear Air Intake
2-U Shaped notched holes
(Foundation Bolt M10) A
175 600 175 404.5
SHW·VHA 1079
Installation Feet

(19)
SHW·YHA 930 Air intake 42 drain hole
Side Air Intake

48
330

417
370
56
45

300
330
360
66 42 Air intake
30

28
53

Air Discharge 2-12 x 36 Oval holes


(Foundation Bolt M10)
Air discharge

32.5
Handle for moving 40
950
322 Earth terminal
Terminal connection 4-10×21 oval hole
Left ····Power supply wiring
Right··· Indoor/Outdoor wiring

( )
Terminal connection
Handle for moving Left Power supply wiring
Right Indoor/Outdoor wiring
22.3
Handle Service panel
for Service panel for charge plug
moving

Handle for moving Earth terminal


1350
635

Service panel
630

2
Connection for
A

liquid pipe
320

FLARE 6.35 (1/4F)


8.5

Connection for
1 447
1 443

gas pipe
371

154.5
FLARE 12.7 (1/2F)
310 Service port
Installation bolt pitch
500
23

Front piping cover

Rear piping cover 809 62


...Refrigerant gas pipe connection (flare)
...Refrigerant liquid pipe connection (flare)
...Indicates stop valve connection location.

PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA PUHZ-ZRP125VKA PUHZ-ZRP140VKA


OUTDOOR UNIT PUHZ-ZRP100YKA PUHZ-ZRP125YKA PUHZ-ZRP140YKA
OUTDOOR UNIT
Rear air intake
Rear air intake 2 U-shaped notched holes
2 U-shaped notched holes (Foundation Bolt M10)
(Foundation Bolt M10) 225 600 225
Installation Feet
19

175 600 175


19

Installation Feet
Side air intake Side air intake
370
417
330

56
330

417
370

40
0
40
54

53
30

70 60 42
28

Air discharge 2-12 36 Oval holes


30

57 41
28
53

(foundation bolt M10)


2-12 36 oval holes 1050
(foundation bolt M10) 362
Handle for moving Earth terminal Terminal connection
Left...Power supply wiring
Air discharge Right..Indoor/Outdoor wiring

950
Terminal connections
322 Earth terminal Left:Power supply wiring
Handle for moving
Right : Indoor / Outdoor wiring Service panel
Service panel

Handle for moving


632
1338

Handle for moving


A

Air intake
943

2 1
1
673

450
442
369

2
447
473

431

26

Front piping cover


1 ...Refrigerant gas pipe connection (flare) Rear piping cover
2 ...Refrigerant liquid pipe connection (flare)
23

Front piping cover


...Indicates stop valve connection location.
Rear piping cover
...Refrigerant gas pipe connection (flare) Model A
...Refrigerant liquid pipe connection (flare) PUHZ-ZRP100~140VKA 1067
...Indicates stop valve connection location. PUHZ-ZRP100~140YKA 919

115

P099-118.indd 115 13.12.12 1:24:00 PM


Unit : mm
PUHZ-RP200YKA PUHZ-RP250YKA PUHZ-P100VHA4 PUHZ-P100YHA2
OUTDOOR UNIT OUTDOOR UNIT

Rear air intake


2 U-shaped notched holes
(foundation bolt M10) Rear Air Intake 2-U Shaped notched holes
(Foundfation Bolt M10)
225 600 225
Installation Feet

19
175 600 175

(19)
Installation Feet
Side air intake

370
417
330

Side Air Intake


56

330

417
370
40
0

E
F
53
70 60 42
30

28

2-12 36 oval holes


(foundation bolt M10) C D

53
28
Air discharge

30
Air Discharge 2-12 x 36 oval holes
(Foundation Bolt M10)
Handle for moving 1050 Terminal connections
362 Earth terminal Left...Power supply wiring
Right...Indoor/Outdoor wiring 950
Terminal Connections
322 Earth terminal Left···Power supply wiring
Handle for moving
Right···Indoor/Outdoor wiring

Service panel

Handle for moving


Service panel
1338

Handle for moving


632

943

B
1
982
986

Air intake
473

1 447
1 A
2
Brazing
*1 A
*1 B
369

342

23

Front piping cover

Rear piping cover


26

Front piping cover


1 ...Refrigerant gas pipe connection (attached joint) Rear piping cover
2 ...Refrigerant liquid pipe connection (flare)
···Refrigerant GAS pipe connection (FLARE) A B C D E F
···Refrigerant LIQUID pipe connection (FLARE) PUHZ-P100VHA4 443 670 66 42 45 56
*1...Indicates of stop valve connection location. 1 ···Indication of STOP VALVE connection location. PUHZ-P100YHA2 431 589 56 41 41 54

Model A B
PUHZ-RP200YKA 450 -
PUHZ-RP250YKA 424 442

PUHZ-P125VHA3 PUHZ-P140VHA3 PUHZ-P200YHA3 PUHZ-P250YHA3


PUHZ-P125YHA PUHZ-P140YHA OUTDOOR UNIT
OUTDOOR UNIT Rear Air Intake
2-U Shaped notched holes
Rear Air Intake
2-U Shaped notched holes
(Foundation Bolt M10) (Foundation Bolt M10)
175 600 175 175 600 175
Installation Feet Installation Feet
(19)

(19)

Side Air Intake Side Air Intake


330

330
417

417
370

370
54

56
41

40

56 41
30

30

61 37
28

28
53

53

Air Discharge 2-12 x 36 Oval holes Air Discharge 2-12 x 36 Oval holes
(Foundation Bolt M10) (Foundation Bolt M10)

950 950

Handle for moving 322 Handle for moving 322


Earth terminal Earth terminal
Terminal connection Terminal connection
Left···Power supply wiring Left···Power supply wiring
Right···Indoor/Outdoor wiring Right···Indoor/Outdoor wiring

Service panel Service panel

Handle for moving Handle for moving


1350

1350
635

635

2
995
999
A

1
Brazing

2
1 447

1 439
1 431

2 339
371

371

1A
23

23

Front piping cover Front piping cover

Rear piping cover Rear piping cover

···Refrigerant GAS pipe connection (FLARE) A ···Refrigerant GAS pipe connection (FLARE) A
···Refrigerant LIQUID pipe connection (FLARE) PUHZ-P125/140VHA3 1076 ···Refrigerant LIQUID pipe connection (FLARE) PUHZ-P200YHA3 447
1 ···Indication of STOP VALVE connection location. PUHZ-P125/140YHA 994 1 ···Indication of STOP VALVE connection location. PUHZ-P250YHA3 421
2 ···Refrigerant GAS pipe connention(brazed)

116

P099-118.indd 116 13.12.12 1:24:00 PM


Unit : mm
MXZ-2D33VA MXZ-2D42VA MXZ-2D53VA MXZ-2D53VAH MXZ-3D54VA2 MXZ-3D68VA
OUTDOOR UNIT OUTDOOR UNIT

169 500 171


400 Drain hole ø42 (In case of Base heater models ø33) 65.4 207.5 314

17.7
Air in

34
Air in

16.6

18.3

(Bolt Pitch)
304~325

360.6
344.5

396
Air in
Air in
17.5

12.3
17.7
40 Air out
Air out Drain hole 3-ø33
4-10×21 Oval hole
(Foundation bolt M8)
2-10×21 Oval hole
22.3 18 285 13 840 30
Handle 200 25.8 330 13

27.1
Connecting

240
Wire Hole
(39×27)

66.3
550

Liquid pipe: ø6.35 (flared) 1/4 B unit

710
51 51 51

Gas pipe : ø9.52 (flared) 3/8 connection Liquid pipe : ø6.35(flared)1/4 C unit
251.1

Gas pipe : ø9.52(flared)3/8 connection


280

Liquid pipe: ø6.35 (flared) 1/4 A unit


Liquid pipe : ø6.35(flared)1/4 B unit

225
440
Gas pipe : ø9.52 (flared) 3/8 connection

360
Gas pipe : ø9.52(flared)3/8 connection

45
Liquid pipe : ø6.35(flared)1/4 A unit
Gas pipe : ø9.52(flared)3/8 connection

84
10

302.5 170.4

150 500 299 23.1

800 69

MXZ- 4D72VA MXZ-4D83VA MXZ-5D102VA


OUTDOOR UNIT OUTDOOR UNIT

169 500 171 200 500 200


2-U Shaped notched hole
65.4 207.5 314 315
(Fondation bolt M10)
17.7

16
27

Air in
42
34
16.6

11
18.3

(Bolt pitch)
(Bolt Pitch)

355
360.6

387
396

Air in Air in
24
12.3

Air out
16
17.7

40

Air out Drain hole 42 2-12×36 Oval hole


Drain hole 3-ø33
4-10×21 Oval hole (Foundation bolt M10)
(Foundation bolt M8)

840 30 900 25 320 10


25.8 330 13
200
Handle
Indoor and
outdoor
Connecting connect wiring
Wire Hole (35×53) hole
240

27.1 (39×27) 66.3


Handle
88
Liquid pipe : Ø6.35(flared)1/4 D unit Liquid pipe : Ø6.35(flared)1/4 E unit connection
Gas pipe : Ø9.52(flared)3/8 connection Gas pipe : Ø9.52(flared)3/8 (MXZ-5D102VA)
710

915

Liquid pipe : Ø6.35(flared)1/4 C unit Liquid pipe : Ø6.35(flared)1/4 D unit connection


Gas pipe : Ø9.52(flared)3/8 connection Gas pipe : Ø9.52(flared)3/8
315
440

405

Liquid pipe : Ø6.35(flared)1/4 B unit Liquid pipe : Ø6.35(flared)1/4


C unit connection
612
360

Gas pipe : Ø9.52(flared)3/8


45

Gas pipe : Ø9.52(flared)3/8 connection


Liquid pipe : Ø6.35(flared)1/4
475

Liquid pipe : Ø6.35(flared)1/4 B unit connection


45

A unit Gas pipe : Ø9.52(flared)3/8


Gas pipe : Ø12.7(flared)1/2 connection
Liquid pipe : Ø6.35(flared)1/4
A unit connection
84

Gas pipe : Ø12.7(flared)1/2


147

299 23.1

317 23

117

P099-118.indd 117 13.12.12 1:24:01 PM


Unit : mm
MXZ-6C122VA MXZ-8B140VA MXZ-8B140YA
OUTDOOR UNIT MXZ-8B160VA MXZ-8B160YA
OUTDOOR UNIT
200 500 200 2-U Shaped Notched Hole
(Foundation Bolt M10)
450
Rear Air Rear air intake
27
16
48

Intake 2 U-shaped notched holes


(Foundation Bolt M10)
11

175 600 175


(Bolt Pitch) Installation Feet

19
355

Side Air Intake 387


24

Side air intake

330

417
370
Air
16

42 Drain Hole
40

37
56
Discharge

2-12 x 36 Oval Hole


(Foundation Bolt M10)

30
56 42

28
53
Air discharge 2-12 x 36 Oval holes
(Foundation Bolt M10)
900 21 320 5

950 Terminal connection

Connecting
Wire Hole
Handle for moving
322
Earth terminal ( Left .... Power supply wiring
Right..Indoor/Outdoor wiring )
(36 x 96)
Handle

70
Handle LIQ
Unit F
GAS
LIQ
1070

Unit E
GAS
65

LIQ
Unit D
GAS LIQ 6.35(1/4")FLARE Service panel
515

LIQ GAS 9.52(3/8")FLARE


730

Unit C
GAS

1350
LIQ
548

Handle for moving

635
Unit B
45

GAS
LIQ LIQ 6.35(1/4")FLARE
Unit A GAS 12.7(1/2")FLARE
GAS
125

A
340 34
1

2
371

507
423
23

Front piping cover


Rear piping cover

...Refrigerant gas pipe connection (FLARE)


...Refrigerant liquid pipe connection (FLARE)
Indicates stop valve connection location

Model A
MXZ-8B140VA/160VA 1079
MXZ-8B140YA/160YA 930

PAC-AK53BC PAC-AK32BC
Suspension bolt pitch
320
Suspension bolt : W3/8 (M10) Suspension bolt pitch
Suspension bolt : W3/8 (M10) 320

Branch box Branch box


Suspension bolt pitch

Suspension bolt pitch


402

402
24

24

12
12

450 91 95 280 39
73 450 91 95 280 39
55 61 79 50 34 3-Electric wire inlet
to indoor unit 205 73 61 79 50 34 3-Electric wire inlet
to indoor unit
39

70

39

E D C B A
70

C B A
65

E D C B A
198

35

65

C B A
35
198
68

68

3-Wire band
25 25 25 25 25 21 to outdoor unit 3-Wire band
Electric cover
25 25 25 21
75 75 75 75 200 Service panel to outdoor unit Electric cover
23 (for Lev, thermistor) 75 75 200 Service panel
23 (for Lev, thermistor)
Type A
Type A
Flexible drain hose Drain pipe connection
20

(accessory) (VP-16)
20

Flexible drain hose Drain pipe connection


(accessory) (VP-16)
200
200
Type B
Type B
20

Flexible drain hose Drain pipe connection


(accessory) (VP-16)
20

Flexible drain hose Drain pipe connection


(accessory) (VP-16)

118

P099-118.indd 118 13.12.12 1:24:01 PM


Piping Installation

Single type
Maximum Piping Length(m) Maximum Height Difference(m) Maximum Number of Bends
Series Class
<Outdoor unit> Total length(A) Outdoor unit - Indoor unit(H) Total number
MSZ-F 25 / 35 20 12 10
MFZ-KJ 15
50 30 10
MSZ-E 25 / 35 / 42 20 12 10
50 30 15 10
MSZ-S 25 / 35 / 42 20 12 10
50 30 15 10
MSZ-G 60 / 71 30 15 10
MSZ-H 25 / 35 / 50 20 12 10

&
Single type
Maximum Piping Length(m) Maximum Height Difference(m) Maximum Number of Bends
Series Class
<Outdoor unit> Total length(A) Outdoor unit - Indoor unit(H) Total number
ZUBADAN (PUHZ-SHW) 80 / 112 / 140 75 30 15
POWER INVERTER (PUHZ-ZRP/ RP) 35 / 50 / 60 / 71 50 30 15
100 / 125 / 140 75 30 15
200 / 250 100 30 15
STANDARD INVERTER 25 / 35 20 12 10
(PUHZ-P & SUZ) 30
50 / 60 / 71 30 10
100 / 125 / 140 50 30 15
200 / 250 70 30 15

Twin type
Maximum Piping Length(m) Maximum Height Difference(m) Maximum Number of Bends
Class Pipe length difference Indoor unit - Outdoor unit - Indoor unit -
Series Total length
<Outdoor unit> from distribution pipe Distribution pipe Indoor unit Indoor unit Total number
A+B+C |B-C| B H h
ZUBADAN (PUHZ-SHW) 80 / 112 / 140 75 8 20 30 1 15
POWER INVERTER (PUHZ-ZRP/ RP) 71 50 8 20 30 1 15
100 / 125 / 140 75 8 20 30 1 15
200 / 250 120 8 30 30 1 15
STANDARD INVERTER (PUHZ-P) 100 / 125 / 140 50 8 20 30 1 15
200 / 250 70 8 30 30 1 15

Triple type
Maximum Piping Length(m) Maximum Height Difference(m) Maximum Number of Bends
Class Pipe length difference Indoor unit - Outdoor unit - Indoor unit -
Series Total length
<Outdoor unit> from distribution pipe Distribution pipe Indoor unit Indoor unit Total number
A+B+C+D |B-C| B H h
POWER INVERTER (PUHZ-ZRP/ RP) 140 75 8 20 30 1 15
200 / 250 120 8 30 30 1 15
STANDARD INVERTER (PUHZ-P) 140 50 8 20 30 1 15
200 / 250 70 8 28 30 1 15

Quadruple type
Maximum Piping Length(m) Maximum Height Difference(m) Maximum Number of Bends
Class Pipe length difference Indoor unit - Outdoor unit - Indoor unit -
Series <Outdoor unit > Total length
from distribution pipe Distribution pipe Indoor unit Indoor unit Total number
A+B+C+D+E |B-C| B H h
POWER INVERTER (PUHZ-RP) 200 / 250 120 8 30 30 1 15
STANDARD INVERTER (PUHZ-P) 200 / 250 70 8 22 30 1 15

Single type Twin type Total length A+B+C Triple type Total length A+B+C+D Quadruple type Total length A+B+C+D+E

Farthest & Highest Farthest & Highest

B Closest
& Lowest D Closest
& Lowest
C h
h B h D
B
C E
Distribution H
H H H C
pipe
Distribution Distribution
A A pipe A pipe A

119

P119-124.indd 119 13.12.12 1:24:50 PM


MXZ-2D33VA
Indoor a Maximum height
Maximum Piping Length units difference
Outdoor unit - Indoor unit (a,b) 15m
Total length (a+b) 20m
Outdoor Outdoor unit
|

unit Indoor unit


Maximum Number of Bends 10m
*Outdoor unit
Outdoor unit - Indoor unit (a,b) 15 installed lower Indoor unit
|
Indoor unit
Total number (a+b) 20 10m

Outdoor unit
|
Indoor unit
b
10m
*Outdoor unit
installed higher

MXZ-2D42VA
Maximum Piping Length Indoor a Maximum height
units difference
Outdoor unit - Indoor unit (a,b) 20m
Total length (a+b) 30m
Outdoor unit
Outdoor |
Maximum Number of Bends unit Indoor unit
15m
Outdoor unit - Indoor unit (a,b) 20 *Outdoor unit
installed lower Indoor unit
|

Total number (a+b) 30 Indoor unit


15m

Outdoor unit
MXZ-2D53VA(H) |
Indoor unit
b 10m
Maximum Piping Length *Outdoor unit
installed higher
Outdoor unit - Indoor unit (a,b) 20m
Total length (a+b) 30m

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b) 20
Total number (a+b) 30

Highest
MXZ-3D54VA2 Indoor Maximum height
Maximum Piping Length units a
difference
Outdoor unit - Indoor unit (a,b,c) 25m
Total length (a+b+c) 50m
b Outdoor Outdoor unit
|
unit Indoor unit
Maximum Number of Bends 15m
*Outdoor unit
Outdoor unit - Indoor unit (a,b,c) 25 installed lower
Indoor unit
Total number (a+b+c) 50 |
Indoor unit
15m
Outdoor unit
MXZ-3D68VA Lowest
|
Indoor unit
c
Maximum Piping Length 10m
*Outdoor unit
installed higher
Outdoor unit - Indoor unit (a,b,c) 25m
Total length (a+b+c) 60m

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c) 25
Total number (a+b+c) 60

120

P119-124.indd 120 13.12.12 1:24:51 PM


MXZ-4D72VA
Indoor
Maximum Piping Length units Highest Maximum height
Outdoor unit - Indoor unit (a,b,c,d) 25m a difference
Total length (a+b+c+d) 60m

b Outdoor
Maximum Number of Bends unit Outdoor unit
|
Indoor unit
Outdoor unit - Indoor unit (a,b,c,d) 25 15m
*Outdoor unit
Total number (a+b+c+d) 60 installed lower Indoor unit
|

c Indoor unit
15m

Outdoor unit
MXZ-4D83VA Lowest d
|
Indoor unit
Maximum Piping Length 10m
*Outdoor unit
installed higher
Outdoor unit - Indoor unit (a,b,c,d) 25m
Total length (a+b+c+d) 70m

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c,d) 25
Total number (a+b+c+d) 70

Indoor Maximum height


MXZ-5D102VA units Highest
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e) 25m
Outdoor
Total length (a+b+c+d+e) 80m b unit
Outdoor unit
|
Indoor unit
Maximum Number of Bends c 15m
*Outdoor unit
Outdoor unit - Indoor unit (a,b,c,d,e) 25 installed lower Indoor unit
|
Indoor unit
Total number (a+b+c+d+e) 80 15m
Outdoor unit
|
Lowest Indoor unit
10m
d e
*Outdoor unit
installed higher

Highest
Indoor e Maximum height
MXZ-6C122VA units
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25m
Outdoor
Total length (a+b+c+d+e+f) 80m b unit Outdoor unit
|
Indoor unit
15m
Maximum Number of Bends c *Outdoor unit
installed lower Indoor unit
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25 |
Indoor unit

Total number (a+b+c+d+e+f) 80 15m

Outdoor unit
|
Lowest Indoor unit
10m
d f
*Outdoor unit
installed higher

121

P119-124.indd 121 13.12.12 1:24:51 PM


MXZ-8B140VA / YA, 8B160VA / YA

b2 Farther
b1
& Lower
Closer
B
& Higher B h2 I
H
h1 a1
a5 a6 a7 a8
a2 a3 a4
Lowest C
C C C C C A Outdoor unit
C B Branch box
h3 C Indoor unit

C Farthest & Highest

Total length b1 + b2 + a1+ a2 + a3 + a4 + a5 + a6 + a7 + a8 115m


Maximum Outdoor unit - Branch box - b2 + a8 70m (b2 55m, a8 15m)
Piping Length Indoor unit (L)

Outdoor unit - Branch box b1 + b2 55m

Branch box - Indoor unit (I) a8 15m


Total pipe length after the branch box a1+ a2 + a3 + a4 + a5 + a6 a7 + a8 60m
Outdoor unit - Indoor unit (H) 1 H 30m (when outdoor unit is set higher than indoor unit)
Maximum Height H 20m (when outdoor unit is set lower than indoor unit)
Difference
Branch box - Indoor unit (h1) h1 + h2 15m
Branch box - Branch box (h2) h2 15m
Indoor unit - Indoor unit (h3) h3 12m
Maximum Number Total number | b1 + a1 |,| b1 + a2 |,| b1 + a3 |,| b1 + a4 |,| b1 + a5 |,| b2 + a6 |,
of Bends | b2 + a7 |,| b2 + a8 | 15
1 Branch box should be placed on a plane between the outdoor unit and indoor units.

122

P119-124.indd 122 13.12.12 1:24:51 PM


Explanation of Terminology
Maximum piping length:
This is the maximum allowable length of the refrigerant piping. The amount of refrigerant pipe used cannot be longer than the
length specified.

Total length:
The maximum allowable combined length of all the refrigerant piping between the outdoor unit and indoor unit(s).

Outdoor Unit - Indoor Unit:


The maximum allowable length of the refrigerant piping between the outdoor unit and indoor units installed when multiple units are connec-
ted to a single outdoor unit. This distance limitation refers to the maximum length between the outdoor unit and the farthest indoor unit.

Pipe length difference from distribution pipe:


The maximum allowable difference in refrigerant piping length from the distribution pipe to the farthest indoor unit and from the distribution
pipe to the closest indoor unit when multiple indoor units are connected to a single outdoor unit using a distribution pipe.

Indoor Unit - Distribution Pipe:


The maximum allowable length of the refrigerant piping between indoor units and the distribution pipe when multiple indoor units are
connected to a single outdoor unit.

Outdoor unit - Branch box:


The maximum allowable length of the refrigerant piping between the branch box and outdoor unit when a branch box is used to connect
multiple indoor units to a single outdoor unit.

Branch box - Indoor unit:


The maximum allowable length of the refrigerant piping between the branch box and the indoor unit farthest from it when a branch box
is used to connect multiple indoor units to a single outdoor unit.

Outdoor unit - Branch box - Indoor unit:


The maximum allowable length of the refrigerant piping from the outdoor unit to the farthest indoor unit when a branch box is used to
connect multiple indoor units with a single outdoor unit.

Total pipe length after the branch box:


The maximum allowable length of the refrigerant piping between the branch box and all indoor units combined when a branch box is used
to connect multiple indoor units with a single outdoor unit.

Maximum height difference:


This is the maximum allowable height difference. It is necessary to install the air conditioning system so that the height distance
is no more than the difference specified. (Specified differences may vary if the outdoor unit is installed higher or lower than the
indoor units).

Outdoor unit - Indoor unit:


The maximum allowable difference in height between the outdoor unit and indoor units when installed (when multiple indoor units are con-
nected to a single outdoor unit, this distance limitation refers to the maximum height difference between the outdoor unit and an indoor unit).

Indoor unit - Indoor unit:


The maximum allowable difference between the heights of indoor units when multiple indoor units are connected to a single outdoor unit.

Branch box - Indoor unit:


The maximum allowable difference between the heights of the branch box and an indoor unit when multiple indoor units are connected
to a single outdoor unit.

Branch box - Branch box:


The maximum allowable difference between the heights of the branch boxes when two branch boxes are used to connect multiple indoor
units to a single outdoor unit.

Maximum number of bends:


This is the maximum allowable number of bends in the refrigerant piping. The total number of bends in the refrigerant piping
used cannot exceed the number specified.

Total number:
The maximum allowable number of bends for all refrigerant piping between the outdoor unit and indoor units.

Outdoor unit - Indoor unit:


The maximum allowable number of bends between the outdoor unit and each indoor unit when multiple indoor units are connected
to a single outdoor unit.

123

P119-124.indd 123 13.12.12 1:24:51 PM


124

P119-124.indd 124 13.12.12 1:24:51 PM


125

P125-138.indd 125 13.12.12 1:25:36 PM


ECODAN
“ecodan” can heat rooms and supply domestic
hot water, realising greater comfort and energy saving.
“ecodan” – Economic, eco conscious next generation heating system
Both energy-saving and safe for the environment, the Mitsubishi Electric ecodan incorporates a highly efficient heat pump
system that captures “the heat in the air”, a renewable energy resource. Equipped with advanced inverter control, meticulous
temperature control assures comfortable heating, and its space-saving “All-in-one” indoor unit is easy to install. These energy-
saving, high comfort and simple installation characteristics have drawn the ecodan heating system into the spotlight centre
stage.

Excellent ecodan’s heating performance, even at low outdoor temperature!

INDOOR UNIT

Cylinder unit Hydro box Hydro box


(Reversible)

EHSC/EHPX
ERSC

EHST20C/EHPT20X

OUTDOOR UNIT

Split type Packaged type

SHW230 SW100/120 SW75 SW40/50 HW112/140 W85 W50

126

P125-138.indd 126 13.12.12 1:25:37 PM


Unique technology of ecodan
Auto Adaptation Settings can be
performed using
an SD card.
ecodan – Maximize energy savings while keeping comfort at all times
Aiming to realise further comfort and energy savings, Mitsubishi Electric is proud to introduce a ■ Heat curve setting (Example)
revolutionary new system control. This is based on data indicating that a 1°C drop in the flow tem- Flow temp.
perature improves the coefficient of performance (COP) of the ATW system by 2%. This means
that energy savings are dramatically affected by controlling the flow temperature in the system. If flow
60°C temperature is COP is
In conventional system control, the flow temperature is determined based on the preset heat lowered 1°C improved 2%

curve depending on the actual outdoor temperature. However, this requires a complicated set-
30°C
ting to achieve the optimal heat curve.
-15°C 10°C Outdoor temp.
Mitsubishi Electric’s Auto Adaptation function automatically tracks changes
of the actual room temperatures and outdoor temperatures and adjusts the flow temperature accordingly.
Our more evolutionary Auto Adaptation function measures the room temperature and outdoor temperature, and then calculates the required heating
capacity for the room. Simply stated, the flow temperature is automatically controlled according to the required heating capacity, while optimal room
temperature is maintained at all times, ensuring the appropriate heating capacity and preventing energy from being wasted. Furthermore, by
estimating future changes in room temperature, the system works to prevent unnecessary increases and decreases in the flow temperature.
Accordingly, Auto Adaptation maximises both comfort and energy savings without the need for complicated settings.

■ Two Controls simulation on a day Temperature/


Curtain Ventilation fan Increase in Lights
Heating Load turned on occupants turned off
opened

1 Room temperature slightly increases Changes in room conditions

2 Flow temperature decreases Flow temp.


4
Energy savings
3 Room temperature decreases 2
Room temp.
Temperature
4 Flow temperature slightly increases setting
Comfort
3
The flow temperature through the system controlled 1
via conventional heat curve
The flow temperature through the system controlled Outdoor temp.
via Mitsubishi Electric’s Auto Adaptation function
6:00 12:00 18:00 24:00 Time

■ Future room temperature estimation Room temp.


(a) Higher than the target room temp. lower the flow temp.

Target temp. (b) Approximately same as the target temp. keep the flow temp.

(c) Lower than the target room temp. raise the flow temp.

Modify the flow temperature by comparing


actual and estimated room temperature.

3 points T0 T1 Current Future Time

All-in-one & compact


Small overall size contributes to easy transportation, installation and maintenance
• Simplified: All key functional components are incorporated into the unit.
• Easy servicing: Relevant parts are located at the front of the unit to Compact cylinder unit
access easily.
MANOMETER
• Easy to transport and install using the attached handle both at front *EXPANSION VESSEL
and at back (cylinder unit) and also back plate (hydro box unit). (behind)
HANDLES (back)
• Easy to open the packaging without using knife.
CONTROL AND
ELECTRICAL BOX MAIN REMOTE
Compact hydro box unit CONTROLLER
*EXPANSION VESSEL 3-WAY VALVE

CONTROL AND
ELECTRICAL BOX PUMP VALVE
WATER PUMP

TANK
BOOSTER HEATER *PLATE HEAT
*PLATE HEAT
EXCHANGER
EXCHANGER BOOSTER HEATER
PUMP VALVE
STRAINER *IMMERSION
WATER PUMP MAIN REMOTE HEATER
CONTROLLER
FLOW SWITCH
STRAINER
MANOMETER
FLOW SWITCH (behind) ADJUSTER HANDLE
PRESSURE RELIEF VALVE (behind) *Depending on model

127

P125-138.indd 127 13.12.12 1:25:39 PM


Designed for Optimal Heating
ZUBADAN New Generation (Split type)
Improved heating performance more efficiently
ZUBADAN is equipped with a unique “Flash Injection
Approx. 22% higher than Nominal capacity can be
Circuit” that enables the system to provide powerful our previous model ! kept at -15°C !
heating in cold regions during the winter months. And
more evolved “ZUBADAN New Generation” incorporates 15
ZUBADAN New Generation
a new compressor that is more efficient, further improving 14

capacity (kW)
13

Integrated
heating performance when outdoor temperatures is low.
12
The rated heating capacity can now be maintained at
11
-15°C even including defrost, making it possible to supply
10
comfortable heating in ever more severe environments. ZUBADAN
9

-25°C -20°C -15°C -7°C 0°C


Outdoor-air temperature at intake duct
W45 (according to EN 14511)

Ideal for
A-15/W55 DHW!
65
possible! ZUBADAN New Generation
flow temp. (deg C)

60
Max. possible

55

50

45

40
-20°C -15°C -10°C -5°C -0°C 5°C 10°C
Outdoor temp.

Mitsubishi Electric’s Flash Injection Technology


The Key to High Heating Performance at Low Outdoor Temperatures

■ Flash Injection Circuit


ZUBADAN New Generation
Injection compressor
(injection port)
Flash Injection Circuit

A
Indoor Outdoor
Power Heat Interchanger (HIC)
HEX HEX
receiver
B
LEV B LEV A

LEV C
A Heat B
interchanger Injection Compressor
Refrigerant (HIC)
flow
Flash Injection Circuit

The Flash Injection Circuit is an original technology developed by Mitsubishi Electric. A heat exchange process at point A (heat interchanger)
transforms liquid refrigerant into a two-phase, gas-liquid state and then compresses the gas-liquid refrigerant at point B (injection compressor).
This circuit secures a enough flow rate of refrigerant for heating when outdoor temperatures are very low.
In the ZUBADAN New Generation, the Flash Injection Circuit is more powerful by improving the heat interchanger to increase the heat-
exchange-efficiency and incorporating new injection compressor to increase the compression-efficiency.
These two improvements of ZUBADAN New Generation ensure reliable, efficient heating operation when outdoor temperatures are very low.

128

P125-138.indd 128 13.12.12 1:25:39 PM


SD* CARD
*SD logo is a trademark of SD-3C, LLC
Settings can be
performed using
an SD card.
The ecodan evolution continues! For easier settings and for data loggings
Initial setting for ecodan is now simpler than ever before. The special software enables the required initial settings to be saved to an SD card
using a personal computer. System set-up is as easy as moving the SD card from the computer to the SD card slot in the indoor unit. Compared
to the previous procedure of inputting settings using the main controller at a installation field, a remarkable reduction in set-up time has been
achieved. Thus, it is ideal way for busy installers.
*SD card fanction is only used by installer.

Hydro box inside Settings can be performed easily and


logging operation data in SD card
can be confirmed via personal computer.
Printed circuit board

Control and electric box SD card slot SD card SD card

Items that can be preset Data that can be stored


Simply copying the preset data to SD card, Operation data up to a month long can be stored on
same settings are complete in multiple units easily. a SD card (2GB) .
• Initial settings (time display, contact number, etc) • Operation time
• Heating settings • Defrost time
- Auto Adaptation • Actual temperature
- Heat curve - Room
- Two different temperatures zones - Flow temperature
• Interlocked boiler operation settings - Return temperature
• Holiday mode settings - Domestic hot water temperature
• Schedule timer settings - Outdoor temperature
• Domestic hot water settings • Error record
• Legionella prevention settings • Input signal etc.
All items that are set by the main controller can be set via
a personal computer.

Remote controller
Stylish, easy-to-read bright LCD with ergonomically designed intuitive interface
Main controller
• Large screen and backlight for excellent visibility, even in dark environment
• Multilanguage support (11 languages)
• Can be removed from main unit and installed in remote location (up to 500m)
• Wide range of convenient functions in response to user demand
Functions settings
- Weekly timer -Holiday mode -Legionella prevention -Error codes and data for serving
NEW - Two zone control -Boiler interlock -Floor drying up
• Quick reading of operation data (7.5 times faster than previous model) Main controller

Wireless remote controller (optional)


• Built-in room temperature sensor; easy to place in the best position to detect room temperature
• Wiring work eliminated
• Simple design that is easy to operate
• Remote control from any room without needing to choose an installation location
• Backlight and big buttons that are easy to operate
• Domestic hot water boost and cancellation PAR-WR51R-E (optional) PAR-WT50R-E (optional)
• Simplified holiday mode Receiver Wireless remote controller
• Up to 8 controllers allowed (can be set for zone 1 or 2 individually)

129

P125-138.indd 129 13.12.12 1:25:40 PM


Two zone control
Settings can be
Simultaneously making two different temperature zones performed using
an SD card.
assures more comfortable, highly convenient heating
ecodan makes it possible to set two temperatures which are used in two different types heat emitters in a system. The system allows
adjustment of temperatures when different room temperatures are required, such as a temperature of 40°C for the living room radiator and
temperature of 30°C for floor heating. Additionally, the scheduling for each zone can be set separately by main controller.

■ Two temperature zones

40°C
Hydro box Radiator
Pump
Mixing control
Mixing Flow switch
FTC* valve

Pump
30°C

Mixing tank Flow switch Underfloor heating

*FTC = Flow temperature controller *Items such as mixing tank, mixing valve, flow switch and pumps are not included and need to be purchased locally.

Intelligent boiler interlock


No need to replace existing boiler! Settings can be
performed using
an SD card.
Automatic switchover enables even more efficient operation
The flexibility of ecodan’s intelligent control allows the system to be combined with boiler currently in use. Additionally, this control can judge
which heating source (ecodan, or boiler) to be operated according to situations (outdoor temperature, running cost, CO 2 emission level etc.).
Customers using a boiler can receive the energy-saving performance of ecodan.

Intelligent system combining a boiler with ecodan


Room temperature
■ Two temperature zones Hydro box wireless remote controller (option)

FTC
*Thermostat (field supply) also can be used.
Electricity

Radiator Radiator
Turning boiler on/off
according to operational Pump
conditions.

Other source
(Gas, Oil, etc) Mixing tank

Boiler *Items such as mixing tank and pump are not included and need to be purchased locally.

Multiple unit control


Connect up to 6 units Settings can be
performed using
an SD card.
Automatic control of multiple units to supply bigger capacity
A maximum of 6 ecodan units* can be configured ■ Multiple unit control
COP ratio (%)
according to the required heating/cooling load of the 1 unit 2 units 3 units 4 units 5 units 6 units
100
building. The most efficient number of operating units is
determined automatically based on heating/cooling
load. This enables ecodan to provide optimal room Always high efficient operation !
Inefficient operation Multiple unit control
temperature control, and thus superior comfort for ON/OFF control at low capacity. One large unit control

room occupants. Also incorporated is a rotation function Total Capacity

that works to balance the running hours without


depending on the operation of any one specific unit.

If one of the units malfunctions when using Multiple 14 kW + 14 kW + 14 kW + 14 kW + 14 kW + 14 kW


Unit Control, another unit can be automatically operated
for back-up, thereby preventing system operation from
stopping completely. FTC
slave
FTC
slave
FTC
slave
FTC
slave
FTC
slave
FTC
slave

*Only same models (same capacity) are available.

Multiple unit control


FTC
master
Main RC

130

P125-138.indd 130 13.12.12 1:25:41 PM


Split type specifications

Indoor unit
<Cylinder unit>
Model name EHST20C-VM6HB EHST20C-YM9HB EHST20C-TM9HB EHST20C-VM2B EHST20C-VM6B EHST20C-YM9B EHST20C-VM6EB EHST20C-YM9EB EHST20C-VM6SB
Type Heating only
Immersion heater × × × - - - - - -
Expansion vessel × × × × × × - - ×
Solar circuit - - - - - - - - ×
Dimensions H×W×D mm 1600×595×680
Product weight (empty) kg 128 128 128 125 127 127 122 122 128
Type of installation - Floor standing
Power supply (V / Phase / Hz) 230/Single/50
Heater Booster Power supply (V / Phase / Hz) 230/Single/50 400/Three/50 230/Three/50 230/Single/50 230/Single/50 400/Three/50 230/Single/50 400/Three/50 230/Single/50
heater
Capacity kW 6 (2/4/6) 9 (3/6/9) 9 (3/6/9) 2 6 (2/4/6) 9 (3/6/9) 6 (2/4/6) 9 (3/6/9) 6 (2/4/6)
Current A 26 13 23 9 26 13 26 13 26
Breaker A 32 16 30 16 32 16 32 16 32
Immersion Power supply (V / Phase / Hz) 230/Single/50 230/Single/50 230/Single/50 - - - - - -
heater
Capacity kW 3 3 3 - - - - - -
Current A 13 13 13 - - - - - -
Breaker A 16 16 16 - - - - - -
Domestic Volume (net) L 200
hot water tank
Material - Stainless steel
Operating ambient condition* °C 0~35
Target Heating Room temperature °C 10~30
temperature
Flow temperature °C 25~60
range
DHW °C 40~60
Legionella prevention °C Max 70
Sound level (SPL) dB (A) 28

*The environment must be frost-free.

<Hydro box>
Model name EHSC-VM2B EHSC-VM6B EHSC-YM9B EHSC-TM9B EHSC-VM6EB EHSC-YM9EB ERSC-VM2B
Type Heating only Heating and Cooling
Expansion vessel × × × × - - ×
Dimensions H×W×D mm 800×530×360 860×530×360
Product weight (empty) kg 51 53 53 53 49 49 54
Type of installation - Wall mounted
Power supply (V / Phase / Hz) 230/Single/50
Heater Booster Power supply (V / Phase / Hz) 230/Single/50 230/Single/50 400/Three/50 230/Three/50 230/Single/50 400/Three/50 230/Single/50
heater
Capacity kW 2 6 (2/4/6) 9 (3/6/9) 9 (3/6/9) 6 (2/4/6) 9 (3/6/9) 2
Current A 9 26 13 23 26 13 9
Breaker A 16 32 16 32 32 16 16
Domestic Volume (net) L -
hot water tank
Material - -
Operating ambient condition*1 °C 0~35 0~35 0~35 0~35 0~35 0~35 0~35*2
Target Heating/ Room Heating °C 10~30
temperature Cooling temperature
Cooling °C - - - - - - N/A
range
Flow Heating °C 25~60
temperature
Cooling °C - - - - - - 5~25
DHW °C 40~60
Legionella prevention °C Max 70
Sound level (SPL) dB (A) 28
*1 The environment must be frost-free.
*2 Low outdoor temperature cooling is not allowed (minimum 10°C).

Outdoor unit
Model name PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
SW40VHA (-BS) SW50VHA (-BS) SW75VHA (-BS) SW100V/YHA (-BS) SW120V/YHA (-BS) SHW80VHA SHW112V/YHA SHW140YHA SHW230YKA*1 *2
Dimensions H×W×D mm 600×800×300 600×800×300 943×950×330 1350×950×330 1350×950×330 1350×950×330 1350×950×330 1350×950×330 1338×1050×330
Product weight kg 42 42 75 118 / 130 118 / 130 120 120/134 134 148
Power supply (V / Phase / Hz) VHA : 230/Single/50 YHA : 400/Three/50
Heating Capacity kW 4.10 6.00 8.00 11.20 16.00 8.00 11.20 14.00 23.00
(A7/W35)
COP 4.80 4.42 4.40 4.45 4.10 4.65 4.46 4.22 3.65
Power input kW 0.854 1.357 1.819 2.517 3.903 1.721 2.512 3.318 6.310
Heating Capacity kW 4.00 5.00 7.50 10.00 12.00 8.00 11.20 14.00 23.00
(A2/W35)
COP 3.24 2.97 3.40 3.32 3.24 3.55 3.34 2.96 2.37
Power input kW 1.235 1.684 2.206 3.009 3.704 2.254 3.354 4.730 9.690
Sound level (SPL) Heating dB (A) 45 46 51 54 54 51 52 52 59
Sound level (PWL) Heating dB (A) 62 63 69 70 72 69 70 70 76

Note: based on EN 14511 (Circulation pump input is not included.).


It may differ according to the system configuration.
*1 PUHZ-SHW230YKA can not be connected to ecodan indoor unit.
*2 The performance data is obtained when plate heat exchanger (ACH 70-40)×2 are connected.

131

P125-138.indd 131 13.12.12 1:25:42 PM


Optional parts
<Indoor unit>
Parts name Model name Specification Cylinder unit Hydro box
EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHSC- EHSC- EHSC- EHSC- EHSC- EHSC- ERSC-
VM6HB YM9HB TM9HB VM2B VM6B YM9B VM6EB YM9EB VM6SB VM2B VM6B YM9B TM9B VM6EB YM9EB VM2B
Wirelss remote controller PAR-WT50R-E × × × × × × × × × × × × × × × ×
Wirelss receiver PAR-WR51R-E × × × × × × × × × × × × × × × ×
Thermistors PAC-SE41TS-E For room temp. × × × × × × × × × × × × × × × ×
PAC-TH011-E For buffer and zone (flow and return temp.) × × × × × × × × × × × × × × × ×
PAC-TH011TK-E For tank temp. - - - - - - - - - × × × × × × ×
PAC-TH011HT-E For boiler (flow and return temp.) × × × × × × × × × × × × × × × ×
Immersion heater PAC-IH03V-E 1Ph 3kW - - - × × × × × × - - - - - - -
Joint pipe PAC-SH30RJ-E For PUHZ-SW40/50VHA (-BS) ø9.52 ø6.35 × × × × × × × × × × × × × × × ×
PAC-SH50RJ-E For PUHZ-SW40/50VHA (-BS) ø15.88 ø12.70 × × × × × × × × × × × × × × × ×
Wi-Fi INTERFACE PAC-WF010-E × × × × × × × × × × × × × × × ×

<Outdoor unit>
Parts name Model name Power inverter ZUBADAN
PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
SW40VHA(-BS) SW50VHA(-BS) SW75VHA(-BS) SW100V/YHA(-BS) SW120V/YHA(-BS) SHW80VHA SHW112V/YHA SHW140YHA SHW230YKA*1
Connector for drain hose heater signal output PAC-SE60RA-E × × × × × × × × ×
Air discharge guide PAC-SG58SG-E × × - - - - - - -
PAC-SG59SG-E - - × × × × × × -
PAC-SG96SG-E - - - - - - - - ×
Air protection guide PAC-SG56AG-E × × - - - - - - -
PAC-SH63AG-E - - × × × × × × -
PAC-SH95AG-E - - - - - - - - ×
Drain socket PAC-SG61DS-E - - × × × - - - -
PAC-SH71DS-E × × - - - - - - -
Centralised drain pan PAC-SG63DP-E × × - - - - - - -
PAC-SG64DP-E - - × × × - - - -
Control / Service tool PAC-SK52ST × × × × × × × × ×

*1 PUHZ-SHW230YKA can not be connected to ecodan indoor unit.

<Interface/Flow temperature controller>


Parts name Model name Description Power inverter ZUBADAN
PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
SW40VHA(-BS) SW50VHA(-BS) SW75VHA(-BS) SW100V/YHA(-BS) SW120V/YHA(-BS) SHW80VHA SHW112V/YHA SHW140YHA SHW230YKA
Capacity step control interface PAC-IF010-E*1 10 PC boards w/o case × *2 × *2 × *2 × *2 ×*2 × *2 × *2 × *2 × *2
PAC-IF011B-E 1 PC board w/ case × × × × × × × × ×
Flow temperature controllers PAC-IF020-E*1 10 PC boards w/o case × *2 × *2 × *2 × *2 × *2 × *2 × *2 × *2 × *2
PAC-IF021B-E 1 PC board w/ case × × × × × × × × ×
PAC-IF032B-E 1 PC board w/ case × × × × × × × × ×
System controllers PAC-IF051B-E 1 PC board w/ case × × × × × × × × ×
PAC-SIF051B-E 1 PC board w/ case × × × × × × × × ×
Thermistors PAC-TH011-E × × × × × × × × ×

*1 PAC-IF010-E and PAC-IF020-E are only for manufacturer’s preloading.


*2 PAC-TH011-E is required.

Contents
Parts name Model name Contents Q’ty Parts name Model name Contents Q’ty
Air discharge guide PAC-SG58SG-E Air discharge guide 1 Centralised drain pan PAC-SG63DP-E Centralised drain pan 1
Support (For the upper and lower sides) 2 PAC-SG64DP-E Centralised drain pan 1
Support (For right and left) 2 Control / Service tool PAC-SK52ST Control/Service Tool 1
Attachment screw (5×10) 4 Capacity step control PAC-IF010-E PC board 10*1
Attachment screw (4×10) 8 interface PAC-IF011B-E PC board 1
Spacer 4 Case 1
Air discharge guide PAC-SG59SG-E Air discharge guide 1 Thermistor 2
Attachment screw (5×35) 4 Flow temperature PAC-IF020-E PC board 10*1
Spacer 4 controllers PAC-IF021B-E PC board 1
PAC-SG96SG-E Air discharge guide 1 Case 1
Support 1 Thermistor 2
Screw (5×15) 12 Remote controller 1
Washer 12 Remote controller cable (5m) 1
Spring washer 12 PAC-IF032B-E PC board 1
Air protection guide PAC-SG56AG-E Front plate 1 Case 1
Side plate 2 Thermistor 3
Side plate 2 Remote controller 1
Connecting plate 2 Remote controller cable (5m) 1
Mounting screw (4×10) 14 System controllers PAC-IF051B-E PC board 1
Mounting screw (4×12) 4 Case 1
Washer (for screw 4×12) 4 Thermistor 2
PAC-SH63AG-E Air guide 1 Remote controller 1
Mounting screw (5×15) 4 Remote controller cable (10m) 1
Washer 4 SD memory card 1
Spring washer 4 PAC-SIF051B-E PC board 1
PAC-SH95AG-E Air guide 1 Case 1
Mounting screw (5×15) 6 Thermistor 2
Washer 6 Remote controller cable (10m) 1
Spring washer 6 SD memory card 1
Drain socket PAC-SG61DS-E Drain socket 1 Thermistors PAC-TH011-E Thermistor for buffer and zone (flow and return temp.) 20*2
Drain cap (ø33) 5 PAC-TH011HT-E Thermistor for tank temp. 20*2
Heat insulator 2 PAC-TH011TK-E Thermistor for boiler (flow and return temp.) 10*3
Band 8
PAC-SH71DS-E Drain socket 1
Drain cap (ø33/ø12) 7 *1 One carton contains 10 PC boards.
Heat insulator 2 *2 Two thermistors per package: 10 packages per carton
Band 8 *3 One thermistor per package: 10 packages per carton

132

P125-138.indd 132 13.12.12 1:25:43 PM


Packaged type specifications

Indoor unit
<Cylinder unit>
Model name EHPT20X-VM2HB EHPT20X-VM6HB EHPT20X-YM9HB EHPT20X-TM9HB EHPT20X-VM6B EHPT20X-YM9B
Type Heating only
Immersion heater × × × × - -
Expansion vessel × × × × × ×
Dimensions H×W×D mm 1600×595×680
Product weight (empty) kg 113 115 115 115 114 114
Type of installation - Floor standing
Power supply (V / Phase / Hz) 230/Single/50
Heater Booster heater Power supply (V / Phase / Hz) 230/Single/50 230/Single/50 400/Three/50 230/Three/50 230/Single/50 400/Three/50
Capacity kW 2 6 (2/4/6) 9 (3/6/9) 9 (3/6/9) 6 (2/4/6) 9 (3/6/9)
Current A 9 26 13 23 26 13
Breaker A 16 32 16 30 32 16
Immersion heater Power supply (V / Phase / Hz) 230/Single/50 230/Single/50 230/Single/50 230/Single/50 - -
Capacity kW 3 3 3 3 - -
Current A 13 13 13 13 - -
Breaker A 16 16 16 16 - -
Domestic Volume (net) L 200
hot water tank
Material - Stainless steel
Operating ambient condition* °C 0~35
Target Heating Room temperature °C 10~30
temperature
Flow temperature °C 25~60
range
DHW °C 40~60
Legionella prevention °C Max 70
Sound level (SPL) dB (A) 28

*The environment must be frost-free.

<Hydro box>
Model name EHPX-VM2B EHPX-VM6B EHPX-YM9B
Type Heating only
Expansion vessel × × ×
Dimensions H×W×D mm 800×530×360
Product weight (empty) kg 39 41 41
Type of installation - Wall mounted
Power supply (V / Phase / Hz) 230/Single/50
Heater Booster heater Power supply (V / Phase / Hz) 230/Single/50 230/Single/50 400/Three/50
Capacity kW 2 6 (2/4/6) 9 (3/6/9)
Current A 9 26 13
Breaker A 16 32 16
Domestic Volume (net) L -
hot water tank
Material - -
Operating ambient condition* °C 0~35
Target Heating Room temperature °C 10~30
temperature
Flow temperature °C 25~60
range
DHW °C -
Legionella prevention °C -
Sound level (SPL) dB (A) 28

*The environment must be frost-free.

Outdoor unit
Model name PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
W50VHA (-BS) W85VHA2 (-BS) HW112YHA2 (-BS) HW140VHA2 (-BS) HW140YHA2 (-BS)
Dimensions H×W×D mm 740×950×330 943×950×330 1350×1020×330 1350×1020×330 1350×1020×330
Product weight kg 64 79 148 134 148
Power supply (V / Phase / Hz) VHA : 230/Single/50 YHA : 400/Three/50
Heating Capacity kW 5.00 9.00 11.20 14.00 14.00
(A7/W35)
COP 4.10 4.18 4.42 4.25 4.25
Power input kW 1.220 2.153 2.533 3.294 3.294
Heating Capacity kW 5.00 8.50 11.20 14.00 14.00
(A2/W35)
COP 3.13 3.17 3.11 3.11 3.11
Power input kW 1.597 2.681 3.601 4.501 4.501
Sound level (SPL) Heating dB (A) 46 48 53 53 53
Sound level (PWL) Heating dB (A) 61 66 67 67 67

Note: based on EN 14511 (Circulation pump input is included.).


It may differ according to the system configuration.

133

P125-138.indd 133 13.12.12 1:25:43 PM


Optional parts
<Indoor unit>
Parts name Model name Specification Cylinder unit Hydro box
EHPT20X- EHPT20X- EHPT20X- EHPT20X- EHPT20X- EHPT20X- EHPX- EHPX- EHPX-
VM2HB VM6HB YM9HB TM9HB VM6B YM9B VM2B VM6B YM9B
Wirelss remote controller PAR-WT50R-E × × × × × × × × ×
Wirelss receiver PAR-WR51R-E × × × × × × × × ×
Thermistors PAC-SE41TS-E For room temp. × × × × × × × × ×
PAC-TH011-E For buffer and zone (flow and return temp.) × × × × × × × × ×
PAC-TH011TK-E For tank temp. - - - - - - × × ×
PAC-TH011HT-E For boiler (flow and return temp.) × × × × × × × × ×
Immersion heater PAC-IH03V-E 1Ph 3kW - - - - × × - - -
EHPT accessories for UK PAC-WK01UK-E × - - - - - - - -
Wi-Fi INTERFACE PAC-WF010-E × × × × × × × × ×

<Outdoor unit>
Parts name Model name Power inverter ZUBADAN
PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
W50VHA(-BS) W85VHA2(-BS) HW112YHA2(-BS) HW140VHA2(-BS) HW140YHA2(-BS)
Connector for drain hose heater signal output PAC-SE60RA-E × × × × ×
Air discharge guide PAC-SG59SG-E × × × × ×
Air protection guide PAC-SH63AG-E × × × × ×
Drain socket PAC-SG61DS-E × × - - -
Centralised drain pan PAC-SG64DP-E × × - - -

<Interface/Flow temperature control>


Parts name Model name Description Power inverter ZUBADAN
PUHZ- PUHZ- PUHZ- PUHZ- PUHZ-
W50VHA(-BS) W85VHA2(-BS) HW112YHA2(-BS) HW140VHA2(-BS) HW140YHA2(-BS)
Capacity step control interface PAC-IF010-E*1 10 PC boards w/o case × *2 × *2 × *2 × *2 × *2
PAC-IF011B-E 1 PC board w/ case × × × × ×
Flow temperature controllers PAC-IF020-E*1 10 PC boards w/o case × *2 × *2 × *2 × *2 × *2
PAC-IF021B-E 1 PC board w/ case × × × × ×
PAC-IF032B-E 1 PC board w/ case × × × × ×
System controllers PAC-IF051B-E 1 PC board w/ case × × × × ×
PAC-SIF051B-E 1 PC board w/ case × × × × ×
Thermistors PAC-TH011-E × × × × ×

*1 PAC-IF010-E and PAC-IF020-E are only for manufacturer’s preloading.


*2 PAC-TH011-E is required.

Contents
Parts name Model name Contents Q’ty Parts name Model name Contents Q’ty
Air discharge guide PAC-SG59SG-E Air discharge guide 1 System controllers PAC-IF051B-E PC board 1
Attachment screw (5×35) 4 Case 1
Spacer 4 Thermistor 2
Air protection guide PAC-SH63AG-E Air guide 1 Remote controller 1
Mounting screw (5×15) 4 Remote controller cable (10m) 1
Washer 4 SD memory card 1
Spring washer 4 PAC-SIF051B-E PC board 1
Drain socket PAC-SG61DS-E Drain socket 1 Case 1
Drain cap (ø33) 5 Thermistor 2
Heat insulator 2 Remote controller cable (10m) 1
Band 8 SD memory card 1
Centralised drain pan PAC-SG64DP-E Centralised drain pan 1 Thermistors PAC-TH011-E Thermistor for buffer and zone (flow and return temp.) 20*2
Capacity step control PAC-IF010-E PC board 10*1 PAC-TH011HT-E Thermistor for tank temp. 20*2
interface
PAC-IF011B-E PC board 1 PAC-TH011TK-E Thermistor for boiler (flow and return temp.) 10*3
Case 1
*1 One carton contains 10 PC boards.
Thermistor 2
*2 Two thermistors per package: 10 packages per carton
Flow temperature PAC-IF020-E PC board 10*1 *3 One thermistor per package: 10 packages per carton
controllers
PAC-IF021B-E PC board 1
Case 1
Thermistor 2
Remote controller 1
Remote controller cable (5m) 1
PAC-IF032B-E PC board 1
Case 1
Thermistor 3
Remote controller 1
Remote controller cable (5m) 1

134

P125-138.indd 134 13.12.12 1:25:43 PM


Mr.SLIM+
Using waste heat from air conditioners to heat water
Mr. SLIM+ – The smart air conditioning and hot-water supply
system conceived from eco-conscious ideas

INDOOR UNIT

PLA-ZRP71BA PKA-RP71KAL

PCA-RP71KA PCA-RP71HA

PSA-RP71KA

PEAD-RP71JAQ PEAD-RP71JALQ

ECODAN AIR-TO-WATER INDOOR UNIT OUTDOOR UNIT

Hydro box Cylinder unit

EHST20C-VM2B
EHST20C-VM6B
EHST20C-YM9B
EHSC-VM2B EHST20C-VM6EB
EHSC-VM6B EHST20C-YM9EB
EHSC-YM9B EHST20C-VM6SB
EHSC-TM9B EHST20C-VM6HB
EHSC-VM6EB EHST20C-YM9HB
EHSC-YM9EB EHST20C-TM9HB PUHZ-FRP71VHA

*2012 B generation split type models


*Reversible model cannot be connected

135

P125-138.indd 135 13.12.12 1:25:43 PM


More ecological
Heat recovery function recycles waste heat from air conditioners
Air conditioners normally exhaust hot air from the outdoor unit as waste heat in cooling operation. With Mr. SLIM+, however, the heat that is ex-
hausted by conventional air conditioning systems is recycled and simultaneously transferred to the hot-water supply system, where it’s used to heat
water.

In conventional systems, the air-heat exchanger in the outdoor unit works as a condenser during air conditioning operation.
The heat of the indoor-air is transferred to the outside-air and exhausted as waste heat.
The new circuit in Mr.SLIM+ uses a water-heat exchanger for supplying hot water as the condenser. When the air conditioning and hot-water sys-
tems are running at the same time, heat is recycled and used rather than being exhausted as waste heat.
“COP7.0* attained at water temperature of 45°C and standard air conditioning operation conditions”
Traditionally, when using a hot-water supply system where the air-heat exchanger is in the outdoor unit, operation may not be possible when the out-
side temperature is very high. However, since Mr.SLIM+ uses the Air-to-Air indoor unit for air conditioning operation and there’s no heat exchange
with outside-air,
it’s possible to use the hot-water supply system even if the ambient temperature is very high.
“Hot-water supply is possible (in heat recovery mode) even when the temperature outside is high (outside temperature = 46°C)”
*Conditions for Air-to-Air coolong: Indoor 27°C (dry bulb) / 19°C (wet bulb) ; Outdoor 35°C (dry bulb) *Water temperrature: 45°C

Space savings
Air conditioning and hot-water supply in one system – Installation space reduced
Mr.SLIM+ utilizes an evolutionary “2-in-1” design that combines
two original Mitsubishi Electric system technologies (i.e., Air-to- Conventional system
Air and Air-to-Water) using a single outdoor unit.
Save on installation
Mitsubishi Electric’s legendary Air-to-Air and Air-to-Water systems
have been integrated into a new configuration in which two sys-
tems share just one outdoor unit. The installation area required
outside is cut in half, realizing a space savings of 50%.

Save on construction
Previously, two systems including two separate outdoor units Hybrid heat recovery system
were required. But the all-new Mr.SLIM+ simplifies everything
into a single system configuration, improving reliability and quality
by reducing installation time. That results in savings in both time
and money, which are passed on to our customers.

136

P125-138.indd 136 13.12.12 1:25:44 PM


1 Unit, 2 Roles – Total Comfort Year-round
Air conditioning and hot-water supply matching the needs of each room
All-in-one outdoor unit
(air conditioning, hot-water supply and hot-water heating)
Mr.SLIM for Air-to-Air ecodan for Air-to-Water
Mr.SLIM+ utilizes a duct system that enables the air conditioning or heating of ✓ Hot-water supply (Domestic Hot-water supply)
multiple rooms, and other indoor unit type systems that is possible to fit vari- ✓ Hot-water heating for multiple rooms
ous applications.
Mr.SLIM+ utilizes ecodan system that is possible to make
Domestic Hot-water and to operate Hot-water heating.

Various operations

Mr.SLIM / Air to Air (Air Cooling) Mr.SLIM / Air to Air (Air Heating)

Air-to-Air cooling using Air-to-Air indoor unit Air-to-Air heating using Air-to-Air indoor unit

ecodan / Air to Water (Hot-water heating + DHW) Mr.SLIM + ecodan / Air to Air (Air Cooling) + DHW

Air-to-Water operation using Air-to-Water indoor unit Heat recovery using both Air-to-Air and Air-to-Water indoor units

137

P125-138.indd 137 13.12.12 1:25:44 PM


Specifications

Indoor unit PLA-ZRP71BA PKA-RP71KAL PCA-RP71KA PCA-RP71HA PSA-RP71KA PEAD-RP71JAQ PEAD-RP71JALQ


Outdoor unit PUHZ-FRP71VHA PUHZ-FRP71VHA PUHZ-FRP71VHA PUHZ-FRP71VHA PUHZ-FRP71VHA PUHZ-FRP71VHA PUHZ-FRP71VHA
Refrigerant R410A *1
Power supply Outdoor (V / Phase / Hz) 230 / Single / 50
Air-to-Air Cooling Capacity Rated kW 7.1 7.1 7.1 7.1 7.1 7.1 7.1
(ATA) Min-Max kW 3.3-8.1 3.3-8.1 3.3-8.1 3.3-8.1 3.3-8.1 3.3-8.1 3.3-8.1
Total input Rated kW 1.85 1.88 1.90 2.26 1.97 2.10 2.08
EER 3.84 3.78 3.74 3.14 3.60 3.38 3.41
Design load kW 7.1 7.1 7.1 7.1 7.1 7.1 7.1
Annual electricity consumption *2 kWh/a 382 393 387 462 408 459 441
SEER *4 6.5 6.3 6.4 5.4 6.1 5.4 5.6
Energy-efficiency class A++ A++ A++ A A++ A A+
Heating Capacity Rated kW 8.0 8.0 8.0 8.0 8.0 8.0 8.0
(average Min-Max kW 3.5-10.2 3.5-10.2 3.5-10.2 3.5-10.2 3.5-10.2 3.5-10.2 3.5-10.2
season)
Total input Rated kW 2.05 2.26 2.26 2.42 2.28 2.09 2.09
COP 3.90 3.54 3.54 3.14 3.33 3.83 3.83
Design load kW 4.7 4.7 4.7 4.7 4.7 4.9 4.9
Declared at reference design temperature kW 4.7 (–10°C) 4.7 (–10°C) 4.7 (–10°C) 4.7 (–10°C) 4.7 (–10°C) 4.9 (–10°C) 4.9 (–10°C)
capacity at bivalent temperature kW 4.7 (–10°C) 4.7 (–10°C) 4.7 (–10°C) 4.7 (–10°C) 4.7 (–10°C) 4.9 (–10°C) 4.9 (–10°C)
at operation limit temperature kW 3.5 (–20°C) 3.5 (–20°C) 3.5 (–20°C) 3.5 (–20°C) 3.5 (–20°C) 3.7 (–20°C) 3.7 (–20°C)
Back-up heating capacity kW 0 0 0 0 0 0 0
Annual electricity consumption *2 kWh/a 1,510 1,569 1,555 1,787 1,709 1,799 1,799
SCOP *4 4.4 4.2 4.2 3.7 3.9 3.8 3.8
Energy-efficiency class A+ A+ A+ A A A A
Air-to-Water Nominal flow rate (for heating) L/min 22.90
(ATW) Heating *5 A7W35 Capacity kW 8.00
Input kW 1.96
COP 4.08
A2W35 Capacity kW 7.50
Input kW 2.65
COP 2.83
Heat W45 Capacity (ATA cooling + ATW) kW 7.1+8.0 7.1+8.0 7.1+8.0 7.1+8.0 7.1+8.0 7.1+8.0 7.1+8.0
recovery Input kW 1.90 1.93 1.95 2.31 2.02 2.15 2.13
(ATA
cooling & COP 7.95 7.82 7.74 6.54 7.48 7.02 7.09
ATW) *6 W55 Capacity (ATA cooling + ATW) kW 7.1+9.0 7.1+9.0 7.1+9.0 6.4+9.0 7.1+9.0 7.1+9.0 7.1+9.0
Input kW 2.97 3.00 3.02 3.25 3.09 3.22 3.20
COP 5.42 5.37 5.33 4.74 5.21 5.00 5.03
ATW indoor unit Cylinder unit or Hydro box (see previous page)
Outdoor unit Dimensions HxWxD mm 943-950-330 (+30)
Weight kg 73 73 73 73 73 73 73
Air volume Cooling m3/min 55 55 55 55 55 55 55
Heating m3/min 55 55 55 55 55 55 55
Sound level (SPL) Cooling dB(A) 47 47 47 47 47 47 47
Heat recovery dB(A) 47 47 47 47 47 47 47
ATA Heating dB(A) 48 48 48 48 48 48 48
ATW Heating dB(A) 48 48 48 48 48 48 48
Sound level (PWL) Cooling dB(A) 67 67 67 67 67 67 67
Heat recovery dB(A) 67 67 67 67 67 67 67
ATA Heating dB(A) 68 68 68 68 68 68 68
ATW Heating dB(A) 68 68 68 68 68 68 68
Operating current (max) A 19.0 19.0 19.0 19.0 19.0 19.0 19.0
Breaker size A 25 25 25 25 25 25 25
Ext.piping Diameter Liquid/Gas mm 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88
Max.length Out-In m 30 (for ATA) + 30 (for ATW)
Max.height Out-In m 20 20 20 20 20 20 20
Guaranteed operating range Cooling *3 °C -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46 -15~+46
(outdoor) Heating °C -20~+21 -20~+21 -20~+21 -20~+21 -20~+21 -20~+21 -20~+21
ATW °C -20~+35 -20~+35 -20~+35 -20~+35 -20~+35 -20~+35 -20~+35
Heat recovery °C +15~+46 +15~+46 +15~+46 +15~+46 +15~+46 +15~+46 +15~+46

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) contributes less to global warming than a refrigerant with
higher GWP if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1,975. This means that if 1 kg of this refrigerant fluid leaked to
the atmosphere, the impact on global warming would be 1,975 times higher than that of 1 kg of CO2 over a period of 100 years. Never try to interfere with the refrigerant
circuit yourself or disassemble the product yourself; always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C.
*4 SEER/SCOP values are measured based on EN14825.
*5 Ait-to-Water values are measured based on EN14511 (Circulation pump input is not included.).
*6 Conditions for Air-to-Air cooling: Indoor 27°C (dry bulb) /19°C (wet bulb); Outdoor 35°C (dry bulb).

138

P125-138.indd 138 13.12.12 1:25:45 PM


SYSTEM

139

P139-149.indd 139 13.12.12 1:26:27 PM


SELECTION
A line-up of three product groups that addresses a wide range of needs.

SELECT LOSSNAY
Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

LGH SERIES LGH SERIES


Ceiling-concealed Ceiling-suspended 400m3/h
Nine models (150–2000m3/h)

LGH-15 to 100RX5-E • Applications: Stores, Schools, Etc.


• High/Low airflow control
• Can be controlled using separately sold mechanical
switches

VL SERIES
Wall-mounted 100m3/h

LGH-150 and 200RX5-E

• Applications: Offices, Stores, Etc.


• High total heat-exchange efficiency
• Excellent airflow control (Extra High, High, Low and Extra Low)
• Multi-ventilation Mode
• Can be interconnected with other Mitsubishi Electric • Application: Prefabricated offices (container houses),
air conditioners Residences, Etc.
• Exclusive Lossnay remote-control system • High/Low airflow control
• Mr. Slim remote controller can be used for some systems • Pull-string switch

SELECT OPTIONS
Remote controller (PZ-60DR-E) High-efficiency filter
120

Incorporation into the main unit


is simple, and filter changes can
130 19 be performed via the main unit
inspection opening.
Unit: mm

• 8-Language dot-matrix display Number


Model of filters Applicable model Filter material
• Weekly timer per set
PZ-25RFM 2 LGH-15RX5-E, LGH-25RX5-E
PZ-35RFM 2 LGH-35RX5-E Non combustible
Source power requirement Power received from a LOSSNAY unit,
TM4 PZ-50RFM 2 LGH-50RX5-E fiber
PZ-65RFM 2 LGH-65RX5-E (Polyester polyolefin)
Number of LOSSNAY units (EU-F7)
1–15 PZ-80RFM 2 LGH-80RX5-E, LGH-150RX5-E (2sets)
controlled by PZ-60DR-E
PZ-100RFM 2 LGH-100RX5-E, LGH-200RX5-E (2sets)

* Options listed above are exclusively for LGH-_RX5-E models.

140

P139-149.indd 140 13.12.12 1:26:28 PM


LOSSNAY
Lossnay ventilation systems are renowned industry-wide for their efficiency. They
offer environment-friendly energy recovery and humidity control, and enable air
SYSTEM

conditioning systems to simultaneously provide optimum room comfort and


energy savings.

One Adult Needs 400 Litres (Equivalent to Two Barrels) of Fresh Air Every Hour
In everyday life, occasionally there are times you might feel out of
● Oxygen density and deficiency disorders
breath, for example, when you’re in a closed room or a crowded Oxygen density (%)
train. This is because the air becomes carbon-rich; that is, the 0 5 10 15 20

carbon dioxide (CO2) that people exhale accumulates in closed


spaces, thereby increasing the carbon gas density. The average Normal air density 21%
person exhales about 20 litres of carbon-rich gas per hour. If there is
Safety limit 18%
no ventilation, the carbon gas density increases in the room as the
oxygen density decreases, and various problems could occur. To Increase in breath and pulse rate,
headaches, queasiness, nausea
16%
live comfortably, every person needs a surprising 400 litres of fresh
air per hour; a volume equivalent to two large barrels.
Dizziness, nausea, muscular
weakness (Potentially fatal)
12%

Main Gaseous Contaminants Found Indoors


Facial pallor,
unconsciousness, vomiting
10%

Contaminant Name
Chemical
Harm
Coma
(Death within 8 minutes)
8%
Formula

Carbon Monoxide CO Causes severe damage to the body


Respiratory arrest,
convulsions, death
6%
Sulfurous Gases Damages the body; causes asthma;
SO2
(sulfur oxide) reacts with metals, generates rusting
● Ventilation and Change in Amount of CO2 Exhaled
Direct harm to the body is unclear;
Nitrous Gases
becomes NO2 when bound with oxygen, (ppm)
Nitric oxide NO Window closed
causes indirect harm; irritates the throat 4000
Nitrogen dioxide NO2 3500
and lungs, possibly causing serious damage.
3000
2500
Carbon Dioxide Gas CO2 No direct harm unless the gas is very dense 2000
1500 Window open
Bad odours found inside residences do not 1000
Bad Odours — cause serious damage health-wise, but may 500
0
create discomfort
Before 1 2 After 10 20 30 40 50 60 70 80 90
smoking smoking
Source: An Introduction to Home Environment Studies. S. Fuji, Shoukokusha Publications Smoking time (min)

Ventilation Supporting Both Heating and Cooling


When using a ventilating system, indoor air that has been heated or
cooled escapes causing the room to become cold in winter or hot in
summer. As the heated/cooled air dissipates, the environment be-
comes uncomfortable, precious energy and money are wasted, and
the increasing amount of contaminated indoor air that needs to be Energy escapes during More energy used to maintain
ventilated turns into a major problem. The reason for this phenom- ventilation room temperature
enon is that heating/cooling and ventilation have an incompatible
relationship that is inversely proportional. For air conditioning,
Mitsubishi Electric proposes heating and cooling systems that
provide effective ventilation at the same time.

Ventilation becomes Facility maintenance costs


Heating/cooling results

necessary increase

Inverse relationship

Contamination occurs Ventilation is


sacrificed
Ventilation volume

141

P139-149.indd 141 13.12.12 1:26:28 PM


Simple Construction, High Performance – That’s Lossnay Air Ventilation
Simple Construction
As shown in the illustration, the Lossnay element design adopts a cross-flow shape Indoor Outdoor
and plate-fin construction that enables total heat exchange using specially pro- Indoor-air supply
(fresh heating/cooling air)
cessed paper dividers and interval plates. Since the dividers separate the intake and
exhaust passages, fresh air is always inducted without mixing with exhaust air. Divider Outdoor air outlet
(specially processed paper) (dirty indoor-air expelled)

Outdoor-air intake
(fresh air)

Indoor-air intake Interval plate


Operating Principle (dirty heating/cooling air) (specially processed paper)

The Lossnay element skillfully provides total heat exchange—temperature (i.e.,


sensible heat) and humidity (latent heat)—using specially processed paper dividers
and moisture permeability characteristics; enabling dirty indoor-air to be expelled
outside and fresh outdoor-air to be inducted inside, passing through the Lossnay
without ever mixing.
The principle can be explained by a simple experiment. Roll a sheet of paper into a
tube shape and blow through it. The warmth of the air is transferred to your hand,
and conversely, if cold air is blown through the tube, the coldness would be trans-
ferred to your hand. The same special properties of the paper are used for the
Lossnay total heat exchanger.

What are Sensible Heat and Latent Heat?


Sensible heat is the heat resulting from temperature changes (i.e., rise/fall) in a
substance, and latent heat is that which is generated or dissipates according to
changes in the state of a substance (e.g., evaporation, condensation, etc.).
● Temperature (sensible heat) exchange Thermal conduction and heat transfer
through the divider in all temperature ranges.
● Humidity (latent heat) exchange Water vapor transference through the divider
in all temperatures ranges based on differences in water vapor pressure.

Comfortable Air Ventilation Regardless of Being Hot or Cold


In summer In winter
Temperature difference between air supply and room: 1.7°C About 4kg/h of water vapor is recovered.

Supply air Supply air


LOSSNAY Conventional
ventilator LOSSNAY Conventional
ventilator
Dry bulb temperature (ºC) 27.7 33 Dry bulb temperature (ºC) 16 0
Absolute humidity (g/kg'(DA)) 13.4 20.1 Absolute humidity (g/kg'(DA)) 5.2 1.9
Relative humidity (%) 58 63 Exhaust air Relative humidity (%) 46 50 Exhaust air
Enthalpy (kJ/kg(DA)) 62.1 84.6 Enthalpy (kJ/kg(DA)) 29.2 4.7
Total heat recovered (kW) 7.5 0 Total heat recovered (kW) 8.2 0
Outdoor air load (kW) 3.1 10.6 Outdoor air load (kW) 3.1 11.3
Outdoor air load ratio (%) 29 100 Outdoor air load ratio (%) 27 100

Room air Outdoor air Room air Outdoor air


Dry bulb temperature 26ºC Dry bulb temperature 33ºC Dry bulb temperature 20ºC Dry bulb temperature 0ºC
Absolute humidity 10.5g/kg'(DA) Absolute humidity 20.1g/kg'(DA) Absolute humidity 7.3g/kg'(DA) Absolute humidity 1.9g/kg'(DA)
Air Air
conditioner Relative humidity 50% Relative humidity 63% conditioner
Relative humidity 50% Relative humidity 50%
Enthalpy 52.9kJ/kg(DA) Enthalpy 84.6kJ/kg(DA) Enthalpy 38.5kJ/kg(DA) Enthalpy 4.7kJ/kg(DA)

Energy-recovery calculating equation Energy-recovery calculating equation


Indoor supply-air = Outdoor – Outdoor
{ – Indoor
}
× Temp recovery
temperature (°C) temperature (°C) temperature (°C) temperature (°C) efficiency (%)
– –
Calculation example: 27.7°C=33°C (33°C 26°C)×76%
temperature (°C) {
Indoor supply-air = Indoor – Outdoor
temperature (°C) temperature (°C)

Calculation example: 16°C=(20°C 0°C)×80%+0°C
}
× Temp recovery + Outdoor
efficiency (%) temperature (°C)

*The above applies to the case of LGH-100RX5 (High fan speed).

Other Features
Lossnay provides better air ventilation because air is inducted and expelled concurrently, thereby offering more efficient operation than traditional
air ventilation (exhaust ventilation only).

If Lossnay
By inducting and expelling air
is used Supply air
If air is not supplied, the air pres- concurrently, Lossnay constant-
Exhaust air sure in the room drops and the Exhaust air ly provides sufficient ventilation
entire space is not properly ven- and maintains a good air envi-
tilated. ronment indoors.

142

P139-149.indd 142 13.12.12 1:26:29 PM


Mr. Slim & Lossnay Interconnected Ventilation Systems
High-quality Air Conditioning Systems Fusing Comfort and Economy

Mr. Slim Lossnay


Indoor Unit
Mr. Slim
Outdoor Unit
Mr. Slim A-control
Remote Controller

Six Major Merits of Interconnected Ventilation Systems


Problems

• Indoor-air is • Heating/Cooling • Conditioned air • Separate switches for • Air conditioner and • Maintenance such as
contaminated by airflow doesn’t reach expelled outside with air conditioner and ventilation fan opera- changing the filter is
odour, dust, etc. foot level exhaust air ventilation systems tion noise annoying difficult
• Air induction is • High running cost makes operation • Outside traffic noise
insufficient, resulting in troublesome annoying
insufficient ventilation. • Detailed zone-by-zone
operation not possible

Merits

Efficient, Comfortable Energy-saving Control with a single Quiet 1-year


fresh-air ventilation airflow ventilation remote controller operation no-maintenance filter

CO2 Sensor
The system allows you to measure CO2 density and thereby Fan speed Fan speed
control the amount of fresh air supplied. By connecting a CO2 High Extra-Low

sensor to the connector CN16, which is added to the LOSSNAY


main unit, the setting can be switched to High, Low, or Extra Low CO2

Low operation, which is selected when the sensor is turned High CO2 density

density CO2Sensor CO2Sensor


ON. This system produces additional energy conservation.

Air volume can be set using a pin position.


To force High fan CO2 sensor, etc. Remote display adaptor LOSSNAY
(When CO2 increases: Closed) (Optional) PAC-SA88HA-E control board
speed externally
Brown 1 When SW1 is “ON”, fan speed of the LOSSNAY will be set to
SW1 CN16
Red 2 “High” (Extra-High) regardless of the remote control setting. Use
Orange 3 this in such a way that it ventilates at Low or Extra-Low fan speed
Yellow 4
Fan speed/ normally, and when the external sensor detects contamination of
Green 5 Ventilation
mode selection indoor air, it changes to High (Extra High) fan speed operation.
SW1: High fan speed operation switch Not used. Insulate completely.
(When closed: For High fan speed operation) Max wiring length 10 m

One Remote Controller for All Operations


Control both Mr. Slim and Lossnay units with a single controller, the new “MA Remote Controller.” Compared
to conventional air conditioning and ventilation systems that require a separate remote controller for each unit,
operation is greatly simplified. A variety of features are incorporated, such as a “Ventilation Changeover Switch”
for independent operation of the Lossnay when running for long periods of time.

PAR-30MAA

Mr. Slim Air Conditioners Connectable with Lossnay Ventilation Units


Type Model Name Type Model Name
Ceiling Cassette (4-way) PLA-BA/SLZ-KA Ceiling PCA-KAQ/HAQ
PEAD-JA/PEA-GAQ Wall-mounted PKA-HA/KA
Ceiling-concealed
SEZ-KD Floor-standing PSA-GA
* The wired remote controller must be set before it can be used to operate individual Lossnay units.

143

P139-149.indd 143 13.12.12 1:26:29 PM


System Example Connection Method

A-control Slim-Lossnay connection cable


Mr. Slim outdoor unit (enclosed accessory)

Slim-Lossnay
0.5mm2 to 1mm2 sheathed
connection cable
PVC cable
(enclosed with Lossnay unit)

TM2
A-control
Lossnay Mr. Slim CN2L
Mr. Slim indoor unit
external indoor unit
control
Lossnay unit
input
LGH-RX5-E

500m
A-control No more than
remote controller

Lossnay Function Table (Interlocked settings)


Item Details
Number of indoor units that can be set to interlocked operation
1 unit
with 1 Lossnay unit in each group
Number of Lossnay units that can be set to interlocked operation
1 unit
with 1 indoor unit
Operation of Lossnay unit only Possible
(When indoor unit is stopped)

Independent Lossnay unit start and stop Not possible


(When indoor unit is operating)
30 minute delayed operation when indoor unit cooling/ heating
Delayed operation (Optional setting)
is started
Fan speed switching High/ Low*
Ventilation mode Automatic
Filter indicator None
Error indicator None
The Lossnay remote controller cannot be used for systems
Restrictions and precautions interlocked with Mr. Slim.

* Cannot select extra-low fan speed when using the MA Remote Controller.

Controller Function Table for Lossnay Units Switched and display : Group only (or function available) : Not available

Local remote
Model MA Remote Controller Lossnay Remote Controller
PAR-21MAA PAR-30MAA PZ-60DR-E
Start /Stop
Operation

Fan speed switching (High/Low)*


Ventilation mode switching (Automatic) (Automatic)
Priority instructions
Local permitted/prohibited
Status (Operation/Stop) Cannot be used
Fan speed switching (High/Low) with interlocked
Lossnays
Monitoring

Ventilation mode
Error indicator
Error content
Filter sign
Local permitted/prohibited
* Cannot select extra-low fan speed when using the MA Remote Controller.

144

P139-149.indd 144 13.12.12 1:26:29 PM


Specifications / Dimensions
LGH-15RX5-E
Model LGH-15RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 0.44-0.46 0.37-0.38 0.25-0.25 0.14-0.15 0.45-0.46 0.37-0.38 0.25-0.26 0.14-0.15
Power Consumption (W) 96-110 80-90 53-59 30-35 97-110 81-91 54-61 30-35
(m3/h) 150 150 110 70 150 150 110 70
Air Volume
(L/s) 42 42 31 19 42 42 31 19
(mmH2O) 10.2-10.7 6.6-7.1 3.6-4.1 1.4 10.2-10.7 6.6-7.1 3.6-4.1 1.4
External Static Pressure
(Pa) 100-105 65-70 35-40 14 100-105 65-70 35-40 14
Temperature Exchange Efficiency (%) 82.0 82.0 84.0 85.5
Heating 75.0 75.0 77.5 81.0
Enthalpy Exchange Efficiency (%)
Cooling 73.0 73.0 76.5 81.0
(measured at 1.5m under the center
SPL (dB) 27.5-28 26.5-27 22-23.5 18 28.5-29 27-28 23-24 18-19
of apanel in an anechoic chamber)
Weight (kg) 20
Starting Current 0.8A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 10dB higher than the indicated value at high fan speed.

50Hz/Single-phase, 220V 50Hz/Single-phase, 240V Position where duct direction change is possible
90 Exchange 90 Exchange
efficiency Tempe efficiency Tempe Bypass damper plate
(%) Entha efficie rature exch Entha efficie rature exch
lpy ex ncy ange (%) lpy ex ncy ange 102 Ceiling suspension fixture
80 Enth chan 80 Enth chan 768
alp ge e
ffic alp
ye
ge e
ffic (4-13x20 oval)
ye ienc 100mm xch ienc 100mm Air exhaust fan 65
xch y(H dia y(H dia
ang eati ang eati
e e ng) pipe e ng) pipe
70 300 ff 70 300 eff
30 icie length 30 icie length EA RA
nc nc (return air)
y(C y(C (exhaust-air outlet)
oo oo
ling 20m ling 20m
60 25 250 ) 60 25 250 )

735
530

782
50 20 200 Extra high 50 20 200 Extra high
15m 15m
SA

95
OA (supply air)
(outside-air intake)
External static pressure

External static pressure

15 150 15 150 Power supply

More than 600


Low 10m cable opening

20
Low 10m
102

150 ~250
Core, air filter, high- 65
Pa

Pa
mmH 2 O

mmH 2 O

10 100 10 100 High Air supply fan 30


Extra low
High efficiency filter, fan, Inspection
Extra low
5m 5m maintenance space opening Control box 273
5 50 5 50
Maintenance cover
High-efficiency filter (sold separately)
0 0 LOSSNAY core attachment position
0 50 100 150 200 250 0 50 100 150 200 250
(m /h)
3
(m /h)
3 103 780 103

97.5
110
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70

30
Air volume (L/s) Air volume (L/s)

Position where duct direction


change is possible Air filters (EU-G3)
Unit: mm

LGH-25RX5-E
Model LGH-25RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 0.52-0.55 0.47-0.48 0.26-0.27 0.17-0.18 0.53-0.55 0.47-0.48 0.26-0.27 0.17-0.18
Power Consumption (W) 113-129 102-114 56-62 36-42 115-131 103-115 56-63 36-42
(m3/h) 250 250 155 105 250 250 155 105
Air Volume
(L/s) 69 69 43 29 69 69 43 29
(mmH2O) 8.2-8.7 5.1-6.1 2-2.5 0.9 8.2-8.7 5.1-6.1 2-2.5 0.9
External Static Pressure
(Pa) 80-85 50-60 20-25 9 80-85 50-60 20-25 9
Temperature Exchange Efficiency (%) 79.0 79.0 81.5 83.5
Heating 69.5 69.5 74.0 77.5
Enthalpy Exchange Efficiency (%)
Cooling 68.0 68.0 72.5 76.0
(measured at 1.5m under the center
SPL (dB) 26-27 25-26 20-21.5 18-19 26.5-27.5 25.5-26.5 20.5-22 18-19
of apanel in an anechoeic chamber)
Weight (kg) 20
Starting Current 0.9A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 10dB higher than the indicated value at high fan speed.
50Hz/Single-phase, 220V Position where duct direction change is possible
90 Exchange 50Hz/Single-phase, 240V
Tem 90 Exchange Bypass damper plate
efficiency
effic perature efficiency Tem
Enth ienc
y exchang efficperature Ceiling suspension fixture
80 ienc 102
alpy
exch e 80 Enth
alpy y exchang 768
Enth ang exch e (4-13x20 oval)
alp ee
fficie Enth ang Air exhaust fan 65
y ex alpy e eff
70 cha ncy icien
nge (He 70 exc cy(H
atin han eati RA
effic g) ge ng) EA
ienc effic (return air)
y(Co ienc (exhaust-air outlet)
60 oling y(Co
) 60 oling
)
735
530

782

50 25 250 150
Extra high 50 25 250 150
dia Extra high
pipe dia SA
95

20 200 pipe OA
length
20 200 length (supply air)
(outside-air intake) Power supply
External static pressure

40m
External static pressure

40m
More than 600

cable opening
20

15 150
15 150 102
30m 65
150 ~250

Low Core, air filter, high-


mmH 2 O

Low 30m Air supply fan


High 30
mmH 2 O

10 100 High efficiency filter, fan, Inspection


Pa

Extra low 20m 10 100 maintenance space


Pa

Extra low 20m opening Control box 273


5 50 10m
Maintenance cover
5 50 10m
High-efficiency filter (sold separately)
LOSSNAY core attachment position
0 0 50 100 150 200 250 300 350 400
0 0 50 100 150 200 250 300 350 400
63 780 63
(m3/h)
(m3/h)
160
142
30

0 10 20 30 40 50 60 70 80 90 100
0 10 20 30 40 50 60 70 80 90 100
Air volume (L/s)
Air volume (L/s)

Position where duct direction


change is possible Air filters (EU-G3)
Unit: mm

145

P139-149.indd 145 13.12.12 1:26:30 PM


LGH-35RX5-E
Model LGH-35RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 0.92-0.92 0.74-0.74 0.5-0.51 0.28-0.3 0.93-0.94 0.77-0.77 0.51-0.52 0.28-0.3
Power Consumption (W) 195-212 160-169 105-116 58-69 197-217 164-173 105-116 58-69
(m3/h) 350 350 210 115 350 350 210 115
Air volume
(L/s) 97 97 58 32 97 97 58 32
(mmH2O) 15.8-16.3 7.6-8.2 2.5-3.1 0.9 15.8-16.3 7.6-8.2 2.5-3.1 0.9
External Static Pressure
(Pa) 155-160 75-80 25-30 9 155-160 75-80 25-30 9
Temperature Exchange Efficiency (%) 80.0 80.0 85.0 88.0
Heating 71.5 71.5 76.5 81.5
Enthalpy Exchange Efficiency (%)
Cooling 71.0 71.0 75.5 81.0
(measured at 1.5m under the center
SPL (dB) 32-32 28.5-29.5 21.5-23 18 32.5-32.5 29.5-30.5 21.5-24 18
of apanel in an anechoic chamber)
Weight (kg) 29
Starting Current 2.4A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 10dB higher than the indicated value at high fan speed.

50Hz/Single-phase, 220V 50Hz/Single-phase, 240V Position where duct direction change is possible
90 90
Exchange Tempe Exchange Tempe Air exhaust fan 124 Bypass damper plate
efficiency Enth effic rature ex efficiency Enth effic rature ex
ienc Ceiling suspension fixture
alpy ienc chan alpy y chan 875
80 (%) exch
y ge (%) exch ge 80
ang
80 (4-13x20 oval)
Enth e eff Enth ang
alpy alpy e eff
exch icien exch icien
ang cy(H ang cy(H EA RA
70 350 e eff eatin e eff eatin
icien g) 70 350 icien g) (exhaust-air outlet) (return air)
cy(C cy(C
oolin oolin
g) g)

921
60 300

874
650
30 150mm 60 30 300 150mm
dia dia
Extra high pipe Extra high pipe
50 250 length 50 250 length
25 25 SA

95
OA (supply air)
30m 30m (outside-air intake)
200 200 Power supply
20 20

More than 600


cable opening

20
External static pressure

80
External static pressure

High High

150~250
15 150 15 150 Extra low Core, air filter, high- 124 Air supply fan 55
20m 20m Inspection
efficiency filter, fan, 315
maintenance space opening Control box
Low Low
mmH 2 O

mmH 2 O

10 100 Extra 10 100


low Maintenance cover
Pa

Pa

10m 10m
High-efficiency filter (sold separately)
5 50 5 50 LOSSNAY core attachment position
64 888 64

160
142
0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500
(m3/h) (m3/h)

0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140


Air volume (L/s) Air volume (L/s) 55
Position where duct direction Air filters (EU-G3)
change is possible
Unit: mm

LGH-50RX5-E
Model LGH-50RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 1.2-1.25 1.0-1.0 0.85-0.85 0.4-0.4 1.25-1.25 1.0-1.0 0.85-0.85 0.4-0.4
Power Consumption (W) 255-286 207-228 175-190 80-95 260-290 210-230 180-195 80-95
(m3/h) 500 500 390 180 500 500 390 180
Air Volume
(L/s) 139 139 108 50 139 139 108 50
(mmH2O) 15.3-15.8 6.6-9.2 4.1-6.1 1.0 15.3-15.8 6.6-9.2 4.1-6.1 1.0
External Static Pressure
(Pa) 150-155 65-90 40-60 10 150-155 65-90 40-60 10
Temperature Exchange Efficiency (%) 78.0 78.0 81.0 86.0
Heating 69.0 69.0 71.0 78.0
Enthalpy exchange efficiency (%)
Cooling 66.5 66.5 68.0 77.0
(measured at 1.5m under the center
SPL (dB) 33-34 30.5-32 26.5-28 19 34-35 31-32.5 27-29 19
of apanel in an anechoic chamber)
Weight (kg) 32
Starting Current 3.0A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 16dB higher than the indicated value at high fan speed.
50Hz/Single-phase, 220V Position where duct direction change is possible
90 50Hz/Single-phase, 240V Bypass damper plate
Exchange Tempe 90 Air exhaust fan 124
efficiency rature Exchange Tempe Ceiling suspension fixture
Enth
exch
ange efficiency rature
exch
875
(%) 400 alp efficie Enth ange 65
80 y ex ncy 80
(%) 400 alp efficie
chan y ex ncy
ge ef chan
Entha ficienc ge effic RA
lpy y (H Entha iency EA
70 35 350 exch eatin
g) 70 350 lpy (Hea (exhaust-air outlet) (return air)
ange 35 exch ting)
efficie ange
ncy efficie
(Coo ncy
ling) (Coo
1016

1063

60 300
745

30 Extra high 60 300 ling)


30 Extra high
200mm
dia 200mm
50 25 250 pipe dia
50 25 250 pipe
length
length OA SA
200 (supply air)
95

20 60m 200 (outside-air intake)


External static pressure

20 60m Power supply


External static pressure

More than 600

High 50m cable opening


20

15 150 50m
15 150 124 65
150~250

40m Core, air filter, high- Air supply fan 30


mmH 2 O

40m
Pa

Low
mmH 2 O

High efficiency filter, fan, Inspection


Pa

Low
10 100 30m maintenance space opening Control box 315
10 100 30m
Extra low Maintenance cover
20m Extra low
20m
5 50
10m 5 50 High-efficiency filter (sold separately)
10m LOSSNAY core attachment position
79 888 79
0 0 100 200 300 400 500 600 700
0 0 100 200 300 400 500 600 700
208
192

(m /h)
3
(m3/h)

0 20 40 60 80 100 120 140 160 180 200


0 20 40 60 80 100 120 140 160 180 200
30

Air volume (L/s)


Air volume (L/s)
Position where duct direction Air filters(EU-G3)
change is possible
Unit: mm

146

P139-149.indd 146 13.12.12 1:26:30 PM


LGH-65RX5-E
Model LGH-65RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 1.7-1.8 1.5-1.5 1.2-1.2 0.6-0.6 1.7-1.8 1.5-1.5 1.2-1.2 0.6-0.6
Power Consumption (W) 350-380 308-322 248-265 120-140 350-385 310-335 250-265 120-140
(m3/h) 650 650 520 265 650 650 520 265
Air Volume
(L/s) 181 181 144 74 181 181 144 74
(mmH2O) 11.2-12.2 6.1-8.2 4.1-5.1 0.8 11.2-12.2 6.1-8.2 4.1-5.1 0.8
External Static Pressure
(Pa) 110-120 60-80 40-50 8 110-120 60-80 40-50 8
Temperature Exchange Efficiency (%) 77.0 77.0 80.0 86.0
Heating 68.5 68.5 70.5 78.0
Enthalpy exchange efficiency (%)
Cooling 66.0 66.0 68.5 77.0
(measured at 1.5m under the center
SPL (dB) 34-34.5 32-33 28.5-31.5 22 34.5-35 32.5-33.5 28.5-30.5 22-22.5
of apanel in an anechoic chamber)
Weight (kg) 40
Starting Current 4.4A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 10dB higher than the indicated value at high fan speed.

50Hz/Single-phase, 220V 50Hz/Single-phase, 240V Position where duct direction change is possible
90 Exchange 90 Exchange
efficiency Tempe efficiency Tempe 133 Bypass damper plate
(%) rature rature
80
exchan
geefficie (%) exchan Air exhaust fan 895 Ceiling suspension fixture
Enthal nc 80 Enthal ge efficie
py exch y py exch ncy (4-13x20 oval) 70
Enth an geefficie Enth angeeff
alpy ncy (H alpy iciency
70 45 450 exchan eating) 70 450 exchan (Heatin RA
geefficie 45 geefficie g) EA
ncy (C
ooling) ncy (C (exhaust-air outlet) (return air)
ooling)
60 40 400 200mm 60 400 200mm
40
dia

1001
dia

954
692
pipe pipe
50 35 350 length 50 350 length
35
Extra high Extra high
60m
30 300 30 300 SA
OA (supply air)
50m 50m

95
25 250 250 (outside-air intake)
25
External static pressure

External static pressure

Power supply

More than 600

20
200 Low 40m Low 40m cable opening
20 20 200 133

150~250
Core, air filter, high-
High Inspection Air supply fan 70
30m efficiency filter, fan,
mmH2O

30m
mmH2O

15 150 15 150 High opening Control box 386


maintenance space
Pa

Pa

Extra low 20m Extra low Maintenance cover


10 100 10 100 20m
High-efficiency filter (sold separately)
5 50 10m 5 50 10m LOSSNAY core attachment position
79 908 79

208
192
0 0
0 100 200 300 400 500 600 700 800 900 0 100 200 300 400 500 600 700 800 900
(m3/h) (m3/h)

0 25 50 75 100 125 150 175 200 225 250 0 25 50 75 100 125 150 175 200 225 250
Air volume (L/s) Air volume (L/s)
Position where duct direction Air filters (EU-G3)
change is possible
Unit: mm

LGH-80RX5-E
Model LGH-80RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65
Power Consumption (W) 380-415 345-370 315-340 125-145 380-415 345-370 315-340 120-145
(m3/h) 800 800 700 355 800 800 700 355
Air Volume
(L/s) 222 222 194 99 222 222 194 99
(mmH2O) 14.8-15.3 10.7-12.2 8.2-9.7 2 14.8-15.3 10.7-12.2 8.2-9.7 2
External Static Pressure
(Pa) 145-150 105-120 80-95 20 145-150 105-120 80-95 20
Temperature Exchange Efficiency (%) 79.0 79.0 80.5 87.5
Heating 71.0 71.0 72.5 79.5
Enthalpy exchange efficiency (%)
Cooling 70.0 70.0 71.5 79.5
(measured at 1.5m under the center
SPL (dB) 33.5-34.5 32-33 30-31 22 34.5-35.5 33-34 31-32 22
of apanel in an anechoic chamber)
Weight (kg) 53
Starting Current 3.8A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 16dB higher than the indicated value at high fan speed.

Exchange 50Hz/Single-phase, 220V Position where duct direction change is possible


90 Exchange 50Hz/Single-phase, 240V 165
efficiency 90 Bypass damper plate
(%) Tem efficiency Tem 1010
effic peratu (%) Air exhaust fan Ceiling suspension fixture
En ienc re e effic peratu (4-15x20 oval)
tha y xch En ienc re e
80 lpy ange tha y xch
80 lpy ange
exch
ange exch RA
Enth effic ange EA
effic alpy e ienc Enth effic (exhaust-air outlet) (return air)
y ienc
70 500 ienc xcha
y(C nge
(H eati
ng) effic alpy exc y(H
50 oolin 70 500 ienc hang eati
50 ng)
1004

1036

y(C
oolin e
690

g)
g)
60 400 Extra high
40 60 400 Extra high
40
250mm SA
250mm OA (supply air)
95

dia (outside-air intake)


pipe dia
50 30 300
length 50 pipe Power supply
30 300
More than 600

length cable opening


High
Core, air filter, high- 165
150~250

Low 100m High 389


Air supply fan
External static pressure

Low 100m efficiency filter, fan,


External static pressure

20 200 Inspection 399


80m 20 200 maintenance space opening Control box
80m
Extra low Maintenance cover
mmH 2 O

60m
mmH 2 O

Extra low 60m


Pa

10 100
Pa

40m 10 100 40m


High-efficiency filter (sold separately)
20m LOSSNAY core attachment position
20m
79 1144 79
258
242

0 0 200 400 600 800 1000 1200


0 0 200 400 600 800 1000 1200
(m3/h)
(m3/h)
0 50 100 150 200 250 300 350
0 50 100 150 200 250 300 350
Air volume (L/s)
Air volume (L/s)
Position where duct direction Air filters(EU-G3)
change is possible
Unit: mm

147

P139-149.indd 147 13.12.12 1:26:30 PM


LGH-100RX5-E
Model LGH-100RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi High Lo Extra-Lo Extra-Hi Hi Lo Extra-Lo
Operating Current (A) 2.3-2.4 2.1-2.1 1.7-1.7 0.9-0.9 2.3-2.4 2.1-2.1 1.7-1.7 0.9-0.9
Power Consumption (W) 500-535 445-475 350-380 175-200 510-550 460-485 365-395 175-200
(m3/h) 1000 1000 755 415 1000 1000 755 415
Air Volume
(L/s) 278 278 210 115 278 278 210 115
(mmH2O) 16.3-17.3 10.2-11.2 5.6-6.1 1.8 16.3-17.3 10.2-11.2 5.6-6.1 1.8
External Static Pressure
(Pa) 160-170 100-110 55-60 18 160-170 100-110 55-60 18
Temperature Exchange Efficiency (%) 80.0 80.0 83.0 87.0
Heating 72.5 72.5 74.0 80.0
Enthalpy exchange efficiency (%)
Cooling 71.0 71.0 73.0 79.0
(measured at 1.5m under the center
SPL (dB) 36-37 34-35 31-32.5 21-22 37-38 35-36 32-33 21-22
of apanel in an anechoic chamber)
Weight (kg) 59
Starting Current 4.6A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 17dB higher than the indicated value at high fan speed.
50Hz/Single-phase, 220V 50Hz/Single-phase, 240V Position where duct direction change is possible
90 90 Exchange 165 Bypass damper plate
Exchange Tem Tem
efficiency effic perature
efficiency effic perature Air exhaust fan 1010 Ceiling suspension fixture
(%) Enth ienc (%) Enth ienc exc (4-15x20 oval)
alpy y exc alpy y han
han exc ge
exc ge 80 En han
80 En han tha ge
tha ge lpy efficie EA RA
lpy efficie exc ncy(
exc ncy( han Heatin (exhaust-air outlet) (return air)
han Heatin ge g)
ge g) effic
70 500 effic 70 50 500 ienc
50 ienc y(C
y(C

1231

1263
oolin oolin

917
g) g)
250mm 250mm
60 400 60 40 400 dia
40 dia Extra high
Extra high pipe
pipe
length length OA SA
(supply air)

95
100m 100m (outside-air intake)
50 300 50 30 300
30 Power supply

More than 600


80m 80m cable opening
External static pressure

Core, air filter, high- 165

150~250
External static pressure

20 200 20 200 High 60m efficiency filter, fan, Air supply fan
60m Inspection 399
High Low maintenance space opening Control box
Low
m mH 2 O
mmH 2 O

40m 40m Maintenance cover


Pa

Extra low
Pa

Extra low 10 100


10 100 High-efficiency filter (sold separately)
20m LOSSNAY core attachment position
20m
79 1144 79

258
242
0 0 200 400 600 800 1000 1200 1400 0 0 200 400 600 800 1000 1200 1400
(m3/h) (m3/h)

0 50 100 150 200 250 300 350 400 0 50 100 150 200 250 300 350 400
Air volume (L/s) Air volume (L/s) Position where duct direction Air filters (EU-G3)
change is possible
Unit: mm

LGH-150RX5-E
Model LGH-150RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Hi Hi Lo
Operating Current (A) 3.5-3.5 3.2-3.2 2.9-2.9 3.5-3.5 3.2-3.2 2.9-2.9
Power Consumption (W) 760-830 690-740 630-680 765-835 695-745 635-685
(m3/h) 1500 1500 1300 1500 1500 1300
Air Volume
(L/s) 417 417 361 417 417 361
(mmH2O) 16.3-17.8 13.3-13.8 9.7-10.2 16.3-17.8 13.3-13.8 9.7-10.2
External Static Pressure
(Pa) 160-175 130-135 95-100 160-175 130-135 95-100
Temperature Exchange Efficiency (%) 80.0 80.0 81.0
Heating 72.0 72.0 72.5
Enthalpy exchange efficiency (%)
Cooling 70.5 70.5 71.5
(measured at 1.5m under the center
SPL (dB) 38-39 36-37.5 33.5-35 39-40.5 37.5-39 35.5-37
of apanel in an anechoic chamber)
Weight (kg) 105
Starting Current 7.3A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 19dB higher than the indicated value at high fan speed.
50Hz/Single-phase, 220V 50Hz/Single-phase, 240V Bypass damper plate
90 Exchange 90 Exchange
efficiency Tempe efficiency Tempe Ceiling suspension fixture
(%) effic rature ex Air exhaust fan 1010
ienc chan
(%) effic rature ex (4-15x30 oval)
y ge ienc chan
y ge
80 Enth 80 Enth
alpy
270

exc alpy RA
Enth han exc (return air)
alpy ge e Enth han EA
fficie alpy ge e
exch fficie (exhaust-air outlet)
1004

1045

ncy exch
690

690

70 500 ang (He ang ncy


50 e eff 70 50 500 e eff (He
icie atin icie atin
ncy g) ncy g)
(Co (Co OA
olin olin SA
110
270

g) g) (outside-air intake)
60 40 400 60 400 (supply air)
40
Extra high Extra high
More than 600

27

399
150~250

50 300 Core, air filter, high- Inspection 798


30 50 30 300 Air supply fan
efficiency filter, fan, opening
External static pressure

External static pressure

maintenance space Control box Power supply


cable opening
(mmH 2 O)

(mmH 2 O)

20 200 20 200 Maintenance cover


Low Low

High-efficiency filter (sold separately)


(Pa)

(Pa)

10 100 High
10 100 LOSSNAY core attachment position
High
44 1144 79
258
242

0 0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
(m3/h) (m3/h)
700

0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700
Air volume (L/s) Air volume (L/s)
258
242

Air filters (EU-G3)


Unit: mm

148

P139-149.indd 148 13.12.12 1:26:30 PM


LGH-200RX5-E
Model LGH-200RX5-E
Power Supply (V/Phase/Hz) 220-240 / Single / 50
Ventilation Mode LOSSNAY ventilation Bypass ventilation
Fan Speed Extra-Hi Hi Lo Extra-Hi Hi Lo
Operating Current (A) 4.8-4.8 4.2-4.2 3.4-3.4 4.8-4.8 4.2-4.2 3.4-3.4
Power Consumption (W) 1035-1100 910-980 715-785 1040-1110 915-980 720-785
(m3/h) 2000 2000 1580 2000 2000 1580
Air Volume
(L/s) 556 556 439 556 556 439
(mmH2O) 16.3-16.8 10.2-10.7 6.1-6.6 16.3-16.8 10.2-10.7 6.1-6.6
External Static Pressure
(Pa) 160-165 100-105 60-65 160-165 100-105 60-65
Temperature Exchange Efficiency (%) 80.0 80.0 83.0
Heating 72.5 72.5 73.5
Enthalpy exchange efficiency (%)
Cooling 71.0 71.0 72.0
(measured at 1.5m under the center
SPL (dB) 39.5-40 37-38 32.5-34 40.5-41 38-39 33.5-35
of apanel in an anechoic chamber)
Weight (kg) 118
Starting Current 11.9A
*The air outlet noise (45o angle,1.5 meters in front of the unit) is about 20dB higher than the indicated value at high fan speed.
50Hz/Single-phase, 220V 50Hz/Single-phase, 240V Bypass damper plate
90 Exchange 90 Exchange
efficiency Tem efficiency Tem Ceiling suspension fixture
perat perat Air exhaust fan 1010
(%) ure ex (%) ure ex
chan chan (4-15x30 oval)
Entha ge e ge e
80 fficie 80 Entha fficie
lpy ex

270
ncy lpy ex ncy RA
chan chan
ge ef ge ef EA (return air)
Enth ficie ncy(H Enth ficie
alpy eating) ncy(H (exhaust-air outlet)
exch alpy eating)
exch

1231

1272
70 500 ange 70 500 ange

917

917
50 efficie efficie
ncy(C 50 ncy(C
ooling) ooling)

60 400 60 400 OA

110
270
40 40 (outside-air intake) SA
Extra high Extra high (supply air)

More than 600

27
50 300 50 300 399

150~250
30 30 Core, air filter, high-
External static pressure

Inspection
External static pressure

Air supply fan 798


efficiency filter, fan, opening
maintenance space
(mmH 2 O)

Control box
(mmH 2 O)

200 High 200 High Power supply


20 20 cable opening
Low Low Maintenance cover
High-efficiency filter (sold separately)
(Pa)

(Pa)

10 100 10 100 LOSSNAY core attachment position


44 1144 79

258
242
0 0
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
(m3/h) (m /h)
3 700
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700
Air volume (L/s) Air volume (L/s)

258
242
Air filters (EU-G3)
Unit: mm

LGH-40ES-E
Supply Temperature Enthalpy Recovery
Power Supply Air Volume
Power Consumption Recovery Efficiency (%) Noise Weight
Voltage Frequency Fan Speed
(W) Efficiency (%) (dB(A)) (kg)
(V) (Hz) (m3/h) (L/s) Heating Cooling

1-phase Hi 132-146 400 111 60 45 40 41-43


50 25
220~240 Lo 82-95 250 69 66 54 48 32-34
*The value of noise was measured at an anechoic chamber. it may vary depending on the room structure, building materials or the way the main was installed.

Exchange
efficiency
(%) 50Hz
80
Tem
per
255

atu
re r SA
127.5

70 En eco
tha ver (Supply
lpy ye air )
ffici 15 30
rec e ncy RA (Return air)
ove
60 ry
En eff Ceiling suspension
tha icie fixture (4 pcs.)
lpy ncy
rec (He
50 ov atin Control Switch (PZ-03SLP-E)
ery g)
693
495

eff 12.2 20.4


290

icie
nc 116 6.5
40 300 y(
Co
olin
g)
98
External static pressure

200 High
120

117
68

Power supply terminal OA EA


(Pa)

(Outside-air (Exhaust- Power Terminal


100 Low block intake) air outlet) board
* Power supply cord lamp
600
opening at the top
845 Fan speed Power switch Switch box
0 100 200 300 400 500 900 selector switch
Air volume (m3/h)
*Power supply cord opening Unit: mm

149

P139-149.indd 149 13.12.12 1:26:30 PM


VL-100EU5-E
Supply Power line Power Temp.exchange
Fan Air volume Noise Weight
voltage frequency consumption efficiency
speed (m3/h) (dB) (kg)
(V) (Hz) (W) (%)
HI 100 30 73 36.5
220 50
LO 55 13 80 24
HI 105 31 73 37
230 50
LO 60 15 80 25 7.5
HI 106 34 72 38
240 50
LO 61 17 79 27
HI 103 34 73 38
220 60
LO 57 17 80 25

(ADJUSTABLE)
MOUNTING PLATE REQUIRE TO BE SECURED
REQUIRE TO BE SECURED

13.5
EDGE OF MAIN UNIT 420

40

from nearest
obstruction
PITCH 20X10=200

183min
119
95.5

238.5
25

265
15
87
97

95
108
MOUNTING HOLES

233min
36×ø6

(ADJUST (ADJUST

25
75 ABLE) 200(MIN) 75 ABLE)
350(MAX)
POWER CORD HOLE
267.5 292
AIR EXHAUST HOLE 530 AIR INTAKE HOLE
ø85 to ø90 WALL HOLE 554 ø85 to ø90 WALL HOLE
620
360min from nearest obstruction 360min

FRONT PANEL
(OPEN POSITION)

12
INDOOR AIR EXHAUST

OUTER DIA
A
OUTER DI
FRONT PANEL

ø79×2
ø75×2
(CLOSED POSITION)

FRONT PANEL LOUVER


(VERTICAL POSITION)

ø150

FRONT PANEL LOUVER
(HORIZONTAL POSITION)

90 140 22 17
FRESH AIR SUPPLY
54 WALL THICKNESS
620 226 200 50 to 550 106

SHUTTER KNOB SHUTTER KNOB

Doing Our Part to


(CLOSED POSITION) (OPEN POSITION) Unit: mm

VL-100U5-E
Supply Power line Power Temp.exchange

Create a Better Future for All...


Fan Air volume Noise Weight
voltage frequency consumption efficiency
speed (m3/h) (dB) (kg)
(V) (Hz) (W) (%)
HI 100 30 73 36.5
220 50
LO 55 13 80 24
HI 105 31 73 37
230 50
LO 60 15 80 25 7.5
Core Environmental Policy 240 50
HI 106 34 72 38
LO 61 17 79 27
HI 103 34 73 38
220 60
The Mitsubishi Electric Group promotes sustainable development and is LO 57 17 80 25

committed to protecting and restoring the global environment through technology,

(ADJUSTABLE)
MOUNTING PLATE REQUIRE TO BE SECURED
REQUIRE TO BE SECURED
through all its business activities, and through the actions of its employees.

13.5
EDGE OF MAIN UNIT 420

40

from nearest
obstruction
PITCH 20X10=200

183min
119
95.5

238.5
25

265
Environmental Vision 2021

15
87

95
108
MOUNTING HOLES

233min
36×ø6

(ADJUST (ADJUST
75 ABLE) 200(MIN) 75 ABLE)
350(MAX)
267.5 292
AIR EXHAUST HOLE 530 AIR INTAKE HOLE
ø85 to ø90 WALL HOLE 554 ø85 to ø90 WALL HOLE
620
360min from nearest obstruction 360min

Making Positive Contributions to the Earth FRONT PANEL


(OPEN POSITION)
and its People through Technology and Action

12
INDOOR AIR EXHAUST

OUTER DIA
A
OUTER DI
FRONT PANEL

ø79×2
ø75×2
(CLOSED POSITION)

FRONT PANEL LOUVER


(VERTICAL POSITION)

ø150

Preventing Global Warming Creating a Recycling-Based Society FRONT PANEL LOUVER
(HORIZONTAL POSITION)

●Reduce CO 2 emissions from product usage by 30% ●Reduce, reuse and recycle “3Rs” products 90 140 17
FRESH AIR SUPPLY 22
●Reduce total CO 2 emissions from production by 30% reduce resources used by 30% 252 175 54 WALL THICKNESS
●Aim to reduce CO 2 emissions from ●Zero emissions from manufacturing reducing 620 226 200 50 to 550 106

power generation the direct landfill of waste to zero SHUTTER KNOB SHUTTER KNOB
(CLOSED POSITION) (OPEN POSITION) Unit: mm

Ensuring Harmony with Nature Fostering Environmental Awareness

1 150
SPLIT-TYPE
YPE AIR COND
CONDITIONERS
DITION Full Product Line Catalogue 2014
14
NOTICE
■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the
refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Eco Changes is the Mitsubishi Electric Group’s environmental statement,


Wrap Yourself in Comfort and Quiet
and expresses the Group’s stance on environmental management. Eco-conscious Technologies from Japan
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.

Full Product Line Catalogue

2014
Revised publication effective Jan. 2014.
Superseding publication of S-179-3-C9236-B Jul. 2013.
S-179-3-C9236-B SI1401 Printed in Japan (MDOC) Specifications are subject to change without notice.

cover_F.indd 1 13.12.12 1:14:49 PM