TABLE OF CONTENT
DESCRIPTION
RTU50 HARDWARE OVERVIEW
¢ RTU C50 MASTER PROCESSOR MODULE,
RTU C50 POWER SUPPLY MODULES
¢ RTUCS0 DUAL COMMUNICATION MODULE
© RTU C50 OPTONET MODULE
© RTU C50 INPUT/OUTPUT MODULE
RTUS50 SOFTWARE OVERVIEW
¢ RTU C30 CONFIGURATION USER MANUAL
© RTU C50 FIRMWARE WISP+ PROTOCOL USER DOCUMENT
© RTU C50 IEC 60870-5-101 SLAVE USER MANUAL
SECTIONSECTION A-1
RTU C50 MASTER PROCESSOR
MODULEFOXBORO
a
PSS 21H-8C1 B4
VA Series® Remote Terminal Unit (RTU)
RTU 50 Pll and PIIE Master Processor Modules
‘The RTU 50 Pll and PIIE Master Processor Modules
are the heart of the ATU 50, delivering features such
as user-dofined calculations and database; system
‘maintenance and diagnostics; real-time operating
system for deterministic monitoring and control;
industry standard processor. The PIE Master
Processor Module also features a 10BaseFL duat
Ethemet intoriace for local (LAN) and wide (WAN)
area network applications,
‘The RTU 50 Pll and PIIE use standard Industry
architecture, incorporating a 92-bit processor and
FLASH technology to deliver powerful and flexible
inteligencs to the RTU 50
"An Invensys company
FEATURES:
Key features are:
‘AMD 22-bit microprocessor
Altera programmable chipset
4.MB FLASH
16 MB RAM
Diagnostic LEDs
128 K Protecied Mode BIOS.
Foxboro Electrobus interface
IEEE P996 bus interface
‘1 ms time base ‘or Sequence of Events (SOE)
time tagging
Watchdog timer
‘Two RS-282-C serial ports
Real-time calendar clock - 5 ppm
Non-volatile parameter memory.
Product SpecificationsPSS 21H-8C1 BA
Page 2
Optional Features
‘Avaliable optional features are:
+ 64 MHz, AMAB6DX¢, 32-bit microprocessor
+ Upto 128 MB RAM (EDO SIMM)
+ Upto 10MB FLASH
+ Dual 10BaseFL Ethernet Interface,
‘OVERVIEW
‘The RTU 50 Pll end PIIE modules utlize standard PC
aichitecture to deliver powerful and scalable
processing capability to the ATU 50. Foaturing a
82-bit processor and FLASH memory, the ATU 50 Pll
and PIIE Masior Processor Modules control all RTU
logic and diagnostics, and provides support for
optional periphorals and 10BaseFL Ethemet
‘communication interface.
‘The module features dlagnostic LEDS for rapid feut
diagnosis and an intogral serial port for connection of
dlagnostio and configuration tools. A second serial
portis also available for interfacing to inteligent
electronic devices. This port is user programmable,
allowing the implementation of proprietary and
industry standard protocols (such as Modbus).
‘The RTU 50 Pll and PIIE reside alongside the power
‘supply inthe first slot of the RTU 80 main fl.
FUNCTIONAL DESCRIPTION
‘The ATU 50 Pll and PIIE provide PC 1/0 servioss,
memory Integrity checks, and interrupt checks to
guarantee the reliable and deterministic operation of
all RTU processes and logic. The powerful standard
processor comes complete with 16 MB of RAM,
16 KB of cache memory, maths co-processor, 128 KB
of EPROM and 2 MB of FLASH
FLASH
A key feature of tho RTU 50 Pil and PIIE is the use of
FLASH for the storage of the AMX® Real-Time
Operating systam, ATU system software, ATU
database configurations and user configurable
calculations. The system is flexible, allowing the user
to pre-program the necessary software and database
requirements within an office environment or on site.
‘The new FLASH card is then simply installed into a
pre-commissioned ATU. This ‘exibility permits easy
Upgrades of ATU sofiware aid Ualabasy changus.
‘The software package also provides diagnostic
functions for system maintenance, which operates in
conjunction with a personal computer to provide
aceass to /O logic, communications and controls.
DUAL 10BASEFL ETHERNET BOARD
‘The ATU 50 PIIE features a dual 10BaseFL Ethemet
board that provides a cost-effective and versatile fiber
optic Ethernet interface for the UA Serios RTU 50.
‘The optical interface maintains the high electrical
Isolation characteristics of the RTU 60.
‘The dual communications channels function as
primary and backup paths, delivering fault-tolerant
‘communications for critical processes.
‘The rapid deployment of the Ethernet as a network
Infrastructure means that you can take advantage of
the VA Series RTU 50 to interface to a wide varioty of
Intelligent field devices, and LAN/WAN connections to
maximize your SCADA investment,PSS 21H-8C1 B4
Page 3
FRONT PANEL LAYOUT
‘The ATU 50 Pil and PIIE front panels feature
diagnostics and interfaces to facilitate maintenance,
‘configuration, and communications. A Sense/Reset
(SEN/AST) switch allows the module to be hardware
reset or to enter low level diagnostics mode. The
FLASH memory card socket allows for the changing
of the FLASH card. Two serial ports are also
provided, with one serving as a configuration
diagnostics port and the other as serial interface.
Eight dlagnosticierror LEDs are provided to indicate
the status of diagnostic points and a RUN/FAIL LED
indicates module operation status.
On the PIIE, the dual 10BaseFL Ethernet board
provides additional LED indication for each fiber optic
‘Channel (light level, transmit, receive, jabber,
collision)
POWER SUPPLY
MODULE
, 1 ouTPur MopuLes—,
Pll Front Panel and PIIE Front Panel
i
[
a
BR
[——— eur mooutes ———
e
iS S
Eerereree fa
| dasren rcesson woos
pun cowsamocione ttsPSS 21H-8C1 B4
Page 4
PHYSICAL SPECIFICATION
Physical Size
Double Eurocard format
160 x 283.4 mm bare board
4182 x 261.8 x 30 mm including connectors and
handle
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature
(0°C to 60°C (optional -20°C to 70°C)
Humidity
10% to 95% RH (noncondensing)
FUNCTIONAL SPECIFICATIONS
Power Requirements
45 Vat 1.5 Amaximum, 1.0 Atypical
+15 V at 100 mA maximum, 15 mA typical
“15 at 200 mA maximum, 30 mA typical
Optional solection of +12 V and-12 V
Microprocessor
32-bit AM4B6DX4, 64 MHZ
Operating System
AMX
Bios
Foxboro protected made
Memory Modules
+ 128 KB FLASH (28F010)
+16 MB DRAM (EDO SIMI)
+ 4MB FLASH card expandable to 64 MB.
+ 32KB nonvolatile RAM
Poripheral Controllers
TL16C554 Quad UART
Custom chipset using Altera EPLD
Bus Specifications
Foxboro Electrobus
IEEE P996 Industrial PC/AT Bus
Watchdog Timer
1 second timeout to reset the RTU
Front Panel
RUNIFAIL LED
Eight diagnostic/etror LEDS
COM and COM? serial ports
Sense/Reset switch
FLASH memory card socket (PCMCIA)
Serial Ports
COMI - configurationidiagnostios
CON2 - GPS/IED/user serial interface
Electrical VF -DB9 male IBM PC compatible (DTE)
Real-Time Clock
IBM PCIAT compatible, Y2K compliant, with § ppm
accuracy, also generates Electrobus synchronizing
and SOE clocks
Backup Time
Real-time clock and non-volatile RAM are maintained
during power outage, via an on-board capacitor or an
optional lithium battery; up to 24 hours backup with
‘capacitor, or 8 years with the optional lithium batteryPSS 21H-8C1 B4
Page 5
PIE DUAL ETHERNET BOARD
Ports
‘Two 10 Mbps 10BaseFL Ethemet ports,
Interface
‘Two ST connectors (TX, RX) per port
TRANSMIT POWER
-15 dBm + 8 dB (-2 dB end of life)
RECEIVE LEVEL
“12 dBm to -$2.5 dBm for bil wior rate (BER)
of 109
RANGE
2000 m
WAVE LENGTH
820m
OPTICAL CABLE
‘Multimade glass fiber 62.5/125 um
Indicators
5 LEDe per port indicating link status (light level,
transmit, receive, jabber, colision)
Ethernet Chips
‘Two AM79C960 - PCnet-1SA Single Chip Ethernet
Controllers
‘Sharod Momory
‘32 KB RAM avallable per port
Physical Layer
HFBR-1414 Transmitter
HFBR-2416 Receiver
HFBR-4663 10BasoFL Transceiver
ORDERING INFORMATION
Part Number
s¥-0399066,
s¥-0399067
Description
ATU 50 Pll Master Processor Module
ATU 50 PIIE Master Processor Module with Dual 10BaseFL EthernetPSS 21H-8C1 B4
Page 6PSS 211-801 B4
Page 7PSS 21H-8C1 B4
Page 8
“The Foxboro Company
3 Commerc! Street
Focbore, Massocrusets 02035-2008
Unies Sates of Amerie
higivamfoxbora.com
Inside US. 1-506-543-8750 or 1-885-FOKBORO (1-888-960-2678)
Ouiside US: Caniat your local Foxboro representative
Foxboro and UA Series are registered vademarks of The Foxboro Company.
Inveneys is a vadorark of Iensys pe.
AM fa adomark of Kadak Prucs, Ld.
PCIAT fea trademar of IBM Corporation
Modbus is a tadamark of AEG Scinelder Automation, Ine.
CCopyeght 1987-2000 The Foxboro Company
‘A rights reserved
a.o21 Printed in USA
An invensys company
s00SECTION A-2
RTU C50 POWER SUPPLY
MODULEProduct Specifications
PSS 21H-8A8 B4
V/A Series® Remote Terminal Unit (RTU) _
RTU50 Power Supply Module
INTRODUCTION
Each W/A Seriss RTUSO catd file has a removable
Power Supply Module sized to support a fully
populated file.
‘The Power Supply Module is located in the frst slot of
each RTUSO file, This slot may be shared with the
Master Processor Module and/or a Communications.
Module or OptoNet Module.
The RTUSO Power Supply Module operates over a
vide input voltage 18 to 164 V de, negative or
positive earth, to accommodate the vast majority of
site battery backed supplies.
‘This module replaces the 24, 48 or 129 V de nominal
power supplies (Part Numbers S¥-0702041,
SY-0702042, and SY-0702054)
FEATURES
* Wide range inout supply: 18 to 164 V de positive
cor negative earthed
+ 100 W output capacity
* Supports a fully populated RTU 50 file with 50%
of 10 A relays operated simultaneously
+ High conversion efficionay
+ Withstands 4 ms dead shorted supply input
+ Built-in over-current and over/under voltage
protection
+ RTU systom failure alarm LED and contact
+ Control supply isolation input
* Loop power distribution terminals,
‘+ Power supply OK and Fail LEDs
FUNCTIONAL DESCRIPTION
‘The Wide Range 100 W Power Supply module
provides the regulated +5 V de, +15 V de, and
=15 V de operating supplies for an RTUSO file. A
41,000 V de supply is provided as an internal reference
{for automatic callbration of analog input modules.
“The module's switched mode design provides
operation over a wide de input range from 18 to
164 V, provides high input to output isolation, controls
switch-on inrush current, and minimizes size-to-
‘weight ratio, while offering high power conversion.
efficiency and high reliability
Internal monitoring provides a system reset to the
TU 50 modules should the +5 V supply be
abnormal. A front panel INPUT OK LED i
supply Is normal.
Monitoring of the 15 V rails Is indicated by 18 V
OK LED on the front panel
‘Avelay contact (normal open and normal closed)
controlled by the system fail and +15 V rail faut, is
avaliable on the front panel terminals,
icates the
Invensys”PSS 21H-8A8 B4
Page 2
Module Description
Each V/A Series RTUSO card file has a removable
Power Supply Module (see Figure 2), Because each
card fla has a dedicated power supply sized to
accommodate a fully equipped file, future expansion
within a file does not require any power supply
changes, while distributed power supplies enhance
availabilty. Rogardiess of the VO in an RTU, the
power supply is always correctly sized.
ELECTROBUS INTERFACE
WONTORS
AND
inoigarons
"ANALOG INPUT
Powen SYSFAL
GHeck voLTAge
SUPP RELAY DAIWER
deinpuT : 1)
4 I I
SURGE ouput
SUPPRESSION RELAY AND LED
i AND FILER INDICATOR,
I I
INPUT
‘ari
TERMINAL "NS TERMANALS
FUSE
POWER SUPPLY
MODULE
Figure 1. A Series RTUSO Power Supply Module Functional Block Diagram
[— ourput mopues —,———
INPUT MopuLES ————
i
Py
=
iS
Ho SEEHR
=
E
ai
Is
Tprororss Poamnone Y evvers I ramet
i
MASTER PROCESSOR MODULE
UAL COMMUNICATIONS MODULE
Figure 2. VA Series RTUSO Power Supply System, Example ImplementationPSS 21H-8A8 B4
Page 8
Front Panel
‘The I/A Series RTUSO Power Supply Module is
always located in the first sict of each file and may be
shared with the Master Processor Module andlor a
communications module (see Figure 3).
‘The module plugs into a backplane (Electrobus) via a
DIN 41612 connector and is double Eurocard size.
Front panel cutout allows a Dual Communication
Module or OptoNet Module to be fitted to Slot 1 of the
file (see Figure 2).
eo
‘The Power Supply Modules can be suppllad using &
24,48, or 129 V de power source,
‘The Power Supply Module provides contacts for an
external waming lamp or audible alarm to indicate an
TU or 15 V fault
Provision is also made for control supply isolation by
affixing an external switch of ele.
‘A pair of terminals provides connection of a remote
facility to isolate supply to control outputs
‘Atront panel power switch is provided.
Figure 3. Front Panel
PHYSICAL SPECIFICATIONS
Physical Size
‘The module requires frame space of 40 mm
190 x 262 x 40 mm assembly
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature
A0SC to +70°C
Humidity
10% to 95% (noncandensing)
Cooling
Natural convection, no forced cooling requiredPSS 21H-8A8 B4
Page 4
FUNCTIONAL SPECIFICATIONS.
Power Requirements
4130 W maximum input
Input Voltage
Wide range input voltage 18 to 164 V de
Suitable for use on 24 V de, 48 V de, and 128 V de
nominal source supplies
Output Capability
45 Val 108
HB5VatgA
15 Val 0.45 A
Maximum output of 100 watts total permitted
Input Current
7.2. Amaximum at 18 V
0.75 A maximum at 164 V
Efficiency
>75% at full load over full Input voltage range
Current Limit
Shutdown at maximum power with auto-recovery
Over-Voltage Protection
Crowbar protection set at 6.25 V
Under-Voltage Protection
‘Shutdown at low input voltage
Hold-up Time
‘Withstands 4 ms dead shorted power supply input
Ripple and Noise
50 mV peak-peak (+5 V)
400 mV peakpeak (215 V)
Isolation
2000 V ac RMS for 1 minute
Primary-to-Chassis and Primary-to-Secondary
Isolation
Transient Protection
IEC 255-4 class 3 (5 kV impulse, 2.5 kV HFD)
ANSI IEEE C37.90.1
IEC 61000-4-4 Level 3 (2 kV)
IEC 61000-4-5 Level 3 (2 kV)
EMC Conducted Noise
ENS0011 Class A
Fall Alarm Output
Relay output contact (normal open and normal
closed) controlled by Electrobus SYSFAIL signal and
#15 V ail fut
LED Indications
Input voltage OK, +15 V within limits
On Board Fuse
10 A250 V Type T, 20x 5 mm
ORDERING INFORMATION
Part Number
s¥-0702078
98 Commercial Sraet
Foxboro Massachusetts 02005-2099
United hates of America
‘wo fendorecom
Inte US: 1-000-740-0977
Description
RTUSO 100 W Wide Input Range Power Supply Module
(uiside U.S: 1-508-540-2424 or contact your local Foxboro represaalive
Facsimile: 1-808-540-4200,
Foxboro Austral
10 Brandl Street
Eight Mie Plains, Srisbane
Queensland 4173, ausraa
“Telephone: 461 7-s340-2111
Fax 461 73340-2100
levenays, Foxboro, and UA Saris are trademarks of Invensys pels subsilals, and afstes,
A oher brand namee may be trademarks of har raspacive owe.
Copyright 1007-2003 Invaneys Systen, Ine.
A rights resarved
Ms 021 Prinedin US.A, 403SECTION A-3
RTU C50 DUAL COMMUNICATION
MODULE