Bromma Technical Bulletin No:171
Author:           Leif Aveklint                                            Date (yy-mm-dd)      2017-07-03
                                                                                                Fredrik
Spreader type:         All with SCS4 and Midrange                          Approved by          Löwenhielm
Hydraluic                         Electrical                               Mechanical
Material                       General                                     Sales support
                  New CAN-filter for Cran com. SCS4 and Midrange
Topic:
CAN filter for crane communication BR1704458
The CAN filter is designed for mounting on a standard DIN-rail. It is designed to protect the
CAN bus against transients and faulty wiring.
This CAN filter will replace Polyswitch BR1027832, IFM cable with built-in resistor
BR1028280 and in some case also Phoenix Transient protection BR1020915/1020916
See picture below.
         .
The CAN filter automatically connects the CAN GND potential to
the same potential as the DIN-rail. If there is a need for DIN-rail
and CAN GND separation: simply remove the screw.
         The CAN filter has a built in CAN termination resistor (120ohm).
          The CAN termination can be enabled or disabled by sliding
         the DIP-switch in the ON or OFF position.
           ON = CAN termination enabled
           OFF = CAN termination disabled
                                                                            Please note that the earth
                                                                            connections “CAN GND” and
                                                                            “+VBB GND” must be
                                                                            connected to the same
                                                                            potential
    BR1027832
     BR1028280
BR1020915
BR1020916