AC Reactance: Multicore Cables

This document provides tables of typical AC reactance values in ohms per kilometer (Ω/km) for various sizes of copper and aluminum multicore and single core cables operating at 50Hz. The tables give reactance values for different cable insulation types, including PVC, XLPE and EPR, and cable conductor configurations including circular, shaped, flat and trefoil layouts. AC reactance depends on cable size, material, insulation and geometry.

Uploaded by

Sibi Varghese
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
461 views2 pages

AC Reactance: Multicore Cables

This document provides tables of typical AC reactance values in ohms per kilometer (Ω/km) for various sizes of copper and aluminum multicore and single core cables operating at 50Hz. The tables give reactance values for different cable insulation types, including PVC, XLPE and EPR, and cable conductor configurations including circular, shaped, flat and trefoil layouts. AC reactance depends on cable size, material, insulation and geometry.

Uploaded by

Sibi Varghese
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

AC Reactance

Typical AC reactances for copper and aluminium insulated cables operating at 50Hz are
based on values given in AS/NZS 3008.1.

Multicore Cables
AC Reactance (Ω\km)

Size (mm2) PVC XLPE


EPR
Circular (1) Shaped (1) Circular (1) Shaped (1)

1 0.119 - 0.139 0.114 -

1.5 0.111 - 0.129 0.107 -

2.5 0.102 - 0.118 0.0988 -

4 0.102 - 0.11 0.093 -

6 0.0967 - 0.104 0.0887 -

10 0.0906 - 0.0967 0.084 -

16 0.0861 0.0794 0.0913 0.0805 0.0742

25 0.0853 0.0786 0.0895 0.0808 0.0744

35 0.0826 0.0761 0.0863 0.0786 0.0725

50 0.0797 0.0734 0.0829 0.0751 0.0692

70 0.077 0.071 0.0798 0.0741 0.0683

95 0.0766 0.0706 0.079 0.0725 0.0668

120 0.0743 0.0685 0.0765 0.0713 0.0657

150 0.0745 0.0687 0.0765 0.0718 0.0662

185 0.0744 0.0686 0.0762 0.072 0.0663

240 0.0735 0.0678 0.0751 0.0709 0.0653

300 0.0732 0.0675 0.0746 0.0704 0.0649

400 0.0728 0.0671 0.074 0.0702 0.0647

500 0.0723 0.0666 0.0734 0.07 0.0645

Note (1): Circular or shaped refers to the conductor's cross-sectional shape

Single Core Cables


AC Reactance (Ω\km)
Size (mm2)
PVC EPR XLPE
Flat (1) Trefoil Flat (1) Trefoil Flat (1) Trefoil

1 0.184 0.168 0.194 0.179 0.181 0.166

1.5 0.172 0.157 0.183 0.167 0.17 0.155

2.5 0.159 0.143 0.168 0.153 0.156 0.141

4 0.152 0.137 0.157 0.142 0.146 0.131

6 0.143 0.128 0.148 0.133 0.138 0.123

10 0.134 0.118 0.138 0.123 0.129 0.114

16 0.126 0.111 0.13 0.114 0.122 0.106

25 0.121 0.106 0.125 0.109 0.118 0.102

35 0.117 0.101 0.12 0.104 0.113 0.0982

50 0.111 0.0962 0.114 0.0988 0.108 0.0924

70 0.107 0.0917 0.109 0.0941 0.104 0.0893

95 0.106 0.0904 0.108 0.0924 0.102 0.0868

120 0.102 0.087 0.104 0.0889 0.0996 0.0844

150 0.102 0.0868 0.104 0.0885 0.0996 0.0844

185 0.101 0.0862 0.103 0.0878 0.0988 0.0835

240 0.0999 0.0847 0.101 0.0861 0.097 0.0818

300 0.0991 0.0839 0.1 0.0852 0.0961 0.0809

400 0.0982 0.0829 0.0993 0.0841 0.0955 0.0802

500 0.0973 0.082 0.0983 0.083 0.0948 0.0796

630 0.0952 0.08 0.0961 0.0809 0.094 0.0787

Note (1): Single core cables are laid flat and touching