Footing F 5,7: Q P A My I

This document provides design calculations for the footing of a residential building. It includes: 1) Checking the soil pressure and determining it is below the allowable limit. 2) Checking the footing thickness for punching shear and determining it meets the capacity. 3) Checking the one-way shear at a critical section and determining it meets the capacity. 4) Designing the reinforcement for flexure and determining the required reinforcement ratio, which is satisfied using 4 #12 bars at 200mm spacing.

Uploaded by

aberra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views5 pages

Footing F 5,7: Q P A My I

This document provides design calculations for the footing of a residential building. It includes: 1) Checking the soil pressure and determining it is below the allowable limit. 2) Checking the footing thickness for punching shear and determining it meets the capacity. 3) Checking the one-way shear at a critical section and determining it meets the capacity. 4) Designing the reinforcement for flexure and determining the required reinforcement ratio, which is satisfied using 4 #12 bars at 200mm spacing.

Uploaded by

aberra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 5

Project Residential Building Date

Description Footing Design By


Chkd

FOOTING F 5,7
619 kn

25 30 kn-m

Col Size 0.3 x 0.3

t = 0.45

d = 0.415 Critical Sections

1.6 m
d/2 = 0.2075

1.6 m

Step 1 - Check Soil Pressure

Pressure from Self Weight of Ftg = 11.25 Kpa

Net Allowable Soil Pressure = 299 Kpa

e = 0.048 < L
6
P My
q= ±
A I
P = 619 = 241.8 Kpa
A 2.56

My = y = 0.8 m
I I = 0.55 m4

= 43.95 Kpa

q = 285.7 Kpa OK
q = 197.9 Kpa OK

F1
Project Residential Building Date
Description Footing Design By
Chkd

FOOTING F 5,7

Step 2 - Check Thickness

Check Punching Shear

Tributary Area for


Punching Shear

1.6 m
d/2 = 0.2075

1.6 m

Pressure = 241.80 Kpa


Trib. Area = 2.05 m2
Shear = 495.39 KN

Punching Shear Capacity of Footing

V RD =0 . 5 f ctd ( 1+50 ρ ) ud
Assumptions:
As = f 20 @ 200
Critical Section Occurs at d/2 (Note: EBCS say critical section is at
1.5d, which contradicts all text books
Therefore, use d/2)

fctd = 1133 kpa


d = 0.415 m
r = 0.00373
u = 2.86

= 797.9436 KN OK

F1
Project Residential Building Date
Description Footing Design By
Chkd

FOOTING F 5,7

Check one-way Action d = 0.415

Tributary Area for


one-way action

1.6 m

1.6 m

Calculate Shear @ Critical Section

197.9

285.7 Kpa

Critical Section From Edge of Footing is = 0.235 m


Pressure At Critical Section is = 272.8333 Kpa
Shear At Critical Section is = 119.1087 Kn

Shear Capacity of Section

V c=0 .25 f ctd k 1 k 2 b w d


fctd = 1133
K1 = (1+50r)
r = 0.00373
= 1.19
d = 0.415
K2 = 1.6 -d = 1.185
bw = 1.60

F1
Project Residential Building Date
Description Footing Design By
Chkd

FOOTING F 5,7
= 264.49 Kn OK

Step 3 - Design for Flexure

197.9

285.7

Critical Section For Moment

Critical Section From Edge of Footing is = 0.65


Pressure At Critical Section is = 250.04 Kpa
Moment At Critical Section is = 57.84877 Kn - m/m

Calculate Reinforcement

ρreq =
1
m[ √
1− 1−
2 mR n
f yd ] ; m=
f
f
yd

cd
; Rn =
Mu
bd 2

fcd = 13600 Kpa


fyd = 347826.00 Kpa
d = 0.415 m
b = 1.00 m

m = 25.58
Rn = 335.89

= 0.0009779 use 0.00125

F1
Project Residential Building Date
Description Footing Design By
Chkd

FOOTING F 5,7
As = 0.00052 = 4.587 Dia 12 bars
Use f 12 @ 200