0% found this document useful (0 votes)
245 views2 pages

Carbon Monoxide DM-100-CO PDS

The document describes the Detcon Model DM-100-CO carbon monoxide sensor. It is an electrochemical sensor that detects CO from 0-100 ppm using a 4-20 mA output signal. The sensor has features like intrinsic safety, weatherproofing, diagnostics and replaceable components to work in industrial environments.

Uploaded by

royvindas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
245 views2 pages

Carbon Monoxide DM-100-CO PDS

The document describes the Detcon Model DM-100-CO carbon monoxide sensor. It is an electrochemical sensor that detects CO from 0-100 ppm using a 4-20 mA output signal. The sensor has features like intrinsic safety, weatherproofing, diagnostics and replaceable components to work in industrial environments.

Uploaded by

royvindas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Model DM-100-CO

detcon inc. Carbon Monoxide Sensor

GAS DETECTION SENSORS INTEGRATED CONTROL SYSTEMS SMARTWIRELESS® PIPELINE ANALYZERS ALARMS

Description
Detcon Model DM-100-CO is a gas detection sensor designed to detect and
monitor Carbon Monoxide in air over the range of 0-100 ppm using electro-
chemical sensor technology. Method of detection is by diffusion adsorption. Air
and gas molecules diffuse through a porous membrane contacting an electrolyte
solution which creates a change in electrical conductance between a reference
and measure electrode. This change in conductance is conditioned by internal
electronic circuitry to provide a linear 4-20 milliamp signal proportional to the
gas concentration.
Model DM-100 Series sensors feature intelligent electronics, non-intrusive
operator interface and comprehensive fault diagnostics. The sensor is packaged
in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT
thread. The plug-in, field replaceable sensor cell features large surface area
gold-plated pins that reduce the effects of corrosion in harsh industrial environ-
ments. Signal conditioning electronics are completely encapsulated in the sensor
housing adding a high level of durability to the design. The packaging is
XP-intrinsically safe. This innovative design marks a return to a simple, more
affordable, and durable gas detection sensor without compromising quality. CO
100 PPM
Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal
equivalent to the sensor range of detection. Upper enclosure options are alumi-
num and stainless steel (includes a transient protection terminal board). Addi-
tional accessories include wireless communications, a loop powered digital
display, Remote Alarm Module (RAM), HART, and a current to RS-485
converter. The standard serial converter is Modbus RTU. Each sensor is shipped
with a splash guard with integral calibration port. Detcon’s toxic gas sensors
have a long shelf life and are supported by an industry-leading warranty.

Features Applications
XP-intrinsically Safe Design Oil & Gas
NEMA 4X Weatherproof & NEMA 7 Explosion Proof Chemical Plants
Class I, Div. 1, Groups A, B, C, & D Food and Beverage (shown as PN 961-440022-100 in Aluminum j-box
with Loop Powered Display)
2 Wire Loop-powered Steel Mills
Field Replaceable Electrochemical Sensor Pulp and Paper
Non-intrusive Magnetic Interface Refineries
Built-in Diagnostics Wastewater Treatment Plants
Fully Encapsulated Electronics Utilities
Electropolished 316SS Construction
Quick Thread Release (for sensor replacement)
Integral Calibration Port

www.detcon.com
Model DM-100-CO Carbon Monoxide Sensor
R061611

System Specifications Mechanical Specifications


Sensor Type Dimensions
Continuous diffusion/adsorption 7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
3-electrode electrochemical cell 11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Plug-in field replaceable Type Mechanical Connection:
Measurement Range 3/4” male NPT threaded connection with locking nut
0-100 ppm, Other ranges available Electrical Connection:
Four 18 gauge wire leads - 5.5” long
Accuracy/Repeatability Mounting holes (with J-box) 5.5" (140mm) center to center
±2% FS
Weight
Response/Clearing Time 2 lbs; 0.907kg (sensor only)
T90 ≤30 seconds 6 lbs; 2.72kg (w/aluminum j-box)
Span Drift 9 lbs; 4.08kg (w/stainless steel j-box)
<5% signal loss per Year
Outputs Electrical Specifications
Linear 4-20 mA DC
Power Input
Electrical Classification 10-28 VDC
Explosion proof
CSA and US (NRTL) Power Consumption
Class I, Division 1, Groups A, B, C, D (Tamb = -40°C to +50°C) Normal operation = 4mA (0.1 watts @ 24VDC)
Class I, Zone 1, Group IIC Maximum = 20mA (0.5 watts @ 24VDC; 0.23 watts @ 11.5VDC)
ATEX RFI/EMI Protection
II 2 G Ex d [ib] ib IIC T4 (Tamb = -40°C to +50°C) Complies with EN61362
II 1 G Ex ia II C T4 (with IS barrier installed) Analog Output
Ingress Protection Linear 4-20mA DC (750 ohms max loop load @ 24VDC)
NEMA 4X, IP66 1.2mA All Fault Diagnostics (without display)
Safety Approvals 3mA All Fault Diagnostics (with display)
CCSAUS
4-20mA 0-100% full-scale
ATEX 22mA Over-range condition
CE Marking (Pending) Serial RS-485 Output (optional)
Sensor Life/Warranty RS-485 Modbus™ RTU
Plug-in cell - 3 years; Transmitter - 2 Years Baud Rate (optional)
9600 BPS (9600,N,8,1 Half Duplex)
Environmental Specifications Status Indicators
4-digit LED display with gas concentration & fault (optional)
Operating Temperature Range
-40°F to +122°F; -40°C to +50°C Faults Monitored
Missing Sensor, Zero,
Storage Temperature Range Calibration, Temperature
-31°F to +131°F; -35°C to +55°C (typical)
Cable Requirements
Operating Humidity Range Power/Analog
15% to 90% RH non-condensing (continuous) 2-wire shielded cable
5%-100% RH (intermittent) Maximum distance is 13,300 feet with 14 AWG
Operating Pressure Range Serial Output (optional)
Atmospheric ±10% 2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
Specifications subject to change without notice I/O Protection
Over-voltage, Miswiring, EMI/RFI Immunity

Order Guide Accessories


961-440025-100 DM-100-CO (no junction box) Junction Box (aluminum or 316-SS with Transient Protection Terminal Board)
961-440021-100 DM-100-CO with aluminum j-box Loop Powered Digital Display (Provides a Direct Display of Sensor Readings)
961-440023-100 DM-100-CO with 316 SS j-box Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault)
961-440022-100 DM-100-CO with alum j-box & loop powered display Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered)
961-440024-100 DM-100-CO with 316 SS j-box & loop powered display Current to RS-485 Converter (Modbus RTU)
Wireless Communications (Detcon Model RXT-320 SmartWireless® Transceivers)

Houston Odessa Shanghai Dammam Del Carmen Europe

Tel: 713-559-9200
Toll Free: 888-367-4286 ISO 9001: 2008
Fax: 281-292-2860
Email: [email protected] Certified
detcon inc. Web: www.detcon.com

You might also like