Innovus addTieHiLo

The addTieHiLo command adds tie-off cells to the design hierarchy and connects the tie pins of instances to the tie pins of the added cells. This provides connectivity between the tie-high and tie-low pins of instances to power and ground. It can add tie cells to specific or all power domains and allows specifying tie cell names, prefixes, and other options.

Uploaded by

sagar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
982 views2 pages

Innovus addTieHiLo

The addTieHiLo command adds tie-off cells to the design hierarchy and connects the tie pins of instances to the tie pins of the added cells. This provides connectivity between the tie-high and tie-low pins of instances to power and ground. It can add tie cells to specific or all power domains and allows specifying tie cell names, prefixes, and other options.

Uploaded by

sagar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

addTieHiLo

addTieHiLo
[-cell { tieHighCellName tieLowCellName} | -cell tieHighLowCellName ]
[-createHierPort {true | false}]
[-matchingPDs {true|false}]
[-postMask {true | false}]
[-powerDomain powerDomainName ]
[-prefix prefixName ]
[-reportHierPort {true | false}]
Adds instances of specified tie-off cells to the logical hierarchy of the design and connects the tie-off pins of
netlist instances to the tie-off pins of the added instances. Thus, these instances provide the connectivity
between the tie-high and tie-low pins of the netlist instances to power and ground. Use this command after
placing the standard cells in the flow.
Note: If you omit the -powerdomain option, the command will insert tie-hilo on default power domains.
To add tie-off cells to all domains, you need to use the -matchingPDs option.
Note: If you do not specify parameters, this command uses the global parameters specified by
the setTieHiLoMode command.

Parameters
-cell cellNames Specifies the tie cells to add.
You can only specify a maximum of two tie-cells, where
one cell must be a tie-high driver, and the other a tie-low
driver. The two tie-cell names must be surrounded by
quotation marks.
This parameter overrides cell name(s) specified by
the setTieHiLoMode command.
Default: "" (empty string)
-createHierPort {true | Allows the added tie cells to connect to tie pins across
false} hierarchical boundaries if other constraints, such as
maximum fanout and maximum distance, allow it.
Default: false
-matchingPDs {true|false} Adds tie-off cells to all power domains that have library
binding containing the specified tie-off cell(s).
Default: false
-postMask {true | false} Insert tie cells in post mask flow. Instructs the software to
reuse existing tie cells to tie off a newly created spare
instance in the design instead of adding or deleting tie
cells. Searches for input pins that are tied to logical 1 or
logical 0 and attempts to tie them off to tie high or tie low
cells.
Default: false
- Inserts tie-off cell to the named PD.
powerDomainpowerDomainName
Default: "" (empty string)
Note: When this option is not specified, tool only inserts
tie cells in the "default" power domain
-prefixprefixName Specifies a prefix for the added tie-cell instances.
Default: "" (empty string)
-reportHierPort {true | When the value of -createHierPort is true , reports
false}
created port connections to a file namedtiehilo.rpt .
Default: false

Examples

 The following command adds tie-high and tie-low connectivity for designs with libraries that have cell
named TIEOFF that provides both tie-high and tie-low connections. The instances added are prefixed
with tieOff :
addTieHiLo -cell TIEOFF -prefix tieOff

 The following command adds tie-high and tie-low connectivity for designs with libraries that have separate
tie-high and tie-low cells namedTIEHI and TIELO respectively:
addTieHiLo -cell "TIEHI TIELO"

 The following commands add tie-off connectivity for MSV designs with two power domains
named PD1 and PD2 . The last command is necessary for the part of the design that is not in either of the
two specified power domains.
addTieHiLo -cell "TIEHI TIELO" -powerDomain PD1
addTieHiLo -cell "TIEHI TIELO" -powerDomain PD2
addTieHiLo -cell "TIEHI TIELO"

The following commands add tie-off connectivity for MSV designs where all power domains whose library
binding contains TIEOFF cell:
addTieHiLo -cell TIEOFF -matchingPDs true