78510908V01 | Page 1 of 3

K-BOW
Outdoor Power Supply Unit PSU
150 W
▪▪ Universal AC input / full range (up to 305 V AC)
▪▪ Built-in active PFC function
▪▪ High efficiency up to 94%
▪▪ Fanless design, cooling by free air convection
▪▪ −55 to +70 °C wide operating temperature range
▪▪ Aluminium case and filling with heat-conducted silicone
▪▪ IP68 for wet outdoor applications
▪▪ Meets 6 kV surge immunity level
▪▪ Withstands 10G vibration test
▪▪ Protections: short circuit, overload, overvoltage,
overtemperature
▪▪ Operating altitude up to 5000 meters 1)

The outdoor PSU is a 150 W industrial AC/DC power supply


featuring the outstanding capability to operate under highly
humid, dusty, oily, and high-vibration harsh environment. The
PSU is housed with the aluminium case and fully potted with
heat-conducted silicone. Thanks to state-of-the-art design, Remarks
the working efficiency is up to 94%, enabling the PSU perfectly
work between −55 °C and +70 °C under free air convection. Ordering information
▪▪ Outdoor power supply unit
150 W: 78510908V01
Specifications
Scope of delivery
Electrical input
▪▪ 1 outdoor power supply unit
Voltage range V AC 90 to 305 in carton
VDC 127 to 431

936.X002/b/1017 | Subject to change  Copyright © Kathrein Solutions GmbH 2017 All rights reserved
Frequency range Hz 47 to 63
Power factor typ. > 0.98 @ 115 V AC,
typ. > 0.95 @ 230 V AC
typ. > 0.92 @ 277 V AC at full load
Efficiency % typ. 94
Inrush current A 65 @ 230 V AC, cold start
Electrical output
Output voltage V 48 ± 1%
Rated current A 3.2
© 2017 KATHREIN Solutions GmbH
Rated power W 153.6 The reproduction, distribution
and utilisation of this document
Ripple and noise 2) mVpp 200
as well as the communica-
Overload protection 3) % 105 to 125 tion of its contents to others
without express authorisation
Short-circuit protection 3) yes
is prohibited. Offenders will be
Overvoltage protection 4) V 54 to 63 held liable for the payment of
damages. All rights reserved in
the event of the grant of a pat-
ent, utility model or design.
KATHREIN Solutions GmbH, Anton-Kathrein-Straße 1-3, 83004 Rosenheim, Germany
Phone +49 8031 184-0 | www.kathrein.com | [email protected]
78510908V01 | Page 2 of 3

Mechanical specifications
Dimensions (W × H × D)
PSU only mm 228 × 68 × 38.8
PSU package mm 250 × 75 × 50
Weight
PSU only g 1075
PSU package g 1150
DC port connector type open cable 2 x SJTW 14AWG; see Fig. 4, p. 3
Environmental specifications
Operating temperature °C −55 to +70
derate linearly from 100% power @ +60 °C to
60% power @ +70 °C; see Fig. 2, p. 3
Storage temperature °C −60 to +80
Cooling convection-cooled
Operating humidity % 5 to 95 relative humidity, non-condensing
Operating altitude m ≤ 3000
Ingress protection class IP68

All specifications are compliant to the relevant parts of the following standards:
▪▪ Emissions EN55011/22, class B conducted
EN55011/22, class B radiated
▪▪ Harmonic currents EN61000-3-2, class A
▪▪ Voltage flicker EN61000-3-3
▪▪ ESD immunity EN61000-4-2, level 3, Perf Criteria A
▪▪ Radiated immunity EN61000-4-3, level 3, Perf Criteria A
▪▪ EFT/burst EN61000-4-4, level 3, Perf Criteria A
▪▪
936.X002/b/1017 | Subject to change  Copyright © Kathrein Solutions GmbH 2017 All rights reserved
Surge EN61000-4-5, installation class 3, Perf Criteria A
▪▪ Conducted immunity EN61000-4-6, level 3, Perf Criteria A
▪▪ Magnetic field EN61000-4-8, level 3, Perf Criteria A
▪▪ Dips and interruptions EN61000-4-11, EN60601-1-2
▪▪ Safety approvals EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No. 60601-1 per cUL, including risk management,
EN60950, UL60950. Denan (PSE) certification

1) The ambient temperature derating of 3.5 °C / 1000 m is needed for operating altitude greater than
2000 m (6500 ft).
2) Ripple and noise are measured at 20 MHz of bandwidth by using a 12" twisted pair-wire terminated
with a 0.1 µF and 47 µF parallel capacitor.
3) Protection type: constant current limiting, recovers automatically after fault condition is removed
4) Protection type: shut down output voltage with auto-recovery or re-power on to recovery

KATHREIN Solutions GmbH, Anton-Kathrein-Straße 1-3, 83004 Rosenheim, Germany


Phone +49 8031 184-0 | www.kathrein.com | [email protected]
78510908V01 | Page 3 of 3

F osc : 100 kHz


EMI FILTER PFC POWER RECTIFIERS +V
I/P & SWITCHING &
CIRCUIT -V
RECTIFIERS FILTER
O.L.P.

FG O.L.P. DETECTION
PFC PWM CIRCUIT
CONTROL CONTROL
O.T.P.
O.V.P.

Fig. 1: Block diagram

100
100
90

80
80

60 70
LOAD (%)

60
LOAD (%)

40
50

20
40

-55 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 305

AMBIENT TEMPERATURE (℃) INPUT VOLTAGE (V) 60Hz

Fig. 2: Derating curve Fig. 3: Static characteristic

228
12 204
9.6
9.4

300±20
FG (Green/Yellow) T case
34.2

102 300±20
68

AC/L(Brown)

936.X002/b/1017 | Subject to change  Copyright © Kathrein Solutions GmbH 2017 All rights reserved
AC/N(Blue) SJTW 18AWG×3C -V(Black)
+V(Red)
34
9.4

SJTW 14AWG×2C
ψ4.2×4PL

※ T case: Max. Case Temperature.


38.8

※IP68 rated. Cable for I/O connection.


Fig. 4: Mechanical specification

File Name:HEP-150-SPEC 2016-02-18

File Name:HEP-150-SPEC 2016-02-18

KATHREIN Solutions GmbH, Anton-Kathrein-Straße 1-3, 83004 Rosenheim, Germany


Phone +49 8031 184-0 | www.kathrein.com | [email protected]

You might also like