Valve Symbols Pipe and Fitting Symbols: Double Line Single Line
Valve Symbols Pipe and Fitting Symbols: Double Line Single Line
APVD
RESULTING FROM THE CONTRACTOR’S OPERATIONS SHALL BE REPAIRED AT THE
A
CONTRACTOR’S EXPENSE. WHERE CROSSING OF EXISTING UTILITIES OCCUR, PROVIDE BALL
12" MINIMUM CLEARANCE EXCEPT WATER MAINS SHALL BE 18". CROSS UNDER ALL WATER EXISTING PIPE TO BE REMOVED
MAINS WHERE NOT POSSIBLE TO PROVIDE 16" CLEARANCE. MISCELLANEOUS PIPING SYMBOLS
BY
2. MINIMUM COVER OVER PIPING SHALL BE 3’-0", BELOW FINISHED GRADE.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF
UNLESS OTHERWISE SHOWN OR NOTED. WELDED JOINT SEATING PORT
CH2M HILL AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CH2MHILL.
STRAINER
3. PROVIDE MINIMUM PIPE COVER, AS SPECIFIED. GENERALLY LAY PIPE TO UNIFORM GRADES
APVD
ECCENTRIC PLUG
BETWEEN THE ELEVATIONS SHOWN, UNLESS OTHERWISE APPROVED. IN SOME CASES,
GROOVED END JOINT
EXISTING CONDITIONS PROHIBIT UNIFORM GRADES BETWEEN THE ELEVATIONS SHOWN, SIGHT GLASS
PLUG OR COCK
AND FIELD ADJUSTMENTS TO UNIFORM GRADES ARE REQUIRED AS APPROVED.
S BIANCHETTA
4. SIZE OF FITTINGS SHOWN ON PLANS SHALL CORRESPOND TO ADJACENT STRAIGHT RUN FLANGED JOINT GAUGE WITH COCK
OF PIPE, UNLESS OTHERWISE INDICATED. TYPE OF JOINT AND FITTING MATERIAL SHALL BE
THE SAME AS SHOWN FOR ADJACENT STRAIGHT RUN OF PIPE.
BACKFLOW PREVENTER
5. LOCATION AND NUMBER OF PIPE HANGERS AND PIPE SUPPORTS SHOWN IS ONLY MECHANICAL JOINT
APPROXIMATE. CONTRACTOR SHALL DESIGN SUPPORTS AS SPECIFIED.
REVISION
6. ALL JOINTS SHALL BE WATERTIGHT. WALL PIPES SHALL BE USED WHEREVER REDUCER
CHK
PIPING PASSES FROM A STRUCTURE TO BACKFILL. BELL & SPIGOT JOINT (LEADED) SWING CHECK
7. ALL FLEXIBLE CONNECTORS AND FLANGED COUPLING ADAPTERS SHALL BE PROVIDED WITH FLEXIBLE HOSE BALL CHECK
K TROSPER
THRUST TIES AND ANCHORS, UNLESS OTHERWISE NOTED. THRUST PROTECTION
HUB & SPIGOT JOINT
SHALL BE ADEQUATE FOR TEST PRESSURES SPECIFIED.
HOSE VALVE (HV- X) OR (V-X)
(RUBBER GASKET)
8. SYMBOLS, LEGENDS, AND PIPE USE IDENTIFICATIONS SHOWN SHALL BE FOLLOWED X = NO. IN SPECS
THROUGHOUT THE PLANS, WHEREVER APPLICABLE. NOT ALL OF THE VARIOUS PIPING
BALL JOINT
COMPONENTS ARE NECESSARILY USED IN THE PROJECT. S SAMPLE
9. ALL BURIED PIPING SPECIFIED TO BE PRESSURE TESTED, EXCEPT FLANGED, WELDED, OR ADAPTER SIDE GATE SYMBOLS
SCREWED PIPING, SHALL BE PROVIDED WITH THRUST RESTRAINT. THRUST RESTRAINT FOR GROOVED END ADAPTER FLANGE
DR
NEW PIPING SHALL BE AS SPECIFIED IN SECTION 15200.
B 10. NUMBER AND LOCATION OF UNIONS SHOWN ON PLANS IS ONLY APPROXIMATE. PROVIDE
ELEVATION VIEW PLAN VIEW PRESSURE RELIEF
K TROSPER
ALL UNIONS NECESSARY IN THE OPINION OF THE ENGINEER TO FACILITATE CONVENIENT FLANGED COUPLING ADAPTER
REMOVAL OF VALVES AND MECHANICAL EQUIPMENT.
AIR AND/OR VACUUM RELEASE
11. WHERE A GROOVED END COUPLING IS SHOWN, IT SHALL BE THE RIGID JOINT TYPE, UNLESS
DATE
SLUICE
OTHERWISE SPECIFIED. WHERE A FLANGED COUPLING ADAPTER IS SHOWN, A STANDARD FLEXIBLE COUPLING
REGULATED SIDE
FLANGE SHALL BE JOINED TO THE COUPLING ADAPTER.
DSGN
PRESSURE CONTROL
NO.
METAL BELLOWS EXP JOINT BUTTERFLY
REGULATED SIDE
CITY OF PHARR
PHARR, TEXAS
E OR M ELECTRIC MOTOR S SOLENOID
ELBOW DOWN
DOUBLE LINE SINGLE LINE
MANUAL VALVES AND CHECK VALVES
EXISTING PIPE TEE UP
REUSE OF DOCUMENTS:
8" - V 500
SIZE OF VALVE
C EXISTING PIPE TO BE ABANDONED LATERAL UP
PIPING DESIGNATION VALVE DESIGNATION
EXAMPLE:
4" W1 VALVE TYPE, SEE
EXISTING PIPE TO BE REMOVED LATERAL DOWN
SPECIFICATION
SECTION 15202
MECHANICAL LEGEND
ECCENTRIC REDUCER (SEE INSTRUMENTATION AND CONTROL LEGEND)
NON-FREEZE HOSE VALVE X
PIPE DIAMETER
WITH HOSE RACK (V-X)
X = NO. IN SPECIFICATIONS REDUCING BUSHING
FLOW DIRECTION
VALVE SYMBOL
GENERAL
GATE VALVE UNION
* BUBBLE WITH FUNCTION AND THE
BUTTERFLY VALVE CAP TAG NUMBER DESIGNATION
(SEE I&C LEGEND FOR TAGGING INSTRUMENT IDENTIFICATION)
SEATING
FLOW
PORT
ECCENTRIC PLUG VALVE
ANCHOR
ELBOW, 90 DEGREE
FIRE HYDRANT
PROJ 323362
LATERAL
DWG G-6
SHEET 6