0% found this document useful (0 votes)
105 views

Loadings Poultry

This document provides loadings and design parameters for structural elements. It includes purlin and truss spacing, dead and live loads from roofing and occupancy, and wind and seismic load values. Wind loads are given for three zones and seismic loads include factors for soil type, structure importance, and code used. Dimensions of the main building are also listed along with parameters for calculating wind design pressure.

Uploaded by

Jems Mansueto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views

Loadings Poultry

This document provides loadings and design parameters for structural elements. It includes purlin and truss spacing, dead and live loads from roofing and occupancy, and wind and seismic load values. Wind loads are given for three zones and seismic loads include factors for soil type, structure importance, and code used. Dimensions of the main building are also listed along with parameters for calculating wind design pressure.

Uploaded by

Jems Mansueto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

Loadings

Purlin Spacing 0.75 m


Purlin Design
Truss Spacing 5 m
Dead Loads
Self Weight of Purlins VARIES
Corrugated Roofing 0.1 kN/m2 0.075

Live Loads
Roof Live Load 0.5 kN/m2 0.375

Wind Loads

Zone 1
2.48 -2.48 kN/m2 10% least horizontal dimension 0.8
Zone 2 0.4h 6.975
2.48 -3 kN/m2 4% least horizontal dimension 0.32
0.9 0.9
Zone 1
1.86 -1.86 kN/m Purlin Effective Area 8.33333333
Zone 2
1.86 -2.25 kN/m
Truss Design

Dead Loads
Corrugated Roofing
kN/m C10x15 Purlins
MEP Utilities

Live Loads
kN/m Roof Live Load

Wind Loads

Zone 1
2.48 -2.48 kN/m2
Zone 2
2.48 -3 kN/m2
GOVERNS Zone 3
2.48 -3 kN/m2
m2
Zone 1
12.4 -12.4 kN/m
Zone 2
12.4 -15 kN/m
Zone 3
12.4 -15 kN/m
Total Length of Purlins 90 m
Purlin Spacing 0.75 m
Truss Spacing 5 m

0.1 kN/m2 0.5 kN/m


19.983 kN 1.480222222 kN/m2
0.1 kN/m2 0.5 kN/m

0.5 kN/m2 0.375 kN/m

10% least horizontal dimension 0.8


0.4h 6.975
4% least horizontal dimension 0.32
0.9 0.9 GOVERNS

Truss Effective Area 40 m2


Frame Design
Dead Loads
Self Weight of Structure VARIES

Live Loads
Walkway (Public Access) 7.2 kPa
Storage (Facilities for Poultry House) 2.5 kPa

Wind Provisions

Common
Coherent Code ASCE 7-2010
Building Classification Category Category I
Basic Wind Speed 300 kmph
Exposure Category Exposure B
Structure Type Building Structures

Main Building Data


Building Height 8.15 m
Building Length along the direction
8m
of Wind
Building Length Normal to the
90 m
Direction of Wind
Building Natural Frequency 2
Building Damping Ratio 0.01
Enclosure Classification Partially Enclosed

Building Design Pressure


G 0.795
Cp 0.8
Gcpi -0.55

Seismic Provisions
Coherent Code UBC 1997
Zone 0.4
Importance Factor 1
Rw in X-Direction (RWX) 8.5
Rw in Z-Direction (RWZ) 8.5
Soil Profile Type 4
Near Source Factor (Na) 1
Near Source Factor (Nv) 1
CT Value 0.0731
Note: Includes Accidental Loads
12.5 kN/m
2.875 kN/m

You might also like