Establish the new standard of
Partida 11 y 12 digital ultrasound scanner
ORA: dynamic receiving apodization
DRF: dynamic receiving focusing
ROA: real-time dynamic aperture
DFS: digital frequency sean
DBF: digital beam forming
THI: tissue harmonic imaging
Digital wave filter
HM- 310
7215 N.W. 46TH Street Miami Florida 33166 U.S.A.
P: +1 305 594 7474 F: +1 305 477 0699
[email protected] www.hill-med.com
HM- 310
Portable Ultrasonic Diagnostic System
Technical Specification
Applícation Abdomen, OB&GYN, Small parts, Urology, Cardiology, Pediatrics etc.
Scanning Method Electronic Convex/ Electronic Linear/ Electronic micro-convex
Displaying Mode B, B/B, 48, B/M, M
Focusing ontinuous Oynamic Focusing, acoustic lens focusing
age persist, edge enhancemenUsmooth, ORF,grey scale adjustable, image left/right inversion, image
lmage Processing up/down inversion,image positive/negative inversion, eight slides STC, M mode
speed, linedensity selection, line frame frequency, scanning angle/width.
Acoustic Power Multilevel and adjustable
lmaging Techniques OBF, ORA, ORF, OFS, ROA,THI
Grey Scale 256
General B Mode: distance,circumference,area,angle,volume,% stenosis,histogram
Measurements M Mode: heart rate, time, distance, velocity
08 software Four database for calculating pregnant weeks: ( one for user-defined} GS. BPO. CRL. FL. HL .
k TAO . LV , OFO . AC . HC , etc. AFI, Fetal weight, Ratio, LMP. BBT, fetal growth curve, Fetal
pac age Biophysical Score,OB report
GYN software package Measurement and calculation for uterus, ovary, follicle,GYN report
Urology software package Measurement and calculation for kidney, bladder, residual urine volume ,Urology report
Andrology software package Measurement and calculation for Prostate, testicle,Calculation for PPSA. PSAO,Andrology report
Cardiology Software Package Heart rate, velocity, LV, RV, aortic valve, mitral valve,Cardiology report
Body Mark Abdomen, Andrology, Cardiology, Gynecology, Musculoskeletal, Obstetrics,Pediatric, Small part, Urology
Cine Loop Large capacity of cine loop automatically or manually. Cine loop speed adjustable
lmage Storage Storage for single image in formalof BMP, JPEG. PNG, OICOM etc; storage for cine loop in AVI
Interfaces SVGA. USB. interne! port. OICOM 3.0
Probe Multi-frequency probe with 5 steps, 2 probe connectors.
Power Supply 220v(±10%)AC 50Hz (standard} 110v((±10%) AC 60Hz (upon the request)
Standard Configuration Main unit, 3.5MHz convex probe, 10" monitor
3.5MHz micro-convex nrohP.
Optional Configuration 6.5MHz vaginal probe
7.5MHz high-frequency linear probe
Trolley, video printer, laser printer, ink jet printer
Workstation