0% found this document useful (0 votes)
299 views2 pages

Alpha 4812 2009 PDF

The document summarizes a fire alarm control panel called the ALPHA 4/8/12. It can support between 4 to 12 detection zones and 1 to 2 extinguishing zones. The panel is microprocessor controlled and programmable. It also supports the addition of optional modules to extend its detection zones up to 12 zones or up to 2 extinguishing channels. The panel's main characteristics include the number of detection lines, relays, inputs/outputs, and optional modules for expansion.

Uploaded by

Adrian Oprisan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
299 views2 pages

Alpha 4812 2009 PDF

The document summarizes a fire alarm control panel called the ALPHA 4/8/12. It can support between 4 to 12 detection zones and 1 to 2 extinguishing zones. The panel is microprocessor controlled and programmable. It also supports the addition of optional modules to extend its detection zones up to 12 zones or up to 2 extinguishing channels. The panel's main characteristics include the number of detection lines, relays, inputs/outputs, and optional modules for expansion.

Uploaded by

Adrian Oprisan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

• FROM 4 TO 12 DETECTION ZONES / FROM 1 to 2 EXTINGUISHING ZONES

• Standard EN54-2 / EN54-4 (EXTINGUISHING : EN 12094-1)

ALPHA 4/8/12, modular, compact and economic, is the adapted solution for small installations. It is
microprocessor controlled with SMD technology and with panel programming it is easy to use and install.
With its 4 zones in the basic version and its design, it is adapted for small installations.
Thanks to its optional modules, ALPHA 4/8/12 can be extended to 12 detection zones maximum (384 conventional
points) or 2 extinguishing channels maximum (1 extinguishing channel per extinguishing module). Thanks to its 2
slots ALPHA 4/8/12 can provide the following optimal solutions:
• 4 detection zones + 2 extinguishing channels
• 8 detection zones + 1 extinguishing channel
• 12 detection zones

Main characteristics

From 4 (128 points) to 12 (384 points) conventional


detection lines
Possibility to manage 2 extinguishing channels
maximum
32 detectors and/or manual call points per line
Monitored sounders line
Day/night mode
Programming by keyboard at access level 3
Easy management

Electrical specification
Mains supply voltage 230V ~ 50Hz
Operating voltage 27Vdc
wiring From 0,5 mm2 (500m max) to 2,5 mm ² (2500m max)
Batteries 2 x 12V/7,2AH
Maximum current supplied 1A
Mechanical characteristics
Dimensions (mm) / weight (without batteries) 300x370x118 (h x w x d) / 2Kg
IP rating 31
Climatic characteristics
Operating temperature 0°C to 50°C
Inputs/outputs
AR4D base detection module: 4 detection lines (128 points)
1 monitored programmable input : external power supply state monitoring (standard configuration), external sounders line activation,
external reset panel
1 monitored sounders line 24V/450mA
1 monitored external power supply output 24V/450mA
4 programmable open collector outputs: alarm, pre alarm,
disabled, test, system fault, power supply fault, fault 40V/0,1A
warning, evacuate, active, buzzer on, reset
1 Alarm NC/NO & 1 Fault NC/NO relay contact 30V/1A
Options
REP4R, R4P2, R7P2, & R12P2 4, 7, & 12 potential free contact relays boards 30V/1A
EX4A4 detection module 4 detection lines (32 det./line)

- Extinguishing actuators line (solenoid or pyroelectric),


24Vdc/1,2A
- Indicators/sounders line, 24Vdc/1A
DEAG extinguishing module - Manual extinguishing line
- Inhibition line
- Pressure contact line
- External power supply
REFERENCE DESCRIPTION
ALPHA 4/8/12 12 zones fire detection conventional panel equipped with 4 zones
OPTIONS & ACCESSORIES
EX4A4 4 zones expansion board
EX4A4 (EX) 4 zones expansion board for intrinsically safe products management
DEAG 1 zone extinguishing board
REP4R 4 programmable relays board (free voltage contact) 30V/0,3A
R4P2 4 relays board (free voltage contact) 30V/0,3A
R7P2 7 relays board (free voltage contact) 30V/0,3A
R12P2 12 relays board (free voltage contact) 30V/0,3A
TR-SDI Remote indicator panel with leds and function keys