0% found this document useful (0 votes)
161 views9 pages

Hollow Retaining Wall

This document provides details of a retaining wall analysis, including: - Dimensions and material properties of the retaining wall and surrounding soils - Calculations of forces on the wall from the retained soil and a surcharge load - Checks for stability against sliding and overturning using limit equilibrium methods The analysis found a factor of safety against sliding of 1.093, indicating the wall's resistance to sliding safely exceeds the horizontal sliding forces.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
161 views9 pages

Hollow Retaining Wall

This document provides details of a retaining wall analysis, including: - Dimensions and material properties of the retaining wall and surrounding soils - Calculations of forces on the wall from the retained soil and a surcharge load - Checks for stability against sliding and overturning using limit equilibrium methods The analysis found a factor of safety against sliding of 1.093, indicating the wall's resistance to sliding safely exceeds the horizontal sliding forces.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Project Job no.

Calcs for Start page no./Revision


1
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

RETAINING WALL ANALYSIS


In accordance with AS4678-2002 incorporating Amendment No.2 dated August 2008
Tedds calculation version 2.6.04

Retaining wall details


Stem type; Cantilever
Stem height; hstem = 2600 mm
Stem thickness; tstem = 450 mm
Angle to rear face of stem;  = 90 deg
Stem density; stem = 23.6 kN/m3
Toe length; ltoe = 950 mm
Heel length; lheel = 1250 mm
Base thickness; tbase = 350 mm
Base density; base = 23.6 kN/m3
Height of retained soil; hret = 1800 mm
Angle of soil surface;  = 0 deg
Depth of cover; dcover = 500 mm
Depth of excavation; dexc = 200 mm
Retained soil properties
Soil type; Medium dense well graded sand
Soil conditions; In situ
Moist density; mr = 21 kN/m3
Saturated density; sr = 23 kN/m3
Effective internal friction angle; 'r = 30 deg
External wall friction angle; r = 0 deg

Base soil properties


Soil type; Medium dense well graded sand
Soil conditions; In situ
Moist density; mb = 18 kN/m3
Effective cohesion; c'b = 0 kN/m2
Effective internal friction angle; 'b = 30 deg
External wall friction angle; b = 15 deg
External base friction angle; bb = 30 deg
Ultimate design bearing capacity; Pbearing = 200 kN/m2
Loading details
Live surcharge load; SurchargeQ = 10 kN/m2
Project Job no.

Calcs for Start page no./Revision


2
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

950 450 1250

15 kN/m2
300

5.8 kN/m2
1800
2600

2650
200
500
350

32.8 kN/m2

58.8 kN/m2 67.1 kN/m2

2650

Calculate retaining wall geometry


Base length; lbase = ltoe + tstem + lheel = 2650 mm
Moist soil height; hmoist = hsoil = 2300 mm
Length of surcharge load; lsur = lheel = 1250 mm
- Distance to vertical component; xsur_v = lbase - lheel / 2 = 2025 mm
Effective height of wall; heff = hbase + dcover + hret = 2650 mm
- Distance to horizontal component; xsur_h = heff / 2 = 1325 mm
Area of wall stem; Astem = hstem  tstem = 1.17 m2
- Distance to vertical component; xstem = ltoe + tstem / 2 = 1175 mm
Area of wall base; Abase = lbase  tbase = 0.927 m2
- Distance to vertical component; xbase = lbase / 2 = 1325 mm
Area of moist soil; Amoist = hmoist  lheel = 2.875 m2
- Distance to vertical component; xmoist_v = lbase - (hmoist  lheel2 / 2) / Amoist = 2025 mm
- Distance to horizontal component; xmoist_h = heff / 3 = 883 mm
Area of base soil; Apass = dcover  ltoe = 0.475 m2
- Distance to vertical component; xpass_v = lbase - (dcover  ltoe (lbase - ltoe / 2)) / Apass = 475 mm
- Distance to horizontal component; xpass_h = (dcover + hbase) / 3 = 283 mm
Area of excavated base soil; Aexc = hpass  ltoe = 0.285 m2
- Distance to vertical component; xexc_v = lbase - (hpass  ltoe (lbase - ltoe / 2)) / Aexc = 475 mm
- Distance to horizontal component; xexc_h = (hpass + hbase) / 3 = 217 mm
Material strength uncertainty factors for Soil - Table 5.1(A)
Uncertainty factor for friction of the retained soil; ur = 0.85
Project Job no.

Calcs for Start page no./Revision


3
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

Uncertainty factor for friction of the base soil; ub = 0.85


Uncertainty factor for cohesion of the base soil; uc = 0.7

Retained soil properties


Design effective internal friction angle; r = atan(ur  tan('r)) = 26.1 deg
Design external wall friction angle; r = atan(ur  tan(r)) = 0 deg

Base soil properties


Design effective internal friction angle; b = atan(ub  tan('b)) = 26.1 deg
Design cohesion; cb = uc  c'b = 0 kN/m2
Design external wall friction angle; b = atan(ub  tan(b)) = 12.8 deg
Design external base friction angle; bb = atan(ub  tan(bb)) = 26.1 deg

Using Coulomb theory


Active pressure coefficient; KA = sin( + r)2 / (sin()2  sin( - r)  [1 + [sin(r + r)  sin(r -
) / (sin( - r)  sin( + ))]]2) = 0.388
Passive pressure coefficient; KP = sin(90 - b)2  cos(b) / (sin(90 + b)  [1 - [sin(b + b) 
sin(b) / (sin(90 + b))]]2) = 3.696

Load combinations for stability limit states - Appendix J3


Load combination 1; 1.25  DeadC + 1.5  LiveC < 0.8  DeadR

Sliding check
Vertical forces on wall
Wall stem; Fstem = 0.8  Astem  stem = 22.1 kN/m
Wall base; Fbase = 0.8  Abase  base = 17.5 kN/m
Moist retained soil; Fmoist_v = 0.8  Amoist  mr = 48.3 kN/m
Base soil; Fexc_v = 0.8  Aexc  mb = 4.1 kN/m
Total; Ftotal_v = Fstem + Fbase + Fmoist_v + Fexc_v = 92 kN/m
Horizontal forces on wall
Surcharge load; Fsur_h = KA  1.5  SurchargeQ  heff = 15.4 kN/m
Moist retained soil; Fmoist_h = 1.25  KA  mr  heff2 / 2 = 35.8 kN/m
Total; Ftotal_h = Fmoist_h + Fsur_h = 51.2 kN/m
Check stability against sliding
Base soil resistance; Fexc_h = 0.8  KP  cos(b)  mb  (hpass + hbase)2 / 2 = 10.9 kN/m
Base friction; Ffriction = Ftotal_v  tan(bb) = 45.2 kN/m
Resistance to sliding; Frest = Fexc_h + Ffriction = 56 kN/m
Factor of safety; FoSsl = Frest / Ftotal_h = 1.093
PASS - Resistance to sliding is greater than sliding force
Overturning check
Vertical forces on wall
Wall stem; Fstem = 0.8  Astem  stem = 22.1 kN/m
Wall base; Fbase = 0.8  Abase  base = 17.5 kN/m
Moist retained soil; Fmoist_v = 0.8  Amoist  mr = 48.3 kN/m
Base soil; Fexc_v = 0.8  Aexc  mb = 4.1 kN/m
Total; Ftotal_v = Fstem + Fbase + Fmoist_v + Fexc_v = 92 kN/m
Horizontal forces on wall
Surcharge load; Fsur_h = KA  1.5  SurchargeQ  heff = 15.4 kN/m
Project Job no.

Calcs for Start page no./Revision


4
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

Moist retained soil; Fmoist_h = 1.25  KA  mr  heff2 / 2 = 35.8 kN/m


Base soil; Fexc_h = -0.8  KP  cos(b)  mb  (hpass + hbase)2 / 2 = -10.9 kN/m
Total; Ftotal_h = Fmoist_h + Fexc_h + Fsur_h = 40.4 kN/m
Overturning moments on wall
Surcharge load; Msur_OT = Fsur_h  xsur_h = 20.5 kNm/m
Moist retained soil; Mmoist_OT = Fmoist_h  xmoist_h = 31.6 kNm/m
Base soil; Mexc_OT = -Fexc_h  xexc_h = 2.4 kNm/m
Total; Mtotal_OT = Mmoist_OT + Mexc_OT + Msur_OT = 54.4 kNm/m
Restoring moments on wall
Wall stem; Mstem_R = Fstem  xstem = 26 kNm/m
Wall base; Mbase_R = Fbase  xbase = 23.2 kNm/m
Moist retained soil; Mmoist_R = Fmoist_v  xmoist_v = 97.8 kNm/m
Base soil; Mexc_R = Fexc_v  xexc_v = 1.9 kNm/m
Total; Mtotal_R = Mstem_R + Mbase_R + Mmoist_R + Mexc_R = 148.9 kNm/m
Check stability against overturning
Factor of safety; FoSot = Mtotal_R / Mtotal_OT = 2.736
PASS - Maximum restoring moment is greater than overturning moment
Bearing pressure check
Vertical forces on wall
Wall stem; Fstem = 1.25  Astem  stem = 34.5 kN/m
Wall base; Fbase = 1.25  Abase  base = 27.4 kN/m
Surcharge load; Fsur_v = 1.5  SurchargeQ  lheel = 18.8 kN/m
Moist retained soil; Fmoist_v = 1.25  Amoist  mr = 75.5 kN/m
Base soil; Fpass_v = 1.25  Apass  mb = 10.7 kN/m
Total; Ftotal_v = Fstem + Fbase + Fmoist_v + Fpass_v + Fsur_v = 166.8 kN/m
Horizontal forces on wall
Surcharge load; Fsur_h = KA  1.5  SurchargeQ  heff = 15.4 kN/m
Moist retained soil; Fmoist_h = 1.25  KA  mr  heff2 / 2 = 35.8 kN/m
Base soil; Fpass_h = -0.8  KP  cos(b)  mb  (dcover + hbase)2 / 2 = -18.6 kN/m
Total; Ftotal_h = max(Fmoist_h + Fpass_h + Fsur_h - Ftotal_v  tan(bb), 0 kN/m) = 0
kN/m
Moments on wall
Wall stem; Mstem = Fstem  xstem = 40.6 kNm/m
Wall base; Mbase = Fbase  xbase = 36.3 kNm/m
Surcharge load; Msur = Fsur_v  xsur_v - Fsur_h  xsur_h = 17.5 kNm/m
Moist retained soil; Mmoist = Fmoist_v  xmoist_v - Fmoist_h  xmoist_h = 121.2 kNm/m
Base soil; Mpass = Fpass_v  xpass_v - Fpass_h  xpass_h = 10.3 kNm/m
Total; Mtotal = Mstem + Mbase + Mmoist + Mpass + Msur = 225.9 kNm/m
Check bearing pressure
Distance to reaction; x = Mtotal / Ftotal_v = 1354 mm
Eccentricity of reaction; e = x - lbase / 2 = 29 mm
Loaded length of base; lload = lbase = 2650 mm
Bearing pressure at toe; qtoe = Ftotal_v / lbase  (1 - 6  e / lbase) = 58.8 kN/m2
Bearing pressure at heel; qheel = Ftotal_v / lbase  (1 + 6  e / lbase) = 67.1 kN/m2
Project Job no.

Calcs for Start page no./Revision


5
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

PASS - Allowable bearing pressure exceeds maximum applied bearing pressure

RETAINING WALL DESIGN


In accordance with AS3600-2009 incorporating Amendment No.1 dated November 2010 and AS3700-2011
incorporating Amendment No.1 dated September 2012
Tedds calculation version 2.6.04

Properties of concrete - Section 3.1


Characteristic compressive strength of concrete; f'c = 32 MPa
Characteristic flexural tensile strength of concrete - cl.3.1.1.3
f'ct.f = 0.6 MPa  [f'c / 1 MPa] = 3.394 MPa
Concrete shear strength - cl.8.2.7.1; fcv = min(f'c1/3  (1 MPa)2/3, 4 MPa) = 3.175 MPa
Calculate compressive stress factor - exp.8.1.3(1); 2 = max(0.67, min(1.0 - 0.003  f'c / 1 MPa, 0.85)) = 0.85
Calculate stress block factor - exp.8.1.3(2);  = max(0.67, min(1.05 - 0.007  f'c / 1 MPa, 0.85)) = 0.826

Reinforcement details
Characteristic yield strength of reinforcement; fsy = 500 MPa
Class of reinforcement; N
Exposure classification; A2
Shear strength of reinforcement - cl.8.8; fvs = 17.5 MPa
Cover to reinforcement
Top face of base; cbt = 50 mm
Bottom face of base; cbb = 75 mm
Masonry details
Hollow concrete units fully bedded with M3 class mortar, grouted at 400 mm centers
Characteristic unconfined compressive strength; f'uc = 5 MPa
Characteristic lateral modulus of rupture; f'ut = 0.8 MPa
Thickness of unit; tb = 450 mm
Length of unit; lb = 400 mm
Height of unit; hb = 190 mm
Joint thickness; tj = 10 mm
Face shell thickness; twf = 32 mm
End shell thickness; twe = 32 mm
Internal web thickness; twi = 32 mm
Depth of cavity; tc = tb - 2  twf = 386 mm
Length of cavity; lc = (lb - twi - 2  twe) / 2 = 152 mm
Characteristic compressive strength of grout; f'c,grout = 20 MPa
400 10

32
3 50
45 0

38 6

32

1 52 1 52
32

32

32
Project Job no.

Calcs for Start page no./Revision


6
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

Masonry design properties


Compressive strength - cl.3.3.2; f'm = 1.3  1.4  (f'uc  1 MPa) = 4.07 MPa
Tensile strength - cl.3.3.3; f'mt = 0 MPa
Shear strength - cl.8.8; f'vm = 0.35 MPa
Elastic moduli for short term loading - Table 3.4; Em = 1000  f'c = 32000 MPa
Elastic moduli for long term loading - Table 3.4; EL = 350  f'c = 11200 MPa

Load combinations for strength limit states - Appendix J2


Load combination no.1; 1.25  Dead + 1.5  Live
Load combination no.2; 0.8  Dead + 1.5  Live

Check stem design at base of stem


Depth of section; t = 450 mm
Masonry section properties
Total area; A = t - lc  tc / (lb + tj) = 306898 mm2/m
Bedded area - cl.4.5.4; Ab = 2  twf = 64000 mm2/m
Combined cross-sectional area - cl.4.5.5; Ac = Ab + tc  lc / (lb + tj) = 207102 mm2/m
Design cross-sectional area - cl.4.5.6; Ad = Ac = 207102 mm2/m
Grout area - cl.4.5.7; Ag = Ad - Ab = 143102 mm2/m
Design section modulus - cl.4.5.8; Zd = t2 / 6 + tc2  (lc / (lb + tj) - 1) / 6 = 18123590 mm3/m
Compressive strength of grout - cl.3.5; f'cg = min(f'c,grout, 1.3  f'uc) = 6.5 MPa

Structural design of reinforced masonry - Section 8


Factored bending moment combination 1; Md = 36.1 kNm/m
Design compressive force; Fd = 1.25  stem  hstem  A = 23.5 kN/m
Compressive stress on bed joints - cl.7.4.3.3; fd = min(Fd / Ad, 0.36 MPa) = 0.114 MPa
Reinforcement provided; 16 dia.bars @ 400 c/c
Area of reinforcement provided; Asr.prov =   sr2 / (4  ssr) = 503 mm2/m
Depth of reinforcement; d = 350 mm
Design area of reinforcement; Asd = min(0.29  1.3  f'm  d / fsy, Asr.prov) = 503 mm2/m
Design area of tension reinforcement; Ast = min(Asr.prov, 0.02  (lb + tj - lc) / (lb + tj)  d) = 503 mm2/m
Capacity reduction factor - Table 4.1;  = 0.75
Basic compresive capacity - exp.8.5; Fo =   [f'm  Ab + 1.2  (f'cg / 1.3 mm2/N)  Ag + fsy  Asr.prov] = 671.8
kN/m
Vertical slenderness coefficient; av = 2.5
Clear height of wall; H = hstem = 2600 mm
Thickness coefficient; kt = 1
Slenderness ratio - cl.7.3.4.3(4); Sr = av  H / (kt  t) = 14.444
Slenderness reduction factor; ks = min(1.18 - 0.03  Sr, 1.0) = 0.747
Compressive strength capacity - cl.8.5; ks  Fo = 501.6 kN/m
Fd / (ks  Fo) = 0.047
PASS - Compressive strength capacity exceeds design compressive force
Bending moment capacity - exp.8.6; Mc =   fsy  Asd  d  [1 - 0.6  fsy  Asd  (lb + tj) / (1.3  f'm  (lb + tj -
lc)  d)] = 57.4 kNm/m
Md / Mc = 0.628
PASS - Bending moment capacity exceeds design bending moment
Design shear force; Vd = 40.4 kN/m
Capacity reduction factor - Table 4.1;  = 0.75
Project Job no.

Calcs for Start page no./Revision


7
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

Shear capacity - exp.8.8; Vc =   min(f'vm  (lb + tj - lc) / (lb + tj)  d + fvs  Ast, 4  f'vm  (lb + tj - lc)
/ (lb + tj)  d) = 64.4 kN/m
Vd / Vc = 0.627
PASS - Shear strength capacity exceeds design shear force
Check base design at toe
Depth of section; h = 350 mm
Strength of section in bending - Section 8.1
Factored bending moment combination 1; M = 17.2 kNm/m
Depth to tension reinforcement; d = h - cbb - bb / 2 = 267 mm
Tension reinforcement provided; 16 dia.bars @ 200 c/c
Area of tension reinforcement provided; Abb.prov =   bb2 / (4  sbb) = 1005 mm2/m
Maximum reinforcement spacing - cl.9.1.1(b); smax = min(2  h, 300 mm) = 300 mm
PASS - Spacing of reinforcement is less than maximum
Neutral axis parameter; ku0 = Abb.prov  fsy / (2  f'c  d  ) = 0.084
ku0 < 0.36 - No compression reinforcement is required
Ultimate strength in bending; Mu0 = Abb.prov  fsy  d  (1 -   ku0 / 2) = 129.6 kNm/m
Uncracked section modulus; Z = h2 / 6 = 20416667 mm3/m
Minimum strength in bending - exp.8.1.6.1(1); Mu0_min = 1.2  Z  f'ct.f = 83.2 kNm/m
PASS - Ultimate strength in bending exceeds the minimum strength requirements
Capacity reduction factor - Table 2.2.2;  = max(0.6, min(1.19 - 13  ku0 / 12, 0.8)) = 0.8
Design strength in bending - cl.8.1.5; Mu0 =   Mu0 = 103.7 kNm/m
M / Mu0 = 0.166
PASS - Design strength in bending exceeds design bending moment
Strength of section in shear - Section 8.2
Design shear force; V = 36.8 kN/m
Beta factors - cl.8.2.7.1; 1 = max(1.1  (1.6 - d / 1000 mm), 0.8) = 1.466
2 = 1
3 = 1
Ultimate shear strength - exp.8.2.7.1; Vuc = 1  2  3  d  fcv  (Abb.prov / d)1/3 = 193.4 kN/m
Capacity reduction factor - Table 2.2.2;  = 0.7
Design strength in shear; Vuc =   Vuc = 135.4 kN/m
V / Vuc = 0.272
PASS - Design shear strength exceeds design shear force
Strength of section in bending - Section 8.1
Factored bending moment combination 1; M = 15.5 kNm/m
Depth to tension reinforcement; d = h - cbt - bt / 2 = 292 mm
Tension reinforcement provided; 16 dia.bars @ 200 c/c
Area of tension reinforcement provided; Abt.prov =   bt2 / (4  sbt) = 1005 mm2/m
Maximum reinforcement spacing - cl.9.1.1(b); smax = min(2  h, 300 mm) = 300 mm
PASS - Spacing of reinforcement is less than maximum
Neutral axis parameter; ku0 = Abt.prov  fsy / (2  f'c  d  ) = 0.077
ku0 < 0.36 - No compression reinforcement is required
Ultimate strength in bending; Mu0 = Abt.prov  fsy  d  (1 -   ku0 / 2) = 142.1 kNm/m
Uncracked section modulus; Z = h2 / 6 = 20416667 mm3/m
Minimum strength in bending - exp.8.1.6.1(1); Mu0_min = 1.2  Z  f'ct.f = 83.2 kNm/m
Project Job no.

Calcs for Start page no./Revision


8
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

PASS - Ultimate strength in bending exceeds the minimum strength requirements


Capacity reduction factor - Table 2.2.2;  = max(0.6, min(1.19 - 13  ku0 / 12, 0.8)) = 0.8
Design strength in bending - cl.8.1.5; Mu0 =   Mu0 = 113.7 kNm/m
M / Mu0 = 0.137
PASS - Design strength in bending exceeds design bending moment
Strength of section in shear - Section 8.2
Design shear force; V = 25.7 kN/m
Beta factors - cl.8.2.7.1; 1 = max(1.1  (1.6 - d / 1000 mm), 0.8) = 1.439
2 = 1
3 = 1
Ultimate shear strength - exp.8.2.7.1; Vuc = 1  2  3  d  fcv  (Abt.prov / d)1/3 = 201.4 kN/m
Capacity reduction factor - Table 2.2.2;  = 0.7
Design strength in shear; Vuc =   Vuc = 141 kN/m
V / Vuc = 0.182
PASS - Design shear strength exceeds design shear force
Transverse reinforcement parallel to base
Slab restrained in the secondary direction with moderate degree of control over cracking
Minimum area of reinforcement - cl.9.4.3.4; Abx.req = 0.0035  min(tbase / 2, 250 mm) = 613 mm2/m
Transverse reinforcement provided; 16 dia.bars @ 300 c/c
Area of transverse reinforcement provided; Abx.prov =   bx2 / (4  sbx) = 670 mm2/m
PASS - Area of reinforcement provided is greater than area of reinforcement required
350

16 dia.bars @ 250 c/c


horizontal reinforcement
parallel to face of stem

16 dia.bars @ 400 c/c

16 dia.bars @ 200 c/c


50

75
16 dia.bars @ 200 c/c

16 dia.bars @ 300 c/c


transverse reinforcement
in base
Project Job no.

Calcs for Start page no./Revision


9
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 23/03/2017

You might also like