SEP LEM012SD User Manual
SEP LEM012SD User Manual
1.2 Foreword
1.4 Specifications
1.6 Description
1.7 Dimensions
1.8 Installation
1.9 Operating
1.10 Troubleshooting
User manual
Warning
Means that failure to observe the instruction can result in death, serious injury or
considerable material damage.
Caution
Means hazard of electric shock and failure to take the necessary safety precautions will
result in death, serious injury or considerable material damage.
Qualified personnel
Commissioning and operation of the equipment (module, device) described in this
manual may only be performed by qualified personnel. Qualified personnel in the
sense of the safety information contained in this manual are persons who are
authorized to commission, start up, ground and label devices, systems and circuits
according to safety and Regulatory standards.
Exclusion of liability
We have checked the contents of this publication and every effort has been made to
ensure that the descriptions are as accurate as possible.
However, deviations from the description cannot be completely ruled out, so that no
liability can be accepted for any errors or omissions contained in the information
given. The data in this manual are checked regularly and the necessary corrections
are included in subsequent editions. We are grateful for any improvements that you
care to suggest.
Copyright
Copyright (c) 2011 SEP EUROPE All rights Reserved.
It is prohibited to pass on or copy this document or to use or disclose its contents
without our express permission. Any duplication is a violation of the law and subject
to criminal and civil penalties. All rights reserved, particularly in the event of a
patent award or utility model registration.
Registered trademarks
SEP EUROPE is registered trademark of Schotman Elektro BV.
1.2 Foreword
Thank you for purchasing the SEP LEM012SD DIN rail single phase two wire energy
meter. The SEP LEM012SD energy meter is the most advanced type electronic kWh
meter available at the market. With the SEP product range we have introduced a
large scale of energy meters on the market suitable for 110V AC to 400V AC (50 or
60Hz). Besides the normal energy meters we also developed our own pre-paid
meters with chip card, chip card re-loaders and a complete PC management control
system. For more information on other product please contact our sales department
at [email protected]
Although we produce the SEP LEM012SD meter according to IEC 62053-21 and our
quality inspection is very accurate there might always be a possibility that your
product shows a fault or failure for which we do apologize. Under normal conditions
your product should give you years of benefit and pleasure. In case there is problem
with the energy meter you should contact your dealer immediately. All energy
meters are sealed with a special seal. Once this seal is broken there is no possibility
to claim for warranty. Therefore NEVER open an energy meter or break the seal of
the energy meter. The warranty time is 6 months, after installation, and only valid
for construction faults.
1.4 Specifications:
1.6 Description
E C
D
3
A 21
20
SO
-
R
230 V,5(32)A,50H z
R A = 0 .5 Wh/ i m p
4 N
B
R L = 0. 5 W h/ im p
L
D
E C
1.7 Dimensions
Height 116. mm
Width 17.5 mm
Depth 59. Mm
Weight 0.12 Kg (net)
U i m a x = 2 7 V / li m a x = 2 7mA
R A = 0 .5 W h/im p (ti=8 0m s) S O
R L = 0.5 W h /im p
EN62053-21
Single phase 32A kWh meter
A DM1D V1.0
DMMetering
kWh
3
20
21
SO
-
230V,5( 32)A,50Hz
RA = 0 . 5 W h /im p
4
RL = 0 .5 Wh / im p
N
CAUTION
Turn off and lock out all power supplying the energy meter and the
equipment to which it is installed before working on it.
Always use a properly rated voltage sensing device to confirm that power is
off.
WARNING
Installation should be performed by qualified personnel familiar with
applicable codes and regulations.
Use isolated tools to install the meter.
Fuse or thermal cut-off or single-pole circuit breaker can’t be fitted on the
supply line and not the neutral line.
Case is sealed, failure to observe this instruction can result in damage for
meter.
20
3
+ 1
L
SO
N
6 4
21 -
1.9 Operating
Working indication
There is a white LED which has two colors (green and red) while burning in the front
panel of LEM012SD When the meter works normally, this LED will display green. When
meter is going wrong or no power supply, the LED will turn off.
Consumption indication
There is a white LED which has two colors (green and red) while burning in the front
panel of LEMO12SD When consumption happens, the LED will flash and display red.
The more quickly LED flash, the more consumption there is. For this LED, the flash rate
is 2000 impulses per kWh (0.5Wh/imp).
230V,5(32)A,50Hz
RA = 0.5 Wh/imp
RL = 0.5 Wh/imp
kWh
230V,5(32)A,50Hz 230V,5(32)A,50Hz
RA = 0.5 Wh/imp RA = 0.5 Wh/imp
RL = 0.5 Wh/imp RL = 0.5 Wh/imp
1 1
c) Meter version
When the meter re-switch on the power, it will display the meter version for 3
seconds, then display the other items. As follows indication SEP version is U1.00.
kWh
230V,5(32)A,50Hz
RA = 0.5 Wh/imp
RL = 0.5 Wh/imp
Pulse output
The LEM012SD DIN rail energy meter is equipped with an pulse output which is fully
separated from the inside circuit. That generates pulses in proportion to the measured
energy for remote reading purposes and accuracy testing. The pulse output is a polarity
dependant, passive transistor output requiring an external voltage source for correct
1.10 Troubleshooting
CAUTION
During repairing and maintenance, do not touch the meter connecting
clamps directly with your bare hands, with metal, blank wire or other
material as you will have the chance of an electricity shock and a possible
chance for health damage.
Turn off and lock out all power supplying the energy meter and the
equipment to which it is installed before opening the protection cover to
prevent the hazard of electric shock.
WARNING
Maintenance or repair should be performed by qualified personnel familiar
with applicable codes and regulations.
Use insulated tools to maintain or repair the meter.
Make sure the protection cover is in place after maintenance or repair.
Case is sealed, failure to observe this instruction can result in damage for
meter.
The register can’t Is there a power Check that the power supply
run. supply inside the indicator is burning.
meter?
LCD backlight can’t Is there a power Check that the power supply
lit. supply inside the indicator is burning.
meter?
www.sep-europe.nl
S.E.P. Europe
Weverstraat 4
9403 VJ Assen
Netherlands