TNA690A12
TRISECTOR QUAD-BAND 2x 790-960 MHz, 2x 1710-2170 MHz
Compact Antenna
Diameter 635 mm
External RET available
Electrical specifications* R1, R2 B1, B2
Frequency Range (MHz) 790—960 1710-2170
Polarization ±45º
Gain (dBi) 17 17,5
Electrical Tilt (continuously adjustable) 2—10
Horizontal Beamwidth (º), -3dB 65,2 56,9
Vertical Beamwidth (º), -3dB 7,2 6,5
Front to Back Ratio (dB)
>25 >25
180º±30º total power
Cross Polar Discrimination (dB)
>19 >23
Boresight
Sidelobe suppresssion (dB)
17
First sidelobe above horizon
First null fill (dB) Typ 20
Impedance (W) 50
VSWR < 1.5:1
B1 B2
Intraband isolation (dB) > 30
Interband isolation (dB) > 30
Intermodulation IM3 (dBc) < -150
R1 R2
Max power per input (W) 300
External RET AISG 2.0 / 3GPP Protocol
*All specifications are subject to change without notice. Refer to TELNET for the most current information.
Mechanical specifications
Input 24 x 7/16 female connectors
Position Bottom, 3 x 8 (7/16)
Dimensions (mm), H x Ø 2700 + 300 x 635
Weight (Kg) 120
Max wind speed (Km/h) 200
Azimuth (Full antenna / Per Sector) ± 50º / ± 0º
1 of 2 www.tenet‐ri.es V150505
TNA690A12
Materials
Radome Fiber glass + polyester
End Caps Stainless Steel
Screws and nuts Stainless Steel
Environmental and mechanical tests
IEC 60068-2-1: Cold IEC 60068-2-32: Free Fall Test
IEC 60068-2-2: Dry heat IEC 60068-2-56: Damp Heat Steady State
IEC 60068-2-6: Sine Vibration IEC 60068-2-64: Random Vibration
IEC 60068-2-14: Change of Temperature IEC 60529: IP Code Test
IEC 60068-2-18: Water (Handheld shower) IEC 60695-2-1/2: Resistance to fire
IEC 60068-2-27: Shock Test UNE-EN 60598-2-3: Resistance to wind
IEC 60068-2-29: Bump Test Particular Specification: Resistance to ice
IEC 60068-2-30: Damp Heat Cyclic
Environmental RET test
Temperature –33º C a 70º C
Humidity 50º C, 98HR
Saline Fog IEC68-2-52, severity 2
IP specification IP66, IEC 60529 (Feb 2001)
2 of 2 www.tenet‐ri.es V150505