Plumbing Symbols

This document contains symbols and descriptions for fire protection systems. It includes symbols for items like smoke, fire ratings of 1/2 hour or 1 hour, smoke barriers, hydrants, fire alarms, sprinklers, and elevators or stairs in combustible or fire rated shafts. Over 40 different symbols are described.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
173 views6 pages

Plumbing Symbols

This document contains symbols and descriptions for fire protection systems. It includes symbols for items like smoke, fire ratings of 1/2 hour or 1 hour, smoke barriers, hydrants, fire alarms, sprinklers, and elevators or stairs in combustible or fire rated shafts. Over 40 different symbols are described.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Supply lino

Compruslon nut

Closet bolt slot

Closet bend
FIRE PROTECTION s y M BO Ls (NFPA 170) APPENDIX D -
FlLE
"'ME SYMBOL DESCRIPTION
FILE
"'UE SYMBOL DESCRIPTION �'!Ii SYMBOL DESCRIPTION

F001 s SMOKE SYMBOL F021



'I"
PUBLIC ARE H-.ORANT - FOJB
O:o2 CARSON DIOXIDE

..•
1'110 HOSE OUT1.£T
'
-I
f002 1/2 HOUR SYIIBOL
PUBLIC nRE HYDRANT - 1WO FOJ9 .........i REOLICER
F022
HOSE OIJT1..£T & PIJMPER
H

•"'
fOOJ J/< HOUR SYIIBOL f040 AL4RM GONG
� CONNECTION

FOO•
•-s- 1 HOUR Sl'MBOL

SMOKE BARRIER
F023

'l'
W.U. H-.olWIT - TWO HOSE
OVTlET f0+1 I�<
--
Wi\TER MOTOR "1../.RM GONG

NEW WALL OR FIRE


RESIS11VE FLOOR OR ROOF

<Iii
PRWATE HOUSED HYOR.4NT -
-+-
F024 TWO HOSE ovn.rr ---- EXISTING W.U.

v
1/2 HOUR f'IRC RATED
iiiiiiiiiiii WOOD JOIS!m FLOOR
s -15- 1/2 HOUR FIRE PATED/ FOZS
ARE DEPARTMENT - TWO HOSE OR ROOFS
0
m SMOKE BARRIER OUT1.£T, FREE Sl,WOINC
-- OlHER FLOORS OR ROOFS

,.Y, --
NOTE CONSfRVCTION
-+-

..
� 3/• HOUR FIRE RATED FIRE DEPARTMENT - TWO HOS£
w F026 Oun.ET OPENING IN YAALJ.
ffl -.s
.r.
3/4 HOUR FIRE RATED/ __/_
iE
':;1<1
SMOKE BARRIER
F027 FIRE DEPARTMENT - ONE HOSE
OUT1.£T
W!B ffifi �00.11,J�sru.
��
-+- 1 HOUR flRE RATED J_ EXISTING W.U.
r_,
�"
.... � 1 HOUR FIRE R,\TBJ/ f02B f1RE PUMP WITH ORt\lES

;�
ELEVATOR IN COMBUSTABLE
SMOKE BARRIER ,E SIWT
ao
�_J
w .. 2 HOUR FIRE R.-.TED F02.9 FREEST..WOING TEST HEIDER
�Q
flf\lATOR IN NON-
�f �

......
COMBIJSTAEl.E SH-.FT
o:.!. -++5- 2 HOIJR ARE RATED/
SMOKE BMRIER r-,
FOJO WAlL - MOUNT'fD lEST HEAOER
fl� � IE OPEN HOISTWAY

fl,
�--'
s 3 HOUR FIRE RATEi>
s ....s- l HOUR FIRE RATED/ f'O�l S�EEN/STRAINfR l@jjjil £SCALATOR

"�
.....
SMOKE BARRIER
[Jiii] STAIR IN COMBUSTABLE
!il
� •••• ,t. HOUR FIRE RATED

,t. HOUR f!RE RATED/


FO:l2 - -. CATI-,111)
FCP FIRE ALARU OONTROL PAHB.
':;
z [HJ
SHAFT

STAl R IN ARE RATED


SHAFT
• •• •S SMOKE BAARIER
0
fSt. FIRE SYSTEM ANNUNC�TOR
"'"wz IIlIDlDIID STAIRS IN OPEN Slittn

..
nR FIRE PURM lRANSPONQER OR
FOOS
0 RIS�
TRANSMITTER
0:
IZ
w
ril
L::.J
SKYLIGHT
ESR ELEVATOR STATUS/REC.OU
F006 ,-1>4-,> W.L\IES (G�ERAL)
� FIRE AL.ARM COMMUNICATOR
0:
ii! f++i PARAPET

VAL� IN Prr FLOO%COUNC OR


F007 � HCP HALON CON!ROL P,WEL ROOF CEIUNC ASSEMBLY

F008 ,__iJ.,_, POST-INDICATOR V;J.\£ tM CONTROL PANEL fefi FLOOR ON GROUND


HEATIN� VENTILATION.
.....�
NR-CONDmON!NG, EXHAUST A>-., TRUSS ROOF

m
F008 KEY OPERATATED VALVES STAIRWEil_ PRfSSURIZATION,
O� SIMILAR EQUIPMENT.
OS & Y VALVE �U151DE BOILER

e
F010 SCREN ltNO YO (RISING
SlEU)
� IUUM!�TED EXIT S!G.N. SINGt.£
F011 ,....� INOICATlHC 8UTTEl'FLY \,71,LVE
fOJ,J
"'CE
CHIMNEY

/'-'*"'
IUUMINATED DJT SIGN. DOUBLE
NONINDICATING "'1.\/E
FOJ4 � "'CE FIRE ESC.<PE
F012
(NO,,RISIN�-STE• VALVE:) �
F01J � CM£CK VAL\1£
ro:,e
Ji\. EMEACENC'I LICHT, BATTEl!Y
POWERED c=> TANK, ABOVE GROUHO,
MORIZ.

--
ft)1+ � BACKFLOW PRE.VENTER -
-- I QOUBLE CHECK lYPE
FO:l<l
Jil>
COMBINED Bt.TTERY- POfERED
EMERGENCY LIGHT AMO
IUUMl�TED DlT SIGN
0....,
,----
T;.NK, A80V£ GROUND. 'vERT

n, '---·
F015 � Bt.CKfl...C1# PRCVENTt:R - TANK! BELO'� GROUND,
HORI ,

-
- REDUCED PRESSURE ZONE
FOl7
(Rl'Z) TYPE

�...,, HL - I-UrlLON PUBLIC WRER �N


ro,s
,___....,,
PRESSURE REGULATING
= PRIY.AlE WAlER IMJN

-�.
VAL� DC - DRY CHEMIC"4..
,017 PRESSURE RELIEF VAM FO - FOAM --- UNOER WATER Ml.IN
BUILDING
ec -
,.....;i,..,. WET CHEMic-!. SUCllON PIPE

....
FOl.8 FlOAT VALVE
p - PUU SfA11014
lHRUST BLOCII
MS)-, METER CA - CLEm ..CENT
� � - �'ATER MIST
,020 PRIVAlE HYDRANT, ONE
HOSE OUTLEr Ol - DEWGE SPRINKLER

APPENDIX D-1 REVISION 3, MTE 8-16-200+