Electrical Equipment Specs Guide

This document summarizes and compares the specifications of 4 PMCB models. Some key specs included are: - Dimensions and materials of switching and control boxes ranging from 650x500x750mm to 1220x1280x1600mm. - Rated voltages of 24kV, currents of 630A and 1250A, and frequency of 50/60Hz. - Vacuum circuit breakers with insulation of 125kV and mechanical and electrical test classes. - Protection features including overcurrent, overload, breaker failure, directional, autoreclose, voltage/frequency protections. - Current and potential transformers, kWh meters, batteries, chargers, and 100

Uploaded by

Alfia Rochman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
180 views1 page

Electrical Equipment Specs Guide

This document summarizes and compares the specifications of 4 PMCB models. Some key specs included are: - Dimensions and materials of switching and control boxes ranging from 650x500x750mm to 1220x1280x1600mm. - Rated voltages of 24kV, currents of 630A and 1250A, and frequency of 50/60Hz. - Vacuum circuit breakers with insulation of 125kV and mechanical and electrical test classes. - Protection features including overcurrent, overload, breaker failure, directional, autoreclose, voltage/frequency protections. - Current and potential transformers, kWh meters, batteries, chargers, and 100

Uploaded by

Alfia Rochman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

RATING DAN SPESIFIKASI PRODUK PMCB

Model Name PMCB 1.0 PMCB 2.0 PMCB 3.0 PMCB 4.0
Type Outdoor
Material SPCC (mm) 2
Box Switching
Dimension (P x L x T) (mm) 1220 x 1280 x 1600
Finishing Coating Powder
Type Outdoor
Material SPCC (mm) 2
Box Control
Dimension (P x L x T) (mm) 650 x 500 x 750
Finishing Coating Powder
Standard IEC 62271-100 (2012)
Rated voltage (kV) 24
Rated current (A) 630 1250 630 1250 630 1250 630 1250
Rated frequency (Hz) 50/60
Rated short time withstand current (kA) 16
Vaccum Circuit Breaker Insulation level Lighting impulse withstand voltage (kV) 125
Mechanical M2 (10000 times)
Type test class
Electrical E2 (List3)
Operating mechanism Motor spring type
Control voltage Closing coil DC 24V
Opening coil DC 24V
Type Indoor
Primer (A) 10-600 10-1000 10-600 10-1000 10-600 10-1000 10-600 10-1000
Ratio
Sekunder (A) 5-5
Current Transformer
Metering 0,2S
Class
Protection 5P10
Burden (VA) 10
Type x Indoor
Primer (V) x 20000√3
Ratio
Sekunder (V) x 100√3
Voltage Transformer
Metering x 0,2
Class
Protection x 3P-6P
Burden (VA) x 30
Connection x x 3P4W
kWh Meter
Class x x 0,5S
Phase overcurrent (50/51) √
Earth fault overcurrent (50N/51N) √
Negative squence overcurrent (46) √
Thermal overload (49) √
Breaker failure (50BF) √
Protection Relay Feature
Directional overcurrent (67) x √ x √
Autoreclose (79) √ √ x √
U/O voltage (27/59) x √ x √
U/O frekuensi (81U/81O) x √ x √
Lockout / latching (86) √
Ingress Protection IP34
Capacity (Ah) 28
Battery Rated voltage (V) 12
Total (unit) 2
Input voltage (V AC) 170 - 270
Output voltage (V DC) 24 - 27,4
Floating √
Battery Charger
Equalizing √
Feature
Boost charge √
Protection √
Capacity (W) 100
Heater
Rated voltage (V) 220

Keterangan:
1. X = tidak tersedia
2. √ = tersedia