0% found this document useful (0 votes)
211 views6 pages

XPSMP11123P Safety Controller Overview

This document provides product information for the XPS-MP safety module. The XPS-MP module has 2 independent safety functions, operates on 24V DC power, and can achieve safety levels up to SIL 3 and PL e. It has various configurable functions for monitoring devices like emergency stops, light curtains, and safety mats. The module has relay and solid state outputs and is intended for use in safety automation applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
211 views6 pages

XPSMP11123P Safety Controller Overview

This document provides product information for the XPS-MP safety module. The XPS-MP module has 2 independent safety functions, operates on 24V DC power, and can achieve safety levels up to SIL 3 and PL e. It has various configurable functions for monitoring devices like emergency stops, light curtains, and safety mats. The module has relay and solid state outputs and is intended for use in safety automation applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Product data sheet XPSMP11123P

Characteristics module XPS-MP - 2 independent functions - 24 V


DC

Main

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Range of product Preventa Safety automation
Product or component type Safety controller with pre-defined function
Safety module name XPSMP
Safety module application 2 independent functions
Safety use category Category 4 maximum conforming to EN/IEC 60954-1
Type of start Automatic or unmonitored (configuration 1)
Automatic or unmonitored (configuration 10)
Automatic or unmonitored (configuration 11)
Automatic or unmonitored (configuration 14)
Automatic or unmonitored (configuration 3)
Automatic or unmonitored (configuration 5)
Automatic or unmonitored (configuration 7)
Monitored (configuration 12)
Monitored (configuration 13)
Monitored (configuration 15)
Monitored (configuration 2)
Monitored (configuration 4)
Monitored (configuration 6)
Monitored (configuration 8)
Monitored (configuration 9)
Checks Configuration (configuration 10)
Configuration (configuration 13)
Configuration (configuration 3)
Configuration (configuration 4)
Configuration (configuration 5)
Configuration (configuration 6)
Configuration (configuration 9)
Standards DIN V VDE 801 + A1
EN/IEC 60204-1
EN/IEC 60947-1 + A11
EN/IEC 60947-5-1
Product certifications BIA
CSA
UL
[Us] rated supply voltage 24 V DC (- 20...20 %)
Connections - terminals Captive screw clamp terminals, removable terminal block: 0.2...1 mm², 2 wires solid without cable
end
Captive screw clamp terminals, removable terminal block: 0.2...1.5 mm², 2 wires flexible without
cable end
Captive screw clamp terminals, removable terminal block: 0.2...2.5 mm², 1 wire flexible without cable
end
Jul 22, 2019
1
Captive screw clamp terminals, removable terminal block: 0.2...2.5 mm², 1 wire solid without cable
end
Captive screw clamp terminals, removable terminal block: 0.25...1 mm², 2 wires flexible with cable
end, without bezel
Captive screw clamp terminals, removable terminal block: 0.25...2.5 mm², 1 wire flexible with cable
end, with bezel
Captive screw clamp terminals, removable terminal block: 0.25...2.5 mm², 1 wire flexible with cable
end, without bezel
Captive screw clamp terminals, removable terminal block: 0.5...1.5 mm², 2 wires flexible with cable
end, with double bezel
Safety level Can reach SIL 3 conforming to EN/IEC 62061
Can reach PL e/category 4 conforming to EN/ISO 13849-1

Complementary
Function of module Configuration 0: functions disabled (factory setting)
Configuration 1: emergency stop monitoring 1-channel wiring, category 2
Configuration 10: enabling grip switch monitoring (3-position switch), category 4
Configuration 11: sensing mat and edges monitoring, category 3
Configuration 12: sensing mat and edges monitoring, category 3
Configuration 13: relay output safety light curtain monitoring, category 4
Configuration 14: coded magnetic switch monitoring, category 4
Configuration 15: coded magnetic switch monitoring, category 4
Configuration 2: emergency stop monitoring 1-channel wiring, category 2
Configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
Configuration 9: guard monitoring for injection presses and blowing machines, category 4
Synchronisation time between inputs 0.5 s (configuration 13)
1.5 s (configuration 14)
1.5 s (configuration 15)
1.5 s (configuration 5)
1.5 s (configuration 6)
1.5 s (configuration 9)
Unlimited (configuration 3)
Unlimited (configuration 4)
Unlimited (configuration 7)
Unlimited (configuration 8)
Power consumption in W <= 5 W
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V
Line resistance 100 Ohm 2000 m
Number of safety circuits 3 NO relays per function (6 NO total), volt-free
Number of additional circuits 3 solid state outputs
Breaking capacity C300 : holding 180 VA AC-15 for relay output
C300 : inrush 1800 VA AC-15 for relay output
Breaking capacity 20 mA / 24 V for static output circuit
1.5 A / 24 V - L/R = 50 ms, DC-13 for relay output
Output thermal current 2 A for 1 output and 4 A for the other 2 outputs for relay
3.3 A for all 3 outputs relay simultaneously
6 A for 1 output and 2 A for the other 2 outputs for relay
[Ith] conventional free air thermal <= 20 A
current
Associated fuse rating 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Response time on input open < 30 ms
[Ui] rated insulation voltage 300 V, degree of pollution 2 conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Local signalling 12 LEDs
Mounting support 35 mm symmetrical DIN rail
Depth 114 mm

2
Height 99 mm
Width 45 mm
Product weight 0.32 kg

Environment
IP degree of protection IP20 (terminals)
IP40 (enclosure)
Ambient air temperature for operation -10...55 °C
Ambient air temperature for storage -25...85 °C

Contractual warranty
Warranty period 18 months

3
Product data sheet XPSMP11123P
Dimensions Drawings

Dimensions

4
Product data sheet XPSMP11123P
Connections and Schema

Wiring Diagrams

Refer to the Instruction Sheet


To download the instruction sheet, follow below procedure:

1 Click on Download & Documents.


2 Click on Instruction sheet.

5
Product data sheet XPSMP11123P
Technical Description

Safety Functions

● Emergency stop monitoring, 1 channel wiring:


○ 1 channel Emergency stop, automatic or unmonitored start.
○ 1 channel Emergency stop, monitored start.
● Emergency stop monitoring, 2 channel wiring:
○ 2 channel Emergency stop, automatic or unmonitored start.
○ 2 channel Emergency stop, monitored start.

● Coded magnetic switch monitoring:


○ Automatic or unmonitored start, synchronization time = 1,5 s.
○ Monitored start, synchronization time = 1,5 s.

● Guard monitoring with start test:


○ Locking of guard with start test, automatic or unmonitored start.
○ Locking of guard with start test, monitored start.
● Guard monitoring with start test and synchronization time = 1,5 ms:
○ Locking of guard with start test, automatic or unmonitored start.
○ Locking of guard with start test, monitored start.
● Guard monitoring for injection press or blowing machine.

● Enabling switch monitoring, safety mat monitoring:


○ Enabling switch monitoring, with or without start-up preparation.
○ Safety mat monitoring, automatic or unmonitored start.

● Sensing mat monitoring, monitored start.

● Light curtain monitoring, monitored start, synchronization time = 0,5 s.