SM DIN 24x48 / 72x72 / 96x48
series Tachometer & Line speed meter
* Multifunction meter
Tachometer、Line speed meter & Duty meter
* Pulses per revolution settable
* Sampling time auto tuning
* Decimal point settable
* Limit of alarm settable
* Transmitter of multifunction meter is optional
*
◆ General data / 共同規格
Outline 外型 24 x 48 96 x 48 72 x 72
Model 型號 SM-10 SM-20 SM-20S SM-30 SM-30S
Transmitter Non Non 4~20mA Non 4~20mA
Alarm output 警報輸出 Relay Relay Non Relay Non
Output control 輸出控制 Hi / Lo Hi / Lo Non Hi / Lo Non
Digits 位數 4 digits
Power supply 工作電壓 90 ~ 265 VAC 50/60 Hz
Current consumption 耗電流 5VA max.
DC output 直流輸出 12 V / 100 mA max.
Input method 輸入方式 NPN
Response time 應答時間 Ton = 0.1 ms ~ 99.9 ms settable
Pulses per revolution(PPR) 1~999 PPR settable
Diameter 1 ~ 999mm settable (Line speed meter available only)
Memory method 記憶方式 EEPROM
ESD strength 耐靜電 Over 8 KV
Dielectric strength 電介強度 Over 2.5 KV / 1 min., Between power and each other terminal
Isolation strength 絕緣強度 Over 100 MΩ / 500 VDC, Between power and each other terminal
Operating Circums. 工作環竟 ﹣20 ℃ ~ ﹢80℃;35% ~ 85% RH
◆ Outline dimension / 外形尺寸圖
Fixed Hole : 45.0 x 23.0 Fixed Hole : 45.0 x 91.0 Fixed Hole : 68.0 x68.0
SM-10 Panal Thickness : 1.0 ~ 8.0 SM-20□ Panal Thickness : 1.0 ~ 8.0
Unit : mm
SM-30□ Panal Thickness : 1.0 ~ 8.0
Unit : mm
Unit : mm
FOTEK SM-10
RPM
SET F
FOTEK Tachemeter & Line Speed Meter SM-20 SET TACHOMETER
&
LINE SPEED METER
FOTEK SM-30
FOTEK 31
SM-□□ Tachometer & Line speed meter
Series
◆ Data setting / 參數設定
Status / 狀態 Symb./ 顯示符號 Description / 說明
Running status 1> Running status / 運轉狀態
100.0
運轉狀態
Press SET key 3 sec
1>「Lck = 0」
:Unlock / 可設定
Setting of lock Lck.0 2>「Lck =1」:All lock / 鎖定
鎖住設定
Press SET key
1>「PPR」:Pulses per revolution
Setting of PPR P.001 2> Range:1 ~ 999
每轉信號數設定
Press SET key
1>「d..100」:Diameter of roller=100 mm(Range=1~999mm)
Setting of diameter d.100 2>Disappeared at tachometer mode
輪軸直徑設定
Press SET key
1> Range :0 ~ 9999
Setting of Limit 1000
2> Range:0 ~ 9999
警報值設定
Press SET key
1>「C.0」:PV>「Limit value」→ Relay ON
Setting of alarm status C.0
2>「C.1」:PV<「Limit value」→ Relay ON
警報輸出狀態設定
Press SET key
1>「t」:0 ~ 999s
Power on delay time t.0 2>Power on alarm output delay time
送電延遲時間
Press SET key
L.000 1>Distance of measuring:Unit = 1 Meter
Setting of distance 2>Passing time T(sec) = 「L」/ Line speed
通過行程設定 3>「L」appeared at 「nod.5」only
Press SET key
◆Function setting / 功能設定
Status / 狀態 Symb / 顯示符號 Description / 說明
1> Running status / 運轉狀態
Running status 100.0
運轉狀態 2> SM-10 /SM-30: ▼ key;SM-20:DN key
Press DN key 3 sec
1>「nod.0」= RPM ; 2>「nod.1」= RPS
Selection of meter 3>「nod.2」= RPH ; 4>「nod.3」= M / min.
轉速表或線速表選擇 nod.0 5>「nod.4」= Yd/min; 6>「nod.5」= T sec
Press SET key
1> Response time(r):Response frequency =(500 / r)Hz
Setting of response time
反應時間設定
r.00.1 2> Range:0.1 ~ 99.9 ms
Press SET key 1>「dP.A」= Decimal point auto shift
Setting of decimal point 2>「dP.n」= Without decimal point
dP.A 3>「dP.1」= One decimal point
小數點選擇
Press SET key
32 FOTEK
SM-□□S Tachometer & Line speed meter with resender
Series
◆ Data setting / 參數設定
Status / 狀態 Symb./ 顯示符號 Description / 說明
Running status 1> Running status / 運轉狀態
100.0
運轉狀態
Press SET key 3 sec
1>「Lck = 0」
:Unlock / 可設定
Setting of lock Lck.0 2>「Lck =1」:All lock / 鎖定
鎖住設定
Press SET key
1>「PPR」 :Pulses per revolution
Setting of PPR P.001 2> Range:1 ~ 999
每轉信號數設定
Press SET key
1>Diameter of roller:1 ~ 999 mm
Setting of diameter d.100 2>Disappeared at tachometer mode
輪軸直徑設定
Press SET key
3> Range of transmitter:0 ~ 9999
Limit of transmitter 1000 「0 ~ 1000」is transmittered to「4 ~ 20 mA」
傳送範圍設定
4> Range:0 ~ 9999
Press SET key
Setting of distance L.00.0 1>Distance of measuring:Unit = m
通過時間行程設定 2>Passing time T(sec) = 「L」/ Line speed
Press SET key 3SEC
3>「L」appeared at 「nod.5」only
◆ Function setting / 功能設定
Status / 狀態 Symb / 顯示符號 Description / 說明
1> Running status / 運轉狀態
Running status 100.0
運轉狀態
Press DN key 3 sec
Selection of meter 1>「nod.0」= RPM ; 2>「nod.1」= RPS
轉速表或線速表選擇 nod.0 3>「nod.2」= RPH ; 4>「nod.3」= M / min.
5>「nod.4」= Yd/min; 6>「nod.5」= T sec
Press SET key
Setting of response time 1> Response time(r):Response frequency =(500 / r)Hz
反應時間設定
r.00.1
2> Range:0.1 ~ 99.9 ms
Press SET key
1>「dP.A」= Decimal point auto shift
Setting of decimal point
dP.A 2>「dP.n」= Without decimal point
小數點選擇
3>「dP.1」= One decimal point
Press SET key
Offset of 4 mA 1> Range:-99 ~ 999
□.000 2> Offset of transmitter (4 mA)
4 mA 偏差值設定
Press SET key 3 sec
1> Range:-99 ~ 999
Offset of 20 mA □ .000
20 mA 偏差值設定 2> Offset of transmitter (20 mA)
Press SET key
FOTEK 33
DIN 24x48 / 72x72 / 96x48 SM
Tachometer & Line speed meter series
◆ Connection diagram / 接線圖
SM-10 SM-20 SM-30
50mA
Sensor
max
100 m A
10 9 8 7 6 m ax
0V IN +12V
Limit Output PowerSupply
9 8 7 6 5 4 3 2 1 8 9 10 11 12 13 14
1 2 V IN 1 IN 2 0V RST
GATE
Output Power RST1
N M a n u a l R e se t
C 2 .5 K H z A
5 4 3 2 1 110V R
30Hz B A u to R e se t
NO NC C
~ 60mA/12V
220V L im it O u tp u t P O W E R
50/60Hz
3A/250VAC 90~265VAC Max 7 6 5 4 3 2 1
C
50/60Hz ~
NC NO 220 VAC
110 VAC
380 VAC
◆ Selection of meter / 轉速表或線速表選擇
nod Type of meter Method of measuring
「0」 Tachometer (RPM) 「RPM」:Revolutions per minute 每分鐘幾轉
「1」 Tachometer (RPS) 「RPS」 :Revolutions per second 每秒幾轉
「2」 Tachometer (RPH) 「RPH」 :Revolutions per hour 每小時幾轉
「3」 Line speed meter (M/min.) 「M/min.」:Meter per minute.
「4」 Line speed meter (Yd/min.) 「Yd/min.」:Meter per minute.
「5」 Duty meter (SEC) 「SEC」:Time of duty
◆ Alarm output
Mode 「C.0」 「C.1」
Limit Limit
Power on Power on
Alarm Alarm
t
◆ Duty meter:To measure the passing time(T)from 〝A〞to B〞
Passing time: 「T」(sec) Object
「T」 (sec) = 「L」/ Line speed □ → □ → □ → □
「d」mm = Diameter of rolle ○ ○
「L」m = Distance from 〝A〞to B〞 L (m) Roller
A B
34 FOTEK