0% found this document useful (0 votes)
458 views1 page

Radiographic Examination Report: Date

This document is a radiographic examination report for a client project. It provides details of the radiographic testing technique used such as radiation source, sensitivity and density requirements, film size and processing. It documents the item/weld numbers tested, areas of interest, and results such as cracks, incomplete fusion or penetration that were interpreted from the radiographs. Inspectors, approvers and witnesses are named with signatures.

Uploaded by

Abhishek Sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
458 views1 page

Radiographic Examination Report: Date

This document is a radiographic examination report for a client project. It provides details of the radiographic testing technique used such as radiation source, sensitivity and density requirements, film size and processing. It documents the item/weld numbers tested, areas of interest, and results such as cracks, incomplete fusion or penetration that were interpreted from the radiographs. Inspectors, approvers and witnesses are named with signatures.

Uploaded by

Abhishek Sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

EACS DATE:

RADIOGRAPHIC Report No :
Request No :
EXAMINATION REPORT
Page No. :

Client : Project No : Location :


Order / Drg No: Mark / Item No: Material :
Reference procedure Specification : Surface condition:
Acceptance Criteria : Surface Temp: Thickness:
Technique Description Equipment and Material

Min . (SOD) : Max. (OFD) : Radiation Source : Ir.192 X Ray

Sensitivity Requirement : Density Requirement: Source Strength (Energy) : Ci Kv

No. of Films / Cassette : Film Size : Source Size / Focal Spot : Film Brand and Designation:

Film Processing : Manual Automatic


IQI Location : IQI Type : Wire Hole
Lead Screens : Front Back None
Exposure / Viewing Technique : SWSI DWSI DWDI

Order No. Item/Mark Weld No Welder No Area of Interpretation Result Remarks


/Drg. No interest

Note: CR: Crack IF: Incomplete Fusion IP: Incomplete Penetration SOD : Source to Object Distance
P: Porosity CP : Cluster Porosity SL: Slag Inclusion OFD : Source side of Object to Film Distance
TI : Tungsten Inclusion HB: Hollow Bead DWSI : Double Wall Single Image
UC : Undercut EP: Excess Penetration DWDI : Double Wall Double Image
CON : Concavity SWSI : Single Wall Single Image

NDT Inspector Approved by Witnessed by

Name

Signature

Level

Date

You might also like