MANUFACTURERS OF TECHNICAL
INDUSTRIAL COATINGS DATA SHEET
14 – SERIES
F/D ALKYD ENAMELS
DESCRIPTION: PICCO 14 – Series F/D Enamels are very fast dry enamels sometimes
referred to as oilfield or shop coat enamels. The PICCO 14 – Series F/D Enamels are
formulated to provide the gloss and general appearance of standard enamels while
providing cost reductions through faster handling and output of coated products. Dry
times can be further modified to compete with nitro-cellulose and Acrylic Lacquers.
They provide good color and gloss retention on exterior exposure.
TYPICAL USES INCLUDE
Storage Tanks and Piping Structural Steel Cranes and Lift Equipment
Machinery and Equipment Railroads Buildings, Trucks and Trailers
TYPICAL PHYSICAL PROPERTIES:
COLOR: All standard colors RECOMMENDED D.F.T.: 1.5 –2 mils
COMPONENTS: One DRY TIME: @ 77º F., 55% R.H.
GLOSS: Full To Touch: 10 - 15 Minutes
To Handle: 2 Hours
MIXING RATIO (BY VOL.): N/A To Recoat: 1-2 Hours
W.T./GALLON: 10.0 lbs THINNING: Brush: T-43 (not normally
recommended)
POT LIFE: N/A Spray: T-42 or Xylene
VISCOSITY AT 77º F: 68 KU APPLICATION METHODS:
Spray, Dip, Electrostatic Spray
SHELF LIFE: 3 Years
FILM THICKNESS:
SOLIDS BY WEIGHT: 54%
Wet: 4.5 mils
TEMP. RESISTANCE: 225º F Dry: 1.5 mils
SOLIDS BY VOLUME: 36% APPLICATION EQUIPMENT:
CHEM. RESISTANCE: Moderate CONVENTIONAL: DeVilbiss 510 Gun
E Tip + Needle, 704 Air Gap
THEORETICAL COVERAGE:
560 ft2/gal @ 1 mil dft AIRLESS: Graco 30:1 Pump, 613 Tip
or equivalent
FLASH POINT: 75º F, TCC
CLEANING OF EQUIPMENT:
V.O.C.: 4.6 lbs/gal T-42 or Xylene
14-Series Fast Dry Industrial Enamel
Page 1 of 2
September 2008
PACKAGING:
1 Gallon Cans 5 Gallon Pails 55 Gallon Drums
APPLICATION CONDITIONS:
Surface should be dry, above 40º F and at least 5º F above the dew point.
SURFACE PREPARATION:
Remove all grease, oil, dirt, dust or other contaminants
NORMAL SERVICE: SSPC–SP2 and 3 Hand and Power Tool Cleaning.
CORROSIVE SERVICE: SSPC–SP6 or 10 Commercial or Near White Metal Blast
Cleaning. Use inhibitive primer such as PICCO – 19 or 29 Series prior to top coating.
PREVIOUSLY PAINTED SURFACES:
Remove all grease, oil, dirt, dust or other contaminants. Surface must be clean and dry,
SSPC–SP2 or 3 or SSPC-SP7. Spot prime bare areas before coating.
RECOMMENDED PRIMER/TOP COAT:
PICCO 19 or 29 Series Inhibitive Primers
SAFETY INFORMATION DOT CLASSIFICATION: PAINT UN 1263
DANGER: Causes eye burns and skin irritation. Vapor harmful. Dried film of this paint may
be harmful if eaten or chewed. Contains organic solvent. Some products contain lead depending
upon color. Do not get in eyes, on skin or on clothing. Wear eye protective equipment when
handling. Keep away from heat, sparks, and flame. Avoid breathing vapor or mist. Wash
thoroughly after handling. Wear appropriate, properly fitted respirator (NIOSH/MSHA approved)
during and after application unless air monitoring demonstrates vapor/mist levels are below
applicable level. Follow respirator manufacturer’s directions for use. Keep container closed.
Where products contain lead, do not use in dwellings or on surfaces accessible to children. Keep
out of reach of children.
FIRST AID: IN CASE OF EYE CONTACT, IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES. CALL A PHYSICIAN. FOR SKIN CONTACT, FLUSH WITH WATER AND WASH WITH SOAP
AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE. IF INHALED, REMOVE
TO FRESH AIR. IF NOT BREATHING GIVE ARTIFICIAL RESPIRATION, PREFERABLY MOUTH-TO-MOUTH, AND
CALL A PHYSICIAN.
NOTICE: Reports have associated repeated and prolonged overexposure to solvents with
permanent brain and nervous system damage. Intentional misuse by deliberately concentrating
and inhaling the contents may be harmful or fatal.
FOR INDUSTRIAL USE ONLY
14-Series Fast Dry Industrial Enamel
Page 2 of 2
September 2008