0% found this document useful (0 votes)
125 views4 pages

Engsolutions RCB: Wind Loads Nsr-10

This document contains the results of a wind load analysis for a building project called "VIENTO". It provides wind loading parameters such as basic wind speed, importance factor, exposure category, and pressure coefficients. It then calculates wind forces and overturning moments for the building in both the X and Y directions. The base shears and overturning moments are relatively small compared to the building weight and stabilizing moment, indicating the building has adequate strength for the wind loads.

Uploaded by

JohanMiranda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
125 views4 pages

Engsolutions RCB: Wind Loads Nsr-10

This document contains the results of a wind load analysis for a building project called "VIENTO". It provides wind loading parameters such as basic wind speed, importance factor, exposure category, and pressure coefficients. It then calculates wind forces and overturning moments for the building in both the X and Y directions. The base shears and overturning moments are relatively small compared to the building weight and stabilizing moment, indicating the building has adequate strength for the wind loads.

Uploaded by

JohanMiranda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

EngSolutions RCB Version 8.8.4 - License No: A27996-A21317 Page No.

1
============================================================================================
Company: INGENIEROSMIR Engineer: WRR
Project: VIENTO 10:21:15 p. m. 27/08/2019
File: C:\Users\JoseJ\Documents\edgar garcia 2019\RAUL GOMEZ.rcb
============================================================================================

WIND LOADS NSR-10


Wind pressure
p = q G Cp rigid buildings
= q Gf Cp flexible buildings
qz = 0.00483 Kz Kzt Kd V² I (Kg/m²); V in Km/h

W I N D L O A D I N G P A R A M E T E R S

Basic wind speed (Km/h), V ....... = 80

V: 3-second gust speed at 10 m, with annual probability of 0.002

Importance factor, I ............. = 1.0

OCCUPANCY CATEGORY IMPORTANCE F A C T O R


(1) (2)
I Normal occupancy buildings 0.87 0.77
II Especial occupancy buildings 1.00 1.00
III Public assistance facilities 1.15 1.15
IV Essential facilities 1.15 1.15
(1): Non-hurricane prone regions with V=140-160 km/h
(2): Hurricane prone regions with V >160 Km/h

Exposure category ................. = C

ROUGHNESS DESCRIPTION
B Urban and suburban areas, wooded areas, obstructions >30ft
C Open terrain with scattered obstructions less than 30 ft
D Flat, unobstructed areas, wind over large bodies of water

Directionality factor, Kd ......... = 0.85

Topographic factor, Kzt ........... = 1.0

Kzt = (1 + K1 K2 K3)²

Wall pressure coefficients, Cp

Windward wall .............. = 0.8


Leeward wall (Wind X) ...... = -0.5
Leeward wall (Wind Y) ...... = -0.46
Side walls ................. = -0.7
Roof ....................... = 0.0

______________________________________________________________________

G U S T E F F E C T S F A C T O R S

Basic wind velocity, (Km/h) = 80


Exposure category ......... = C
Exposed height, (m) ...... = 7.35

X-direction Y-direction
----------- -----------
Estimated natural frequency, f(Hz) = 3.069 3.069
Height / Length ratio, H/L ....... = .762 .635
Structure clasification .......... = RIGID RIGID

Background response index, Q ..... = .906 .912 (Eq. B.6.5-4)


Resonant response factor, R1 *.... = .073 .079 (Eq. B.6.5-8)
Gh: Rigid - Simplified analysis .. = .85 .85 (Sec B.6.5.8.1)
Gh: Rigid - Complete analysis .... = .872 .875 (Eq. B.6.5-2)
Gf: Flexible -Analytical(2% dampng)= 1.115 1.12 (Eq. B.6.5-2)
Gf: Flexible -Analytical(1% dampng)= 1.116 1.121 (Eq. B.6.5-2)

Gust effects factor, G ........... = .872 .875

* 1% damping ratio. For damping ratio ß, R = R1 * (0.01/ß)^½

______________________________________________________________________
EngSolutions RCB Version 8.8.4 - License No: A27996-A21317 Page No. 2
============================================================================================
Company: INGENIEROSMIR Engineer: WRR
Project: VIENTO 10:21:15 p. m. 27/08/2019
============================================================================================

V E L O C I T Y P R E S S U R E

Floor Height Pressure


- z, m qz, K/m2
------ ------- --------

CUB 7.34 24.913


3 4.84 22.826
2 2.34 22.545
1 0.0 22.545

______________________________________________________________________

A C C I D E N T A L T O R S I O N F O R W I N D L O A DS

X-direction Y-direction
----------- -----------

Accidental eccentricity as a
percentage of building dimension, (%)= 15 15

WY is Envelope of: WX is Envelope of:


Case 1: Pwy + Ply Case 1: Pwx + Plx
Case 2: 0.75 (Pwy + Ply) + Mt Case 2: 0.75 (Pwx + Plx) + Mt
Mt=0.75(Pwy+Ply)Bx ex Mt=0.75(Pwx+Plx)By ey
NOTE: Load cases 3 and 4 are handled through load combinations

______________________________________________________________________

A C C I D E N T A L E C C E N T R I C I T Y W I N D L O A D S

X-DIRECTION (WY) Y-DIRECTION (WX)


----------------- ------------------
Level ex ey
- (m) (m)
----- --------- ---------

CUB 1.45 1.74


3 1.45 1.74
2 1.45 1.74

WY is Envelope of: WX is Envelope of:


Case 1: Pwy + Ply Case 1: Pwx + Plx
Case 2: 0.75 (Pwy + Ply) + Mt Case 2: 0.75 (Pwx + Plx) + Mt
Mt=0.75(Pwy+Ply)Bx ex Mt=0.75(Pwx+Plx)By ey
NOTE: Load cases 3 and 4 are handled through load combinations

______________________________________________________________________
EngSolutions RCB Version 8.8.4 - License No: A27996-A21317 Page No. 3
============================================================================================
Company: INGENIEROSMIR Engineer: WRR
Project: VIENTO 10:21:15 p. m. 27/08/2019
============================================================================================

Wind nodal forces:


Pw = Σ pz Ai Pl = Σ ph Ai
Ps = Σ ph Ai Pr = Σ ph Ai
Ai = Nodal tributary area

W I N D F O R C E S: X - D I R E C T I O N

Floor Height Windward Leeward Side Roof


No z, m Pw, Ton Pl, Ton Ps, Ton Pr, Ton
------ ------- -------- -------- -------- --------
CUB 7.34 0.25 0.16 0.18 0.0
3 4.84 0.46 0.31 0.37 0.0
2 2.34 0.44 0.30 0.36 0.0
1 0.0 0.20 0.14 0.08 0.0

Base shear, V:Σ(Pw+Pl) .. = 2.26 ton


Building Weight, W ....... = 245.19 ton (V/W = 0.009)
Overturning moment
From horizontal forces . = 8.52 ton-m
From roof forces ....... = 0.0 ton-m
Total moment, Mo ....... = 8.52 ton-m
Stabilizing moment, Ms.... = 965.00 ton-m (Mo/Ms = 0.009)

______________________________________________________________________
EngSolutions RCB Version 8.8.4 - License No: A27996-A21317 Page No. 4
============================================================================================
Company: INGENIEROSMIR Engineer: WRR
Project: VIENTO 10:21:15 p. m. 27/08/2019
============================================================================================

Wind nodal forces:


Pw = Σ pz Ai Pl = Σ ph Ai
Ps = Σ ph Ai Pr = Σ ph Ai
Ai = Nodal tributary area

W I N D F O R C E S: Y - D I R E C T I O N

Floor Height Windward Leeward Side Roof


No z, m Pw, Ton Pl, Ton Ps, Ton Pr, Ton
------ ------- -------- -------- -------- --------
CUB 7.34 0.21 0.12 0.22 0.0
3 4.84 0.39 0.24 0.44 0.0
2 2.34 0.37 0.23 0.43 0.0
1 0.0 0.09 0.06 0.20 0.0

Base shear, V:Σ(Pw+Pl) .. = 1.70 ton


Building Weight, W ....... = 245.19 ton (V/W = 0.007)
Overturning moment
From horizontal forces . = 6.88 ton-m
From roof forces ....... = 0.0 ton-m
Total moment, Mo ....... = 6.88 ton-m
Stabilizing moment, Ms.... = 1224.09 ton-m (Mo/Ms = 0.006)

______________________________________________________________________

You might also like