sect.

20 97050
rev. 2015/09/28

Digital Tach/Hourmeter w/Adjustable Overspeed Trip Point


SHD30 and SHD30-45 Models
The SHD30 and SHD30-45 are microprocessor-based
tachometers with hourmeter and an overspeed trip
point. The trip point can be connected as either a form
C relay output or as a normally open SCR output for
alarm or shutdown on overspeed.
The SHD30 features a panel-mounting design, plastic
enclosure that is 5-1/16 (129 mm) long and 4-1/4 in.
(108 mm) high.
The SHD30-45 has the same enclosure, but it also has
a backplate with studs to mount like an OPLFC.
The SHD30 models power and RPM data are supplied *
by either a magnetic pickup or a capacitor discharge
(CD) ignition. The hourmeter is adjustable to a preset * When installed per Murphy drawing 20-08-0258
time and resettable to zero. Should power be lost, on-
board batteries maintain the run hours display and allow Specifications
for resetting the overspeed relay output.
When a tach signal is present the SHD30 models Power input:
display RPM. When a tach signal is not present, the CD ignition:
display is blank unless the Read Hours membrane key 90 to 350 VDC
on the faceplate is pressed and held. 150 µA typical @ 90 VDC
The five-digit, liquid crystal display is updated every 300 µA @ 350 VDC
second. The run hours, overspeed set point and current Magnetic Pickup:
pulses per engine revolution can be displayed by 5 to 120 Vrms
manipulating the membrane switches. Run hours can be 325 µA typical @ 5 Vrms, 100 Hz
displayed even after power is lost. The run hours display 450 µA typical @ 5 Vrms, 1 kHz
can be configured to alternate with the RPM display. 1 mA typical @ 5 Vrms, 5 kHz
2 mA typical @ 5 Vrms, 10 kHz

Ease of Calibration 15 mW max. @ 5 Vrms, 10 kHz


2.8 W max. @ 120 Vrms, 10 kHz
The SHD30 models calibration is accomplished by Backup Batteries: 2 replaceable, long-life Lithium batteries, Panasonic
entering the number of pulses per engine revolution CR2032 or equivalent, 3 V, 220 mAh power. Shelf life expectancy 10
using the Pulses per Revolution and Overspeed Set years
point membrane keys on the faceplate. The number Operating Temperature: -4° to 158°F (-20° to 70°C)
of pulses is determined by the number of cylinders, Storage Temperature: -40° to 300°F (-40° to 150°C)
cycles and ignition features. It is also determined by the Case Material: Plastic
number of ring gear teeth of the engine’s flywheel on a Ignition Frequency Range: 3 to 666 Hz
magnetic pickup system. Magnetic Pickup Frequency Range: 1 to 10 kHz
Presetting and resetting running hours is done from the Overspeed Output:
back and front of the SHD30 models. Connected to S.C.R. (Silicon Controlled Rectifier) terminals:
0.5 A, 350 VDC continuous

Applications Connected to Form C Relay terminals:


Relay Contact, 0.5 A, 30 VDC, 125 VAC resistive
• Gas Compressors Tachometer Accuracy: ±0.5% of the display reading or ±1 RPM which-
• Oil Field Equipment ever is greater
• Industrial Engines Hourmeter Range: 0 to 65535 hrs
• Generators Hourmeter Accuracy: ±15 minutes per year
Laboratory Approvals: CSA (Canadian Standards Association) approved
for Class I, Division 2, Groups C & D hazardous areas
Shipping Weight: 1 lb (0.5 kg)
Shipping Dimensions: 9-1/4 x 8-1/4 x 5-1/4 in. (235 x 210 x 133 mm)

In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. MURPHY products and the Murphy
logo are registered and/or common law trademarks of Enovation Controls, LLC. This document, including textual matter and illustrations, is copyright protected by Enovation Controls, LLC,
with all rights reserved. (c) 2015 Enovation Controls, LLC. A copy of the warranty may be viewed or printed by going to http://fwmurphy.com/warranty.
Dimensions

SHD30

SHD30-45 Typical Wiring Diagram

WARNING: In hazardous areas the overspeed relay contact is certified for use
ONLY with Murphy non-incendive or intrinsically safe products. In non-hazardous
areas overspeed relay contact may be used to switch electromechanical
Tattletale® or Magnetic Switches that do not exceed the relay contact rating: 1 A,
30 VDC; 0.3 A, 110 VDC; 0.5 A, 125 VAC. However, the preferred output to switch
electromechanical Tattletale® or Magnetic Switches is the N.O. SCR.

How to Order

Part Number Model and Description Notes


SHD30 Tach/Hourmeter with Overspeed
Specify Model
Number SHD30-45 Tach/Hourmeter with Overspeed to mount like SHD45
or OPLFC
00009389 Panasonic CR2032 or equivalent backup battery (2 required)