Model Cgo Model Cgo HTD Forced Draft Burners GAS Light Oil 98,000 - 19,100,000 Btu/Hr
Model Cgo Model Cgo HTD Forced Draft Burners GAS Light Oil 98,000 - 19,100,000 Btu/Hr
98,000 -
MODEL CGO HTD LIGHT OIL 19,100,000
FORCED DRAFT BTU/HR.
BURNERS
Power Flame’s The Power Flame Model CGO stable performance in both positive
Versatile High Performance dual fuel burner presents optimum or negative combustion chambers.
Gas-Light Oil Burner state-of-the-art design for maxi- Operating system adjustments have
mum combustion efficiency and been minimized to provide trouble-
operating dependability. These free start up and operation.
packaged combustion systems The Model CGO provides efficient
will fire all types of gaseous fuels, combustion without the aid of refrac-
Adjustable Premix Firing Head as well as #2 or similar distillate tory or other costly flame support
Produces optimum fuel-air liquid fuels. The Model CGO HTD devices. Options include the premix
mixture within the premix (High Turndown) will fire natural and low gas pressure firing heads
combustion zone* gas at turndowns up to 10 to 1. for limited size combustion chamber
Circular Furnace Opening The flame retention firing head configurations or low gas pressure
No special cutting of combustion incorporates a single nozzle pres- conditions. Modular design pro-
chamber front plate sure atomizing assembly for liquid duces added flexibility for a wide
fuels and a nozzle mix multiport range of optional features. All Power
combustor for gaseous fuels. The Flame packaged combustion
unique air sandwich systems are factory fire-tested.
firing head design
produces Alpha System™
Low Gas Pressure LED indicators, switches and
Firing Head full range
operator annunciator. (Optional
Added flexibility of additional 6-light board shown on
application for low gas right.)
pressure conditions*
STANDARD EQUIPMENT
Alpha System™ LED indicators (power, demand, main fuel,
FSG alarm, customer selectable) & control switch
Pressure regulators, pilot and main gas cocks
Oil valve, nozzle assembly, manual fuel selector switch
Air safety switch & leakage test cock
Gas electric pilot and gas ignition transformer
ADDED FEATURES C1-GO-10
C1-GO-12
C3-GO-20
C3-GO-25
C4-GO-30 C7-GO-30
C5-GO-30(B) C8-GO-30
X-Standard O-Optional NA-Not Available C2-GO-15 C2-GO-20A C2-GO-20B C3-GO-25B C4-GO-25 C6-GO-30
Flame Safeguard with UV and prepurge with interrupted pilot X X AX AX AX AX AX
On-Off diaphragm gas valve with fixed air control manual adjustment X NA NA NA NA NA NA
Low-Hi-Off motorized gas valve with automatic air control O X X X X NA NA
Low-Hi-Low motorized gas valve with automatic air control O O O O O NA NA
Modulation with automatic air control O O O O O X X
Integral 2 stage fuel unit (C1, C2 single stage) X X X X X NA NA
Remote mounted 2 stage fuel unit (single stage for C6-C8) O O O O O X X
Dual gas B and dual oil safety valves X X X X X X X
High and Low gas pressure switches O O X X X X X
Direct spark ignition (oil) O O O O O O O
Low fire oil start with automatic air control O X X X X X X
Man/Auto switch - manual potentiometer - modulation only X X X X X X X
A Postpurge standard on C2-GO-20B and all C3 to C8 models B 5,000 MBH and below may be replaced by one (1) proof of closure valve; above
Conforms to UL 296 and UL 795 5,000 MBH one (1) of the safety valves will include proof of closure feature.