DATASHEET
SIEMENS
6SE7090-0XX84-0FB0
OTHER SYMBOLS:
6SE70900XX840FB0, 6SE70900XX84 0FB0, 6SE70900XX84-0FB0, 6SE7090 0XX840FB0, 6SE7090 0XX84 0FB0,
6SE7090 0XX84-0FB0, 6SE7090-0XX840FB0, 6SE7090-0XX84 0FB0, 6SE7090-0XX84-0FB0
RGB ELEKTRONIKA AGACIAK CIACIEK
SPÓŁKA JAWNA
Jana Dlugosza 2-6 Street
51-162 Wrocław www.rgbelektronika.pl
Poland
[email protected]
+48 71 325 15 05
www.rgbautomatyka.pl
www.rgbautomatyka.pl
www.rgbelektronika.pl
YOUR
PARTNER IN
MAINTENANCE
Repair this product with RGB ELEKTRONIKA ORDER A DIAGNOSIS ∠
LINEAR
ENCODERS PLC
SYSTEMS
INDUSTRIAL
COMPUTERS
ENCODERS CNC
CONTROLS
SERVO AMPLIFIERS
MOTORS
CNC
MACHINES
OUR SERVICES
POWER
SUPPLIERS
OPERATOR
SERVO
PANELS
DRIVERS
At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair
works and test each later sold unit. Our trained employees, equipped with a wide variety of tools and
having several testing stands at their disposal, are a guarantee of the highest quality service.
Buy this product at RGB AUTOMATYKA BUY ∠
SIMOVERT MASTERDRIVES Motion Control
Selection and ordering data
Compact Compact and
Converters and inverters PLUS units chassis units
Electronics options · Board/slot preconfiguration1)
Designation Order No. Supplementary Weight, Dimensions
order code6) approx. WxHxD
kg mm x mm x mm
(lb) (in x in x in)
Encoder boards (An encoder board must always be ordered. Exception: V/f control)
SBP Incremental-encoder evaluation HTL/TTL (Impuls-encoder evaluation)
Spare part2) 6SE7090–0XX84–0FA0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0FA00
Plugged into slot A4) C11
Plugged into slot B4) (only for Compact PLUS units!) C12
Plugged into slot C4) (motor encoder) C13
Plugged into slot D4) (only for compact C14
Plugged into slot E4) and chassis units) C15
3 Plugged into slot F4)
Plugged into slot G4)
C16
C17
SBR1 Resolver evaluation without incremental-encoder simulation
Spare part2) 6SE7090–0XX84–0FB0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0FB00
Plugged into slot C4) C23
SBR2 Resolver evaluation with incremental-encoder simulation
Spare part2) 6SE7090–0XX84–0FC0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0FC00
Plugged into slot C4) C33
SBM Absolute-value encoder evaluation/incremental-encoder evaluation sin/cos 1 Vpp (only as spare part for existing systems)
Spare part2) 6SE7090–0XX84–0FD0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
SBM2 Absolute-value encoder evaluation/incremental-encoder evaluation sin/cos 1 Vpp (MC firmware versions ³ 1.3)
Spare part2) 6SE7090–0XX84–0FE0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0FE00
Plugged into slot C4) (motor encoder) C43
Plugged into slots A, B, D, E, F, G4) (machine encoder) C41/C42/C44 to C47
Expansion boards
EB1 Expansion board
Spare part2) 6SE7090–0XX84–0KB0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0KB00
Plugged into slots A to G4) G61 to G67
EB2 Expansion board
Spare part2) 6SE7090–0XX84–0KC0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0KC00
Plugged into slots A to G G71 to G77
Drive coupling (rapid data exchange via fiber-optic cable)
SLB for SIMOLINK
Spare part2) 6SE7090–0XX84–0FJ0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3)5) 6SX7010–0FJ00
Plugged into slots A to G4)5) G41 to G47
Communication boards (for slot location, see page 6/60)
CBP2 for PROFIBUS DP
Spare part2) 6SE7090–0XX84–0FF5 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0FF05
Plugged into slots A, B, C, E, G G91/G92/G93/G95/G97
CBC for CAN
Spare part2) 6SE7090–0XX84–0FG0 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
Retrofit kit3) 6SX7010–0FG00
Plugged into slots A, B, C, E, G G21/G22/G23/G25/G27
CBD Communication Board DeviceNet 6SX7010–0FK00 0.3 (0.7) 20 x 90 x 95 (0.8 x 3.5 x 3.7)
for DeviceNet
1) The Compact PLUS units have three slots 3) For retrospective mounting. The retrofit kit usu- 5) With 2 FOC connectors, 1 connector for X470
A, B and C. Compact and chassis units can be ally contains a board, plug-in connector and and 5 m all-plastic FOC (fiber-optic cable).
expanded to have up to 6 slots, A, C, D, E, F documentation but not adapter boards or LBA
6) When ordering the board, “–Z” and the corre-
and G. For the various possible configurations, (see Page 3/8).
sponding code for direct mounting in the
see Page 6/61.
4) With appropriate connector. corresponding slot must be appended to the
2) Excluding connector, excluding documentation. converter/inverter order no.
3/6 Siemens DA 65.11 · 2003/2004