uter Body Parts Password Change ● To register multiple cards or key tags, lightly place another card or key tag
[Deleting Cards] [Deleting ID information]
3. Reading the card to be deleted 3. Enter ID number to delete
Number Pad Lighted to the card reader within 20 seconds after registering the previous card or
This section contains important information to ensure the user’s The password can be 4~12 digits number. Only one password can be key tag.
safety and prevent potential damage to property. Please, read
Number Pad Unlighted registered. Warning ● ID number is given automatically in order of the registration.
Warning this section carefully and use the product accordingly. DING DONG DING DONG
1. Pressing the [Register] Button 2. Entering the Current Password
(from the inside) (from the outside) [Card and user password registration with ID number] DENG DENG
SHS-H505
• The user shall not install or repair the responsibility for any harm caused Number Pad
product without authorization. by engagement of the lock on an 3. Enter 2 digits ID number 4. Enter new user password
improperly closed door.
DING DONG DING DONG If you want to delete all cards data, press Enter 2 digits ID number, then the
• Do not install the product in the place [88] + [] after step 2. card or user password of it will be
DENG, DING DING
where the gap between the door and the • Please do not hang on the product or LED Indicator
frame is 5mm or more. pull it.
deleted.
64&3."/6"- • Make sure that no unauthorized person • Be sure to correctly match the poles Card Reader Press the [Register] button Enter the current password when the
DING DING DING DONG
has the access to the password.
• Do not operate the product with wet
(+/-) when installing the batteries. Install
the batteries with the correct poles (+/-).
External Power Port briefly. number pad is lighted, and press the
DENG
Double Authorization Mode Setting
[] button.
hands, and keep liquids such as water • Replace all batteries immediately after Reset
or drinks away from the product, or they run out of power, and never mix Input ID between 01 and 30, and Enter new user password(4 to 12 Double authorization mode requires both card and password to open
Switch 3. Entering a New Password 4. Checking New Password
the product may malfunction or be new batteries with used ones. press []. digits) and press []. the door, ensuring more security.
damaged. • Do not use water, benzene or alcohol (from the outside) Operation (from the outside)
Outer Body Handle DING DONG
• Do not use the excessive force or sharp when cleaning the product, as these
objects to push the lockbuttons, as this fluids can cause product malfunction. To make sure the DENG
can damage the product. DING DONG password has been 4. Placing the Card or Key Tag 5. Confirming Card or Key Tag DING DONG [4] Button : Double
• Replace the batteries within 1 week Emergency properly registered,
• Make sure that the door is completely after the battery replacement alarm Keyhole DENG on the Card Reader (from the Registration (from the outside) authorization mode on
check the new outside) [6] Button : Double
Convenient Opening closed when going outside. The sounds.
Enter the new password (4 to 12 password and close authorization mode off
- User friendly access with manufacturer does not assume the Inner Body Parts digits) and press the [] button. the door.
cards and password Briefly press the [Register] Press the [] button after pressing the
※ In order to safely use the product, please read “Safety Precautions”. DING DONG
Graphic Interface button on the inner body. [4] or [6] button, and the authorization
※ The features of this product and the contents of the user guide may be changed ● M
anage your password with care so that unauthorized people will not have DENG
- Shows the operation status mode will be set.
without notice for quality improvement. access to it. Regularly changing your password can reduce the risk of it
of the doorlock
Warning being leaked.
Double Authorization
- Requires card & password
Product Components Place the card or key tag to be registered on Place the registered card or key ● The setup of double authorization mode only works when the door is open.
● When purchased, the product is not set to double authorization mode initially.
combination to open
The product components used may vary depending on the installation Battery Cover Card and Key Tag Registration the card reader of the outer body. You will tag to the card reader on the outer
know the card or key tag has been registered body.
Note ● To setup the double authorization mode, more than 1 card must be
registered.
Double Locking environment. when “DING DONG DENG” sounds.
- Prevents opening from outside Up to 30 cards, including the key tag and user password, can be registered. ● Double authorization mode will automatically be turned off when all cards are
(Do not disturb) Sound Control deleted.
Switch 1. Pressing the [Register] 2. Entering the Current Password ● User password is only for the user, so other functions such as registering
Built-in Fire Detection Auto/Manual Button (from the inside) (from the outside) cards are not available with this password.
- Generates alarm in case of a fire Locking Switch Warning ● One ID has only one password or card. Automatic/Manual Locking Setting
Security Function Registration CLOSE Button
- Prevents intrusion from the outside Button
DINGDONG DING DONG
The Automatic Locking mode allows for automatic locking of the door when
Manual Open-
Mortise
(SHS-AML320)
Strike Inner body
Handle
and close
Lever
DENG, DING DING Deleting Registered Cards it is closed.
Or Open the battery cover of the Enter the current password (‘1234’ after You can delete individual or all registered cards.
inner body and briefly press initialization) when the number pad is Set the [Automatic/Manual Locking] toggle switch of
the [Register] button. lighted, and press the [] button. the Inner Body to the ‘A’/‘M’ position.
1. Pressing the [Register] 2. Entering the Current Password
Button (from the inside) (from the outside)
[Card and Key Tag Registration Without ID number]
Mortise - Automatic: The door is automatically locked 2 seconds after being closed.
3. Placing the Card or Key Tag on the 4. Confirming Card or Key Tag -M anual: The door does not lock automatically, and [CLOSE] button must be
Outer Body Mortise Strike Strike Inner Body Card Reader (from the outside) Registration (from the outside) DING DONG DING DONG pressed from the inside, touch [Number Pad] to close the door.
(SHS-AML220) box DING DING DENG, DING DING
Menu Table Opening the Door from Outside with a Password Opening the Door from the Inside Sound Setting and Releasing Setting the Security Function Using the Emergency Battery
When purchased, the product is set to Multi-leveled Security Code Entry Pulling down the Door Lock Rotating the Manual Open/ The sound that is generated when the number buttons are pressed, when the Setting the Security Function Releasing the Security Function If the batteries are not replaced after their replacement time comes, they
Initialization door is locked or when the locked door is unlocked, can be set according to
Mode initially. Please refer to “Multi-leveled Security Code Entry Mode Handle Close Lever to the Right or Left will be completely discharged and the lock will not operate.
5S setting” for Common Mode setting. the user’s preference. The product is set to generate all sounds at the factory. DING DONG
4560852580 DENG Or Opening the Door Using an Emergency Battery
※ Silent Mode WTXTY CARD
Before entering the password, press the [] button and enter the Purchase an emergency battery (9V) at the nearest store.
DING DONG
password, then both the sound of the key entering and the door opening DENG - As the alkaline batteries offer longer life, they are recommended
Registration After touching the Number Pad,
will be suspended. It is a useful function if you do not want to disturb 1. When the door is closed [ ] of the over the manganese batteries or rechargeable ones.
neighbors when you go in and out at night. outside body’s number pad will light up. contact a registered card, or enter the
Changing password Open the battery cover on the inner Put the [Sound Control] switch password and then press the
Password New Password 2. Press and hold the [ ] button on the
body. on one of [0], [1], or [2], and [] button. Place the card or key tag on the
close the battery cover. outer body for 3 seconds while the door card reader, or enter the password,
Direct registration of Rotate the door lock handle of the Rotate the manual Open/Close is locked. Or
Card or key tag Success: [0] : Mute [1] : Normal [2] : Loud while the 9V battery is connected
CARD DING DONG DENG
inner body downward. lever to the right or left to lock the
to the external power port of the
Fail: door or release the locking. ● The security function is automatically released when the locked door is
outer body.
Card or user password
with ID number (01~30)
DING DONG DING
DONG Multi-leveled Security Code Entry Mode Setting Note
opened from outside by entering the registered password or applying the card
or key tag to the card reader.
ID Number CARD
Touching [Number When two arbitrary buttons When the numbers on the Closing the Door from the Inside You can set the security mode suitable for your use when you open the door
using a password.
Pad] will light up are lighted, press the buttons number pad are lighted, enter
Alarm Sound (Prank Prevention Function) Built-in Fire Detection Function
Deletion the number pad. in order. the password and press the [] Closing the Door from the Inside In the Manual Locking Mode DING DONG
button. DENG This function generates the alarm sound when fire is detected so that
3S Card or key tag [7] Button : Multi-leveled This function generates an alarm sound and deactivates lock operation the residence can quickly respond. The built-in fire detection function
Password CARD DING DONG when it is improperly handled from the outside.
Security Code Entry
- If the security mode is changed as ‘common mode’, second step will be skipped.
Mode
is a basic function of the lock, and cannot be released by the user.
Use index number This alarm will sound if an attempt is made to open the door with an invalid card, Fire detection function is operational at about 75 ℃ ± 10 ℃; this can
ID Number
[9] Button : Common Mode
or if a wrong password is entered five times in a row. vary depending on the installation environment.
●P
assword must be entered after the light is on, and if does not, touch [Number Pad]
The alarm sound is generated, and the lock is deactivated for 3 minutes. While
and re-enter. Briefly press the [Register] Press the [] button after pressing the When fire occurs, the temperature sensor detects it and flashes the [Close]
All user password/card button on the inner body. [7] or [9] button, and the security mode the door is in this inactive mode, a single “DING” sound is generated every 10
88 Note ● T o cancel, press [ ] button and re-enter. button while generating the alarm sound. The door is automatically opened
will be set. seconds and seven consecutive “DINGS” will sound after 3 minutes. Following
● If the password is wrong 5 times, “peep” warning alarm will sound 20 times and SHS-AML320 SHS-AML220 after the alarm sound has stopped. (The lock resumes normal operation if the
the system will shut-down for about 3 minutes. When malfunction happens, “beep” this, the lock is released from inactive mode.)
inside temperature returns to a normal level.) The built-in fire detection
Other function
will sound every 10 seconds, and stop mode will be turned off automatically after 3
minutes with multiple ‘beeps’. The door is automatically locked The door is locked when the [Close] Setting the Double Locking Releasing the Alarm function is activated when the temperature rises around 60°C, which may
2 seconds after the door is closed. button is pressed, or the manual Open/ Inside Press the [Register] button. differ depending on the installation environment.
Double Authorization Close lever is rotated. The double locking function prevents opening of a locked door from outside. Outside Get a registered card authorized or enter the password and then
4 ON
Setting Double Locking Releasing Double Locking press the [] button.
Product Specifications
6 OFF Opening the Door from Outside with a Card or Initialization (Password, Card, Key Tag)
Multi-leveled Security Code Key Tag DING DONG Replacing the Batteries Item Specifications
7 ON All registered data (password, card, key tag) are deleted. After DENG Voltage AA Alkaline 1.5 Batteries (LR6) 4EA or 8EA (6V)
The door can be opened from outside using a card or key tag. Battery Replacement Alarm Generation
initialization, the password is set to ‘1234’, and the registered card, key Emergency Power
9V Battery (6LF22) (Separately sold)
9 OFF
Place the registered card or key tag on the card reader. tag data are erased. Please register a new password after initialization. If the melody of “Blues for Elise” sounds when opening the door with the Source
Press the [Close] button for 2 The double locking function is released password or a card (key tag), it is time to replace the batteries. Electronic Control Method (Password entry or card or key tag
Operation Method
1. Pressing the [Register] 2. Entering the Numbers for seconds or longer from the inside when the inner body handle is rotated (The low battery indicator is lighted when the melody sounds.) reading)
1. Touch [Number Pad] 2. Placing the Card or Key Tag on the
Card Reader Button (from the inside) Initialization (from the outside) while the door is locked. downward, or the manual Open/Close Replacing the Battery Weight 2.6Kg (including both inner and outer bodies)
lever is rotated to the right or left. Outer Body
Replace all 8 batteries within a 1 week of the first alarm sound. (including the handle)
81.9 mm(W) x 302.4 mm(H) x 66.1 mm(D)
Product
Activating Double Locking Dimensions Inner Body
DING DONG ● If the poles of the batteries are not placed properly, the lock will not operate 79.0 mm(W) × 290.0 mm(H) × 80.3 mm(D)
CARD Success: DING DONG DENG DING DING
Inside : The double locking sound is (including the handle)
Fail: DING DONG DING DONG - Success: DING DONG DENG generated when the [Close] button is normally.
DING DING
DING DING
- Fail: DING DONG DING DONG Peep, pressed. Warning ● Liquid leaks from batteries can damage the product. Check the batteries ● The contents of this user guide are subject to change without prior notice to
Or Peep Outside : The double locking sound is regularly (every 6 months).
the user in order to enhance performance of the product.
Touching [Number Pad] will Place the card or key tag on the card reader. generated, the double locking display LED ● After the battery replacement alarm has sounded, password/card information
light up the number pad. The door will be opened after 1 second. Press and hold the [Register] When the number pad is lighted, enter is lighted, and the door cannot be opened cannot be registered, changed, deleted, initialized or configured until the
button for 5 seconds. ‘4560852580’ and then press the [] when touch [number pad], or a card is batteries are replaced.
button. applied. ● The unit will stop operating suddenly if the batteries are not replaced.
4 5 6 10 11 12
安全注意事项 室外锁体名称 更改密码 [通过ID号码进行卡和密码的注册] 设定双重安全模式
背景灯亮起
3.输入 2位数的ID号码 4. 输入新用户密码
密码可注册4~12位的一组,可注册一个密码,初始化操作后请重新 使用密码开门时,可根据适用性设定认证模式。
背景灯熄灭
为保证用户安全,避免给用户带来财产损失及使用不便,请务必 注册密码。 DING DONG
仔细阅读以下内容后正确使用本产品。 DING DING DENG
Warning 1. 按[设定]键(从室内) 2. 输入密码(从室外) DING DONG
SHS-H505
[7] 键: 双重安全模式
号码键盘
[9] 键: 普通模式
• 禁止用户任意安装或修理本产品。 • 禁止用力下坠或用力拉本产品。
DING DONG DING DONG DENG,
•安
装时,门与门框之间的间距不能超 •请
按照电池正负极 (+/-),正确安装 输入01~30以内的ID号码按下[*]键。 输入(4~12位数)的密码按下[*]键。 短按室内侧锁体的[设定]键。 按下[7]或[9] 键后,按下[]键即可
工作 LED DING DING
设定认证模式。
64&3."/6"- 过5mm以上。 电池。
电子卡感应区
•请
小心管理密码,并定期更换密码, •电
池寿命已尽时,请同时更换所有的电
外部电源接口
短暂的按下设定按钮。 按键板亮灯后 输入密码按下[]键。
4. 接触卡、Key Tag (从室外) 5. 接触卡、Key Tag(从室外) 设定双重认证模式
以免他人知道。 池,禁止新旧电池混合使用。
3. 输入新密码(从室外) 4. 再次输入新密码(从室外)
止用湿手操作本产品,防止水、饮料 • 请使用柔软的布清洁锁体,禁止使用
•禁 复位键 双重认证模式是指开门时,需同时认证密码和卡的安全强化功能。
DING DONG DENG 根据使用需要,可以设定或解除该模式。
等液体进入锁体内部。 水、苯、酒精擦拭本产品。
DING DING DING DONG DENG
•禁
止过度用力或用尖锐的器具按电子 •产
生电池更换警报音后,请务必在一周 室外侧把手 DING DONG
锁的按键。 之内及时更换新电池。 DENG
将要注册的卡、Key Tag放到感应区, 注册过的卡、Key Tag放在感应区 DING DONG
应急钥匙插孔 [4]号: 设定双重认证模式
• 外出时请务必确认门是否完全上锁。 输新密码(4~12 位)后按[]键。 再次输入新密码按下[]键密码被保存。 随“DING DONG DENG”的声音完成注册。 1~5秒内锁会开启。 [6]号: 解除双重认证模式
άॆԅਪֺ 室内侧锁体名称
卡、密码简单的开门方式
※ 为保证使用安全,请务必在使用前仔细阅读“安全注意事项”。 ● 使用者密码是仅针对使用者而设定的密码
短按室内侧锁体的[设定]键。 按下[4]或[6]号键, 再按下[]键,
※ 本公司保留改进产品权利,产品性能及说明如有变更,恕不另行通知。 ● 注意管理密码,别泄漏给他人,一组密码不宜使用过长时间。 使用者密码不能用于卡注册或者其他类似的功能。
ᅱൟჰծٟટ Warning ● 一个 ID 只能标记一个密码或者卡。
即可设定解除认证模式。
工作状态LED灯提示
Warning
1. 若
门上锁,室外侧号码键盘的 将设定的电子卡、迷你卡置于感
DING DONG DENG DING DONG DENG [ ]键会亮起背光灯。 应区或者输入密码,然后按下
迷你卡(KEY-TAG) 把手连接杆 •室 内侧固定螺丝 将要注册的卡、Key Tag放到感应区, 注册过的卡、Key Tag放在感应区
Key tail 连接杆扣环 • 锁扣板固定螺丝 随“DING DONG DENG”的声音完成注册。 1~5秒内锁会开启。 2. 在
3 秒以内按下[ ]键, []键。
使用说明书 • 固定嵌板与室内侧锁 仅可设定防盗功能。
方舌
‘AA’电池(LR6) 体的固定螺丝 ● 想注册多张开门卡时,注册好第一张卡后在20秒内一次将剩余 需要删除所有卡时, 完成第2阶段操作后 输入要删除的卡或者使用密码的2位数
应急钥匙(5EA) • 固定嵌板与室外侧锁 斜舌 的卡放到感应区,如操作过程中间隔20秒以上会自动终止。
感应器 按下[88]+[*]。 ID号码。 ●即
使设定了防盗功能,从室外输入设定的密码或者将电子卡、
体的固定螺丝 Warning ● 登入用ID 号码为随机号码 迷你卡置于感应区将门打开后,防盗功能会自动解除。
Note
www.sds.samsung.com GC68-02070A ED:02
2 SHS-AML320 SHS-AML220 3 7 8 9