0% found this document useful (0 votes)
77 views32 pages

Accepted Manuscript: 10.1016/j.surfcoat.2017.03.009

The document describes a study on improving the corrosion resistance of arc thermal sprayed Inconel 625 coatings through sealing treatments. Inconel 625 coatings produced via arc thermal spraying have higher porosity and oxide content than HVOF coatings, resulting in poorer corrosion resistance. The study applies zinc powder, inorganic ceramic, and organic-inorganic composite ceramic sealing treatments to the Inconel 625 coatings and evaluates their effects on corrosion resistance through microstructure analysis and electrochemical experiments.

Uploaded by

Madhavi chitti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views32 pages

Accepted Manuscript: 10.1016/j.surfcoat.2017.03.009

The document describes a study on improving the corrosion resistance of arc thermal sprayed Inconel 625 coatings through sealing treatments. Inconel 625 coatings produced via arc thermal spraying have higher porosity and oxide content than HVOF coatings, resulting in poorer corrosion resistance. The study applies zinc powder, inorganic ceramic, and organic-inorganic composite ceramic sealing treatments to the Inconel 625 coatings and evaluates their effects on corrosion resistance through microstructure analysis and electrochemical experiments.

Uploaded by

Madhavi chitti
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

Accepted Manuscript

Corrosion behavior in seawater of arc thermal sprayed Inconel


625 coatings with sealing treatment

Il-Cho Park, Seong-Jong Kim

PII: S0257-8972(17)30245-1
DOI: doi: 10.1016/j.surfcoat.2017.03.009
Reference: SCT 22178
To appear in: Surface & Coatings Technology
Received date: 25 December 2016
Revised date: 2 March 2017
Accepted date: 3 March 2017

Please cite this article as: Il-Cho Park, Seong-Jong Kim , Corrosion behavior in seawater
of arc thermal sprayed Inconel 625 coatings with sealing treatment. The address for
the corresponding author was captured as affiliation for all authors. Please check if
appropriate. Sct(2017), doi: 10.1016/j.surfcoat.2017.03.009

This is a PDF file of an unedited manuscript that has been accepted for publication. As
a service to our customers we are providing this early version of the manuscript. The
manuscript will undergo copyediting, typesetting, and review of the resulting proof before
it is published in its final form. Please note that during the production process errors may
be discovered which could affect the content, and all legal disclaimers that apply to the
journal pertain.
ACCEPTED MANUSCRIPT
Corrosion Behavior in Seawater of Arc Thermal Sprayed Inconel 625 Coatings with
Sealing Treatment

Il-Cho Park, Seong-Jong Kim*

Division of Marine Engineering, Mokpo National Maritime University,


Mokpo-si, Jeollanam-do, Korea

*
Corresponding author

Prof. Dr. Seong-Jong Kim

PT
Mokpo National Maritime University

RI
91, Haeyangdaehak-ro, Mokpo-si, 58628, Korea

SC
E-mail: [email protected]

Tel.: +82-61-240-7226
NU
Fax: +82-61 240-7201
MA

Abstract
D

In this study, zinc powder (Zinc), inorganic ceramic (Ceramic), and organic-inorganic
TE

composite ceramic (Hybrid) sealing processes were applied to improve the corrosion

resistance of arc thermal sprayed Inconel 625 coatings. The Inconel 625 coating in seawater
P

solution showed poor corrosion resistance due to its porosity and Cr depletion resulting from
CE

Cr oxide formation during the arc thermal spraying process. Zinc sealing formed a stable
AC

cathodic protection, but the local corrosion damage occurred largely in the anodic polarization

experiment caused by an excessive dissolution reaction and a weak bonding force between the

zinc particles. Hybrid sealing gave a better sealing effect, but surface corrosion damage

appeared due to interconnected micro-crack defects on the surface. Ceramic sealing gave the

best corrosion protection due to a high sealing efficiency and a lower surface damage

tendency resulting from effectively blocked defects of the Inconel 625 coating.

Keywords: Inconel 625; ceramic sealing; corrosion; arc thermal spray; seawater
-1-
ACCEPTED MANUSCRIPT
1. Introduction

Corrosion resistance of the steel can be significantly enhanced by modifying the surface

with thermally sprayed anti-corrosion coatings [1,2]. The advantage of this method is the

substantial cost reduction compared to using bulk alloys [1]. The thermal spraying technology

can be divided into several processes according to the thermal energy source and the kinetic

energy of the sprayed materials, such as flame spraying, plasma spraying, arc thermal

PT
spraying, and high velocity oxy-fuel (HVOF) spraying [3]. Among these methods, long-term

RI
anticorrosion of the large steel structures in the marine environment has been effectively

achieved by arc thermal spraying technique as a cathodic protection method using the

SC
sacrificial anode [3]. Their materials as Al, Zn or Al-Zn, and Al-Mg alloys, etc. have been
NU
mainly used [4-6]. However, existing anti-corrosive materials are limited for the protection of

the steel in the severe corrosive environment where physical and mechanical forces are
MA

externally applied. To improve the corrosion resistance and durability of the steel substrate,

therefore, the attention about thermal spray coatings using high grade metallic alloys such as
D

Inconel, Hastelloy, Stellite or stainless steel type is growing recently [7,8]. In particular,
TE

HVOF coating using Inconel 625 powder is available in a wide range of aggressive conditions
P

which contribute to corrosion, erosion and overall wear of the surface [1,7,9-13]. The reason
CE

is that the HVOF spraying process has been developed to produce extremely high spray

particle velocities of 300-800 m/s to be coated for the substrate and the kinetic energy of their
AC

particles is therefore great [7,14]. Hence, the porosity of HVOF coatings is reduced to less

than 1%, and their oxide content is also very low [10,12,15]. However, deposited Inconel 625

coating for protection of the steel in the aqueous environment can be damaged by

electrochemical corrosion because the coating is not galvanically sacrificial against the steel

substrate. It is explained that interconnected porosity and oxide formation at the intersplats are

the principal microstructural features affecting the corrosion rate [7,8]. To solve these

problems, many researchers carried out various post-treatment onto the Inconel 625 coating
2
ACCEPTED MANUSCRIPT
by HVOF process. Neville et al. suggested that corrosion resistance of the coating might be

improved by post heat-treatment due to reducing the composition gradient through promoting

some inter-diffusion [16]. On the other hand, many researchers have investigated on the

application of laser surface melting. As a result, laser surface melting of Inconel 625 coating

has been shown to be able to significantly improve corrosion resistance. This is attributed to

microstructural homogenization such as the elimination of interconnected porosity and the

PT
structure consisting of splats, and reduction of composition gradient in the coating [11,12,17].

In spite of the above efforts, application of Inconel 625 coating onto the large steel structures

RI
in the marine environment is limited due to low productivity and difficulty of site

SC
constructability arising from the nature of HVOF spraying process. In this study, therefore,

the Inconel 625 coating was conducted by arc thermal spraying technique. This technique has
NU
good characteristics such as site constructability, low running costs, high spray rates and
MA

efficiency to coat large areas at the site [18]. However, arc thermal spraying has a lower

particle velocity of 100-300 m/s and lower temperature process compared to HVOF spraying
D

[18]. The combination of relatively low temperature and particle velocities gives arc sprayed
TE

coatings poorer bond strengths and higher porosity levels of 3-5% [18,19]. Moreover, the use

of compressed air for droplet atomization gives rise to high oxide content in the coating when
P

compared with HVOF spayed coatings [18]. Consequently, it is believed that corrosion
CE

resistance of Inconel 625 coating by arc thermal spraying technique will be poorer than that of
AC

HVOF coating resulting from high porosity and oxide content of the coating. Therefore, we

additionally carried out sealing treatment to improve the corrosion performance onto the arc

thermal sprayed Inconel 625 coating using three sealants, respectively. And then corrosion

resistance of Inconel 625 coating was evaluated by microstructure analysis and various

electrochemical experiments.

2. Experimental method
3
ACCEPTED MANUSCRIPT
The popular structural steel, A 36 by ASTM standard specification, was used as the

substrate specimen and its chemical compositions (wt. %) are as follows: 0.16% C, 0.19% Si,

0.36% Mn, 0.013% P, 0.011% S, and Fe balance. For surface preparation, a rough surface was

formed by grit blasting according to SSPC-SP10 standard to remove the foreign materials and

improve the adhesion between the substrate and the thermal spray coating. The grit blasting

was carried out using compressed air to form a surface roughness (Rmax) of about 80 ㎛. Arc

PT
thermal spraying method was used for this experiment, with a robot control system to

maintain constant spray conditions of the spray gun. (Model: ZPG-400B arc spray equipment,

RI
Shanghai Xinye Spray Machinery Co., Ltd) The spraying work was performed with twin

SC
wires of the Inconel 625. And then Hybrid, Zinc, and Ceramic sealing were applied to thermal

sprayed Inconel 625 coating by brushing. Hybrid sealing is an organic-inorganic composite


NU
ceramic product developed by Bukwang Korea Inc. Zinc sealing (product: ZINGA, Zinga
MA

Korea) is mainly composed of zinc powder with a purity of 99.995%, aromatic hydrocarbons,

and binder. Ceramic sealing (Product: 7053 HV-BP124N, Hankook Firetech co., Ltd) is
D

divided into the main agent and a harder. The main agent is made by adding distilled water to
TE

the cooled silicasol and epoxysilane and then it is allowed to react for 4-12 h at the room

temperature. The harder is manufactured by adding an amine and an alkoxysilane to isopropyl


P
CE

alcohol solvent. Then it induces a reflux reaction by increasing the temperature to 60℃.

Unreacted amines are removed by column chromatography. The structural formula of the
AC

main agent and the harder is shown in Fig. 1. Details of the arc thermal spraying parameters

and the sealing conditions are given in Table I and Table II, respectively. Every

electrochemical experiment was performed in the natural seawater with a working electrode

of the exposed area of 1 cm2, Ag/AgCl (KCl saturated) as a reference electrode, and the

platinum mesh as a counter electrode of the size of 2.5 cm x 2.5 cm. (Model: US/PCI4/750

Potentiostat/Galvanostat/ZRA, Garmy Instruments, Inc.) The distance between the working

electrode and the counter electrode was kept at 8 cm using the flat corrosion cell. The main

4
ACCEPTED MANUSCRIPT
chemical compositions (wt. %) of the natural seawater are as follows: 30.62% Na+, 3.68%

Mg2+, 1.18% Ca2+, 1.10% K+, 55.07% Cl-, 7.72% SO42-, and 0.63% others. The corrosion

potential measurement was conducted for 10 h, and the initial stabilization time for

polarization experiment was set to 3,600 seconds. The anodic polarization experiment was

performed in the open circuit potential (OCP) at the scan rate of 2 mV/sec up to +3.0 V.

Besides, after polarization to ±0.25 V at the OCP, the corrosion current density and corrosion

PT
potential were determined by a Tafel’s extrapolation method. After the anodic polarization

experiments, the surface damage morphologies were observed by scan electron microscope

RI
(Model: S-2150, Hitachi) and 3D microscope (Model: Nextop-3D, Nextec). The porosity

SC
measurement of the Inconel 625 coating was evaluated through image analysis (Image

analysis software: i-Solution DT, IMT i-Solution Inc.) and its value was averaged at five
NU
points on the cross section of the coating. An energy dispersive spectrometer (EDS), Model
MA

EX-250 by HORIBA, was used to characterize the structure of the coating. And the

micro-Vickers hardness (Equipment Model: HMV-2E-125, Shimadzu) of the thermal spray


D

coating layer was measured more 10 times with a 500 g load and a dwell time of 10 sec and
TE

their average values were determined.


P

3. Results and discussion


CE

Fig. 2 shows the cross section and EDS analysis results of the Inconel 625 coating. In Fig.
AC

2 (a), the deposited thickness of the Inconel 625 coating was around 220 ㎛. The range of

coating porosity including crack, pore, and the interfacial defect was measured at 6-8%. Many

pores and lamella structures resulting from the nature of thermal spray coating were clearly

observed. High temperatures and velocities of the fully melted particle usually form the

significant droplet deformation on impact at a surface, producing thin layers or lamella, often

called “splats” that adhere to the substrate surface. Solidified droplets build up rapidly, as a

continuous stream of fully melted particles impact to form continuous rapidly solidified

5
ACCEPTED MANUSCRIPT
layers. However, the sprayed particles from the nozzle actually reach the substrate in fully

melted, semi-melted, and unmelted conditions because the use of wires as a feedstock

material produces different size particles by the nonuniform heating and unpredictable drag

forces. If the particles are not fully melted or do not have sufficiently high velocity until the

collision with the substrate, the particles cannot fully fill the void in the coating and pores are

formed. Thus, the formation of pores is usually closely associated with large unmelted

PT
particles. For this reason, a relatively broad range of micro-Vickers surface hardness was

observed about 350-450 HV due to the rough surface morphology resulting from the

RI
irregularly deposited lamella structures and pore defects. Their average value was calculated

SC
as about 420 HV. Fig. 2 (b) presents the EDS spectrum of the area indicated in Fig. 2 (a).

High peaks of Ni, Cr, and Mo as main components of an Inconel 625 wire were observed.
NU
According to the studies by other researchers, Inconel 625 coating showed the Cr2O3 phase
MA

that was not detected in a feedstock materials such as powder, rod, etc. [10, 11]. The same

result was confirmed by the EDS analysis (Fig. 3) in this study.


D

Fig. 3 (a) exhibits the SEM image of a typical coating layer and Fig. 3 (b)-(f) displays the
TE

elemental concentration maps of Ni, Mo, Cr, O, and Nb for this area, respectively. In Fig. 3

(a), the coating layer largely consists of two areas: unmelted particles (U) and lamella
P

structures (L). The concentrations of Cr, Nb, and O were very high in many dark inclusions
CE

and grain boundaries of lamella structures, whereas those of Ni and Mo were relatively low.
AC

This means that Cr and Nb were oxidized and separated from the substrate during the high

temperature coating spray process [10]. Thus, oxides are formed mainly around the grain

boundaries and pore defects. At grain boundaries [7], Cr as an alloy element is preferentially

oxidized in the fully melted area where mass transportation is the fastest during heating the

wire particles. Therefore, Cr2O3 is formed on the particle surface, and the other Cr-depleted

droplets are sequentially solidified again. Furthermore, in the case of pores, air molecules are

6
ACCEPTED MANUSCRIPT
isolated, and pores are formed between unmelted or semi-melted particles that were deposited

first and splats of high temperature which are deposited later, thus facilitating oxidation.

Fig. 4 shows the surface morphology of Inconel 625 coating after applying various sealing

treatments by SEM. In Fig. 4 (a)-(b), Inconel 625 coating shows very rough surface

morphology including open pores. This was caused by the formation of surface roughness of

substrate to enhance the mechanical bonding strength before thermal spray coating work as

PT
shown in Fig. 2 (a) and the nature of spray coating that melted particles are consecutively

deposited at a high velocity. In Fig. 4 (c)-(d), Zinc sealing formed a very smooth surface, and

RI
the pores were locally observed. In an image at high magnifications, the particle size was

SC
smaller than 10 ㎛, and zinc particles with irregular shapes were observed. On the other hand,

the surface roughness of Hybrid sealing in Fig. 4 (e)-(f) and Ceramic sealing in Fig. 4 (g)-(h)
NU
was greatly alleviated compared to the as-sprayed Inconel 625 coating due to sealing
MA

treatment. However, micro-crack defects were observed on their sealed surface. In particular,

Hybrid sealing formed much more micro-cracks than that of Ceramic sealing, and the
D

micro-cracks were connected each other.


TE

Fig. 5 represents the results of potential measurement for 36,000 sec in seawater after

applying various sealing treatments to the Inconel 625 coating. In the case of as-sprayed
P
CE

Inconel 625 coating, a noble potential of -0.05 V/Ag|AgCl|KCl saturated in the beginning of

immersion sharply dropped to about -0.5 V/Ag|AgCl|KCl saturated after about 5,000 sec. The
AC

reason for this seems to be the formation of a mixed potential with the substrate which shows

a relatively active potential because seawater easily was penetrated into the substrate through

the defects of the coating layer such as pore and crack observed in Fig. 2 (a) and Fig. 4

(a)-(b). In general, the effect of porosity on corrosion resistance is very small because the

high-quality Inconel 625 coating by HVOF technique forms less than 1% porosity [11]. In this

study, the Inconel 625 coating layer, however, was produced by arc thermal spray technique

and has a relatively large porosity of 6-8%, and this led to the above results. After this period,

7
ACCEPTED MANUSCRIPT
the potential slightly decreased until the end of the experiment when it was measured at -0.57

V/Ag|AgCl|KCl saturated. Zinc sealing maintained a potential of about -0.9 V/Ag|AgCl|KCl

saturated until about 5,000 sec of immersion. After this period, the potential dropped to

approximately -1.0 V/Ag|AgCl|KCl saturated at around 15,000 sec and presented a stable

potential until the experiment end. It is believed that formed ZnO oxide film in the air was

destroyed by Cl- ion in seawater [20]. At the same time, the effective reaction area of active

PT
zinc particles increased as seawater infiltrated through the pores and the gap among zinc

particles observed in Fig. 4 (c)-(d). Nevertheless, anticorrosive effects by the sacrificial anode

RI
can be expected because, after 15,000 sec of immersion, Zinc sealing stably maintains a

SC
potential that is more active about -0.45 V/Ag|AgCl|KCl saturated than the as-received

coating and more active than -0.85 V (vs. SCE) which is the protective potential of the steel
NU
substrate [21-23]. During this period, zinc oxide (Zn1+xO) were formed at the solution and
MA

coating interface and progressed towards the substrate with increasing the immersion

duration [21]. On the other hand, Hybrid and Ceramic sealing formed noble potentials
D

throughout the experiment period, indicating improved corrosion resistance. In particular,


TE

Ceramic sealing continuously maintained a stable potential of around -0.15 V/Ag|AgCl|KCl

saturated during the immersion period. Even though micro-crack defects were observed on the
P
CE

surface in Fig. 4 (g)-(h), their effect is very small because the number is small and a stable

corrosion potential was maintained during the immersion time. On the other hand, Hybrid
AC

sealing exhibited a gradually decreasing tendency of the potential as well as unstable potential

variations with immersion time. This seems to be that seawater infiltrated into the coating

through many micro-cracks on the surface as observed in Fig. 4 (e)-(f).

Fig. 6 depicts the anodic polarization curves of Inconel 625 coating with sealing treatment.

The current density rapidly increased in general with no passive state section along with the

increasing potential. Throughout the experiment, the quantity of current density with potential

change was in the order of Ceramic < Hybrid < Inconel 625 coating < Zinc. Consequently,

8
ACCEPTED MANUSCRIPT
corrosion resistance was improved when Ceramic and Hybrid sealing were applied to the

Inconel 625 coating. These different trends of anodic polarization curves can be partially

inferred by observing the surface morphologies before and after the experiment.

The surface observations after anodic polarization experiments of the Inconel 625 coating

with sealing treatment are given in Fig. 7 and Fig. 8. The surface morphology of Inconel 625

coating underwent a little change after the experiment as shown by comparing Fig. 4 (a) and

PT
Fig. 7 (a). However, local corrosion damage was observed on the surface after the anodic

polarization experiment in the high-magnification image of Fig. 7 (b). The reason for the

RI
occurrence of local corrosions on the surface of Inconel 625 coating seems to be the local

SC
formation of Cr depletion [1,11]. In Fig. 3, the formation of Cr2O3 oxides was concentrated

around the unmelted particles or in the intersplats where lamella structures are formed. In
NU
other words, the existence of Cr2O3 oxides indicates the occurrence of Cr depletion in some
MA

parts of the as-sprayed Inconel 625 coating because Cr is consumed by the oxidation reaction

while the coating is deposited. As a result, microstructure areas with various Cr contents exist
D

on the surface as well as inside the coating. Thus, galvanic cells were formed, and galvanic
TE

corrosion occurred first in the Cr depletion areas. Furthermore, local corrosion damages were

mostly observed as a micro-crack shape. This seems to be the effect of residual stress which
P

occurs while the melted particles are transformed, solidified, and quenched during the
CE

deposition [9,11]. The residual stress of the thermal spray coating layer is attributed to tensile
AC

stress due to the volumetric shrinkage during the rapid solidification of the deposited melted

droplets [24-26]. In other words, the residual stress is believed to have been released by

numerous cracks caused by the active dissolution reaction on the coating surface that contains

residual stress during the anodic polarization experiment. Hybrid sealing was partially

detached throughout the surface, and Inconel 625 coating was exposed, leading to corrosion

damage as shown in Fig. 7 (c)-(d). This was caused by formed micro-cracks on the surface

before the experiment. So, in Fig. 7 (c), small surface damages occurred along the

9
ACCEPTED MANUSCRIPT
micro-cracks. When the micro-cracks were interconnected as shown in Fig. 4 (f), the Hybrid

sealing was easily detached as a flat plate shape, generating greater damages as shown in Fig.

7 (d). Therefore, to achieve effective corrosion protection of the Hybrid sealing, the measures

to control the generation of micro-cracks must be previously taken. However, corrosion

damages of Ceramic sealing tended to occur at the protrusion (bright area) as shown in Fig. 4

(h) despite the existence of micro-cracks on the surface like Hybrid sealing. This result seems

PT
to be attributed to the nature of the inorganic ceramic sealing material used in this study.

Liquid Ceramic sealing infiltrates into the pores by capillary action, and promotes the

RI
diffusion of sealant and the homogenization of microstructure through post heat treatment

SC
[27]. Therefore, deep infiltration is more effective if the impregnation time is longer, the

sealant viscosity is lower, and the wetting angle is smaller [27]. Consequently, the sealing
NU
effect of the protrusion was lower because the sealant on the protrusion easily flows down
MA

onto the rough surface arising from the low viscosity and smaller wetting angle of Ceramic

sealing as shown in Fig. 4 (a), and infiltrates into the Inconel 625 coating. Zinc sealing
D

generated a large surface damage of a crater shape throughout the surface because the Zinc
TE

sealing was partially detached as shown in Fig. 8 (a). In Fig. 8 (b), the surface shape is clearly

divided by the corrosion damaged area and the white corrosion area. The hemispherical
P

surface damages were observed in the corrosion damaged area because the zinc particles
CE

were separated from the coating in Fig. 8 (c). On the other hand, white corrosion products
AC

were formed evenly on the flat surface surrounding the damaged areas. They were observed

as white cotton-shaped products in Fig. 8 (d) and acts as a barrier by being piled up on the

open pores. This phenomenon known as “white corrosion” is generated by the oxidation of

zinc [3, 23]. Generally, zinc particles are corroded first in the early stage and present the

sacrificial anode effect for the cathodic protection of the steel substrate. After that, the pores

are covered by zinc corrosion products resulting from a white corrosion phenomenon, and the

cathodic protection is terminated. Instead of the cathodic protection, barrier-type protection is

10
ACCEPTED MANUSCRIPT
achieved by compact zinc corrosion products [21]. However, in this study, the local corrosion

damage occurred on the Zinc sealing layer and little white corrosion products were observed

in their surface damage area. This is probably due to the effect of the excessive dissolution

reaction of the Zinc sealing layer caused by the anodic polarization. Hence, the weaker part of

the bonding force between the particles is considered to be preferentially damaged before the

compact white corrosion products are formed on the Zinc sealing layer.

PT
Fig. 9 shows 3D analysis of the surface after anodic polarization experiments of the Inconel

625 coating with sealing treatment. Inconel 625 coating and Ceramic sealing which had less

RI
corrosion damage presented almost no changes in the surface roughness before and after the

SC
experiments, indicating the same tendency as the surface observations in Fig. 4 and Fig. 7. On

the other hand, the surface roughness difference before and after the anodic polarization
NU
experiment was calculated as 41 ㎛ for Zinc sealing and 54 ㎛ for Hybrid sealing, but the
MA

surface roughness of Hybrid sealing (149 ㎛) was significantly larger than that of Zinc

sealing (106 ㎛) after the anodic polarization experiment. This is because the surface
D

conditions before the anodic polarization experiment were very different each other. As
TE

shown in Fig. 4, Zinc sealing was uniformly applied at a thickness of about 80 ㎛, whereas
P

Hybrid and Ceramic sealing were thinly coated about 20 ㎛ and had the surface shape of
CE

Inconel 625 coating. Hence, the surface roughness of Zinc sealing (52 ㎛) was measured to
AC

be significantly smaller than that of the hybrid sealing (108 ㎛) before the anodic polarization

experiment. Consequently, Zinc sealing showed larger surface damage than Hybrid sealing.

Moreover, this is the same tendency as the results of the polarization curves and SEM analysis

related to the anodic polarization experiments.

Fig. 10 presents the polarization curves for the Tafel analysis of the Inconel 625 coating

with sealing treatment. The results of Tafel analysis are outlined in Table III. Due to the

nature of the active zinc, Zinc sealing showed the smallest corrosion potential of -0.91 V and

11
ACCEPTED MANUSCRIPT
the largest corrosion current density of 2.33 x 10-4 A/cm2. On the other hand, Inconel 625

coating presented a corrosion potential and a corrosion current density of -0.27 V and 1.18 x

10-5 A/cm2, respectively, indicating better corrosion resistance than that of Zinc sealing. The

corrosion resistance of Inconel 625 coating is most greatly affected by the porosity of coating

and the galvanic corrosion resulting from the local distribution of Cr depletion areas

[1,7,9-12]. Therefore, the corrosion resistance of Hybrid and Ceramic sealing was greatly

PT
improved by the role as a barrier of the sealing that fundamentally blocked the defects of

Inconel 625 coating. This can be quantified by calculating the sealing efficiency of

RI
Hybrid and Ceramic sealing using the following equation (1) [28-30]:

SC
(1)
NU
Where in is the corrosion current density after sealing treatment, and is the
MA

corrosion current density before sealing treatment. The effective application of sealing

treatment can be confirmed because the sealing efficiencies of Hybrid and Ceramic sealing by
D

the above equation were considerably high values of approximately 94.9% and 99.1%,
TE

respectively. In other words, this is assumed that most defects such as open pores and cracks

in the Inconel 625 coating were effectively blocked by Hybrid and Ceramic sealing.
P
CE

Consequently, the most effective corrosion protection performance can be expected when

Ceramic sealing is applied to the Inconel 625 coating considering the sealing treatment
AC

conditions in Fig. 4 (e)-(h).

4. Conclusion

This study aimed to investigate the corrosion behaviors of the arc thermally sprayed

Inconel 625 coating with sealing treatment through various electrochemical experiments in

natural seawater solution.

12
ACCEPTED MANUSCRIPT
In the case of the arc thermally sprayed Inconel 625 coating, the porosity and

micro-Vickers hardness were analyzed at 6-8% and around 420 HV, respectively.

Furthermore, Cr depletion areas were observed due to the formation of Cr oxides around the

unmelted particles and in the intersplat boundaries. Therefore, Cr depletion is believed to be a

major cause that degraded corrosion resistance by directly affecting the coating in the

seawater environment.

PT
All sealed Inconel 625 coatings performed well preventing the corrosion of the substrate by

acting as a barrier or a sacrificial anode against the corrosive natural seawater solution.

RI
Zinc sealing can expect the effect of corrosion protection by the sacrificial anode

SC
characteristics because it maintained a stable corrosion potential which was about -0.45

V/Ag|AgCl|KCl saturated lower than that of Inconel 625 coating. However, Zinc sealing
NU
generated the greatest surface damage due to local corrosion damage tendency. This is
MA

presumably because the excessive dissolution reaction is induced by anodic polarization on

the Zinc sealed coating and the local area of the weakly cohesive coating layer is detached
D

before the formation of compact white corrosion products acting as a barrier.


TE

Corrosion resistance of Hybrid and Ceramic sealing was significantly improved by

effective blocking the defects of the Inconel 625 coating. However, numerous micro-cracks of
P

Hybrid sealing on the surface were contributed to degrading corrosion resistance. As a result
CE

of various electrochemical experiments in this study, it is considered that Ceramic sealing has
AC

the best corrosion resistance due to the high sealing efficiency of 99.1% and smaller surface

corrosion damage tendency than those of others.

However, Zinc sealing is necessary to evaluate the corrosion resistance through the

immersion experiment for a long term similar to the actual corrosion environment in further

work because its coating has been confirmed to form compact white corrosion products with

anticorrosive function. On the other hand, Hybrid sealing is expected to produce a high

13
ACCEPTED MANUSCRIPT
quality sealed coating if a study is conducted to prevent the formation of crack defects on the

surface.

Acknowledgments

This research was a part of the project titled 'Construction of eco-friendly Al ship with

painting, and maintenance/repairment free', funded by the Ministry of Oceans and Fisheries,

PT
Korea.

RI
References

[1]
SC
D.A. Walsh, L.E. Li, M.S. Bakare, K.T. Voisey, Visualisation of the local electrochemical
NU
activity of thermal sprayed anti-corrosion coatings using scanning electrochemical
microscopy, Electrochim. Acta 54 (2009) 4647-4654.

[2] A. Niaz, S.U. Khan, A comprehensive pitting study of high velocity oxygen fuel Inconel
MA

625 coating by using electrochemical testing techniques, J. Mater. Eng. Perform. 25 (2016)
280-289.

[3] H.Y. Li, J.Y. Duan, D.D. Wei, Comparison on corrosion behaviour of arc sprayed and
D

zinc-rich coatings, Surf. Coat. Technol. 235 (2013) 259-266.


TE

[4] Q. Jiang, Q. Miao, F. Tong, Y. Xu, B.L. Ren, Z.M. Liu, Z.J. Yao, Electrochemical
corrosion behavior of arc sprayed Al-Zn-Si-RE coatings on mild steel in 3.5% NaCl
solution, Trans. Nonferrous Met. Soc. China 24 (2014) 2713-2722.
P

[5] W.M. Zhao, Y. Wang, C. Liu, L.X. Dong, H.H. Yu, H. Ai, Erosion-corrosion of thermally
CE

sprayed coatings in simulated splash zone, Surf. Coat. Technol. 205 (2010) 2267-2272.

[6] S.J. Kim, S.J. Lee, I.J. Kim, S.K. Kim, M.S. Han, S.K. Jang, Cavitation and
AC

electrochemical characteristics of thermal spray coating with sealing material, Trans.


Nonferrous Met. Soc. China 23 (2013) 1002-1010.

[7] D. Zhang, S.J. Harris, D.G. McCartney, Microstructure formation and corrosion behaviour
in HVOF-sprayed Inconel 625 coatings, Mater. Sci. Eng. A 344 (2003) 45-56.

[8] R.P. Krepski, Thermal Spray Coating Applications in the Chemical Process Industries,
MTI Publication No 42, NACE International, Nicholasville, 1993.

[9] F. Azarmi, H.R. Salimijazi, Grain growth and pore elimination in Inconel 625 deposited by
APS, Surf. Coat. Technol. 268 (2015) 3-6.

[10] A.A. Boudi, M.S.J. Hashmi, B.S. Yilbas, ESEM evaluation of Inconel-625 thermal spray
coating (HVOF) onto stainless steel and carbon steel post brine exposure after tensile tests,
J. Mater. Process. Technol. 173 (2006) 44-52.
14
ACCEPTED MANUSCRIPT
[11] N. Ahmed, M.S. Bakare, D.G. McCartney, K.T. Voisey, The effects of microstructural
features on the performance gap in corrosion resistance between bulk and HVOF sprayed
Inconel 625, Surf. Coat. Technol. 204 (2010) 2294-2301.

[12] Z. Liu, J. Cabrero, S. Niang, Z.Y. Al-Tah, Improving corrosion and wear performance of
HVOF-sprayed Inconel 625 and WC-Inconel 625 coatings by high power diode laser
treatments, Surf. Coat. Technol. 201 (2007) 7149-7158.

[13] T.C. Chen, C.C. Chou, T.Y. Yung, K.C. Tsai, J.Y. Huang, Wear behavior of thermally
sprayed Zn/15Al, Al and Inconel 625 coatings on carbon steel, Surf. Coat. Technol. 303
(2016) 78-85.

R. Knight, R.W. Smith, Z. Xiao, T.T. Hoffman, in: C.C. Berndt, Thermal Spray

PT
[14]
Industrial Applications, S. Sampath (Eds.), ASM International, Ohio, 1994.

[15] A. Neville, J.M. Perry, T. Hodgkiess, H.P. Chau, Wrought and high-velocity oxyfuel

RI
sprayed Inconel 625-examination of corrosion aspects, Proc. Instn. Mech. Engrs. 214
(2000) 41-48.

SC
[16] A. Neville, T. Hodgkiess, Towards novel ceramic base coatings for corrosive wear
applications, Br. Corros. J. 34 (1999) 262-266.
NU
[17] J. Tuominen, P. Vuoristo, T. Mäntylä, S. Ahmaniemi, J. Vihinen, P.H. Andersson,
Corrosion behavior of HVOF-sprayed and Nd-YAG laser-remelted high-chromium,
nickel-chromium coatings, J. Thermal Spray Tech. 11 (2002) 233-243.
MA

[18] I. Gedzevicius, A.V. Valiulis, Analysis of wire arc spraying process variables on
coatings properties, J. Mater. Process. Technol. 175 (2006) 206-211.
D

[19] V. Higuera, F. Belzunce, A. Carriles, S. Poveda, Influence of the thermal-spray


procedure on the properties of a nickel-chromium coating, J. Mater. Sci. 37 (2002)
TE

649-654.

[20]G.A. El-Mahdy, A. Nishikata, T. Tsuru, Electrochemical corrosion monitoring of


P

galvanized steel under cyclic wet-dry conditions, Corros. Sci. 42 (2000) 183-194.
CE

[21]H. Marchebois, C. Savall, J. Bernard, S. Touzain, Electrochmical behavior of zinc-rich


powder coatings in artificial sea water, Electrochim. Acta 49 (2004) 2945-2954.
AC

[22]C.M. Abreu, M. Izquierdo, M. Keddam, X.R. Novoa, H. Takenouti, Electrochemical


behaviour of zinc-rich epoxy paints in 3% NaCl solution, Electrochim. Acta 41 (1996)
2405-2415.

[23]A. Meroufel, S. Touzain, EIS characterisation of new zinc-rich powder coatings, Prog.
Org. Coat. 59 (2007) 197-205.

[24]K.H. Baik, J.H. Kim, B.G. Seong, Spray-formed tooling process by arc spraying, Trans.
Mater. Process. 14 (2005) 595-600.

[25] T. Rayment, S. Hoile, P.S. Grant, Phase transformation and control of residual stresses in
thick spray formed steel shells, Metall. Mater. Trans. B 35B (2004) 1113-1122.

[26] D.A. Jones, S.R. Duncan, T. Rayment, P.S. Grant, Control of temperature profile for a
spray deposition process, IEEE Trans. Control. Syst. Technol. 11 (2003) 656-667.
15
ACCEPTED MANUSCRIPT
[27] L. Pawlowski, The Science and Engineering of Thermal Spray Coatings, second ed.,
John Wiley & Sons Ltd, West Sussex, 2008.

[28] Z. Liu, D. Yan, Y. Dong, Y. Yang, Z. Chu, Z. Zhang, The effect of modified epoxy
sealing on the electrochemical corrosion behaviour of reactive plasma-sprayed TiN
coatings, Corros. Sci. 75 (2013) 220-227.

[29] Y.J. Yu, J.G. Kim, S.H. Cho, Plasma-polymerized toluene films for corrosion inhibition
in microelectronic devices, Surf. Coat. Technol. 162 (2003) 161-166.

[30]Y.H. Yoo, D.P. Le, J.G. Kim, Corrosion behavior of TiN, TiAlN, TiAlSiN thin films
deposited on tool steel in the 3.5 wt.% NaCl solution, Thin Solid Films 516 (2008)
3544-3548.

PT
RI
SC
NU
MA
D
P TE
CE
AC

16
ACCEPTED MANUSCRIPT
Fig. 1 (a) the structure of the main agent, (b) the structure of the harder

Fig. 2 SEM morphology and EDS analysis of the Inconel 625 coating. (a) cross sectional

morphology, (b) EDS spectrum of area in (a)

Fig. 3 SEM micrograph of the Inconel 625 coating and corrosponding EDS mapping of Ni,

Mo, Cr, O, and Nb.

PT
Fig. 4 SEM morphologies of the Inconel 625 coating with sealing treatment. (a)-(b)

as-sprayed, (c)-(d) Zinc sealing, (e)-(f) Hybrid sealing, (g)-(h) Ceramic sealing

RI
SC
Fig. 5 Corrosion potential measurements of the Inconel 625 coating with sealing treatment.
NU
Fig. 6 Anodic polarization curves of the Inconel 625 coating with sealing treatment.

Fig. 7 SEM morphologies of the inconel 625 coating with sealing treatment after anodic
MA

polarization experiments. (a)-(b) as-sprayed, (c)-(d) Hybrid sealing, (e)-(f) Ceramic sealing
D

Fig. 8 SEM morphologies of the inconel 625 coating with Zinc sealing treatment after anodic
TE

polarization experiments. (a) low magnification showing the local corrosion damage, (b)

boundary area between corrosrion damaged area and white corrosion area, (c) corrosion
P

damaged area, (d) white corrosion area


CE

Fig. 9 3D analysis of the Inconel 625 coating with sealing treatment and after anodic
AC

polarization experiments.

Fig. 10 Tafel analysis of the Inconel 625 coating with sealing treatment.

17
ACCEPTED MANUSCRIPT
Table I Arc thermal spraying parameters

No Variable parameter Value

1 Compressed air (bar) 6.5-7.0

2 Output voltage (V) 30

3 Output current (A) 150

PT
4 Spray distance (mm) 200

5 Spray angle (°) 90

RI
SC
NU
MA
D
P TE
CE
AC

18
ACCEPTED MANUSCRIPT
Table II Sealing conditions of Inconel 625 coating

Order Work Zinc Ceramic Hybrid

1 1st sealing About 40 ㎛ About 10 ㎛ About 10 ㎛


Atmospheric
2 Drying 60℃/1 h 60℃/1 h
temperature/24 h
3 2nd sealing About 40 ㎛ About 10 ㎛ About 10 ㎛
Atmospheric
4 Drying 60℃/1 h 60℃/1 h
temperature/24 h

PT
Thickness
About 300 ㎛ About 240 ㎛ About 240 ㎛
(Inconel 625 coating + sealing)

RI
SC
NU
MA
D
P TE
CE
AC

19
ACCEPTED MANUSCRIPT
Table III Tafel analysis results of the Inconel 625 coating with sealing treatment.

As-sprayed Zinc Hybrid Ceramic

Corrosion potential (V) -0.27 -0.91 -0.21 -0.16


Corrosion current
1.18 x 10-5 2.33 x 10-4 6.01 x 10-7 1.07 x 10-7
density (A/cm2)

PT
RI
SC
NU
MA
D
P TE
CE
AC

20
ACCEPTED MANUSCRIPT
O
O
O
O

O O

OMe OMe Si
Si OMe
OMe
Si
O OH
OMe O
O HO
HO Si O Si OH
O O Si Si O Si
Si O O O
O O Si OMe
OMe OO O O O
O O O O Si OH Si
OO Si
O
Si O Si
O Si O O O Si O O Si O
OMe O
O HO Si
O Si O O O Si OMe
O Si Si O Si O
O
Si O Si O OH O Si Si O Si
HO O O O O Si O OH
O O Si HO Si O O O
O O O Si
Si O Si O
O Si OH O
HO O O Si O Si O
O Si OH
Si O O Si HO O O
Si Si O O Si
O OH Si
HO OH OH HO
OH O O
OH O O
Si O Si O Si
HO O Si Si
O OMe
Si O O OMe HO OH
O OO OH OH H O OH
O Si Si O Si
HO Si O Si O O
O Si O OO
Si
O
O O
O Si
HO Si O Si
O OMe O O Si
O Si Si O Si O O O
OO OH Si O O
O Si O OH + Si
O Si
Si O OO O
HO Si O O
HO Si
O Si O O O O Si O
O O Si O OMe OMe O
O HO Si
O Si O O O Si O
Si
O O Si Si O Si O
Si O Si O
O Si OH O Si O OH O O
Si Si OMe
HO O O HO Si O O O O O
O Si
OH
Si O O Si O O Si HO Si Si
O O
O
Si O OMe O O O Si
HO OH O
Si
Si O Si O
O Si OH O
O O O Si O

PT
OH O Si O Si
OMe Si O O Si O O O
Si O
O Si O O Si
HO Si
O HO OH Si
Si O
OMe OMe
OMe O
OMe
Si Si
OMe
OMe O
O
O

RI
O
O O

SC
(a)

OR1
NU
R OR1
R NH2 + OR1 Si OR1 N
H Si OR1
OR1
MA

NH
R
(R: alkyl, aminoalkyl / R1: Methyl, Ethyl)
D

(b)
TE

Fig. 1
P
CE
AC

21
ACCEPTED MANUSCRIPT

Element wt. % at. %


(a) Crack (b) Ni 47.29 25.20
Cr 14.64 8.81
Mo 7.94 2.59
O 11.80 23.07
Nb 2.89 0.97
C 14.92 38.86
Al 0.32 0.38
Ti 0.19 0.12

Pores
Pore
Interfacial defect
Substrate

PT
Fig. 2

RI
SC
NU
MA
D
P TE
CE
AC

22
ACCEPTED MANUSCRIPT

(a) U (b) Ni (c) Mo


U
L
L
U 5um

(d) Cr (e) O (f) Nb

PT
RI
Fig. 3

SC
NU
MA
D
P TE
CE
AC

23
ACCEPTED MANUSCRIPT

(a) (b)

Inconel
625

500um 50um

(c) (d)

PT
Pores
Zinc

RI
SC
500um 10um

(e) (f)
NU
MA

Hybrid

500um 100um
D
TE

(g) (h)
P

Ceramic
CE

500um 100um
AC

Fig. 4

24
ACCEPTED MANUSCRIPT

0.4

0.2 As-sprayed Ceramic


Hybrid Zinc

Potential, E/V vs. Ag/AgCl


0.0

-0.2

-0.4

-0.6

PT
-0.8

-1.0

RI
-1.2
0 10000 20000 30000 40000

SC
Time, sec

Fig. 5
NU
MA
D
P TE
CE
AC

25
ACCEPTED MANUSCRIPT

3.5

3.0
As-sprayed
Potential, E/V vs. Ag/AgCl
2.5 Ceramic
Hybrid
2.0 Zinc
1.5

1.0

0.5

PT
0.0

-0.5

RI
-1.0

-1.5

SC
-9 -8 -7 -6 -5 -4 -3 -2 -1 0
10 10 10 10 10 10 10 10 10 10
2
Current density, A/cm
NU
Fig. 6
MA
D
P TE
CE
AC

26
ACCEPTED MANUSCRIPT

(a) (b)

Inconel
625

500um 50um

(c) (d)

PT
Hybrid

RI
SC
500um 100um

(e) (f)
NU
MA

Ceramic

500um 100um
D
TE

Fig. 7
P
CE
AC

27
ACCEPTED MANUSCRIPT

(a) (b)

500um 50um

(c) (d)

PT
RI
SC
10um 10um

Fig. 8
NU
MA
D
P TE
CE
AC

28
ACCEPTED MANUSCRIPT

Before After

129um 135um

Inconel 625

52um 106um

PT
Zinc

RI
108um
SC 149um
NU
Hybrid
MA
D

117um 116um
TE

Ceramic
P
CE

Fig. 9
AC

29
ACCEPTED MANUSCRIPT
0.3

0.0

Potential, E/V vs. Ag/AgCl


-0.3

-0.6

As-sprayed
Ceramic

PT
-0.9 Hybrid
Zinc

RI
-1.2
-10 -9 -8 -7 -6 -5 -4 -3 -2
10 10 10 10 10 10 10 10 10

SC
Current density, A/cm
Fig. 10 NU
MA
D
P TE
CE
AC

30
ACCEPTED MANUSCRIPT
Highlights

 Inconel 625 coating deteriorated corrosion resistance due to the effects of its p
orosity and Cr depletion.

 Sealing with zinc powder, inorganic ceramic, and organic-inorganic composite


ceramic were performed.

 Corrosion behavior was investigated through various electrochemical experiment


s.

 Inorganic ceramic was found to have the best corrosion protection performance

PT
.

RI
SC
NU
MA
D
P TE
CE
AC

31

You might also like