0% found this document useful (0 votes)
6K views3 pages

TC544 TC244 TC344 PDF

Uploaded by

Gaurav Agrawal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6K views3 pages

TC544 TC244 TC344 PDF

Uploaded by

Gaurav Agrawal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

TC544A/TC244AX/TC344AX Economic Temperature Controller

Features:
! Dual Display, 4 digit, 7 segment LED
! TC / RTD Input
! PID, ON/OFF Control
! Two Setpoints
o
! C / oF Selectable
! Field selectable Control Output (Relay or SSR)
! Auxiliary Output : Relay / SSR
! Easy to use

Size: 48mm x 48mm, 72mm x 72mm, 96mm x 96mm


48x48 72x72 96x96 Certifications:
®

C US

Technical Specifications Functional Specifications:

Display Heat-cool

Digits 4 digit 7 Segment LED, Dual display Control Action PID (with auto-tuning)
TC544 : Height of Upper Display : 0.3785" Proportional Band-Cool 0.0 to 400.0o
Height of Lower Display : 0.2720" Cycle Time-Cool 0.1 to 99.9 sec
TC244 : Height of Upper Display : 0.5385"
Dead Band Programmable from setpoint low limit
Height of Lower Display : 0.3755"
to setpoint high limit.
TC344 : Height of Upper Display : 0.5510"
Height of Lower Display : 0.3830" Settings for Alarm Output
LED Indication Relay ON, Tune, Soak Time Modes Deviation, Absolute
Hysteresis 0.1 to 99.9o
Input Specifications
Supply Voltage
Inputs Thermocouple (J,K,T,R,S) / RTD (Pt100)
Sampling time 250 ms Supply Voltage 85 to 270V AC/DC (50 / 60Hz)
OPTIONAL - 24V AC/DC, ±10%
Input Filter (FTC) 0.2 to 10.0sec
Power Consumption 6VA max @ 230V AC
Resolution 0.1/1o for TC/RTD inputs
(fixed 1o for R & S type TC input)
Temperature Unit o
C / oF selectable Environmental Specifications
Indication Accuracy For J, K & T inputs: 0.25% of F.S. ±1o Temperature Operating: 0 to 50oC (32 to 122oF)
For R & S inputs: 0.5% of F.S. ±2o Storage: -20 to 75oC (-4 to 167oF)
(20 min of warm up time for TC inputs)
Humidity (non-condensing) 95% RH
For RTD inputs: 0.1% of F.S. ±1o
(F.S. = Full Scale) Weight TC544 : 142 gms
TC244 : 190 gms
TC344 : 252 gms
Output Specifications
Protection Level IP65 for faceplate
Control 1
Contact Rating 5A @ 250V AC / 30V DC, resistive Compliance
SSR Drive (Voltage Pulse) 12V DC ±10%, 50mA IEC/EN 61326 (EMI/EMC)
Alarm 1 IEC/EN 61010 Revision3 2010 Edition (Safety)
Contact Rating 5A @ 230V AC / 30V DC, resistive UL 61010 Revision3 2010 Edition (Safety)

Functional Specifications:

Control Action 1) PID


2) ON-OFF
Proportional Band (P) 1.0 to 400.0o
Integral Time (I) 0 to 9999 sec
Derivative Time (D) 0 to 9999 sec
Cycle Time 0.1 to 99.9 sec
Hysteresis Width 0.1 to 99.9o
Manual Reset Value -19.9 to 19.9o

www.selec.com 1
TC544A/TC244AX/TC344AX Economic Temperature Controller

Dimensions Input Sensor Ranges


Panel Cutout
Resolution Ranges
A G
Sensor type 1 0.1
D o
B F C -150 to 850 -150 to 850
Pt100
o
F -238 to 1562 -199 to 999
E C o
C -199 to 750 -199 to 750
J
o
F -328 to 1382 -199 to 999
MODELS DIM A B C D E F G
o
C -199 to 1350 -199 to 999
TC544A 52 52 94 45 4 46 46 K
o
F -328 to 2462 -199 to 999
TC244AX 72 72 83.7 67 4.5 69 69
o
C -199 to 400 -199 to 400
TC344AX 96 96 73 90.5 5 92 92 T
o
F -328 to 750 -199 to 750
All dimensions are in mm
o
C 0 to 1750 N/A
R&S
o
Mounting Accessories (Supplied with units) F 32 to 3182 N/A

For TC544 : 48 X 48 Collar clamp ACL4802


For TC244/TC344 : Clamp side with screw assembled Terminal Connections

TC544A/TC544A-1 TC244AX TC344AX


TC+/RTD1 TC+/RTD1 TC+/RTD1
L (+) 1 8 L (+) 1 10
L (+) 1 11 6
N (-) N (-) 2 11
2 9 TC-/RTD2
N( ) 2 SSR1+ 7 TC-/RTD2
- NO2 3 12
TC /RTD2 3 10 NO2
RTD3
NO2 RTD3 4 13
3 + 8 COM2 4 11
- SSR2

RTD3 COM2 5 14
NC2 5 12 +
NC2

SSR
6 15
COM2 4 9
SSR1- NO1 NO1
6 13 7 16 +

SSR
NO1
5 12 10 COM1 7 14 COM1 8 17

-
COM1 NC1
NC1 9 18

Cable Size (AWG): 16-13 ; Stud Hole for Lug (inch): 0.137 ; Tightening Torque (Lb-inch): 7

Cable Size (mm2): 1.5-2.5 ; Stud Hole for Lug (mm): 3.5 ; Tightening Torque (N-m): 0.8

Ordering Information
This product is CE certified. Also available with UL marking against order. Please order as per the requirement.

Part No. Control Output Auxiliary Output Supply Voltage

TC544A Relay 12V DC SSR Relay 85 - 270V AC/DC


TC544A-1 Relay 12V DC SSR 12V DC SSR 85 - 270V AC/DC
TC544A-24V Relay 12V DC SSR Relay 24V AC/DC
TC544A-1-24V Relay 12V DC SSR 12V DC SSR 24V AC/DC
TC244AX Relay 12V DC SSR Relay 85 - 270V AC/DC
TC244AX-24V Relay 12V DC SSR Relay 24V AC/DC
TC344AX Relay 12V DC SSR Relay 85 - 270V AC/DC
TC344AX-24V Relay 12V DC SSR Relay 24V AC/DC

www.selec.com 2
TC544A/TC244AX/TC344AX Economic Temperature Controller

UL approved part numbers

Part No. Control Output Auxiliary Output Supply Voltage Certification

TC544A-CU Relay 12V DC SSR Relay 85 - 270V AC/DC


®

C US

TC544A-1-CU Relay 12V DC SSR 12V DC SSR 85 - 270V AC/DC


®

C US

TC544A-24V-CU Relay 12V DC SSR Relay 24V AC/DC


®

C US

TC544A-1-24V-CU Relay 12V DC SSR 12V DC SSR 24V AC/DC


®

C US

TC244AX-CU Relay 12V DC SSR Relay 85 - 270V AC/DC


®

C US

TC244AX-24V-CU Relay 12V DC SSR Relay 24V AC/DC


®

C US

TC344AX-CU Relay 12V DC SSR Relay 85 - 270V AC/DC


®

C US

TC344AX-24V-CU Relay 12V DC SSR Relay 24V AC/DC


®

C US

Accessories ( Optional )
Standard SELEC accessories that can be used with this product.

Adapter plate
1) AP7248 : Plastic adapter plate, used to mount 1/16 DIN (cutout size 48 x 48)
Instrument into existing (72 x 72) cutout size.
2) AP9648 : Plastic adapter plate, used to mount 1/16 DIN (cutout size 48 x 48)
Instrument into existing (96 x 96) cutout size.
3) AP9672 : Plastic adapter plate, used to mount 72 x72mm size instrument
into existing (96 x 96) cutout size.
4) AP4896-4848-G-C : Plastic adapter plate, used to mount 1/16 DIN
(cutout size 48 x 48) Instrument into existing (48 x 96)
cutout size.

www.selec.com 3