RCC PRACTICE SET 04_ 20-09-2019
1) An RC short column with 300 mm x 300 mm
square cross section is made of M25 grade
concrete and has 4 members, 20 mm diameter
longitudinal bars of Fe415 steel. It is under the
action of concentric axial compressive load
Ignoring the reduction in the area of concrete
due to steel bars, the ultimate axial load carrying
capacity of the column will be kN.
[1403.63]
2) A square column of size 350 mm x 350 mm is
reinforced with 4 bars of 25 mm dia and four
bars of 16 mm dia each. The transverse
reinforcement that should be provided is
a) 5mm © @ 250 mm ¢/c spacing
b) 6 mm © @ 250 mm c/c spacing
c) 8mm ® @ 250 mm c/c spacing
d) 8 mm © @ 300 mm ¢/c spacing
3) The plan of a reinforced concrete column section,
and of distribution of strains along the column
depth at the ultimate limit stage are shown
below. The concrete is M20 grade and the stee!
is Fe250 grade. Also sketched below, for
convenience are the concrete compressive stress
block and the design stress strain curve for
Fe250 with all notations as per IS : 456. Ignore
the reduction in the concrete area due to the
embedded steel.
nas seson
0.416%
0070 me
2.204, on
Fionn
Doe Strain Profile Cos = 038 fx baw
wp
osm
Es-2x0"wra
ol ‘
‘The ultimate axial compression capacity of the
column is kN.
a) 965
©) 1255
b) 875
d) 1055
4) A circular helical column has a diameter of 450
mm, subjected to 2 working load 1500 kN.
Column has unsupported length of 3.5 m and is
effectively held in position at both ends not
restraint against rotation. Using limit state
method the % of steel provided to sustain the
load is [use M25, Fe415] [1.29]
5) A reinforced column ha effective length 3 m and
‘axial load carrying capacity of 2400 kN. The
dimension of the column is 350 mm x 450 mm.
350mm
as0mm |
Consider the following statements and select the
correct option
a) Minimum eccentricities criteria of design of
column satisfies in both x and y directions
b) Minimum eccentricities criteria of design of
column satisfies in x direction but not in the
y direction
c) Minimum eccentricities criteria of
design of column satisfies in y direction
but not in the x direction
d) Minimum eccentricities criteria of design of
column does not satisfies in both x and y
directions
6) In a RCC column, the diameter of the
longitudinal bars used is 25 mm. the column is
circular in x-section whose mean dia of 650 mm.
the minimum cover to concrete clear of
longitudinal bars should be
a) 50mm b) 40 mm
©) 25mm 4) 12.5 mm
7) Spiral reinforced concrete column's results in
a) Increased strength
b) Increased ductility
©) Decreased strength and increased ductility
d) Increased strength and increased
ductility
8) When the column is supported throughout ‘ts
length either by masonry wall or construction on
all sides, then its slenderness ratio is
a) Reasonably high b) Low
©) Infinite d) zero
9) A column (350 x 450) mm is reinforced with 4
ros of 20 mm and 2 nos of 24 mm diameter bars,
the pitch of transverse reinforcement using 8
mm diameter will be
a) 320mm
©) 384mm
b) 350 mm.
4) 450 mmRINCHTAR acc -Ps -04
10} A RC column under axial compression and uni-
axial bending has its neutral axis lying outside
the section, then stress strain diagram is: [D]
“a
J
@®)
©
11) A column Is required to carry a load 2000000 N
inclusive of its own weight. The column is a tied
column and can be considered as a short one
Size of the column so as to obtain the smallest
square column is mm, use concrete mix
grade M20. [352.45]
12)To construct a circular column of diameter 450
mm and 3 m unsupported length made of M20
concrete with 6-20 mm diameter steel bars of
Fed15 provided longitudinally. If limit state
method was used to design the column with a
partial factor of safety for load as 1.5, then the
maximum service axial load (in kN) that this
column can carry
a) 1781.39 kN
©) 1981.20 kN
b) 1187.59 kN
d) 1369.17 KN
13) If a square footing of 4 m size is designed to
support a square column of 400 mm size. The
effective depth of the footing is 400 mm. the safe
bearing pressure below the footing is 100 kPa
based on the ultimate loads. What is the nominal
shear stress for one way shear (kPa)
(350)
14) While designing for a steel column of Fe250
grade, a base plate resting on a concrete
pedestal of M20 grade, the bearing strength of
concrete is in N/mm?) in limit state
method of design as per 1S:456-2000 is
[9]
15) For the design of reinforced concrete footing, the
pressure distribution of soil beneath the footing
is assumed to be
8) Hyperbolic
©) Linear
b) Parabolic
d) none of these
3
[E>
Tp
;
16) A square column 500 mm x 500 mm carries an
axial load 1000 kN. The footing for the column
has dimensions of 2.75 m x 2.75 m. the safe
bearing capacity of the soil is 225 kN/me. The
factored maximum bending moment acts on the
footing is kNim [using LSM][345.17]
17) An REC rectangular footing of size 2m x 1m
having effective depth of 300 mm, size of
column is 230 x 230 mm. the line of action of the
vertical compressive load passes through
centroid of the footing as well as column. If the
magnitude of load is 450 kN punching shear
stress in the footing is
a) 0.2 N/mm?
©) 0.6 N/mm?
b) 0.4 N/mm?
4) 0.8 N/mm?
18)A steel column of size 600 mm x 600 mm is
resting on a square footing of size 3m x 3m and
a uniform depth of 420 mm. the permissible
bearing stress using the limit state method is
[use M20 grade concrete]
a) 18 MPa
) 22 MPa
b) 20 MPa
d) 24 MPa
19) The square footing of size 3 m is designed to
support @ square column of 300 mm size
Effective depth of footing is 500 mm. safe
bearing pressure below the footing Is 150 kPa at
ultimate conditions. The two way shear stress
developed will be MPa. [0.784]
20)A reinforced concrete square footing of side 2 m
and uniform effective depth of 250 mm is
provided for a 300 mm x 300 mm column. The
line of action of the vertical compressive load
passes through the centroid of footing as well as
column. If the magnitude of ultimate axial force
is 400 KN at its base then one way shear stress
acting in the footing is N/mm, (0.24)
21) Which one of the following statement is correct?
In 2 combined footing for two columns carrying
unequal loads, the maximum hogging moment
occurs at
1a) Inside the face of the heavier column
b) A section having maximum shear force
©) A section having minimum shear force
4) A section having zero shear force
22)A column of section (S00 x 500) mm and
subjected to a load of 2500 kN at service state
consider unit weight of the soil = 20 kN/m?
Angle of repose = 30°; Allowable bearing
capacity of the soll = 150 kN/m?
Concrete grade M20 and steel grade Fe415
The minimum depth of foundation will bem.
[0.833]
Aare) RINCHTAR CLASSES IM: 4917877554488
RINCHTAR _acc -Ps -04