Catalogo Bollitori Inglese 2017 - 2018 PDF
Catalogo Bollitori Inglese 2017 - 2018 PDF
C AT ALOGUE
2017 - 2018
Cordivari company has a proven industrial tradition and is now one of the most
important manufacturers in the heating and plumbing industry in Italy.
Founded in 1972 by Ercole Cordivari, the company is producing calorifiers, thermal
storage and heating components, solar thermal systems, compressed air receivers,
design radiators, chimney flues and food containers. Cordivari plants are situated on
an area of 280.000 square meters and employ more than 450 employees.
Thanks to its development strategies, all addressed to the new technologies and to the
training of new human resources, Cordivari is equipped with modern structures and
advanced production processes. All the products are designed and produced in Italy
and the technological, ergonomic and ecological choices allow to work respecting the
human being and its environment. UNI EN ISO 14001:2015 environment managing
systems and UNI EN ISO 9001 Quality system are perfectly integrated to grant and
ensure company’s main goals and values.
The highly qualified management, the constant research for innovative solutions
and the extremely customer-oriented company policy stand for the leading market
position and the exclusive know-how in the field of integrated heating systems that
the Cordivari group has acquired.
All this is the result of a continuous commitment to achieving Customer Satisfaction.
1
2
Technologies for Wellness
D evelopment, design and innovation studies are key points in Cordivari production process. Each proposed solution
conveys technical reliability, design, ergonomics, ease of use and installation. The continuous development of our product
offer, wants to witness the company’s attention to the market needs. Similarly, the research and development of new
solutions follows the trends of an efficiency and energy savings oriented market.
T he different phases of production are in perfect harmony with the best techniques for industrial automation, robotics
and advanced craftsmanship.
Every product undergoes several times during the production stages, a rigorous control, manual and visual.
C ordivari products meet the most important certifications, such as the PED (Pressure Equipment Directive) and the
Directive 2009/125/CE (ErP – eco-friendly planning regulations) in compliance with the cylinders and other pressure
vessels manufactured. All items for Domestic Hot Water storage are certified for drinkable water use in accordance with
the strictest Italian and foreign regulations (SSICA, Attestation ACS, DVGW W270, UBA, WRAS).
I n Cordivari quality care and attention to the environment has always been home. In fact we were the first company of
the heating sector to obtain the certification according to UNI EN ISO 9001 integrated with environmental management
certification UNI EN ISO 14001: 2015. This production philosophy, which is now a way of life for us, means reduction of
emissions and energy inefficiencies, waste reduction and recycling over 60% and allows us to operate in a sustainable
and environmentally friendly way, using clean energy from renewable sources, using only eco-friendly materials from raw
materials to packaging.
CERTIFICATIONS
PRODUCT CERTIFICATIONS
Dipartimento di Energia
Italian Stainless Steel 2014/68/UE ErP RELAB- Renewable Heating and Cooling LAB
CERTIFICATES OF CONFORMITY
DVGW W270
UBA KTW
on Polywarm® internal
coating
Internal treatment for food use D.H.W. Certification
Polywarm® in accordance with (Attestation de Conformité Water Regulation Advisory
D.M. nr. 174 del 06/04/2004 Sanitaire) granted by Scheme certificate
granted by SSICA Laboratory of CARSO – Laboratoire Santé
Parma - Italy. Environnement Hygiène De
Lyon about Polywarm® anti-
corrosion treatment
3
ICONS
S T O C K
AVA I L A B I L I T Y
grey
Domestic Hot Water production (D.H.W.) Heating Water Production STOCK AVAILABILITY
Grey highlighted products are available in stock and
can be dispatched in 1-5 working days.
Calorifiers with traditional boilers: Calorifiers with biomass boilers: Calorifiers with condensing boilers:
These products are designed for use with The selection of a calorifier while operating in Condensing boilers are highly efficient
conventional boilers which use water as a conjunction with a biomass boiler must take and ecologically friendly. They operate at
heating medium in a sealed or open expansion account of fact that excessively low return optimum performance when the flow water
circuit. The heat exchangers are designed to water temperatures could reduce the lifespan temperature is limited which results in the
handle high flow rates on the primary side to of the boiler. In addition, a calorifier with a return water temperature being as low as
ensure that the heat transfer will be efficient larger accumulation volume than normal possible. This will ensure that the latent heat
while at the same time avoiding excessively will be more suitable as it will act as a buffer is extracted out of the combustion products
low return water temperatures. which will be beneficial to the biomass boiler. which will maximise the efficiency of the
system.
Calorifiers with solar systems: Calorifiers with heat pumps: Calorifiers with steam boilers:
The heat exchange coil surface area is a Calorifiers operating in conjunction with air- The use of saturated steam as a heating
critical issue when interfacing solar thermal to-water or water-to-water heat pumps must medium to produce domestic hot water,
systems with calorifiers due to limited have extremely oversized heat exchange although little used in the housing sector,
is a solution which is still employed in
primary flow rates and temperatures. The surface areas to ensure that heat exchange industrial environments where the steam is
calorifier must also be capable of acting as a will take place even when there is a limited already in use for the manufacturing process.
buffer to harness the solar energy throughout difference in temperature between the Technically speaking, steam calorifiers
daylight hours. primary circuit and secondary stored water. are characterized by relatively small heat
This will maximise the COP (coefficiency of exchangers, as on one hand the steam gives
performance) of the heat pump. high heat exchange coefficients and on the
other hand the exchangers usually operate
with considerable differences in temperature Domestic hot water
between the primary and secondary circuits.
The use of steam demands a more stringent production (D.H.W.)
safety regeime than the use of low pressure
hot water systems as steam boilers,
depending on their capacity and design
pressures, are classified as higher risk and
therefore must comply with the European
Pressure Equipment Directive.
Calorifiers operating with more than one Calorifiers operating with renewable Calorifiers operating with electrical power
energy source energies Cordivari products designed for working with
The demand to heat a calorifier using more D.H.W. production system connected to electricity can be connected to A/C power
than one energy source, while at the same renewable energies, exploiting natural supply.
time keeping the various circuits separate, resources coming from air, water and ground. Combined with a renewable energy power
has become much more common in
recent times with the advent of renewable supply system (fotovoltaic, wind energy, and
technologies which usually need to be so on), it allows to have an environmental
backed-up with conventional boilers. In these friendly system.
cases, calorifiers with a number of heat
exchangers are used with the design ensuring
that excellent thermal stratification will be
achieved with minimal interference between
the various heat sources.
Central heating systems with one or more boilers which are Central heating systems with one or more boilers which are Heating systems with one or more sources hydraulically divided,
plumbed together and do not generate domestic hot water. plumbed together in conjunction with solar power which is with the exploitation of the solar power and without DHW
connected to either one or two coil type heat exchangers. production.
Domestic hot water is not generated in these tanks. These are heating systems powered by a biomass generator or
more generators that are hydraulically divided.
The preparation of the DHW is done without involving the hot
water storage tank.
+ + +
Combined central heating system and domestic hot water Combined central heating system and domestic hot water Combined central heating system and domestic hot water
production with one or more boilers which are plumbed together. production with one or more boilers which are plumbed together. production with one or more boilers which are plumbed together.
4
PRODUCT NEWS
NEW BOLLY ERP A CLASS
Bolly calorifiers with A energy efficiency class synthesize performance and efficiency being at the top of the energetic
class with excellent performances in DWH production end energy saving.
These tanks for DHW preparation are expressly conceived for installations and latest generation buildings and for
all those who wish to achieve the best performances both with any traditional or renewable energetic source or heat
generator. This new range of BOLLY A CLASS is available with one or two fixed heat exchangers with capacity from
200 up to 500lt.
The reliability and versatility are key aspects that always have distinguished the Bolly range and are now enhanced
by the lowest thermal dispersions envisioned by existing norm 2009/125/CE ErP Ecodesign, consolidating their lead
role in the market.
5
WELLNESS
and SAVING
Solutions for your Home
WATER TANKS
HIGH EFFICIENCY
RADIATORS
6
APPROVED
CERTIFIED QUALITY
CHOOSE SERENITY
Today, more than ever, who choose Cordivari products
choose to be peaceful!
By introducing the new Ecodesign ErP standards, we
choose to offer you guaranteed performances and CORDIVARI S.r.l.
Zona Industriale Pagliare – 64020 MORRO D’ORO (TE) Italia
reliability.
Tel. +39 085 80.40.1 r.a. - Fax UFF: COMM: +39 085 80.41.418 - Fax CENTR. +39 085 8041280
C.F. - P. IVA - REG. IMPRESE TE N. IT 00735570673 - R.E.A. TE N. 92310 – CAP. SOC. €.4.000.000,00 i.v.
www.cordivari.it – [email protected]
the result of this choice. As from 2015, the company is Z'K>DEdK ;hͿ E͘ ϴϭϰͬϮϬϭϯ >> KDD/^^/KE > Ϯ 'K^dK ϮϬϭϯ ZEd
DK>/d/WW>//KE>>/Zdd/sϮϬϬϵͬϭϮϱͬ>WZ>DEdKhZKWK>
KE^/'>/K /E DZ/dK >> ^W/&/, WZ > WZK'dd/KE KKDWd//> '>/
^ĐŽƉŽĚĞůůĂƉƌŽǀĂ
EϭϱϯϯϮ͗ϮϬϬϳϱ͘ϰ
ĞƚĞƌŵŝŶĂƌĞůĂĚŝƐƉĞƌƐŝŽŶĞƚĞƌŵŝĐĂŶĞůůĞĐŽŶĚŝnjŝŽŶŝƉƌĞǀŝƐƚĞĚĂůůĂ
ŶŽƌŵĂĂůĨŝŶĞĚŝĐĂƌĂƚƚĞƌŝnjnjĂƌĞŝůƉƌŽĚŽƚƚŽŽŐŐĞƚƚŽĚĞůůĂƉƌŽǀĂ
ŶĞůů͛ĂŵďŝƚŽĚĞůůĞĐůĂƐƐŝĞŶĞƌŐĞƚŝĐŚĞƉƌĞǀŝƐƚĞĚĂůZĞŐŽůĂŵĞŶƚŽh
the best solutions, in order to guarantee you reliability, savings and high results.
EXAMPLE OF LABEL FOR TANK WITH HEAT PUMP EXAMPLE OF LABEL FOR TANK/MULTI-HEAT ENERGY BUFFERS
A+ A+ A+
A A
Energy efficiency class B
Energy efficiency class
B
C C
D D
E E
F Sound power level F Heat Loss
L
2017 812/2013
2017 812/2013
7
EXTRA- BOLLY® CALORIFIERS
HYDRONIC
COLD/HOT WATER
INERTIAL TANKS
PRESSURE VESSEL
AIR
TECHNICAL SUPPORT
8
NEW
A PAGE 10
NEW
PAGE 100
PAGE 110
PAGE 140
NEW
PAGE 166
NEW
PAGE 222
NEW
PAGE 256
PAGE 268
PAGE 278
PAGE 284
PAGE 298
9
CALORIFIERS
10
11
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
EXTRA CALORIFIERS RANGE
DHW
production
Number of heat
exchangers / / / /
Energy source
Energy efficiency
C C C
class
12
EXTRA- BOLLY®
CALORIFIERS
ErP
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
EXTRA Vapore EXTRA Plus Piastraterm® VASO Inerziale
CYLINDERS - PUFFER
MULTIFUEL ENERGY
316L STAINLESS STEEL Extractable straight double spiral 316L STAINLESS STEEL
extractable copper finned braze-welded plate heat with blind flange plate
straight heat exchanger heat exchangers exchangers
/ / /
HYDRONIC
INERTIAL
TANKS
C C C C
WATER PRESSURE
- Polyurethane hard foam - Polyurethane hard foam - Polyurethane hard foam
- Polyurethane hard foam
TANKS
- Dismountable polyester fleece - Dismountable polyester fleece - Dismountable polyester fleece
Industrial installations/
Solar, biomass and Solar, biomass and Traditional, solar, biomass and
installations with steam
condensation installations condensation installations condensation installations
generators
TECHNICAL
SUPPORT
13
EXTRA1
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
POLYWARM®
S T O C K ENERGY
AVAILABILITY
EXTRA 1 WXB STAINLESS STEEL EFFICIENCY
CLASS
grey HEAT EXCHANGER
HARD FOAM SURFACE
ErP
HARD FOAM INSULATION
Model insulation
Art. Nr. [m2]
200 3072162360122 0,5 C
300 3072162360123 0,75 C
500 3072162360124 1 C
800 3072162360125 1,5 C
1000 3072162360126 2 C
1500 3072162360127 3 C
2000 3072162360128 4 C
www.cordivari.com/erp ENERGY
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
EXTRA 1 WXC STAINLESS STEEL EFFICIENCY
On line ErP label tool HEAT EXCHANGER
CLASS
DISMOUNTABLE SOFT FLEECE SURFACE
Model insulation ErP
Art. Nr. [m2]
SOFT FLEECE INSULATION
500 3072162360134 1 C
800 3072162360135 1,5 C
1000 3072162360136 2 C
1500 3072162360137 3 C
2000 3072162360138 4 C
2500 3072162360113 5
3000 3072162360109 6
4000 3072162360110 8
5000 3072162360112 10
14
EXTRA1
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
BOLLYTERM®
1500 ÷ 5000 6 bar to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
(14)
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
H17 (11)
(12) (13)
H16 (10)
CALORIFIERS FOR
H15 (9)
HEAT PUMP
Drain 1” 1/4 F.
1
For model 1000 connection 1”1/2 Gas F
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H6 (7) H5 (6)
Primary circuit outlet 1” Gas F.
H4 (5) H3 (4) 4
For models > 500 connection 2” Gas F
5 Heat exchanger flange
H2 (2) (3)
Primary circuit inlet 1” Gas F.
6
For models > 500 connection 2” Gas F
7 Connection for instrumentation 1/2" Gas F
H1(1)
0 8 Connection for magnesium anode 1" 1/4 Gas F
HYDRONIC
Connection for 2nd anode 1"1/4 Gas F (only for models
9
> 1500)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
12 Connection for instrumentation 1/2" Gas F
TANKS
gripps on the bottom which allow
14 Domestic hot water outlet
(7) (10) (12) the use of forklift when handling and
(8) (9) drain pipe already fitted. 15 Drain 1" Gas F (only for models > 1000 )
16 Heat exchanger air purge 3/8" Gas F
(4) (5) (6) (16)
WATER PRESSURE
TANKS
HARD FOAM INSULATION (WXB)
2-3
Model Volume Weight De H A H1 H2 H3 H4 H5 H6 H7 H15 H16 H17 5 14
11-13
[lt] [kg] [mm] Connections Gas F
200 191 52 550 1449 1550 85 325 360 410 460 520 650 // 1075 1185 Øe 300 1"1/4 1”1/4
300 292 65 650 1499 1634 85 350 385 435 485 545 735 // 1100 1210 Øe 300 1"1/4 1”1/4
COMPRESSED AIR
500 500 83 750 1800 1950 85 375 410 460 510 570 760 // 1329 1485 Øe 300 1"1/4 1”1/4
RECEIVERS
800 794 139 900 2135 2317 85 405 450 540 630 690 870 // 1610 1765 Øe 380 1"1/4 1"1/2
1000 1042 181 1000 2221 2436 105 458 503 593 683 743 993 // 1664 1818 Øe 380 1"1/2 2"
1500 1445 224 1100 2415 2654 109 440 585 675 765 825 1075 // 1895 2050 Øe 380 1”1/2 2”
2000 1978 279 1300 2492 2811 91 467 587 692 797 867 842 1952 1877 2057 Øe 430 2” 2”
AND SPARE PARTS
ACCESORIES
2000 1978 279 1360 2492 2560 91 467 587 692 797 867 842 1952 1877 2057 Øe 430 2" 2"
2500 2315 328 1350 2311 2470 140 551 671 776 881 951 976 1816 1732 1891 Øe 430 2" 2"
3000 2921 384 1350 2811 2940 140 551 731 836 941 1011 1036 2316 2232 2391 Øe 430 2" 2"
4000 3769 521 1500 2875 3040 114 570 750 855 960 1030 1035 2315 2238 2410 Øe 430 2" 2"
5000 4982 657 1700 2915 3120 94 580 750 855 960 1030 1035 2335 2265 2420 Øe 430 2" 2"
15
EXTRA1 - HEAT EXCHANGERS TECHNICAL DATA
Cordivari heat exchangers, with tubes bent to the bottom, are able to heat the complete quantity of volume in an homogeneus way.
Energy storaging is therefore improved and Ignition time data have to be referred to the complete volume of the tank, while in traditional straight heat exchangers
equipped calorifires, a range between 9-17% of volume remains cold.
0,5 m 2
180
1800
5000
1,5 m2 500,0
160
1600
1400 140
4000 400,0
[mm H2O]
120 2 m2
[mbar]
[mm H2O]
1200
[mbar]
400 40
1000 100,0
200 20
0 0,0
0 0
0 2 4 6 8 10 12 14 16 18
0 1 2 3 4 5 6
Flow Rate [m /h] 3 Flow Rate [m3/h]
16
EXTRA- BOLLY®
EXTRA1 - HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
BOLLYTERM®
CALORIFIERS
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
STAINLESS STEEL
storage at t2 and primary at T1 storage at t2 and primary at T1
CALORIFIERS
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
247 319 328 347 360 498 542 635 2 309 30,3
241 308 314 329 330 446 478 547 1 84,74 8,3
371 480 494 524 545 755 823 968 3 372 36,5
362 464 474 496 501 678 729 834 1,5 101,02 9,9
616 791 810 851 849 1162 1254 1450 4 419 41,1
CALORIFIERS FOR
604 770 784 814 792 1061 1129 1273 2 113,381 11,1
HEAT PUMP
998 1280 1310 1373 1359 1855 1998 2301 6 718 70,4
980 1249 1271 1318 1275 1705 1812 2037 3 189,22 18,6
1273 1640 1683 1776 1788 2469 2678 3123 10 1380 135,3
1252 1601 1635 1707 1687 2283 2446 2790 5 358,5 35,2
1855 2394 2462 2605 2651 3675 4000 4689 15 2295 225,1
1825 2338 2392 2504 2506 3407 3664 4204 7,5 589,6 57,8
2546 3285 3377 3571 3622 5019 5459 6391 20 2996 293,8
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2507 3212 3285 3439 3435 4670 5021 5761 10 766,42 75,2
2988 3856 3965 4196 4296 5951 6475 7586 20 2436 238,9
2936 3760 3845 4023 4047 5491 5899 6755 10 624 61,2
3748 4827 4955 5226 5307 7314 7928 9230 20 2836 278,1
3685 4710 4809 5015 5004 6752 7226 8215 10 723 70,9
4842 6232 6396 6740 6892 9475 10263 11913 20 3896 382,1
4756 6070 6196 6452 6477 8699 9301 10533 10 989 97,0
6362 8166 8363 8775 8891 12137 13081 15058 20 4707 461,6
6252 7963 8109 8409 8363 11161 11860 13303 10 1192 116,9
HYDRONIC
Chart for surfaces of: 4 m2 / 5 m2 / 6 m2 Chart for surfaces of: 8 m2 / 10 m2
Flow Rate [lt/min]
Flow Rate [lt/min] 0 50 100 150 200 250 300 350 400 Heat exchanger surface [m2]
5000
0 50 100 150 200 250 300 350 400
5000
10 m2 200 0,5
INERTIAL
450
4500
TANKS
4500
450
400
300 0,75
4000 8 m2
4000 400
350
500 1
3500
3500 350
800 1,5
[mm H2O]
[mm H2O]
3000 300
4 m2
[mbar]
[mbar]
3000 300
1000 2
6m 2
2500 250
1500 3
WATER PRESSURE
2500 250
5 m2 2000 200
2000 200
2000 4
TANKS
1500 150
1500 150
2500 5
1000 100
1000 100
3000 6
500 50
500 50
4000 8
0 0
0
0 5 10 15 20 25
0
0 5 10 15 20 25 5000 10
COMPRESSED AIR
Advantage in Advantage in
Standard heat Heat exchanger for
Model storaged volume percentage
exchanger 100% heated volume
[litres] [litres] [litres] [%]
1500 1224 1445 221 15%
2000 1684 1978 294 15%
2500 1905 2315 410 18%
3000 2438 2921 483 17%
TECHNICAL
SUPPORT
17
EXTRA1 COMPACT
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
POLYWARM®
ENERGY
EXTRA 1 COMPACT WXC
SOFT FLEECE INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. € FOR MODELS Art. Nr. €
5032240000107 84,00 Art. Nr. € Model
5005000310002 455,00 WXC
5 units box 5200000000011 319,00 1500
5200000000013 571,00 2000÷4000
18
EXTRA1 COMPACT
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive. LOW-CEILINGED ROOMS
MAX HEIGHT
250 cm
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
(14)
CALORIFIERS FOR
HEAT PUMP
1 Drain 1” Gas F
H
(16) 3
connection for more boilers
H6 (7) H7 (8) H5 (6)
CYLINDERS - PUFFER
4 Primary circuit outlet
MULTIFUEL ENERGY
H4 (5) H3 (4) 5 Heat exchanger flange
H2 (2) (3) 6 Primary circuit inlet
7 Connection for instrumentation 1/2" Gas F
H1(1)
0 8 Connection for magnesium anode 1"1/4 Gas F
Connection for 2nd anode 1"1/4 Gas F (only for models
9
> 1500)
HYDRONIC
10 Connection for electrical immersion
(14) 11
Connection for recirculation or for domestic hot water
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
(4) (5) (6) (16)
WATER PRESSURE
The calorifier has two gripps on the bottom
TANKS
which allows the use of forklift when handling
and already equipped with mounted drainage
tube.
H1 (15) COMPRESSED AIR
RECEIVERS
Volume Weight De H A H1 H2 H3 H4 H5
Model
[lt] [kg] [mm]
1500 1509 221 1360 1992 2094 91 467 602 692 782
2000 2012 300 1510 2111 2241 140 551 671 776 881
2500 2627 393 1500 2125 2353 114 570 690 795 900
AND SPARE PARTS
3000 3029 472 1600 2140 2400 109 575 695 800 905
ACCESORIES
4000 3990 565 1700 2415 2668 94 580 730 835 940
2-3
H6 H7 H15 H16 H17 5 4-6 7-12 8 9
Model 11-13
[mm] Connections Gas F
1500 867 942 // 1377 1557 Øe 380 2" 2" 1/2" 1"1/4 //
TECHNICAL
SUPPORT
2000 951 976 1566 1482 1641 Øe 430 2" 2" 1/2" 1"1/4 1"1/4
2500 970 975 1585 1488 1660 Øe 430 2" 2" 1/2" 1"1/4 1"1/4
3000 975 980 1600 1520 1675 Øe 430 2" 2" 1/2" 1"1/4 1"1/4
4000 1010 1015 1855 1765 1920 Øe 430 2" 2" 1/2" 1"1/4 1"1/4
19
EXTRA1 COMPACT- HEAT EXCHANGERS TECHNICAL DATA
Cordivari heat exchangers, with tubes bent to the bottom, are able to heat the complete quantity of volume in an homogeneus way.
Energy storaging is therefore improved and Ignition time data have to be referred to the complete volume of the tank, while in traditional straight heat exchangers
equipped calorifires, a range between 9-17% of volume remains cold.
2000 4
2500 5 5000
500,0
3000 6
4000 8 4000 400,0
[mm H2O]
[mbar]
3000 300,0
3 m2
2000 200,0
1000 100,0
0 0,0
0 2 4 6 8 10 12 14 16 18
Flow Rate [m /h] 3
450 450
4500 4500
3000
4m 2
300 3000 300
[mm H2O]
[mm H2O]
[mbar]
5 m2
200 2000 200
2000
50 500 50
500
0 0
0 0
0 5 10 15 20 25
0 5 10 15 20 25
Flow Rate [m3/h] Flow Rate [m /h] 3
20
EXTRA- BOLLY®
EXTRA1 COMPACT- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
BOLLYTERM®
CALORIFIERS
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
STAINLESS STEEL
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
CALORIFIERS
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
1927 2484 2552 2695 2723 3765 4090 4779 15 2295 225,1
1897 2428 2482 2594 2578 3497 3754 4294 7,5 589,6 57,8
2573 3319 3411 3605 3649 5053 5493 6425 20 2996 293,8
CALORIFIERS FOR
HEAT PUMP
2534 3247 3320 3474 3462 4704 5056 5795 10 766,42 75,2
3276 4198 4289 4484 4352 5932 6372 7304 20 2436 238,9
3237 4125 4198 4352 4165 5583 5934 6673 10 624 61,2
3862 4969 5097 5368 5420 7455 8069 9371 20 2836 278,1
3798 4852 4950 5156 5117 6893 7368 8357 10 723 70,9
5090 6542 6706 7050 7140 9785 10573 12223 20 3896 382,1
CYLINDERS - PUFFER
5004 6380 6506 6762 6725 9009 9611 10843 10 989 97,0
MULTIFUEL ENERGY
PRESSURE LOSS - CURVED HEAT EXCHANGERS
Chart for surfaces of: 6 m2 Chart for surfaces of: 8 m2
Flow Rate [lt/min] Flow Rate [lt/min]
0 50 100 150 200 250 300 350 400 0 50 100 150 200 250 300 350 400
5000 5000
HYDRONIC
450 450
4500 4500
400
4000 400 4000 8m 2
300 300
[mm H2O]
3000 3000
[mbar]
[mm H2O]
6 m2
[mbar]
INERTIAL
TANKS
2000 200 2000 200
WATER PRESSURE
500 50 500 50
0 0 0 0
TANKS
0 5 10 15 20 25 0 5 10 15 20 25
Flow Rate [m /h] 3
Flow Rate [m /h]
3
COMPRESSED AIR
RECEIVERS
Advantage in Advantage in
Standard heat Heat exchanger for
Model storaged volume percentage
exchanger 100% heated volume
[litres] [litres] [litres] [%]
1500 1282 1509 227 15%
2000 1711 2012 301 15%
2500 2162 2627 465 18%
3000 2528 3029 501 18%
TECHNICAL
SUPPORT
21
EXTRA 1 - HEAT EXCHANGERS TECHNICAL DATA
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
95
85
75
65 2 m2
Output [kW]
55
45 1,5 m 2
35
25
15
5
55 60 65 70 75 80
Primary circuit temperature [°C]
95
85
75
65
Output [kW]
55
45
35
1 m2
25
0,75 m 2
15
0,5 m 2
5
55 60 65 70 75 80
Primary circuit temperature [°C]
22
EXTRA- BOLLY®
EXTRA 1 - HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
450
400
STAINLESS STEEL
CALORIFIERS
350
10 m 2
300
Output [kW]
CALORIFIERS FOR
250
HEAT PUMP
6 m2
200
150 4 m2
CYLINDERS - PUFFER
MULTIFUEL ENERGY
100
50
55 60 65 70 75 80
Primary circuit temperature [°C]
HYDRONIC
Extractable heat exchanger surface 4 m2 6 m2 10 m2
MAX MIN MAX MIN MAX MIN
Flow rate [m3/h]
20 10 20 10 20 10
350
INERTIAL
TANKS
300
8 m2
WATER PRESSURE
250
TANKS
200
Output [kW]
5 m2
COMPRESSED AIR
RECEIVERS
150
3 m2
100
AND SPARE PARTS
ACCESORIES
50
0
55 60 65 70 75 80
TECHNICAL
SUPPORT
23
EXTRA 2
POLYWARM® COATED CALORIFIERS WITH 2 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGERS
POLYWARM®
Model insulation
Art. Nr. [m ]
2
www.cordivari.com/erp
ENERGY
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool EXTRA 2 WXC
STAINLESS STEEL
EFFICIENCY
HEAT EXCHANGER SURFACE CLASS
DISMOUNTABLE SOFT FLEECE
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Titanium electronic anode
ART. NR. FOR MODELS
5005000310002 WXC See Accessories section
5005000310003 WXB
24
EXTRA 2
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 2 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGERS
BOLLYTERM®
1500 ÷ 5000 6 bar to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
(18)
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
H17 (15) CERTIFIED LABORATORIES
(16) (17) DATA RESULTS
H16 (14) Drain 1” 1/4 F.
H15 (13) 1
For model 1000 connection 1” 1/2 F
2 Domestic cold water circuit inlet
H11 (12) (20) Alternative domestic cold water circuit inlet or
CALORIFIERS FOR
H10 (11) 3
connection for more boilers
HEAT PUMP
H9 (10)
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H2 (2) (3) 7-12 Connection for instrumentation 1/2” F
8 Connection for magnesium anode 1" 1/4 F
Upper heat exchanger outlet 1” F
H1 (1) 9
For models > 800 connection 2” F
0
10 Heat exchanger flange Upper
Upper heat exchanger inlet 1” F
11
For models > 800 connection 2” F
HYDRONIC
(18) Connection for 2nd anode 1”1/4 Gas F (only for
(1) (2) (15) (3) (17) 13
models > 1500)
H1 (15) Connection for electrical immersion 1” 1/2 F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
14
For models > 800 connection 2" Gas F
(7) (12) (14) (16) (8) (13) Models from 1500 to 5000 have two 15-17 Connection for recirculation or for domestic hot water
gripps on the bottom which allow
(4) (5) (6) (9) (10) the use of forklift when handling and 16 Connection for instrumentation 1/2” Gas F
INERTIAL
TANKS
(11) (19) (20) (21) drain pipe already fitted. 18 Domestic hot water outlet
19-20 Heat exchangers air purge 3/8” Gas F
21 Drain 1” Gas F (only for models > 1000)
WATER PRESSURE
HARD FOAM INSULATION (WXB)
TANKS
2-3
Volume Weight De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H15 H16 H17 5-10 18
Model 15-17
[lt] [kg]
200 193 70 550 1449 1550 85 325 360 410 460 520 650 810 860 910 970 // 1075 1185 Øe 300 1"1/4 1"1/4
300 295 84 650 1499 1635 85 350 385 435 485 545 735 835 885 935 995 // 1100 1210 Øe 300 1"1/4 1"1/4
500 503 112 750 1800 1950 85 375 410 460 510 570 760 860 910 960 1020 // 1329 1485 Øe 300 1"1/4 1"1/4
COMPRESSED AIR
800 799 177 900 2135 2320 85 405 450 540 630 690 870 1000 1090 1180 1240 // 1610 1765 Øe 380 1"1/4 1"1/4
RECEIVERS
1000 1047 226 1000 2221 2436 105 458 503 593 683 743 993 1053 1143 1233 1293 // 1664 1818 Øe 380 1"1/2 1"1/2
1500 1450 269 1100 2415 2654 109 440 585 675 765 825 1075 1160 1250 1340 1400 // 1895 2050 Øe 380 1"1/2 2"
2000 1985 337 1300 2492 2811 91 467 587 692 797 867 842 1157 1262 1367 1437 1952 1877 2057 Øe 430 2" 2"
AND SPARE PARTS
ACCESORIES
2000 1985 337 1360 2492 2560 91 467 587 692 797 867 842 1157 1262 1367 1437 1952 1877 2057 Øe 430 2" 2"
2500 2322 399 1350 2311 2470 140 551 671 776 881 951 976 1271 1376 1481 1551 1816 1732 1891 Øe 430 2" 2"
3000 2928 464 1350 2811 2940 140 551 731 836 941 1011 1036 1371 1476 1581 1651 2316 2232 2391 Øe 430 2" 2"
4000 3776 618 1500 2875 3040 114 570 750 855 960 1030 1035 1390 1495 1600 1670 2315 2238 2410 Øe 430 2" 2"
5000 4990 768 1700 2915 3120 94 580 750 855 960 1030 1035 1400 1505 1610 1680 2335 2265 2420 Øe 430 2" 2"
25
EXTRA2 - HEAT EXCHANGERS TECHNICAL DATA
Cordivari heat exchangers, with tubes bent to the bottom, are able to heat the complete quantity of volume in an homogeneus way.
Energy storaging is therefore improved and Ignition time data have to be referred to the complete volume of the tank, while in traditional straight heat exchangers
equipped calorifires, a range between 9-17% of volume remains cold.
26
EXTRA- BOLLY®
EXTRA2 - HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
BOLLYTERM®
CALORIFIERS
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
STAINLESS STEEL
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
140 184 194 213 253 364 408 502 2 294,35 28,9
133 174 180 194 223 312 344 412 1 80,5 7,9
CALORIFIERS FOR
215 284 298 328 389 560 628 773 3 355,7 34,9
HEAT PUMP
206 268 279 301 345 483 534 639 1,5 95,97 9,4
418 555 585 648 781 1132 1275 1577 6 682 66,9
400 524 546 593 697 982 1088 1314 3 179 17,6
689 910 954 1046 1207 1741 1950 2395 10 1311 128,6
668 871 905 977 1105 1555 1719 2063 5 341 33,4
816 1066 1107 1195 1312 1859 2058 2480 10 1311 128,6
CYLINDERS - PUFFER
MULTIFUEL ENERGY
794 1025 1057 1124 1203 1664 1816 2136 5 341 33,4
1149 1512 1579 1723 1947 2795 3118 3810 15 2181 213,9
1119 1456 1509 1622 1801 2526 2783 3324 7,5 560 54,9
1595 2095 2187 2382 2672 3831 4273 5209 20 2846 279,1
1556 2023 2096 2250 2485 3483 3834 4573 10 728 71,4
1652 2186 2296 2527 2963 4285 4809 5921 20 2314 226,9
1600 2091 2176 2354 2714 3825 4233 5089 10 592 58,1
2303 3021 3149 3420 3865 5511 6124 7426 20 2745 269,2
2240 2904 3003 3209 3561 4949 5423 6411 10 700 68,6
HYDRONIC
2972 3894 4059 4403 5026 7141 7930 9583 20 3701 362,9
2886 3735 3858 4115 4610 6374 6967 8198 10 939 92,1
3882 5066 5263 5674 6414 9040 9987 11959 20 4472 438,6
3772 4863 5008 5309 5886 8064 8764 10208 10 1132 111,0
INERTIAL
TANKS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
WATER PRESSURE
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
TANKS
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
247 319 328 347 360 498 542 635 2 309 30,3
241 308 314 329 330 446 478 547 1 84,74 8,3
371 480 494 524 545 755 823 968 3 372 36,5
362 464 474 496 501 678 729 834 1,5 101,02 9,9
COMPRESSED AIR
649 844 874 937 1011 1420 1563 1866 6 718 70,4
RECEIVERS
632 813 836 882 927 1270 1378 1602 3 189,22 18,6
1039 1347 1391 1483 1555 2177 2386 2831 10 1380 135,3
1018 1308 1342 1414 1453 1990 2154 2498 5 358,5 35,2
1347 1759 1826 1970 2143 3041 3365 4056 15 2295 225,1
1316 1703 1756 1869 1998 2773 3029 3569 7,5 589,6 57,8
1855 2394 2462 2605 2651 3675 4000 4689 15 2295 225,1
AND SPARE PARTS
1825 2338 2392 2504 2506 3407 3664 4204 7,5 589,6 57,8
ACCESORIES
2546 3285 3377 3571 3622 5019 5459 6391 20 2996 293,8
2507 3212 3285 3439 3435 4670 5021 5761 10 766,42 75,2
2927 3761 3852 4046 4003 5495 5935 6867 20 2436 238,9
2888 3688 3761 3915 3815 5146 5497 6236 10 624 61,2
3748 4827 4955 5226 5307 7314 7928 9230 20 2836 278,1
3685 4710 4809 5015 5004 6752 7226 8215 10 723 70,9
4842 6232 6396 6740 6892 9475 10263 11913 20 3896 382,1
4756 6070 6196 6452 6477 8699 9301 10533 10 989 97,0
TECHNICAL
SUPPORT
6362 8166 8363 8775 8891 12137 13081 15058 20 4707 461,6
6252 7963 8109 8409 8363 11161 11860 13303 10 1192 116,9
27
EXTRA2 - PRESSURE LOSS - LOWER CURVED HEAT EXCHANGERS
Lower heat exchanger surface [m2]
200 0,5 Chart for surfaces of: 0,5 m2 / 0,75 m2 / 1 m2
POLYWARM®
300 0,75
Flow Rate [lt/min]
500 1,5 0 10 20 30 40 50 60 70 80 90 100
2000
800 2
0,5 m2 180
1000 3 1800
1500 3 1600
160
2500 5
[mm H2O]
1200 120
3000 6
[mbar]
0,75 m2
4000 8 1000 100
5000 10 800 80
1 m2
600 60
400 40
200 20
0 0
0 1 2 3 4 5 6
450
4500
5000
1,5 m2 500,0
4000 400
3500 350
4000 400,0
2 m2 3000 4m 2
300
[mm H2O]
[mm H2O]
[mbar]
[mbar]
[mbar]
250
3000 300,0 2500 5 m2
3 m2
2000 200
1000 100
1000 100,0
500 50 4m
0 0
0 0,0 0 5 10 15 20 25
0 2 4 6 8 10 12 14 16 18
[mm H2O]
[mbar]
6 m2
2500 250 2500 250
500 50 500 50
0 0 0 0
0 5 10 15 20 25 0 5 10 15 20 25
28
EXTRA- BOLLY®
EXTRA2 - PRESSURE LOSS
CALORIFIERS
- UPPER STRAIGHT HEAT EXCHANGERS
Upper heat exchanger surface [m2]
200 0,5 Chart for surfaces of: 0,5 m2 / 0,75 m2 / 1 m2
POLYWARM®
BOLLYTERM®
500 1,5
CALORIFIERS
0 10 20 30 40 50 60 70 80 90 100
2000
800 2
180
1800
1000 2 0,5 m2
1500 3 1600
160
2000 4 1400
140
2500 5
STAINLESS STEEL
120
[mm H2O]
CALORIFIERS
1200
[mbar]
3000 6
100
4000 8 1000
0,75 m2
5000 10 800 80
600
1m 2
60
CALORIFIERS FOR
400 40
HEAT PUMP
200 20
0 0
0 1 2 3 4 5 6
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Chart for surfaces of: 1,5 m2 / 2 m2 / 3 m2 Chart for surfaces of: 4 m2 / 5 m2
Flow Rate [lt/min] Flow Rate [lt/min]
q
0 50 100 150 200 250 300
5000
1,5 m2 0 50 100 150 200 250 300 350 400
450,0 5000
4500
450,0
4500
400,0
4000
HYDRONIC
4000 400,0
3500 350,0
2m 2
3500 350,0
300,0
[mm H2O]
[mm H2O]
3000
4 m2 300,0
[mbar]
[mbar]
3000
2500 3 m2 250,0
2500 250,0
5 m2
2000 200,0 2000 200,0
1500 150,0
1500 150,0
INERTIAL
TANKS
1000 100,0
1000 100,0
500 50,0
500 50,0
0 0,0
0 0,0 0 5 10 15 20 25
0 2 4 6 8 10 12 14 16 18
WATER PRESSURE
TANKS
Chart for surfaces of: 6 m2 / 8 m2 Chart for surfaces of: 10 m2
COMPRESSED AIR
4000 400,0
4000 400,0
8 m2
AND SPARE PARTS
3500 350,0
3500 350,0
ACCESORIES
[mm H2O]
[mm H2O]
3000 300,0
300,0
[mbar]
[mbar]
3000
6 m2 250,0
250,0 2500
2500
2000 200,0
2000 200,0
1500 150,0
1500 150,0
1000 100,0
1000 100,0
500 50,0
50,0
TECHNICAL
500
SUPPORT
0 0,0
0 0,0
0 5 10 15 20 25
0 5 10 15 20 25
29
EXTRA 3
POLYWARM® COATED CALORIFIERS WITH 3 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGERS
POLYWARM®
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5005000310002 WXC 5032240000107 Art. Nr. Model
5005000310003 WXB 5 units box 5200000000011 1500
5200000000013 2000÷5000
30
EXTRA 3
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 3 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De 1 Drain 1” F
(21) Domestic cold water circuit inlet 1/2” F
2
For models > 1500 connection 2” F
CALORIFIERS FOR
Alternative domestic cold water circuit inlet or connection
HEAT PUMP
3 for more boilers 1/2” F
H17 (15)
(16) (17) (18) For models > 1500 connection 2” F
(25) 4 Lower heat exchanger outlet 2” F
H15 (13) H14 (20)
H13 (14) 5 Heat exchanger flange Lower
H12 (19)
6 Lower heat exchanger inlet 2” F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H11 (12) (24) 7-12 Connection for instrumentation 1/2” F
H10 (11) 8 Connection for magnesium anode 1"1/4 F
H9 (10) 9 Middle heat exchanger outlet 2” F
A
H8 (9)
10 Middle heat exchanger flange
H
H7 (8)
11 Middle heat exchanger inlet 2” F
(23)
H6 (7) H5 (6) 13 Connection for 2nd anode 1”1/4 F (only for models > 1500)
H4 (5)
H3 (4) 14 Heat exchanger flange Upper
H2 (2) (3)
HYDRONIC
Connection for recirculation or for domestic hot water
15-18 1/2” F
For models > 1500 connection 2” F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)
0 16-17 Connection for instrumentation 1/2” F
19 Upper heat exchanger outlet 2” F
20 Upper heat exchanger inlet 2” F
INERTIAL
21 Domestic hot water outlet 2” F
TANKS
23-24
Heat exchangers air purge 3/8” Gas F
25
H1 (15)
WATER PRESSURE
The calorifier have two gripps on the
bottom which allow the use of forklift
TANKS
when handling and already equipped
with mounted drainage tube.
(7) (12) (16) (8) (13) (17)
2000 1991 430 1300 2492 2811 91 467 587 692 797 867 842 1157 1262 1367 1437 1727 1817 1907 1592 2057
ACCESORIES
31
EXTRA3 - HEAT EXCHANGERS TECHNICAL DATA
Cordivari heat exchangers, with tubes bent to the bottom, are able to heat the complete quantity of volume in an homogeneus way.
Energy storaging is therefore improved and Ignition time data have to be referred to the complete volume of the tank, while in traditional straight heat exchangers
equipped calorifires, a range between 9-17% of volume remains cold.
32
EXTRA- BOLLY®
EXTRA3 - HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
BOLLYTERM®
CALORIFIERS
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
STAINLESS STEEL
storage at t2 and primary at T1 storage at t2 and primary at T1
CALORIFIERS
T1/t2 T1/t2
[m3 /h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
520 683 713 776 882 1259 1402 1704 6 682 66,9
503 652 674 721 797 1109 1215 1441 3 179 17,6
811 1062 1106 1199 1327 1891 2102 2547 10 1311 128,6
790 1024 1058 1130 1226 1706 1869 2214 5 341 33,4
1081 1427 1495 1639 1877 2708 3033 3724 15 2181 213,9
CALORIFIERS FOR
1051 1371 1425 1538 1732 2440 2697 3238 7,5 560 54,9
HEAT PUMP
2152 2282 2921 3152 3461 2367 5432 6542 20 2314 226,9
2101 2716 2801 2979 3212 4447 4855 5711 10 592 58,1
CYLINDERS - PUFFER
MULTIFUEL ENERGY
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
HYDRONIC
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
1149 1512 1579 1723 1947 2795 3118 3810 15 2181,03 213,9
1119 1456 1509 1622 1801 2526 2783 3324 7,5 560,28 54,9
1595 2095 2187 2382 2672 3831 4273 5209 20 2846,25 279,1
1556 2023 2096 2250 2485 3483 3834 4573 10 728,1 71,4
2303 3021 3149 3420 3865 5511 6124 7426 20 2745,34 269,2
INERTIAL
TANKS
2240 2904 3003 3209 3561 4949 5423 6411 10 700,69 68,7
3882 5066 5263 5674 6414 9040 9987 11959 20 4472,31 438,6
3772 4863 5008 5309 5886 8064 8764 10208 10 290,29 28,5
WATER PRESSURE
TANKS
COMPRESSED AIR
RECEIVERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
1855 2394 2462 2605 2651 3675 4000 4689 15 2295 225,1
1825 2338 2392 2504 2506 3407 3664 4204 7,5 589,6 57,8
AND SPARE PARTS
2546 3285 3377 3571 3622 5019 5459 6391 20 2996 293,8
ACCESORIES
2507 3212 3285 3439 3435 4670 5021 5761 10 766,42 75,2
3748 4827 4955 5226 5307 7314 7928 9230 20 2836 278,1
3685 4710 4809 5015 5004 6752 7226 8215 10 723 70,9
6362 8166 8363 8775 8891 12137 13081 15058 20 4707 461,6
6252 7963 8109 8409 8363 11161 11860 13303 10 1192 116,9
TECHNICAL
SUPPORT
33
EXTRA3 - PRESSURE LOSS - LOWER CURVED HEAT EXCHANGERS
5000 10 1600
160
1400 140
[mm H2O]
1200 120
[mbar]
0,75 m2 100
1000
800 80
1 m2
600 60
400 40
200 20
0 0
0 1 2 3 4 5 6
450
4500
5000
1,5 m2 500,0
4000 400
3500 350
4000 400,0
2 m2 3000 4m 2
300
[mm H2O]
[mm H2O]
[mbar]
[mbar]
250
3000 300,0 2500 5 m2
3 m2
2000 200
1000 100
1000 100,0
500 50 4m
0 0
0 0,0 0 5 10 15 20 25
0 2 4 6 8 10 12 14 16 18
[mm H2O]
[mbar]
6 m2
2500 250 2500 250
500 50 500 50
0 0 0 0
0 5 10 15 20 25 0 5 10 15 20 25
34
EXTRA- BOLLY®
EXTRA3 - PRESSURE LOSS
CALORIFIERS
- UPPER/MIDDLE STRAIGHT HEAT EXCHANGERS
BOLLYTERM®
Middle Upper
CALORIFIERS
0 10 20 30 40 50 60 70 80 90 100
2000
1500 3 1,5
180
2000 4 2
1800
0,5 m2
3000 6 3 1600
160
5000 10 5 1400
140
STAINLESS STEEL
120
[mm H2O]
CALORIFIERS
1200
[mbar]
1000 100
0,75 m2
800 80
600
1m 2
60
CALORIFIERS FOR
400 40
HEAT PUMP
200 20
0 0
0 1 2 3 4 5 6
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Chart for surfaces of: 1,5 m2 / 2 m2 / 3 m2 Chart for surfaces of: 4 m2 / 5 m2
Flow Rate [lt/min] Flow Rate [lt/min]
q
0 50 100 150 200 250 300
5000
1,5 m2 0 50 100 150 200 250 300 350 400
450,0 5000
4500
450,0
4500
400,0
4000
HYDRONIC
4000 400,0
3500 350,0
2m 2
3500 350,0
300,0
[mm H2O]
[mm H2O]
3000
4 m2 300,0
[mbar]
[mbar]
3000
2500 3 m2 250,0
2500 250,0
5 m2
2000 200,0 2000 200,0
1500 150,0
1500 150,0
INERTIAL
TANKS
1000 100,0
1000 100,0
500 50,0
500 50,0
0 0,0
0 0,0 0 5 10 15 20 25
0 2 4 6 8 10 12 14 16 18
WATER PRESSURE
TANKS
Chart for surfaces of: 6 m2 / 8 m2 Chart for surfaces of: 10 m2
COMPRESSED AIR
4000 400,0
4000 400,0
8 m2
AND SPARE PARTS
3500 350,0
3500 350,0
ACCESORIES
[mm H2O]
[mm H2O]
3000 300,0
300,0
[mbar]
[mbar]
3000
6 m2 250,0
250,0 2500
2500
2000 200,0
2000 200,0
1500 150,0
1500 150,0
1000 100,0
1000 100,0
500 50,0
50,0
TECHNICAL
500
SUPPORT
0 0,0
0 0,0
0 5 10 15 20 25
0 5 10 15 20 25
35
EXTRA1 HORIZONTAL
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
POLYWARM®
ENERGY
EXTRA 1 WXC OR STAINLESS STEEL EFFICIENCY
CLASS
HEAT EXCHANGER
DISMOUNTABLE SOFT FLEECE SURFACE
ErP
SOFT FLEECE INSULATION
Model insulation
Art. Nr. [m2]
200 3072161430031 0,5 C
300 3072161430032 0,75 C
500 3072161430033 1 C
800 3072161430034 1,5 C
1000 3072161430035 2 C
1500 3072161430036 3 C
2000 3072161430037 4 C
3000 3072161430008 5
4000 3072161430009 8
5000 3072161430011 10
www.cordivari.com/erp
On line ErP label tool
Data have been calculated on following basis: Primary circuit at 80 °C, and proper energy source; Production of DHW in continue way from 10 °C at t2; DHW that can be
taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C; Sanitary water according to UNI CTI 8065.
Even if tanks are tested to resist till max temperature, the local legislation has always to be observed during the use.
Continous
DHW produced in the DHW produced
Ignition Time Output production of Flow rate Exchanger pressure loss
Model first 10 Min. in the first hour
DHW
[min] [Kw] [lt/h] [lt/10’] [lt/60’] [m3/h] [mm.H2O] [mbar]
200 49 18 455 347 635 2 309 30,3
300 48 28 701 524 968 3 372 36,5
500 60 38 947 844 1443 4 419 41,1
800 59 59 1466 1301 2230 6 718 70,4
1000 54 86 2127 1776 3123 10 1380 135,3
1500 53 133 3290 2677 4761 15 2295 225,1
2000 52 180 4453 3564 6384 20 2996 293,8
3000 65 216 5361 5144 8539 20 2436 238,9
4000 57 330 8168 6918 12092 20 3896 382,1
5000 60 401 9921 8639 14923 20 4707 461,6
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5032240000107 Art. Nr. Model
5005000310002 WXC
5 units box 5200000000008 200, 300
5200000000009 500, 800
5200000000011 1000, 1500
5200000000013 2000÷5000
36
EXTRA1 HORIZONTAL
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
L1 L5 L2 CERTIFIED LABORATORIES
0 (9) (7) (11) (10) (6) DATA RESULTS
(4) (5)
1 Primary circuit outlet
CALORIFIERS FOR
2 Primary circuit inlet
HEAT PUMP
(8) (3)
De
CYLINDERS - PUFFER
MULTIFUEL ENERGY
L3 L L4 9 - 10 Domestic hot water inlet / Drain
Connection for 2nd anode 1”1/4 Gas F (only for models >
11
1500)
200
12 Heat exchanger air purge 3/8" Gas F
(11)
H6(4)
(5) 45°
HYDRONIC
H5 (3)
H
H4 (2)
H3
H2 (1)
H1 (9) (10)
0 VERSION WITH 2 EXTRACTABLE HEAT
I EXCHANGERS ARE AVAILABLE UPON
INERTIAL
TANKS
REQUEST
Volume De L H L1 L2 L3 L4 L5 H1
Model
[lt] [mm]
WATER PRESSURE
200 191 670 1594 693 344 1144 409 1079 // 43
300 292 770 1645 849 370 1170 440 1100 // 99
TANKS
500 500 870 1934 946 395 1445 490 1350 // 96
800 795 970 2251 1042 425 1725 555 1595 // 92
1000 1045 1070 2281 1137 458 1758 588 1628 // 87
1500 1498 1210 2651 1240 474 2024 629 1869 // 90
2000 2064 1360 2706 1380 520 2070 660 1930 908 80
COMPRESSED AIR
3000 2997 1350 2956 1524 495 2295 695 2095 945 154
RECEIVERS
4000 4184 1550 3066 1707 560 2360 665 2255 1010 137
5000 5131 1700 3107 1845 583 2383 783 2183 1033 125
200 243 293 343 368 498 364 1" 1/2'' 1''1/4 1''1/4 -
300 336 386 436 474 668 404 1" 1/2'' 1''1/4 1''1/4 -
500 383 433 483 521 715 455 1" 1/2'' 1''1/4 1''1/4 -
800 348 438 528 567 817 583 2'' 1/2'' 1''1/4 1''1/2 -
1000 277 367 457 612 917 644 2'' 1/2'' 1''1/2 1''1/2 -
1500 315 405 495 665 1020 759 2'' 1/2'' 2'' 2'' -
TECHNICAL
SUPPORT
2000 330 435 540 730 1085 848 2'' 1/2'' 2'' 2'' 1''1/4
3000 324 429 534 829 1184 981 2'' 1/2'' 2'' 2'' 1''1/4
4000 307 412 517 912 1267 1101 2'' 1/2'' 2'' 3'' 1''1/4
5000 305 410 515 975 1330 1189 2'' 1/2'' 2'' 3'' 1''1/4
37
EXTRA1 VAPORE
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
FOR STEAM GENERATOR
APPLICATION CATHODE PROTECTION
Production and storage of sanitary hot water. Suitable for steam Magnesium anode. Models > 1500 n° 2 magnesium anode.
generators. DRAIN
MATERIAL External confluence through drain connection.
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Models > 1000 external confluence through drain pipe.
- UBA - WRAS) GASKET- FLANGE PLATE
HEAT EXCHANGER Asbestos-free fiber gaskets
1 stainless steel 316L straight heat exchanger suitable for steam Mild steel exchanger head with anticorrosion treatment.
power. WARRANTY
INSULATION 5 years - See general sales conditions and warranty
- HARD: High thermal insulation with ecological polyurethane hard foam. ACCESSORIES AND SPARE PARTS
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, See Accessories section for the entire list
with high thermal insulation. Fire resistance class B-s2d0 according
to EN 13501.
Grey PVC external lining complete with top and flange cover
POLYWARM®
HARD FOAM INSULATION
ENERGY
EXTRA 1 VAPORE WXB STAINLESS STEEL EFFICIENCY
CLASS
HEAT EXCHANGER
HARD FOAM SURFACE
Model insulation ErP
Art. Nr. [m2]
500 3069162360123 1 C
800 3069162360124 1,5 C
1000 3069162360125 2 C
1500 3069162360126 3 C
2000 3069162360127 3 C
www.cordivari.com/erp ENERGY
EXTRA 1 VAPORE WXC STAINLESS STEEL EFFICIENCY
On line ErP label tool CLASS
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
HEAT EXCHANGER
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5005000310002 WXC 5032240000107 Art. Nr. Model
5005000310003 WXB 5 units box 5200000000009 500, 800
5200000000011 1000, 1500
5200000000013 2000÷5000
38
EXTRA1 VAPORE
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGER
FOR STEAM GENERATOR
STORAGE HEAT EXCHANGER T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
Model Pmax Tmax Pmax Tmax that test procedures and
500 ÷ 1000 8 bar Cordivari LAB are certified conforming
90 °C 6 bar 165 °C
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
1500 ÷ 5000 6 bar indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
(14)
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
H17 (11)
(12) (13) Drain 1” 1/4 F
H16 (10) 1
For model 800 connection 1” 1/2 F
H15 (9)
CALORIFIERS FOR
2 Domestic cold water circuit inlet
HEAT PUMP
Alternative domestic cold water circuit inlet or
3
connection for more boilers
4 Outlet for condense
A
H5 (6)
H
CYLINDERS - PUFFER
6 Steam circuit inlet
MULTIFUEL ENERGY
H4 (5)
7 Connection for instrumentation 1/2” F
HYDRONIC
Connection for recirculation or for domestic hot
11-13
water
12 Connection for instrumentation 1/2" F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
(14)
(1) (2) (11) (3) (13)
H1 (15) 14 Domestic hot water outlet
15 Drain 1” F (only for models > 1500)
INERTIAL
TANKS
Models from 1500 to 5000 have two
gripps on the bottom which allow the use
(4) (5) (6) (15) of forklift when handling and drain pipe
already fitted.
WATER PRESSURE
TANKS
HARD FOAM INSULATION (WXB)
2-3
Volume Weight De H A H1 H2 H3 H4 H5 H6 H7 H15 H16 H17 5 4-6 14
Model 11-13
COMPRESSED AIR
500 500 99 750 1800 1950 85 375 410 460 510 570 760 // 1329 1485 Øe 300 1"1/4 DN25 PN16 1”1/4
800 794 161 900 2135 2320 85 405 450 540 630 690 870 // 1610 1765 Øe 380 1"1/4 DN50 PN16 1”1/4
1000 1042 204 1000 2221 2436 105 458 503 593 683 743 993 // 1664 1818 Øe 380 1"1/2 DN50 PN16 1”1/4
1500 1445 250 1100 2415 2654 109 440 485 575 665 725 1075 // 1895 2050 Øe 380 1"1/2 DN50 PN16 1"1/2
2000 1977 288 1300 2492 2811 91 467 602 692 782 867 842 1952 1877 2057 Øe 380 2" DN50 PN16 2"
AND SPARE PARTS
ACCESORIES
2000 1977 288 1360 2492 2560 91 467 602 692 782 867 842 1952 1877 2057 Øe 380 1"1/2 DN50 PN16 1"1/2
2500 2312 331 1350 2311 2470 140 551 686 776 866 951 976 1816 1732 1891 Øe 380 2" DN50 PN16 2"
3000 2918 377 1350 2811 2940 140 551 686 776 866 951 1036 2316 2232 2391 Øe 380 2" DN50 PN16 2"
4000 3769 530 1500 2875 3040 114 570 690 795 900 970 1035 2315 2238 2410 Øe 380 2" DN50 PN16 2"
5000 4982 663 1700 2915 3120 94 580 700 805 910 980 1035 2335 2265 2420 Øe 430 2" DN50 PN16 2"
39
EXTRA 2 VAPORE
POLYWARM® COATED CALORIFIERS WITH 2 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGERS
FOR STEAM GENERATOR
APPLICATION DRAIN
Production and storage of sanitary hot water. Suitable for steam External confluence through drain connection.
generators. GASKET- FLANGE PLATE
MATERIAL Asbestos-free fiber gaskets
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Mild steel exchanger head with anticorrosion treatment.
- UBA - WRAS) WARRANTY
HEAT EXCHANGER 5 years - See general sales conditions and warranty
2 stainless steel 316L straight heat exchangers suitable for steam ACCESSORIES AND SPARE PARTS
power. See Accessories section for the entire list
INSULATION (DISMOUNTABLE)
NOFIRE® polyester fleece 100% made of recyclable material, with
high thermal insulation. Fire resistance class B-s2d0 according to EN
13501. Grey PVC external lining.
CATHODE PROTECTION
2 magnesium anodes.
POLYWARM®
SOFT FLEECE INSULATION
STAINLESS STEEL
EXTRA 2 VAPORE WXC HEAT EXCHANGER SURFACE
DISMOUNTABLE SOFT FLEECE Lower Upper
Model insulation
Art. Nr. [m2]
3000 3069162363008 3 3
4000 3069162363009 4 4
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
5000 3069162363010 5 5
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5032240000107 Art. Nr. Model
5005000310002 WXC
5 units box 5200000000013 3000÷5000
40
EXTRA 2 VAPORE
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 2 STAINLESS STEEL EXTRACTABLE HEAT EXCHANGERS
FOR STEAM GENERATOR
STORAGE HEAT EXCHANGER
Pmax Tmax Pmax Tmax
6 bar 90 °C 6 bar 165 °C
BOLLYTERM®
CALORIFIERS
De
STAINLESS STEEL
CALORIFIERS
(18)
CALORIFIERS FOR
H16 (14)
HEAT PUMP
H15 (13) Alternative domestic cold water circuit inlet or
3
connection for more boilers
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H7 (8)
H
H1 (1)
HYDRONIC
13 Connection for 2nd anode 1”1/4 Gas F
0
14 Connection for electrical immersion 2” Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
(18)
(1) (2) (15) (3) (17) H1 (15)
WATER PRESSURE
(7) (12) (14) (16) (8) (13)
TANKS
Tanks have two gripps on the bottom
which allow the use of forklift when
handling and drain pipe already fitted.
(4) (5) (6) (9) (10)
(11) (15)
COMPRESSED AIR
RECEIVERS
Volume Weight De H A H1 H2 H3 H4 H5 H6 H7
Model
[litres] [Kg] [mm]
AND SPARE PARTS
ACCESORIES
3000 2923 440 1350 2811 3076 140 551 686 776 866 951 1036
4000 3776 620 1500 2875 3198 114 570 690 795 900 970 1035
5000 4990 763 1700 2915 3325 94 580 700 805 910 980 1035
2-3 4-6
H8 H9 H10 H11 H15 H16 H17 5 10 7-12-16 8-13 21
Model 15-17-18 9-11
TECHNICAL
SUPPORT
41
EXTRA1 PLUS
POLYWARM® COATED CALORIFIERS WITH 1 EXTRACTABLE FINNED COPPER HEAT EXCHANGER
POLYWARM®
ENERGY
EXTRA 1 PLUS WRB EFFICIENCY
CLASS
HEAT EXCHANGER
SURFACE
HARD FOAM
insulation ErP
HARD FOAM INSULATION
Model
Art. Nr. [m2]
200 3074162352302 0,76 C
300 3074162352303 0,94 C
500 3074162352304 1,58 C
800 3074162352305 2,63 C
1000 3074162352306 3,17 C
1500 3074162352307 4,54 C
2000 3074162352308 5,26 C
ENERGY
EXTRA 1 PLUS WRC EFFICIENCY
CLASS
HEAT EXCHANGER
SURFACE
www.cordivari.com/erp DISMOUNTABLE SOFT FLEECE
Model insulation ErP
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5005000310002 WRC 5032240000107 Art. Nr. Model
5005000310003 WRB 5 units box 5200000000008 200, 300
5200000000009 500, 800
5200000000011 1000, 1500
5200000000013 2000÷5000
42
EXTRA1 PLUS
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 EXTRACTABLE FINNED COPPER HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
1500 ÷ 5000 6 bar indicated by Ecodesign ErP Directive.
STAINLESS STEEL
De
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
(14) DATA RESULTS
H17 (11)
(12) (13)
CALORIFIERS FOR
H16 (10)
HEAT PUMP
H15 (9)
Drain 1” 1/4 Gas F
1
For model 1000 connection 1”1/2 Gas F
2 Domestic cold water circuit inlet
A
3
connection for more boilers
H7 (8)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H6 (7) 4 Primary circuit outlet
H4 (5) (6) 5 Heat exchanger flange
(4)
H2 (2) (3) 6 Primary circuit inlet
7 Connection for instrumentation 1/2" Gas F
8 Connection for magnesium anode 1" 1/4 Gas F
H1 (1)
0 Connection for 2nd anode 1"1/4 Gas F (only for models
9
HYDRONIC
> 1500)
Connection for electrical immersion 1" 1/2 Gas F
10
For models > 800 connection 2" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
14 Domestic hot water outlet
TANKS
Models from 1500 to 5000 have two
(7) (10) (12) gripps on the bottom which allow 15 Drain 1" Gas F (only for models > 1000)
(8) (9) the use of forklift when handling and
drain pipe already fitted.
(4) (5) (6) (15)
WATER PRESSURE
TANKS
HARD FOAM INSULATION (WRB)
2-3
Volume De H A H1 H2 H4 H6 H7 H15 H16 H17 5 14
Model 11-13
[litres] [mm] Connections Gas F
200 191 550 1449 1550 85 325 410 520 650 // 1075 1185 Øe 300 1"1/4 1"1/4
COMPRESSED AIR
300 292 650 1499 1634 85 350 435 545 735 // 1100 1210 Øe 300 1"1/4 1"1/4
RECEIVERS
500 500 750 1800 1950 85 375 460 570 760 // 1329 1485 Øe 300 1"1/4 1"1/4
800 791 900 2135 2317 85 405 490 600 870 // 1610 1765 Øe 300 1"1/4 1"1/4
1000 1040 1000 2221 2436 105 458 543 653 993 // 1664 1818 Øe 300 1"1/2 1"1/2
1500 1442 1100 2415 2654 109 440 525 635 1075 // 1895 2050 Øe 300 1"1/2 2"
2000 1974 1300 2492 2811 91 467 542 652 842 1952 1877 2057 Øe 300 2" 2"
AND SPARE PARTS
ACCESORIES
2000 1974 1360 2492 2560 91 467 542 652 842 1952 1877 2057 Øe 300 2" 2"
2500 2310 1350 2311 2470 140 551 626 736 976 1816 1732 1891 Øe 300 2" 2"
3000 2916 1350 2811 2940 140 551 626 736 876 2316 2232 2391 Øe 300 2" 2"
4000 3764 1500 2875 3040 114 570 645 755 895 2315 2238 2410 Øe 300 2" 2"
5000 4978 1700 2915 3120 94 580 655 765 935 2335 2265 2420 Øe 300 2" 2"
43
EXTRA1PLUS - HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C
and output 45°C;
4) Sanitary water according to UNI CTI 8065.
450
3,17
Heat exchanger surface [m2]
400
4000
200 0,76
300 0,94 350
2,63
500 1,58 2,27
300 3000
800 2,63
[mm.H2O]
[mbar]
150
100
0,76
1000
50
0 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
44
EXTRA- BOLLY®
EXTRA1 PLUS - HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
STAINLESS STEEL
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
CALORIFIERS
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
211 266 286 307 320 409 502 605 1,4 895 87,8
210 272 281 300 312 438 481 570 0,7 223 21,9
313 406 418 445 449 630 690 816 1,4 1936 189,9
312 402 413 436 440 610 664 775 0,7 484 47,5
547 706 725 765 767 1063 1155 1350 1,4 1861 182,5
543 696 712 746 746 1019 1096 1259 0,7 465 45,6
CALORIFIERS FOR
896 1153 1182 1243 1252 1723 1864 2157 1,4 3097 303,7
HEAT PUMP
887 1134 1158 1207 1210 1634 1748 1980 0,7 774 75,9
1158 1486 1519 1590 1581 2158 2321 2659 1,4 3733 366,1
1147 1462 1489 1543 1528 2045 2174 2436 0,7 933 91,5
1622 2087 2140 2251 2248 3097 3349 3883 3 2878 282,2
1608 2058 2101 2191 2182 2955 3164 3596 1,5 720 70,6
2185 2799 2859 2983 2903 3952 4237 4836 3 2878 282,2
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2169 2763 2812 2911 2823 3780 4012 4490 1,5 720 70,6
2496 3197 3266 3410 3350 4559 4890 5581 3 4588 449,9
2474 3151 3206 3319 3248 4339 4603 5143 1,5 1147 112,5
3189 4064 4133 4277 4044 5426 5757 6448 3 5530 542,3
3168 4018 4073 4186 3941 5207 5471 6011 1,5 1382 135,5
4002 5080 5149 5293 4856 6441 6773 7464 3 5530 542,3
3981 5034 5089 5202 4754 6222 6486 7026 1,5 1382 135,5
5193 6568 6637 6781 6047 7930 8261 8952 3 5530 542,3
HYDRONIC
5172 6523 6578 6690 5945 7711 7975 8515 1,5 1382 135,5
INERTIAL
8000
TANKS
6,34
700
7000
WATER PRESSURE
5,26
600
6000
TANKS
4,54
5000 500
Heat exchanger surface [m2]
[mm.H2O]
COMPRESSED AIR
1500 4,54
RECEIVERS
2000 5,26
[mbar]
4000 400
2500 6,34
3000 6,34
4000 6,34 3000 300
5000 6,34
AND SPARE PARTS
ACCESORIES
2000 200
1000 100
TECHNICAL
SUPPORT
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4
Flow Rate [m3/h]
45
EXTRA 2 PLUS
POLYWARM® COATED CALORIFIERS WITH 2 EXTRACTABLE FINNED COPPER HEAT EXCHANGERS
POLYWARM®
ENERGY
EXTRA 2 PLUS WRB HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM INSULATION
www.cordivari.com/erp ENERGY
EXTRA 2 PLUS WRC HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
On line ErP label tool
DISMOUNTABLE SOFT FLEECE
SOFT FLEECE INSULATION
Lower Upper
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Model insulation ErP
Art. Nr. [m2]
500 3082162352333 1,58 0,76 C
800 3082162352334 2,63 0,94 C
1000 3082162352335 3,17 1,58 C
1500 3082162352336 4,54 2,63 C
2000 3082162352337 5,26 3,17 C
2500 3082162352313 6,34 4,54
3000 3082162352309 6,34 5,26
4000 3082162352310 6,34 6,34
5000 3082162352312 6,34 6,34
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5005000310002 WRC 5032240000107 Art. Nr. Model
5005000310003 WRB 5 units box 5200000000008 200, 300
5200000000009 500, 800
5200000000011 1000, 1500
5200000000013 2000÷5000
46
EXTRA 2 PLUS
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 2 EXTRACTABLE FINNED COPPER HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
1500 ÷ 5000 6 bar indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
(18) CERTIFIED LABORATORIES
DATA RESULTS
Drain 1” 1/4 Gas F
1
For model 1000 connection 1”1/2 Gas F
H17 (15)(1 2 Domestic cold water circuit inlet
Alternative domestic cold water circuit inlet or connection
CALORIFIERS FOR
H16(14) 3
for more boilers
HEAT PUMP
H15 (13)
4 Lower heat exchanger outlet
(11)
(9) 5 Heat exchanger flange Lower Øe 300
H11(12) 6 Lower heat exchanger inlet
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H7 (8) (6) 9 Upper heat exchanger outlet
(4) 10 Heat exchanger flange Upper Øe 300
H6 (7)
11 Upper heat exchanger inlet
H4 (5) 12 16 Connection for instrumentation 1/2" Gas F
H2(2)(3) Connection for 2nd anode 1"1/4 Gas F (only for models >
13
1500)
Connection for electrical immersion 1"1/2 Gas F
14
H1 (1) For models > 800 connection 2" Gas F
HYDRONIC
0 15
Connection for recirculation or for domestic hot water
17
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
(18)
TANKS
(1) (2) (15) (3) (17)
WATER PRESSURE
the use of forklift when handling and
(4) (5) (6) (9) (10) H1 (21)
drain pipe already fitted.
TANKS
(11) (21)
200 193 550 1449 1550 85 325 410 520 650 860 970 // 1075 1185 1"1/4 1"1/4
300 295 650 1499 1635 85 350 435 545 735 885 995 // 1100 1210 1"1/4 1"1/4
500 503 750 1800 1950 85 375 460 570 760 910 1020 // 1329 1485 1"1/4 1"1/4
800 794 900 2135 2320 85 405 490 600 870 1090 1200 // 1610 1765 1"1/4 1"1/4
1000 1043 1000 2221 2436 105 458 543 653 993 1143 1253 // 1664 1818 1"1/2 1"1/2
1500 1445 1100 2415 2654 109 440 525 635 1075 1250 1360 // 1895 2050 1"1/2 2"
2000 1977 1300 2492 2811 91 467 542 652 842 1262 1372 1952 1877 2057 2" 2"
AND SPARE PARTS
ACCESORIES
2000 1977 1360 2492 2560 91 467 542 652 842 1262 1372 1952 1877 2057 2" 2"
2500 2313 1350 2311 2470 140 551 626 736 876 1201 1311 1816 1732 1891 2" 2"
3000 2919 1350 2811 2940 140 551 626 736 876 1476 1586 2316 2232 2391 2" 2"
4000 3767 1500 2875 3040 114 570 645 755 895 1495 1605 2315 2238 2410 2" 2"
5000 4981 1700 2915 3120 94 580 655 765 935 1505 1615 2335 2265 2420 2" 2"
47
EXTRA2 PLUS - HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
48
EXTRA- BOLLY®
EXTRA2 PLUS - HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
138 175 194 215 247 318 411 513 1,4 895 87,8
137 181 190 208 239 347 389 479 0,7 223 21,9
CALORIFIERS FOR
198 249 268 290 306 392 485 587 1,4 895 87,8
HEAT PUMP
196 255 264 283 298 421 463 553 0,7 223 21,9
351 441 460 481 459 584 676 779 1,4 895 87,8
349 447 455 474 451 612 655 744 0,7 223 21,9
589 750 763 789 724 974 1034 1160 1,4 1936 189,9
587 746 757 781 716 955 1008 1119 0,7 484 47,5
744 951 970 1011 963 1309 1401 1596 1,4 1861 182,5
CYLINDERS - PUFFER
MULTIFUEL ENERGY
739 942 958 992 943 1264 1342 1504 0,7 465 45,6
1033 1324 1354 1415 1389 1894 2035 2329 1,4 3097 303,7
1024 1306 1329 1378 1347 1805 1919 2152 0,7 774 75,9
1422 1816 1849 1920 1845 2488 2651 2989 1,4 3733 366,1
1411 1792 1819 1873 1792 2375 2504 2766 0,7 933 91,5
1472 1900 1953 2064 2098 2909 3162 3696 3 2878 282,2
1458 1870 1914 2004 2032 2768 2977 3409 1,5 720 70,6
2081 2669 2729 2853 2799 3822 4107 4706 3 2878 282,2
2065 2633 2682 2781 2719 3650 3882 4360 1,5 720 70,6
HYDRONIC
2657 3398 3467 3611 3511 4760 5091 5782 3 5530 542,3
2636 3353 3408 3520 3409 4541 4805 5345 1,5 1382 135,5
3441 4378 4447 4591 4295 5740 6071 6762 3 5530 542,3
3420 4333 4388 4500 4193 5521 5785 6325 1,5 1382 135,5
INERTIAL
TANKS
WATER PRESSURE
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
TANKS
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
211 266 286 307 320 409 502 605 1,4 895 87,8
210 272 281 300 312 438 481 570 0,7 223 21,9
COMPRESSED AIR
313 406 418 445 449 630 690 816 1,4 1936 189,9
RECEIVERS
312 402 413 436 440 610 664 775 0,7 484 47,5
547 706 725 765 767 1063 1155 1350 1,4 1861 182,5
543 696 712 746 746 1019 1096 1259 0,7 465 45,6
896 1153 1182 1243 1252 1723 1864 2157 1,4 3097 303,7
887 1134 1158 1207 1210 1634 1748 1980 0,7 774 75,9
1158 1486 1519 1590 1581 2158 2321 2659 1,4 3733 366,1
AND SPARE PARTS
1147 1462 1489 1543 1528 2045 2174 2436 0,7 933 91,5
ACCESORIES
1622 2087 2140 2251 2248 3097 3349 3883 3 2878 282,2
1608 2058 2101 2191 2182 2955 3164 3596 1,5 720 70,6
2185 2799 2859 2983 2903 3952 4237 4836 3 2878 282,2
2169 2763 2812 2911 2823 3780 4012 4490 1,5 720 70,6
2496 3197 3266 3410 3350 4559 4890 5581 3 4588 449,9
2474 3151 3206 3319 3248 4339 4603 5143 1,5 1147 112,5
3189 4064 4133 4277 4044 5426 5757 6448 3 5530 542,3
TECHNICAL
3168 4018 4073 4186 3941 5207 5471 6011 1,5 1382 135,5
SUPPORT
4002 5080 5149 5293 4856 6441 6773 7464 3 5530 542,3
3981 5034 5089 5202 4754 6222 6486 7026 1,5 1382 135,5
5193 6568 6637 6781 6047 7930 8261 8952 3 5530 542,3
5172 6523 6578 6690 5945 7711 7975 8515 1,5 1382 135,5
49
EXTRA 3 PLUS
POLYWARM® COATED CALORIFIERS WITH 3 EXTRACTABLE FINNED COPPER HEAT EXCHANGERS
POLYWARM®
HARD FOAM INSULATION
ENERGY
EXTRA 3 PLUS WRB HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM Lower Middle Upper ErP
Model insulation
Art. Nr. [m ]
2
www.cordivari.com/erp
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
EXTRA 3 PLUS WRC HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE
insulation Lower Middle Upper ErP
Model
Art. Nr. [m ]
2
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5005000310002 WRC 5032240000107 Art. Nr. Model
5005000310003 WRB 5 units box 5200000000011 1500
5200000000013 2000÷5000
50
EXTRA 3 PLUS
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 3 EXTRACTABLE FINNED COPPER HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
De
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
(21) DATA RESULTS
CALORIFIERS FOR
(16) (17) (18)
HEAT PUMP
2 Domestic cold water circuit inlet
H15 (13) (20) Alternative domestic cold water circuit inlet or
H13 (14) (19) 3
connection for more boilers
4 Lower heat exchanger outlet
H11 (12) 5 Lower heat exchanger flange Øe 300
6 Lower heat exchanger inlet
A
CYLINDERS - PUFFER
(11)
MULTIFUEL ENERGY
H9 (10) (9) 7 Connection for instrumentation 1/2" Gas F
H
HYDRONIC
14 Upper heat exchanger flange Øe 300
H1 (1) 15
Connection for recirculation or for domestic hot water
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
0 18
16
Connection for instrumentation 1/2" Gas F
17
19 Upper heat exchanger outlet
INERTIAL
20 Upper heat exchanger inlet
TANKS
(21) 21 Domestic hot water outlet 2” Gas F
(1) (2) (15) (3) (18)
WATER PRESSURE
(7) (12) (16) (8) (13) (17)
when handling and drain pipe already
fitted.
TANKS
(4) (5) (6) (9) (10)
(11) (14) (19) (20)
COMPRESSED AIR
RECEIVERS
3000 2922 377 1350 2811 2940 140 551 626 736 876 1476 1586 2176 1926 2391 2"
4000 3770 504 1500 2875 3040 114 570 645 755 895 1495 1605 2175 1895 2410 2"
5000 4984 634 1700 2915 3120 94 580 655 765 935 1505 1615 2185 1855 2420 2"
51
EXTRA3 PLUS - HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C
and output 45°C;
4) Sanitary water according to UNI CTI 8065.
52
EXTRA3 PLUS - HEAT EXCHANGERS TECHNICAL DATA
EXTRA- BOLLY®
CALORIFIERS
BOLLYTERM®
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
STAINLESS STEEL
storage at t2 and primary at T1 storage at t2 and primary at T1
CALORIFIERS
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
519 681 711 772 875 1251 1392 1686 1,4 1861 182,5
510 663 687 735 833 1163 1276 1509 0,7 465 45,6
787 1021 1055 1126 1210 1694 1856 2195 1,4 3097 303,7
776 998 1025 1079 1157 1581 1710 1971 0,7 774 75,9
893 1176 1228 1340 1518 2185 2438 2972 1,4 3097 303,7
CALORIFIERS FOR
879 1146 1190 1280 1453 2044 2252 2684 0,7 774 75,9
HEAT PUMP
1061 1393 1453 1578 1778 2546 2832 3430 3 2878 282,2
1044 1358 1406 1506 1698 2374 2606 3084 1,5 720 70,6
1370 1790 1859 2003 2224 3151 3483 4174 3 2878 282,2
1349 1744 1799 1912 2122 2932 3196 3736 1,5 720 70,6
2033 2618 2687 2831 2887 3980 4311 5002 3 2878 282,2
2012 2573 2628 2740 2785 3761 4025 4565 1,5 720 70,6
CYLINDERS - PUFFER
MULTIFUEL ENERGY
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
HYDRONIC
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
1033 1324 1354 1415 1389 1894 2035 2329 1,4 3097 303,7
1024 1306 1329 1378 1347 1805 1919 2152 0,7 774 75,9
1422 1816 1849 1920 1845 2488 2651 2989 3 2878 282,2
1411 1792 1819 1873 1792 2375 2504 2766 1,5 720 70,6
1472 1900 1953 2064 2098 2909 3162 3696 3 2878 282,2
INERTIAL
TANKS
1458 1870 1914 2004 2032 2768 2977 3409 1,5 720 70,6
2081 2669 2729 2853 2799 3822 4107 4706 3 2878 282,2
2065 2633 2682 2781 2719 3650 3882 4360 1,5 720 70,6
2657 3398 3467 3611 3511 4760 5091 5782 3 2878 282,2
2636 3353 3408 3520 3409 4541 4805 5345 1,5 720 70,6
3441 4378 4447 4591 4295 5740 6071 6762 3 5530 542,3
WATER PRESSURE
3420 4333 4388 4500 4193 5521 5785 6325 1,5 1382 135,5
TANKS
COMPRESSED AIR
RECEIVERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
1622 2087 2140 2251 2248 3097 3349 3883 3 2878 282,2
1608 2058 2101 2191 2182 2955 3164 3596 1,5 720 70,6
AND SPARE PARTS
2185 2799 2859 2983 2903 3952 4237 4836 3 2878 282,2
ACCESORIES
2169 2763 2812 2911 2823 3780 4012 4490 1,5 720 70,6
2496 3197 3266 3410 3350 4559 4890 5581 3 4588 449,9
2474 3151 3206 3319 3248 4339 4603 5143 1,5 1147 112,5
3189 4064 4133 4277 4044 5426 5757 6448 3 5530 542,3
3168 4018 4073 4186 3941 5207 5471 6011 1,5 1382 135,5
4002 5080 5149 5293 4856 6441 6773 7464 3 5530 542,3
3981 5034 5089 5202 4754 6222 6486 7026 1,5 1382 135,5
TECHNICAL
SUPPORT
5193 6568 6637 6781 6047 7930 8261 8952 3 5530 542,3
5172 6523 6578 6690 5945 7711 7975 8515 1,5 1382 135,5
53
EXTRA PLUS - PRESSURE LOSS - COPPER FINNED AND TINNED HEAT EXCHANGERS
Flow Rate [lt/min]
Heat exchanger surface [m2]
0 5 10 15 20 25
200 0,76 5000
1500 4,54
300
2000 5,26
[mbar]
3000
[mm H2O]
2500 6,34 2500 250
0,76 m2
1000 100
500 50
450
4500
3,17 m2
400
4000
2,63 m 2
350
3500
2,27 m 2
300
3000
[mm H2O]
[mbar]
2500 250
2000 200
1500 150
1000 100
500 50
6,34
700
7000
5,26
600
6000
4,54
500
[mm H2O]
5000
4000 400
[mbar]
3000 300
2000 200
1000 100
54
EXTRA PLUS - HEAT EXCHANGERS OUTPUT CHART
EXTRA- BOLLY®
CALORIFIERS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
BOLLYTERM®
CALORIFIERS
60
2,63 m 2
50
STAINLESS STEEL
CALORIFIERS
40
1,58 m 2
Output [kW]
CALORIFIERS FOR
30
HEAT PUMP
0,94 m 2
20
CYLINDERS - PUFFER
MULTIFUEL ENERGY
0,76 m 2
10
0
55 60 65 70 75 80
HYDRONIC
Primary circuit temperature [°C]
INERTIAL
TANKS
200
180
WATER PRESSURE
160
TANKS
6,34 m 2
140
120 5,26 m 2
Output [kW]
COMPRESSED AIR
100
RECEIVERS
4,54 m 2
80
3,17 m 2
60
AND SPARE PARTS
40
ACCESORIES
20
0
55 60 65 70 75 80
TECHNICAL
55
EXTRA - MODELS AVAILABLE ON REQUEST
For your comfortable choice, Cordivari offers the possibility to realize special customized products.
Below you find a list of common requested customized Extra calorifiers and relevant pricelist.
56
EXTRA- BOLLY®
EXTRA - MODELS AVAILABLE ON REQUEST
CALORIFIERS
EXTRA 3 WXC
(POLYWARM® CALORIFIER / STAINLESS STEEL HEAT EXCHANGER) - WITH UPPER BLIND FLANGE
BOLLYTERM®
Calorifier Flange Heat exchanger Heat exchanger Heat exchanger
CALORIFIERS
diameter diameter surface 1 surface 2 surface 3
Model BLIND
[mm] [mm] [m2] [m2] [m2] FLANGE
1500 950(D) 300-380 3 3 Blind flange
STAINLESS STEEL
CALORIFIERS
3000 1250 (D) 350-430 6 6 Blind flange
CALORIFIERS FOR
EXTRA 3 WXC
HEAT PUMP
(POLYWARM® CALORIFIER / STAINLESS STEEL HEAT EXCHANGER) - WITH UPPER AND MIDDLE
BLIND FLANGE
Calorifier Flange Heat exchanger Heat exchanger Heat exchanger
Model diameter diameter surface 1 surface 2 surface 3
BLIND
CYLINDERS - PUFFER
MULTIFUEL ENERGY
[mm] [mm] [m2] [m2] [m2] FLANGE
1500 950 300-380 3 Blind flange Blind flange BLIND
2000 1100 350-430 4 Blind flange Blind flange
FLANGE
HYDRONIC
EXTRA 3 WXC
(POLYWARM® CALORIFIER / STAINLESS STEEL HEAT EXCHANGER) - WITH MIDDLE BLIND FLANGE
INERTIAL
TANKS
Calorifier Flange Heat exchanger Heat exchanger Heat exchanger
Model diameter diameter surface 1 surface 2 surface 3
[mm] [mm] [m2] [m2] [m2]
WATER PRESSURE
2000 1100 350-430 4 Blind flange 2
TANKS
3000 1250 350-430 6 Blind flange 3
57
VASO INERZIALE
POLYWARM® COATED DOMESTIC HOT WATER ACCUMULATION TANK
APPLICATION DRAIN
Domestic hot water storage. External confluence through drain connection.
MATERIAL Models > 1000 external confluence through drain pipe.
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 GASKET- FLANGE PLATE
- UBA - WRAS) Silicone gaskets suitable for alimentary use for max temperature up
INSULATION to 200°C. Mild steel inspection flange plate with Polywarm®
- HARD: High thermal insulation with ecological polyurethane hard foam. WARRANTY
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, 5 years - See general sales conditions and warranty
with high thermal insulation. Fire resistance class B-s2d0 according ACCESSORIES AND SPARE PARTS
to EN 13501. See Accessories section for the entire list.
Grey PVC external lining complete with top and flange cover
CATHODE PROTECTION
Magnesium anode. Models > 1500 n° 2 magnesium anode.
POLYWARM®
S T O C K
AVAILABILITY
grey
ENERGY
VASO INERZIALE WB EFFICIENCY
CLASS
HARD FOAM
Model insulation ErP
HARD FOAM INSULATION
Art. Nr.
200 3060162310102 C
300 3060162310103 C
500 3060162310104 C
800 3060162310105 C
1000 3060162310106 C
1500 3060162310107 C
2000 3060162310108 C
ENERGY
VASO INERZIALE WC EFFICIENCY
www.cordivari.com/erp CLASS
DISMOUNTABLE SOFT FLEECE
On line ErP label tool insulation ErP
SOFT FLEECE INSULATION
Model
Art. Nr.
500 3060161620134 C
800 3060161620135 C
1000 3060161620136 C
1500 3060161620137 C
2000 3060161620138 C
2500 3060161620113
3000 3060161620109
4000 3060161620110
5000 3060161620112
58
VASO INERZIALE
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER ACCUMULATION TANK
STORAGE T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
Model Pmax Tmax that test procedures and
200 ÷ 1000 8 bar Cordivari LAB are certified conforming
90 °C
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
1500 ÷ 5000 6 bar indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
(14)
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
COMPLETE YOUR 2 Domestic cold water circuit inlet
HEAT PUMP
SYSTEM WITH THE
NEW PRS MODULE 3 Delivery to external heat exchanger
(FOR IMMEDIATE DHW 5 Blind flange for inspection Øe 300
PREPARATION)
7 Connection for instrumentation 1/2" Gas F
H7 (8) 8 Connection for magnesium anode 1”1/4 Gas F
H6 (7)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Connection for 2nd anode 1”1/4 Gas F
H4 (5) 9
(for models > 1500)
Connection for electrical immersion 1” 1/2 Gas F
H2 (2) (3) 10
For models > 800 connection 2" Gas F
11 Recirculation
HYDRONIC
SEE HYDRONIC 14 Domestic hot water outlet
SECTION
15 Drain 1” Gas F (only for models > 1000)
(14)
(1) (2) (11) (3) (13)
Models from 1500 to 5000 have two
gripps on the bottom which allow
INERTIAL
the use of forklift when handling and
TANKS
H1 (15) drain pipe already fitted.
(7) (10) (12) (8) (9)
(5)
WATER PRESSURE
TANKS
HARD FOAM INSULATION (WB)
2-3
Volume Weight De H A H1 H2 H4 H6 H7 H15 H16 H17 14
Model 11-13
[litres] [kg] [mm] Connections Gas F
200 192 41 550 1449 1550 85 325 410 520 650 // 1075 1185 1"1/4 1"1/4
300 293 52 650 1499 1634 85 350 435 545 735 // 1100 1210 1"1/4 1"1/4
COMPRESSED AIR
500 501 69 750 1800 1950 85 375 460 570 760 // 1329 1485 1"1/4 1"1/4
RECEIVERS
800 792 111 900 2135 2317 85 405 490 600 870 // 1610 1765 1"1/4 1"1/4
1000 1041 150 1000 2221 2436 105 458 543 653 993 // 1664 1818 1"1/2 1"1/2
1500 1443 186 1100 2415 2654 109 440 525 635 1075 // 1895 2050 1"1/2 2"
2000 1975 223 1300 2492 2811 91 467 542 652 842 1952 1877 2057 2" 2"
AND SPARE PARTS
ACCESORIES
2000 1975 223 1360 2492 2560 91 467 542 652 842 1952 1877 2057 2" 2"
2500 2311 267 1350 2311 2470 140 551 626 736 976 1816 1732 1891 2" 2"
3000 2917 313 1350 2811 2940 140 551 626 736 876 2316 2232 2391 2" 2"
4000 3765 435 1500 2875 3040 114 570 645 755 895 2315 2238 2410 2" 2"
5000 4979 558 1700 2915 3120 94 580 655 765 935 2335 2265 2420 2" 2"
59
VASO INERZIALE COMPACT
POLYWARM® COATED DOMESTIC HOT WATER ACCUMULATION TANK
APPLICATION DRAIN
Domestic hot water storage. Suitable for low-ceilinged room. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm®
INSULATION (DISMOUNTABLE) WARRANTY
NOFIRE® polyester fleece 100% made of recyclable material, with 5 years - See general sales conditions and warranty
high thermal insulation. Fire resistance class B-s2d0 according to EN ACCESSORIES AND SPARE PARTS
13501. See Accessories section for the entire list.
Grey PVC external lining complete with top and flange cover
CATHODE PROTECTION
2 magnesium anodes.
POLYWARM®
SOFT FLEECE INSULATION
ENERGY
VASO INERZIALE COMPACT WC EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE
Model insulation ErP
Art. Nr.
1500 3060161620147 C
2000 3060161620148 C
2500 3060161620149
3000 3060161620150
4000 3060161620151
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5032240000107 Art. Nr. Model
5005000310002 WC
5 units box 5200000000011 1500
5200000000013 2000÷4000
60
VASO INERZIALE COMPACT
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER ACCUMULATION TANK
STORAGE T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
Pmax Tmax that test procedures and
6 bar 90 °C Cordivari LAB are certified conforming SUITABLE FOR
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive. LOW-CEILINGED ROOMS
MAX HEIGHT
250 cm
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(14)
CALORIFIERS FOR
HEAT PUMP
1 Drain 1” Gas F
2 Domestic cold water circuit inlet
H
CYLINDERS - PUFFER
5 Heat exchanger flange
MULTIFUEL ENERGY
H4 (5) 7 Connection for instrumentation 1/2" Gas F
HYDRONIC
13
12 Connection for instrumentation 1/2" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
(7) (10) (12) (8) (9)
TANKS
(5)
WATER PRESSURE
The calorifier has two gripps on the bottom
TANKS
which allows the use of forklift when handling
and already equipped with mounted drainage
H1 (15) tube.
COMPRESSED AIR
RECEIVERS
Volume Weight De Df H A H1 H2 H4
Model
[lt] [kg] [mm]
1500 1506 221 1360 1100 1992 2094 91 467 542
2000 2012 300 1510 1250 2111 2241 140 551 628
2500 2627 393 1500 1400 2125 2353 114 570 645
AND SPARE PARTS
3000 3029 472 1600 1500 2140 2400 109 575 650
ACCESORIES
2-3
H6 H7 H15 H16 H17 5 4-6 7-12 8 9
Model 11-13
[mm] Connections Gas F
1500 652 942 // 1377 1557 Øe 300 2" 2" 1/2" 1"1/4 //
TECHNICAL
SUPPORT
2000 738 978 1566 1484 1643 Øe 300 2" 2" 1/2" 1"1/4 1"1/4
2500 755 975 1585 1488 1660 Øe 300 2" 2" 1/2" 1"1/4 1"1/4
3000 760 980 1600 1520 1675 Øe 300 2" 2" 1/2" 1"1/4 1"1/4
4000 765 1015 1855 1765 1920 Øe 300 2" 2" 1/2" 1"1/4 1"1/4
61
PIASTRATERM® SLB
POLYWARM® COATED DOMESTIC HOT WATER ACCUMULATION TANK
WITH STAINLESS STEEL BRAZED PLATE HEAT EXCHANGER
POLYWARM®
www.cordivari.com/erp
On line ErP label tool
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
500 Art. Nr. 3170161722121 3170161722122 3170161722123 3170161722124 3170161722125 C
3170161721038
800 Art. Nr. 3170161722132 3170161722133 3170161722134 C
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5032240000107 Art. Nr. Model
5005000310003 WB
5 units box 5200000000008 200, 300
5200000000009 500, 800
5200000000011 1000, 1500
5200000000013 2000
62
PIASTRATERM® SLB
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER ACCUMULATION TANK
WITH STAINLESS STEEL BRAZED PLATE HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
200 ÷ 1000 8 bar
90 °C 10 bar 99 °C 30 °f
1500 ÷ 2000 6 bar
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
STAINLESS STEEL
Cordivari LAB are certified conforming
CALORIFIERS
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
De
Df
(14) Drain 1” 1/4 Gas F.
1
For model 1000 connection 1”1/2 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2 Domestic cold water circuit inlet
Alternative Sanitary water inlet
3
(11) H17 (12) (13) or connection for more boilers
HYDRONIC
(only for models > 1500)
H
H6 (7)
11 Entry heating water from the buffer 1” 1/4 Gas F
H4 (5) 12 Connection for instrumentation 1/2" Gas F
H2 (2) (3) 13 Recirculation
INERTIAL
14 Domestic hot water outlet
TANKS
15 Drain 1” Gas F (for models > 1000)
H1 (1) 16 Heating water back to the buffer 1” 1/4 Gas F
0
WATER PRESSURE
Models from 1500 to 5000 have two
TANKS
(1) (2) gripps on the bottom which allow
(14)
(11) (16) (3) (13) the use of forklift when handling and
drain pipe already fitted.
H1 (15)
(5) (15)
AND SPARE PARTS
ACCESORIES
2-3
Volume De H A H1 H2 H4 H6 H7 H15 H16 H17 14
Model 13
[litres] [mm] Connections Gas F
200 192 550 1449 1550 85 325 410 520 650 // 1075 1185 1"1/4 1"1/4
300 293 650 1499 1634 85 350 435 545 735 // 1100 1210 1"1/4 1"1/4
TECHNICAL
SUPPORT
500 501 750 1800 1950 85 375 460 570 760 // 1329 1485 1"1/4 1"1/4
800 792 900 2135 2317 85 405 490 600 870 // 1610 1765 1"1/4 1"1/4
1000 1041 1000 2221 2436 105 458 543 653 993 // 1664 1818 1"1/2 1"1/2
1500 1443 1100 2415 2654 109 440 525 635 1075 // 1895 2050 1"1/2 2"
2000 1975 1300 2492 2811 91 467 542 652 842 1952 1877 2057 2" 2"
63
GAMMA BOLLY®
DHW
production
Number of heat
exchangers / / /
Energy source
Energy efficiency
B-C B-C A B-C
class
- Polyurethane hard
- Polyurethane hard - Polyurethane hard - Polyurethane hard
foam
Insulation - Dismountable polyester
foam foam foam
fleece
Available range 150 ÷ 1500 150 ÷ 500 200 ÷ 500 200 ÷ 500
64
EXTRA- BOLLY®
CALORIFIERS
ErP
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
Bolly® PDC Bolly® Murale Interka Interka Solare EVO
CYLINDERS - PUFFER
MULTIFUEL ENERGY
-Fixed spiral heat exchanger
Fixed spiral Double walled Double walled
- Heat exchanger module
heat exchanger heat exchanger heat exchanger
patented for heat pump
/ /
HYDRONIC
INERTIAL
TANKS
B-C C C B-C
WATER PRESSURE
- Polyurethane hard foam - Polyurethane hard foam - Polyurethane hard foam - Polyurethane hard foam
TANKS
65
BOLLY® 1 ST
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
POLYWARM®
S T O C K
grey
AVAILABILITY
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® 1 ST WB SURFACE CLASS
HARD FOAM
ErP
HARD FOAM INSULATION
www.cordivari.com/erp
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Electrical immersion flange plate Titanium electronic anode
ART. NR. FOR MODELS
5005000310002 WC See Accessories section See Accessories section
5005000310003 WB
66
BOLLY® 1 ST
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
1000 ÷ 1500 8 bar indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
Df 1 Drain 1"1/4 Gas F (3/4"su 800 e 1000.) (1" su 1500)
2 Domestic cold water circuit inlet
(11)
3 Primary circuit outlet
CALORIFIERS FOR
HEAT PUMP
4 Connection for instrumentation 1/2" Gas F
5 Blind flange for inspection
H12 (10) 6 Primary circuit inlet
7 Connection for magnesium anode 1"1/4 Gas F
H11(9)
8 Connection for electrical immersion
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
9 Recirculation
H8 (8)
H6(6) H7 (7) 10 Connection for instrumentation 1/2" Gas F
11 Domestic hot water outlet
H
HYDRONIC
H4
H3(3) (4) (5)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H2(2)
H1 (1) H1 (1)
0 0
(2)
INERTIAL
TANKS
(1)
(3) (6) (9) (5) (7) Models 1500 have two gripps on the
WATER PRESSURE
(12) bottom which allow the use of forklift
when handling and drain pipe already
TANKS
H1 (1) fitted.
(4) (8)(10) 0
Df De De
Volume Weight H A H1 H2 H3 H4
Model (vers. WC) (vers. WC) (vers. WB)
COMPRESSED AIR
1500 1443 389 950 1150 1100 2440 2654 109 450 425 575
ACCESORIES
H6 H7 H8 H11 H12 5 2 3 6 8 9 11
Model
[mm] Connections Gas F
150 888 956 1011 1065 1185 Ø 120 3/4" 1”1/4 1”1/4 1”1/2 3/4" 1”1/4
200 811 855 915 1089 1195 Ø 120 3/4" 1”1/4 1”1/4 1”1/2 3/4" 1”1/4
300 832 871 931 1101 1221 Ø 120 1" 1”1/4 1”1/4 1”1/2 1" 1”1/4
TECHNICAL
SUPPORT
400 988 1033 1091 1286 1486 Ø 120 1" 1”1/4 1”1/4 1”1/2 1" 1”1/4
500 1036 1076 1144 1331 1476 Ø 120 1" 1”1/4 1”1/4 1”1/2 1" 1”1/4
800 1181 1243 1308 1598 1788 Ø 160 1" 1”1/4 1”1/4 2” 1" 1”1/4
1000 1279 1309 1364 1584 1819 Ø 160 1"1/4 1”1/4 1”1/4 2” 1" 1"1/2
1500 1403 1450 1515 1825 2065 Ø 300 1"1/2 1”1/4 1”1/4 2” 1" 2"
67
BOLLY® 1 ST- HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C
and output 45°C;
4) Sanitary water according to UNI CTI 8065.
[mm.c.a.] O]
300
500 1,8
2
[mbar]
[mbar]
[mm.H
200 2000
800 2,7
200
1000 3,5 150 1500
150
1500 3,8 100 1000
50 500
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Portata [m3/h]
Flow Rate [m3/h]
Flow Rate
Portata [lt/min]
[lt/min]
0 20 40 60 80 100 120 140
500
5000
450
400
4000
1500
350 1000
[mm.c.a.] O]
300 3000
2
800
[mbar]
[mm.H
[mbar]
250
200 2000
150
100 1000
50
0 0
0 1 2 3 4 5 6 7 8 9
Portata [m3/h] 3
Flow Rate [m /h]
68
EXTRA- BOLLY®
BOLLY® 1 ST- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
STAINLESS STEEL
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
CALORIFIERS
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
195 251 258 272 298 407 440 507 2 218,85 21,46
193 247 253 266 287 388 418 479 1 60,62 5,95
253 325 335 354 392 536 581 675 2,5 441,12 43,26
CALORIFIERS FOR
HEAT PUMP
250 321 329 346 378 512 553 635 1,25 122,19 11,98
388 499 513 542 597 814 882 1021 3 927,45 90,95
384 492 504 529 578 780 839 960 1,5 256,91 25,19
550 706 723 759 814 1101 1186 1359 3,5 1480,67 145,20
546 697 712 744 791 1058 1133 1284 1,75 410,16 40,22
651 834 855 897 965 1304 1404 1607 3,5 1850,84 181,50
CYLINDERS - PUFFER
645 822 840 877 935 1249 1336 1510 1,75 512,70 50,28
MULTIFUEL ENERGY
1026 1314 1345 1410 1499 2023 2174 2483 6 1538,50 150,87
1017 1297 1325 1381 1455 1944 2076 2344 3 426,18 41,79
1345 1720 1759 1840 1952 2625 2815 3202 6 1994,35 195,58
1332 1696 1730 1799 1891 2512 2675 3004 3 552,45 54,18
1870 2378 2419 2504 2509 3330 3530 3936 6 2108,31 206,75
1856 2352 2388 2459 2443 3209 3378 3722 3 584,02 57,27
HYDRONIC
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
INERTIAL
TANKS
100
120
90
80 3,5 m 2 100
WATER PRESSURE
70
80
TANKS
60
Output [kW]
Output [[kW]
]
50
60 3,8 m 2
40
1,5 m 2
2,7 m 2
COMPRESSED AIR
40
30
RECEIVERS
1,2 m 2 1,8 m 2
20
0,8 m 2
20
10
0,6 m 2
0 0
55 60 65 70 75 80 55 60 65 70 75 80
AND SPARE PARTS
69
BOLLY® 2 ST
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
POLYWARM®
S T O C K
grey
AVAILABILITY
ENERGY
BOLLY® 2 ST WB HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM INSULATION
www.cordivari.com/erp
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
BOLLY® 2 ST WC HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE Upper Lower ErP
Model insulation
Art. Nr. [m ]
2
Accessories on request
“Easy Control” Electronic Display Electrical immersion flange plate Titanium electronic anode
ART. NR. FOR MODELS
5005000310002 WC See Accessories section See Accessories section
5005000310003 WB
70
BOLLY® 2 ST
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
1000 ÷ 1500 8 bar indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
Df
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
(15)
CALORIFIERS FOR
H12 (12) H13 (13)
HEAT PUMP
4 Connection for instrumentation 1/2" Gas F
H11 (11) 5 Blind flange for inspection
H10 (10) 6 Lower heat exchanger inlet
H9 (9) H8 (8) 7 Connection for magnesium anode 1"1/4 Gas F
H6 (6) H7 (7) 8 Connection for electrical immersion
9 Upper heat exchanger outlet
CYLINDERS - PUFFER
MULTIFUEL ENERGY
10 Connection for instrumentation 1/2” Gas F
11 Recirculation
12 Upper heat exchanger inlet
13 Connection for instrumentation 1/2” Gas F
15 Domestic hot water outlet
H3 (3) H4 (4) (5)
Connection for 2nd anode 1”1/4 Gas F
16
(only for models > 500)
H2 (2)
HYDRONIC
H1 (1)
0
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
(3) (6) (9) (1)
(11) (12) (5) (7) (16)
(14)
WATER PRESSURE
(13) H1 (1)
TANKS
0
Df De De
Volume Weight H A H1 H2 H3 H4 H6 H7
Model (vers. WC) (vers. WC) (vers. WB)
COMPRESSED AIR
150 148 54 // // 500 1414 1500 70 210 275 315 759 815
200 189 65 // // 550 1434 1536 70 220 285 325 811 855
300 291 83 // // 650 1486 1622 70 246 311 381 832 871
400 422 112 // // 700 1766 1900 70 261 326 396 988 1033
500 498 134 // // 750 1786 1937 70 271 346 411 1036 1076
800 789 232 750 950 900 2163 2343 101 493 428 483 1181 1243
1000 1038 272 850 1050 1000 2217 2432 89 524 439 499 1279 1309
AND SPARE PARTS
1500 1443 351 950 1150 1100 2440 2654 109 450 425 575 1403 1450
ACCESORIES
3-6
H8 H9 H10 H11 H12 H13 H14 5 1 2 8 11 15
Model 9-12
[mm] Connections Gas F
150 885 945 1035 1065 1185 1185 // Ø 120 1”1/4 3/4" 1”1/4 1” 3/4" 1”1/4
200 915 960 1105 1089 1195 1195 // Ø 120 1”1/4 3/4" 1”1/4 1” 3/4" 1”1/4
300 931 981 1076 1101 1221 1221 // Ø 120 1”1/4 1" 1”1/4 1” 1" 1”1/4
TECHNICAL
SUPPORT
400 1091 1143 1286 1286 1486 1486 // Ø 120 1”1/4 1" 1”1/4 1” 1" 1”1/4
500 1144 1186 1296 1331 1476 1476 // Ø 120 1”1/4 1" 1”1/4 1” 1" 1”1/4
800 1308 1362 1579 1598 1770 1788 1808 Ø 160 3/4” 1" 1”1/4 2” 1" 1”1/4
1000 1364 1399 1609 1584 1819 1819 1839 Ø 160 3/4” 1"1/4 1”1/4 2” 1" 1"1/2
1500 1515 1550 2045 1825 2065 1735 2065 Ø 300 1” 1"1/2 1”1/4 2” 1" 2"
71
BOLLY® 2 ST- HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
72
EXTRA- BOLLY®
BOLLY® 2 ST- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
CALORIFIERS
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
73 96 101 111 142 201 224 272 2 145,90 14,31
72 94 98 107 135 189 210 253 1 40,41 3,96
CALORIFIERS FOR
92 121 127 139 179 254 283 343 2,5 275,70 27,04
HEAT PUMP
90 118 124 135 172 241 267 323 1,25 76,37 7,49
141 185 194 211 265 373 413 498 3 541,01 53,06
139 181 189 205 255 355 393 469 1,5 149,87 14,70
211 276 288 313 388 544 603 723 3,5 1028,24 100,84
208 271 282 304 374 519 572 679 1,75 284,83 27,93
229 299 311 336 406 567 625 745 3,5 1028,24 100,84
CYLINDERS - PUFFER
MULTIFUEL ENERGY
227 294 305 327 392 542 595 702 1,75 284,83 27,93
401 521 541 581 684 950 1044 1236 6 911,70 89,41
397 513 531 567 662 911 995 1168 3 252,55 24,77
508 657 678 723 825 1137 1241 1456 6 1025,66 100,58
502 647 666 706 799 1091 1184 1376 3 284,12 27,86
691 891 919 974 1094 1499 1630 1897 6 1310,57 128,52
684 878 902 951 1059 1435 1551 1786 3 363,04 35,60
HYDRONIC
INERTIAL
TANKS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
WATER PRESSURE
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
TANKS
195 251 258 272 298 407 440 507 2 218,85 21,46
193 247 253 266 287 388 418 479 1 60,62 5,95
253 325 335 354 392 536 581 675 2,5 441,12 43,26
250 321 329 346 378 512 553 635 1,25 122,19 11,98
388 499 513 542 597 814 882 1021 3 927,45 90,95
384 492 504 529 578 780 839 960 1,5 256,91 25,19
COMPRESSED AIR
550 706 723 759 814 1101 1186 1359 3,5 1480,67 145,20
RECEIVERS
546 697 712 744 791 1058 1133 1284 1,75 410,16 40,22
651 834 855 897 965 1304 1404 1607 3,5 1850,84 181,50
645 822 840 877 935 1249 1336 1510 1,75 512,70 50,28
1026 1314 1345 1410 1499 2023 2174 2483 6 1538,50 150,87
1017 1297 1325 1381 1455 1944 2076 2344 3 426,18 41,79
1345 1720 1759 1840 1952 2625 2815 3202 6 1994,35 195,58
AND SPARE PARTS
1332 1696 1730 1799 1891 2512 2675 3004 3 552,45 54,18
ACCESORIES
1870 2378 2419 2504 2509 3330 3530 3936 6 2108,31 206,75
1856 2352 2388 2459 2443 3209 3378 3722 3 584,02 57,27
TECHNICAL
SUPPORT
73
BOLLY® 2 ST - PRESSURE LOSS
PRESSURE LOSS - UPPER FIXED HEAT EXCHANGER
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80
Heat exchanger surface [m2] 200
2000
500
150 0,4 180
400
300
400 1
120
500 1
[mm H2O]
[mbar]
100 200 1000
800 1,6
80
1000 1,8 150
60
1500 1,9 500
40
20
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
250
2500
1500
200 2000
1000
[mm H2O]
[mbar]
800
150 1500
100 1000
50 500
0 0
0 1 2 3 4 5 6 7 8 9
[mm H2O]
[mbar]
300
500 1,8 200 2000
50 500
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
450
400
4000
1500
350 1000
300 3000
[mm H2O]
800
[mbar]
250
200 2000
150
100 1000
50
0 0
0 1 2 3 4 5 6 7 8 9
74
EXTRA- BOLLY®
BOLLY® 2 ST - UPPER HEAT EXCHANGER OUTPUT CHART
CALORIFIERS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
BOLLYTERM®
CALORIFIERS
30
25
STAINLESS STEEL
1 m2
CALORIFIERS
20
0,75 m 2
Output [kW]
CALORIFIERS FOR
15
HEAT PUMP
0,5 m 2
10
CYLINDERS - PUFFER
MULTIFUEL ENERGY
0,4 m 2
0
55 60 65 70 75 80
Primary circuit temperature [°C]
HYDRONIC
Heat exchanger surface 0,4 m2 0,5 m2 0,75 m2 1 m2
MAX MIN MAX MIN MAX MIN MAX MIN
Flow rate [m3/h]
2 1 2,5 1,25 3 1,5 3,5 1,75
70
INERTIAL
TANKS
60
WATER PRESSURE
50
Output [kW]
TANKS
1,9 m 2
40
1,8 m 2
COMPRESSED AIR
RECEIVERS
30
1,6 m 2
20
AND SPARE PARTS
ACCESORIES
10
55 60 65 70 75 80
Primary circuit temperature [°C]
6 3 6 3 6 3
SUPPORT
75
BOLLY® 1 AP - HIGH PERFORMANCES
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
APPLICATION DRAIN
Production and storage of domestic hot water. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm®
HEAT EXCHANGER WARRANTY
1 Polywarm® coated fixed heat exchanger 5 years - See general sales conditions and warranty
INSULATION ACCESSORIES AND SPARE PARTS : See Accessories section for
High thermal insulation with ecological polyurethane hard foam. the entire list.
Grey PVC external lining
CATHODE PROTECTION
Magnesium anode.
POLYWARM®
S T O C K
grey
AVAILABILITY
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® 1 AP WB
HARD FOAM INSULATION
SURFACE CLASS
HARD FOAM
Model insulation [m2] ErP
Art. Nr.
150 3105162320501 1,1 B
200 3105162320502 1,5 B
www.cordivari.com/erp 300 3105162320503 1,8 C
400 3105162320504 2 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool
500 3105162320505 2,6 C
Accessories on request
“Easy Control” Electronic Display Electrical immersion flange plate Titanium electronic anode
ART. NR. FOR MODELS
See Accessories section Art. Nr. Model
5005000310003 WB
5200000000008 200, 300
5200000000009 500
76
BOLLY® 1 AP - HIGH PERFORMANCES
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
(12) CERTIFIED LABORATORIES
DATA RESULTS
H10 (11)
CALORIFIERS FOR
H9 (10)
HEAT PUMP
H8 (9) 1 Drain 1"1/4 Gas F
H6 (7) H7 (8)
2 Domestic cold water circuit inlet
H5 (6) 3 Heat exchanger outlet 1” 1/4 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
4 Connection for instrumentation 1/2" Gas F
HYDRONIC
0 9 Connection for electrical immersion 1”1/2 Gas F
(2)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
10 Recirculation
INERTIAL
(1)
TANKS
(3) (7) (10) (5) (8)
(12)
WATER PRESSURE
Volume Weight De H A H1 H2 H3 TANKS
Model
[litres] [Kg] [mm]
COMPRESSED AIR
H4 H5 H6 H7 H8 H9 H10 2-10
Model
[mm] Connections Gas F
150 315 725 888 956 1011 1065 1185 3/4"
200 325 735 1041 1155 1090 915 1195 3/4"
300 381 671 1020 1136 1071 1146 1221 1"
TECHNICAL
SUPPORT
77
BOLLY® 1 AP- HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
400 4000
400
350
300
300 3000
[mm H2O]
200
[mbar]
250
150
100 1000
50
0 0
0 1 2 3 4 5 6
78
EXTRA- BOLLY®
BOLLY® 1 AP- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
217 283 295 320 403 561 620 740 2 401,22 39,35
CALORIFIERS FOR
212 275 285 306 381 522 572 672 1 111,14 10,90
HEAT PUMP
284 371 387 421 540 752 832 996 2,5 827,10 81,11
278 360 374 403 511 701 768 906 1,25 229,11 22,47
414 538 558 599 725 1001 1097 1295 3 1391,18 136,43
407 525 542 577 692 941 1023 1190 1,5 385,37 37,79
573 738 761 807 920 1257 1366 1589 3,5 2056,48 201,67
565 725 744 784 886 1194 1288 1477 1,75 569,66 55,86
CYLINDERS - PUFFER
MULTIFUEL ENERGY
686 884 913 971 1132 1546 1683 1960 3,5 262,17 2673,43
676 866 889 938 1084 1456 1571 1802 1,75 72,62 740,56
HYDRONIC
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
70
INERTIAL
TANKS
60
WATER PRESSURE
TANKS
50
Output [kW]
2,6 m 2
40
COMPRESSED AIR
RECEIVERS
2 m2
30 1,8 m 2
1,5 m 2
AND SPARE PARTS
ACCESORIES
20
1,1 m 2
10
55 60 65 70 75 80
TECHNICAL
SUPPORT
79
BOLLY® 2 AP- HIGH PERFORMANCES
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
APPLICATION DRAIN
Production and storage of domestic hot water. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm®
HEAT EXCHANGER WARRANTY
2 Polywarm® coated fixed heat exchangers 5 years - See general sales conditions and warranty
INSULATION ACCESSORIES AND SPARE PARTS
High thermal insulation with ecological polyurethane hard foam. See Accessories section for the entire list.
Grey PVC external lining
CATHODE PROTECTION
Magnesium anode.
POLYWARM®
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
BOLLY® 2 AP WB HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM Upper Lower ErP
Model insulation
Art. Nr. [m ]
2
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
500 3135162320505 1,3 2 C
Accessories on request
“Easy Control” Electronic Display Electrical immersion flange plate Titanium electronic anode
ART. NR. FOR MODELS
See Accessories section Art. Nr. Model
5005000310003 WB
5200000000008 200, 300
5200000000009 500
80
BOLLY® 2 AP- HIGH PERFORMANCES
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
De DATA RESULTS
(16)
CALORIFIERS FOR
HEAT PUMP
1 Drain 1"1/4 Gas F
H12 (13)
(14) 2 Domestic cold water circuit inlet 1" Gas F
H11 (12) 3 Lower heat exchanger outlet 1"1/4 Gas F
A
H10 (11)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
4 Connection for instrumentation 1/2" Gas F
H9 (10) H8 (9)
H6 (7) H7 (8)
5 Blind flange for inspection Øi 120 mm
HYDRONIC
9 Connection for electrical immersion 1”1/2 Gas F
H4 (4) (5)
H3 (3)
10 Upper heat exchanger outlet 1"1/4 Gas F
H2 (2)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
14 Connection for instrumentation 1/2” Gas F
(1)
WATER PRESSURE
(3) (7) (10) (5) (8)
(12) (13) (16)
TANKS
(4) (6) (9) (11) (14)
COMPRESSED AIR
Volume Weight De H A H1 H2 H3
Model
RECEIVERS
500 411 896 1036 1076 1144 1186 1296 1331 1476
SUPPORT
81
BOLLY® 2 AP- HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
[mm H2O]
150 1500
[mbar]
100 1000
200
50 500
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Flow Rate [m /h]3
500 2
[mbar]
200 2000
150 1500
100 1000
50 500
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Flow Rate [m3/h]
82
EXTRA- BOLLY®
BOLLY® 2 AP- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
STAINLESS STEEL
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
CALORIFIERS
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
149 197 208 229 303 430 481 585 3 194,65 19,09
146 191 201 220 287 402 447 538 1,5 53,92 5,29
242 317 332 363 465 654 727 876 3,5 316,51 31,04
237 309 322 349 444 614 678 808 1,75 87,68 8,60
CALORIFIERS FOR
HEAT PUMP
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
CYLINDERS - PUFFER
MULTIFUEL ENERGY
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
397 512 528 561 640 877 954 1113 3 1082,03 106,11
392 503 517 545 616 833 901 1038 1,5 299,73 29,39
660 847 869 916 1007 1366 1475 1697 3,5 2056,48 201,67
652 834 853 893 973 1303 1396 1586 1,75 569,66 55,86
HYDRONIC
HEAT EXCHANGERS OUTPUT CHART BOLLY® 2 AP
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
INERTIAL
TANKS
35
55
WATER PRESSURE
30
50
TANKS
45
25
1,3 m2
40
Output [kW]
Output [kW]
20 2 m2
35
COMPRESSED AIR
0,9 m2
15
RECEIVERS
30
1,4 m 2
25
10
0,4 m2
20
15
AND SPARE PARTS
0
ACCESORIES
55 60 65 70 75 80 10
55 60 65 70 75 80
Heat exchanger surface 0,4 m2 0,9 m2 1,3 m2 Heat exchanger surface 1,4 m2 2 m2
MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN
Flow rate [m3/h] Flow rate [m /h]
3
2 1 3 1,5 3,5 1,75 3 1,5 3,5 1,75
TECHNICAL
SUPPORT
83
BOLLY® 1 CLASSE A
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
APPLICATION DRAIN
Production and storage of domestic hot water. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm®
HEAT EXCHANGER WARRANTY
1 Polywarm® coated fixed heat exchanger. 5 years - See general sales conditions and warranty
INSULATION ACCESSORIES AND SPARE PARTS :
High thermal insulation with ecological polyurethane hard foam. See Accessories section for the entire list.
Grey PVC external lining
CATHODE PROTECTION
Magnesium anode.
POLYWARM®
A
HARD FOAM INSULATION
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® 1 WB CLASSE A SURFACE CLASS
HARD FOAM
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Model insulation [m2] ErP
Art. Nr.
200 3104162330002 0,8 A
www.cordivari.com/erp 300 3104162330003 1,2 A
On line ErP label tool 500 3104162330005 1,8 A
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5032240000107 See Accessories section
5005000310003 WB
5 units box
84
BOLLY® 1 CLASSE A
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
STAINLESS STEEL
indicated by Ecodesign ErP Directive.
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
De
(11)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
1 Drain
H12 (10) 2 Domestic cold water circuit inlet
H11(9) 3 Primary circuit outlet 1” 1/4 F
A
HYDRONIC
5 Blind flange for inspection (Øi 70 mm)
6 Primary circuit inlet 1” 1/4 F
H
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H4 9 Recirculation
H3(3)
INERTIAL
(4) (5)
TANKS
11 Domestic hot water outlet 1” 1/4 F
H2(2)
H1 (1)
0
WATER PRESSURE
(2)
(1) TANKS
(3) (6) (9) (5) (7)
(12)
COMPRESSED AIR
RECEIVERS
(4) (8)(10)
AND SPARE PARTS
ACCESORIES
500 498 138 1000 1911 2157 70 271 346 411 1036 1076 1144 1331 1476 1” 1/4 1" 1"
85
BOLLY® 2 CLASSE A
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
APPLICATION DRAIN
Production and storage of domestic hot water. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm®
HEAT EXCHANGER WARRANTY
2 Polywarm® coated fixed heat exchangers. 5 years - See general sales conditions and warranty
INSULATION ACCESSORIES AND SPARE PARTS :
High thermal insulation with ecological polyurethane hard foam. See Accessories section for the entire list.
Grey PVC external lining
CATHODE PROTECTION
Magnesium anode.
POLYWARM®
A
HARD FOAM INSULATION
ENERGY
BOLLY® 2 WB CLASSE A HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
HARD FOAM Upper Lower ErP
Model insulation
Art. Nr. [m ]2
www.cordivari.com/erp
200 3134162330002 0,4 0,6 A
On line ErP label tool 300 3134162330003 0,5 0,8 A
500 3134162330005 0,7 1,2 A
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. FOR MODELS Art. Nr.
5032240000107 See Accessories section
5005000310002 WC
5 units box
86
BOLLY® 2 CLASSE A
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
STAINLESS STEEL
indicated by Ecodesign ErP Directive.
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
CALORIFIERS FOR
HEAT PUMP
(15)
1 Drain
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H12 (12) H13 (13)
H11 (11) 2 Domestic cold water circuit inlet
3 Primary circuit outlet 1” Gas F
H10 (10)
H9 (9) H8 (8) 4-10 -13 Connection for instrumentation 1/2” Gas F
H6 (6) H7 (7)
5 Blind flange for inspection (Øi 70 mm)
6 Primary circuit inlet 1” Gas F
HYDRONIC
7 Connection for magnesium anode 1”1/4 Gas F
8 Connection for electrical immersion 1”1/2 Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
H1 (1) 15 Domestic hot water outlet 1” 1/4 Gas F
0
(2)
WATER PRESSURE
TANKS
(3) (6) (9) (1)
(11) (12) (5) (7)
(14)
(13)
RECEIVERS
Volume
Weight De H A H1 H2 H3 H4 H6 H7 H8 H9 H10 H11 H12 H13 1 2 9
Model netto
AND SPARE PARTS
200 189 72 650 1484 1620 70 220 285 325 811 855 915 960 1105 1089 1195 1195 1”1/4 3/4" 3/4"
300 291 92 750 1536 1709 70 246 311 381 832 871 931 981 1076 1101 1221 1221 1”1/4 1" 1"
500 498 152 1000 1911 2157 70 271 346 411 1036 1076 1144 1186 1296 1331 1476 1476 1”1/4 1" 1"
TECHNICAL
SUPPORT
87
BOLLY® XL
POLYWARM® COATED CALORIFIERS WITH 1 FIXED HEAT EXCHANGER
APPLICATION DRAIN
Production and storage of domestic hot water. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm® treatment
HEAT EXCHANGER and connection for electrical immersion heater.
Polywarm® coated fixed heat exchanger. WARRANTY
INSULATION 5 years - See general sales conditions and warranty
High thermal insulation with ecological polyurethane hard foam. ACCESSORIES AND SPARE PARTS : See Accessories section for
Grey PVC external lining the entire list.
CATHODE PROTECTION
Magnesium anode.
POLYWARM®
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® XL WB SURFACE CLASS
HARD FOAM
Model insulation [m2] ErP
Art. Nr.
200 3105162320702 2 B
300 3105162320703 3,4 C
400 3105162320706 4,4 C
500 3105162320705 5,4 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. Art. Nr.
5032240000107 Art. Nr. Model
5005000310003
5 units box 5200000000008 200, 300,400
5200000000009 500
88
BOLLY® XL
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(10) (11)
CALORIFIERS FOR
HEAT PUMP
H11 (9) H10 (8)
H9 (7)
1 Drain 1"1/4 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2 Domestic cold water circuit inlet
HYDRONIC
H4 (4) (5) (6) 6 Connection for electrical immersion 1"1/2 Gas F
H3 (3)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H2 (2) 7 Recirculation
INERTIAL
TANKS
10 Connection for magnesium anode 1"1/4 Gas F
WATER PRESSURE
TANKS
(4) (8)
Volume De H A H1 H2
Model
COMPRESSED AIR
[litres] [mm]
RECEIVERS
89
BOLLY® XL - HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
[mm H2O]
90
EXTRA- BOLLY®
BOLLY® XL- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
STAINLESS STEEL
CALORIFIERS
T1/t2 T1/t2
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
303 399 420 462 634 888 989 1192 2,5 325,22 29,66
295 384 401 436 594 815 898 1066 1,25 83,78 8,22
476 626 659 726 1022 1424 1583 1904 3 726,71 71,27
460 596 622 674 942 1281 1406 1657 1,5 201,30 19,74
CALORIFIERS FOR
188 274 317 403 903 1314 1519 1933 3,5 1266,07 124,15
HEAT PUMP
649 777 871 938 1281 1440 1889 2210 1,75 350,94 34,41
793 1034 1084 1183 1647 2267 2504 2980 3,5 1539,43 150,97
766 985 1023 1098 1516 2031 2212 2574 1,75 426,43 41,82
CYLINDERS - PUFFER
MULTIFUEL ENERGY
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
HYDRONIC
140
120
INERTIAL
TANKS
100
WATER PRESSURE
Output [kW]
80
5,4 m2
TANKS
4,4 m2
60
COMPRESSED AIR
3,4 m2
RECEIVERS
40
2 m2
AND SPARE PARTS
20
ACCESORIES
0
55 60 65 70 75 80
Primary circuit temperature [°C]
TECHNICAL
SUPPORT
91
BOLLY® MURALE
HANGED POLYWARM® COATED CALORIFIER FOR D.H.W. PRODUCTION
WITH 1 FIXED HIGH EFFICIENCY HEAT EXCHANGER
APPLICATION CATHODE PROTECTION
Production and storage of domestic hot water. Magnesium anode.
MATERIAL DRAIN
Mild steel Polywarm® coated (Attestation ACS - SSICA - External confluence through drain connection.
DVGW - W270 - UBA - WRAS). WARRANTY
Complete with wall brackets 5 years - See general sales conditions and warranty
HEAT EXCHANGER ACCESSORIES AND SPARE PARTS
Mild steel Polywarm® coated heat exchanger. See Accessories section for the entire list.
INSULATION
Ecological hard polyurethane foam with high thermal
insulation. PVC external lining complete with top cover.
POLYWARM®
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® MURALE WB
HARD FOAM INSULATION
SURFACE CLASS
HARD FOAM
Model insulation [m2] ErP
Art. Nr.
80 3104160900021 0,44 C
100 3104160900022 0,44 C
S T O C K
AVAILABILITY 150 3104160900023 0,63 C
grey
200 3104160900024 0,84 C
300 3104160900025 1,22 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Output Ignition time Production of D.H.W.
Model
Thermic data are calculated with primary at 85°C and
production of DHW from 10 to 45°C with storage at 60°C
[kW] [min] [lt/h] [lt/10']
80 14 26 345 171
100 14 32 345 200
150 21 33 508 298
200 29 32 704 403
300 42 34 1027 599
Accessories on request
“Easy Control” Electronic Display Thermometer Magnesium anode
ART. NR. FOR MODELS Art. Nr. ART. NR. FOR MODELS
5032240000107 5200000041015 80÷150
5005000310003 WB
5 units box 5200000041010 200÷300
2 units box
92
BOLLY® MURALE
EXTRA- BOLLY®
CALORIFIERS
HANGED POLYWARM® COATED CALORIFIER FOR D.H.W. PRODUCTION
WITH 1 FIXED HIGH EFFICIENCY HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
10 bar 90 °C 12 bar 110 °C Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
D
(8) ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
H5 (5)
HEAT PUMP
IF L
H
L1 (2)
L3 (3)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H3 (3) H4 (4)
H2
H1 (2)
D (1) (8)
0 (1)
180
HYDRONIC
0 L4 (4) L5 (5) L7 (6-7)
E
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
L2 IF L6
(5) (6)
Centre-to-centre distance for installation on wall
(2) (3)
(1) (8)
INERTIAL
TANKS
(4) (7)
WATER PRESSURE
TANKS
VERTICAL WALL HANGED HORIZONTAL WALL HANGED
1 Connection 1"1/4 Gas F 1 Connection 1"1/4 Gas F
2 Domestic cold water circuit inlet 1"Gas F 2 Domestic cold water circuit inlet 1"Gas F
3 Primary circuit outlet 1”1/4 Gas F 3 Primary circuit outlet 1”1/4 Gas F
4 Connection for instrumentation 1/2" Gas F 4 Connection for instrumentation 1/2" Gas F
COMPRESSED AIR
5 Primary circuit inlet 1”1/4 Gas F 5 Primary circuit inlet 1”1/4 Gas F
RECEIVERS
6 Connection for instrumentation 1/2” Gas F 6 Connection for instrumentation 1/2” Gas F
7 Domestic hot water outlet 1”Gas F 7 Domestic hot water outlet 1”Gas F
8 Magnesium anode 1”1/4 Gas F 8 Magnesium anode 1”1/4 Gas F
AND SPARE PARTS
ACCESORIES
Volume Weight D H/L H1/L1 H2/L2 H3/L3 H4/L4 H5/L5 H6/L6 H7/L7 IF E
Model
[litres] [Kg] [mm]
80 84 25 456 800 195 235 290 315 510 600 605 365 250
100 103 29 456 954 205 222 300 315 655 732 750 510 250
TECHNICAL
SUPPORT
150 149 40 456 1330 205 335 300 315 1030 1005 1125 670 250
200 191 47 510 1350 215 320 310 325 1040 1035 1135 715 275
300 293 62 610 1400 240 345 335 350 1065 1060 1160 715 325
93
BOLLY® MURALE - HEAT EXCHANGERS TECHNICAL DATA
Data have been calculated on following basis:
1) Primary circuit at T1 and proper energy source;
2) Production of DHW in continue way from 10 °C at t2;
3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water according to UNI CTI 8065.
200 2000
200
150 1500
[mm H2O]
[mbar]
100 1000
50 500
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
200 2000
150 1500
[mm H2O]
150
[mbar]
100 80/100
1000
50 500
0 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
94
EXTRA- BOLLY®
BOLLY® MURALE- HEAT EXCHANGERS TECHNICAL DATA
CALORIFIERS
BOLLYTERM®
CALORIFIERS
DHW produced in the first 10 minutes in lt/10’ DHW produced in the first hour in lt/60’
input 10 °C output 45 °C, input 10 °C output 45 °C, Flow rate Exchanger pressure loss
storage at t2 and primary at T1 storage at t2 and primary at T1
STAINLESS STEEL
T1/t2 T1/t2
CALORIFIERS
[m3/h] [mm.H2O] [mbar]
55/50 65/60 70/60 80/60 55/50 65/60 70/60 80/60
110 143 149 159 183 254 280 330 2 175 17
109 141 146 155 175 242 265 310 1 51 5
133 172 177 188 205 283 308 359 2 175 17
132 170 174 184 198 271 293 339 1 51 5
191 246 253 267 289 394 427 494 2 229 22
CALORIFIERS FOR
189 243 248 261 279 382 406 465 1 67 7
HEAT PUMP
249 320 330 350 390 534 580 675 2,5 472 46
246 316 324 342 376 511 551 635 1,25 139 14
379 487 501 528 580 790 856 989 3 908 89
375 480 492 516 563 758 815 932 1,5 268 26
CYLINDERS - PUFFER
MULTIFUEL ENERGY
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
HYDRONIC
1,22 m
2
INERTIAL
TANKS
WATER PRESSURE
0,84 m
Output [kW]
TANKS
0,63 m 2
COMPRESSED AIR
RECEIVERS
0,44 m 2
AND SPARE PARTS
ACCESORIES
95
INTERKA
POLYWARM® COATED DOUBLE WALLED TANK IN TANK CALORIFIERS FOR D.H.W. PRODUCTION
APPLICATION INSULATION
Production and storage of domestic hot water. High thermal insulation with ecological polyurethane hard
MATERIAL foam.
Mild steel Polywarm® coated (Attestation ACS - SSICA - Grey PVC external lining
DVGW - W270 - UBA - WRAS). CATHODE PROTECTION
HEAT EXCHANGER Magnesium anode.
Double walled heat exchanger. WARRANTY
5 years - See general sales conditions and warranty
ACCESSORIES AND SPARE PARTS : See Accessories
section for the entire list.
POLYWARM®
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
HEAT EXCHANGER EFFICIENCY
INTERKA WB SURFACE CLASS
HARD FOAM
Model insulation [m2] ErP
Art. Nr.
80 3203160310001 0,36 C
100 3203160310002 0,54 C
www.cordivari.com/erp 150 3203160310003 0,82 C
On line ErP label tool 200 3203160310004 1,00 C
300 3203160310015 1,40 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Production of
Output Ignition time Weight
Model D.H.W.
[kW] [min] [lt/h] [lt/10’] [Kg]
80 8 27 190 112 24
100 11 24 263 144 30
150 15 26 372 212 41
200 20 25 508 285 49
300 24 31 606 401 65
Data have been calculated on following basis:
• primary water at 80°C
• DHW production from 10°C to 45°C.
Even if tanks are tested to resist from max temp. 60 °C to 90 °C the local
Vertical or horizontal wall hanged legislation has always to be observed during the use.
Accessories on request
Electric immersion with thermostat Thermometer Magnesium anode
Con- Art. Nr. ART. NR. Model
Art. Nr. Output
nection 5032240000107 5200000041015 80÷150
5240000000042 1,5 kW 1” 1/4 5 units box 5200000041010 200÷300
2 units box
96
INTERKA
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOUBLE WALLED TANK IN TANK CALORIFIERS FOR D.H.W. PRODUCTION
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
(1) (2) (3) (4) (5)
0
CYLINDERS - PUFFER
MULTIFUEL ENERGY
7 Connection for magnesium anode 1”1/4 Gas F
(2) (3) De
(6)
HYDRONIC
(6) (1) (2)
180
(1)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
(7)
(3)
180
INERTIAL
(4) (5) L
TANKS
(7)(6)
(4) (5) (2) (3)
(4)
WATER PRESSURE
(5)
TANKS
(1)
(7)
COMPRESSED AIR
RECEIVERS
NOTE:
THIS INSTALLATION MAY REDUCE THE
D.H.W. STORAGE VOLUME.
AND SPARE PARTS
ACCESORIES
Volume De L L1 L2 L3 L4 2-3-4-5
Model
[lt] [mm] Connections Gas F
80 82 456 770 165 260 510 605 1"
100 100 456 920 165 260 660 755 1"
TECHNICAL
SUPPORT
97
INTERKA SOLARE EVO
POLYWARM® COATED DOUBLE WALLED TANK IN TANK CALORIFIERS FOR D.H.W. PRODUCTION
SUITABLE FOR SOLAR THERMAL SYSTEMS
APPLICATION INSULATION
Production and storage of domestic hot water. High thermal insulation with ecological polyurethane hard
MATERIAL foam.
Mild steel Polywarm® coated (Attestation ACS - SSICA - Pre-painted sheet external lining and ABS cupels.
DVGW - W270 - UBA - WRAS). CATHODE PROTECTION
HEAT EXCHANGER Magnesium anode.
Double walled heat exchanger. WARRANTY
5 years - See general sales conditions and warranty
ACCESSORIES AND SPARE PARTS : See Accessories
section for the entire list.
POLYWARM®
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
INTERKA SOLARE EVO WB DOUBLE WALLED HEAT EXCHANGER EFFICIENCY
CLASS
HARD FOAM
Surface Volume
Model insulation ErP
Art. Nr. [m ] 2
[lt]
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
150 3068160980112 0,80 8,0 B
200 3068160980113 1,20 12,0 B
300 3068160980124 2,05 21,0 C
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Electrical immersion with cover Thermometer Magnesium anode
Con- Art. Nr. ART. NR. Model
Art. Nr. Output
nection 5032240000107 5200000041008 150
5240000000062 1,5 kW 1” 1/4 5 units box 5200000041009 200,300
See Cordivari integrated thermal solar systems catalogue 2 units box
98
INTERKA SOLARE EVO
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DOUBLE WALLED TANK IN TANK CALORIFIERS FOR D.H.W. PRODUCTION
SUITABLE FOR SOLAR THERMAL SYSTEMS
BOLLYTERM®
that test procedures and
CALORIFIERS
6 bar 90 °C 2,5 bar 99 °C Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
(5) 1 Sanitary water inlet 3/4" Gas F
(6) 2 Solar collector connection 3/4" Gas F
3 Purge volume 1/2" Gas F
(7) (8)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
De
HYDRONIC
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
WATER PRESSURE
TANKS
COMPRESSED AIR
RECEIVERS
Volume De L I L1 L2
Model
[lt] [mm]
150 143 550 1040 430 298 728
200 183 550 1300 640 323 963
TECHNICAL
SUPPORT
99
100
101
BOLLYTERM ®
CALORIFIERS
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
BOLLYTERM® RANGE
DHW
production
Bollyterm® HP Bollyterm® HP 1
Number of heat
exchangers
Energy source
Energy efficiency
A+ A+
class
102
A+
300
installations
floor standing
Bollyterm® HP 2
103
ErP
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
BOLLYTERM® HP
POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP
POLYWARM®
MCE - EXPOCOMFORT
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
BOLLYTERM® HP EFFICIENCY
CLASS
HARD FOAM
Model insulation ErP
Art. Nr.
200 3180162330102 A+
300 3180162330103 A+
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
ErP Energy Ignition time Maximum
Net volume Room Electrical absorption
efficiency (Air temperature 20 °C -
heated from heat temperature integration
Model C.O.P. class Water temperature from 15 Heat
pump output power Total
(Reg EU °C to 55 °C) pump
812/2013)
[litres] [°C] [min] [W] [W]
www.cordivari.com/erp 200 176 2,98(*) A+ 236’
-5/+43 1500 805 2305
On line ErP label tool 300 264 2,91(*) A+ 353’
(*) Data obtained under the following conditions (T air 20 °C - T water from 15 °C to 55 °C)
Accessories on request
Thermometer Titanium electronic anode
Art. Nr.
5032240000107 Art. Nr. Model
5 units box 5200000000008 200, 300
104
BOLLYTERM® HP
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP
STORAGE T Ü V R h e i n l a n d Energie
Pmax Tmax
und Umwelt GmbH states 2
that test procedures and
10 bar 90 °C Cordivari LAB are certified conforming
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
A+
1
A POLITECNICO DI MILANO
STAINLESS STEEL
B Dipartimento di Energia
CALORIFIERS
C RELAB- Renewable Heating and Cooling LAB
D
E
F External to the storage condensator coil
1 avoiding any contact coolant - D.H.W.
CALORIFIERS FOR
Electronic Central Unit (included):
2
HEAT PUMP
ASK ALWAYS FOR - set point hot water
CERTIFIED LABORATORIES
DATA RESULTS - self check
- anti-legionellosis treatement
- operating programs
- “BOOST” mode
CYLINDERS - PUFFER
MULTIFUEL ENERGY
De
INT
HYDRONIC
1 Drain 1" 1/4 GAS F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
H6 (8)
6 Anode 1"1/4 GAS F
H5 (7)
7 Recirculation 1" GAS F
8 Domestic cold water circuit outlet 1" GAS F
H
WATER PRESSURE
ANODEN TESTER
Kontrolltaste drücken
TANKS
A
Ø180
H3 (3)(4)
RECEIVERS
H2 (2)
Volume De INT H A H1 H2 H3 H4 H5 H6
Model
TECHNICAL
SUPPORT
[litres] [mm]
200 205 640 340 1585 1684 71 240 350 800 815 925
300 293 640 340 1960 2040 71 240 350 860 1190 1300
105
BOLLYTERM® HP 1
POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP AND 1 FIXED HEAT EXCHANGER
POLYWARM®
MCE - EXPOCOMFORT
HARD FOAM INSULATION
ENERGY
HEAT EXCHAN- EFFICIENCY
BOLLYTERM® HP 1 GER SURFACE CLASS
HARD FOAM
Model insulation [m2] ErP
S T O C K Art. Nr.
grey
AVAILABILITY 200 3181162330102 0,8 A+
300 3181162330103 1,2 A+
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
ErP Energy Ignition time Maximum
Net volume Room Electrical absorption
efficiency (Air temperature 20 °C -
heated from heat temperature integration
Model C.O.P. class Water temperature from 15 Heat
pump output power Total
(Reg EU °C to 55 °C) pump
812/2013)
[litres] [°C] [min] [W] [W]
www.cordivari.com/erp 200 176 2,98(*) A+ 236’
-5/+43 1500 805 2305
On line ErP label tool 300 264 2,91(*) A+ 353’
(*) Data obtained under the following conditions (T air 20 °C - T water from 15 °C to 55 °C)
Accessories on request
Thermometer Titanium electronic anode
Art. Nr.
5032240000107 Art. Nr. Model
5 units box 5200000000008 200, 300
106
BOLLYTERM® HP 1
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP AND 1 FIXED HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
A+
A POLITECNICO DI MILANO
STAINLESS STEEL
B Dipartimento di Energia
CALORIFIERS
C RELAB- Renewable Heating and Cooling LAB
D
E
F
1
CALORIFIERS FOR
HEAT PUMP
ASK ALWAYS FOR
CERTIFIED LABORATORIES External to the storage condensator coil
DATA RESULTS 1 avoiding any contact coolant - D.H.W.
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Electronic Central Unit (included):
2
- set point hot water
- self check
- anti-legionellosis treatement
- operating programs
- “BOOST” mode
De
INT
HYDRONIC
1 Drain 1" 1/4 GAS F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
5 Connection for instrumentation 1/2" GAS F
TANKS
6 Anode 1"1/4 GAS F
H6 (8) 7 Recirculation 1" GAS F
H5 (7) 8 Domestic cold water circuit outlet 1" GAS F
9 Heat exchanger outlet 1”1/4 Gas F
WATER PRESSURE
10 Heat exchanger inlet ”1/4 Gas F
H
TANKS
ANODEN TESTER
Kontrolltaste drücken
Ø180
COMPRESSED AIR
RECEIVERS
H3 (3)(4) H7 (9)
(2) (7) (8)
H2 (2)
H1 (1)
AND SPARE PARTS
(3) (5)
ACCESORIES
(6)
(4)
Volume De INT H A H1 H2 H3 H4 H5 H6 H7 H8
Model
TECHNICAL
SUPPORT
[lt] [mm]
200 205 640 340 1585 1684 71 240 350 800 815 925 345 765
300 293 640 340 1960 2040 71 240 350 860 1190 1300 351 755
107
BOLLYTERM® HP 2
POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP
AND 2 FIXED HEAT EXCHANGERS
APPLICATION CATHODE PROTECTION
Production and storage of domestic hot water. Magnesium anode.
MATERIAL DRAIN
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 External confluence through drain connection.
- UBA - WRAS) GASKET- FLANGE PLATE
HEAT PUMP Silicone gaskets suitable for alimentary use; Mild steel Polywarm®
The water inside the tank is warmed up by an integrated insulated coated flange plate with electrical immersion resistance .
compressor heat pump equipped with external condensing coil. A WARRANTY
1500 Watt electric resistance with “BOOST” option is already installed. 5 years (tank)
Electronic gear case with graphic display allows controlling and See general sales conditions and warranty for electrical parts.
planning. ACCESSORIES AND SPARE PARTS
HEAT EXCHANGER See Accessories section for the entire list.
2 Polywarm® coated fixed heat exchangers
INSULATION
High thermal insulation with ecological polyurethane hard foam.
PVC external lining complete with ABS top and flange cover.
POLYWARM®
MCE - EXPOCOMFORT
HARD FOAM INSULATION
ENERGY
BOLLYTERM® HP 2 HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
ErP Energy Ignition time Maximum
Net volume Room Electrical absorption
efficiency (Air temperature 20 °C -
heated from heat temperature integration
Model C.O.P. class Water temperature from 15 Heat
pump output power Total
(Reg EU °C to 55 °C) pump
812/2013)
[litres] [°C] [min] [W] [W]
www.cordivari.com/erp 300 264 -5/+43 2,91(*) A+ 353’ 1500 805 2305
On line ErP label tool (*) Data obtained under the following conditions (T air 20 °C - T water from 15 °C to 55 °C)
Accessories on request
Thermometer Titanium electronic anode
Art. Nr.
5032240000107 Art. Nr. Model
5 units box 5200000000008 300
108
BOLLYTERM® HP 2
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH INTEGRATED HEAT PUMP
AND 2 FIXED HEAT EXCHANGERS
STORAGE HEAT EXCHANGER
T Ü V R h e i n l a n d Energie
Pmax Tmax Pmax Tmax und Umwelt GmbH states
10 bar 90 °C 12 bar 110 °C
BOLLYTERM®
that test procedures and
CALORIFIERS
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
2
A+
STAINLESS STEEL
A
CALORIFIERS
B POLITECNICO DI MILANO
C Dipartimento di Energia
D RELAB- Renewable Heating and Cooling LAB
E
F 1
CALORIFIERS FOR
HEAT PUMP
External to the storage condensator coil
ASK ALWAYS FOR 1 avoiding any contact coolant - D.H.W.
CERTIFIED LABORATORIES
DATA RESULTS
De
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Electronic Central Unit (included):
2
INT - set point hot water
- self check
- anti-legionellosis treatement
- operating programs
- “BOOST” mode
HYDRONIC
2 Domestic cold water circuit inlet 1" GAS F
3 Connection for instrumentation 1/2" GAS F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H6 (8)
Flange for inspection Ø 75 / Electrical immer-
H11 (13) H10 (12) 4
H5 (7) sion
5 Connection for instrumentation 1/2" GAS F
6 Anode 1"1/4 GAS F
INERTIAL
TANKS
H
WATER PRESSURE
11 Upper heat exchanger outlet 1” 1/4 Gas F
12 Upper heat exchanger inlet 1" 1/4 Gas F
TANKS
H3 (3)(4) H7 (9) 13 Connection for instrumentation 1/2" Gas F
H2 (2)
H1 (1)
0
COMPRESSED AIR
RECEIVERS
Ø180
AND SPARE PARTS
109
110
316L
STEEL
111
STAINLESS
CALORIFIERS
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
EXTRA 1 INOX
316 L STAINLESS STEEL CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
APPLICATION
Production and storage of domestic hot water. CATHODE PROTECTION
MATERIAL Magnesium anode. - Models > 1500 n° 2 magnesium anodes.
Stainless Steel 316 L suitable for domestic hot water according to DRAIN
D.M. n. 174 dated 06.04.04. External confluence through drain connection.
HEAT EXCHANGER GASKET- FLANGE PLATE
316L Stainless Steel Antilegionella® heat exchanger, with tubes bent Silicone gaskets suitable for alimentary use; Mild steel exchanger
to the bottom head with anticorrosion treatment.
INSULATION WARRANTY
- HARD: High thermal insulation with ecological polyurethane hard foam. 5 years - See general sales conditions and warranty
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, ACCESSORIES AND SPARE PARTS
with high thermal insulation. Fire resistance class B-s2d0 according See Accessories section for the entire list.
to EN 13501.
Grey PVC external lining complete with top and flange cover
ENERGY
EXTRA 1 XXB HEAT EXCHANGER EFFICIENCY
HARD FOAM INSULATION
CLASS
SURFACE
HARD FOAM INOX 316L
Model insulation ErP
Art. Nr. [m2]
200 3072052300422 0,5 C
300 3072052300423 0,75 C
500 3072052300424 1 C
www.cordivari.com/erp ENERGY
EXTRA 1 XXC HEAT EXCHANGER EFFICIENCY
CLASS
On line ErP label tool SURFACE
DISMOUNTABLE SOFT FLEECE INOX 316L
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display
ART. NR. FOR MODELS
5005000310002 XXC
5005000310003 XXB
112
EXTRA 1 INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
Df
(14)
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
H17 (11) CERTIFIED LABORATORIES
(12) (13) DATA RESULTS
H16 (10)
H15 (9)
CALORIFIERS FOR
A
HEAT PUMP
Drain 3/4” Gas F for models da 200 a 1000;
H
1
1” Gas F for models > 1000
H7 (8)
H6 (7) 2 Domestic cold water circuit inlet
H4 (5) (16) Alternative domestic cold water circuit inlet or connection
3
H5 (6) for more boilers
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H2 (2) (3) 4 Primary circuit outlet
H3 (4)
5 Heat exchanger flange
6 Primary circuit inlet
H1(1) 7 Connection for instrumentation 1/2" Gas F
0 8 Connection for magnesium anode 1"1/4 Gas F
Connection for 2nd anode 1"1/4 Gas F (only for models >
9
1500)
HYDRONIC
Connection for electrical immersion 1"1/2 Gas F
10
For models > 800 connection 2" Gas F
(14)
(1) (2) (11) (3) (13)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
16 Heat exchanger air purge 3/8" Gas F
(4) (5) (6) (16)
Volume Df De De H A H1 H2 H3 H4 H5 H6 H7
Model (vers. XXC) (vers. XXC) (vers. XXB)
WATER PRESSURE
[lt] [mm] [mm]
200 192 // // 550 1451 1552 81 316 351 401 451 511 701
TANKS
300 294 // // 650 1569 1698 149 409 444 494 544 604 794
500 504 // // 750 1861 2006 141 426 461 511 561 621 811
800 762 790 1010 // 1943 2008 113 428 473 563 653 713 863
1000 905 800 1020 // 2212 2270 112 437 482 572 662 722 922
1300 1277 950 1210 // 2193 2275 118 433 578 668 758 818 918
1500 1403 1000 1260 // 2177 2266 112 447 592 682 772 832 982
COMPRESSED AIR
2000 2024 1250 1510 // 2099 2231 134 529 649 754 859 929 1004
RECEIVERS
2500 2320 1250 1350 // 2299 2396 134 529 649 754 859 929 954
3000 2925 1250 1350 // 2799 2879 134 529 709 814 919 989 1014
4000 3776 1400 1500 // 2872 2968 117 557 737 842 947 1017 1022
5000 4995 1600 1700 // 2909 3031 94 564 734 839 944 1014 1019
2-3
H15 H16 H17 5 1 4-6 7-12 8 9 10 16 14
AND SPARE PARTS
Model 11-13
[mm] Connections Gas F
ACCESORIES
200 // 1066 1176 Øe 300 3/4" 1"1/4 1" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/4
300 // 1159 1269 Øe 300 3/4" 1"1/4 1" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/4
500 // 1380 1536 Øe 300 3/4" 1"1/4 1" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/4
800 // 1382 1538 Øe 380 3/4" 1"1/4 2" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/2
1000 // 1642 1797 Øe 380 3/4" 1"1/2 2" 1/2" 1"1/4 // 2" 3/8" 1"1/2
1300 // 1638 1793 Øe 380 1" 1"1/2 2" 1/2" 1"1/4 // 2" 3/8" 2"
1500 // 1602 1757 Øe 380 1" 1"1/2 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
TECHNICAL
2000 1524 1473 1629 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
SUPPORT
2500 1794 1710 1879 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
3000 2294 2210 2369 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
4000 2302 2225 2397 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
5000 2319 2159 2404 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
113
EXTRA 1 INOX COMPACT
316 L STAINLESS STEEL CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
3000 3072052300413 6
4000 3072052300415 8
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. Art. Nr.
5032240000107
5005000310002
5 units box
114
EXTRA 1 INOX COMPACT
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
LOW-CEILINGED ROOMS
MAX HEIGHT
250 cm
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
De
Df
(14)
1 Drain 1” Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Alternative domestic cold water circuit inlet or
H17 (11)(12) (13) 3
A
HYDRONIC
H2 (2) (3)
9 Connection for 2nd anode 1"1/4 Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
12 Connection for instrumentation 1/2" Gas F
(16) 14 Domestic hot water outlet
(14) H5 (6)
15 Drain 1" Gas F
(1) (2) (11) (3) (13)
H3 (4) 16 Heat exchanger air purge 3/8" Gas F
WATER PRESSURE
TANKS
(7) (10) (12) (8) (9)
Volume Df De H A H1 H2 H3 H4 H5 H6 H7
Model
[litres] [mm]
AND SPARE PARTS
2500 2635 1400 1500 2122 2251 117 557 677 782 887 957 982
ACCESORIES
3000 3038 1500 1600 2131 2276 106 556 736 841 946 1016 981
4000 4002 1600 1700 2409 2555 94 564 744 849 954 1024 1029
2500 1552 1501 1657 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
3000 1551 1500 1656 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
4000 1809 1732 1904 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
115
EXTRA 2 INOX
316 L STAINLESS STEEL CALORIFIERS WITH 2 EXTRACTABLE HEAT EXCHANGERS
APPLICATION
Production and storage of domestic hot water. CATHODE PROTECTION
MATERIAL Magnesium anode. - Models > 1500 n° 2 magnesium anodes.
Stainless Steel 316 L suitable for domestic hot water according to DRAIN
D.M. n. 174 dated 06.04.04. External confluence through drain connection.
HEAT EXCHANGER GASKET- FLANGE PLATE
2 Stainless steel 316L Antilegionella® heat exchangers (upper Silicone gaskets suitable for alimentary use; Mild steel exchanger
exchanger is straight and the other is bent to the bottom). head with anticorrosion treatment.
INSULATION WARRANTY
- HARD: High thermal insulation with ecological polyurethane hard foam. 5 years - See general sales conditions and warranty
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, ACCESSORIES AND SPARE PARTS
with high thermal insulation. Fire resistance class B-s2d0 according See Accessories section for the entire list.
to EN 13501.
Grey PVC external lining complete with top and flange cover
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool DISMOUNTABLE SOFT FLEECE Lower Upper ErP
Model insulation
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display
ART. NR. FOR MODELS
5005000310002 XXC
5005000310003 XXB
116
EXTRA 2 INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL CALORIFIERS WITH 2 EXTRACTABLE HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
Df
(18)
STAINLESS STEEL
CALORIFIERS
H17 (15) ASK ALWAYS FOR
(16) (17) CERTIFIED LABORATORIES
H16 (14) DATA RESULTS
H15 (13)
Drain 3/4” Gas F for models da 200 a 1000;
H11 (12) 1
(20) 1” Gas F for models > 1000
CALORIFIERS FOR
H10 (11) 2 Domestic cold water circuit inlet
HEAT PUMP
H9 (10)
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H2 (2) (3) 7-12 Connection for instrumentation 1/2” Gas F
8 Connection for magnesium anode 1"1/4 Gas F
9 Upper heat exchanger outlet
H1 (1) 10 Heat exchanger flange Upper
0 11 Upper heat exchanger inlet
Connection for 2nd anode 1”1/4 Gas F (only for models >
13
1500)
Models with 3
Connection for electrical immersion 1”1/2 Gas F For
HYDRONIC
extractable heat 14
(18) exchangers available models > 800 connection 2" Gas F
(1) (2) (15) (3) (17)
upon request
15-17 Connection for recirculation or for domestic hot water
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
(4) (5) (6) (9) (10)
TANKS
(11) (19) (20)
Volume Df De De H A H1 H2 H3 H4 H5 H6 H7 H8 H9
Model (vers. XXC) (vers. XXC) (vers. XXB)
WATER PRESSURE
[lt] [mm] [mm]
200 195 // // 550 1451 1552 81 316 351 401 451 511 701 801 851
TANKS
300 297 // // 650 1569 1698 149 409 444 494 544 604 794 894 944
500 507 // // 750 1861 2006 141 426 461 511 561 621 811 911 961
800 768 790 1010 // 1943 2008 113 428 473 563 653 713 863 1003 1093
1000 910 800 1020 // 2212 2270 112 437 482 572 662 722 922 1032 1122
1300 1283 950 1210 // 2193 2275 118 433 578 668 758 818 918 1078 1168
1500 1409 1000 1260 // 2177 2266 112 447 592 682 772 832 982 1142 1232
COMPRESSED AIR
2000 2032 1250 1510 // 2099 2231 134 529 649 754 859 929 1004 1229 1334
RECEIVERS
2500 2320 1250 1350 // 2299 2396 134 529 649 754 859 929 954 1249 1354
3000 2925 1250 1350 // 2799 2879 134 529 709 814 919 989 1014 1349 1454
4000 3776 1400 1500 // 2872 2968 117 557 737 842 947 1017 1022 1377 1482
5000 4995 1600 1700 // 2909 3031 94 564 734 839 944 1014 1019 1384 1489
2-3 4-6 7
H10 H11 H15 H16 H17 5 10 1 8 13 14 19-20 18
AND SPARE PARTS
200 901 961 // 1066 1176 Øe 300 3/4" 1"1/4 1" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/4
300 994 1054 // 1159 1269 Øe 300 3/4" 1"1/4 1" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/4
500 1011 1071 // 1380 1536 Øe 300 3/4" 1"1/4 1" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/4
800 1183 1243 // 1382 1538 Øe 380 3/4" 1"1/4 2" 1/2" 1"1/4 // 1"1/2 3/8" 1"1/2
1000 1212 1272 // 1642 1797 Øe 380 3/4" 1"1/2 2" 1/2" 1"1/4 // 2" 3/8" 1"1/2
1300 1258 1318 // 1638 1793 Øe 380 1" 1"1/2 2" 1/2" 1"1/4 // 2" 3/8" 2"
1500 1322 1382 // 1602 1757 Øe 380 1" 1"1/2 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
TECHNICAL
2000 1439 1404 1524 1473 1629 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
SUPPORT
2500 1459 1529 1794 1710 1879 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
3000 1559 1629 2294 2210 2369 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
4000 1587 1657 2302 2225 2397 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
5000 1594 1664 2319 2159 2404 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
117
EXTRA 2 INOX COMPACT
316 L STAINLESS STEEL CALORIFIERS WITH 2 EXTRACTABLE HEAT EXCHANGERS
2500 3082052300211 5 5
3000 3082052300213 6 6
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
4000 3082052300215 8 8
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. FOR MODELS Art. Nr.
5032240000107
5005000310002 XXC
5 units box
118
EXTRA 2 INOX COMPACT
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL CALORIFIERS WITH 2 EXTRACTABLE HEAT EXCHANGERS
BOLLYTERM®
CALORIFIERS
LOW-CEILINGED ROOMS
MAX HEIGHT
250 cm
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
(18) De
Df
CYLINDERS - PUFFER
MULTIFUEL ENERGY
1 Drain 1” Gas F
H17 (15)
(16) (17) 2 Domestic cold water circuit inlet
H16 (14)
(20) Alternative domestic cold water circuit inlet or
H11 (12) H15 (13) 3
connection for more boilers
H10 (11)
A
HYDRONIC
H6 (7) 7-12 Connection for instrumentation 1/2” Gas F
H5 (6)
8 Connection for magnesium anode 1"1/4 Gas F
H4 (5)
H3 (4) 9 Upper heat exchanger outlet
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
0
TANKS
14 Connection for electrical immersion 2" Gas F
WATER PRESSURE
18 Domestic hot water outlet
TANKS
19-20 Heat exchangers air purge 3/8” Gas F
Volume Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9
Model
[lt] [mm]
2500 2635 1400 1500 2122 2251 117 557 677 782 887 957 982 1257 1362
AND SPARE PARTS
3000 3030 1500 1600 2131 2276 106 556 736 841 946 1016 981 1256 1361
ACCESORIES
4000 4002 1600 1700 2409 2555 94 564 744 849 954 1024 1029 1331 1436
2-3 4-6 7
H10 H11 H15 H16 H17 5 10 1 8 13 14 19-20 18
Model 15-17 9-11 12-16
[mm] Connections Gas F
TECHNICAL
SUPPORT
2500 1537 1432 1552 1501 1657 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
3000 1466 1431 1551 1500 1656 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
4000 1716 1611 1809 1732 1904 Øe 430 1" 2" 2" 1/2" 1"1/4 1"1/4 2" 3/8" 2"
119
EXTRA1 INOX VAPORE
316 L STAINLESS STEEL CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
FOR STEAM GENERATOR
APPLICATION CATHODE PROTECTION
Production and storage of sanitary hot water. Suitable for steam Magnesium anode. Models > 1500 n° 2 magnesium anode.
generators. DRAIN
MATERIAL External confluence through drain connection.
Stainless Steel 316 L suitable for domestic hot water according to GASKET- FLANGE PLATE
D.M. n. 174 dated 06.04.04. Asbestos-free fiber gaskets
HEAT EXCHANGER Mild steel exchanger head with anticorrosion treatment.
1 stainless steel 316L straight heat exchanger suitable for steam WARRANTY
power. 5 years - See general sales conditions and warranty
INSULATION ACCESSORIES AND SPARE PARTS
- HARD: High thermal insulation with ecological polyurethane hard foam. See Accessories section for the entire list
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
with high thermal insulation. Fire resistance class B-s2d0 according
to EN 13501.
Grey PVC external lining complete with top and flange cover
HARD FOAM INSULATION
ENERGY EFFICIEN-
EXTRA 1 VAPORE XXB HEAT EXCHANGER CY CLASS
HARD FOAM SURFACE
insulation INOX 316L ErP
Model
Art. Nr. [m2]
500 3069052300123 1 C
ENERGY EFFICIEN-
EXTRA 1 VAPORE XXC HEAT EXCHANGER CY CLASS
SURFACE
www.cordivari.com/erp DISMOUNTABLE SOFT FLEECE
SOFT FLEECE INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool Art. Nr. [m2]
800 3069052300134 1,5 C
1000 3069052300135 2 C
1300 3069052300136 3 C
1500 3069052300137 3 C
2000 3069052300138 3 C
2500 3069052300109 3
3000 3069052300111 3
4000 3069052300113 4
5000 3069052300115 5
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. FOR MODELS Art. Nr.
5005000310002 XXC 5032240000107
5005000310003 XXB 5 units box
120
EXTRA1 INOX VAPORE
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
FOR STEAM GENERATOR
STORAGE HEAT EXCHANGER T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
Pmax Tmax Pmax Tmax that test procedures and
6 bar 95 °C 6 bar 165 °C Cordivari LAB are certified conforming
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
Df
(14)
STAINLESS STEEL
CALORIFIERS
H17 (11) ASK ALWAYS FOR
(12) (13) CERTIFIED LABORATORIES
H16 (10) DATA RESULTS 1 Drain
H15 (9) 2 Domestic cold water circuit inlet
Alternative domestic cold water circuit inlet or
3
connection for more boilers
CALORIFIERS FOR
4 Outlet for condense
HEAT PUMP
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H2 (2) (3) H3 (4) Connection for 2nd anode 1”1/4 Gas F (only for
9
models > 1500)
Connection for electrical immersion 1” 1/2 Gas F For
10
H1 (1) models > 800 connection 2" Gas F
0 11 Connection for recirculation or for domestic hot
13 water
12 Connection for instrumentation 1/2" Gas F
HYDRONIC
14 Domestic hot water outlet
(14)
(1) (2) (11) (3) (13)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
available on request
TANKS
(4) (5) (6)
Volume Df De De H A H1 H2 H3 H4 H5 H6 H7
Model (vers. XXC) (vers. XXC) (vers. XXB)
[lt] [mm] [mm]
WATER PRESSURE
500 504 // // 750 1861 1899 141 426 421 511 601 621 811
800 762 790 1010 // 1893 1945 113 428 473 563 653 713 863
TANKS
1000 905 800 1020 // 2212 2270 112 437 482 572 662 722 922
1300 1277 950 1210 // 2193 2275 118 433 478 568 658 718 918
1500 1403 1000 1260 // 2177 2266 112 447 592 682 772 832 982
2000 2024 1250 1510 // 2099 2231 134 529 664 754 844 904 1004
COMPRESSED AIR
2500 2320 1250 1350 // 2299 2396 134 529 664 754 844 904 954
RECEIVERS
3000 2925 1250 1350 // 2799 2880 134 529 664 754 844 904 1014
4000 3776 1400 1500 // 2872 2969 117 557 737 842 992 1017 1022
5000 4995 1600 1700 // 2909 3031 94 564 639 789 939 964 1019
2-3
H15 H16 H17 5 1 46 7-12 8 9 10 14
Model 11-13
AND SPARE PARTS
500 // 1380 1536 Øe 380 3/4" 1"1/4 DN50 PN16 1/2" 1"1/4 // 1"1/2 1"1/4
800 // 1382 1538 Øe 380 3/4" 1"1/4 DN50 PN16 1/2" 1"1/4 // 1"1/2 1"1/2
1000 // 1642 1797 Øe 380 3/4" 1"1/2 DN50 PN16 1/2" 1"1/4 // 2" 1"1/2
1300 // 1638 1793 Øe 380 1" 1"1/2 DN50 PN16 1/2" 1"1/4 // 2" 2"
1500 // 1602 1757 Øe 380 1" 1"1/2 DN50 PN16 1/2" 1"1/4 1"1/4 2" 2"
2000 1524 1473 1629 Øe 380 1" 2" DN50 PN16 1/2" 1"1/4 1"1/4 2" 2"
TECHNICAL
SUPPORT
2500 1794 1710 1879 Øe 380 1" 2" DN50 PN16 1/2" 1"1/4 1"1/4 2" 2"
3000 2294 2210 2369 Øe 380 1" 2" DN50 PN16 1/2" 1"1/4 1"1/4 2" 2"
4000 2302 2225 2397 Øe 430 1" 2" DN50 PN16 1/2" 1"1/4 1"1/4 2" 2"
5000 2319 2159 2404 Øe 430 1" 2" DN50 PN16 1/2" 1"1/4 1"1/4 2" 2"
121
VASO INERZIALE INOX
316 L STAINLESS STEEL DOMESTIC HOT WATER ACCUMULATION TANK
APPLICATION DRAIN
Domestic hot water storage External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Stainless Steel 316 L suitable for domestic hot water according to D. Silicone gaskets suitable for alimentary use; Stainless steel
M. n. 174 dated 06.04.04. exchanger head.
INSULATION WARRANTY
- HARD: High thermal insulation with ecological polyurethane hard foam. 5 years - See general sales conditions and warranty
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, ACCESSORIES AND SPARE PARTS
with high thermal insulation. Fire resistance class B-s2d0 according See Accessories section for the entire list.
to EN 13501.
Grey PVC external lining complete with top and flange cover
CATHODE PROTECTION
Magnesium anode. - Models > 1500 n° 2 magnesium anodes.
HARD FOAM INSULATION
ENERGY
VASO INERZIALE XB EFFICIENCY
CLASS
HARD FOAM
Model insulation ErP
Art. Nr.
200 3060052140422 C
300 3060052140423 C
500 3060052140424 C
www.cordivari.com/erp
On line ErP label tool ENERGY
VASO INERZIALE XC EFFICIENCY
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
CLASS
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display
ART. NR. FOR MODELS
5005000310002 XXC
5005000310003 XXB
122
VASO INERZIALE INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL DOMESTIC HOT WATER ACCUMULATION TANK
STORAGE T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
Pmax Tmax that test procedures and
6 bar 95 °C Cordivari LAB are certified conforming
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
Df
(14)
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
H17 (11) (12) (13) CERTIFIED LABORATORIES
DATA RESULTS
H16 (10)
H15 (9)
CALORIFIERS FOR
HEAT PUMP
Drain 3/4” Gas F for models da 200 a 1000;
1
H7 (8) 1” Gas F for models > 1000
H6 (7) 2
Domestic cold water circuit inlet / Delivery to external heat
exchanger
H4 (5)
3 Alternative D.H.W. inlet / To the plate heat exchanger
CYLINDERS - PUFFER
MULTIFUEL ENERGY
5 Blind flange for inspection
H2 (2) (3)
7 Connection for instrumentation 1/2" Gas F
8 Connection for magnesium anode 1”1/4 Gas F
9 Connection for 2nd anode 1”1/4 Gas F (for models > 1500)
H1 (1)
0 Connection for electrical immersion 1” 1/2 Gas F
10
For models > 800 connection 2" Gas F
11 Recirculation / from plate heat exchanger
HYDRONIC
12 Connection for instrumentation 1/2” Gas F
13 Recirculation or DHW outlet
(14)
(1) (2) (11) (3) (13) 14 Domestic hot water outlet
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
(5)
Volume Df De De H A H1 H2 H4 H6 H7
Model (vers. XC) (vers. XC) (vers. XB)
[litres] [mm]
WATER PRESSURE
200 191 // // 550 1451 1477 81 316 341 511 701
300 293 // // 650 1569 1602 149 409 434 604 794
TANKS
500 502 // // 750 1861 1899 141 426 451 621 811
800 760 790 1010 // 1943 1993 113 428 483 623 863
1000 902 800 1020 // 2212 2297 112 437 492 632 922
1300 1274 950 1210 // 2193 2255 118 433 488 628 918
1500 1399 1000 1260 // 2127 2245 112 447 502 642 982
COMPRESSED AIR
2000 2019 1250 1510 // 2049 2205 134 529 574 714 1004
2500 2320 1250 1350 // 2299 2617 134 529 574 714 954
RECEIVERS
3000 2925 1250 1350 // 2799 3065 134 529 574 714 1014
4000 3776 1400 1500 // 2872 3195 117 557 602 742 1022
5000 4995 1600 1700 // 2909 3320 94 564 609 749 1019
2-3
H15 H16 H17 5 1 7-12 8 9 10 14
AND SPARE PARTS
Model 11-13
[mm] Connections Gas F
ACCESORIES
200 // 1066 1176 Øe 180 3/4" 1"1/4 1/2" 1"1/4 // 1"1/2 1"1/4
300 // 1159 1269 Øe 180 3/4" 1"1/4 1/2" 1"1/4 // 1"1/2 1"1/4
500 // 1380 1536 Øe 180 3/4" 1"1/4 1/2" 1"1/4 // 1"1/2 1"1/4
800 // 1382 1538 Øe 240 3/4" 1"1/4 1/2" 1"1/4 // 1"1/2 1"1/2
1000 // 1642 1797 Øe 240 3/4" 1"1/2 1/2" 1"1/4 // 2" 1"1/2
1300 // 1638 1793 Øe 240 1" 1"1/2 1/2" 1"1/4 // 2" 2"
1500 // 1602 1757 Øe 240 1" 1"1/2 1/2" 1"1/4 1"1/4 2" 2"
TECHNICAL
2000 1524 1473 1629 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
SUPPORT
2500 1794 1710 1879 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
3000 2294 2210 2369 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
4000 2302 2225 2397 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
5000 2319 2159 2404 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
123
VASO INERZIALE INOX COMPACT
316 L STAINLESS STEEL DOMESTIC HOT WATER ACCUMULATION TANK
APPLICATION DRAIN
Domestic hot water storage. Suitable for low-ceilinged room. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Stainless Steel 316 L suitable for domestic hot water according to Silicone gaskets suitable for alimentary use; Stainless steel
D. M. n. 174 dated 06.04.04. exchanger head.
INSULATION (DISMOUNTABLE) WARRANTY
NOFIRE® polyester fleece 100% made of recyclable material, with 5 years - See general sales conditions and warranty
high thermal insulation. Fire resistance class B-s2d0 according to ACCESSORIES AND SPARE PARTS
EN 13501. See Accessories section for the entire list.
Grey PVC external lining complete with top and flange cover
CATHODE PROTECTION
2 magnesium anodes.
SOFT FLEECE INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
3000 3060052140413
4000 3060052140415
Accessories on request
“Easy Control” Electronic Display
ART. NR. FOR MODELS
5005000310002 XC
124
VASO INERZIALE INOX COMPACT
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL DOMESTIC HOT WATER ACCUMULATION TANK
STORAGE
Pmax Tmax
6 bar 95 °C SUITABLE FOR
BOLLYTERM®
CALORIFIERS
LOW-CEILINGED ROOMS
MAX HEIGHT
250 cm
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
De
Df
(14)
1 Drain 1” Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2 Domestic cold water circuit inlet / Delivery to external heat exchanger
H17 (11) (12) (13)
H15 (9)
H16 (10) 3 Domestic cold water circuit inlet / To the plate heat exchanger
HYDRONIC
H2 (2) (3)
10 Connection for electrical immersion 2" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
COMPLETE YOUR SYSTEM WITH
(14) THE NEW PRS MODULE (FOR
(1) (2) (11) (3) (13) IMMEDIATE DHW PREPARATION)
WATER PRESSURE
SEE HYDRONIC
SECTION
TANKS
(7) (10) (12) (8) (9)
Volume Df De H A H1 H2 H4 H6 H7
Model
[lt] [mm]
2500 2635 1400 1500 2122 2542 117 557 602 742 982
AND SPARE PARTS
3000 3038 1500 1600 2131 2606 106 556 601 741 981
ACCESORIES
4000 4002 1600 1700 2409 2892 94 564 609 749 1029
2500 1552 1501 1657 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
3000 1551 1500 1656 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
4000 1809 1732 1904 Øe 240 1" 2" 1/2" 1"1/4 1"1/4 2" 2"
125
BOLLY® 1 ST INOX
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
APPLICATION
Production and storage of domestic hot water. CATHODE PROTECTION
MATERIAL Magnesium anode.
Stainless Steel 316 L suitable for domestic hot water according to DRAIN
D.M. n. 174 dated 06.04.04. External confluence through drain connection.
HEAT EXCHANGER GASKET- FLANGE PLATE
1 stainless steel 316L fixed heat exchanger Silicone gaskets suitable for alimentary use; Stainless steel
INSULATION exchanger head.
- HARD: High thermal insulation with ecological polyurethane hard foam. WARRANTY
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, 5 years - See general sales conditions and warranty
with high thermal insulation. Fire resistance class B-s2d0 according ACCESSORIES AND SPARE PARTS
to EN 13501. See Accessories section for the entire list.
Grey PVC external lining complete with top and flange cover
S T O C K
grey
AVAILABILITY
ENERGY
HARD FOAM INSULATION
www.cordivari.com/erp
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool
ENERGY
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. FOR MODELS Art. Nr.
5005000310002 XC 5032240000107
5005000310003 XB 5 units box
126
BOLLY® 1 ST INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
Df
CALORIFIERS
ASK ALWAYS FOR
(12) CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
2 Domestic cold water circuit inlet
H10 (9)
3 Primary circuit outlet
H7 (8) 4 Connection for instrumentation 1/2" Gas F
H5 (6) H6 (7)
Blind flange for inspection Ø 120 mm
5
For models >1000 connection Ø 160 mm
CYLINDERS - PUFFER
MULTIFUEL ENERGY
6 Primary circuit inlet
7 Connection for magnesium anode 1" 1/4 Gas F
Connection for electrical immersion 1” 1/2 Gas F
8
For models >500 connection 2” Gas F
H4 (4) (5) 9 Recirculation
H3 (3) 10 Connection for instrumentation 1/2" Gas F
H2 (2)
Connection for 2nd anode 1"1/4 Gas F
HYDRONIC
H1 (1) 11
(only for models da 800 a 2000)
0
12 Domestic hot water outlet
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Deflettore
Deflector
(2)
INERTIAL
TANKS
(3) (6) (9) (1) (15)
(5) (7) (14)
(11) (12)
WATER PRESSURE
TANKS
HARD FOAM INSULATION (XB)
Model Volume Df De H A H1 H2 H3 H4 H5 H6 H7 H10 H12 1 2 3-6 9 12
[lt] [mm] Connections Gas F
COMPRESSED AIR
150 149 400 500 1426 1511 71 199 276 316 766 816 886 1066 1186 1/2" 3/4" 1" 3/4" 1"
RECEIVERS
200 191 450 550 1446 1547 71 209 296 326 822 866 926 1100 1206 1/2" 3/4" 1" 3/4" 1"
300 293 550 650 1501 1636 76 236 326 386 847 886 946 1116 1236 1/2" 1" 1" 1" 1"
400 425 600 700 1776 1909 71 246 346 395 998 1026 1086 1331 1486 1/2" 1" 1" 1" 1"
500 503 650 750 1796 1946 71 256 356 411 1046 1086 1154 1341 1496 1/2" 1" 1" 1" 1"
AND SPARE PARTS
127
BOLLY® 2 ST INOX
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
APPLICATION
Production and storage of domestic hot water. CATHODE PROTECTION
MATERIAL Magnesium anode.
Stainless Steel 316 L suitable for domestic hot water according to DRAIN
D.M. n. 174 dated 06.04.04. External confluence through drain connection.
HEAT EXCHANGER GASKET- FLANGE PLATE
2 stainless steel 316L fixed heat exchangers Silicone gaskets suitable for alimentary use; Stainless steel
INSULATION exchanger head.
- HARD: High thermal insulation with ecological polyurethane hard foam. WARRANTY
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, 5 years - See general sales conditions and warranty
with high thermal insulation. Fire resistance class B-s2d0 according ACCESSORIES AND SPARE PARTS
to EN 13501. See Accessories section for the entire list.
Grey PVC external lining complete with top and flange cover
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
www.cordivari.com/erp
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool
STAINLESS STEEL HEAT ENERGY
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. FOR MODELS Art. Nr.
5005000310002 XC 5032240000107
5005000310003 XB 5 units box
128
BOLLY® 2 ST INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER WITH 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
De
STAINLESS STEEL
Df
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
(15) DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
H10 (11) 2 Domestic cold water circuit inlet
3 Primary circuit outlet
H9 (10)
H8 (9) H7 (8) 4 Connection for instrumentation 1/2"Gas F
H5 (6) H6 (7)
Blind flange for inspection Ø 120 mm
5
For models >1000 connection Ø 160 mm
CYLINDERS - PUFFER
MULTIFUEL ENERGY
6 Primary circuit inlet 1” 1/4 Gas F
7 Connection for magnesium anode 1" 1/4 Gas F
Connection for electrical immersion 1” 1/2 Gas F
8
For models >500 connection 2” Gas F
H4 (4) (5) 9 Upper heat exchanger outlet
H3 (3) 10 Connection for instrumentation 1/2”Gas F
H2 (2)
HYDRONIC
11 Recirculation
H1 (1)
0 12 Upper heat exchanger inlet
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
(2) Deflettore
Deflector 13 Connection for instrumentation 1/2”Gas F
Connection for 2nd anode 1”1/4 Gas F (only for models >
14
500)
15 Domestic hot water outlet
INERTIAL
TANKS
(3) (6) (9) (1) (15)
(11) (12) (5) (7) (14)
WATER PRESSURE
TANKS
HARD FOAM INSULATION (XB)
3-6
COMPRESSED AIR
1300 1272 950 1210 2213 2269 118 313 438 483 1213 1248 1318 1368 1427 1578 1788 1798 1" 1"1/4 2" 1"1/4 2" 2"
1500 1398 1000 1260 2197 2260 93 327 452 497 1227 1242 1302 1332 1462 1542 1752 1762 1" 2" 2" 1"1/4 2" 2"
2000 2018 1250 1510 2070 2204 85 350 475 520 1035 1065 1160 1215 1345 1390 1565 1575 1" 2" 2" 1"1/4 2" 2"
129
BOLLY® 1 XL INOX
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER
WITH 1 HIGH PERFORMACE FIXED HEAT EXCHANGER
APPLICATION
Production and storage of domestic hot water. DRAIN
MATERIAL External confluence through drain connection.
Stainless Steel 316 L suitable for domestic hot water according to GASKET- FLANGE PLATE
D.M. n. 174 dated 06.04.04. Silicone gaskets suitable for alimentary use; Stainless steel
HEAT EXCHANGER exchanger head.
1 stainless steel 316L fixed heat exchanger WARRANTY
INSULATION 5 years - See general sales conditions and warranty
- HARD: High thermal insulation with ecological polyurethane hard foam. ACCESSORIES AND SPARE PARTS
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, See Accessories section for the entire list.
with high thermal insulation. Fire resistance class B-s2d0 according
to EN 13501.
Grey PVC external lining complete with top and flange cover
CATHODE PROTECTION
Magnesium anode.
HARD FOAM INSULATION
ENERGY
BOLLY® 1 XL XB HEAT EXCHANGER EFFICIENCY
CLASS
SURFACE
HARD FOAM INOX 316L
Model insulation ErP
Art. Nr. [m2]
200 3105052300001 1,95 B
300 3105052300002 3,5 B
500 3105052300003 5,5 C
www.cordivari.com/erp
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
BOLLY® 1 XL XC HEAT EXCHANGER EFFICIENCY
CLASS
SURFACE
DISMOUNTABLE SOFT FLEECE INOX 316L
Model insulation ErP
Art. Nr. [m2]
800 3105052300016 6 C
1000 3105052300017 6,8 C
200 67 120 90 60
300 72 129 97 64
500 114 204 153 102
800 232 416 312 208
1000 346 620 465 310
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. FOR MODELS Art. Nr.
5005000310002 XC 5032240000107
5005000310003 XB 5 units box
130
BOLLY® 1 XL INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER
WITH 1 HIGH PERFORMACE FIXED HEAT EXCHANGER
BOLLYTERM®
that test procedures and
CALORIFIERS
6 bar 95 °C 12 bar 110 °C Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
De
CALORIFIERS
Df ASK ALWAYS FOR
CERTIFIED LABORATORIES
(12) DATA RESULTS
1 Drain
CALORIFIERS FOR
HEAT PUMP
2 Domestic cold water circuit inlet
H10 (10) (11) 3 Primary circuit outlet 1” 1/4 Gas F
H9 (9) 4 Connection for instrumentation 1/2" Gas F
A
CYLINDERS - PUFFER
H6 (6) H7 (7)
MULTIFUEL ENERGY
7 Connection for magnesium anode 1" 1/4 Gas F
H Connection for electrical immersion 1” 1/2 Gas F
8
For models >500 connection 2” Gas F
9 Recirculation 1” F
10 Connection for instrumentation 1/2" Gas F
H4 (4)(5) Connection for 2nd anode 1"1/4 Gas F (only for models
11
HYDRONIC
> 500)
H3 (3)
H2 (2) 12 Domestic hot water outlet
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)
0
(2)
INERTIAL
TANKS
(1)
(3) (6) (9) (5) (7) (11)
(12)
WATER PRESSURE
TANKS
(4) (8) (10)
1000 902 800 1020 2192 2231 112 317 412 477 1225 1282 1337 1557 1792 1792 3/4" 1" 1/4 1” 1/4
131
BOLLY® 2 XL INOX
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER
WITH 2 HIGH PERFORMACE FIXED HEAT EXCHANGERS
APPLICATION
Production and storage of domestic hot water. DRAIN
MATERIAL External confluence through drain connection.
Stainless Steel 316 L suitable for domestic hot water according to GASKET- FLANGE PLATE
D.M. n. 174 dated 06.04.04. Silicone gaskets suitable for alimentary use; Stainless steel
HEAT EXCHANGER exchanger head.
2 stainless steel 316L fixed heat exchangers WARRANTY
INSULATION 5 years - See general sales conditions and warranty
- HARD: High thermal insulation with ecological polyurethane hard foam. ACCESSORIES AND SPARE PARTS
- SOFT: NOFIRE® polyester fleece 100% made of recyclable material, See Accessories section for the entire list.
with high thermal insulation. Fire resistance class B-s2d0 according
to EN 13501.
Grey PVC external lining complete with top and flange cover
CATHODE PROTECTION
Magnesium anode.
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
www.cordivari.com/erp
On line ErP label tool
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
SOFT FLEECE INSULATION
Accessories on request
“Easy Control” Electronic Display Thermometer
ART. NR. FOR MODELS Art. Nr.
5005000310002 XC 5032240000107
5005000310003 XB 5 units box
132
BOLLY® 2 XL INOX
EXTRA- BOLLY®
CALORIFIERS
316 L STAINLESS STEEL DOMESTIC HOT WATER CALORIFIER
WITH 2 HIGH PERFORMACE FIXED HEAT EXCHANGERS
BOLLYTERM®
that test procedures and
CALORIFIERS
6 bar 95 °C 12 bar 110 °C Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
1 Drain
Df
CALORIFIERS FOR
2 Domestic cold water circuit inlet
HEAT PUMP
(15) 3 Primary circuit outlet 1” 1/4 Gas F
4 Connection for instrumentation 1/2" Gas F
5 Blind flange for inspection Ø 120 mm
H13 (13) (14) 6 Primary circuit inlet 1” 1/4 Gas F
H12 (12)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
7 Connection for magnesium anode 1" 1/4 Gas F
HYDRONIC
H6 (6)
13 Connection for instrumentation 1/2" Gas F
H4 (4) (5)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
14 Connection for 2nd anode 1"1/4 Gas F (only for models > 500)
H3 (3)
H2 (2) 15 Domestic hot water outlet
H1 (1)
0
INERTIAL
TANKS
(2)
WATER PRESSURE
(11) (12) (5) (7) (14)
(14)
TANKS
(4) (8) (10)
(13) COMPRESSED AIR
RECEIVERS
500 503 750 1796 1946 71 256 356 411 601 686 766 810 1299 1148 1485 1496 1/2" 1" 1"
800 759 790 1010 1943 1986 114 323 423 478 664 696 756 800 1383 1213 1548 1568 3/4" 1" 1"1/4
1000 902 800 1020 2192 2231 112 317 412 477 873 908 963 1008 1564 1452 1756 1792 3/4" 1"1/4 1"1/4
133
COMBI 1 INOX
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL TANK IN TANK CALORIFIER
D.H.W. STORAGE
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Volume Surface ErP
Model insulation
Art. Nr. [lt] [m2]
800 3270162314053 191 1,6 C
1000 3270162314054 226 1,8 C
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Chain magnesium anode (connection 3/4”) Buffer tanks connecting kit
Art. Nr. Art. Nr. For models Art. Nr. Connection
5032240000107 5200000041007 800,1000 5006170001001 1” 1/2
5 units box 5200000041016 500,600 Stainless steel extensible
N° 2 chain anodes + insulated connecting kit - (200 ÷ 400 mm)
cap + gasket
134
COMBI 1 INOX
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL TANK IN TANK CALORIFIER
TECHNICAL D.H.W.
STORAGE STORAGE
Pmax Tmax Pmax Tmax
BOLLYTERM®
CALORIFIERS
3 bar 99 °C 6 bar 95 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
Df
CALORIFIERS FOR
HEAT PUMP
(24)
H12 (16)
(17) (18)
H11 (15)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H9 (12) (13)
H8 (10) 1-3 Heating return/To Generator 1"1/2 Gas F
A
H7 (9)
5 Connection for instrumentation 1/2" Gas F
H5 (6) (7) 6-7 Heating return/To Generator 1"1/2 Gas F
H4 (5)
HYDRONIC
9 Electrical immersion 1"1/2 Gas F
10 Connection for instrumentation 1/2" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H2 (1) (2) (3) 12-13 Heating return/To additional generator/Heating delivery 1"1/2 Gas F
INERTIAL
TANKS
17 Connection for instrumentation 1/2" Gas F
19 Air purge 1/2" Gas F
(20) (23)
(19) 20 Domestic hot water inlet 3/4" Gas F
WATER PRESSURE
(1) (6) 22 Recirculation 3/4" Gas F
(3) (7)
(21)
TANKS
(12) (16) (13) (18) 23 Connection for instrumentation 1/2" Gas F
800 803 950 1890 2111 265 584 690 823 1115 1332 1541
1000 944 950 2180 2374 265 656 787 998 1309 1588 1831
135
COMBI 2 INOX
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL TANK IN TANK CALORIFIER
AND 1 FIXED HEAT EXCHANGER
APPLICATION INSULATION
Heating hot water storage and D.H.W. production. High thermal insulation with ecological polyurethane hard foam.
MATERIAL Grey PVC external lining
Buffer tank:: Mild steel construction with exterior paint. No anti- CATHODE PROTECTION
corrosion treatment required due to the buffer’s closed circuit system. Chain magnesium anode
D.H.W. storage: 316L Stainless steel WARRANTY
HEAT EXCHANGER 5 years - See general sales conditions and warranty
1 fixed heat exchanger. ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Multi-Heat Energy tanks Combi2 are used in units with a typically
discontinuous energy source for double use: heating systems and
domestic hot water systems.
D.H.W. STORAGE
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
DISMOUNTABLE HARD FOAM Volume Surface Volume Surface ErP
Model insulation
Art. Nr. [lt] [m2] [lt] [m2]
800 3270162314153 191 1,6 20 3,1 C
1000 3270162314154 226 1,8 24 3,7 C
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Chain magnesium anode (connection 3/4”) Buffer tanks connecting kit
Art. Nr. Art. Nr. For models Art. Nr. Connection
5032240000107 5200000041007 800,1000 5006170001001 1” 1/2
5 units box 5200000041016 500,600 Stainless steel extensible
N° 2 chain anodes + insulated connecting kit - (200 ÷ 400 mm)
cap + gasket
136
COMBI 2 INOX
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL TANK IN TANK CALORIFIER
AND 1 FIXED HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
Pmax Tmax Pmax Tmax Pmax Tmax
3 bar 99 °C 6 bar 95 °C 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as
CALORIFIERS
ASK ALWAYS FOR
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
De
HEAT PUMP
Df
(24)
1-3 Heating return/To Generator 1"1/2 Gas F
H12 (16)
CYLINDERS - PUFFER
(17) (18)
MULTIFUEL ENERGY
2 Connection for instrumentation 1/2" Gas F
4 Lower fixed heat exchanger outlet 1" Gas F
H11 (15)
5 Connection for instrumentation 1/2" Gas F
6-7 Heating return/To Generator 1"1/2 Gas F
H9 (12) (13)
H8 (10) 8 Lower fixed heat exchanger inlet 1" Gas F
A
HYDRONIC
H6 (8) 12-
H5 (6) (7) Heating return/To additional generator/Heating delivery 1"1/2 Gas F
13
H4 (5) 15 Connection for instrumentation 1/2" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
16-
Heating return/Heating delivery 1"1/2 Gas F
18
H3 (4) 17 Connection for instrumentation 1/2" Gas F
H2 (1) (2) (3)
19 Air purge 1/2" Gas F
INERTIAL
TANKS
0 20 Domestic hot water inlet 3/4" Gas F
21 Domestic hot water outlet 3/4" Gas F
22 Recirculation 3/4" Gas F
23 Connection for instrumentation 1/2" Gas F
WATER PRESSURE
(20) (23)
(19) 24 Chain magnesium anode 3/4” Gas F
TANKS
(24) (22)
(1) (6) (3) (7)
(21)
(12) (16) (13) (18)
(2) (5) (9) (4) (8)
COMPRESSED AIR
100°
AND SPARE PARTS
ACCESORIES
800 803 950 1890 2111 265 584 690 823 1115 1332 1541
1000 944 950 2180 2374 265 656 787 998 1309 1588 1831
137
COMBI 3 INOX
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL TANK IN TANK CALORIFIER
AND 2 FIXED HEAT EXCHANGERS
APPLICATION INSULATION
Heating hot water storage and D.H.W. production. High thermal insulation with ecological polyurethane hard foam.
MATERIAL Grey PVC external lining
Buffer tank: Mild steel construction with exterior paint. No anti- CATHODE PROTECTION
corrosion treatment required due to the buffer’s closed circuit system. Chain magnesium anode
D.H.W. storage: 316L Stainless steel WARRANTY
HEAT EXCHANGER 5 years - See general sales conditions and warranty
2 fixed heat exchangers. ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Multi-Heat Energy tanks Combi3 are used in units with a typically
discontinuous energy source for double use: heating systems and
domestic hot water systems.
D.H.W. STORAGE
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
DISMOUNTABLE HARD FOAM Volume Surface Volume Surface Volume Surface ErP
Model insulation
Art. Nr. [lt] [m2] [lt] [m2] [lt] [m2]
800 3270162314253 191 1,6 16 2,4 20 3,1 C
1000 3270162314254 226 1,8 20 3,1 24 3,7 C
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Chain magnesium anode (connection 3/4”) Buffer tanks connecting kit
Art. Nr. Art. Nr. For models Art. Nr. Connection
5032240000107 5200000041007 800,1000 5006170001001 1” 1/2
5 units box 5200000041016 500,600 Stainless steel extensible
N° 2 chain anodes + insulated connecting kit - (200 ÷ 400 mm)
cap + gasket
138
COMBI 3 INOX
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL TANK IN TANK CALORIFIER
AND 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
CALORIFIERS
Pmax Tmax Pmax Tmax Pmax Tmax
3 bar 99 °C 6 bar 95 °C 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
CALORIFIERS FOR
Df
HEAT PUMP
(24)
H12 (16) 1-3 Heating return/To Generator 1"1/2 Gas F
(17) (18) 2 Connection for instrumentation 1/2" Gas F
H10 (14)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H11 (15) 4 Lower fixed heat exchanger outlet 1" Gas F
5 Connection for instrumentation 1/2" Gas F
H9 (12) (13) 6-7 Heating return/To Generator 1"1/2 Gas F
H8 (10) (11)
A
HYDRONIC
H4 (5) 11 Upper fixed heat exchanger outlet 1" Gas F
INERTIAL
TANKS
17 Connection for instrumentation 1/2" Gas F
19 Air purge 1/2" Gas F
WATER PRESSURE
21 Domestic hot water outlet 3/4" Gas F
(24) (22) 22 Recirculation 3/4" Gas F
TANKS
(1) (6) (3) (7) 23 Connection for instrumentation 1/2" Gas F
(12) (16) (21)
(13) (18) 24 Chain magnesium anode 3/4” Gas F
(2) (5) (9) (10) (4) (8)
(15) (17) (11) (14)
COMPRESSED AIR
RECEIVERS
100°
AND SPARE PARTS
ACCESORIES
800 803 950 1890 2111 265 278 584 690 762 823 988 1115 1428 1332 1541
1000 944 950 2180 2374 265 284 656 787 953 998 1188 1309 1748 1588 1831
139
140
141
HEAT PUMP
CALORIFIERS FOR
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
Calorifiers for
HEAT
PUMP
142
EXTRA- BOLLY®
CALORIFIERS
NEW BOLLY® PDC RANGE
Bolly® PDC is the resu
result of a continuous research aimed to develop a calorifier unique in its field. It is in fact
the only patented syst
system of thermal exchange actually on the market, specifically conceived for installation
and heat pumps of latest generation.
The excha
exchange and stratification system is conceived to self-balance: only part of the heated
BOLLYTERM®
wate
water, proportionate to the temperature achieved during the thermal exchange, is
CALORIFIERS
iinserted in the tank from the top. This way the water inserted in the upper part is at
PATENTED
maximum desired temperature while fresh water coming from the lower part of the
HEAT-EXCHANGE
MODULE tank goes to the exchanger.
This lead to many advantages such as the increased efficiency of the heat pump
C.o.p, the achievement of a perfect thermal stratification, that allows to profit
STAINLESS STEEL
immediately of the heated water. This also allows to heat only part of the tank
CALORIFIERS
reducing energy waste.
The innovative Bolly® PDC, combined with an heat pump and thanks to the new
patented exchange group is able to guarantee 30 % higher performances compared
to a generic, traditional calorifier in terms of ignition time and thermal exchange
efficiency.
CALORIFIERS FOR
Laboratory tests and researches conducted on the stratification process confirm the
HEAT PUMP
use of Bolly® PDC in a heat pump installation means an increased comfort and about a 15% reduction of electric consumption while
extending the generator lifecycle reducing its turning on/off.
CYLINDERS - PUFFER
MULTIFUEL ENERGY
65
60
-30% ignition time and consequent better
55
efficiency of HP in heating/cooling phase.
50
HYDRONIC
35
30
25
15 70 liters Optimizing the time necessary for the HP for
minutes of DHW
20
heating and cooling the room.
15
INERTIAL
TANKS
BOLLY® PDC
WATER PRESSURE
Upper loading and improved thermal stratification thanks to the patented heat
exchanger group.
TANKS
500 l. standard tank heating, connected to 12kW heat pump
70
T1 HEAT PUMP T2 HEAT PUMP DHW Temperature
65
60
COMPRESSED AIR
55
50
efficiency decrease. 35
AND SPARE PARTS
30
ACCESORIES
20
storage tank 10
00:00:00 00:15:00 00:30:00 00:45:00
TECHNICAL
SUPPORT
143
CALORIFIERS FOR HEAT PUMP
RANGE
DHW
production
Number of heat
exchangers / /
Energy source
Energy efficiency
C B-C
class
144
EXTRA- BOLLY®
CALORIFIERS
ErP
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
TERMOMAS® PDC ECO-COMBI PDC
CYLINDERS - PUFFER
MULTIFUEL ENERGY
- Spiral fixed heat exchanger
- MACS® module for DHW production
- Corrugated 316L stainless steel pipe for D.H.W. production
/ /
HYDRONIC
INERTIAL
TANKS
C C
WATER PRESSURE
Polyurethane hard foam Polyurethane hard foam
TANKS
145
BOLLY® 1 PDC
POLYWARM® COATED DHW PRODUCTION TANK FOR HEAT PUMP
POLYWARM®
HARD FOAM INSULATION
ENERGY
BOLLY® 1 PDC WB EFFICIENCY
CLASS
HARD FOAM Heat pump max
Model insulation output ErP
Art. Nr. [kW]
www.cordivari.com/erp 300 3105162320203 26 C
500 3105162320205 26 C
On line ErP label tool 800 3105162320206 35 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
PATENTED EXCHANGE -30% reduction of ignition time and mayor comfort in using the heat pump in heating
SYSTEM and cooling systems
70lt of DHW in only 15 min, with the possibility of heating only the necessary water
volume
Energy focused where needed: all the energy produced with the heat pump
concentrated in the upper part of the tank.
Accessories on request
Thermometer Titanium electronic anode Electrical immersion heaters
Art. Nr. Output
5032240000107 Art. Nr. Model Art. Nr.
[kW]
5 units box 5200000000008 300 5221000000064 2
5200000000009 500
5200000000011 800
Antilegionellosis kit
146
BOLLY® 1 PDC
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DHW PRODUCTION TANK FOR HEAT PUMP
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
CALORIFIERS
DATA RESULTS
De
CALORIFIERS FOR
(15)
HEAT PUMP
H14 (16) (17)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H11 (11)
H10 (10)
H8 (8)
H7 (7) H7 (7)
H
HYDRONIC
H4 (5) H4 (4) (5)
H2 (2) H2 (2)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)
0
INERTIAL
TANKS
(4) (8) (13) 1 Drain 11 Recirculation 1" Gas F
(10)
(16) 2 Domestic cold water circuit inlet 1" Gas F 13 Connection for instrumentation 1/2" Gas F
WATER PRESSURE
(1)
(5) (7) (11) 4 Connection for instrumentation 1/2" Gas F 14 Connection for 2nd anode 1"1/4 Gas F (≥ 800.)
(14)
TANKS
(16)
(17) 5 Blind flange for inspection 15 Domestic hot water outlet 1"1/4 Gas F
7 Connection for magnesium anode 1"1/4 Gas F 16 Primary circuit inlet 1" Gas M
(2) 8 Connection for electrical immersion 17 Primary circuit outlet 1" Gas M
COMPRESSED AIR
RECEIVERS
Volume De H A H1 H2 H4 H7
Model
[lt] [mm]
300 291 650 1680 1800 71 246 381 871
AND SPARE PARTS
147
BOLLY® 2 PDC
POLYWARM® COATED DHW PRODUCTION TANK FOR HEAT PUMP
WITH 1 HEAT EXCHANGER
APPLICATION CATHODE PROTECTION
Production and storage of domestic hot water. Magnesium anode.
MATERIAL DRAIN
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 External confluence through drain connection.
- UBA - WRAS) GASKET- FLANGE PLATE
EXCHANGE MODULE Silicone gaskets suitable for alimentary use. Inspection flange plate
System equipped with exchanger at heat charge from the top. WARRANTY
HEAT EXCHANGER 5 years (tank)
1 Polywarm® coated fixed heat exchanger See general sales conditions and warranty for electrical parts.
INSULATION ACCESSORIES AND SPARE PARTS
High thermal insulation with ecological polyurethane hard foam. See Accessories section for the entire list.
Grey PVC external lining
POLYWARM®
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® 2 PDC WB Heat pump SURFACE CLASS
HARD FOAM max output
Model insulation [m2] ErP
Art. Nr. [kW]
www.cordivari.com/erp 300 3135162320403 26 1,2 C
500 3135162320405 26 1,8 C
On line ErP label tool
800 3135162320406 35 2,7 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
PATENTED EXCHANGE -30% reduction of ignition time and mayor comfort in using the heat pump in heating
SYSTEM and cooling systems
70lt of DHW in only 15 min, with the possibility of heating only the necessary water
volume
Energy focused where needed: all the energy produced with the heat pump
concentrated in the upper part of the tank.
Accessories on request
Thermometer Titanium electronic anode Electrical immersion
Art. Nr. Output
5032240000107 Art. Nr. Model Art. Nr.
[kW]
5 units box 5200000000008 300 5221000000064 2
5200000000009 500
5200000000011 800
Antilegionellosis kit
148
BOLLY® 2 PDC
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DHW PRODUCTION TANK FOR HEAT PUMP
WITH 1 HEAT EXCHANGER
STORAGE EXCHANGE MODULE FIXED HEAT EXCHANGER
Pmax Tmax Pmax Tmax Pmax Tmax
10 bar 90 °C 10 bar 110 °C 12 bar 110 °C
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
ASK ALWAYS FOR
CALORIFIERS
CERTIFIED LABORATORIES
DATA RESULTS
De
Df
CALORIFIERS FOR
HEAT PUMP
(15)
H14 (16) (17)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
(14)
H11 (11)
H10 (10)
H8 (8)
H7 (7) H6 (6) H7 (7)
HYDRONIC
H4 (5) H4 (4) (5)
H3 (3)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H2 (2) H2 (2)
H1 (1)
0
INERTIAL
TANKS
1 Drain 8 Connection for electrical immersion
2 Domestic cold water circuit inlet 1" Gas F 11 Recirculation 1" Gas F
(4) (8) (13)
(10) 3 Heat exchanger outlet 13 Connection for instrumentation 1/2" Gas F
WATER PRESSURE
(16)
(1) (3) (6) 4 Connection for instrumentation 1/2" Gas F 14 Connection for 2nd anode 1"1/4 Gas F (≥ 800.)
TANKS
(5) (7) (11)
(14)
(16) 5 Blind flange for inspection 15 Domestic hot water outlet 1"1/4 Gas F
(17)
6 Heat exchanger inlet 16 Heat exchanger inlet 1" Gas M
7 Connection for magnesium anode 1"1/4 Gas F 17 Heat exchanger outlet 1" Gas M
COMPRESSED AIR
(2)
RECEIVERS
Volume De H A H1 H2 H3 H4 H6 H7
Model
[lt] [mm]
300 291 650 1680 1800 71 246 311 381 832 871
AND SPARE PARTS
500 497 750 1970 2110 71 266 341 406 1031 1071
ACCESORIES
800 789 900 2360 2530 101 343 428 483 1181 1243
300 931 1076 1101 1221 1522 1"1/4 Øi 120 1"1/2 1"
SUPPORT
500 1139 1291 1326 1471 1812 1"1/4 Øi 120 1"1/2 1"
800 1308 1573 1598 1788 2196 3/4" Øi 160 2" 1"1/4
149
BOLLY® 3 PDC
POLYWARM® COATED DHW PRODUCTION TANK FOR HEAT PUMP
WITH 2 HEAT EXCHANGERS
APPLICATION CATHODE PROTECTION
Production and storage of domestic hot water. Magnesium anode.
MATERIAL DRAIN
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 External confluence through drain connection.
- UBA - WRAS) GASKET- FLANGE PLATE
EXCHANGE MODULE Silicone gaskets suitable for alimentary use. Inspection flange plate
System equipped with exchanger at heat charge from the top. WARRANTY
HEAT EXCHANGERS 5 years (tank)
2 Polywarm® coated fixed heat exchangers See general sales conditions and warranty for electrical parts.
INSULATION ACCESSORIES AND SPARE PARTS
High thermal insulation with ecological polyurethane hard foam. See Accessories section for the entire list.
Grey PVC external lining
POLYWARM®
HARD FOAM INSULATION
ENERGY
BOLLY® 3 PDC WB Heat pump
HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM max output
Upper Lower ErP
Model insulation
Art. Nr. [kW] [m2]
www.cordivari.com/erp 300 3135162320452 26 0,7 1,2 C
500 3135162320453 26 1,2 1,8 C
On line ErP label tool
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
PATENTED EXCHANGE -30% reduction of ignition time and mayor comfort in using the heat pump in heating
SYSTEM and cooling systems
70lt of DHW in only 15 min, with the possibility of heating only the necessary water
volume
Energy focused where needed: all the energy produced with the heat pump
concentrated in the upper part of the tank.
Accessories on request
Thermometer Titanium electronic anode Electrical immersion
Art. Nr. Output
5032240000107 Art. Nr. Model Art. Nr.
[kW]
5 units box 5200000000008 300 5221000000064 2
5200000000009 500
Antilegionellosis kit
150
BOLLY® 3 PDC
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED DHW PRODUCTION TANK FOR HEAT PUMP
WITH 2 HEAT EXCHANGERS
STORAGE EXCHANGE MODULE FIXED HEAT EXCHANGER
Pmax Tmax Pmax Tmax Pmax Tmax
10 bar 90 °C 10 bar 110 °C 12 bar 110 °C
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
CALORIFIERS
DATA RESULTS
CALORIFIERS FOR
De
HEAT PUMP
(15)
H14 (16) (17)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H12 (12) H13 (13)
H11 (11)
H10 (10)
H9 (9) H8 (8)
H7 (7) H6 (6) H7 (7)
HYDRONIC
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
H1 (1)
TANKS
0
WATER PRESSURE
(4) (8) (13) 2 Domestic cold water circuit inlet 1" Gas F 10 Connection for instrumentation 1/2" Gas F
(10)
TANKS
3 Primary circuit outlet 11 Recirculation 1" Gas F
(16)
(1) (3) (6)
(5) (7) (11) 4 Connection for instrumentation 1/2" Gas F 12 Upper heat exchanger inlet
(16) (9) (12)
(17) 5 Blind flange for inspection 13 Connection for instrumentation 1/2" Gas F
COMPRESSED AIR
(2) 7 Connection for magnesium anode 1"1/4 Gas F 16 Primary circuit inlet 1" Gas M
Volume De H A H1 H2 H3 H4 H6 H7 H8
AND SPARE PARTS
Model
ACCESORIES
[litres]
300 291 650 1680 1800 71 243 311 381 832 871 931
500 497 750 1970 2110 71 266 341 406 1031 1071 1139
3-6
H9 H10 H11 H12 H13 H14 1 5 8
Model 9 - 12
TECHNICAL
SUPPORT
Connections Gas F
300 981 1076 1101 1221 1221 1522 1"1/4 Øi 120 1"1/2 1"
500 1181 1291 1326 1471 1471 1812 1"1/4 Øi 120 1"1/2 1"
151
BOLLY® XL
POLYWARM® COATED CALORIFIERS WITH 1 FIXED HEAT EXCHANGER
APPLICATION DRAIN
Production and storage of domestic hot water. External confluence through drain connection.
MATERIAL GASKET- FLANGE PLATE
Mild steel Polywarm® coated (Attestation ACS - SSICA - DVGW - W270 Silicone gaskets suitable for alimentary use for max temperature up
- UBA - WRAS) to 200°C. Mild steel inspection flange plate with Polywarm® treatment
HEAT EXCHANGER and connection for electrical immersion heater.
Polywarm® coated fixed heat exchanger. WARRANTY
INSULATION 5 years - See general sales conditions and warranty
High thermal insulation with ecological polyurethane hard foam. ACCESSORIES AND SPARE PARTS : See Accessories section for
Grey PVC external lining the entire list.
CATHODE PROTECTION
Magnesium anode.
POLYWARM®
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
ENERGY
HEAT EXCHANGER EFFICIENCY
BOLLY® XL WB SURFACE CLASS
HARD FOAM
Model insulation [m2] ErP
Art. Nr.
200 3105162320702 2 B
300 3105162320703 3,4 C
400 3105162320706 4,4 C
500 3105162320705 5,4 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Accessories on request
“Easy Control” Electronic Display Thermometer Titanium electronic anode
ART. NR. Art. Nr.
5032240000107 Art. Nr. Model
5005000310003
5 units box 5200000000008 200, 300,400
5200000000009 500
152
BOLLY® XL
EXTRA- BOLLY®
CALORIFIERS
POLYWARM® COATED CALORIFIERS WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
STAINLESS STEEL
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(10) (11)
CALORIFIERS FOR
HEAT PUMP
H11 (9) H10 (8)
H9 (7)
1 Drain 1"1/4 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2 Domestic cold water circuit inlet
HYDRONIC
H4 (4) (5) (6) 6 Connection for electrical immersion 1"1/2 Gas F
H3 (3)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H2 (2) 7 Recirculation
INERTIAL
TANKS
10 Connection for magnesium anode 1"1/4 Gas F
WATER PRESSURE
TANKS
(4) (8)
Volume De H A H1 H2
Model
COMPRESSED AIR
[litres] [mm]
RECEIVERS
153
TERMOMAS® 1 PDC
HEATING WATER BUFFER TANK FOR HEAT PUMP WITH MACS® MODULE
FOR IMMEDIATE DHW PRODUCTION
APPLICATION D.H.W. HEAT EXCHANGER
Heating water storage and immediate Domestic Hot Water (DHW) Plate to plate stainless steel exchanger in external MACS® module for
production at high flow rate and performance. Primary storage immediate D.H.W. production.
temperatures can be rather low. INSULATION
TECHNICAL DESCRIPTION Buffer tank: High thermal insulation with ecological polyurethane hard
Expressly designed to be connected to heat pump, Termomas PDC foam.
models have the following advantages: MACS® Module: insulating PPE cover.
- easy maintenance Grey PVC external lining
- maximum hygiene for anti-legionellosis bacteria WARRANTY
- more DHW production at low primary storage temperatures 5 years (tank)
- heating water storage optimization. See general sales conditions and warranty for electrical parts.
MATERIAL ACCESSORIES AND SPARE PARTS
Mild steel outside painted. There is no need of any anti-corrosion See Accessories section for the entire list.
treatment due to the fact that the buffer is in a closed circuit without
any adding air.
ENERGY
TERMOMAS® 1 PDC VB EFFICIENCY
HARD FOAM INSULATION
CLASS
HARD FOAM Heat pump max
Model insulation output SLB heat exchanger ErP
model / plates nr.
Art. Nr. [kW]
300 3251162284262 26 SLB40 / 40 C
500 3251162284263 26 SLB40 / 40 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Model insulation output
model / plates nr.
Art. Nr. [kW]
800 3251162284265 35 SLB40 / 40 C
PATENTED
Accessories on request
Thermometer Recirculation kit
Art. Nr. Art. Nr.
5032240000107 5221000000054
5 units box Control display + pump
(for D.H.W.)
154
TERMOMAS® 1 PDC
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK FOR HEAT PUMP WITH MACS® MODULE
FOR IMMEDIATE DHW PRODUCTION
BOLLYTERM®
Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
STAINLESS STEEL
Cordivari LAB are certified conforming
CALORIFIERS
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES 1-3 Heating return / To Generator 1"1/2 Gas F
DATA RESULTS
2-4-5-8 Connection for instrumentation 1/2" Gas F
De
Df 6 Electrical immersion 1"1/2 Gas F
(10) 7-9 Heating return Heating delivery 1"1/2 Gas F
CALORIFIERS FOR
HEAT PUMP
10 Heating delivery 1"1/2 Gas F
(15)(16) 15 Domestic hot water inlet 1” GAS M
H9 (7) (8) (9) 16 Domestic hot water outlet (ACS) 1” GAS M
H5 (6)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H7 (5)
H
(10)
(1) (7) (3) (9)
A
H3 (4)
(2)(4)(5)
HYDRONIC
(6)(8)
H1 (1) (2) (3)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
(16)
0
(15)
INERTIAL
TANKS
WATER PRESSURE
Volume Weight De H A H1 H3 H5 H7 H9
Model
TANKS
[litres] [Kg] [mm]
300 286 106 650 1310 1344 232 425 855 625 1048
500 478 126 650 1619 1666 247 583 1124 841 1343
800 803 152 950 1838 1885 265 613 1338 1038 1541
COMPRESSED AIR
RECEIVERS
HEAT PUMP
COMPRESSOR
EVAPORATOR CONDENSATOR
TECHNICAL
Heat Transferred
Heat Transferred
SUPPORT
ĨƌŽŵĐŽůĚŇƵŝĚ
ƚŽŚŽƚŇƵŝĚ
Expansion
valve
155
TERMOMAS® 3 PDC
HEATING WATER BUFFER TANK FOR HEAT PUMP WITH MACS® MODULE
FOR IMMEDIATE DHW PRODUCTION AND 2 FIXED HEAT EXCHANGERS
APPLICATION HEATING WATER HEAT EXCHANGER
Heating water storage and immediate Domestic Hot Water (DHW) The buffer tank is equipped with 2 mild steel fixed heat exchangers
production at high flow rate and performance. Primary storage to integrate other energy sources such as solar system or traditional
temperatures can be rather low. boiler, in addition to heat pump.
TECHNICAL DESCRIPTION INSULATION
Expressly designed to be connected to heat pump, Termomas PDC Buffer tank: High thermal insulation with ecological polyurethane hard
models have the following advantages: foam.
- easy maintenance MACS® Module: insulating PPE cover.
- maximum hygiene for anti-legionellosis bacteria Grey PVC external lining
- more DHW production at low primary storage temperatures WARRANTY
- heating water storage optimization. 5 years (tank)
MATERIAL See general sales conditions and warranty for electrical parts.
Mild steel outside painted. There is no need of any anti-corrosion ACCESSORIES AND SPARE PARTS
treatment due to the fact that the buffer is in a closed circuit without See Accessories section for the entire list.
any adding air.
D.H.W. HEAT EXCHANGER
Plate to plate stainless steel exchanger in external MACS® module for
immediate D.H.W. production.
ENERGY
TERMOMAS® 3 PDC Heat pump
HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Model insulation max output ErP
model / plates nr.
Art. Nr. [kW] [m2]
800 3251162284365 35 1,8 2,5 SLB40 / 40 C
PATENTED
Accessories on request
Thermometer Recirculation kit
Art. Nr. Art. Nr.
5032240000107 5221000000054
5 units box Control display + pump
(for D.H.W.)
156
TERMOMAS® 3 PDC
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK FOR HEAT PUMP WITH MACS® MODULE
FOR IMMEDIATE DHW PRODUCTION AND 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
STAINLESS STEEL
Cordivari LAB are certified conforming
CALORIFIERS
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES 1-3 Heating return / To Generator 1"1/2 Gas F
DATA RESULTS
2-4-5-8 Connection for instrumentation 1/2" Gas F
6 Electrical immersion 1"1/2 Gas F
De 7-9 Heating return Heating delivery 1"1/2 Gas F
CALORIFIERS FOR
Df
HEAT PUMP
(10) 10 Heating delivery 1"1/2 Gas F
15 Domestic hot water inlet 1” GAS M
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H8 (14)
H7 (6)
H6 (13)
A
H5 (5) (10)
H4 (12) (1) (7) (3) (8)
HYDRONIC
H3 (4) (2)(4)(5)(13)
(6)(14)(9) (11) (12)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
WATER PRESSURE
Volume Weight Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10
Model
TANKS
[litres] [Kg]
300 278 106 550 650 1310 1344 232 195 425 604 645 762 870 1002 1048 1085
500 456 162 650 750 1669 1666 247 260 583 854 904 1010 1124 1301 1393 1430
800 775 205 790 950 1836 1885 265 265 613 749 898 1020 1138 1346,5 1541 1578
COMPRESSED AIR
RECEIVERS
HEAT PUMP
COMPRESSOR
EVAPORATOR CONDENSATOR
TECHNICAL
Heat Transferred
Heat Transferred
SUPPORT
ĨƌŽŵĐŽůĚŇƵŝĚ
ƚŽŚŽƚŇƵŝĚ
Expansion
valve
157
TERMOMAS® PDC - OUTPUT AND PERFORMANCES
PERFORMANCES DURING DHW PRODUCTION PHASE
P = 0 kW P = 5 kW P = 10 kW P = 15 kW P = 20 kW P = 25 kW
Model
Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l]
DHW 10°C/45°C 10 334 10 420 10 565 10 865 10 1845 10 continuous
Storage initial T 20 334 20 372 20 420 20 482 20 565 20 684
55°C 26,3 334 26,3 362 26,3 395 26,3 435 26,3 485 26,3 547
300
DHW 10°C/45°C 10 264 10 331 10 447 10 684 10 684 10 continuous
Storage initial T 20 264 20 294 20 331 20 381 20 381 20 540
50°C 21 264 21 292 21 327 21 373 21 373 21 515
P = 0 kW P = 15 kW P = 20 kW P = 25 kW P = 30 kW P = 35 kW
Model
Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l]
DHW 10°C/45°C 10 557 10 1444 10 3078 10 continuous 10 continuous 10 continuous
Storage initial T 20 557 20 803 20 943 20 1141 20 1444 20 1966
55°C 26,3 557 26,3 726 26,3 808 26,3 912 26,3 1045 26,3 1224
500
DHW 10°C/45°C 10 441 10 1143 10 2437 10 continuous 10 continuous 10 continuous
Storage initial T 20 441 20 636 20 746 20 903 20 1143 20 1556
50°C 21 441 21 623 21 722 21 860 21 1062 21 1389
P = 0 kW P = 15 kW P = 20 kW P = 25 kW P = 30 kW P = 35 kW
Model
Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l]
DHW 10°C/45°C 10 891 10 2310 10 4923 10 continuous 10 continuous 10 continuous
Storage initial T 20 891 20 1285 20 1508 20 1825 20 2310 20 3144
55°C 26,3 891 26,3 1162 26,3 1293 26,3 1458 26,3 1672 26,3 1958
800
DHW 10°C/45°C 10 705 10 1827 10 3896 10 continuous 10 continuous 10 continuous
Storage initial T 20 705 20 1017 20 1193 20 1444 20 1827 20 2488
50°C 21 705 21 996 21 1155 21 1375 21 1698 21 2220
DHW collection data are meant for use with one heat pump connected to the storage, without considering possible contribution of other energy sources.
Exchangeable thermal powers are expressed both in kW and Kcal/h according to the average temperature difference between primary and secondary, having a
primary flow rate of 3 m²/h.
60
50000
50
120 40
100000
Output [KCal/h]
Output [KCal/h]
800 30000
Output [kW]
Output [kW]
100
80000
30
80
500-600
60000 20000
60 20
800 LT
40000
40
500 LT
10000
10
20000
20
0 0
0 5 10 15 20 25 30 35 0 0
0 5 10 15 20 25 30 35
Average Delta[°C]
Delta T medio [°C]
Average Delta[°C]
158
TERMOMAS® PDC - OUTPUT AND PERFORMANCES
EXTRA- BOLLY®
CALORIFIERS
TERMOMAS 3 PDC HEAT EXCHANGER PRESSURE LOSS
BOLLYTERM®
CALORIFIERS
LOWER HEAT EXCHANGER PRESSURE LOSS
STAINLESS STEEL
CALORIFIERS
0 20 40 60 80 100 120 140
900
9000
800 8000
700 7000
CALORIFIERS FOR
600 6000
HEAT PUMP
[mm H 2 O]
500 5000
[mbar]
800
400 4000
500
300 3000
CYLINDERS - PUFFER
MULTIFUEL ENERGY
LOWER heat exchanger 200 2000
surface [m2]
100 1000
300 1,2
500 3 0 0
800 2,5 0 1 2 3 4 5 6 7 8 9
Flow Rate [m3/h]
HYDRONIC
INERTIAL
TANKS
UPPER HEAT EXCHANGER PRESSURE LOSS
WATER PRESSURE
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80 90 100
TANKS
600
6000
500 5000
COMPRESSED AIR
RECEIVERS
400 4000
[mm H 2 O]
[mbar]
800
300 3000
500
AND SPARE PARTS
200 2000
ACCESORIES
159
ECO COMBI 1 PDC
MULTI-HEAT ENERGY BUFFER FOR HEAT PUMP
WITH 316L STAINLESS STEEL DHW CORRUGATED PIPE
APPLICATION • In this system, the high potentiality of the Eco Combi allows to
Heating hot water storage and D.H.W. production. obtain a good DHW production, even if temperatures of the primary
MATERIAL system are not so high (e.g. using heating pumps as primary source
• BUFFER TANK: made in mild steel outside painted. There is no need and solar source as support).
of any anti-corrosion treatment due to the fact that the buffer is in a The particular shape of the corrugated pipe is avoiding any problem
closed circuit without any adding air. relating to the DHW storage and ensure high heating exchange
• DHW STORAGE: 316L stainless steel corrugated pipe, suitable performances.
drinkable water according to D.M. n. 174 dated 06.04.04. INSULATION
TECHNICAL DESCRIPTION High thermal insulation with ecological polyurethane hard foam.
Multi-heat Energy tanks EcoCombi 1 are used in units with a typically Grey PVC external lining
discontinuous energy source for double use: heating system and WARRANTY
domestic hot water. 5 years - See general sales conditions and warranty
• Heating system with a biomass generator as energy source, ACCESSORIES AND SPARE PARTS
combining the possibility to produce domestic hot water. In such See Accessories section for the entire list.
case, storage heating volume allows the generator to regularly work,
limiting number of stops due to the inadequate energy request of
the heating system. Moreover, it limits the emission of smoke and
creation of corrosive condensate (smokes side).
CLASS
HARD FOAM max output
Volume Surface ErP
Model insulation
Art. Nr. [kW] [lt] [m2]
300 3270162310002 26 26,6 4,5 C
500 3270162310003 26 31 5,3 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
DISMOUNTABLE HARD FOAM Volume Surface ErP
Model insulation
Art. Nr. [kW] [lt] [m2]
800 3270162310005 35 45 7,7 C
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Buffer tanks connecting kit Kit Recirculation
Art. Nr. Art. Nr. Connection Art. Nr.
5032240000107 5006170001001 1” 1/2 5221000000019
5 units box Stainless steel extensible Attacco 3/4”
connecting kit - (200 ÷ 400 mm)
160
ECO COMBI 1 PDC
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER FOR HEAT PUMP
WITH 316L STAINLESS STEEL DHW CORRUGATED PIPE
CORRUGATED DHW
STORAGE
STAINLESS STEEL PIPE
BOLLYTERM®
Pmax Tmax Pmax
CALORIFIERS
3 bar 99 °C 6 bar
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
STAINLESS STEEL
Cordivari LAB are certified conforming
CALORIFIERS
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
1 Drain 1"1/4 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
6-7 Connection for instrumentation 1/2" Gas F
HYDRONIC
H10 (11) 16 Domestic hot water outlet
H8 (9)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H6 (7)
INERTIAL
TANKS
(1)(17)
(3)(13) (4)(14)
H5 (6)
H3 (3)(4) H2 (2)
WATER PRESSURE
(5)(8)(10)(12) (2)(9)(16)
H1 (1)
TANKS
0 (6)(7)(11)(15)
COMPRESSED AIR
RECEIVERS
Volume De H A H1 H2 H3
Model
[litres] [mm]
AND SPARE PARTS
161
ECO COMBI 3 PDC
MULTI-HEAT ENERGY BUFFER FOR HEAT PUMP
WITH 316L STAINLESS STEEL DHW CORRUGATED PIPE AND 2 FIXED HEAT EXCHANGERS
APPLICATION limiting number of stops due to the inadequate energy request of
Heating hot water storage and D.H.W. production. the heating system. Moreover, it limits the emission of smoke and
MATERIAL creation of corrosive condensate (smokes side).
• BUFFER TANK: made in mild steel outside painted. There is no need • In this system, the high potentiality of the Eco Combi allows to
of any anti-corrosion treatment due to the fact that the buffer is in a obtain a good DHW production, even if temperatures of the primary
closed circuit without any adding air. system are not so high (e.g. using heating pumps as primary source
• DHW STORAGE: 316L stainless steel corrugated pipe, suitable and solar source as support).
drinkable water according to D.M. n. 174 dated 06.04.04. The particular shape of the corrugated pipe is avoiding any problem
HEAT EXCHANGERS: relating to the DHW storage (less, stagnation, bacterium, etc.) and
2 fixed heat exchangers. ensure high heating exchange performances.
TECHNICAL DESCRIPTION INSULATION
Multi-heat Energy tanks EcoCombi 3 are used in units with a typically High thermal insulation with ecological polyurethane hard foam.
discontinuous energy source for double use: heating system and Grey PVC external lining
domestic hot water. WARRANTY
• Heating system with a biomass generator as energy source, 5 years - See general sales conditions and warranty
combining the possibility to produce domestic hot water. In such ACCESSORIES AND SPARE PARTS
case, storage heating volume allows the generator to regularly work, See Accessories section for the entire list.
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
DISMOUNTABLE HARD FOAM
insulation Volume Surface Volume Surface Volume Surface ErP
Model
Art. Nr. [kW] [lt] [m2] [lt] [m2] [lt] [m2]
800 3270162310205 35 45 7,7 11,3 1,7 16,9 2,6 C
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
connecting kit - (200 ÷ 400 mm)
162
ECO COMBI 3 PDC
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER FOR HEAT PUMP
WITH 316L STAINLESS STEEL DHW CORRUGATED PIPE AND 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
Pmax Tmax Pmax Pmax Tmax
CALORIFIERS
3 bar 99 °C 6 bar 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
STAINLESS STEEL
Cordivari LAB are certified conforming
CALORIFIERS
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
3-4 Heating return - to generator 1"1/2 Gas F
HEAT PUMP
5 Lower fixed heat exchanger outlet 1" Gas F
De 6-7 Connection for instrumentation 1/2" Gas F
Df 8 Lower fixed heat exchanger inlet 1" Gas F
(17)
9 Electrical immersion 1"1/2 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
10 Upper fixed heat exchanger outlet 1" Gas F
11 Connection for instrumentation 1/2" Gas F
H12 (13)(14) H13 (15)(16)
12 Upper fixed heat exchanger inlet 1" Gas F
H11 (12)
13-14-17 Heating return - Heating delivery 1"1/2 Gas F
A
HYDRONIC
H9 (10)
H8 (9)
H7 (8)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H6 (7)
INERTIAL
(1)(17)
TANKS
(3)(13) (4)(14)
H5 (6)
H4 (5)
H3 (3)(4) H2 (2)
(5)(8)(10)(12) (2)(9)(16)
WATER PRESSURE
H1 (1)
0 (6)(7)(11)(15)
TANKS
COMPRESSED AIR
RECEIVERS
Volume De H A H1 H2 H3 H4 H5
Model
[lt]
300 291 650 1585 1713 70 297 330 330 390
AND SPARE PARTS
ACCESORIES
300 745 870 970 1040 1100 1280 1280 1315 1/2" F
500 760 930 990 1075 1115 1376 1468 1485 1" M
800 780 905 935 1065 1135 1409 1618 1635 1" M
163
ECO COMBI PDC - OUTPUT AND PERFORMANCES
PERFORMANCES DURING DHW PRODUCTION PHASE
P = 0 kW P = 5 kW P = 10 kW P = 15 kW
Model
Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l]
DHW 10°C/45°C 10 118 10 142 10 166 10 190
Storage initial T 20 82 20 91 20 99 20 107
55°C 30 47 30 50 30 54 30 57
300
DHW 10°C/45°C 10 96 10 115 10 135 10 154
Storage initial T 20 67 20 73 20 80 20 87
50°C 30 39 30 41 30 44 30 46
P = 0 kW P = 5 kW P = 10 kW P = 15 kW P = 20 kW P = 25 kW
Model
Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l]
DHW 10°C/45°C 10 293 10 353 10 413 10 473 10 533 10 593
Storage initial T 20 223 20 246 20 269 20 291 20 314 20 337
55°C 30 153 30 163 30 174 30 184 30 195 30 205
500
DHW 10°C/45°C 10 240 10 289 10 338 10 387 10 436 10 485
Storage initial T 20 182 20 201 20 220 20 238 20 257 20 276
50°C 30 125 30 134 30 142 30 151 30 159 30 168
P = 0 kW P = 15 kW P = 20 kW P = 25 kW P = 30 kW P = 35 kW
Model
Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l] Q [l/min] V [l]
DHW 10°C/45°C 10 469 10 757 10 853 10 949 10 1045 10 1141
Storage initial T 20 367 20 480 20 517 20 555 20 592 20 630
55°C 30 266 30 320 30 339 30 357 30 375 30 393
800
DHW 10°C/45°C 10 384 10 619 10 698 10 777 10 855 10 934
Storage initial T 20 300 20 392 20 423 20 454 20 485 20 515
50°C 30 218 30 262 30 277 30 292 30 307 30 322
DHW collection data are meant for use with one heat pump connected to the storage, without considering possible contribution of other energy sources.
60
50000
50
140 120000 40000
120 40
100000
800
Output [KCal/h]
30000
Output [KCal/h]
Output [kW]
100
Output [kW]
80000 30
80 500
60000 20000
60 20
800 40000
40
10000
500 10
20 20000
0 0 0 0
0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35
Average Delta[°C]
Average Delta[°C]
164
ECO COMBI PDC - OUTPUT AND PERFORMANCES
EXTRA- BOLLY®
CALORIFIERS
PERFORMANCES DURING DHW PRODUCTION PHASE
BOLLYTERM®
CALORIFIERS
ECO COMBI 2 PDC - ECO COMBI 3 PDC UPPER HEAT EXCHANGER PRESSURE LOSS
STAINLESS STEEL
CALORIFIERS
0 20 40 60 80 100 120 140
900
9000
800 8000
700 7000
CALORIFIERS FOR
600 6000
HEAT PUMP
[mm H 2 O]
500 5000
[mbar]
800
400 4000
500
300 3000
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Upper 200 2000
Heat exchanger surface
100 1000
300 0,7
500 1,2 0 0
800 1,7 0 1 2 3 4 5 6 7 8 9
Flow Rate [m3/h]
HYDRONIC
INERTIAL
TANKS
ECO COMBI 2 PDC - ECO COMBI 3 PDC LOWER HEAT EXCHANGER PRESSURE LOSS
WATER PRESSURE
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80 90 100
TANKS
600
6000
500 5000
COMPRESSED AIR
RECEIVERS
400 4000
[mm H 2 O]
[mbar]
800
300 3000
500
AND SPARE PARTS
200 2000
ACCESORIES
165
MULTIFUEL ENERGY
CILINDERS
AND BUFFER TANKS
166
167
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
PUFFER
HEATING WATER BUFFER TANK
APPLICATION INSULATION
Efficient storage of heating hot water mostly using biomass, heat - HARD: High thermal insulation with ecological polyurethane hard foam.
pumps or solar thermal energy sources. - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
MATERIAL with high thermal insulation. Fire resistance class B-s2d0 according
Mild steel outside painted. There is no need of any anti-corrosion to EN 13501.
treatment due to the fact that the buffer is in a closed circuit without Grey PVC external lining complete with top and flange cover
any adding air. WARRANTY
TECHNICAL DESCRIPTION 5 years - See general sales conditions and warranty
Used to improve flexibility of pellets, stoves and burners. PUFFER are ACCESSORIES AND SPARE PARTS
used in units with a typically discontinuous energy source such as See Accessories section for the entire list.
biomass boiler and solar thermal system.
S T O C K
grey
AVAILABILITY
ENERGY
PUFFER VB EFFICIENCY
CLASS
HARD FOAM
Model insulation ErP
Art. Nr.
HARD FOAM INSULATION
200 3251162312501 B
300 3251162312502 C
500 3251162312503 C
600 3251162312504 C
750 3251162312525 C
800 3251162312526 C
1000 3251162312527 C
1250 3251162312508 C
1500 3251162312509 C
2000 3251162312510 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
DISMOUNTABLE HARD FOAM
Model insulation ErP
Art. Nr.
750 3251162312505 C
800 3251162312506 C
1000 3251162312507 C
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
PUFFER VC EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE
Model insulation ErP
Art. Nr.
750 3251162282804 C
800 3251162282805 C
1000 3251162282806 C
1500 3251162282807 C
2000 3251162282808 C
3000 3251162282608
5000 3251162282610
Accessories on request
Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
connecting kit - (200 ÷ 400 mm)
168
PUFFER
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK
STORAGE
Pmax Tmax
3 bar 99 °C
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
1-3-6-7 Heating return/To Generator
CALORIFIERS
DATA RESULTS
CALORIFIERS FOR
11-12-
H12 (14) (15) (16) Heating delivery/ Heating return
HEAT PUMP
14-16
13 Connection for instrumentation 1/2" Gas F
H11 (13) 15 Connection for instrumentation 1/2" Gas F
17 Heating delivery
H9 (11) (12) 20 Drain only for models 3000 e 5000
H8
CYLINDERS - PUFFER
MULTIFUEL ENERGY
(10)
H
A
H7 (9)
H5 (6) (7)
(17)
H4 (5)
HYDRONIC
(20)
0 (2) (5) (9)
(10) (13) (15)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
Volume Df De De H A H2 H4
Model (vers. VC) (vers. VC) (vers. VB)
[lt] [mm] [mm]
WATER PRESSURE
200 180 // // 550 1299 1410 218 430
300 279 // // 650 1340 1489 232 444
TANKS
500 478 // // 750 1620 1784 247 533
600 560 // // 750 1870 2014 247 582
750 717 790 1010 950 1658 1911 265 584
800 805 790 1010 950 1840 2071 265 584
1000 946 790 1010 950 2130 2332 265 656
1250 1248 // // 1050 2201 2439 313 705
COMPRESSED AIR
1-3-6-7-9
H5 H7 H8 H9 H11 H12 20
AND SPARE PARTS
169
PUFFER COMPACT
HEATING WATER BUFFER TANK
APPLICATION INSULATION
Efficient storage of heating hot water mostly using biomass, heat NOFIRE® polyester fleece 100% made of recyclable material, with
pumps or solar thermal energy sources. high thermal insulation. Fire resistance class B-s2d0 according to EN
MATERIAL 13501.
Mild steel outside painted. There is no need of any anti-corrosion Grey PVC external lining complete with top and flange cover
treatment due to the fact that the buffer is in a closed circuit without WARRANTY
any adding air. 5 years - See general sales conditions and warranty
TECHNICAL DESCRIPTION ACCESSORIES AND SPARE PARTS
Used to improve flexibility of pellets, stoves and burners. PUFFER See Accessories section for the entire list.
COMPACT are used in units with a typically discontinuous energy
source such as biomass boiler and solar thermal system.
Suitable for low-ceilinged rooms.
S T O C K
grey
AVAILABILITY
PUFFER COMPACT VC
SOFT FLEECE INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Accessories on request
Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
connecting kit - (200 ÷ 400 mm)
170
PUFFER COMPACT
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK
STORAGE
Pmax Tmax SUITABLE FOR
3 bar 99 °C LOW-CEILINGED ROOMS
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
CALORIFIERS
DATA RESULTS
De
Df
CALORIFIERS FOR
(17)
HEAT PUMP
1-3-6-7 Heating return/To Generator
2-5 Connection for instrumentation 1/2" Gas F
H12 (14)
(15) (16) 9 Electrical immersion
H11 (13) 10 Connection for instrumentation 1/2" Gas F
A
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H9 (11) (12) 11-12-
H8 (10) Heating delivery/ Heating return
14-16
H7 (9)
H
HYDRONIC
0
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
H1 (20)
0
WATER PRESSURE
(1) (6) (3) (7)
(11) (14) (12) (16)
TANKS
(2) (5) (9)
(10) (13) (15)
100°
COMPRESSED AIR
RECEIVERS
Volume Df De H A H1 H2 H4 H5
Model
[lt] [mm]
2500 2306 1250 1450 2351 2455 140 556 886 996
3000 3017 1500 1700 2180 2374 109,5 567 841 932
4000 3986 1600 1800 2456 2643 94,5 574 910 1022
4500 4411 1800 2000 2230 2575 90 582 856 947
AND SPARE PARTS
171
PUFFER - FLANGED CONNECTIONS
HEATING WATER BUFFER TANKS WITH 90° AND 180° FLANGED CONNECTIONS
APPLICATION INSULATION
Efficient storage of heating hot water mostly using biomass, heat NOFIRE® polyester fleece 100% made of recyclable material, with
pumps or solar thermal energy sources. high thermal insulation. Fire resistance class B-s2d0 according to EN
MATERIAL 13501.
Mild steel outside painted. There is no need of any anti-corrosion Grey PVC external lining complete with top and flange cover
treatment due to the fact that the buffer is in a closed circuit without WARRANTY
any adding air. 5 years - See general sales conditions and warranty
TECHNICAL DESCRIPTION ACCESSORIES AND SPARE PARTS
Used to improve flexibility of pellets, stoves and burners. PUFFER See Accessories section for the entire list.
FLANGED are used in units with a typically discontinuous energy
source such as biomass boiler and solar thermal system.
PUFFER FLANGED have been conceived for medium/large biomass
heating plants where flanged connections are required.
PUFFER FLANGED have reduced height for maximum flexibility of
installation
180°
Model insulation
Art. Nr.
2500 3251162282680
3000 3251162282681
4000 3251162282682
4500 3251162282683
5000 3251162282684
6000 3251162282685
8000 3251162282686
10000 3251162282620
12000 3251162282621
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
PUFFER FLANGIATI VC (90°)
DISMOUNTABLE SOFT FLEECE
SOFT FLEECE INSULATION
Model insulation
Art. Nr.
2500 3251162282690
3000 3251162282691
90° 4000 3251162282692
4500 3251162282693
5000 3251162282694
6000 3251162282695
8000 3251162282696
10000 3251162282622
12000 3251162282623
Accessories on request
Thermometer
Art. Nr.
5032240000107
5 units box
172
PUFFER - FLANGED CONNECTIONS
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANKS WITH 90° AND 180° FLANGED CONNECTIONS
STORAGE
Pmax Tmax
3 bar 99 °C
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
CALORIFIERS
DATA RESULTS
CALORIFIERS FOR
1 Drain 1” Gas F (for models 10000 e 12000 2” Gas F)
HEAT PUMP
2-4 To generator / Heating return
6-8 Heating delivery / Heating return
3-5-7 Connection for instrumentation 1/2” Gas F
9 Heating delivery
CYLINDERS - PUFFER
MULTIFUEL ENERGY
180° FLANGED 90° FLANGED
CONNECTIONS CONNECTIONS
De De
Df Df
(9) (9)
HYDRONIC
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H4 (6)(7)(8) H4 (6)(7)(8)
H5 (10)
A
A
H3 (5) H3 (5)
INERTIAL
TANKS
H
H
H2 (2)(3)(4) H2 (2)(3)(4)
WATER PRESSURE
H1 (1) H1 (1)
Standard supporting feet
TANKS
0 0
for models 10000 and
12000
COMPRESSED AIR
RECEIVERS
45
90
90
45
AND SPARE PARTS
ACCESORIES
Volume Df De H A H1 H2 H3 H4 H5 2-4-6-8 9
Model
[litres] [mm] Connections Gas F
2500 2306 1250 1450 2351 2433 140 616 1216 1816 // PN16 DN80 1"1/2
3000 3017 1500 1700 2180 2305 109 640 1115 1590 // PN16 DN80 2"
4000 3986 1600 1800 2456 2583 95 646 1246 1846 // PN16 DN80 2"
4500 4411 1800 2000 2230 2405 89 655 1130 1605 // PN16 DN80 2"
TECHNICAL
SUPPORT
5000 5042 1800 2000 2480 2638 89 675 1255 1835 // PN16 DN100 2"
6000 5672 1800 2000 2730 2875 89 675 1380 2085 // PN16 DN100 2"
8000 7564 1800 2000 3480 3594 89 675 1705 2835 // PN16 DN100 2”
10000 10455 2000 2200 3916 4007 191 826 1636 3256 2446 PN16 DN100 2”
12000 12010 2000 2200 4461 4502 191 826 1803 3756 2779 PN16 DN100 2”
173
PUFFER 1
HEATING WATER BUFFER TANK WITH 1 FIXED HEAT EXCHANGER
APPLICATION INSULATION
Efficient storage of heating hot water mostly using biomass, heat - HARD: High thermal insulation with ecological polyurethane hard foam.
pumps or solar thermal energy sources. - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
MATERIAL with high thermal insulation. Fire resistance class B-s2d0 according
Mild steel outside painted. There is no need of any anti-corrosion to EN 13501.
treatment due to the fact that the buffer is in a closed circuit without Grey PVC external lining complete with top and flange cover
any adding air. WARRANTY
HEAT EXCHANGER 5 years - See general sales conditions and warranty
1 mild steel fixed heat exchanger ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Used to improve flexibility of pellets, stoves and burners. PUFFER 1
are used in units with a typically discontinuous energy source such as
biomass boiler and solar thermal system.
PUFFER 1 allows the solar energy system integration.
S T O C K
grey
AVAILABILITY
ENERGY
PUFFER 1 VB EFFICIENCY
CLASS
HEAT EXCHANGER
SURFACE
HARD FOAM
insulation ErP
HARD FOAM INSULATION
Model
Art. Nr. [m2]
300 3251162312201 1,0 C
500 3251162312202 1,9 C
600 3251162312203 2,1 C
750 3251162312214 2,3 C
800 3251162312215 2,5 C
1000 3251162312216 3,1 C
1250 3251162312207 3,4 C
1500 3251162312208 3,8 C
2000 3251162312209 4,6 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Art. Nr. [m2]
750 3251162312204 2,3 C
800 3251162312205 2,5 C
1000 3251162312206 3,1 C
www.cordivari.com/erp
On line ErP label tool
ENERGY
PUFFER 1 VC EFFICIENCY
SOFT FLEECE INSULATION
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 12 400 - TRIPHASE
See accessories
174
PUFFER 1
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH 1 FIXED HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
CALORIFIERS
DATA RESULTS
De
1-3-6-7 Heating return/To Generator
Df
(17) Connection for instrumentation 1/2"
CALORIFIERS FOR
(20) 2-5
Gas F
HEAT PUMP
4 Lower fixed heat exchanger outlet
H12 (14) (15) (16) Only for models 3000 e 5000
8 Lower fixed heat exchanger inlet
H11 (13)
9 Electrical immersion
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H9 (11) (12) Connection for instrumentation 1/2"
H8 10
Gas F
H
(10) 11-12-
A
HYDRONIC
(2) (5) (9) (4) (8) 17 Heating delivery
H2 (1) (2) (3) H3 (4)
(10) (13) (15)
20 Drain only for models 3000 e 5000
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
100°
0
INERTIAL
TANKS
Volume Df De De H A H2 H3 H4
Model (vers. VC) (vers. VC) (vers. VB)
[lt] [mm] [mm]
WATER PRESSURE
300 279 // // 650 1340 1489 232 217 444
500 478 // // 750 1620 1784 247 260 533
TANKS
600 560 // // 750 1870 2014 247 260 582
750 717 790 1010 950 1658 1911 265 278 584
800 805 790 1010 950 1840 2071 265 278 584
1000 946 790 1010 950 2130 2332 265 284 656
1250 1248 // // 1100 2201 2439 313 326 705
1500 1454 950 1210 1100 2250 2504 313 336 736
COMPRESSED AIR
2000 1973 1100 1360 1300 2320 2659 347 370 770
RECEIVERS
1-3-6-7-9-11-
H5 H6 H7 H8 H9 H11 H12 4-8 20
AND SPARE PARTS
Model 12-14-16-17
ACCESORIES
1250 835 884 986 1168 1357 1568 1879 1" 1/2 1" //
SUPPORT
1500 845 1006 1061 1286 1377 1653 1909 1" 1/2 1" //
2000 879 1001 1060 1300 1411 1687 1943 1" 1/2 1" //
3000 1071 1551 1693 1879 1786 2140 2402 2" 1"1/4 1"
5000 1101 1522 1691 1889 1816 2159 2432 2" 1"1/4 2"
175
PUFFER 2
HEATING WATER BUFFER TANK WITH 2 FIXED HEAT EXCHANGERS
APPLICATION INSULATION
Efficient storage of heating hot water mostly using biomass, heat - HARD: High thermal insulation with ecological polyurethane hard foam.
pumps or solar thermal energy sources. - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
MATERIAL with high thermal insulation. Fire resistance class B-s2d0 according
Mild steel outside painted. There is no need of any anti-corrosion to EN 13501.
treatment due to the fact that the buffer is in a closed circuit without Grey PVC external lining complete with top and flange cover
any adding air. WARRANTY
HEAT EXCHANGERS 5 years - See general sales conditions and warranty
2 mild steel fixed heat exchangers ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Used to improve flexibility of pellets, stoves and burners. PUFFER 2
are used in units with a typically discontinuous energy source such
as biomass boiler and solar thermal system. PUFFER 2 allows the
solar energy system integration as well as another thermal generator.
ENERGY
PUFFER 2 VB HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Art. Nr. [m2]
750 3251162312705 1,8 2,5 C
800 3251162312706 1,5 2,3 C
1000 3251162312707 2,5 3,1 C
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
PUFFER 2 VC HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE Upper Lower ErP
Model insulation
Art. Nr. [m ]
2
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 9 400 - TRIPHASE
See accessories
176
PUFFER 2
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
CALORIFIERS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
STAINLESS STEEL
CERTIFIED LABORATORIES
CALORIFIERS
DATA RESULTS
CALORIFIERS FOR
Connection for instrumentation 1/2"
2-5
HEAT PUMP
(17)
Gas F
4 Lower fixed heat exchanger outlet
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H10 (19) Connection for instrumentation 1/2"
H11 (13) 10
Gas F
11-12-
Heating delivery/ Heating return
H9 (11) (12) 14-16
Connection for instrumentation 1/2"
H8 (10) 13
Gas F
H
(17)
(18) Connection for instrumentation 1/2"
A
15
H7 (9) Gas F
H6 (8) (1) (6) (3) (7) 17 Heating delivery
HYDRONIC
H5 (6) (7)
(11) (14) (12) (16) Upper fixed heat exchanger outlet
18
H4 (5) 1" Gas F
Upper fixed heat exchanger inlet 1"
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
(4) (8) 19
(2) (5) (9) Gas F
(10) (13) (15) (18)(19)
H2 (1) H3 (4)
(2) (3) 100°
INERTIAL
TANKS
0
H1 (20)
0
Df De De
WATER PRESSURE
Volume (vers. VC) (vers. VC) (vers. VB) H A H2 H3 H4
Model
TANKS
[lt] [mm] [mm]
500 478 // // 750 1620 1784 247 260 533
600 560 // // 750 1870 2014 247 260 582
750 717 790 1010 950 1658 1911 265 278 584
800 805 790 1010 950 1840 2071 265 278 584
1000 946 790 1010 950 2130 2332 265 284 656
COMPRESSED AIR
1500 1435 950 1210 1100 2250 2504 313 336 736
RECEIVERS
2000 1973 1100 1360 1300 2320 2659 347 370 770
AND SPARE PARTS
1-3-6-7-9-11-
H5 H6 H7 H8 H9 H11 H12 4-8 20
ACCESORIES
Model 12-14-16-17
[mm] Connections Gas F
500 629 745 841 930 1011 1231 1343 1" 1/2 1" //
600 695 855 915 1060 1144 1382 1593 1" 1/2 1" //
750 630 679 823 938 995 1180 1371 1" 1/2 1" //
800 690 762 823 988 1115 1332 1541 1" 1/2 1" //
1000 787 953 998 1188 1309 1588 1831 1" 1/2 1" //
TECHNICAL
1500 845 1006 1061 1286 1377 1653 1909 1" 1/2 1" //
SUPPORT
2000 879 1001 1060 1300 1411 1687 1943 1" 1/2 1" //
177
PUFFER 1 FIXED HEAT EXCHANGER POWERS CHART
140 120000
5000 LT
120
100000
3000 LT
100
2000 LT 80000
Output [KCal/h]
Output [kW]
80
1500 LT
60000
60 1000 LT
800 LT
40000
600 LT
40
500 LT
20000
20 300 LT
0 0
0 5 10 15 20 25 30 35
Average Delta[°C]
Thermal output is given in both kW or kcal/h in terms of average temperature difference between primary and secondary circuit, all for a range of primary 3 m3/h.
For example, a PUFFER 1 T of 1000 liters Capacity with a water flow of 3 m3/h at 80 °C inlet and outlet at 70 °C, has on the storage of water an average temperature
of 60 °C, the mean difference of temperature will be:
(80 +70) / 20-60 = 15 °C and therefore you can exchange up to approximately 34 kW.
Output of the lower heat exchangers PUFFER 1 depending on the average DeltaT between primary and accumulation considering flow rate 3 m3/h.
600 3000
6000
1000
[mm H 2 O]
500 5000
[mbar]
800
400 4000
500
300 3000
200 2000
300
100 1000
0 0
0 1 2 3 4 5 6 7 8 9
Flow Rate [m3/h]
178
EXTRA- BOLLY®
CALORIFIERS
PUFFER 2 - UPPER FIXED HEAT EXCHANGER POWERS CHART
For lower exchanger power data see PUFFER 1
60
BOLLYTERM®
50000
CALORIFIERS
1500-2000
50
1000
40000
STAINLESS STEEL
CALORIFIERS
40
Output [KCal/h]
800 30000
Output [kW]
30
CALORIFIERS FOR
500-600
HEAT PUMP
20000
20
10000
CYLINDERS - PUFFER
MULTIFUEL ENERGY
10
0 0
0 5 10 15 20 25 30 35
Average Delta[°C]
HYDRONIC
Output of the lower heat exchangers PUFFER 2 depending on the average DeltaT between primary and accumulation considering flow rate 3 m3/h.
INERTIAL
TANKS
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80 90 100
600
6000
WATER PRESSURE
1500-2000
500
TANKS
5000
1000
[mm H 2 O]
[mbar]
400 4000
COMPRESSED AIR
RECEIVERS
800
300 3000
500- 600
200 2000
AND SPARE PARTS
ACCESORIES
100 1000
0 0
0 1 2 3 4 5 6
TECHNICAL
SUPPORT
179
PUFFER 1 CTS®
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE
AND 1 FIXED HEAT EXCHANGER
APPLICATION in the upper part of the tank the water heated up by the lower fixed
Efficient storage of heating hot water mostly using biomass, heat exchanger. This combination ensures a perfect natural stratification
pumps or solar thermal energy sources. inside the tank with no valve or additional external device.
MATERIAL The lower fixed exchanger allows the possibility of connecting with a
Mild steel outside painted. There is no need of any anti-corrosion solar system. Positioned at the bottom lower part of the buffer tank
treatment due to the fact that the buffer is in a closed circuit without and with very small footprint, it increases the volume available for
any adding air. the storage.
HEAT EXCHANGER INSULATION
1 mild steel fixed heat exchanger with CTS® stratificator system. High thermal insulation with ecological hard polyurethane foam.
TECHNICAL DESCRIPTION Grey PVC external lining
Used to improve flexibility of pellets, stoves and burners. PUFFER 1 WARRANTY
CTS® are used in units with a typically discontinuous energy source 5 years - See general sales conditions and warranty
such as biomass boiler and solar thermal systems. ACCESSORIES AND SPARE PARTS
PUFFER 1 CTS® is characterized by multiple stratification system See Accessories section for the entire list.
based on the combination of Cordivari Labyrinth spreader for
returning heating water with a new stratification device that conveys
ENERGY
HEAT EXCHANGER EFFICIENCY
PUFFER 1 CTS® VB SURFACE CLASS
HARD FOAM INSULATION
HARD FOAM
Model insulation [m2] ErP
Art. Nr.
500 3251162313002 1,9 C
CTS stratificator
® 600 3251162313003 2,1 C
system 800 3251162313014 2,5 C
1000 3251162313015 3,1 C
1500 3251162313006 3,8 C
2000 3251162313007 4,6 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
DISMOUNTABLE HARD FOAM
Model insulation [m2] ErP
Art. Nr.
800 3251162313004 2,5 C
1000 3251162313005 3,1 C
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 9 400 - TRIPHASE
See accessories
180
PUFFER 1 CTS®
EXTRA- BOLLY®
CALORIFIERS
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE
AND 1 FIXED HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
3 bar 99 °C 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
STAINLESS STEEL
indicated by Ecodesign ErP Directive.
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
De
Df
(17)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H12 (14)
(15) (16)
H11 (13)
1-3-7-8 Heating return/To Generator1"1/2 Gas F
HYDRONIC
A
H7 (9)
5 Fixed heat exchanger inlet 1" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H5 (7) (8)
6 Connection for instrumentation 1/2" Gas F
H4 (6)
H6 (5) 9 Electrical immersion 1"1/2 Gas F
INERTIAL
H2 (1)
TANKS
11-12-14-16 Heating delivery/ Heating return 1"1/2 Gas F
(2) (3) H3 (4)
13 Connection for instrumentation 1/2" Gas F
0
15 Connection for instrumentation 1/2" Gas F
WATER PRESSURE
17 Heating delivery / Air purge 1" 1/2 Gas F
TANKS
(17)
50° 50°
RECEIVERS
1000 946 950 2130 2332 265 233 656 787 998 1188 1309 1588 1831
1500 1435 1100 2250 2504 313 281 736 845 1061 1286 1377 1653 1909
2000 1973 1300 2320 2659 347 315 770 879 1060 1300 1411 1687 1943
181
PUFFER 2 CTS®
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE
AND 2 FIXED HEAT EXCHANGERS
APPLICATION the upper part of the tank the water heated up by the lower fixed
Efficient storage of heating hot water mostly using biomass, heat exchanger. This combination ensures a perfect natural stratification
pumps or solar thermal energy sources. inside the tank with no valve or additional external device.
MATERIAL The lower fixed exchanger allows the possibility of connecting with a
Mild steel outside painted. There is no need of any anti-corrosion solar system. Positioned at the bottom lower part of the buffer tank
treatment due to the fact that the buffer is in a closed circuit without and with very small footprint, it increases the volume available for
any adding air. the storage.
HEAT EXCHANGER INSULATION
2 mild steel fixed heat exchangers with CTS® stratificator system. High thermal insulation with ecological hard polyurethane foam.
TECHNICAL DESCRIPTION Grey PVC external lining
Used to improve flexibility of pellets, stoves and burners. PUFFER 2 WARRANTY
CTS® are used in units with a typically discontinuous energy source 5 years - See general sales conditions and warranty
such as biomass boiler and solar thermal systems. ACCESSORIES AND SPARE PARTS
The PUFFER 2 CTS® is characterized by multiple stratification system See Accessories section for the entire list.
based on the combination of Cordivari Labyrinth spreader for returning
heating water with a brand new stratification device that convey in
ENERGY
PUFFER 2 CTS® VB HEAT EXCHANGER SURFACE EFFICIENCY
CLASS
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Model
Art. Nr. [m ]
2
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 9 400 - TRIPHASE
See accessories
182
PUFFER 2 CTS®
EXTRA- BOLLY®
CALORIFIERS
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE
AND 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
CALORIFIERS
3 bar 99 °C 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
to European standard EN 15332, as
STAINLESS STEEL
indicated by Ecodesign ErP Directive.
CALORIFIERS
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
De
Df
(17) 1-3-7-8 Heating return/To Generator1"1/2 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H12 (14) 4 Fixed heat exchanger outlet 1" Gas F
(15) (16)
5 Fixed heat exchanger inlet 1" Gas F
H11 (13) H10 (19)
6 Connection for instrumentation 1/2" Gas F
HYDRONIC
(18)
A
H5 (7) (8)
H4 (6) 15 Connection for instrumentation 1/2" Gas F
INERTIAL
H2 (1) 18 Upper fixed heat exchanger outlet 1" Gas F
TANKS
(2) (3) H3 (4)
19 Upper fixed heat exchanger inlet 1" Gas F
0
WATER PRESSURE
TANKS
(17)
1000 946 950 2130 2332 265 233 656 787 998 1188 1309 1661 1588 1831
1500 1435 1100 2250 2504 313 281 736 845 1061 1286 1377 1673 1653 1909
2000 1973 1300 2320 2659 347 315 770 879 1060 1300 1411 1687 1687 1943
183
MULTIFUEL ENERGY
CYLINDERS
184
185
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
MULTIFUEL ENERGY CYLINDERS RANGE
DHW
production
Heating system
Number of heat
exchangers / / / / /
Energy source
Energy efficiency
C C B-C
class
Suggested Biomass and other energy Biomass and other energy Biomass and other energy
Application source installations source installations source installations
186
EXTRA- BOLLY®
CALORIFIERS
ErP
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
PUFFERMAS® PUFFERMAS® CTS PUFFERMAS® CTS POWER
CYLINDERS - PUFFER
MULTIFUEL ENERGY
- Spiral fixed heat exchanger
- Spiral fixed heat exchanger
- MACS® module for DHW production - MACS® module for DHW production
- MACS® module for DHW production
- Integrated solar station
/ / / / /
HYDRONIC
INERTIAL
TANKS
C C C
WATER PRESSURE
Polyurethane hard foam Polyurethane hard foam Polyurethane hard foam
TANKS
187
COMBI 1
MULTI-HEAT ENERGY BUFFER WITH POLYWARM® COATED TANK IN TANK CALORIFIER FOR D.H.W.
APPLICATION INSULATION
Heating hot water storage and D.H.W. production. - HARD: High thermal insulation with ecological polyurethane hard foam.
MATERIAL - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
Buffer tank: Mild steel construction with exterior paint. No anti- with high thermal insulation. Fire resistance class B-s2d0 according
corrosion treatment required due to the buffer’s closed circuit system. to EN 13501.
D.H.W. storage: Mild steel Polywarm® coated (Attestation ACS - Grey PVC external lining complete with top cover
SSICA - DVGW - W270 - UBA - WRAS) CATHODE PROTECTION
TECHNICAL DESCRIPTION Chain magnesium anode
Multi-Heat Energy tanks Combi1 are used in units with a typically WARRANTY
discontinuous energy source for double use: heating system and 5 years - See general sales conditions and warranty
sanitary hot water system. ACCESSORIES AND SPARE PARTS
See Accessories section for the entire list.
POLYWARM®
S T O C K
grey
AVAILABILITY
ENERGY
COMBI 1 WB
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
COMBI 1 WC D.H.W. STORAGE EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE Volume Surface ErP
Model insulation
Art. Nr. [lt] [m2]
800 3270162284012 191 1,6 C
1000 3270162284013 226 1,8 C
1500 3270162284014 412 2,5 C
2000 3270162284015 566 3,1 C
Accessories on request
Thermometer Chain magnesium anode (connection 3/4”) Buffer tanks connecting kit
Art. Nr. Art. Nr. For models Art. Nr. Connection
5032240000107 5200000041007 800÷2000 5006170001001 1” 1/2
5 units box 5200000041016 500,600 Stainless steel extensible
N° 2 chain anodes + insulated connecting kit - (200 ÷ 400 mm)
cap + gasket
188
COMBI 1
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH POLYWARM® COATED TANK IN TANK CALORIFIER FOR D.H.W.
TECHNICAL D.H.W.
STORAGE STORAGE
Pmax Tmax Pmax Tmax
BOLLYTERM®
CALORIFIERS
3 bar 99 °C 6 bar 90 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
Df
CALORIFIERS FOR
HEAT PUMP
(24)
H12 (16)
(17) (18)
H11 (15)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H9 (12) (13)
H8 (10) 1-3 Heating return/To Generator 1"1/2 Gas F
A
H7 (9)
5 Connection for instrumentation 1/2" Gas F
H5 (6) (7) 6-7 Heating return/To Generator 1"1/2 Gas F
H4 (5)
HYDRONIC
9 Electrical immersion 1"1/2 Gas F
10 Connection for instrumentation 1/2" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H2 (1) (2) (3) 12-13 Heating return/To additional generator/Heating delivery 1"1/2 Gas F
INERTIAL
TANKS
17 Connection for instrumentation 1/2" Gas F
19 Air purge 1/2" Gas F
(20) (23)
(19) 20 Domestic hot water inlet 3/4" Gas F
WATER PRESSURE
(1) (6) 22 Recirculation 3/4" Gas F
(3) (7)
(21)
TANKS
(12) (16) (13) (18) 23 Connection for instrumentation 1/2" Gas F
Dismountable
insulation
AND SPARE PARTS
ACCESORIES
1000 944 790 1010 950 2180 2374 265 656 787 998 1309 1588 1831
1500 1431 950 1210 1100 2300 2550 313 736 845 1061 1377 1653 1909
2000 1961 1100 1360 1300 2370 2703 347 770 879 1060 1411 1687 1943
189
COMBI 2
MULTI-HEAT ENERGY BUFFER WITH POLYWARM® COATED TANK IN TANK CALORIFIER FOR D.H.W.
AND 1 FIXED HEAT EXCHANGER
APPLICATION - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
Heating hot water storage and D.H.W. production. with high thermal insulation. Fire resistance class B-s2d0 according
MATERIAL to EN 13501.
Buffer tank: Mild steel construction with exterior paint. No anti- Grey PVC external lining complete with top cover
corrosion treatment required due to the buffer’s closed circuit system. CATHODE PROTECTION
D.H.W. storage: Mild steel Polywarm® coated (Attestation ACS - Chain magnesium anode
SSICA - DVGW - W270 - UBA - WRAS) WARRANTY
HEAT EXCHANGER 5 years - See general sales conditions and warranty
1 fixed heat exchanger. ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Multi-Heat Energy tanks Combi2 are used in units with a typically
discontinuous energy source for double use: heating systems and
domestic hot water systems.
INSULATION
- HARD: High thermal insulation with ecological polyurethane hard foam.
POLYWARM®
S T O C K
grey
AVAILABILITY
ENERGY
COMBI 2 WB
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
ENERGY
COMBI 2 WC D.H.W. STORAGE HEAT EXCHANGER EFFICIENCY
CLASS
DISMOUNTABLE SOFT FLEECE Volume Surface Volume Surface ErP
Model insulation
Art. Nr. [lt] [m2] [lt] [m2]
800 3270162284112 191 1,6 20 3,1 C
1000 3270162284113 226 1,8 24 3,7 C
1500 3270162284114 412 2,5 32 4,9 C
2000 3270162284115 566 3,1 35 5,4 C
Accessories on request
Thermometer Chain magnesium anode (connection 3/4”) Buffer tanks connecting kit
Art. Nr. Art. Nr. For models Art. Nr. Connection
5032240000107 5200000041007 800÷2000 5006170001001 1” 1/2
5 units box 5200000041016 500,600 Stainless steel extensible
N° 2 chain anodes + insulated connecting kit - (200 ÷ 400 mm)
cap + gasket
190
COMBI 2
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH POLYWARM® COATED TANK IN TANK CALORIFIER FOR D.H.W.
AND 1 FIXED HEAT EXCHANGER
BOLLYTERM®
CALORIFIERS
Pmax Tmax Pmax Tmax Pmax Tmax
3 bar 99 °C 6 bar 90 °C 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
De
HEAT PUMP
Df
(24)
H12 (16)
CYLINDERS - PUFFER
(17) (18)
MULTIFUEL ENERGY
1-3 Heating return/To Generator 1"1/2 Gas F
H11 (15) 2 Connection for instrumentation 1/2" Gas F
4 Lower fixed heat exchanger outlet 1" Gas F
H9 (12) (13) 5 Connection for instrumentation 1/2" Gas F
H8 (10)
A
HYDRONIC
H6 (8) 9 Electrical immersion 1"1/2 Gas F
H5 (6) (7) 10 Connection for instrumentation 1/2" Gas F
H4 (5) 12-
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
17 Connection for instrumentation 1/2" Gas F
TANKS
0
19 Air purge 1/2" Gas F
20 Domestic hot water inlet 3/4" Gas F
21 Domestic hot water outlet 3/4" Gas F
WATER PRESSURE
(20) (23) 22 Recirculation 3/4" Gas F
(19)
23 Connection for instrumentation 1/2" Gas F
TANKS
(24) (22) 24 Chain magnesium anode 3/4” Gas F
(1) (6) (3) (7)
(21)
(12) (16) (13) (18)
(2) (5) (9) (4) (8)
COMPRESSED AIR
100°
Dismountable
insulation
AND SPARE PARTS
ACCESORIES
1000 944 790 1010 950 2180 2374 265 656 787 998 1309 1588 1831
1500 1431 950 1210 1100 2300 2550 313 736 845 1061 1377 1653 1909
2000 1961 1100 1360 1300 2370 2703 347 770 879 1060 1411 1687 1943
191
COMBI 3
MULTI-HEAT ENERGY BUFFER WITH POLYWARM® COATED TANK IN TANK CALORIFIER FOR D.H.W.
AND 2 FIXED HEAT EXCHANGERS
APPLICATION INSULATION
Heating hot water storage and D.H.W. production. - HARD: High thermal insulation with ecological polyurethane hard foam.
MATERIAL - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
Buffer tank: Mild steel construction with exterior paint. No anti- with high thermal insulation. Fire resistance class B-s2d0 according
corrosion treatment required due to the buffer’s closed circuit system. to EN 13501.
D.H.W. storage: Mild steel Polywarm® coated (Attestation ACS - Grey PVC external lining complete with top cover
SSICA - DVGW - W270 - UBA - WRAS) CATHODE PROTECTION
HEAT EXCHANGERS Chain magnesium anode
2 fixed heat exchangers WARRANTY
TECHNICAL DESCRIPTION 5 years - See general sales conditions and warranty
Multi-Heat Energy tanks Combi3 are used in units with a typically ACCESSORIES AND SPARE PARTS
discontinuous energy source for double use: heating systems and See Accessories section for the entire list.
domestic hot water systems.
POLYWARM®
S T O C K
grey
AVAILABILITY
CLASS
HARD FOAM Volume Surface Volume Surface Volume Surface ErP
Model insulation
Art. Nr. [lt] [m ]
2
[lt] [m ]
2
[lt] [m2]
500 3270162314201 99 1,1 8 1,3 11,5 1,9 C
600 3270162314202 146 1,3 12 1,9 18 2,8 C
800 3270162314203 191 1,6 16 2,4 20 3,1 C
1000 3270162314204 226 1,8 20 3,1 24 3,7 C
1500 3270162314205 412 2,5 23 3,5 32 4,9 C
2000 3270162314206 566 3,1 27 4,1 35 5,4 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Chain magnesium anode (connection 3/4”) Buffer tanks connecting kit
Art. Nr. Art. Nr. For models Art. Nr. Connection
5032240000107 5200000041007 800÷2000 5006170001001 1” 1/2
5 units box 5200000041016 500,600 Stainless steel extensible
N° 2 chain anodes + insulated connecting kit - (200 ÷ 400 mm)
cap + gasket
192
COMBI 3
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH POLYWARM® COATED TANK IN TANK CALORIFIER FOR D.H.W.
AND 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
CALORIFIERS
Pmax Tmax Pmax Tmax Pmax Tmax
3 bar 99 °C 6 bar 90 °C 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as
CALORIFIERS
indicated by Ecodesign ErP Directive.
ASK ALWAYS FOR
CERTIFIED LABORATORIES
DATA RESULTS
De
CALORIFIERS FOR
Df
HEAT PUMP
(24)
H12 (16) 1-3 Heating return/To Generator 1"1/2 Gas F
(17) (18) 2 Connection for instrumentation 1/2" Gas F
H10 (14)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H11 (15) 4 Lower fixed heat exchanger outlet 1" Gas F
5 Connection for instrumentation 1/2" Gas F
H9 (12) (13) 6-7 Heating return/To Generator 1"1/2 Gas F
H8 (10) (11)
A
HYDRONIC
H4 (5) 11 Upper fixed heat exchanger outlet 1" Gas F
INERTIAL
TANKS
17 Connection for instrumentation 1/2" Gas F
19 Air purge 1/2" Gas F
WATER PRESSURE
21 Domestic hot water outlet 3/4" Gas F
(24) (22) 22 Recirculation 3/4" Gas F
TANKS
(1) (6) (3) (7) 23 Connection for instrumentation 1/2" Gas F
(12) (16) (21)
(13) (18) 24 Chain magnesium anode 3/4” Gas F
(2) (5) (9) (10) (4) (8)
(15) (17) (11) (14)
COMPRESSED AIR
RECEIVERS
100°
Dismountable
insulation
AND SPARE PARTS
ACCESORIES
1000 944 790 1010 950 2180 2374 265 284 656 787 953 998 1188 1309 1748 1588 1831
1500 1431 950 1210 1100 2300 2550 313 336 736 845 1006 1061 1286 1377 1805 1653 1909
2000 1961 1100 1360 1300 2370 2703 347 370 770 879 1001 1060 1300 1411 1820 1687 1943
193
COMBI - OUTPUT AND PERFORMANCES
D.H.W. STORAGE PERFORMANCES
COMPLETE HEATED STORAGE VOLUME UPPER PART HEATED STORAGE VOLUME
Max sanitary water produced Max sanitary water produced Max sanitary water produced Max sanitary water produced
DHW DHW exchanger from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C
Model Volume surface with storage with storage with storage with storage
at 65°C and boiler on at 65°C and boiler off at 65°C and boiler on at 65°C and boiler off
Output [KCal/h]
1000
Output [kW]
0 0
0 5 10 15 20 25 30 35
Average Delta[°C]
2000
80
Output [KCal/h]
Output [kW]
1500 60000
60 1000
800
40000
40 600
500
20000
20
0 0
0 5 10 15 20 25 30 35
Average Delta[°C]
194
EXTRA- BOLLY®
COMBI - OUTPUT AND PERFORMANCES
CALORIFIERS
D.H.W. STORAGE PERFORMANCES
BOLLYTERM®
COMPLETE HEATED STORAGE VOLUME UPPER PART HEATED STORAGE VOLUME
CALORIFIERS
Max sanitary water produced Max sanitary water produced Max sanitary water produced Max sanitary water produced
DHW DHW exchanger from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C
Model Volume surface with storage with storage with storage with storage
at 65°C and boiler on at 65°C and boiler off at 65°C and boiler on at 65°C and boiler off
STAINLESS STEEL
[litres] [m2] [lt/min] [litres] [lt/min] [litres]
CALORIFIERS
10 lt/min: 389 lt 10 lt/min: 291 lt
1000 226 1,8 4,1 2,26
25 lt/min: 330 lt 25 lt/min: 250 lt
10 lt/min: 753 lt 10 lt/min: 565 lt
1500 412 2,5 5,6 3,36
25 lt/min: 614 lt 25 lt/min: 461 lt
10 lt/min: 1083 lt 10 lt/min: 812 lt
2000 566 3,1 6,8 4,08
CALORIFIERS FOR
25 lt/min: 852 lt 25 lt/min: 639 lt
HEAT PUMP
PRESSURE LOSS - LOWER FIXED HEAT EXCHANGER COMBI 2 - COMBI 3
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80 90 100
CYLINDERS - PUFFER
MULTIFUEL ENERGY
2000
1000
10000
1500
800 8000
1000
HYDRONIC
600 6000
[mbar]
800
600
[mm H 2 O]
400 4000
500
INERTIAL
200 2000
TANKS
0 0
0 1 2 3 4 5 6
Flow Rate [m3/h]
WATER PRESSURE
PRESSURE LOSS - UPPER FIXED HEAT EXCHANGER COMBI 3
TANKS
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80 90 100
800
8000
2000
COMPRESSED AIR
700
RECEIVERS
7000
1500
600 6000
1000
500 5000
AND SPARE PARTS
800
[mbar]
ACCESORIES
400 4000
600
[mm H 2 O]
300 3000
500
200 2000
100 1000
TECHNICAL
SUPPORT
0 0
0 1 2 3 4 5 6
Flow Rate [m /h] 3
195
ECO-COMBI 1
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
CORRUGATED EFFICIENCY
PIPE FOR D.H.W. PRODUCTION CLASS
HARD FOAM Volume Surface ErP
Model insulation
Art. Nr. [lt] [m2]
500 3270162316010 26,6 4,5 C
600 3270162316011 31,0 5,3 C
800 3270162316012 33,4 5,8 C
1000 3270162316013 45,5 7,8 C
1250 3270162316014 45,5 7,8 C
1500 3270162316015 55,3 9,5 C
2000 3270162316016 72,2 12,3 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 9 400 - TRIPHASE
See accessories
196
ECO-COMBI 1
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
CORRUGATED DHW
STORAGE
STAINLESS STEEL PIPE
BOLLYTERM®
Pmax Tmax Pmax
CALORIFIERS
3 bar 99 °C 6 bar
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(21)
CALORIFIERS FOR
HEAT PUMP
H12 (17)
H13 (20)
(18) (19)
H11 (16) 1 Domestic cold water circuit inlet 1” Gas M
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Heating return/To Generator
2-4
1”1/2 Gas F
H9 (13) (14) 3 Connection for instrumentation 1/2” Gas F
H8 (11) 6 Connection for instrumentation 1/2” Gas F
A
H
HYDRONIC
11 Connection for instrumentation 1/2” Gas F
Heating return/To additional generator
13 - 14
/ Heating delivery1”1/2 Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
20 Domestic hot water outlet 1” Gas M
TANKS
(21)
WATER PRESSURE
TANKS
(2) (7) (4) (8)
(13) (17) (14) (19)
(3) (6) (10)
(11) (16) (18) (1) (20)
COMPRESSED AIR
100°
RECEIVERS
Dismountable
insulation
AND SPARE PARTS
Model
[lt] [mm] [mm]
500 478 // // 750 1619 1745 230 247 533 629 841 1011 1231 1343 1360
600 560 // // 750 1869 1979 230 247 582 695 915 1144 1382 1593 1610
800 803 790 1010 950 1838 2001 248 265 584 690 823 1115 1332 1541 1558
1000 944 790 1010 950 2128 2270 248 265 656 787 998 1309 1588 1831 1843
TECHNICAL
SUPPORT
1250 1248 900 1160 1050 2201 2378 296 313 705 835 986 1357 1586 1879 1896
1500 1432 950 1210 1100 2250 2442 296 313 736 845 1061 1377 1653 1909 1921
2000 1970 1100 1360 1300 2319 2567 330 347 770 879 1060 1411 1687 1943 1955
197
ECO-COMBI 2
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
AND 1 FIXED HEAT EXCHANGER
APPLICATION • Domestic hot water production systems for domestic and sanitary
Heating hot water storage and D.H.W. production. use where heating water is stored. In this system , the high
MATERIAL potentiality of the Eco Combi allows to obtain a good production of
• BUFFER TANK: Mild steel construction with exterior paint. No hot sanitary water even if temperatures of the primary system are
anti-corrosion treatment required due to the buffer’s closed circuit not so high (i.e using heating pumps as primary source and solar
system. source as support).
• D.H.W. STORAGE : 316L stainless steel corrugated pipe, suitable for The particular shape of the corrugated pipe is avoiding any problem
drinkable water according to D. M. n. 174 dated 06.04.04. relating to the storage of sanitary hot water and ensure high heating
HEAT EXCHANGER: exchange performances.
1 fixed heat exchanger. INSULATION
TECHNICAL DESCRIPTION - HARD: High thermal insulation with ecological polyurethane hard foam.
Multi-Heat Energy tanks EcoCombi 2 are used in units with a typically - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
discontinuous energy source for double use: heating system and with high thermal insulation. Fire resistance class B-s2d0 according
sanitary hot water system. to EN 13501.
• Heating system with a biomass generator as energy source, Grey PVC external lining complete with top cover
combining the possibility to produce hot water for sanitary use. In WARRANTY
such case , storage heating volume allows the generator to regularly 5 years - See general sales conditions and warranty
work , limiting number of stops due to the inadeguate energy request ACCESSORIES AND SPARE PARTS
of the heating system. Moreover, it limits the emission of smoke and See Accessories section for the entire list.
the creation of corrosive condensate (smokes side).
D.H.W. STORAGE
S T O C K
grey
AVAILABILITY
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
SOFT FLEECE INSULATION
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 9 400 - TRIPHASE
See accessories
198
ECO-COMBI 2
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
AND 1 FIXED HEAT EXCHANGER
BOLLYTERM®
Pmax Tmax Pmax Pmax Tmax
CALORIFIERS
3 bar 99 °C 6 bar 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
HEAT PUMP
De 1 Domestic cold water circuit inlet 1" Gas M
Df
(21) 2-4 Heating return/To Generator 1"1/2 Gas F
H12 (17) H13 (20) 5 Lower fixed heat exchanger outlet 1" Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
(18) (19)
6 Connection for instrumentation 1/2" Gas F
H11 (16)
7-8 Heating return/To Generator 1"1/2 Gas F
HYDRONIC
H6 (9) Heating return/To additional generator/
H5 (7) (8) 13-14
Heating delivery 1"1/2 Gas F
H4 (6)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
20 Domestic hot water outlet 1" Gas M
0
WATER PRESSURE
TANKS
(21)
100° Dismountable
insulation
Df De De
AND SPARE PARTS
Model
[lt] [mm] [mm]
500 478 // // 750 1619 1745 230 247 260 533 629 744 841 1011 1231 1343 1360
600 560 // // 750 1869 1979 230 247 260 582 695 855 915 1144 1382 1593 1610
800 803 790 1010 950 1838 2001 248 265 278 584 690 762 823 1115 1332 1541 1558
1000 944 790 1010 950 2128 2270 248 265 284 656 787 953 998 1309 1588 1831 1843
TECHNICAL
SUPPORT
1250 1248 900 1160 1050 2201 2378 296 313 326 705 835 884 986 1357 1586 1879 1896
1500 1432 950 1210 1100 2250 2442 296 313 336 736 845 1006 1061 1377 1653 1909 1921
2000 1970 1100 1360 1300 2319 2567 330 347 370 770 879 1001 1060 1411 1687 1943 1955
199
ECO-COMBI 3
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
AND 2 FIXED HEAT EXCHANGERS
APPLICATION • Domestic hot water production systems for domestic and sanitary
Heating hot water storage and D.H.W. production. use where heating water is stored. In this system , the high
MATERIAL potentiality of the Eco Combi allows to obtain a good production of
• BUFFER TANK: Mild steel construction with exterior paint. No hot sanitary water even if temperatures of the primary system are
anti-corrosion treatment required due to the buffer’s closed circuit not so high (i.e using heating pumps as primary source and solar
system. source as support)
• D.H.W. STORAGE: 316L stainless steel corrugated pipe, suitable for The particular shape of the corrugated pipe is avoiding any problem
drinkable water according to D. M. n. 174 dated 06.04.04 relating to the storage of sanitary hot water and ensure high heating
HEAT EXCHANGER: exchange performances.
2 fixed heat exchangers. INSULATION
TECHNICAL DESCRIPTION - HARD: High thermal insulation with ecological polyurethane hard foam.
Multi-Heat Energy tanks EcoCombi 3 are used in units with a typically - SOFT: NOFIRE® polyester fleece 100% made of recyclable material,
discontinuous energy source for double use: heating system and with high thermal insulation. Fire resistance class B-s2d0 according
sanitary hot water system . to EN 13501.
• Heating system with a biomass generator as energy source, Grey PVC external lining complete with top cover
combining the possibility to produce hot water for sanitary use. In WARRANTY
such case , storage heating volume allows the generator to regularly 5 years - See general sales conditions and warranty
work , limiting number of stops due to the inadeguate energy request ACCESSORIES AND SPARE PARTS
of the heating system. Moreover, it limits the emission of smoke and See Accessories section for the entire list.
the creation of corrosive condensate (smokes side).
D.H.W. STORAGE
S T O C K
grey
AVAILABILITY
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
da 4 a 9 400 - TRIPHASE
See accessories
200
ECO-COMBI 3
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
AND 2 FIXED HEAT EXCHANGERS
BOLLYTERM®
Pmax Tmax Pmax Pmax Tmax
CALORIFIERS
3 bar 99 °C 6 bar 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(21)
CALORIFIERS FOR
HEAT PUMP
H12 (17) H13 (20)
(18) (19)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H9 (13) (14)
1 Domestic cold water circuit inlet 1" Gas M
H8 (11) (12) 2-4 Heating return/To Generator 1"1/2 Gas F
A
H7 (10)
5 Lower fixed heat exchanger outlet 1" Gas F
H6 (9)
H5 (7) (8) 6 Connection for instrumentation 1/2" Gas F
H4 (6)
HYDRONIC
7-8 Heating return/To Generator 1"1/2 Gas F
9 Lower fixed heat exchanger inlet 1" Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
15 Upper fixed heat exchanger inlet 1" Gas F
16 Connection for instrumentation 1/2" Gas F
17-19-21 Heating return / Heating delivery 1"1/2 Gas F
WATER PRESSURE
18 Connection for instrumentation 1/2" Gas F
20 Domestic hot water outlet 1" Gas M
TANKS
(21)
100°
Dismountable
insulation
Df De De
AND SPARE PARTS
Model
[litres] [mm] [mm]
500 478 // // 750 1619 1745 230 247 260 533 629 744 841 930 1011 1231 1231 1343 1360
600 560 // // 750 1869 1979 230 247 260 582 695 855 915 1060 1144 1361 1382 1593 1610
800 803 790 1010 950 1838 2001 248 265 278 584 690 762 823 988 1115 1332 1332 1541 1558
1000 944 790 1010 950 2128 2270 248 265 284 656 787 953 998 1188 1309 1661 1588 1831 1843
TECHNICAL
SUPPORT
1250 1248 900 1160 1050 2201 2378 296 313 326 705 835 884 986 1068 1357 1641 1586 1879 1896
1500 1432 950 1210 1100 2250 2442 296 313 336 736 845 1006 1061 1286 1377 1673 1653 1909 1921
2000 1970 1100 1360 1300 2319 2567 330 347 370 770 879 1001 1060 1300 1411 1687 1687 1943 1955
201
ECO-COMBI - OUTPUT AND PERFORMANCES
D.H.W. STORAGE PERFORMANCES
Max sanitary water produced Max sanitary water produced Max sanitary water produced Max sanitary water produced
DHW DHW exchanger from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C
Model Volume surface with storage with storage with storage with storage
at 65°C and boiler on at 65°C and boiler off at 65°C and boiler on at 65°C and boiler off
ECO COMBI 2 - ECO COMBI 3 LOWER FIXED HEAT EXCHANGERS POWERS CHART
[KCal/h]
2000 LT 80000
Potenza [KCal/h]
[kW]
80
m3/h at 80 °C inlet and outlet at 70 °C, has on the storage of 1500 LT
Output
60000
1250 LT
Output
water an average temperature of 60 °C, the mean difference of 60 1000 LT
temperature will be: 800 LT
40000
(80 +70) / 20-60 = 15 °C and therefore you can exchange up to 40 600 LT
approximately 32 kW. 500 LT
20000
20
0 0
0 5 10 15 20 25 30 35
Delta T medio [°C]
Average Delta[°C]
50
1000-1250
40000
40
Output [KCal/h]
800 30000
Output [kW]
30
500-600
20000
20
10000
10
0 0
0 5 10 15 20 25 30 35
Average Delta[°C]
202
ECO-COMBI - OUTPUT AND PERFORMANCES
EXTRA- BOLLY®
CALORIFIERS
D.H.W. STORAGE PERFORMANCES
BOLLYTERM®
CALORIFIERS
Max sanitary water produced Max sanitary water produced Max sanitary water produced Max sanitary water produced
DHW DHW exchanger from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C from 10°C to 45°C
Model Volume surface with storage with storage with storage with storage
at 65°C and boiler on at 65°C and boiler off at 65°C and boiler on at 65°C and boiler off
STAINLESS STEEL
1000 45,5 7,8 50 27
CALORIFIERS
25 lt/min: 541 lt 25 lt/min: 216 lt
10 lt/min: 922 lt 10 lt/min: 310 lt
1250 45,5 7,8 50 27
25 lt/min: 592 lt 25 lt/min: 230 lt
10 lt/min: 1144 lt 10 lt/min: 345 lt
1500 55,3 9,5 57 34
25 lt/min: 735 lt 25 lt/min: 258 lt
10 lt/min: 1657 lt 10 lt/min: 463 lt
CALORIFIERS FOR
2000 72,2 12,3 74 44
25 lt/min: 1142 lt 25 lt/min: 340 lt
HEAT PUMP
PRESSURE LOSS - LOWER FIXED HEAT EXCHANGER ECO COMBI 2 - ECO COMBI 3
Flow Rate [lt/min]
CYLINDERS - PUFFER
0 20 40 60 80 100 120 140
MULTIFUEL ENERGY
900
9000
2000
800 8000
600 1250
6000
1000
[mm h2o]
500
HYDRONIC
5000
[mbar]
800
400 4000
500 - 600
300 3000
200 2000
INERTIAL
100 1000
TANKS
0 0
0 1 2 3 4 5 6 7 8 9
Flow Rate [m3/h]
WATER PRESSURE
PRESSURE LOSS - UPPER FIXED HEAT EXCHANGER ECO COMBI 3
TANKS
Flow Rate [lt/min]
0 10 20 30 40 50 60 70 80 90 100
600
6000
COMPRESSED AIR
RECEIVERS
1500-2000
500 5000
1000-1250
400 4000
AND SPARE PARTS
[mm h2o]
[mbar]
800
ACCESORIES
300 3000
500- 600
200 2000
100 1000
TECHNICAL
SUPPORT
0 0
0 1 2 3 4 5 6
Flow Rate [m /h] 3
203
ECO-COMBI 1 DOMUS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
D.H.W. STORAGE
SOFT FLEECE INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Max sanitary water produced Max sanitary water produced
from 10°C to 45°C with from 10°C to 45°C with storage
Model
storage at 60°C at 50°C
[lt/min] [lt/min]
www.cordivari.com/erp 200 11 8
On line ErP label tool 300 23 16
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
See accessories
204
ECO-COMBI 1 DOMUS
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
CORRUGATED DHW
STORAGE
STAINLESS STEEL PIPE
BOLLYTERM®
Pmax Tmax Pmax
CALORIFIERS
3 bar 99 °C 6 bar
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
Df
CALORIFIERS FOR
(16)
HEAT PUMP
1 Domestic cold water circuit inlet 1” M
H9 (12) (13)
H10 (14) (15) 2 Heating return/To Generator 1”1/2 F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
3 Connection for instrumentation 1/2” F
H4 (7)
8 To additional generator 1” 1/2 F
A
H3 (6)
HYDRONIC
10 Connection for instrumentation 1/2” F
INERTIAL
TANKS
15 Domestic hot water outlet 1/2” F
WATER PRESSURE
TANKS
(16)
(5) (7) (12) (2) (8) (13)
COMPRESSED AIR
Volume Df H A H1 H2 H3 H4 H5 H7 H8 H9 H10
Model
[lt] [mm]
200 180 590 1309 1436 227 252 552 602 702 852 822 1052 1079
TECHNICAL
SUPPORT
300 279 690 1357 1522 257 272 572 622 722 872 812 1072 1084
205
ECO-COMBI 2 DOMUS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
AND 1 FIXED HEAT EXCHANGER
APPLICATION of the heating systems. Moreover, it limits the emission of smoke
Heating hot water storage and D.H.W. production. and the creation of corrosive condensate (smokes side).
MATERIAL • Domestic hot water production systems for domestic and sanitary
• BUFFER TANK: Mild steel construction with exterior paint. No use where heating water is stored. In this system , the high
anti-corrosion treatment required due to the buffer’s closed circuit potentiality of the Eco Combi allows to obtain a good production of
system. hot sanitary water even if temperatures of the primary system are
• D.H.W. STORAGE: 316L stainless steel corrugated pipe, suitable for not so high (i.e using heating pumps as primary source and solar
drinkable water according to D. M. n. 174 dated 06.04.04. source as support).
HEAT EXCHANGER The particular shape of the corrugated pipe avoids any problem
1 fixed heat exchanger. relating to the storage of sanitary hot water and ensures high heating
TECHNICAL DESCRIPTION exchange performances.
Multi-Heat Energy tanks EcoCombi 2 Domus are used in units with a INSULATION
typically discontinuous energy source for double use: heating system High thermal insulation with ecological hard polyurethane foam. Grey
and domestic hot water systems. PVC external lining
• Heating system with a biomass generator as energy source, WARRANTY
combining the possibility to produce hot water for sanitary use. In 5 years - See general sales conditions and warranty
such case, storage heating volume allows the generator to regularly ACCESSORIES AND SPARE PARTS
work, limiting number of stops due to the inadeguate energy request See Accessories section for the entire list.
D.H.W. STORAGE
S T O C K
grey
AVAILABILITY
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Max sanitary water produced Max sanitary water produced
Max solar collectors
from 10°C to 45°C with from 10°C to 45°C with storage
Model surface
storage at 60°C at 50°C
[m2] [lt/min] [lt/min]
www.cordivari.com/erp 200 5 11 8
On line ErP label tool 300 7,5 23 16
Accessories on request
Monophase and threephase electrical immersion Thermometer Buffer tanks connecting kit
Art. Nr. Art. Nr. Connection
5032240000107 5006170001001 1” 1/2
5 units box Stainless steel extensible
Available kit: connecting kit - (200 ÷ 400 mm)
[Kw] Tension [V]
da 1,5 a 3 220 - MONOPHASE
See accessories
206
ECO-COMBI 2 DOMUS
EXTRA- BOLLY®
CALORIFIERS
MULTI-HEAT ENERGY BUFFER WITH 316L STAINLESS STEEL D.H.W. CORRUGATED PIPE
AND 1 FIXED HEAT EXCHANGER
BOLLYTERM®
Pmax Tmax Pmax Pmax Tmax
CALORIFIERS
3 bar 99 °C 6 bar 12 bar 110 °C
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
CALORIFIERS FOR
Df
HEAT PUMP
(16)
CYLINDERS - PUFFER
2 Heating return/To Generator 1"1/2 Gas F
MULTIFUEL ENERGY
H9 (12)(13)
3 Connection for instrumentation 1/2" Gas F
4 To solar thermal system 1" Gas F
HYDRONIC
A
INERTIAL
TANKS
14 Connection for instrumentation 1/2" Gas F
0 15 Domestic hot water outlet 1/2" Gas F
16 Heating delivery/From Generator 1"1/2 Gas F
WATER PRESSURE
TANKS
(16)
(5)(7)(12) (2)(8)(13)
COMPRESSED AIR
RECEIVERS
(4)(9) (1)(11)(15)
(3)(6)(10)(14)
AND SPARE PARTS
ACCESORIES
TECHNICAL
Volume De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10
SUPPORT
Model
[lt]
200 180 590 1309 1436 227 252 552 602 702 822 852 822 1052 1079
300 279 690 1357 1521 257 272 572 622 722 812 872 812 1072 1084
207
PUFFERMAS® 1
HEATING WATER BUFFER TANK WITH MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
ENERGY
PUFFERMAS® 1 VB EFFICIENCY
CLASS
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
120 kW SLB40/ 40
1500 3251162314709 C
PATENTED
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
208
PUFFERMAS® 1
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
BOLLYTERM®
Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS 1-2-6-7 Heating return/To Generator1"1/2 Gas F
CALORIFIERS FOR
11 Connection for instrumentation 1/2" Gas F
(19)
HEAT PUMP
12-13-
Heating delivery/ Heating return 1"1/2 Gas F
16-18
14 - 17 Connection for instrumentation 1/2" Gas F
H13 (16)
(17) (18) 19 Heating delivery 1”1/2 Gas F
H11 (14)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
20 Domestic cold water circuit inlet 3/4” Gas M (1” Gas M for models 120kW)
H10 (12) (13) H9(11) 21 Domestic hot water circuit outlet 3/4” Gas M (1” Gas M for models 120kW)
H
H7 (9)
H5 (6) (7)
A
H4 (5) (19)
HYDRONIC
H3 (4)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
(20) (21) Dismountable
insulation
WATER PRESSURE
500 478 750 1619 1784 247 360 533 629 870 1025 1011 1130 1343
TANKS
600 560 750 1870 2015 247 360 582 695 970 1200 1144 1485 1593
800 805 950 1840 2066 265 378 584 690 918 1115 1115 1442 1541
1000 946 950 2130 2328 265 384 656 787 1145 1388 1309 1588 1831
1500 1454 1100 2250 2504 313 432 736 845 1236 1396 1377 1783 1909
COMPRESSED AIR
M A Domestic Hot Water exit MACS® module is an external unit that immediately
B A produces hot domestic water, using the heat energy stored
B Domestic Water entry
C Stainless Steel Plate Exchanger in the Buffer thanks to the stainless steel plate exchanger,
D Control for thermostatic head granting safety and comfort with the possibility to regulate
N outlet temperature.
AND SPARE PARTS
O
SUPPORT
209
PUFFERMAS® 2
HEATING WATER BUFFER TANK WITH 1 FIXED HEAT EXCHANGER AND
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
APPLICATION - to produce more DHW than the quantity obtained by boiler with
Storage of heating hot water and immediate production of D.H.W. similar capacity because heating hot water is stored at an higher
high flow rate. temperature than DHW
MATERIAL INSULATION
Mild steel construction with exterior paint. No anti-corrosion Buffer tank: High thermal insulation with ecological hard polyurethane
treatment required due to the buffer’s closed circuit system. foam.
D.H.W. HEAT EXCHANGER MACS® module: insulating PPE cover.
Plate to plate stainless steel exchanger in external MACS® module for Grey PVC external lining
immediate D.H.W. production. WARRANTY
HEATING WATER HEAT EXCHANGER 5 years (tank)
1 fixed heat exchanger See general sales conditions and warranty for electrical parts.
TECHNICAL DESCRIPTION ACCESSORIES AND SPARE PARTS
The immediate and fast production of D.H.W. granted by the outside See Accessories section for the entire list.
system steel plate exchange allow the following benefits:
- to reduce dimensions of the water heater needed
- easy maintenance
- maximum hygiene for anti-legionellosis bacteria’s
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
120 kW SLB40/ 40
1500 3251162314729 3,8 C
PATENTED
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
210
PUFFERMAS® 2
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH 1 FIXED HEAT EXCHANGER AND
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
BOLLYTERM®
Pmax Tmax Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 12 bar 110 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
4-5 Connection for instrumentation 1/2" Gas F
(19)
HEAT PUMP
8 Lower heat exchanger inlet 1" Gas F
9 Electrical immersion 1"1/2 Gas F
11 Connection for instrumentation 1/2" Gas F
H13 (16) 12-13-16-18 Heating delivery/ Heating return 1"1/2 Gas F
(17) (18)
14-17 Connection for instrumentation 1/2" Gas F
H11 (14)
CYLINDERS - PUFFER
19 Heating delivery 1”1/2 Gas F
MULTIFUEL ENERGY
20 Domestic cold water circuit inlet 3/4” Gas M (1” Gas M for models 120kW)
H10 (12) (13) H9(11) 21 Domestic hot water circuit outlet 3/4” Gas M (1” Gas M for models 120kW))
H
H7 (9)
H6 (8)
A
H5 (6) (7)
H4 (5) (19)
HYDRONIC
H3 (4)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)(2) H2 (3)
(1) (6) (12) (2) (7) (9)
(16) (13) (18)
0 (3)(4)(5)
50° (8)(11) 50°
INERTIAL
TANKS
(14)(17)
(20) (21) Dismountable
insulation
WATER PRESSURE
500 478 750 1619 1784 247 260 360 533 629 744 870 1025 1011 1130 1343
TANKS
600 560 750 1870 2015 247 260 360 582 695 855 970 1200 1144 1485 1593
800 805 950 1840 2066 265 278 378 584 690 762 918 1115 1115 1442 1541
1000 946 950 2130 2328 265 284 384 656 787 953 1145 1388 1309 1588 1831
1500 1454 1100 2250 2504 313 336 432 736 845 1006 1236 1396 1377 1783 1909
COMPRESSED AIR
M A Domestic Hot Water exit MACS® module is an external unit that immediately
B A produces hot domestic water, using the heat energy stored
B Domestic Water entry
C Stainless Steel Plate Exchanger in the Buffer thanks to the stainless steel plate exchanger,
D Control for thermostatic head granting safety and comfort with the possibility to regulate
N outlet temperature.
AND SPARE PARTS
O
SUPPORT
211
PUFFERMAS® 3
HEATING WATER BUFFER TANK WITH 2 FIXED HEAT EXCHANGERS AND
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
APPLICATION - to produce more DHW than the quantity obtained by boiler with
Storage of heating hot water and immediate production of D.H.W. similar capacity because heating hot water is stored at an higher
high flow rate. temperature than DHW
MATERIAL INSULATION
Mild steel construction with exterior paint. No anti-corrosion Buffer tank: High thermal insulation with ecological hard polyurethane
treatment required due to the buffer’s closed circuit system. foam. Models 800-1000 available with dismountable hard foam
D.H.W. HEAT EXCHANGER insulation
Plate to plate stainless steel exchanger in external MACS® module for MACS® module: insulating PPE cover.
immediate D.H.W. production. Grey PVC external lining
HEATING WATER HEAT EXCHANGER WARRANTY
2 fixed heat exchangers 5 years (tank)
TECHNICAL DESCRIPTION See general sales conditions and warranty for electrical parts.
The immediate and fast production of D.H.W. granted by the outside ACCESSORIES AND SPARE PARTS
system steel plate exchange allow the following benefits: See Accessories section for the entire list.
- to reduce dimensions of the water heater needed
- easy maintenance
- maximum hygiene for anti-legionellosis bacteria’s
ENERGY
PUFFERMAS® 3 VB HEAT EXCHANGERS SURFACE EFFICIENCY
CLASS
HARD FOAM INSULATION
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
120 kW SLB40/ 40
1500 3251162314749 2,8 3,8 C
PATENTED
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
212
PUFFERMAS® 3
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH 2 FIXED HEAT EXCHANGERS AND
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
BOLLYTERM®
Pmax Tmax Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 12 bar 110 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
CALORIFIERS FOR
3 14 - 17
(19) Gas F 1/2" Gas F
HEAT PUMP
Connection for instrumentation
4-5 15 Upper heat exchanger inlet 1" Gas F
1/2" Gas F
H13 (16) 8 Lower heat exchanger inlet 1" Gas F 19 Heating delivery 1"1/2 Gas F
(17) (18) H12(15) Domestic cold water circuit inlet 3/4”
H11 (14) 9 Electrical immersion 1"1/2 Gas F 20
Gas M (1” Gas M for models 120kW)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Upper heat exchanger outlet 1" Domestic hot water circuit outlet
10
H10 (12) (13) Gas F 21 3/4” Gas M (1” Gas M for models
H9(11) Connection for instrumentation
H8 (10) 11 120kW)
1/2" Gas F
H
H7 (9)
H6 (8)
H5 (6) (7)
A
H4 (5)
HYDRONIC
(19)
H3 (4)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)(2) H2 (3)
(1) (6) (12) (2) (7) (9)
(16) (13) (18)
0 (3)(4)(5)
INERTIAL
50° 50°
TANKS
(8)(10)(11)
Dismountable
(14)(15)(17) insulation
(20) (21)
WATER PRESSURE
[lt] [mm]
500 478 750 1619 1784 247 260 360 533 629 744 870 930 1025 1011 1130 1231 1343
TANKS
600 560 750 1870 2015 247 260 360 582 695 855 970 1090 1200 1144 1485 1391 1593
800 805 950 1840 2066 265 278 378 584 690 762 918 1003 1115 1115 1442 1347 1541
1000 946 950 2130 2328 265 284 384 656 787 953 1145 1188 1388 1309 1588 1661 1831
1500 1454 1100 2250 2504 313 336 432 736 845 1006 1236 1286 1396 1377 1783 1673 1909
COMPRESSED AIR
M A Domestic Hot Water exit MACS® module is an external unit that immediately
B A produces hot domestic water, using the heat energy stored
B Domestic Water entry
C Stainless Steel Plate Exchanger in the Buffer thanks to the stainless steel plate exchanger,
D Control for thermostatic head granting safety and comfort with the possibility to regulate
N outlet temperature.
AND SPARE PARTS
O
SUPPORT
213
PUFFERMAS® 2 CTS
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE, 1 FIXED HEAT EXCHANGER
AND MACS® D.H.W. STATION FOR INSTANTANEOUS PRODUCTION OF SANITARY WATER
APPLICATION MACS® DHW station) with a new stratification device that conveys
Storage of heating hot water with stratification device and D.H.W in the upper part of the tank the water heated up by the lower fixed
immediate production with high flow rate. exchanger. This combination ensures a perfect natural stratification
MATERIAL inside the tank with no valve or additional external device.
Mild steel construction with exterior paint. No anti-corrosion The lower fixed exchanger allows the possibility of connecting with a
treatment required due to the buffer’s closed circuit system. solar system. Being positioned at the bottom lower part of the buffer
D.H.W. HEAT EXCHANGER tank and with very small footprint, it increases the volume available
Plate to plate stainless steel exchanger in external MACS® module for for the storage.
immediate D.H.W. production. INSULATION
HEATING WATER HEAT EXCHANGER Buffer tank: High thermal insulation with ecological hard polyurethane
1 mild steel fixed heat exchanger. foam. Models 800-1000 available with dismountable hard foam
TECHNICAL DESCRIPTION insulation
The immediate and fast production of D.H.W. granted by the outside MACS® module: insulating PPE cover.
system steel plate exchange allow the following benefits: Grey PVC external lining
- to reduce dimensions of the water heater needed WARRANTY
- easy maintenance 5 years (tank)
- maximum hygiene for anti-legionellosis bacteria’s See general sales conditions and warranty for electrical parts.
- to produce more DHW than the quantity obtained by calorifier with ACCESSORIES AND SPARE PARTS
similar capacity because heating hot water is stored at an higher See Accessories section for the entire list.
temperature than DHW.
Puffermas 2 CTS® is characterized by multiple thermal stratification
system based on the combination of Cordivari Labyrinth spreader
for returning heating water (both from heating installation and from
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
1500 3251162316409 3,8 C
PATENTED
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
214
PUFFERMAS® 2 CTS
EXTRA- BOLLY®
CALORIFIERS
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE, 1 FIXED HEAT EXCHANGER
AND MACS® D.H.W. STATION FOR INSTANTANEOUS PRODUCTION OF SANITARY WATER
BOLLYTERM®
Pmax Tmax Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 12 bar 110 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
Df
CALORIFIERS FOR
(19) 1-2-6-7 Heating return/To Generator1"1/2 Gas F
HEAT PUMP
3 Lower heat exchanger outlet 1" Gas F
4-5 Connection for instrumentation 1/2" Gas F
H13 (16)
(17) (18) 8 Lower heat exchanger inlet 1" Gas F
H11 (14) 9 Electrical immersion 1"1/2 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
11 Connection for instrumentation 1/2" Gas F
H10 (12) (13) H9(11) 12-13-16-18 Heating delivery/ Heating return 1"1/2 Gas F
H
H5 (6) (7)
21 Domestic hot water circuit outlet 3/4” Gas M (1” Gas M for models 120kW)
H4 (5)
HYDRONIC
H6 (8)
H3 (4)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)(2)
H2 (3)
INERTIAL
TANKS
WATER PRESSURE
TANKS
(19)
(16)
RECEIVERS
(4)(5)(11)
50° (14)(17) 50°
SUITABLE FOR THERMAL
(20) (21)
SOLAR SYSTEMS
THE ILLUSTRATION UNDERLINES THE
STRATIFICATION PROCESS (FROM TOP
AND SPARE PARTS
600 560 750 1870 2015 247 215 360 582 695 425 970 1200 1144 1485 1593
800 805 940 1840 2066 265 233 378 584 690 443 918 1115 1115 1442 1541
1000 946 940 2130 2328 265 233 384 656 787 443 1145 1388 1309 1588 1831
1500 1454 1100 2250 2504 313 281 432 736 845 491 1236 1396 1377 1783 1909
215
PUFFERMAS® 3 CTS
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE, 2 FIXED HEAT EXCHANGERS
AND MACS® D.H.W. STATION FOR INSTANTANEOUS PRODUCTION OF SANITARY WATER
APPLICATION Puffermas 3 CTS® is characterized by multiple thermal stratification
Storage of heating hot water with stratification device and D.H.W system based on the combination of Cordivari Labyrinth spreader
immediate production with high flow rate. Ideal for solar thermal for returning heating water (both from heating installation and from
solutions and for heating systems with mixed energy sources such MACS® DHW station) with a new stratification device that conveys in
as biomass and solar and even allowing the integration of a third the upper part of the tank the water heated up by the lower fixed coil.
energy source. This combination ensures a perfect natural stratification inside the
MATERIAL tank with no valve or additional external device.
Mild steel construction with exterior paint. No anti-corrosion The lower fixed coil allows the possibility of connecting with a solar
treatment required due to the buffer’s closed circuit system. system. Being positioned at the bottom lower part of the buffer tank
D.H.W. HEAT EXCHANGER and with very small footprint, it increases the volume available for
Plate to plate stainless steel exchanger in external MACS® module for the storage.
immediate D.H.W. production. INSULATION
HEATING WATER HEAT EXCHANGER Buffer tank: High thermal insulation with ecological hard polyurethane
2 fixed heat exchangers foam. Models 800-1000 available with dismountable hard foam
TECHNICAL DESCRIPTION insulation
The immediate and fast production of D.H.W. granted by the outside MACS® module: insulating PPE cover.
system steel plate exchange allow the following benefits: Grey PVC external lining
- to reduce dimensions of the water heater needed WARRANTY
- easy maintenance 5 years (tank)
- maximum hygiene for anti-legionellosis bacteria’s See general sales conditions and warranty for electrical parts.
- to produce more DHW than the quantity obtained by calorifier with ACCESSORIES AND SPARE PARTS
similar capacity because heating hot water is stored at an higher See Accessories section for the entire list.
temperature than DHW.
ENERGY
PUFFERMAS® 3 CTS VB HEAT EXCHANGERS SURFACE EFFICIENCY
HARD FOAM INSULATION
CLASS
MACS® modu- HARD FOAM SLB heat Upper Lower ErP
Model le maximum insulation exchanger model /
output Art. Nr. plates nr. [lt] [m2]
500 3251162316423 1,3 1,9 C
600 3251162316424 1,3 2,1 C
800 70 kW 3251162316425 SLB20 / 34 1,8 2,5 C
1000 3251162316426 2,5 3,1 C
1500 3251162316427 2,8 3,8 C
1000 3251162316428 2,5 3,1 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
120 kW SLB40/ 40
1500 3251162316429 2,8 3,8 C
PATENTED
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
216
PUFFERMAS® 3 CTS
EXTRA- BOLLY®
CALORIFIERS
STORAGE BUFFER TANKS FOR HEATING WATER WITH STRATIFICATION DEVICE, 2 FIXED HEAT EXCHANGERS AND MACS® D.H.W.
STATION FOR INSTANTANEOUS PRODUCTION OF SANITARY WATER
BOLLYTERM®
Pmax Tmax Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 12 bar 110 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
1-2-6-7 Heating return/To Generator1"1/2 Gas F
3 Lower heat exchanger outlet 1" Gas F
4-5 Connection for instrumentation 1/2" Gas F
De
Df 8 Lower heat exchanger inlet 1" Gas F
CALORIFIERS FOR
(19) 9 Electrical immersion 1"1/2 Gas F
HEAT PUMP
11 Connection for instrumentation 1/2" Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Domestic cold water circuit inlet 3/4” Gas M
H10 (12) (13) 20
H9(11) (1” Gas M for models 120kW)
H8 (10)
H
Domestic hot water circuit outlet 3/4” Gas M (1” Gas M for models
21
H7 (9) 120kW)
A
H5 (6) (7)
H4 (5)
HYDRONIC
H6 (8)
H3 (4)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)(2)
H2 (3)
INERTIAL
TANKS
WATER PRESSURE
(19)
(14)(15)(17)
600 650 750 1870 2015 247 215 360 582 695 425 970 1090 1200 1144 1485 1391 1593
800 790 940 1840 2066 265 233 378 584 690 443 918 1003 1115 1115 1442 1347 1541
1000 790 940 2130 2328 265 233 384 656 787 443 1145 1188 1388 1309 1588 1661 1831
1500 950 1100 2250 2504 313 281 432 736 845 491 1236 1286 1396 1377 1783 1673 1909
217
PUFFERMAS® 2 CTS POWER
HEATING WATER BUFFER TANK WITH 1 FIXED HEAT EXCHANGER, INTEGRATED SOLAR CIRCULATION GROUP,
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
APPLICATION - to reduce dimensions of the water heater needed
Storage by stratification of heating water, instantaneous production - easy maintenance
of domestic hot water (DHW) with high flows and performances and - maximum hygiene for anti-legionellosis bacteria’s
also management of the solar circulation, in solar thermal system / - to produce more DHW than the quantity obtained by boiler with
biomass boiler. similar capacity because heating hot water is stored at an higher
MATERIAL temperature than DHW.
Mild steel construction with exterior paint. No anti-corrosion INSULATION
treatment required due to the buffer’s closed circuit system. Buffer tank: High thermal insulation with ecological hard polyurethane
D.H.W. HEAT EXCHANGER foam. Models 800-1000 available with dismountable hard foam
Plate to plate stainless steel exchanger in external MACS® module for insulation
immediate D.H.W. production. Macs® module and solar circulation group: insulating PPE cover.
SOLAR STATION: Grey PVC external lining
Solar station cabled components on the tank (circulation group- WARRANTY
Professional central unit with 5 temperature probes) 5 years (tank)
HEATING WATER HEAT EXCHANGER See general sales conditions and warranty for electrical parts.
1 mild steel fixed heat exchanger. ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Specific for accumulation and management of the heat produced
by the thermal solar system, combines the use of the Puffer’s
characteristics with the ones of a fast DHW producer without the
storage of domestic hot water, with the following advantages:
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
1500 3251162316449 3,8 C
PATENTED
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
218
PUFFERMAS® 2 CTS POWER
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH 1 FIXED HEAT EXCHANGER, INTEGRATED SOLAR CIRCULATION GROUP,
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
BOLLYTERM®
Pmax Tmax Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 12 bar 110 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(19)
CALORIFIERS FOR
HEAT PUMP
1-2-6-7 Heating return/To Generator1"1/2 Gas F
H13 (16) 3 Lower heat exchanger outlet 1" Gas F
(17) (18)
4-5 Connection for instrumentation 1/2" Gas F
H11 (14)
8 Lower heat exchanger inlet 1" Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H9(11)
11 Connection for instrumentation 1/2" Gas F
H
HYDRONIC
H3 (4) Domestic hot water circuit outlet 3/4” Gas M (1” Gas M for models
H1 (1)(2) 21
120kW)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
TANKS
WATER PRESSURE
(19)
TANKS
(1) (6) (12) (2) (7) (9)
(16) (13) (18)
(4)(5)(11)
COMPRESSED AIR
800 805 940 1840 2066 265 233 378 584 690 443 918 1115 1115 1442 1541
1000 946 940 2130 2328 265 233 384 656 787 443 1145 1388 1309 1588 1831
1500 1454 1100 2250 2504 313 281 432 736 845 491 1236 1396 1377 1783 1909
219
PUFFERMAS® 3 CTS POWER
HEATING WATER BUFFER TANK WITH 2 FIXED HEAT EXCHANGERS, INTEGRATED SOLAR CIRCULATION GROUP,
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
APPLICATION - to reduce dimensions of the water heater needed
Storage by stratification of heating water, instantaneous production - easy maintenance
of domestic hot water (DHW) with high flows and performances and - maximum hygiene for anti-legionellosis bacteria’s
also management of the solar circulation, in solar thermal system / - to produce more DHW than the quantity obtained by boiler with
biomass boiler. similar capacity because heating hot water is stored at an higher
MATERIAL temperature than DHW.
Mild steel construction with exterior paint. No anti-corrosion INSULATION
treatment required due to the buffer’s closed circuit system. Buffer tank: High thermal insulation with ecological hard polyurethane
D.H.W. HEAT EXCHANGER foam. Models 800-1000 available with dismountable hard foam
Plate to plate stainless steel exchanger in external MACS® module for insulation
immediate D.H.W. production. Macs® module and solar circulation group: insulating PPE cover.
SOLAR STATION: Grey PVC external lining
Solar station cabled components on the tank (circulation group- WARRANTY
Professional central unit with 5 temperature probes) 5 years (tank)
HEATING WATER HEAT EXCHANGER See general sales conditions and warranty for electrical parts.
2 mild steel fixed heat exchangers. ACCESSORIES AND SPARE PARTS
TECHNICAL DESCRIPTION See Accessories section for the entire list.
Specific for accumulation and management of the heat produced
by the thermal solar system, combines the use of the Puffer’s
characteristics with the ones of a fast DHW producer without the
storage of domestic hot water, with the following advantages:
SURFACE CLASS
MACS® HARD FOAM
module insulation SLB heat exchanger Upper Lower ErP
Model maximum model / plates nr.
MACS® module output Art. Nr. [lt] [m2]
500 3251162316463 1,3 1,9 C
600 3251162316464 1,3 2,1 C
800 70 kW 3251162316465 SLB20 / 34 1,8 2,5 C
Integrated 1000 3251162316466 2,5 3,1 C
solar station 1500 3251162316467 2,8 3,8 C
1000 3251162316468 2,5 3,1 C
120 kW SLB40/ 40
1500 3251162316469 2,8 3,8 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
PATENTED
www.cordivari.com/erp
On line ErP label tool
Accessories on request
Thermometer Recirculation kit Buffer tanks connecting kit
Art. Nr. Art. Nr. Art. Nr. Connection
5032240000107 5221000000054 5006170001001 1” 1/2
5 units box Control display + pump Stainless steel extensible
(for D.H.W.) connecting kit - (200 ÷ 400 mm)
220
PUFFERMAS® 3 CTS POWER
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER BUFFER TANK WITH 2 FIXED HEAT EXCHANGERS, INTEGRATED SOLAR CIRCULATION GROUP,
MACS® MODULE FOR IMMEDIATE D.H.W. PRODUCTION
BOLLYTERM®
Pmax Tmax Pmax Tmax Pmax Tmax F max
CALORIFIERS
3 bar 99 °C 12 bar 110 °C 6 bar 99 °C 30 °f
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming
STAINLESS STEEL
to European standard EN 15332, as ASK ALWAYS FOR
CALORIFIERS
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
DATA RESULTS
De
Df
(19)
CALORIFIERS FOR
HEAT PUMP
1-2-6-7 Heating return/To Generator1"1/2 Gas F
3 Lower heat exchanger outlet 1" Gas F
H13 (16) 4-5 Connection for instrumentation 1/2" Gas F
(17) (18) H12(15) 8 Lower heat exchanger inlet 1" Gas F
H11 (14)
9 Electrical immersion 1"1/2 Gas F
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H10 (12) (13) H9(11) 10 Upper heat exchanger outlet 1" Gas F
H8 (10) 11 Connection for instrumentation 1/2" Gas F
H
HYDRONIC
Domestic cold water circuit inlet 3/4” Gas M
20
H3 (4) (1” Gas M for models 120kW)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H1 (1)(2) 21
Domestic hot water circuit outlet 3/4” Gas M (1” Gas M for
models 120kW)
INERTIAL
TANKS
WATER PRESSURE
(19)
(4)(5)(10)
50° 50°
RECEIVERS
800 805 940 1840 2066 265 233 378 584 690 443 918 1003 1115 1115 1442 1347 1541
1000 946 940 2130 2328 265 233 384 656 787 443 1145 1188 1388 1309 1588 1661 1831
1500 1454 1100 2250 2504 313 281 432 736 845 491 1236 1286 1396 1377 1783 1673 1909
221
HYDRONIC
222
223
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
PLATE HEAT
EXCHANGER
Cordivari plate heat exchangers, are offering now an even more
complete range of solutions for domestic, residential and commercial
applications. A wide and flexible proposal, both for brazed exchangers
of small dimensions, or plate-to-plate exchangers for a greater
heat exchange. New range of exchangers, thanks to various
dimensions and types, to connections from DN32 to DN100, to
different and extended working pressure limits, allows to meet any
plant requirements or plumbing need. From small single-family house
sourced by boiler or pellet stove, to big plants, every installation finds
today the most suitable Cordivari solutions
thanks to the new on-line professional
dimensioning tool where you
can always find the best
performing solution
and the most
Economical as well.
224
EXTRA- BOLLY®
CALORIFIERS
NEW PHC INSPECTABLE PLATE HEAT EXCHANGERS
PHC heat exchangers are used in all domestic and industrial installations where a
fluid exchange is required.
They are suitable for D.H.W production, (instantaneous or with a storage tank),
for the heating of swimming pools using different energy sources ( traditional
BOLLYTERM®
gas boiler, biomass, solar thermal systems). PHC heat exchangers can also be
CALORIFIERS
applied in district heating installations, in heat recovery systems, for the hydraulic
separation of installations.
The new range offers 6 main models that combined with the variability of the
plates number, of the gaskets, of the working pressure limits allows to meet any
plant requirements or plumbing need.
STEEL
Being inspectable, the PHC exchangers are recommended for all plants where an
LE S STE
CALORIFIERS
efficient but flexible heat exchanger is required, allowing easily maintenance and
STAINLESS
STAINLES
cleaning.
PHC exchanger are designed for all applications stated on Art. 4.3 of the Pressure
Equipment Directive (P.E.D.) 2014/68/UE.
R FIERS FORR
HEAT PUMP
CALORIFIERS
ORI
CALLO
CYLINDERS - PUFFER
MULTIFUEL ENERGY
GY
NEW SLB BRAZED PLATE HEAT EXCHANGERS
New SLB Plate Heat Exchangers provide the most compact and economical solution in all
domestic and industrial installations where a heat exchange is required.
The technology is based on the joining by 99% pure copper brazing of multiple 316L
stainless steel plates.
The new range offers 4 main models available in insulated or not-insulated version designed
HYDRONIC
to satisfy all possible thermal exchange needs.
SLB Heat Exchangers are designed for D.H.W. production or for heating , refrigeration,
evaporation, industrial processing, cooling.
INERTIAL
TANKS
AT PRESSURE
TANKS
WATER
ON-LINE PLATE EXCHANGERS TOOL WA
W ED AIR
AIIRR
A PROFESSIONAL TOOL:
PA
SORI
SPARE
CCCEESO
http://www.cordivari.com/configurator_plate_exchangers
TE
T
225
PLATE HEAT EXCHANGERS
APPLICATION PHC exchangers are designed for the use stated on Art.
PHC Heat exchangers are used in domestic and 3.3 of PED 97/23/CE. In particular, they are intended
industrial installation. In particular they’re suitable to be used with non-dangerous liquids with steam
for production of D.H.W., as well as for heating of pressure at maximum operating temperature not
swimming pools using different energy sources exceeding 0.5 bar above normal atmospheric pressure.
(traditional boiler, solid fuel, solar thermal system). For Every Exchanger has serial number label and end-user
domestic application, the PHC are suitable for district manual.
heating installation.
CHEMICAL COMPATIBILITY
MATERIAL Material used for PHC Exchangers are suitable for
• Frame (not in contact with fluids) in painted mild steel following liquids:
• Guide for Heat exchanger plates, bolts and screw nuts • Water • WATER POOL • Milk • Whisky • Acetone •
(not in contact with fluids) in galvanized mild steel Glycole • Glycoled Water • Mineral Water • Wine • Wine
• Nipples and plates (in contact with fluid) in 316L Vinegar • Etanol • Etilenic Glycole• De-mineralized Water
Stainless Steel • Acetic Acid • Beer • Liquors• Methanol • Propylenic
• EPDM Gaskets. GlycoL
TECHNICAL DESCRIPTION
PHC exchangers are inspectionable plate to plate type.
Their shape ensures the possibility of opening the
exchanger for cleaning.
WORKING CONDITION The modular design allows you to change the
configuration of the exchanger even after a period of Gaskets Movable plate
Starting plate
231
226
EXCHANGERS PHC 4620 - DN32
EXTRA- BOLLY®
CALORIFIERS
S T O C K
grey AVAILABILITY
(PN16 VERSION ON REQUEST)
69
With EPDM gaskets With NBR gaskets S Fixing Primary Vol. =
BOLLYTERM®
L
CALORIFIERS
N° of PN16 PN16 quote Secondary Vol.
PN10 VERSION PN10 VERSION
1 3
plates VERSION VERSION
Art. Nr. Art. Nr. [mm] [mm] [lt ]
9 3175056654271 3175056654241 27 0,36
460
380
STAINLESS STEEL
2 4 17 3175056654275 3175056654245 51 0,72
CALORIFIERS
19 3175056654276 WITH 3175056654246 WITH 57 0,81
220
200 21 3175056654277 SURCHARGE 3175056654247 SURCHARGE 63 0,90
23 3175056654278 3175056654248 69 0,99
L
25 3175056654279 3175056654249 75 1,08
S 70 27 3175056654280 3175056654250 81 1,17
29 3175056654281 3175056654251 87 1,26
31 3175056654282 3175056654252 93 1,35
33 3175056654283 3175056654253 99 1,44
CALORIFIERS FOR
35 3175056654284 3175056654254 105 1,53
HEAT PUMP
37 3175056654285 3175056654255 111 1,62
39 3175056654286 3175056654256 117 1,71
41 3175056654287 3175056654257 123 1,80
43 3175056654288 3175056654258 129 1,89
45 3175056654289 3175056654259 135 1,98
47 3175056654290 3175056654260 141 2,07
49 3175056654291 WITH 3175056654261 WITH 147 2,16
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Connections 370
51 3175056654292 SURCHARGE 3175056654262 SURCHARGE 153 2,25
DN32 (1’’1/4) 53 3175056654293 3175056654263 159 2,34
Gas M 55 3175056654294 3175056654264 165 2,43
57 3175056654295 3175056654265 171 2,52
1 Primary Inlet 59 3175056654296 3175056654266 177 2,61
2 Primary Outlet 61 3175056654297 3175056654267 183 2,70
63 3175056654298 3175056654268 189 2,79
3 Secondary Outlet
65 3175056654299 3175056654269 195 2,88
4 Secondary Inlet 67 3175056654300 3175056654270 201 2,97
HYDRONIC
EXCHANGERS PHC 7420 - DN32 S T O C K
AVAILABILITY
grey
(PN16 VERSION ON REQUEST)
INERTIAL
TANKS
69 With EPDM gaskets With NBR gaskets S Fixing
L
Primary Vol. =
N° of PN16 PN16 quote Secondary Vol.
PN10 VERSION PN10 VERSION
1 3 plates VERSION VERSION
Art. Nr. Art. Nr. [mm] [mm] [lt ]
9 3175056654391 3175056654361 27 0,68
WATER PRESSURE
11 3175056654392 3175056654362 33 0,85
666
746
TANKS
15 3175056654394 3175056654364 45 1,19
17 3175056654395 3175056654365 51 1,36
2 4
19 3175056654396 WITH 3175056654366 WITH 57 220 1,53
21 3175056654397 SURCHARGE 3175056654367 SURCHARGE 63 1,70
200 23 3175056654398 3175056654368 69 1,87
25 3175056654399 3175056654369 75 2,04
COMPRESSED AIR
4 Secondary Inlet
SUPPORT
227
EXCHANGERS PHC 7431 - DN65
S T O C K
grey
AVAILABILITY
per versione pn16 Art. Nr. a richiesta)
228
EXCHANGERS PHC 8031 - DN50
EXTRA- BOLLY®
CALORIFIERS
S T O C K
grey
AVAILABILITY
(PN16 VERSION ON REQUEST)
BOLLYTERM®
CALORIFIERS
314 With EPDM gaskets With NBR gaskets S Fixing
L
Primary Vol. =
N° of PN16 PN16 quote Secondary Vol.
140 PN10 VERSION PN10 VERSION
plates VERSION VERSION
Art. Nr. Art. Nr. [mm] [mm] [lt ]
1 3
13 3175056654741 3175056654689 46 2,28
15 3175056654742 3175056654690 53 2,66
17 3175056654743 3175056654691 60 3,04
772.6
640
STAINLESS STEEL
19 3175056654744 3175056654692 67 3,42
405
CALORIFIERS
21 3175056654745 3175056654693 74 3,80
23 3175056654746 3175056654694 81 4,18
25 3175056654747 3175056654695 88 4,56
2 4 27 3175056654748 3175056654696 95 4,94
29 3175056654749 WITH 3175056654697 WITH 102 5,32
31 3175056654750 3175056654698 109 5,70
33 3175056654751 SURCHARGE 3175056654699 SURCHARGE 116 6,08
35 3175056654752 3175056654700 123 6,46
CALORIFIERS FOR
37 3175056654753 3175056654701 130 505 6,84
HEAT PUMP
39 3175056654754 3175056654702 137 7,22
41 3175056654755 3175056654703 144 7,60
L 43 3175056654756 3175056654704 151 7,98
S 45 3175056654757 3175056654705 158 8,36
47 3175056654758 3175056654706 165 8,74
49 3175056654759 3175056654707 172 9,12
51 3175056654760 3175056654708 179 9,50
CYLINDERS - PUFFER
MULTIFUEL ENERGY
53 3175056654761 3175056654709 186 9,88
55 3175056654762 3175056654710 193 10,26
605
57 3175056654763 3175056654711 200 10,64
59 3175056654764 3175056654712 207 11,02
61 3175056654765 3175056654713 214 11,40
63 3175056654766 3175056654714 221 11,78
65 3175056654767 3175056654715 228 12,16
67 3175056654768 3175056654716 235 12,54
69 3175056654769 3175056654717 242 12,92
71 3175056654770 3175056654718 249 13,30
HYDRONIC
73 3175056654771 3175056654719 256 13,68
75 3175056654772 3175056654720 263 14,06
77 3175056654773 3175056654721 270 14,44
Connections 79 3175056654774 3175056654722 277 14,82
81 3175056654775 WITH 3175056654723 WITH 284 15,20
DN50 (2”) 83 3175056654776 3175056654724 291 15,58
85 3175056654777 SURCHARGE 3175056654725 SURCHARGE 298 15,96
87 3175056654778 3175056654726 305 16,34
1 Primary Inlet 89 3175056654779 3175056654727 312 16,72
INERTIAL
TANKS
2 Primary Outlet 91 3175056654780 3175056654728 319 855 17,10
3 Secondary Outlet 93 3175056654781 3175056654729 326 17,48
4 Secondary Inlet 95 3175056654782 3175056654730 333 17,86
97 3175056654783 3175056654731 340 18,24
99 3175056654784 3175056654732 347 18,62
101 3175056654785 3175056654733 354 19,00
WATER PRESSURE
103 3175056654786 3175056654734 361 19,38
105 3175056654787 3175056654735 368 19,76
TANKS
107 3175056654788 3175056654736 375 20,14
109 3175056654789 3175056654737 382 20,52
111 3175056654790 3175056654738 389 20,90
113 3175056654791 3175056654739 396 21,28
115 3175056654792 3175056654740 403 21,66
COMPRESSED AIR
RECEIVERS
AND SPARE PARTS
ACCESORIES
TECHNICAL
SUPPORT
229
EXCHANGERS PHC 12046 - DN100
460
223 With EPDM gaskets With NBR gaskets S Fixing
L
Primary Vol. =
N° of PN16 PN16 quote Secondary Vol.
PN10 VERSION PN10 VERSION
plates VERSION VERSION
1 3 Art. Nr. Art. Nr. [mm] [mm] [lt ]
13 3175056654949 3175056654897 40 5,07
1197
230
EXTRA- BOLLY®
ON-LINE PLATE EXCHANGERS TOOL
CALORIFIERS
ON-LINE SOFTWARE TO SIZE THE CORDIVARI PLATE EXCHANGERS
BOLLYTERM®
CALORIFIERS
A professional
tool:
STAINLESS STEEL
CALORIFIERS
User friendly, fast
and for free
CALORIFIERS FOR
HEAT PUMP
CYLINDERS - PUFFER
MULTIFUEL ENERGY
www.cordivari.com/configurator_plate_exchangers
DO YOUR CORDIVARI PLATE EXCHANGER SIZING
HYDRONIC
Few clicks and you’ll get your tailored product everywhere and free
of charge. You can download your report, or save it on your log in
area at www.cordivari.com.
INERTIAL
TANKS
Try it now!
WATER PRESSURE
TANKS
MPRESSED AIR
RECEIVERS
COMPRESSED
CO
C OMP
AND SPARE PARTS
ACCESORIES
TECHNICAL CAL
SUPPORTORT
NIICA
SUUPPPPOR
TE HN
CCH
S
T
231
BRAZED PLATE EXCHANGERS SLB 15
TECHNICAL DESCRIPTION TECHNICAL CHARACTERISTIC :
New brazed Plate Exchangers SLB Cordivari, provides AISI 316 L Stainless steel brazed plate, braze-welded
the most compact and economical solution suitable for with 99,99% pure copper
many applications.
The SLB plate exchangers are designed for different
needs in heating, refrigeration, evaporation, industrial
processing, cooling.
WORKING CONDITION
MAIN ADVANTAGES:
- High Efficiency
- Long lasting Max pressure Max temperature
- Savings
- High reliability 10 bar 190 °C (*)
- Huge possibility to modify the relation between
storage volume and Heat exchange. (*) For temperature above 110°C, see techni-
cal support
S T O C K
grey
AVAILABILITY
A
E C
PERFORMANCE DATA( PRIMARY AND SECONDARY FLUID, WATER, PRESSURE LOSS < 50 KPA)
Primary Secondary Primary Secondary Primary Secondary
80/70 °C 60/70 °C 80/65 °C 60/70 °C 80/65 °C 55/70 °C
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
10 5 0,442 0,440 10 1,5 0,088 0,132 10 3 0,177 0,176
20 15 1,326 1,320 20 4 0,235 0,352 20 7 0,412 0,410
30 24 2,121 2,112 30 7 0,412 0,616 30 12 0,706 0,703
40 32 2,828 2,816 40 10 0,588 0,880 40 17 1,000 0,996
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
10 21 1,236 0,364 10 28 1,235 0,606 10 16 1,408 0,346
20 45 2,648 0,781 20 58 2,557 1,255 20 30 2,640 0,649
30 60 3,531 1,041 30 80 3,527 1,731 30 40 3,521 0,866
40 71 4,178 1,232 40 95 4,189 2,056 40 47 4,137 1,017
232
BRAZED PLATE EXCHANGERS SLB 20
EXTRA- BOLLY®
CALORIFIERS
TECHNICAL DESCRIPTION TECHNICAL CHARACTERISTIC :
New brazed Plate Exchangers SLB Cordivari, provides - AISI 316 L Stainless steel brazed plate, braze-welded
the most compact and economical solution suitable for with 99,99% pure copper
many applications. - High efficiency PPE insulation (INSULATED VERSION)
BOLLYTERM®
The SLB plate exchangers are designed for different
CALORIFIERS
needs in heating, refrigeration, evaporation, industrial
processing, cooling.
WORKING CONDITION
MAIN ADVANTAGES:
- High Efficiency
- Long lasting Max pressure Max temperature
- Savings
STAINLESS STEEL
- High reliability 10 bar 190 °C (*)
CALORIFIERS
- Huge possibility to modify the relation between
storage volume and Heat exchange. (*) For temperature above 110°C, see techni-
cal support
CALORIFIERS FOR
S T O C K
HEAT PUMP
grey
AVAILABILITY
A
E C
CYLINDERS - PUFFER
MULTIFUEL ENERGY
B D A 73 16 5250410010002 5250410011002 46 1,13
B 311 20 5250410010003 5250410011003 55 1,16
3,6 24 5250410010004 5250410011004 64 1,19
C 40
30 5250410010005 5250410011005 78 1,24
D 278 34 5250410010006 5250410011006 87 1,27
40 5250410010007 5250410011007 101 1,32
PERFORMANCE DATA( PRIMARY AND SECONDARY FLUID, WATER, PRESSURE LOSS < 50 KPA)
HYDRONIC
Primary Secondary Primary Secondary Primary Secondary
80/70 °C 60/70 °C 80/65 °C 60/70 °C 80/65 °C 55/70 °C
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
12 10 0,884 0,880 12 11 0,647 0,968 12 16 0,941 0,938
INERTIAL
TANKS
16 16 1,414 1,408 16 16 0,941 1,408 16 24 1,412 1,406
20 20 1,768 1,760 20 20 1,177 1,760 20 30 1,765 1,758
24 24 2,121 2,112 24 24 1,412 2,112 24 36 2,118 2,110
30 30 2,651 2,640 30 30 1,765 2,640 30 45 2,648 2,637
34 33 2,916 2,904 34 34 2,001 2,992 34 50 2,942 2,930
40 37 3,270 3,257 40 37 2,177 3,257 40 55 3,236 3,223
WATER PRESSURE
Primary Secondary Primary Secondary Primary Secondary
TANKS
80/65 °C 10/60 °C 80/60 °C 10/50 °C 70/60 °C 10/50 °C
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
COMPRESSED AIR
233
BRAZED PLATE EXCHANGERS SLB 30
TECHNICAL DESCRIPTION TECHNICAL CHARACTERISTIC :
New brazed Plate Exchangers SLB Cordivari, provides - AISI 316 L Stainless steel brazed plate, braze-welded
the most compact and economical solution suitable for with 99,99% pure copper
many applications. - High efficiency PPE insulation (INSULATED VERSION)
The SLB plate exchangers are designed for different
needs in heating, refrigeration, evaporation, industrial
processing, cooling.
WORKING CONDITION
MAIN ADVANTAGES:
- High Efficiency
- Long lasting Max pressure Max temperature
- Savings
- High reliability 10 bar 190 °C (*)
- Huge possibility to modify the relation between
storage volume and Heat exchange. (*) For temperature above 110°C, see techni-
cal support
S T O C K
grey
AVAILABILITY
A
E C
PERFORMANCE DATA( PRIMARY AND SECONDARY FLUID, WATER, PRESSURE LOSS < 50 KPA)
Primary Secondary Primary Secondary Primary Secondary
80/70 °C 60/70 °C 80/65 °C 60/70 °C 80/65 °C 55/70 °C
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
14 23 2,033 2,024 14 12 0,706 1,056 14 18 1,059 1,055
20 33 2,916 2,904 20 18 1,059 1,584 20 30 1,765 1,758
30 50 4,419 4,401 30 30 1,765 2,640 30 48 2,824 2,813
40 68 6,010 5,985 40 41 2,413 3,609 40 65 3,825 3,809
50 83 7,335 7,305 50 52 3,060 4,577 50 80 4,707 4,688
234
BRAZED PLATE EXCHANGERS SLB 40
EXTRA- BOLLY®
CALORIFIERS
TECHNICAL DESCRIPTION TECHNICAL CHARACTERISTIC :
New brazed Plate Exchangers SLB Cordivari, provides - AISI 316 L Stainless steel brazed plate, braze-welded
the most compact and economical solution suitable for with 99,99% pure copper
many applications. - High efficiency PPE insulation (INSULATED VERSION)
BOLLYTERM®
The SLB plate exchangers are designed for different
CALORIFIERS
needs in heating, refrigeration, evaporation, industrial
processing, cooling.
WORKING CONDITION
MAIN ADVANTAGES:
- High Efficiency
- Long lasting Max pressure Max temperature
- Savings
STAINLESS STEEL
- High reliability 10 bar 190 °C (*)
CALORIFIERS
- Huge possibility to modify the relation between
storage volume and Heat exchange. (*) For temperature above 110°C, see techni-
cal support
CALORIFIERS FOR
S T O C K
HEAT PUMP
grey
AVAILABILITY
A
E C
CYLINDERS - PUFFER
MULTIFUEL ENERGY
B D A 106 40 5250410010202 5250410011202 104 10,2
B 466 50 5250410010203 5250410011203 128 12,1
12,7 60 5250410010204 5250410011204 151 14
C 50
D 466
PERFORMANCE DATA( PRIMARY AND SECONDARY FLUID, WATER, PRESSURE LOSS < 50 KPA)
HYDRONIC
Primary Secondary Primary Secondary Primary Secondary
80/70 °C 60/70 °C 80/65 °C 60/70 °C 80/65 °C 55/70 °C
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
30 43 3,800 3,785 30 42 3,712 3,697 30 64 3,766 3,750
INERTIAL
TANKS
40 57 5,037 5,017 40 55 4,861 4,841 40 85 5,002 4,981
50 71 6,275 6,249 50 70 6,186 6,161 50 105 6,178 6,153
60 83 7,335 7,305 60 82 7,247 7,217 60 122 7,179 7,149
WATER PRESSURE
Primary Secondary Primary Secondary Primary Secondary
TANKS
80/65 °C 10/60 °C 80/60 °C 10/50 °C 70/60 °C 10/50 °C
Thermal output Primary Secondary Thermal output Primary Secondary Thermal output Primary Secondary
N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate N° of exchanged flow rate flow rate
plates plates plates
[kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h] [kW] [m3 /h] [m3/h]
COMPRESSED AIR
235
MACS® MODULE
MODULE FOR IMMEDIATE D.H.W. PRODUCTION
Primary
circuit inlet
MACS® module
Output Stainless steel Plate Exchanger 316 L
[kW] Art. Nr.
70 3316006700005
120 3316006700006
Primary cir-
cuit outlet
Accessories on request
Recirculation kit
The use of Cordivari’s recycling kit allows to manage on the system a link of the DHW
Art. Nr. recycling.
5221000000054 The benefit consists of improving the comfort for the user by reducing the waste of
domestic water and producing DHW immediately at the right temperature.
In particular, the Cordivari electronic recycling kit allows to:
• Maximize the energy saving by setting the program of recycling temperature based
on personal habits.
Control display + pump • Daily and weekly scheduling to manage until 8 time slots for each days of the week
(for D.H.W.) • Constantly monitoring the working and the efficiency of the recycle tanks to the
self-diagnostics of the system
• Work also without the temperature’s probe, through programmable temporary
actions.
236
MACS® MODULE
EXTRA- BOLLY®
CALORIFIERS
MODULE FOR IMMEDIATE D.H.W. PRODUCTION
M GENERATOR
B A
BOLLYTERM®
CALORIFIERS
N
I
L
STAINLESS STEEL
E
CALORIFIERS
G
D
C A Domestic Hot Water exit G “Energy Saving” Circulation Pump
H B Domestic Water entry H Thermostatic Valve
CALORIFIERS FOR
HEAT PUMP
D Control for thermostatic head J Flow switch for DHW
O
E Heating water inlet from the buffer K Return to primary circuit
I F Heating water back to the buffer L Purge valve
CYLINDERS - PUFFER
MULTIFUEL ENERGY
N Recirculation pump (optional)
O D.H.W. recirculation control display (optional)
HYDRONIC
80 60
70
50
60
D.H.W. Flow Rate. [lt/min]
40
INERTIAL
120 Kw
TANKS
50
80/25-10
40 30 80/20-10
30 70/25-10
20 70/20-10
WATER PRESSURE
20 60/25/10
50/25-10
60/20/10
10 50/20-10
TANKS
10
0 0
40 45 50 55 60 40 45 50 55 60
60
40
50 35
30
40
D.H.W. Flow Rate. [lt/min]
25
ACCESORIES
30
70 Kw
20
80/25-10
20 15
70/25-10 80/20-10
10 10
60/25/10 70/20-10
50/25-10 5
TECHNICAL
60/20/10
SUPPORT
0 50/20-10
40 45 50 55 60
0
40 45 50 55 60
237
ELECTRONIC MACS® MODULE
MODULE FOR IMMEDIATE D.H.W. PRODUCTION WITH ELECTRONIC CONTROL UNIT
APPLICATION The immediate and fast production of D.H.W. granted by the external
MACS® module produces instantly D.H.W. with high flow rate. plate exchanger system allow the following benefits:
- reduced dimensions for DHW productions
EXCHANGER, MATERIAL - easy maintenance
Copper primary pipes, 316L stainless steel DHW sanitary circuit; - maximum hygiene for anti-legionellosis bacteria’s
brass fittings and valve. - to produce more DHW than the quantity obtained by water heater
316L stainless steel brazed plate heat exchanger. with similar capacity thanks to the heating water stored at an higher
PPE module case housing and insulating the exchangers circuits. temperature than DHW.
Primary
circuit outlet
Accessories on request
Art. Nr. The recirculation kit for Electronic MACS® module allows the implementation of a
5221000000073 sanitary recirculation ring on the system where modules are installed.
The main advantage of such sanitary recirculation ring is to improve comfort and spe-
ed in achieving and enjoying the desired DHW temperature, reducing energy waste.
The control unit included as standard with electronic MACS® modules allow the com-
D.H.W. recirculation kit plete management
of all settings of the recirculation ring, such as temperature, setting etc…
238
ELECTRONIC MACS® MODULE
EXTRA- BOLLY®
CALORIFIERS
MODULE FOR IMMEDIATE D.H.W. PRODUCTION WITH ELECTRONIC CONTROL UNIT
B A
GENERATOR
BOLLYTERM®
CALORIFIERS
L
D M
E
G C
STAINLESS STEEL
H
CALORIFIERS
A Domestic hot water outlet (DHW) F Primary Outlet
B Domestic Water entry G “Energy Saving” Circulation Pump
CALORIFIERS FOR
HEAT PUMP
I D Flow rate/ temperature probe I Electronic control unit
E Primary Inlet
CYLINDERS - PUFFER
F
MULTIFUEL ENERGY
M D.H.W. recirculation pump (optional)
HYDRONIC
80 60
70
50
60
D.H.W. Flow Rate. [lt/min]
40
INERTIAL
120 Kw
TANKS
50
80/25-10
40 30 80/20-10
30 70/25-10
20 70/20-10
WATER PRESSURE
20 60/25/10
50/25-10
60/20/10
10 50/20-10
TANKS
10
0 0
40 45 50 55 60 40 45 50 55 60
60
40
50 35
30
40
D.H.W. Flow Rate. [lt/min]
25
ACCESORIES
30
70 Kw
20
80/25-10
20 15
70/25-10 80/20-10
10 10
60/25/10 70/20-10
50/25-10 5
TECHNICAL
60/20/10
SUPPORT
0 50/20-10
40 45 50 55 60
0
40 45 50 55 60
239
CASCADE MACS® SYSTEM
CASCADE MACS® SYSTEM WITH ELECTRONIC CONTROL UNIT FOR INSTANTANEOUS DHW PRODUCTION ON BIG INSTALLATION
240
CASCADE MACS® SYSTEM
EXTRA- BOLLY®
CALORIFIERS
CASCADE MACS® SYSTEM WITH ELECTRONIC CONTROL UNIT FOR INSTANTANEOUS DHW PRODUCTION ON BIG INSTALLATION
BOLLYTERM®
CALORIFIERS
DOMESTIC The system includes:
WATER ENTRY
MACS® module - 120 kW
STAINLESS STEEL
CALORIFIERS
DOMESTIC
HOT WATER EXIT
PRIMARY CIRCUIT
x2
ENTRY
CALORIFIERS FOR
HEAT PUMP
2-ways valve - 1”
CYLINDERS - PUFFER
MULTIFUEL ENERGY
PRIMARY CIRCUIT EXIT
x1
HYDRONIC
INERTIAL
TANKS
WITH 3 MACS® MODULES
WATER PRESSURE
MACS® module - 120 kW
TANKS
DOMESTIC
DOMESTIC WATER ENTRY
HOT WATER EXIT
PRIMARY CIRCUIT
COMPRESSED AIR
ENTRY
RECEIVERS
x3
2-ways valve - 1”
AND SPARE PARTS
ACCESORIES
241
PRS MODULE
MODULE FOR IMMEDIATE DHW PREPARATION
APPLICATION
A calcareous deposits inside.
P modules are used for immediate (without storage)
PRS • Electronic panel with PLC. PLC has a software specially
Domestic Hot Water production or semi-immediate (with
D designed to manage the PRS with anti-legionellosis cycles
sstorage) in case of bigger systems, aside from the primary recording option.
ccircuit energy source. PRS modules are equipped with a • Temperature probes.
ssophisticate management system able to automatically • Galvanized mild steel frame.
ccontrol several installations and punctually manage anti- WORKING CONDITION
llegionellosis cycles, recording data and their results. Max pressure = 10 bar
COMPONENTS
C Max temperature = 140°C (meant as max gaskets operating
• Inspection plate heat exchanger. The exchanger can be temperature that has always to be the lowest among the
opened for a better cleaning in order to keep high hygiene temperatures and is equal to steam tension of 0.5 bar more
conditions. than the normal atmosphere pressure considered for two
• Primary circuit single or double pump. The double pump circulating fluids).
is suitable for systems that need to be always operating. In case of application at temperature higher than 110°C see
In case of breakdown, the system automatically starts the TECHNICAL SUPPORT & REGULATIONS section.
second pump and guarantees heating for DHW production. WARRANTY
• Motor-operated mixing valve. The valve mixes the primary 2 years - See general sales conditions and warranty.
fluid passing by the heat plate exchanger, so that the
temperature does not go up too much and it reduces the
Exchanger H L P H1 H2 H3 L P
N° of plates
model [mm]
9
11
13
15
17
19 530
21 (4)
25 H (2) H2(2) (4)
PHC 4620 27 1050 380 520
29
H1(1)
31
(1)
33
35
250 140
39 (3) H3
680
41
43 (3)
45
17
19
23 530 (1) 1 Primary Inlet
25
PHC 7420 29 1330 660 800 (2) 2 Primary Outlet
35 3 Domestic Hot Water entry
37
680 4 Domestic Hot Water exit
39
43 (3)(4)
242
PRS MODULE
EXTRA- BOLLY®
CALORIFIERS
MODULE FOR IMMEDIATE DHW PREPARATION
The following schemes are purely illustrative.
To realize the installation, always refer to a
EXAMPLE OF INSTALLATION WITH A DHW STORAGE TANK qualified design engineer.
BOLLYTERM®
CALORIFIERS
7
C
B
STAINLESS STEEL
CALORIFIERS
D
3
1
1 Generator
5
2 Expansion vessel
CALORIFIERS FOR
HEAT PUMP
6 3 Circulation group
9
4 Hydraulic safety group
5 PRS module
6 Collector/Catcher
2 3 3 3 7 PUFFER (Inertial tank)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
8 Safety Valve
4 8 9 Heat exchanger
A Domestic cold water circuit inlet
A B Domestic hot water users
C To the heating system
D Recirculation
E
E Drain
HYDRONIC
The following schemes are purely illustrative.
To realize the installation, always refer to a
EXAMPLE OF INSTALLATION WITHOUT A WATER STORAGE TANK qualified design engineer.
INERTIAL
TANKS
7
C
B
WATER PRESSURE
TANKS
D
3
1
1 Generator
5
2 Expansion vessel
COMPRESSED AIR
3 Circulation group
RECEIVERS
8 Safety Valve
2 3
ACCESORIES
9 Heat exchanger
4 8 A Domestic cold water circuit inlet
B Domestic hot water users
243
PRS MODULE
MODULE FOR IMMEDIATE DHW PREPARATION
244
PRS MODULE
EXTRA- BOLLY®
CALORIFIERS
MODULE FOR IMMEDIATE DHW PREPARATION
BOLLYTERM®
Primary 50/40 °C
WITH SINGLE PUMP
CALORIFIERS
Secondary 10/45 °C
DHW
N° of Output Flow rate Flow Over dimensioning
Exchanger model Art. Nr. Rate
plates factor
[kW] [m3/h] [m3/h]
9 3435316701029 15 1,32 0,38 0,01
STAINLESS STEEL
11 3435316701030 20 1,76 0,50 0,02
CALORIFIERS
13 3435316701031 26 2,29 0,65 0,01
15 3435316701032 32 2,81 0,80 0,01
17 3435316701033 37 3,25 0,93 0,01
19 3435316701034 43 3,78 1,08 0,01
21 3435316701035 49 4,31 1,23 0,01
25 3435316701036 60 5,28 1,51 0,01
CALORIFIERS FOR
PHC 4620 27 3435316701037 66 5,81 1,66 0,01
HEAT PUMP
29 3435316701038 72 6,33 1,81 0,01
31 3435316701039 77 6,77 1,94 0,01
33 3435316701040 83 7,30 2,09 0,01
35 3435316701041 89 7,83 2,24 0,01
39 3435316701042 100 8,80 2,51 0,01
41 3435316701043 106 9,32 2,66 0,01
CYLINDERS - PUFFER
MULTIFUEL ENERGY
43 3435316701044 112 9,85 2,81 0,01
45 3435316701045 118 10,38 2,97 0,01
17 3435316701046 56 4,93 1,41 0,80
19 3435316701047 64 5,63 1,61 0,78
23 3435316701048 78 6,86 1,96 0,80
25 3435316701049 85 7,48 2,14 0,81
29 3435316701050 99 8,71 2,49 0,82
35 3435316701025 120 10,56 3,02 0,84
37 3435316701026 128 11,26 3,22 0,84
HYDRONIC
PHC 7420
39 3435316701027 135 11,88 3,39 0,84
43 3435316701028 149 13,11 3,74 0,85
PRS modules with the highest over dimensioning factor are offered to extend the circulating lifecycle and keep the exchanger cleaner, so to have higher efficiency and
reducing the maintenance frequency.
Primary 50/40 °C
WITH DOUBLE PUMP
INERTIAL
Secondary 10/45 °C
TANKS
DHW
N° of Output Flow rate Flow Over dimensioning
Exchanger model Art. Nr. Rate
plates factor
[kW] [m3/h] [m3/h]
9 3435316701051 15 1,32 0,38 0,01
WATER PRESSURE
11 3435316701052 20 1,76 0,50 0,02
13 3435316701053 26 2,29 0,65 0,01
TANKS
15 3435316701054 32 2,81 0,80 0,01
17 3435316701077 37 3,25 0,93 0,01
19 3435316701078 43 3,78 1,08 0,01
21 3435316701079 49 4,31 1,23 0,01
25 3435316701080 60 5,28 1,51 0,01
COMPRESSED AIR
PHC 7420
39 3435316701075 135 11,88 3,39 0,84
43 3435316701076 149 13,11 3,74 0,85
PRS modules with the highest over dimensioning factor are offered to extend the circulating lifecycle and keep the exchanger cleaner, so to have higher efficiency and
reducing the maintenance frequency.
245
PRS MODULE
MODULE FOR IMMEDIATE DHW PREPARATION
Applications in
accomodation
facilities H OT E L R O O M
S
M IN IM U M
C A PAC IT Y O F
VA SO IN ER ZI A
LE
( STO RAG E AT
60°C)
Applications in
residential facilities
N° OF APARTMENTS (1 bathroom)
plates
plates
plates
plates
plates
246
PRS MODULE
EXTRA- BOLLY®
CALORIFIERS
MODULE FOR IMMEDIATE DHW PREPARATION
BOLLYTERM®
The graphics represent a useful guide to help choosing the suitable PRS module The applications imply the coupling of the PRS module with VASO INERZIALE for
CALORIFIERS
according to all possible exigencies of application. the accumulation of DHW.
The most common cases are showed such as applications in accommodation According to the size of the installation we indicate the most suitable PRS module
facilities or residential facilities. at the minimum thermal power supplied by the generator
PUFFER
300 PUFFER
PUFFER
Applications in 500
500
PUFFER
PUFFER PUFFER
600
accomodation
STAINLESS STEEL
1000 1000
CALORIFIERS
facilities
plates
CALORIFIERS FOR
HEAT PUMP
plates
HOTEL ROOMS
plates
PRS module suggested
(10 °C - 45 °C)
plates
CYLINDERS - PUFFER
MULTIFUEL ENERGY
plates
plates
Minimum power of the generator
(primary temp. 70°C)
Rooms n°
PUFFER temperature 65 °C
HYDRONIC
PUFFER PUFFER
500 PUFFER PUFFER
600 PUFFER
Applications in 750 750 800
PUFFER PUFFER PUFFER PUFFER
INERTIAL
1000 PUFFER
residential facilities
TANKS
1000 1000 PUFFER 1500
1000 1500
plates
WATER PRESSURE
plates
TANKS
N° OF APARTMENTS (1 bathroom)
plates
plates
plates
plates
plates
COMPRESSED AIR
plates
RECEIVERS
plates
PRS module suggested
(10 °C - 45 °C) plates
plates
N° of apartments (1
bathroom)
PUFFER temperature 65 °C
TECHNICAL
SUPPORT
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
247
RAPID HEAT EXCHANGER
External
Height H 1-2 3-4 5
Model exchange diameter
[mm] [mm] Connections
24000 320 1” 1/2 1/2” 3/8”
35000 175 425 1” 1/2 1/2” 3/8”
45000 525 1” 1/2 1/2” 3/8”
1 Primary Inlet
2 Primary Outlet
3 Secondary Inlet
4 Secondary Outlet
5 Air purge
248
OPEN EXPANSION VESSEL
EXTRA- BOLLY®
CALORIFIERS
304 STAINLESS STEEL / GALVANIZED / POLYETHILENE
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
Opened Expansion tanks are used as safety accessories in the heating systems Expansion volume needed in the system is calculated by the following formula:
where, due to legal reason it is forbidden to install closed expansion tanks “Ve = C x e”
systems. In Italy, for the water fireplaces, they are still one of the most simple Where C is the water contained into the system and “e” is equal to the difference
and economic solution. Expansion tank is composed by a cover unit where all between the expansion factor of the water at the minimum conceivable
the security piping of outlet pipe for too full , supplying and systems charge , temperature with sleeping system and the expansion factor of the water at
should arrive. Its rule is to merge the water in excess due caused by temperature boiling temperature of atmospheric pressure. Considering the first water
increase. Expansion Tank should be placed on the highest point reached by the temperature equal to 10°C and the boiling one at 100°C
CYLINDERS - PUFFER
MULTIFUEL ENERGY
water and should have an expanding volume not less than the expansion volume “e” = 0.0431
developed by all the water contained into the system , whose value should be It is possible to connect more than one tank together.
declared in the project.
S T O C K
grey
AVAILABILITY
HYDRONIC
EXPANSION VESSEL INOX
Dimension
304 Stainless steel Expansion volume
Model HxLxP
Art. Nr. [mm] [litres]
304 Stainless steel 30 3941014010001 275x455x245 7,5
INERTIAL
TANKS
50 3941014010002 276x455x430 30
WATER PRESSURE
EXPANSION VESSEL Z
Dimension
TANKS
Galvanized Expansion volume
Model HxLxP
Art. Nr. [mm] [litres]
Galvanized 30 3941164010001 275x455x245 7,5
50 3941164010002 276x455x430 30
COMPRESSED AIR
RECEIVERS
Security hole Ø 30
Too full /purge 1” F
TECHNICAL
Floating ½” F
SUPPORT
System Inlet 1” F
249
R-Mix DN25 MODULES
CIRCULATION AND MIXED PUMPS MODULES FOR CENTRAL HEATING INSTALLATION
200
R-MIX DN25
380
MIXED UNIT
3435316700022
(20-45 °C)
MIXED UNIT
3435316700023
(45-70 °C)
125 50
250
Max
Pump Head Max Output
Model Connections flow rate Kvs
[mH2O] [kW] [l/h]
Unmixed Unit 1” 6 50 2150 8.0
With mixing valve 20-45°C 1” 7.5 35 1500 3.3
With mixing valve 45-70°C 1” 7.5 35 1500 3.3
Accessories on request
Wall fixing kit for Distributor for 2 x DN25 Distributor for 3 x DN25
Wall fixing kit for module Adapter connection kit
distribution headers pump units pump units
Art. Nr. 5221000000074 Art. Nr. 5221000000077 Art. Nr. 5221000000078 Art. Nr. 5221000000075 Art. Nr. 5221000000076
250
R-Mix DN32 MODULES
EXTRA- BOLLY®
CALORIFIERS
CIRCULATION AND MIXED PUMPS MODULES FOR CENTRAL HEATING INSTALLATION
BOLLYTERM®
CALORIFIERS
mixing valve with electronic control for the constant temperature
MATERIAL allows the maximum reliability in both Heating and Cooling.
Circuitry, fittings and valves in brass material The motorized Module DN32 can vary the opening of the mixing
Case in PPE, for protecting and insulating the module valve in order to maintain the inlet water temperature constant
Material used for components and accessories suitable for allowing the prompt and balanced reaction of the mixer module.
drinkable water according DM 174 dated 06.04.04 and Sect. 9 D.l.
31/2001. WARRANTY
2 years warranty (1 year for electronic components)
STAINLESS STEEL
TECHNICAL INFORMATIONS See general conditions for sales and warranty terms.
CALORIFIERS
R-Mix module are modules designed for the circulation of heating
water in closed central heating installations.
The Mixed Unit version meets all the installation needs with specific
models: middle and low temperature heating systems, need of
energy metering, cooling systems; everything with the possibility of
a management control by means of climatic controllers even built-
CALORIFIERS FOR
HEAT PUMP
200
R-MIX DN32
CYLINDERS - PUFFER
MULTIFUEL ENERGY
UNMIXED UNIT 3435316700024
372
380
NOTE
For motorized mixed unit version please always specify Fixed limit
Servomotor (see accessories below)
HYDRONIC
125 50
250
INERTIAL
TANKS
WATER PRESSURE
TANKS
UNMIXED MOTORIZED
UNIT MIXED UNIT
COMPRESSED AIR
RECEIVERS
Max
Pump Head Max Output
Model Connections flow rate Kvs
[mH2O] [kW] [l/h]
Unmixed Unit 1” ¼ 1÷8 111 4800 21
With motorized mixing valve 1” ¼ 1÷8 76 4400 16
AND SPARE PARTS
ACCESORIES
Accessories on request
TECHNICAL
SUPPORT
Distributor for 2 x DN32 Distributor for 3 x DN32 Wall fixing kit for
Fixed limit Servomotor Wall fixing kit for module
pump units pump units distribution headers
Art. Nr. 5221000000079 Art. Nr. 5221000000080 Art. Nr. 5221000000081 Art. Nr. 5221000000082 Art. Nr. 5221000000083
251
252
253
AND
CYLINDERS
INERTIAL TANKS
WATER PRESSURIZED
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
ACQUA REFRIGERATA INOX
VERTICAL AISI 304 STAINLESS STEEL CHILLED WATER TANK
PRESSURE TEMPERATURE
Pmax Tmax
6 bar -10 / +60 °C
ACQ. REF. XC 20 VT
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Df
(20 mm Not self-estinguishing
(2) Model insulation)
Art. Nr.
100 3001012500001
200 3001012500002
H4 (3)
(7) (4) 300 3001012500003
500 3001012500004
800 3001012500005
H3 (8)
1000 3001012500006
A
1 Drain
H2 (5) 2 Safety Valve
(6)
3-4
To the System
5- 6
254
HANGING VOLANO TERMICO PDC
EXTRA- BOLLY®
CALORIFIERS
HANGING ENERGY BUFFER FOR HEAT PUMP
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
PRESSURE TEMPERATURE
Pmax Tmax
4 bar -10 / +95 °C
CALORIFIERS FOR
HEAT PUMP
TECHNICAL DESCRIPTION MATERIAL
Buffers either for hot or cold water have two main functions: they work both as Mild steel
water divisor and energy buffer. EXTERNAL LINING
The water divisor makes the heat pump flow rates and terminals flow rates PVC plastic grey.
unconnected. The energy buffer function reduces the heat pump starting. INSULATION
Hanging energy buffers are designed for wall installation. High thermal insulation with ecological polyurethane hard foam.
CYLINDERS - PUFFER
MULTIFUEL ENERGY
WARRANTY
2 years
See general sales conditions and warranty.
De
(1)
ENERGY
VOLANO TERMICO PDC (12 unit box) EFFICIENCY
HYDRONIC
CLASS
S T O C K 12 unit box
AVAILABILITY Model ErP
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
grey
(3) (5) Art. Nr.
12 307016092000412 B
INERTIAL
TANKS
ENERGY
VOLANO TERMICO PDC EFFICIENCY
CLASS
H
I
Model ErP
Art. Nr.
WATER PRESSURE
25 3070160920001 C
50 3070160920003 C
TANKS
(4) (6)
1 Safety Valve
2 Drain
COMPRESSED AIR
(2)
AND SPARE PARTS
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
ACCESORIES
255
VOLANO TERMICO PDC
ENERGY BUFFER FOR HEAT PUMP
PRESSURE TEMPERATURE
Pmax Tmax
4 bar -10 / +95 °C
ENERGY
VOLANO TERMICO PDC EFFICIENCY
CLASS
De
ENERGY BUFFER FOR HEAT
Df Model PUMP ErP
Art. Nr.
(10)
100 3001162311001 C
S T O C K
200 3001162311002 C
AVAILABILITY
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
grey
300 3001162311003 C
500 3001162311014 C
H6 (7) (8) (9)
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
Cordivari LAB are certified conforming ASK ALWAYS FOR
www.cordivari.com/erp to European standard EN 15332, as CERTIFIED LABORATORIES
indicated by Ecodesign ErP Directive. DATA RESULTS
On line ErP label tool
256
VOLANO TERMICO PDC REVERSO
EXTRA- BOLLY®
CALORIFIERS
HEATING WATER STORAGE BOTH FOR HOT AND COLD WATER INSTALLATIONS
BOLLYTERM®
CALORIFIERS
hot heating water at high flow rate. Thanks to the aluminium lining ( removable so to ease the installation)
external lining it is suitable for outdoor installation. EXTERNAL LINING
MATERIAL Galvanized and painted metallic cover
Mild steel CONNECTION FOR ELECTRICAL IMMERSION HEATER
APPLICATION 1’’1/2 conncetion for low temperature electrical immersion heater
Buffer either for hot or cold water (thermostat from 0 to +50 °C) - see the table below.
ANTI-CORROSION TREATMENT WARRANTY
STAINLESS STEEL
The anti-corrosion treatment is not necessary being installed in 2 years
CALORIFIERS
closed systems. See general sales conditions and warranty.
CALORIFIERS FOR
HEAT PUMP
PRESSURE TEMPERATURE
Pmax Tmax
4 bar -10 / +90 °C
CYLINDERS - PUFFER
MULTIFUEL ENERGY
De
Df
(9)
HYDRONIC
H5 (6)(7)(8) VOLANO TERMICO PDC
H4 (5) HARD FOAM
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Model insulation
A
Art. Nr.
2500 3001162310559
H
INERTIAL
4000 3001162310561
TANKS
H2 (2)(3)
1 Drain
H1 (1)
WATER PRESSURE
2
3
To the System
TANKS
6
8
(9) 5
(2)(6) (3)(8) Connection for instrumentation 1/2” F
RECEIVERS
7
(1)
9 To the System
DAL 2500 to
from AL5000
5000 LT.
AND SPARE PARTS
(4)(5)(7)
ACCESORIES
3000 432 2988 1400 1540 2378 2760 127 711 998 1448 1785 1" DN150 PN16 2"
4000 494 3914 1600 1740 2386 2873 105 719 996 1426 1763 1" DN150 PN16 2"
257
VOLANO TERMICO CALDO-FREDDO R/C GB VT
VERTICAL INERTIAL HOT/COLD WATER TANK BOX
PRESSURE TEMPERATURE
Pmax Tmax
Suitable for outside installation
6 bar -10 / +90 °C
ENERGY EFFICIEN-
De VOLANO TERMICO CALDO-FREDDO CY CLASS
Model ErP
(2) Art. Nr.
S T O C K 100 3001162310501 C
grey
AVAILABILITY 200 3001162310502 C
300 3001162310503 C
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H4 (3) (7) (4) 500 3001162310524 C
800 3001162310525 C
H3 (8) 1000 3001162310526 C
1500 3001162310527 C
2000 3001162310528 C
A
1 Drain
2 Safety Valve
3-4-5-6 To the System
H2 (5) (6)
Connection for
7-8
Instrumentation 1/2” Gas F
H1 (1)
T Ü V R h e i n l a n d Energie
und Umwelt GmbH states
that test procedures and
www.cordivari.com/erp Cordivari LAB are certified conforming
to European standard EN 15332, as ASK ALWAYS FOR
indicated by Ecodesign ErP Directive. CERTIFIED LABORATORIES
On line ErP label tool DATA RESULTS
258
ACQUA REFRIGERATA ZINCATO ZB VT
EXTRA- BOLLY®
CALORIFIERS
VERTICAL GALVANIZED CHILLED WATER TANK
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
PRESSURE TEMPERATURE
Pmax Tmax
6 bar -10 / +60 °C
Suitable for outside installation
CALORIFIERS FOR
Storage of chilled water for Air Conditioning installations. These tanks are galvanized inside and outside, with immersion
HEAT PUMP
These buffer are with hard box insulation and an external lining with a galvanized in a pool of fused zinc with pureness not below 99,99%
and painted plate. (Uni EN 1179).
They are used for air conditioning installations in order to increase the thermal INSULATION
inertia and, for those installations without a low water-capacity, avoiding that the High thermal insulation with ecological hard polyurethane foam.
chilling generator is continually working. WARRANTY
EXTERNAL LINING 2 years
Galvanized and painted metallic cover. See general sales conditions and warranty.
CYLINDERS - PUFFER
MULTIFUEL ENERGY
De
HYDRONIC
ACQ. REF. ZB VT
(2)
Model (BOX INSULATION)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
Art. Nr.
100 3001162310001
200 3001162310002 H4 (3) (7) (4)
300 3001162310003
INERTIAL
500 3001162310004
TANKS
800 3001162310005 H3 (8)
1000 3001162310006
S T O C K
1500 3001162310007 AVAILABILITY
grey
2000 3001162310008
A
WATER PRESSURE
H
TANKS
SUITABLE FOR OUTSIDE INSTALLATION
1 Drain
2 Safety Valve
COMPRESSED AIR
H2 (5) (6)
RECEIVERS
800 147 788 810 2108 2119 108 458 1458 1758 1"1/4 3" 1/2"
SUPPORT
1000 170 1034 930 2162 2178 96 479 1479 1779 1"1/2 3" 1/2"
1500 183 1432 1010 2351 2386 102 471 1681 1981 2" 3" 1/2"
2000 219 1970 1170 2421 2437 102 506 1716 2016 2" 3" 1/2"
259
ACQUA REFRIGERATA GREZZO GC 20 VT
VERTICAL CHILLED NOT TREATED WATER TANK
PRESSURE TEMPERATURE
Pmax Tmax
6 bar -10 / +90 °C
S T O C K
grey
AVAILABILITY
Df
1 Drain
(2) ACQ. REF. GC 20 VT
2 Safety Valve (20 mm Not self-stinguishing
3456 To the System Model insulation)
Connection for instrumentation Art. Nr.
7-8
1/2” Gas F
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
H4 (3) 100 3001162131101
(7) (4) 200 3001162131102
INTERNAL BULKHEADS 300 3001162131103
VERSION AVAILABLE ON
H3 (8) 500 3001162131104
REQUEST
800 3001162131105
1000 3001162131106
1500 3001162131107
A
2000 3001162131108
H
2500 3001162131113
3000 3001162131109
INTERNAL 4000 3001162131110
BULKHEADS
5000 3001162131112
260
ACQUA REFRIGERATA GREZZO GC 20 OR
EXTRA- BOLLY®
CALORIFIERS
VERTICAL CHILLED NOT TREATED WATER TANK
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
PRESSURE TEMPERATURE
Pmax Tmax
6 bar -10 / +90 °C
CALORIFIERS FOR
APPLICATION AND TECHNICAL DESCRIPTION INSULATION
HEAT PUMP
Storage of chilled or hot water for inverter installations. – From 100 to 5000 liters: 20 mm fixed polyethylene not subject to condensation.
Vertical inertial water tanks are used for inverter systems in order to increase the Not self-estinguishing version. Not removable from the tank.
thermal inertia and, for those installations with a low water-capacity, avoiding – From 3000 to 5000 liters (increased insulation): 20 mm fixed polyethylene
that the chilling generator is continually working. not subject to condensation joined with NOFIRE® 50 mm soft polyester
MATERIAL fleece 100% made of recyclable material, with high Thermal insulation. Fire
Storage of chilled or hot water for inverter installations. resistance class B-s2d0 according to EN 13501.
EXTERNAL LINING WARRANTY
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Blue PVC with plastic black caps for connections. 2 years
See general sales conditions and warranty.
1 Drain
ACQ. REF. GC 20 OR 2 Safety Valve
(with 20 mm not self-estinguishing
HYDRONIC
Model insulation) 3-4
To the System
5- 6
Art. Nr.
7
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
INERTIAL
800 3001161031005 0 L1 (4) (7) (3) L2 (6) (5)
TANKS
1000 3001161031006
H3
1500 3001161031007
2000 3001161031008
2500 3001161031013
WATER PRESSURE
3000 3001161031009
H2 (1) (7)
Df
TANKS
5000 3001161031012
H1 (4) (6)
0
COMPRESSED AIR
RECEIVERS
L3 L4 (8) L5
L
100 32 99 400 934 215 720 290 415 645 63 293 523 1"1/4 1"1/2 1/2"
200 53 187 450 1339 230 1110 335 480 1005 61 316 571 1"1/4 1"1/2 1/2"
300 68 288 550 1389 275 1115 365 525 1025 115 425 760 1"1/4 2" 1/2"
500 102 496 650 1689 320 1370 415 570 1275 107 472 857 1"1/4 3" 1/2"
800 148 788 750 2000 350 1650 480 650 1520 101 516 951 1"1/4 3" 1/2"
1000 170 1034 850 2066 383 1683 513 683 1553 96 561 1046 1"1/2 3" 1/2"
1500 184 1432 950 2250 370 1880 505 670 1745 82 597 1142 2" 3" 1/2"
TECHNICAL
2000 220 1970 1100 2320 405 1915 525 705 1795 73 663 1283 2" 3" 1/2"
SUPPORT
2500 284 2300 1250 2140 470 1670 620 770 1520 154 829 1524 2" 4" 1/2"
3000 330 2908 1250 2640 470 2170 620 870 2020 154 829 1524 2" 4" 1/2"
4000 452 3749 1400 2730 515 2215 665 915 2065 142 892 1662 2" 4" 1/2"
5000 574 4964 1600 2790 545 2245 695 945 2095 125 975 1845 2" 4" 1/2"
261
ACQUA REFRIGERATA ZINCATO ZC 20 VT
VERTICAL GALVANIZED CHILLED WATER TANK
PRESSURE TEMPERATURE
Pmax Tmax
6 bar -10 / +60 °C
Df
ACQ. REF. ZC 20 VT
(2) (20 mm Not self-estinguishing
Model insulation)
Art. Nr.
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
100 3001162130001
H4 (3)
200 3001162130002
(7) (4)
300 3001162130003
500 3001162130004
H3 (8) 800 3001162130005
1000 3001162130006
1500 3001162130107
A
2000 3001162130108
H
2500 3001162130113
3000 3001162130109
4000 3001162130110
5000 3001162130112
H2 (5) 1 Drain
(6) 2 Safety Valve
3-4
To the System
5- 6
H1 (1)
0 7-8 Connection for instrumentation 1/2” Gas F
262
ACQUA REFRIGERATA ZINCATO ZC 20 OR
EXTRA- BOLLY®
CALORIFIERS
HORIZONTAL GALVANIZED CHILLED WATER TANK
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
PRESSURE TEMPERATURE
Pmax Tmax
6 bar -10 / +60 °C
CALORIFIERS FOR
HEAT PUMP
APPLICATION AND TECHNICAL DESCRIPTION MATERIAL
Storage of chilled water for air conditionig systems. These tanks are galvanized inside and outside, with immersion
Vertical chilled water tanks are used for air conditioning installations in order in a pool of fused zinc with pureness not below 99,99%
to increase the thermal inertia and, for those installations with a low water- (Uni EN 1179).
capacity, avoiding that the chilling generator is continually working. These tanks INSULATION
are made in galvanized mild steel. 20 mm fixed polyethylene not subject to condensation. Not self-extinguishing
EXTERNAL LINING version. Not removable from the tank.
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Blue PVC with plastic black caps for connections. 20 mm not self-estinguishing insulation.
WARRANTY
2 years
See general sales conditions and warranty.
1 Drain
ACQ. REF. ZC 20 OR
(20 mm Not self-estinguishing 2 Safety Valve
HYDRONIC
Model insulation) 3-4
To the System
Art. Nr. 5- 6
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
100 3001161030001 7
Connection for instrumentation 1/2” Gas F
200 3001161030002 8
300 3001161030003
500 3001161030004
INERTIAL
TANKS
800 3001161030005
0 L1 (4) (7) (3) L2 (6) (5)
1000 3001161030006
1500 3001161030107 H3
2000 3001161030108
2500 3001161030113
WATER PRESSURE
3000 3001161030109
4000 3001161030110 H2 (1) (7)
TANKS
Df
(8) (2)
5000 3001161030112
H1 (4) (6)
COMPRESSED AIR
0
RECEIVERS
L3 L4 (8) L5
L
100 32 99 400 934 215 720 290 415 645 63 293 523 1"1/4 1"1/2 1/2"
200 53 187 450 1339 230 1110 335 480 1005 61 316 571 1"1/4 1"1/2 1/2"
300 68 288 550 1389 275 1115 365 525 1025 115 425 760 1"1/4 2" 1/2"
500 102 496 650 1689 320 1370 415 570 1275 107 472 857 1"1/4 3" 1/2"
800 148 788 750 2000 350 1650 480 650 1520 101 516 951 1"1/4 3" 1/2"
1000 170 1034 850 2066 383 1683 513 683 1553 96 561 1046 1"1/2 3" 1/2"
1500 184 1432 950 2250 370 1880 505 670 1745 82 597 1142 2" 3" 1/2"
2000 220 1970 1100 2320 405 1915 525 705 1795 73 663 1283 2" 3" 1/2"
TECHNICAL
SUPPORT
2500 284 2300 1250 2140 470 1670 620 770 1520 154 829 1524 2" 4" 1/2"
3000 330 2908 1250 2640 470 2170 620 870 2020 154 829 1524 2" 4" 1/2"
4000 452 3749 1400 2730 515 2215 665 915 2065 142 892 1662 2" 4" 1/2"
5000 574 4964 1600 2790 545 2245 695 945 2095 125 975 1845 2" 4" 1/2"
263
AUTOCLAVE ZINCATA Z PED VT
CERTIFIED VERTICAL GALVANIZED PRESSURE VESSEL (STANDARD 2014/68/UE)
S T O C K Working Working
AVAILABILITY AUTOCL. Z VT AUTOCL. Z VT
grey Model Pressure Model Pressure
Art. Nr. [Bar] Art. Nr. [Bar]
100 3052171990001 100 3052171990015
200 3052171990022 200 3051171990074
300 3052171990003 300 3051171990025 11,76
500 3052171990004 500 3051171990026
750 3052171990025 750 3051171990077
1000 3052171990026 1000 3051171990078
1500 3051171990015 1500 3051171990029
2000 3051171990016
8 2000 3051171990030
12
2500 3051171990017 2500 3051171990031
3000 3051171990068 3000 3051171990082
PRESSURE TEMPERATURE
4000 3051171990019 4000 3051172020008
Pmax Tmax 5000 ø1450 3051171990020 5000 ø1450 3051172020004
[vedi tabella] -10 / +50 °C 5000 ø1600 3051172020007 8000 3051172020013
8000 3051172020011 10000 3051172020014
10000 3051172020012
Models from 100 to 1000 are provided with the Models from 100 and 500 are provided with security
security valve and the pressure gauge. valve and the pressure gauge.
Models 5000 (Ø1600), 8000 and 1000 are provided Models from 4000 to 10000 are provided with the
with the manhole. manhole.
150
CE 100 3052170990001 100 3052170990015
1000
200 3052170990022 200 3051170990072
11,76
TY
CI
8
50
300
Facilities
with 1
bathroom
5 10 15 20 25 30 35 40
2000
3000
4000
3051170990016
3051170990068
3051170990019
2000
2500
3000
3051170990030
3051170990041
3051170990082
12
Facilities
with 2
5 10
15
20
30
5000 3051170990020 4000 3051170990042
bathrooms
5000 3051170990044
Facilities
2 10 15
with 3
bathrooms
264
AUTOCLAVE ZINCATA Z PED VT
EXTRA- BOLLY®
CALORIFIERS
CERTIFIED VERTICAL GALVANIZED PRESSURE VESSEL (STANDARD 2014/68/UE)
1 Drain
De 2
BOLLYTERM®
3 Supply - Use
CALORIFIERS
(10) 4
5 Visual level indicator
6
Control features
7
8 Level switch – Pressure switch
9 Visual level indicator
STAINLESS STEEL
H5 (11) (9) (13
CALORIFIERS
10 Safety Valve
11 Level switch – Pressure switch
12 Manhole 400 x 300 (if required)
CALORIFIERS FOR
A
(3) (11)
HEAT PUMP
H4 (8)
H
H6 (12)
(10) Manometer Safety Valve
CYLINDERS - PUFFER
MULTIFUEL ENERGY
(8) As standard for pressure vessels from
H2 (4) (3) (2) 100 to 1000 lt (8 bar)
The LEVEL
INDICATOR KIT is
(4) (7) (2) (5) (9) available on demand.
See the Accessories
H1 (1)
(12) (6) (13) section for further
0
HYDRONIC
information.
INERTIAL
TANKS
100 400 1055 1065 90 350 500 600 800 - 1"1/4 1” - 1/2” 1" 1/4
200 450 1420 1435 85 355 655 755 1155 - 1"1/4 1” - 1/2” 1" 1/4
300 550 1530 1555 140 435 735 835 1235 - 1"1/4 1" 1/4 - 1/2” 1" 1/4
WORKING PRESSURE
500 650 1825 1840 135 455 855 955 1505 - 1"1/4 1" 1/2 - 1/2” 1" 1/4
WATER PRESSURE
750 790 1865 1880 115 515 965 1065 1465 - 1"1/4 1" 1/2 - 1/2” 1" 1/4
8 bar
1000 790 2380 2395 110 520 1020 1120 1920 - 1"1/4 1" 1/2 - 1/2” 1" 1/4
TANKS
1500 950 2470 2490 115 570 1070 1170 2020 - 2" 2” - 1/2” 1" 1/4
2000 1100 2535 2560 100 595 1095 1195 2045 - 2" 2” - 1/2” 1" 1/4
2500 1200 2660 2690 140 680 1280 1380 2130 - 2" 3” - 1/2” 1" 1/4
3000 1200 3000 3075 135 720 1320 1420 2420 - 2" 3" - 1/2” 2”
4000 1450 3000 3030 115 710 1310 1410 2410 - 2" 3" 2" 1/2” 2"
COMPRESSED AIR
5000 1450 3500 3525 115 710 1610 1710 2910 - 2" 3" 2" 1/2” 2"
RECEIVERS
5000 1600 3050 3090 100 725 1325 1425 2425 1025 2" 3" 2" 1/2” 2"
Models from 100 to 1000 are provided with security valve and pressure gauge. Models 5000 (Ø1600), 8000 and 10000 are provided with the manhole.
100 400 1055 1065 90 350 500 600 800 - 1"1/4 1" - 1/2" 1"1/4
11,76 bar
200 450 1420 1435 85 355 655 755 1155 - 1"1/4 1" - 1/2" 1"1/4
ACCESORIES
WORKING PRESSURE
300 550 1530 1540 140 435 735 835 1235 - 1"1/4 1"1/4 - 1/2" 1"1/4
500 650 1825 1840 135 455 855 955 1505 - 1"1/4 1"1/2 - 1/2" 1"1/4
750 790 1865 1880 115 515 965 1065 1465 - 1"1/4 1"1/2 - 1/2" 1"1/4
1000 790 2380 2395 110 520 1020 1120 1920 - 1"1/4 1"1/2 - 1/2" 1"1/4
1500 950 2490 2515 115 570 1070 1170 2020 - 2" 2" - 1/2" 1"1/4
12 bar
2000 1100 2535 2560 100 595 1095 1195 2045 - 2" 2" - 1/2" 1"1/4
2500 1200 2660 2690 140 680 1280 1380 2130 - 2" 3" - 1/2" 1"1/4
TECHNICAL
3000 1200 3000 3075 135 720 1320 1420 2420 - 2" 3" - 1/2" 2"
SUPPORT
4000 1450 3000 3030 115 710 1310 1410 2410 1011 2" 3" 2" 1/2" 2"
5000 1450 3500 3525 115 710 1610 1710 2910 1165 2" 3" 2" 1/2" 2"
Models from 100 to 500 are provided with security valve and pressure gauge. Models from 4000 to 10000 Lt are provided with the manhole.
265
AUTOCLAVE INOX X PED VT
CERTIFIED VERTICAL 316L STAINLESS STEEL PRESSURE VESSEL (DIRECTIVE 2014/68/UE)
HORIZONTAL VERSION
De
solo su capacità
> 1000 lt
(10)
1 Drain
2-3-4 Input - use
5 Visual level indicator
H5 (9) (11) 6-7 Control elements
8 Level switch – Pressure switch
9 Visual level indicator
10 Safety Valve
11 Level switch – Pressure switch
A
H4 (8) (3)
H
(10)
(8) (11)
H2 (4) (3) (2)
Manometer Safety Valve
As standard for pressure vessels from
(4) (7) (2) (5) (9) 100 to 1000 lt (8 bar)
H1 (1)
(6)
0
266
SERBATOIO INOX X SC VT
EXTRA- BOLLY®
CALORIFIERS
VERTICAL 316L STAINLESS STEEL TANK FOR PRESSURIZED COLD WATER STORAGE
BOLLYTERM®
CALORIFIERS
SERB. X SC VT
Model
Art. Nr.
STAINLESS STEEL
100 3251012010001
CALORIFIERS
200 3251012010002
300 3251012010003
500 3251012010004
1000 3251012010006
1500 3251012010007
2000 3251012010008
2500 3251012010009
CALORIFIERS FOR
PRESSURE TEMPERATURE
HEAT PUMP
3000 3251012010010 S T O C K
4000 3251012010011 AVAILABILITY
grey Pmax Tmax
5000ø1600 3251012010013
6 bar 0 / +50 °C
CYLINDERS - PUFFER
Pressurized cold water storage. Tanks for pressurized water storage are designed AISI 304 Stainless steel suitable for drinkable water according to D.M. n.174 dated
MULTIFUEL ENERGY
for those water systems that need to store pressurized cold water. 06.04.04.
They cannot work as pressure vessels. WARRANTY
These products are made in AISI 304 Stainless steel. 2 years
See general sales conditions and warranty.
HYDRONIC
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
De
(10)
1 Drain
2
INERTIAL
TANKS
Input - use
3
H5 (9) (11)
4
5
6
WATER PRESSURE
7 Instrumentation
A
H4 (8) (3) 8
TANKS
H
2500 1200 2628 2655 118 648 1198 1373 2098 1" 1/4 3" 1/2” 1"
3000 1250 2875 2905 116 645 1295 1395 2345 1" 1/4 3" 1/2” 1"
4000 1450 2970 3005 90 710 1330 1530 2380 1" 1/4 3" 1/2” 1"
5000 ø1600 1600 3005 3045 69 717 1337 1537 2387 1" 1/4 3" 1/2” 1"
267
SERBATOIO ZINCATO Z SC VT
VERTICAL GALVANIZED TANK FOR PRESSURIZED COLD WATER STORAGE
SERB. Z SC VT
Model
Art. Nr.
50 3251161990001
100 3251161990002
200 3251161990003
300 3251161990004
500 3251161990005
750 3251161990006
S T O C K 1000 3251161990007
grey
AVAILABILITY 1500 3251161990008
2000 3251161990009
PRESSURE TEMPERATURE
Pmax Tmax
6 bar 0 / +50 °C
De
(10)
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
1 Drain
2
Input - use
H5 (9) (11) 3
4
5
6
Instrumentation
7
A
H4 (8) (3)
8
H
(10)
(8) (11)
H2 (4) (3) (2)
268
SERBATOIO ZINCATO Z SC OR
EXTRA- BOLLY®
CALORIFIERS
HORIZONTAL GALVANIZED TANK FOR PRESSURIZED COLD WATER STORAGE
BOLLYTERM®
CALORIFIERS
SERB. Z SC OR
Model
Art. Nr.
100 3251160990001
200 3251160990002
300 3251160990003
STAINLESS STEEL
500 3251160990004
CALORIFIERS
750 3251160990005
1000 3251160990006
1500 3251160990007
2000 3251160990008
CALORIFIERS FOR
PRESSURE TEMPERATURE
HEAT PUMP
Pmax Tmax
6 bar 0 / +50 °C
CYLINDERS - PUFFER
Pressurized cold water storage. These tanks are galvanized inside and outside, with immersion in a pool of fused
MULTIFUEL ENERGY
Tanks for pressurized water storage are designed for those water systems that zinc with pureness not below 99,99% (Uni EN 1179)
need to store pressurized cold water. They cannot work as pressure vessels. WARRANTY
These products are made in galvanized mild steel. 2 years
See general sales conditions and warranty.
HYDRONIC
P.E.D. product designed and produced in conformity to the article 4.3 of directive 2014/68/UE - ErP Ecodesgin directive 2009/125/CE
1 L1 L3 L4 L5 L7
Drain 0 (4) (3) (7) (10) (8) (9) (6) (5)
2
3 H3
Safety Valve/Instrumentation
INERTIAL
TANKS
5
4
Input - use
6
7
8
WATER PRESSURE
H2 (1) (7) (8) (9) (2)
De
Instrumentation
9
TANKS
10
H1 (4) (6)
0
COMPRESSED AIR
L2 L6
RECEIVERS
L
AND SPARE PARTS
ACCESORIES
500 650 1700 325 420 650 850 1050 1280 1375 115 470 870 1” 1/4 1” 1/2 1” 1/2 1/2”
750 750 2010 355 485 805 1005 1205 1525 1655 108 513 948 1” 1/4 1” 1/2 1” 1/2 1/2”
1000 850 2060 380 510 830 1030 1230 1550 1680 102 557 1042 1” 1/2 1” 1/2 1” 1/2 1/2”
1500 950 2368 460 565 935 1185 1435 1805 1910 85 595 1140 2” 2” 2” 1/2”
2000 1100 2450 500 590 975 1225 1475 1860 1950 72 657 1277 2” 2” 2” 1/2”
269
VASO A MEMBRANA VERNICIATO PED VT
VERTICAL PAINTED EXPANSION VESSEL WITH MEMBRANE (DIRECTIVE 2014/68/UE)
VASO MEMB. V PED VT
Model
Art. Nr.
50 3911162241007
80 3911162241008
100 3911162241003
S T O C K 200 3911162241004
grey
AVAILABILITY 300 3911162241005
500 3911162241006
Working
De condition
Temp. Press.
(1) De H H1 1 2 3
Model min/max max
[mm] Connections Gas [°C] [bar]
50 400 627 91 1” M - -10/+99 10
Air inlet valve
80 450 717 88 1” M - -10/+99 10
Water
100 450 872 88 1/2” 1” M in/out -10/+99 10
Instrumenta- Air inlet
200 550 1187 151 1/2” tion 1” 1/4 F valve -10/+99 10
350
355
270
VASO A MEMBRANA VERNICIATO PED OR
EXTRA- BOLLY®
CALORIFIERS
HORIZONTAL PAINTED EXPANSION VESSEL WITH MEMBRANE (DIRECTIVE 2014/68/UE)
VASO MEMB. V PED OR
BOLLYTERM®
CALORIFIERS
Model
Art. Nr.
50 3911161341007
80 3911161341008
100 3911161341003 S T O C K
200 3911161341004 AVAILABILITY
grey
STAINLESS STEEL
300 3911161341005
CALORIFIERS
TECHNICAL DESCRIPTION MEMBRANE
Horizontal V PED expansion vessels with membrane are used for lifted water Elastic EPDM membrane suitable for drinking water.
system and they represent a pressurised water lung that, if duly dimensioned ,
reduces pump cycling. CERTIFICATIONS
CALORIFIERS FOR
The peculiarity of this product is the physic separation between water and air V PED OR expansion vessels with membrane are preduced in accordance with
HEAT PUMP
made by the membrane. safety disposal of European Directive 2014/68/UE in terms of pressurized.
They are CE labelled with design data:
APPLICATION - pressurized fluid: water+air or nitrogen
Perfect to ensure water deliveries to the top floors of the building or to work in - Fluid group: 2
case of insufficient water supplied by waterworks, or to stabilize pressure in the - max. working pressure: 10bar
domestic water supply by absorbing expansion when the water is heated.
DOCUMENTS ATTACHED
CYLINDERS - PUFFER
MULTIFUEL ENERGY
MATERIAL • CE certification
Painted mild steel. • User Instructions
L Working
condition
(3) Temp. Press.
De H H1 1 2 3
HYDRONIC
Model min/max max
[mm] Connections Gas [°C] [bar]
50 400 424 583 1” M - -10/+99 10
Air inlet valve
(1) (2) 80 450 473 598 1” M - -10/+99 10
De
Water
100 450 473 783 1/2” 1” M in/out -10/+99 10
Instrumenta- Air inlet
200 550 583 1066 1/2” tion 1” 1/4 F valve -10/+99 10
INERTIAL
TANKS
Used as air Used as
cushion pressure expansion
vessels vessel
Temp. Press. Temp. Press.
De H H1 1 2 3
WATER PRESSURE
Model min/max max min/max max
[mm] Connections Gas [°C] [bar] [°C] [bar]
TANKS
1/2” Water
300 650 807 1080 1” 1/4 F Air inlet valve -10/+50 10 -10/+99 6
Instrumentation in/out
COMPRESSED AIR
RECEIVERS
234
ACCESORIES
183
40
36
63÷157
N° 2 holes Ø Ø1010
N° 2 fori
142
N° 2 holes
N° 2 foriØØ99 80
62÷146
65
11
88÷175
10
49
TECHNICAL
68÷135
205
SUPPORT
180
11
10
72÷135 84÷172
271
VASO A MEMBRANA ZINCATO PED VT
VERTICAL GALVANIZED EXPANSION VESSEL WITH MEMBRANE (DIRECTIVE 2014/68/UE)
VASO MEMB. Z PED VT
Model
Art. Nr.
50 3911161991007
80 3911161991008
100 3911161991003
S T O C K 200 3911161991004
grey
AVAILABILITY 300 3911161991005
500 3911161991006
Working
De condition
Temp. Press.
(1) De H H1 1 2 3
Model min/max max
[mm] Connections Gas [°C] [bar]
50 400 627 91 1” M - -10/+99 10
Air inlet valve
80 450 717 88 1” M - -10/+99 10
Water
100 450 872 88 1/2” 1” M in/out -10/+99 10
Instrumenta- Air inlet
200 550 1187 151 1/2” tion 1” 1/4 F valve -10/+99 10
350
355
272
VASO A MEMBRANA ZINCATO PED OR
EXTRA- BOLLY®
CALORIFIERS
HORIZONTAL GALVANIZED EXPANSION VESSEL WITH MEMBRANE (DIRECTIVE 2014/68/UE)
VASO MEMB. Z PED OR
Model
BOLLYTERM®
CALORIFIERS
Art. Nr.
50 3911160991007
80 3911160991008
100 3911160991003
200 3911160991004 S T O C K
300 3911160991005 grey
AVAILABILITY
STAINLESS STEEL
500 3911160991006
CALORIFIERS
TECHNICAL DESCRIPTION MEMBRANE
Horizontal Z PED expansion vessels with membrane are used for lifted water Elastic EPDM foodstuff membrane suitable for drinking water.
system and they represent a pressurised water lung that, if duly dimensioned , CERTIFICATIONS
CALORIFIERS FOR
reduces pump cycling. Z PED OR expansion vessels with membrane are preduced in accordance with
HEAT PUMP
The peculiarity of this product is the physic separation between water and air safety disposal of European Directive 2014/68/UE in terms of pressurized.
made by the membrane. They are CE labelled with design data:
APPLICATION - pressurized fluid: water+air or nitrogen
Perfect to ensure water deliveries to the top floors of the building or to work in - Fluid group: 2
case of insufficient water supplied by waterworks, or to stabilize pressure in the - max. working pressure: 10bar
domestic water supply by absorbing expansion when the water is heated. DOCUMENTS ATTACHED
MATERIAL • CE certification
CYLINDERS - PUFFER
MULTIFUEL ENERGY
External lining: galvanized mild steel. • User Instructions
L Working
condition
(3) Temp. Press.
De H H1 1 2 3
HYDRONIC
Model min/max max
[mm] Connections Gas [°C] [bar]
50 400 424 583 1” M - -10/+99 10
Air inlet valve
(1) (2) 80 450 473 598 1” M - -10/+99 10
De
Water
100 450 473 783 1/2” 1” M in/out -10/+99 10
Instrumenta- Air inlet
200 550 583 1066 1/2” tion 1” 1/4 F valve -10/+99 10
INERTIAL
TANKS
Used as air Used as
cushion pressure expansion
vessels vessel
Temp. Press. Temp. Press.
De H H1 1 2 3
WATER PRESSURE
Model min/max max min/max max
[mm] Connections Gas [°C] [bar] [°C] [bar]
TANKS
300 650 807 1080 1/2” 1” 1/4 F Water -10/+50 10 -10/+99 6
Air inlet valve
500 750 900 1350 Instrumentation 1” 1/4 F in/out -10/+50 10 -10/+99 6 COMPRESSED AIR
RECEIVERS
183
ACCESORIES
40
36
63÷157
N° 2 holes ØØ10
N° 2 fori 10
142
N° 2 N°
holes
2 foriØØ 10
9 80
62÷146
65
11
88÷175
10
49
68÷135
205
180
TECHNICAL
SUPPORT
11
10
72÷135 84÷172
273
274
275
RECEIVERS
COMPRESSED AIR
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
ARIA COMPRESSA CE
COMPRESSED AIR / NITROGEN RECEIVERS (DIRECTIVE 2014/29/CE)
AIR
COMPRESSOR
WORKING TEMPERATURE
Tmax
-10/+100 °C
Working Pressure PAINTED RAL 5002 BLUE (*) - FOOD INTERNAL COATED
Model
[Bar] [€]
100
200
270
500 11 on request
710
900
15
270
(*) Other colours on demand: RAL 5015 Light Blue / RAL on request
3000 Red / RAL 1021 Yellow 500
276
EXTRA- BOLLY®
ARIA COMPRESSA CE
CALORIFIERS
COMPRESSED AIR / NITROGEN RECEIVERS (DIRECTIVE 2014/29/CE)
De
(6)
BOLLYTERM®
CALORIFIERS
1 Drain
2-3 Air entry
4-5 Utilizzo
H4 (4) (8) (5)
6 Safety Valve
STAINLESS STEEL
H3 (7) 7-8 Instrumentation
CALORIFIERS
A
CALORIFIERS FOR
HEAT PUMP
H2 (2) (3)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H1 (1)
0
Working
De H A H1 H2 H3 H4 1-6 2-3-4-5 7 8
Model Pressure
[bar] [mm] Connections Gas F
100 400 1105 1125 145 380 790 870 2” 1” 3/8” 3/8”
200 450 1470 1490 145 385 1125 1225 2” 1” 3/8” 3/8”
HYDRONIC
270
500 11 500
650
1760
1850
1780
1870
150
170
410
485
1330
1285
1450
1485
2”
2”
1”
2”
3/8”
3/8”
3/8”
3/4”
710 790 1900 1930 135 585 1360 1460 2” 2” 3/8” 3/4”
900 790 2130 2160 145 490 1390 1590 2” 2” 3/8” 3/4”
15
270 500 1760 1780 150 410 1330 1450 2” 1” 3/8” 3/8”
500 650 1850 1870 170 485 1285 1485 2” 2” 3/8” 3/4”
INERTIAL
EXAMPLE OF COMPRESSED AIR RECEIVER PLANT
TANKS
In compressed air production and distribution systems, tanks are used in production 100 Nm3/min, tank capacity is calculated, as a first approximation, with the following
plants for the following functions: relationship:
• to store compressed air in order to use it when needed V= 0.2 to 0.6 Q
• to ensure network air flow and constant pressure by limiting interventions to adjust V = theoretical volume of the tank in m3
WATER PRESSURE
the flow; Q = intake flow rate from the compressor in m3/min
• to favour the separation of condensation through the release of the flow coming from 0.2 = coefficient for large plants
the compressor in the bottom of the tank and connecting delivery in the upper. 0.6 = coefficient for small plants
TANKS
Furthermore, the tanks are located near uses characterised by highly variable air
requirements in order to limit pressure fluctuations along the distribution lines.
Optimum tank volume in a production system depends on the type of compressor,
environmental conditions of operation and type of use.
In systems characterised by max operating pressure of 10 bar and flow rates from 1 to
COMPRESSED AIR
RECEIVERS
Tank
AND SPARE PARTS
ACCESORIES
Pre filter
Services
Filters
TECHNICAL
SUPPORT
Air Dryer
Compressor
Draining
Drain Treatment
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
277
ARIA COMPRESSA P.E.D.
COMPRESSED AIR / NITROGEN RECEIVERS (DIRECTIVE 2014/68/UE - P.E.D.)
AIR
COMPRESSOR
WORKING TEMPERATURE
Tmax
-10/+100 °C
DOCUMENTS ATTACHED
• CE certification - User Instructions
grey
1500 3054171990001 3054172240001
2000 3054171990002 3054172240002
3000 3054171990054 3054172240054
4000
5000
8 3054171990005
3054171990006
3054172240005
3054172240006
8000 3054171990007 /
10000 3054171990008 /
1000 3054171990067 3054172240067
1500 3054171990011 3054172240011
2000 3054171990012 3054172240012
2500 3054171990013 3054172240013
3000
4000
12 3054171990064
3054171990015
3054172240064
3054172240015
5000 3054171990016 3054172240016
8000 3054171990027 /
10000 3054171990028 /
(*) Other colours on demand: RAL 5015 Light Blue / RAL 1000 3054171990167 3054172240151
3000 Red / RAL 1021 Yellow 1500
2000
15 3054171990118
3054171990168
3054172240102
3054172240152
FOOD INTERNAL COATING
5000
1000
1500
2000
2500
3000
12 on request
4000
5000
(*) Other colours on demand: RAL 5015 Light Blue / RAL 1000
3000 Red / RAL 1021 Yellow 1500
2000
15 on request
278
EXTRA- BOLLY®
ARIA COMPRESSA P.E.D.
CALORIFIERS
COMPRESSED AIR / NITROGEN RECEIVERS (DIRECTIVE 2014/68/UE - P.E.D.)
De
1 Drain
(6) 2-3 Air entry
BOLLYTERM®
CALORIFIERS
4-5 Utilizzo
6 Safety Valve
7-8 Instrumentation
9 Manhole / handhole (on request)
H4 (4) (8) (5)
STAINLESS STEEL
CALORIFIERS
H3 (7)
Accessories
CALORIFIERS FOR
HEAT PUMP
H5 (9)
Galvanized
l d Painted
H2 (2) (3)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
H1 (1)
0
Working Pressure De H A H1 H2 H3 H4 1-6 2-3-4-5 7 8
Model
[bar] [mm] Connections Gas F
HYDRONIC
1500 950 2470 2510 150 570 1470 1670 2” 2” 3/8” 3/4”
2000 1100 2545 2600 100 595 1495 1695 2” 2” 3/8” 3/4”
3000 1200 3000 3075 140 720 1620 1820 2” 3” 3/8” 3/4”
4000
5000
8 1450
1450
3000
3505
3100
3585
120
115
710
710
1610
2100
1810
2300
2”
2”
3”
3”
3/8”
3/8”
3/4”
3/4”
8000 1650 4200 4280 220 810 3310 3510 2” 4” 3/8” 3/4”
10000 1650 5200 5270 220 810 4310 4510 2” 4” 3/8” 3/4”
1000 790 2430 2450 180 575 1625 1825 2” 2” 3/8” 3/4”
INERTIAL
TANKS
1500 950 2490 2530 115 575 1480 1680 2” 2” 3/8” 3/4”
2000 1100 2545 2600 100 595 1495 1695 2” 2” 3/8” 3/4”
2500 1200 2660 2760 145 680 1580 1780 2” 3” 3/8” 3/4”
3000
4000
12 1200
1450
3000
3000
3075
3100
140
120
720
710
1620
1610
1820
1810
2”
2”
3”
3”
3/8”
3/8”
3/4”
3/4”
WATER PRESSURE
5000 1450 3505 3585 115 710 2100 2300 2” 3” 3/8” 3/4”
8000 1650 4200 4280 220 810 3310 3510 2” 4” 3/8” 3/4”
TANKS
10000 1650 5200 5270 220 810 4310 4510 2” 4” 3/8” 3/4”
1000 790 2430 2450 180 575 1625 1825 2” 2” 3/8” 3/4”
1500
2000
15 950
1100
2490
2545
2530
2600
115
100
575
595
1480
1495
1680
1695
2”
2”
2”
2”
3/8”
3/8”
3/4”
3/4”
In compressed air production and distribution systems, tanks are used in production plants for the following functions:
• to store compressed air in order to use it when needed
• to ensure network air flow and constant pressure by limiting interventions to adjust the flow;
• to favour the separation of condensation through the release of the flow coming from the compressor in the bottom of the tank and connecting delivery in the upper.
Tank Furthermore, the tanks are located near uses characterised
by highly variable air requirements in order to limit pressure
AND SPARE PARTS
Compressor
Air Dryer Q = intake flow rate from the compressor in m3/min
Draining
Drain Treatment
0.2 = coefficient for large plants
0.6 = coefficient for small plants
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
279
280
281
ACCESSORIES
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
ACCESSORIES AND SPARE PARTS :
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
LOWER HEAT EXCHANGER FOR EXTRA 1,2 3 VT CALORIFIERS
The Antilegionella® coil, which is the heat exchanger with tubes bent to the bottom is
an efficient innovation installed as a standard on every Cordivari’s Extra calorifiers.
This reduces the diffusion of legionellosis bacterium.
Advantages:
• The Antilegionella® curved heat exchanger can heat the complete quantity of water
Def
in an homogenous way. Even in the bottom area of the boiler which is impossible with
traditional heat exchanger.
• Possibility of using lower capacity boilers for the same quantity of hot water needed.
Kit including: exchanger, gaskets, bolts and insulated bushes.
B
[m ]
2
[mm]
1,5 380 496 336 5221000010103 • EXTRA1 WXC 800 - EXTRA 1 XXC 800
ADDITIONAL COPPER FINNED COIL (FOR 800 AND 1000 MODELS BOLLY® ST 1 - 2)
Art. Nr. Description COPPER finned coil for Bolly FIT 1 - 2 ≥ 800 lt,
3/4” including flange plate (Ø 240 mm), gaskets, bolts
3/4” 5221000910001 Surface=0,94m2 - De=145 mm - L=370 mm and user manual.
282
ACCESSORIES AND SPARE PARTS :
EXTRA- BOLLY®
CALORIFIERS
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
MIDDLE AND UPPER HEAT EXCHANGERS FOR CALORIFIERS EXTRA 2 E 3 VT AND EXTRA 1 OR
BOLLYTERM®
CALORIFIERS
Kit including: exchanger, gaskets, bolts and insulated
bushes.
Def
STAINLESS STEEL
CALORIFIERS
A
STRAIGHT EXCHANGER
CALORIFIERS FOR
STAINLESS STEEL 316L WITH SILICONE GASKET
HEAT PUMP
AVAILABLE FOR
Heat exchanger
Def A
surface Art. Nr.
[m ]
2
[mm]
• EXTRA1 WXC OR 200 • EXTRA2 WXC 200
CYLINDERS - PUFFER
0,5 300 445 5221000010074 ---
MULTIFUEL ENERGY
EXTRA1 XXC OR 200 EXTRA2 XXC 200
HYDRONIC
• EXTRA1 WXC OR 800
1,5 380 600 5221000010078 --- • EXTRA3 WXC 1500
EXTRA1 XXC OR 800
• EXTRA2 WXC 800
• EXTRA1 WXC OR 1000
2 380 560 5221000010079 EXTRA2 WXC 1000 • EXTRA3 WXC 2000
EXTRA1 XXC OR 1000
EXTRA2 XXC 1000
• EXTRA2 WXC 1500
• EXTRA1 WXC OR 1500
3 380 720 5221000010080 EXTRA2 XXC 1500 • EXTRA3 WXC 3000
EXTRA1 XXC OR 1500
INERTIAL
• EXTRA3 WXC 1500
TANKS
• EXTRA2 WXC 2000
• EXTRA1 WXC OR 2000
4 430 750 5221000010081 EXTRA2 XXC 2000 • EXTRA3 WXC 4000
EXTRA1 XXC OR 2000
• EXTRA3 WXC 2000
WATER PRESSURE
EXTRA1 XXC OR 3000 EXTRA2 XXC 2500
TANKS
EXTRA2 WXC 3000 EXTRA3 WXC 3000
6 430 890 5221000010122 ---
EXTRA2 XXC 3000 EXTRA3 XXC 3000
EXTRA2 WXC 4000
• EXTRA1 WXC OR 4000
8 430 1250 5221000010083 EXTRA2 XXC 4000 ---
EXTRA1 XXC OR 4000
EXTRA3 WXC 4000
EXTRA2 WXC 5000
COMPRESSED AIR
COPPER FINNED AND TINNED HEAT EXCHANGERS (AVAILABLE ON EXTRA PLUS - INERTIAL TANKS)
AND SPARE PARTS
TECHNICAL
283
ACCESSORIES AND SPARE PARTS :
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
COMPATIBLE ELECTRICAL KITS
Following charts indicate the electrical kits compatible with Cordivari calorifiers range. Operating time expressed in minutes and DHW volume are shown below.
COMPATIBLE WITH:
284
ACCESSORIES AND SPARE PARTS :
EXTRA- BOLLY®
CALORIFIERS
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
ELECTRICAL IMMERSION HEATERS ELECTRICAL IMMERSION HEATERS
MONOPHASE MONOPHASE
1,5 kW 2 kW 3 kW 1,5 kW 2 kW 3 kW
BOLLYTERM®
Volume of Volume of
CALORIFIERS
water heated water heated
5240000000051 5240000000052 5240000000053 5240000000051 5240000000052 5240000000053
Mod. by the electrical Mod. by the electrical
immersion Ignition time from 10 °C to 45 °C with immersion immersion Ignition time from 10 °C to 45 °C with immersion
[lt] heaters [min] [lt] heaters [min]
150 42 76 57 38 200 54 88 60 44
200 44 78 59 39 300 105 188 141 94
300 80 143 107 71 500 172 307 230 154
STAINLESS STEEL
400 126 226 170 113
COMPATIBLE WITH:
CALORIFIERS
500 185 331 248 165
COMPATIBLE WITH:
BOLLY® 2 AP
BOLLY® 1 AP
ELECTRICAL IMMERSION HEATERS ELECTRICAL IMMERSION HEATERS
CALORIFIERS FOR
HEAT PUMP
MONOPHASE MONOPHASE
Volume of 1,5 kW 2 kW 3 kW Volume of 1,5 kW 2 kW 3 kW
water heated 5240000000051 5240000000052 5240000000053 water heated
5240000000051 5240000000052 5240000000053
Mod. by the electrical Mod. by the electrical
immersion Ignition time from 10 °C to 45 °C with immersion immersion Ignition time from 10 °C to 45 °C with immersion
[lt] heaters [min] [lt] heaters [min]
200 166 298 223 149 300 169 274 206 137
CYLINDERS - PUFFER
MULTIFUEL ENERGY
300 245 439 329 219 500 305 496 372 248
500 424 759 569 380
COMPATIBLE WITH: COMPATIBLE WITH:
HYDRONIC
1,5 - 3 Kw
Electric heaters can be used as integration on calorifiers and tanks, stainless steel heaters,
protection class min IP44, supplied with thermostat, safety thermostat reset user and 2 mt
of electrical cable wired and without plug.
R
Tension Output Length L Connection R
103
Art. Nr.
IP65
04
05
VOLT - WATT
INERTIAL
03
Volt [Kw] [mm] Gas M
06
C
70
TANKS
5240000000051
220 V 1,5 320 103
L
18.5
5240000000052 2 320 1”1/2
5240000000053 MONOPHASE 3 320
Electric heaters can be used as integration on calorifiers and tanks, heating elements in 4-9 Kw
WATER PRESSURE
INCOLOY 800, protection class min IP44 supplied with thermostat, safety thermostat manual
reset and 2 mt of electrical cable wired and without plug.
TANKS
R
5240000000050 9 750
RECEIVERS
400 V
5240000000031 12 750 2"
TRIPHASE
AND SPARE PARTS
L
ACCESORIES
285
ACCESSORIES AND SPARE PARTS :
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
EXCHANGER HEAD FOR “EXTRA 1,2,3” CALORIFIERS
The Flange plate includes 2 sleeve collars for the connection to the Art. Nr. Connection Diameter [mm]
operating system. This allows the circulation of the liquid within the heat 5206000000001 1" 300
exchanger’s serpentine doing the real separation between the incoming 5206000000002 2" 380
liquid and the outgoing one. The flange plate is in mild steel. Blind flange
5206000000003 2" 430
for accumulation tank in Polywarm® available also with 1 connection.
Includes 2 gaskets, bolts and bushes
Including: gaskets, bolts and bushes
Version for pipes heat exchanger
Pair of gasket for boilers EXTRA PLUS and STORAGE TANKS Pair of gasket for boilers BOLLY® POLYWARM® (800 -1000) / INOX STORAGE TANKS
Art. Nr. Diameter [mm] Art. Nr. Diameter [mm]
5021220401013 300 5021220401012 240
One gasket with crosspiece and one without. One gasket with crosspiece and one without.
Silicone gaskets suitable for alimentary use for Silicone gaskets suitable for alimentary use for
max temperature up to 200°C. 5 UNITS BOX max temperature up to 200°C. 5 UNITS BOX
286
ACCESSORIES AND SPARE PARTS :
EXTRA- BOLLY®
CALORIFIERS
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
MAGNESIUM ANODES
The calorifiers corrosion protection is guaranteed not only by the internal coating material but also by
BOLLYTERM®
CALORIFIERS
the anodes.
As standard, Cordivari provides its calorifiers with magnesium anode and with electronic anode on
Anode with Chain anode demand.
insulated cap
Dimen. ADATTO PER
BOLLY® RANGE
STAINLESS STEEL
Art. Nr. Description Extra 1,2,3, Interka Interka, (ST, AP, XL,PDC
CALORIFIERS
[mm] Combi
Vasi Inerziale Solare Bolly Murale Classe.A)
Bollyterm® HP
N° 3 anodes + insulated cap + gasket -
5200000041001 32x 350 200 /300 WC – – 150 –
SUITABLE FOR ANODEN TESTER
1”1/4 Gas
N° 3 anodes + insulated cap + gasket -
5200000041002 32 x 450 – – – 200/300 –
1”1/4 Gas
N° 3 anodi + insulated cap + gasket -
CALORIFIERS FOR
5200000041003 32 x 520 500 WC – – 400 –
HEAT PUMP
1”1/4 Gas
N° 3 anodes + insulated cap + gasket -
5200000041004 32 x 650 800÷2000 WC (x2) – – 300/500/800 –
1”1/4 Gas
N° 2 anodes + insulated cap + gasket -
5200000041005 32 x 800 3000 WC (x2) – – – –
1”1/4 Gas
N° 2 anodes + insulated cap + gasket 1500÷4000 WC (x2)
5200000041006 32 x 900 – – 500 –
- 3/4” Gas 5000 WC (x2)
CYLINDERS - PUFFER
MULTIFUEL ENERGY
800
N° 2 chain anodes + insulated cap + gasket
5200000041007 22 x 631 – – – – 1000/1500
- 3/4” Gas
2000
N° 2 chain anodes + insulated cap + gasket
5200000041016 22 x 450 – 500/600
- 3/4” Gas
5200000041008 N° 2 anodes M8 32 x 200 – 150 – – –
HYDRONIC
5200000041010 N° 2 anodes + blind plug 1” 1/4 32 x 350 200/300 XC – 200/300 150/200 –
INERTIAL
5200000041014 N° 2 anodes + blind plug 1” 1/4 32 x 520 800 ZC e XC – – –
TANKS
(x2)
150/200
5200000041015 N° 2 anodes + blind plug 1” 1/4 32 x 200 – 80/100/150 – –
v2011
ELECTRONIC ANODE WITH TITANIUM IMPRESSED ELECTRICITY (FOR POLYWARM® COATED ONLY)
WATER PRESSURE
Anode length SUITABLE FOR
TANKS
Art. Nr. Conn.
Extra1,2,3 Interka, Interka Solare, BOLLY® RANGE
[mm]
Vasi Inerz. Polywarm Bolly Murale (ST, AP, XL,PDC Classe.A) Bollyterm® HP
5200000000008 200 200, 300 80, 100, 120, 150, 200, 300 150, 200, 300
5200000000009 500 500, 800 – 500
1”1/4
5200000000011 400 1000, 1500 – 300 ,800, 1000
Gas
COMPRESSED AIR
This system ensures the good working and a long life both to the anode and the 3. Definitive and easy protection. It is important anyway to check that the
cilinder. electricity is constantly working.
• Operating conditions 4. Cancelation of any worries and maintenance problems and costs.
The input disposal is positioned in a insulated box and it’s equipped with a light
led, located on front side. Green light=working OK – Red light = Wrong working.
ANODEN-TESTER
Art. Nr. Descrizione ANODEN TESTER KIT
TECHNICAL
5221000000031 Anoden-tester kit - 2 units box the consumption of the magnesium anode. You have just
to push the button to check if the anode has to be replaced.
Included with the anoden-tester, cap and boss.
287
ACCESSORIES AND SPARE PARTS :
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
EASY CONTROL : ELECTRONIC DISPLAY FOR CALORIFIERS
• 4 working possiblities . Manual + Daily – Weekly - weekend
• Control of 2 sources and an additional electrical immersion (Power up to 2500 W and running in Manual
mode)
• Antilegionellosis programme for time and temperature included with the output for the by-pass electronic-
valve to the thermostatic mixer.
• Working control of the system trough the Display
• Alert message for the temperature’s probes
• Control of the recycling pump
• Complete with 3 temperature’probes
VALVES KIT
RECYCLE KIT - ECO COMBI RECYCLE KIT AND MIXER - ECO COMBI
Art. Nr. Art. Nr.
5221000000019 5221000000020
3/4” Connection 3/4” Connection
288
ACCESSORIES AND SPARE PARTS :
EXTRA- BOLLY®
CALORIFIERS
CALORIFIERS - MULTYFUEL ENERGY CILINDERS
BUFFER TANKS CONNECTING KIT
BOLLYTERM®
CALORIFIERS
Stainless steel extensible connecting hose
Art. Nr. Connection Length
5006170001001 1” 1/2 200 ÷ 400 mm
STAINLESS STEEL
CALORIFIERS
ADJUSTABLE SUPPORTING FEET FOR BOLLY®
Art. Nr. Description 3 adjustable supporting feet, allowing a correct positioning of the Bolly
at not in-level floor.
5221000000029 Kit 3 adjustable supporting feet
CALORIFIERS FOR
HEAT PUMP
CYLINDERS - PUFFER
MULTIFUEL ENERGY
HYDRAULIC SAFETY GROUP
This accessory includes, a 8 bar safety valve, nonreturn valve, 2 on-off valves.
Art. Nr. Connection Pressure Its function is to protect tha sanitary circuit from overpressure (according to italian
5760000001001 1” 8 bar national regulation), fully covered inside the carter.
HYDRONIC
INERTIAL
TANKS
THERMOMETER
WATER PRESSURE
1/2” gas connection Thermometer- - from 0°-120°C
TANKS
Art. Nr. Description Diameter [mm]
5032240000107 5 units box 60 COMPRESSED AIR
RECEIVERS
AND SPARE PARTS
ACCESORIES
TECHNICAL
SUPPORT
289
ACCESSORIES AND SPARE PARTS :
HYDRONIC SYSTEMS
RECYCLE KIT FOR MACS® MODULE
Art. Nr. The use of Cordivari’s recycling kit allows to manage on the system a link of the DHW
5221000000054
recycling.
The benefit is to improve the comfort of the user and to reduce the waste and produ-
ce DHW immediately at the right temperature.
In particular, the Cordivari electronic recycling kit allows to:
• Maximize the energy saving by programming the recycling temperature on basis of
Control display + pump our own habits.
• Daily and weekly scheduling to manage until 8 time slots for each day of the week
(for D.H.W.) • Constantly monitoring the working and the efficiency of the recycle thanks to the
self-diagnostics of the system
• Works also without the temperature’s probe into system where the probe is not
foreseen, through programmable temporary actions.
5046000000007 3/4”
For further information and prices, see Cordivari INTEGRATED SOLAR SYSTEMS
5046000000008 1” catalogue.
290
ACCESSORIES AND SPARE PARTS :
EXTRA- BOLLY®
CALORIFIERS
HYDRONIC SYSTEMS
PHC - 316L STAINLESS STEEL PLATES SPARE PARTS
BOLLYTERM®
CALORIFIERS
Description
Suitable for Art. Nr.
316L STAINLESS STEEL PLATES
2 units box PHC 3120 5250400000011
2 units box PHC 4620 5250400000012
2 units box PHC 7420 5250400000013
Description Suitable for Art. Nr.
2 units box - H version PHC 7431 5250400000014
STAINLESS STEEL
PHC 3120 5250400000001 2 units box - L version PHC 7431 5250400000015
CALORIFIERS
N° 2 316L stainless steel PHC 4620 5250400000002 2 units box - H version PHC 8031 5250400000016
plates + gaskets already
PHC 7420 5250400000003 2 units box - L version PHC 8031 5250400000017
mounted
(until stocks are exhausted) PHC 7431 5250400000004 2 units box - H version PHC 12046 5250400000018
PHC 12046 5250400000005 2 units box - L version PHC 12046 5250400000019
CALORIFIERS FOR
HEAT PUMP
CYLINDERS - PUFFER
PHC - GASKETS
MULTIFUEL ENERGY
Description Suitable for Art. Nr.
NBR gaskets - 10 units box 5019220401011
PHC 3120
EPDM gaskets - 10 units box 5019220401012
NBR gaskets - 10 units box 5019220401013
PHC 4620
EPDM gaskets - 10 units box 5019220401014
NBR gaskets - 10 units box 5019220401015
HYDRONIC
PHC 7420
EPDM gaskets - 10 units box 5019220401016
NBR gaskets - 14 units box 5019220401017
PHC 7431
EPDM gaskets - 14 units box 5019220401018
NBR gaskets - 14 units box 5019220401019
PHC 8031
EPDM gaskets - 14 units box 5019220401020
NBR gaskets - 14 units box 5019220401021
PHC 12046
INERTIAL
TANKS
EPDM gaskets - 14 units box 5019220401022
WATER PRESSURE
TANKS
COMPRESSED AIR
RECEIVERS
AND SPARE PARTS
ACCESORIES
TECHNICAL
SUPPORT
291
ACCESSORIES AND SPARE PARTS :
WATER PRESSURE TANKS
PRESSURE VESSELS VISUAL LEVEL INDICATOR
The level indicator includes: transparent tube, two brass faucets and gaskets.
Tube length
Art. Nr. Pressure vessel model
[m]
From 100 to 2500 (stainless steel 1000 and
5303000000040 1
2000 excluded)
From 3000 to 5000 (stainless steel 1000
5303000000041 2
and 2000 included)
5303000000042 >5000 on request 3
MANOMETER
They indicate the pressure in the tank. All manometers have a red signed maximum level.
292
ACCESSORIES AND SPARE PARTS :
EXTRA- BOLLY®
CALORIFIERS
COMPRESSED AIR RECEIVERS
MANHOLE - HANDHOLE
BOLLYTERM®
CALORIFIERS
2014/68/UE Manhole (optional) Handhole (optional)
Working Pressure H5 9 H5 9
Model H5 (9)
[bar] [mm] [mm]
1500 818 400x300 818 150x100
STAINLESS STEEL
CALORIFIERS
2000 845 400x300 845 150x100
3000 985 400x300 985 150x100
4000 (*)
5000 (*)
8 1011
1161
400x300
400x300
1011
1161
150x100
150x100 0
8000 1163 400x300 standard 1163 150x100
CALORIFIERS FOR
HEAT PUMP
10000 1163 400x300 standard 1163 150x100
1000 818 400x300 840 150x100
1500 845 400x300 818 150x100
2000 978 400x300 845 150x100
CYLINDERS - PUFFER
2500 985 400x300 978 150x100
MULTIFUEL ENERGY
3000
4000 (*)
12 1011
1161
400x300
400x300
985
1011
150x100
150x100
5000 (*) 1163 400x300 1161 150x100
8000 1163 400x300 standard 1163 150x100
10000 1167 400x300 standard 1163 150x100
1000 / / 840 150x100
HYDRONIC
1500
2000
15 818
845
400x300
400x300
998,00 818
845
150x100
150x100
INERTIAL
TANKS
ACCESSORIES AND SPARE PARTS FOR AIR COMPRESSOR RECEIVERS
WATER PRESSURE
TANKS
Compressed Air Receivers Kit
Includes a safety valve , a gauge (manometer) and its
Art. Nr. Descrizione tap-tray.
Kit for 200 up to 710 lt compressed air receivers (11 bar), with security valve of
COMPRESSED AIR
5303000000001
7.500 l./min P calibration 10,4 bar
RECEIVERS
Kit for 900 lt compressed air receivers (11 bar), with security valve of 29.300 l./
5303000000002
min P calibration 10,4 bar
Kit for 1.000 up to 10.000 lt compressed air receivers (12 bar), with security valve
5303000000003
of 31.400 l./min P calibration 11,2 bar
AND SPARE PARTS
ACCESORIES
Kit for 1.000 up to 10.000 lt compressed air receivers (8 bar), with security valve
5303000000004
of 21.700 l./min P calibration 7,4 bar
Kit for 270 up to 2.000 lt compressed air receivers (15 bar), with security valve of
5303000000005
9.600 l./min P calibration 13,5 bar
TECHNICAL
SUPPORT
293
TECHNICAL
SUPPORT
& REGULATIONS
294
295
TECHNICAL ACCESORIES COMPRESSED AIR WATER PRESSURE INERTIAL MULTIFUEL ENERGY CALORIFIERS FOR STAINLESS STEEL BOLLYTERM® EXTRA- BOLLY®
SUPPORT AND SPARE PARTS RECEIVERS TANKS TANKS HYDRONIC CYLINDERS - PUFFER HEAT PUMP CALORIFIERS CALORIFIERS CALORIFIERS
INSULATIONS
THERMAL INSULATION
Thermal efficiency of calorifiers and buffer tanks Cordivari is optimized with special insulations, that are an essential component for every storaging of hot water, keeping stored
hot water at high temperature.
Cordivari insulations reduce at minimum level temperature losses, with consequently energy savings.
Insulation on calorifiers and buffer tanks are manufactured using the best available materials.
NOFIRE®
INSULATION
Hardfoam Polyuretane
F No performance declared
296
EXTRA- BOLLY®
CALORIFIERS
MATERIALS
All Cordivari Products are manufactured using high level quality of raw materials and internal finishes:
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
316L Stainless Steel
The choice of stainless steel material on calorifiers aims for an absolute quality Domestic Hot Water, resistant to low and high temperatures, 100% recyclable.
result. Cordivari is leader in the production of 316L stainless steel (EN 1.4404)
Material with high performances, entirely hygienic and atossic, suitable for calorifiers with high quality standard levels.
CALORIFIERS FOR
POLYWARM®
HEAT PUMP
WATER HYGIENE AND PROTECTION
• Drinkability and Hygiene at 100%;
Polywarm® • Elasticity E>20%;
• Capacities up to 6000 lt;
CYLINDERS - PUFFER
MULTIFUEL ENERGY
• Temperature resistance till 130°C;
• Thickness >200 μm for a total protection to corrosion.
Our customer oriented approach and our long tradition as cylinder manufacturer temperature resistance till 130°C. Thickness >200 μm for a total protection to
allow us to offer cutting edge solutions for production and storage of Domestic corrosion.
Hot Water Cylinders. Polywarm® Hygienic Certifications:
Polywarm® properties have passed the adherence tests according to BS3900-E6 • Certificate of conformity for Domestic Hot Water of organic coating for food
and DIN 53151, hardness tests according to ASTM D 3363-74 (matite), Impact uses Polywarm® granted by IPL (Institut Pasteur de Lille - France).
resistance test (2 Joule) according to BS3900-E6 and at 10 kg x cm (UNI 8901). • Test report of internal treatment for food use Polywarm® in accordance with
Polywarm® has excelled in chemical and durability testing (>1000 hours) in salt D.M. nr. 174 del 06/04/2004 granted by SSICA Laboratory of Parma - Italy.
HYDRONIC
spry testing according to UNI 5687-73 and Humidity cycle according to UNI • Certificate OFI - Vienna , Austria, according to DVGW W270-UBA.
8744. • WRAS - Water Regulation Advisory Scheme certificate
Drinkability and Hygiene at 100%, elasticity E>20%, capacities up to 6000 litres,
INERTIAL
TANKS
Galvanized
Mild steel
WATER PRESSURE
The galvanizing process protect the steel from corrosion, granting a long life standard UNI EN 1179, lead percentage 100 times less than the maximal value
product. permitted by D.M. n.174 dated 06/04/2004. Cordivari galvanizing process does
TANKS
Thank to the high temperatures of the treatment, the galvanizing process helps not contain dangerous material, so to be certified for drinkable water use.
to get better performances.
Cordivari premises are equipped with a high-tech hot galvanizing system.
The tank is dipped in a melted zinc bath (99,99% pure) according to European
Cordivari Heat Exchanger , with tubes bent to the bottom, are able to heat the complete quantity of water in an homogenous way, also in the lower part of the calorifier.
This will ensure total production of the storaged of D.H.W. in the calorifier. (10%-15% more than standard heat exchangers). Maximal hygiene will be guaranteed.
risk of Legionellosis
bacterias diffusion
(Legionella pneumophila)
TECHNICAL
SUPPORT
STRAIGHT HEAT EXCHANGER: between 10% BENDED HEAT EXCHANGER: 100% volume will
- 15% of storage volume is not heated with be heated with relevant thermal efficiency and
relevant thermal inefficiencies and risk of D.H.W. healthiness increase.
Legionellosis bacterias diffusion.
297
THERMAL STRATIFICATION
Thermal stratification is a physical process in which an hot fluid naturally tends to position Heating delivery
itself higher than the cold one.
75° C
The fluid (water) is always moving, and tends to remix, therefore the natural process of 70° C
Efficient Thermal
stratification must be supported to maintain an increasing temperature gradient from 65° C stratification
bottom to upper part and avoid the mixing of liquid at different temperatures. 75°C
60° C
55° C
To allow stratification into the tanks means to create a remarkable difference in temperature 50° C
storaging volume from upper to lower part. With important positive effects in terms of
45° C
efficiency.
A proper stratificated storaging means to have quantities of hot water available in short 40° C Standard Thermal
time. 35° C stratification
Example of stratification: 30° C 30°C
Heat received during the day is accumulated in the higher part of the tank, reaching a 25° C
suitable temperature for end user, while in the lower part temperature remains cold and even 20° C
when solar collectors have a temperature below the one needed (afternoon-evening), the
heat exchanger continues and tanks is storaging further energy.
Stratification plate
Heating return
stratificator system
1 2 3 4 5 6
Sequence of thermographic images that show how a system works with the easy
stratification Buffer.
298
EXAMPLE OF INSTALLATION
EXTRA- BOLLY®
CALORIFIERS
INSTALLATION WITH BOLLY® 2 PDC AND SOLAR THERMAL SYSTEM
A Domestic cold water circuit inlet 4 Solar thermal panels 10 Electrical immersion
BOLLYTERM®
CALORIFIERS
C Radiators/heating therminals 6 Circulation and Mixed Pump module 12 D.H.W. recirculation group
STAINLESS STEEL
CALORIFIERS
C
CALORIFIERS FOR
E
HEAT PUMP
6 5
9 11
2
B
3 12
CYLINDERS - PUFFER
MULTIFUEL ENERGY
10
8
7
E
7
E
9 14 13
9
HYDRONIC
A
INERTIAL
TANKS
1 Safety Valve
2 Expansion vessel
3 Electronic valve (winter/summer)
4 VOLANO TERMICO
5 Circulation and Mixed Pump module
WATER PRESSURE
6 Heat pump
TANKS
4
B 3
E
COMPRESSED AIR
5
RECEIVERS
5 6
3
B
AND SPARE PARTS
E
3
ACCESORIES
E
A
TECHNICAL
1 2
SUPPORT
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
299
EXAMPLE OF INSTALLATION
INSTALLATION WITH PUFFER 1 CTS® (CONNECTION KIT) AND MACS® MODULE SYSTEM
A Domestic cold water circuit inlet 6 D.H.W. Recirculation
B Domestic hot water users 7 Hydraulic safety group 8
C Radiators/heating therminals 8 Solar panels
1 PUFFER 1 CTS ® connected 9 Solar system Solar circulation group
MACS ® module system for D.H.W.
2 Biomass energy source 10
production
3 Fireplace 11 Flow switch
4 Opened expansion vessel 12 2-way valve 4
5 Circulation group
11 B
12 12
9
6 3
1 1
10 10
5 13
A
5
7
INSTALLATION WITH PLATE-TO-PLATE HEAT EXCHANGERS AND SOLAR THERMAL SYSTEM FOR
POOL HEATING
1 Solar thermal system circulation group
3 Pump
5 Pool filter
6 Pool
7 Optional Generator
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
300
EXAMPLE OF INSTALLATION
EXTRA- BOLLY®
CALORIFIERS
INSTALLATION WITH BOLLYTERM HP®
A Domestic cold water circuit inlet
BOLLYTERM®
B Domestic hot water users
CALORIFIERS
12
C Recirculation
D Drain
1 BOLLYTERM® HP
C
Circulation group + expansion vessel
2
STAINLESS STEEL
Solar Thermal System
CALORIFIERS
3 Heat exchanger
6 5 4 Electrical immersion
5 Integrated heat pump
B 6 Solar panels
1
CALORIFIERS FOR
2
7 Heat pump heat Exchanger
HEAT PUMP
7
10 8
8 Magnesium anode + AnodenTester
A
3 9 Hydraulic safety group
9 11 10 Safety Valve
CYLINDERS - PUFFER
MULTIFUEL ENERGY
4 11 Expansion vessel
12 Recirculation
D
HYDRONIC
IMPIANTO CON PUFFERMAS®
A Domestic cold water circuit inlet 5 Circulation group
B Domestic hot water users 6 Hydraulic safety group
INERTIAL
TANKS
C To the heating system 7 Solar panels
1 Buffer tank PUFFERMAS ® 8 Solar circulation group
2 Gas/Gasoil Generator 9 MACS ® module 7
3 Biomass energy source 10 Recirculation (optional)
4 Opened expansion vessel
WATER PRESSURE
TANKS
6
A
4
COMPRESSED AIR
RECEIVERS
10 8
AND SPARE PARTS
1
ACCESORIES
9
5
5 C
3
5
TECHNICAL
SUPPORT
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
301
EXAMPLE OF INSTALLATION
7
1 Bolly ® 3 pdc C
2 Heat pump 8
3 Fireplace
4 Expansion vessel
9
5 Circulation group elettronico
8 Catcher/ Collector
3
9 Bypass solenoid valve
10 Thermostat mixer
11 Solar station
12 5
12 Motorized 3-way valve
2
A Domestic cold water circuit inlet
E Drain
E
7
E
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
302
EXAMPLE OF INSTALLATION
EXTRA- BOLLY®
CALORIFIERS
INSTALLATION WITH ECO COMBI 3
A Domestic cold water circuit inlet
BOLLYTERM®
CALORIFIERS
B Domestic hot water users
C Heating system
2 Gas/Gasoil Generator
STAINLESS STEEL
3 Biomass Generator
CALORIFIERS
4 Opened expansion vessel 4
7
5 Circulation group
7 Solar panels 8
8 Circulation group
CALORIFIERS FOR
HEAT PUMP
3
5
CYLINDERS - PUFFER
C
MULTIFUEL ENERGY
1 5
5
2
5 5
B
HYDRONIC
6
A
INERTIAL
8
TANKS
C
1
B
WATER PRESSURE
4 10 D
TANKS
6 4
1 PIASTRATERM® Accumulation tank
2 Generator
7 3 Expansion vessel
COMPRESSED AIR
4 Circulation group
RECEIVERS
9 Safety Valve
3 10 PIASTRATERM® Plate heat exchanger
A Domestic cold water circuit inlet
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
303
EXAMPLE OF INSTALLATION
S1
B
7
1 3
A
S3
5
6
2
M
S2
M
A Domestic cold water circuit inlet 2 Gas Generator S1 DHW recirculation group / Mixing
7
B Domestic hot water users 3 Hydraulic safety group S2 Professional gear case probe valve
C Radiators/heating therminals 4 Solar panels S3
13
2
11
7
12
C 1
5
8 10 3
11
A
6
A Domestic cold water circuit inlet 2 Gas generator 6 Hydraulic safety group 10 Automatic mixing valve
B Domestic hot water users 3 Biomass energy source 7 Solar panels 11 Hydronic modules
C Radiators/heating therminals 4 Thermostatic mixer 8 Solar system circulation group 12 Fireplace
1 PUFFERMAS ® CTS 1 POWER 5 Circulation group 9 MACS ® module for DHW production 13 Opened expansion vessel
The following schemes are purely illustrative. To realize the installation, always refer to a qualified design engineer.
304
EXTRA- BOLLY®
CALORIFIERS
HOT/COLD INSTALLATION WITH PUFFERMAS® 2 CTS AND CHILLED WATER ACCUMULATION TANK
BOLLYTERM®
CALORIFIERS
13
7
12
STAINLESS STEEL
CALORIFIERS
B
3
11 5 1
14
C C
5 8
CALORIFIERS FOR
D
2
HEAT PUMP
9
CYLINDERS - PUFFER
MULTIFUEL ENERGY
5 6
A 10
A Domestic cold water circuit inlet 1 PUFFERMAS ® 2 CTS 6 Hydraulic safety group 11 Circulation group
B Domestic hot water users 2 Gas generator 7 Solar panels 12 Fireplace
C Radiators/heating therminals 3 Biomass energy source 8 Solar circulation group 13 Opened expansion vessel
HYDRONIC
D Heating hydronic circuit 4 Heat pump 9 MACS ® module for DHW production 14 Chilled water accumulation tank
INERTIAL
TANKS
B
13
2
WATER PRESSURE
4
TANKS
11
7
12
C 1
COMPRESSED AIR
5
RECEIVERS
5
8 3
AND SPARE PARTS
ACCESORIES
A
6
A Domestic cold water circuit inlet 3 Biomass energy source 8 Solar circulation group
TECHNICAL
B Domestic hot water users 4 Thermostatic mixer 9 MACS ® module for DHW production
SUPPORT
7
C
B
D
3
1
5
6 1 Generator
9
2 Expansion vessel
3 Circulation group
4 Hydraulic safety group
2 3 3 3 5 PRS® module
6 Collector/Catcher
4 8
7 PUFFER (storage tank)
8 Safety Valve
A 9 Heat exchanger
A Domestic cold water circuit inlet
B Domestic hot water users
E
C To the heating system
D Recirculation
E Drain
C
B
D
3
1
5
1 Generator
6 2 Expansion vessel
9
3 Circulation group
4 Hydraulic safety group
5 PRS® module
3 6 Collector/Catcher
2 3 7 By-pass solenoid valve
8 Safety Valve
4 8
9 Heat exchanger
A Domestic cold water circuit inlet
A B Domestic hot water users
C To the heating system
D Recirculation
E E Drain
306
EXAMPLE OF INSTALLATION
EXTRA- BOLLY®
CALORIFIERS
INSTALLATION WITH STAINLESS STEEL BOLLY® 2 XL
BOLLYTERM®
CALORIFIERS
8
B
10
6
STAINLESS STEEL
1
CALORIFIERS
C
9 3
D
4
11
4 4
CALORIFIERS FOR
HEAT PUMP
7 2
5 9
3
CYLINDERS - PUFFER
MULTIFUEL ENERGY
A 4 3
1 Bolly 2 XL INOX 5 Hydraulic safety group 9 Safety Valve B Domestic hot water users
2 Heat pump 6 Solar panels 10 Thermostat mixer C To the heating system
3 Expansion vessel 7 Catcher/ Collector 11 Solar station D Recirculation
HYDRONIC
4 Circulation group 8 Bypass solenoid valve A Domestic cold water circuit inlet E Drain
INERTIAL
TANKS
6
WATER PRESSURE
TANKS
DOMESTIC WATER
ENTRY A
FLOW SENSOR D.H.W.
EXIT
RECIRCULATION B
1
COMPRESSED AIR
5
2
3
AND SPARE PARTS
ACCESORIES
A Domestic cold water circuit inlet 1 Storage tank 3 Solar System expansion vessel 5
SUPPORT
(MACS®)
B Domestic hot water user 2 Solar external exchange module 4 From/to generator 6 Solar panels
307
HEAT EXCHANGER OUTPUT CHARTS
EøãÙ Ö½çÝ ½ÊÙ®¥®ÙÝ «ã ø«Ä¦Ù ÊçãÖçã Ù¥ÙÙ ãÊ ãÃÖÙãçÙ Ä ¥½Êó Ùã Ê¥ ÖÙ®ÃÙù Ä ÝÊÄÙù υτ/ψω°
ã Ãø®Ãçà ó®ã«Ùó½ Ê¥ ÖÙÊ箽 «ó (çÖÖÙ ½®Ã®ã Ê¥ ã« çÙòÝ Ù¥ÙÙ ãÊ Ãø®Ãçà ÖÙ®ÃÙù ¥½Êó Ùã ®Ä ã« «ã
ø«Ä¦Ù, ó«®½ ã« ½ÊóÙ ½®Ã®ã ®Ä ã« çÙò Ù¥ÙÝ ãÊ ã« Ã®Ä®Ãçà ÖÙ®ÃÙù ¥½Êó Ùã).
60
2,63 m 2
50
EXTRA PLUS
CALORIFIERS RANGE
40
Output [kW]
1,58 m 2
30
0,94 m 2
20
0,76 m 2
10
0
55 60 65 70 75 80
Primary circuit temperature [°C]
200
180
EXTRA PLUS
160 CALORIFIERS RANGE
6,34 m 2
140
120 5,26 m 2
Output [kW]
100
4,54 m 2
80
3,17 m 2
60
40
20
0
55 60 65 70 75 80
Primary circuit temperature [°C]
308
HEAT EXCHANGER OUTPUT CHARTS
EXTRA- BOLLY®
CALORIFIERS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
BOLLYTERM®
CALORIFIERS
95
85
75
EXTRA CALORIFIERS
STAINLESS STEEL
CALORIFIERS
65 2 m2 RANGE
Output [kW]
55
45 1,5 m 2
CALORIFIERS FOR
HEAT PUMP
35
25
15
CYLINDERS - PUFFER
MULTIFUEL ENERGY
5
55 60 65 70 75 80
Extractable heat
1,5 m2 2 m2
exchanger surface
MAX MIN MAX MIN
Flow rate [m3/h]
HYDRONIC
6 3 10 5
INERTIAL
TANKS
95
85
75
WATER PRESSURE
Output [kW]
EXTRA CALORIFIERS
RANGE
TANKS
65
55
45
COMPRESSED AIR
RECEIVERS
35
1 m2
25
0,75 m 2
15
0,5 m 2
AND SPARE PARTS
ACCESORIES
5
55 60 65 70 75 80
Extractable heat
0,5 m2 0,75 m2 1 m2
exchanger surface
TECHNICAL
309
HEAT EXCHANGER OUTPUT CHARTS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE).
450
400
350
10 m 2 EXTRA CALORIFIERS
RANGE
Output [kW]
300
250
6 m2
200
150 4 m2
100
50
55 60 65 70 75 80
Extractable heat
4 m2 6 m2 10 m2
exchanger surface
MAX MIN MAX MIN MAX MIN
Flow rate [m3/h]
20 10 20 10 20 10
350
300
8 m2
250
EXTRA CALORIFIERS
RANGE
Output [kW]
200
5 m2
150
3 m2
100
50
0
55 60 65 70 75 80
Extractable heat
3 m2 5 m2 8 m2
exchanger surface
MAX MIN MAX MIN MAX MIN
Flow rate [m3/h]
15 7,5 20 10 20 10
310
HEAT EXCHANGER OUTPUT CHARTS
EXTRA- BOLLY®
CALORIFIERS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE).
BOLLYTERM®
100
CALORIFIERS
90
80 3,5 m 2
BOLLY® 1 ST
STAINLESS STEEL
CALORIFIERS
70
Output [kW]
60
50
CALORIFIERS FOR
HEAT PUMP
40
1,5 m 2
30
1,2 m 2
CYLINDERS - PUFFER
MULTIFUEL ENERGY
20
0,8 m 2
10
0,6 m 2
0
55 60 65 70 75 80
HYDRONIC
Primary circuit temperature [°C]
Fixed heat
0,6 m2 0,8 m2 1,2 m2 15 m2 3,5 m2
exchanger surface
MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN
Flow rate [m3/h]
2 1 2,5 1,25 3 1,5 3,5 1,75 6 3
INERTIAL
TANKS
120
100
WATER PRESSURE
BOLLY® 1 ST
TANKS
80
Output [kW]
COMPRESSED AIR
60 3,8 m 2
RECEIVERS
2,7 m 2
40
AND SPARE PARTS
1,8 m 2
ACCESORIES
20
0
55 60 65 70 75 80
TECHNICAL
SUPPORT
Fixed heat
1,8 m2 2,7 m2 3,7 m2
exchanger surface
MAX MIN MAX MIN MAX MIN
Flow rate [m3/h]
3,50 1,75 6 3 6 3
311
HEAT EXCHANGER OUTPUT CHARTS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
30
25
1 m2
20
0,75 m 2
BOLLY® 2 ST
Output [kW]
15
0,5 m 2
10
Fixed heat
0,4 m 2 exchanger 0,4 m2 0,5 m2 0,75 m2 1 m2
surface
5
Primary flow MAX MIN MAX MIN MAX MIN MAX MIN
rate
2 1 2,5 1,25 3 1,5 3,5 1,75
0
[m3/h]
55 60 65 70 75 80
70
60
50
BOLLY® 2 ST
Output [kW]
1,9 m 2
40
1,8 m 2
30
1,6 m 2
Fixed heat exchanger
1,6 m2 1,8 m2 1,9 m2
surface
20 Primary flow rate MAX MIN MAX MIN MAX MIN
[m3/h] 6 3 6 3 6 3
10
LOWER HEAT EXCHANGER TECHNICAL DATA - SEE BOLLY® 1 ST
55 60 65 70 75 80
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
70
60
50
BOLLY® 1 AP
Output [kW]
2,6 m 2
40
2 m2
30 1,8 m 2
312
HEAT EXCHANGER OUTPUT CHARTS
EXTRA- BOLLY®
CALORIFIERS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
BOLLYTERM®
CALORIFIERS
55
50
45
STAINLESS STEEL
40 BOLLY® 2 AP
CALORIFIERS
Output [kW]
2 m2
35
30
1,4 m 2
25
CALORIFIERS FOR
HEAT PUMP
20
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Primary circuit temperature [°C]
35
30
1,3 m 2 BOLLY® 2 AP
HYDRONIC
Output [kW]
25
20
0,9 m 2
15
INERTIAL
TANKS
Fixed heat exchanger surface 0,9 m2 1,3 m2
Primary flow rate MAX MIN MAX MIN
10
55 60 65 70 75 80 [m3/h] 3 1,5 3,5 1,75
WATER PRESSURE
TANKS
HEAT EXCHANGER OUTPUT REFERRED TO TEMPERATURE AND FLOW RATE OF PRIMARY CIRCUIT AND WITH SECONDARY AT 10/45°C AT MAXIMUM
WITHDRAWAL OF PRODUCIBLE DHW (UPPER LIMIT OF THE CURVES REFERRED TO MAXIMUM PRIMARY FLOW RATE IN THE HEAT EXCHANGER, WHILE
THE LOWER LIMIT IN THE CURVE REFERS TO THE MINIMUM PRIMARY FLOW RATE)
COMPRESSED AIR
RECEIVERS
140
120
5,4 m 2
100
AND SPARE PARTS
BOLLY® XL
Output [kW]
ACCESORIES
80
3,4 m 2
60
2 m2
40
Fixed heat
2 m2 3,4 m2 5,4 m2
20 exchanger surface
TECHNICAL
0
[m3/h] 2,5 1,25 3 1,5 3,5 1,75
55 60 65 70 75 80
313
COMPANY CERTIFICATES
Quality Certificate UNI EN ISO 9001 Environmental managing System Certificate UNI EN ISO 14001:2004
Main laws and regulations concerning production and installation of pressurised tanks:
UNI EN 12897:2016 - technical details for storage of sanitary hot water and indirect heating systems.
Law January 9th 1991, n. 10 – National energy plan, for energy saving and energy development for renewable energy source
D.L. 25/01/1992, n.108 – application of disposal n. 89/109/CEE concerning material and object destinated to get in touch with food products.
D.M. del 21/03/1973 – Decrete Law concening water for human consumption
D.M. 174 del 06/04/2004 Decrete Law concening water for human consumption
314
CERTIFICATES
EXTRA- BOLLY®
CALORIFIERS
BOLLYTERM®
CALORIFIERS
STAINLESS STEEL
CALORIFIERS
CALORIFIERS FOR
HEAT PUMP
CYLINDERS - PUFFER
MULTIFUEL ENERGY
CE certification in accordance with 2014/68/UE Pressure Equipement CE certification in accordance with requirements of 2014/68/UE
regulations relevant to pressure vessels Pressure Equipement regulations for pressurized tanks (equipped
HYDRONIC
pressure vessel)
INERTIAL
TANKS
WATER PRESSURE
TANKS
COMPRESSED AIR
RECEIVERS
AND SPARE PARTS
ACCESORIES
CE certification in accordance with requirements of 2014/68/UE Test certification of the silicone gaskets suitable for alimentary use
TECHNICAL
Pressure Equipement regulations for pressurized tanks (exchanging according to the D.M. n.174 del 2004.
SUPPORT
315
CERTIFICATES
Test report of internal treatment for food use Polywarm® in WRAS -Water Regulation Advisory Scheme certificate for Polywarm®
accordance with D.M. nr. 174 del 06/04/2004 granted by SSICA coating
Laboratory of Parma - Italy.
Certificate of Conformity for Polywarm® according to DVGW W270. Certificate of Comformity Polywarm according to UBA KTW.
316
CERTIFICATES
EXTRA- BOLLY®
CALORIFIERS
POLITECNICO DI MILANO
Dipartimento di Energia
RELAB- Renewable Heating and Cooling LAB
BOLLYTERM®
CALORIFIERS
LAB N° 1275
STAINLESS STEEL
Unità di
Quantità misurata Valore
misura
CALORIFIERS
Tempo di riscaldamento th 04:52:57 hh:mm:ss
Energia di riscaldamento assorbita Weh 2,48 kWh
Durata di un ciclo di attivazione-disattivazione tes 19:14:48 hh:mm:ss
Energia assorbita durante l’ultimo ciclo di attivazione-
Wes 0,49 kWh
disattivazione
Potenza assorbita in standby Pes 25,69 W
Prestazioni
Classe del ciclo di spillamento L
Energia termica utile PdC QTC 11,67 kWh
Periodo di tempo ciclo di prova tTTC 35:55:49 hh:mm:ss
CALORIFIERS FOR
Consumo energia elettrica per l’intero ciclo di prelievo WEL-M-TC 4,05 kWh
HEAT PUMP
En. termica calcolata prodotta tramite elettricità QEL-TC 0,18 kWh
Consumo totale energia elettrica per un ciclo di prelievo WEL-TC 3,92 kWh
Coefficiente di prestazione COPDHW 2,98 -
Temperatura di riferimento dell'acqua calda ș'WH 47,48 °C
Volume max acqua calda utilizzabile Vmax 208,15 l
Campo di esercizio
Temp. minima fonte di calore - °C
Temp. minima acqua calda sanitaria - °C
CYLINDERS - PUFFER
MULTIFUEL ENERGY
Temp. massima fonte di calore - °C
Temp. massima acqua calda sanitaria - °C
BOLLYTHERM® HP calorifier with heat pump performance test granted by BOLLYTHERM® HP calorifier with heat pump performance test granted
RELAB Energy Department (Politecnico of Milan) according to EN-16147 by IMQ CLIMA (Centro di Innovazione Tecnologica Agemont) according
HYDRONIC
related to Ecodesign ErP Directive 2009/125/CE – EU Regulation 812/2013- to EN-16147 related to Ecodesign ErP Directive 2009/125/CE – EU
814/2013. Regulation 812/2013-814/2013.
INERTIAL
TANKS
CORDIVARI S.r.l.
Zona Industriale Pagliare – 64020 MORRO D’ORO (TE) Italia
Tel. +39 085 80.40.1 r.a. - Fax UFF: COMM: +39 085 80.41.418 - Fax CENTR. +39 085 8041280
C.F. - P. IVA - REG. IMPRESE TE N. IT 00735570673 - R.E.A. TE N. 92310 – CAP. SOC. €.4.000.000,00 i.v.
www.cordivari.it – [email protected]
ZWWKZdK/WZKs
sZ/&/ /^WZ^/KE dZD/ / &/E/ >>͛d/,dddhZ EZ'd/ WZs/^d >
Z'K>DEdK ;hͿ E͘ ϴϭϰͬϮϬϭϯ >> KDD/^^/KE > Ϯ 'K^dK ϮϬϭϯ ZEd
WATER PRESSURE
DK>/d/WW>//KE>>/Zdd/sϮϬϬϵͬϭϮϱͬ>WZ>DEdKhZKWK>
KE^/'>/K /E DZ/dK >> ^W/&/, WZ > WZK'dd/KE KKDWd//> '>/
^>Yh/^ZdK/WZ>͛Yh>͘
TANKS
ZĂƉƉŽƌƚŽĚŝƉƌŽǀĂŶΣ KͲ>EϬϮ͘ϭϱ
ĂƚĂĚŝĞŵŝƐƐŝŽŶĞ ϮϭͬϬϴͬϮϬϭϱ
EΣĚŝƉĂŐŝŶĞƚŽƚĂůĞ ϳ
>ĂďŽƌĂƚŽƌŝŽĚŝƉƌŽǀĂ ŽƌĚŝǀĂƌŝ>
EŽŵĞĚĞůƌŝĐŚŝĞĚĞŶƚĞ ŽƌĚŝǀĂƌŝƐƌů
^ƉĞĐŝĨŝĐŚĞĚŝƉƌŽǀĂ EϭϱϯϯϮ͗ϮϬϬϳϱ͘ϰ
ĞƚĞƌŵŝŶĂƌĞůĂĚŝƐƉĞƌƐŝŽŶĞƚĞƌŵŝĐĂŶĞůůĞĐŽŶĚŝnjŝŽŶŝƉƌĞǀŝƐƚĞĚĂůůĂ
ŶŽƌŵĂĂůĨŝŶĞĚŝĐĂƌĂƚƚĞƌŝnjnjĂƌĞŝůƉƌŽĚŽƚƚŽŽŐŐĞƚƚŽĚĞůůĂƉƌŽǀĂ
^ĐŽƉŽĚĞůůĂƉƌŽǀĂ
ŶĞůů͛ĂŵďŝƚŽĚĞůůĞĐůĂƐƐŝĞŶĞƌŐĞƚŝĐŚĞƉƌĞǀŝƐƚĞĚĂůZĞŐŽůĂŵĞŶƚŽh
ϴϭϰͬϮϬϭϯ
COMPRESSED AIR
ŽůůŝƚŽƌĞ ;ƉƌĞƉĂƌĂƚŽƌĞ Ěŝ ĂĐƋƵĂ ĐĂůĚĂ ĂĚ ƵƐŽ ŝŐŝĞŶŝĐŽ ƐĂŶŝƚĂƌŝŽͿ ĂĚ
ĂĐĐƵŵƵůŽ ĐŽŶ ƐĐĂŵďŝĂƚŽƌĞ Ěŝ ĐĂůŽƌĞ ŝŶƚĞƌŶŽ ĨŝƐƐŽ͘ DĂƚĞƌŝĂůĞ ĚĞů
RECEIVERS
ACCESORIES
YƵĞƐƚŽƌĂƉƉŽƌƚŽŶŽŶƉƵžĞƐƐĞƌĞƌŝƉƌŽĚŽƚƚŽ͕ƐĞŶŽŶŝŶƚĞŐƌĂůŵĞŶƚĞ͕ƐĞŶnjĂů͛ĂƵƚŽƌŝnjnjĂnjŝŽŶĞĚĞůůĂďŽƌĂƚŽƌŝŽĚŝƉƌŽǀĂĐŚĞ
ůŽƌŝůĂƐĐŝĂ͘/ƌŝƐƵůƚĂƚŝĞƐƉŽƐƚŝŝŶƋƵĞƐƚŽƌĂƉƉŽƌƚŽĚŝƉƌŽǀĂƐŝƌŝĨĞƌŝƐĐŽŶŽĞƐĐůƵƐŝǀĂŵĞŶƚĞĂůů͛ŽŐŐĞƚƚŽƚĞƐƚĂƚŽ͘ŽƌĚŝǀĂƌŝ>
ŶŽŶĂƐƐƵŵĞŶĞƐƐƵŶĂƌĞƐƉŽŶƐĂďŝůŝƚăƉĞƌĚĂŶŶŝĚĞƌŝǀĂŶƚŝĚĂůů͛ŝŶƚĞƌƉƌĞƚĂnjŝŽŶĞĚĞŝĚĂƚŝĚĞůƉƌĞƐĞŶƚĞĚŽĐƵŵĞŶƚŽƌŝƉƌŽĚŽƚƚŽ
ĂůĚŝĨƵŽƌŝĚĞůƐƵŽĐŽŶƚĞƐƚŽ͘
Ϭ
ZĞǀŝƐŝŽŶĞ W͘/͘'ŝŽǀĂŶŶŝ͛ŐŝĚŝŽ /ŶŐ͘/ǀĂŶĂůĚŝŶŝ
ƐĞĐƵnjŝŽŶĞdĞƐƚ ŝƌĞnjŝŽŶĞdĞĐŶŝĐĂ
TECHNICAL
TÜV Rheinland test report about the quality of tests performed in BOLLY test report granted by “CORDIVARI LAB” according to EN-
SUPPORT
317
REGULATIONS FOR A CORRECT INSTALLATIONS OF PRESSURE TANKS
OVERPRESSURE PROTECTION:
If the sanitary water installation exceeds the admissible values of pressure of the calorifier, a pressure regulator as far away as possible from the calorifier has to be installed.
• Calorifier with primary circuits fluid with temperature below 110°C
To avoid damages on products due to sudden changes of pressure, it is always necessary to provide an expansion system, according to “Raccolta R ed. 2009 chapt. (R-1a)”.
For Water Heater with primary circuit temperature above to boiling secondary fluid at 0.5 bar pressure must have safety devices (termostat, pressurestat, level/min. pressure
protection). This expansion system can simply consist in a safety valve, counterwight, or spring-loaded, which port has to be a diameter in millimetres not lower than:
D min=
where V is Volume of Calorifier in liters, minimum diameter 15mm. The valve must be calibrated at a pressure not exceeding the maximum working pressure of the calorifier
and connected without any shut off device.
Besides the safety valve is however recommended to install a closed expansion vessel with atoxic membrane, in order to avoid a continuous opening of valve.
Cordivari Heat exchangers are manufactured in accordance with 97/23 CE directive and in reference to art. n. 3.3 of this directive they do not have to be marked CE
• Calorifiers with primary circuit supplied by fluid with temperature exceeding 110°C (steam or hot water)
For Water Heater with primary circuit temperature above to boiling secondary fluid at 0.5 bar pressure must have safety devices (termostat, pressurestat, level/min. pressure
protection).
Referring to primary circuit on Heat exchangers the provision on pressure working equipment shall be applied.
For provisions on systems with heat exchangers supplied by fluid with temperature exceeding 110°C with open and closed expansion vessel (such as control and safety device)
Please refer to chapt. “R.3.D. Racc. R ed. 2009”.
P x V ≤ 50 [bar x liter]
given the volume of fluid in the heat exchanger, is then possible to calculate with the above formula, the maximum permissible operating pressure for each heat exchanger
- surface of collectors does not exceed 50m2 and the potentiality is lower than the total usable at 35Kw
Above these limits, the exchanger (as well as the installation) is subject to requirements so as stated in provisions for in pressure working equipments (design, and plant testing
also when in operation, periodic restructuring) it is therefore necessary to use designed and tested exchangers according to 2014/68/UE Pressure Equipement.
CORROSION PROTECTION
To avoid electro-chemical corrosion - and in order to comply with the warranty’s conditions too - the cylinder has to be installed always with its cathode protection. Cordivari
Srl gives according to the tank version:
• Anoden-tester magnesium bar, which allows to check the real consumption of the magnesium bar just pushing on the “tester button”.
• Simpletest Anode (easy checking acting on the relative valve - any water outlet indicates the immediate substitution of the anode)
• Standard anode, where it is necessary the visual checking of the magnesium bar.
As accessory (only for Polywarm® version) also available the electronic anode which do not need to be replaced and need only an uninterrupted electricity. It is also necessary,
for warranty purposes too, that the water never exceeds the values indicated on DPR 236/88. To avoid any galvanic currents tank grounding have to be done.
LEGIONELLOSIS PROTECTION
Legionellosis can widespread with temperatures between 30°C and 45°C. To avoid any risk water tank has to be accumulated at 60°C and never reach temperature lower than
50°C.
Make sure that the premises, or technical rooms intended to contain the tanks are provided with sufficient openings to facilitate the passage of the tanks by considering overall
dimensions and avoiding therefore any necessity for demolitions both when installing and removing the tanks
For all cylinders with plate heat exchangers the hardness of the sanitary water inlet must be less than 30 ° f (French degrees).
It is necessary to install the storage tank / buffer tank providing appropriate and adequate drainage for any water leaks.
318
GENERAL SALES CONDITIONS AND WARRANTY
EXTRA- BOLLY®
CALORIFIERS
Sales of Cordivari’s products are made according to the conditions listed below. Exception should be agreed in written with Cordivari Srl.
1. Shipment
Goods are shipped at buyer’s (purchaser) risk and peril, even if transport is organized by Cordivari. Goods have to be checked at the delivery about unaltered packaging, missing or confused
BOLLYTERM®
items in the presence of the forwarder. Any claim has to be immediately communicated to the forwarder by appointing the shipment’s document and by registered mail within 8 days
CALORIFIERS
(otherwise the forwarder is cleared of his responsibilities).
2. Delivery terms
Delivery terms are indicative. Failure to comply with the agreed delivery terms for any reasons will not entitle the buyer (purchaser) to any compensation, cancellation or modification of the
order without our prior consent. In case of exceptional events like weather disaster, strikes or market shortage of raw materials not predictable, Cordivari will decide the best decision to
take. If the ordered goods will not be collected in the time agreed, this material will be invoiced and stored at buyer’s costs and risks.
STAINLESS STEEL
3. Weight, measures, surfaces
CALORIFIERS
Weights, measures, surfaces, shapes, sizes and other figures related to the products are merely indicative and Cordivari Srl may at any time modify them without any notice.
5. Warranty
On all Stainless Steel 316L cylinders the warranty granted by Cordivari Srl is 5 years
CALORIFIERS FOR
On all Polywarm® coating cylinders the warranty granted by Cordivari Srl is 5 years
HEAT PUMP
On all galvanized cylinders the warranty granted by Cordivari Srl is 2 years
For all exctractable and plate heat exchanger (plate-to-plate and brazed) either mounted on calorifiers or separately sold, Cordivari grants 2 years warranty.
For all Buffertanks Cordivari grants 2 years warranty
For buffertanks COMBI and ECO-COMBI, Cordivari grants 2 years warranty on heating water storage tanks and 5 years on Domestic Hot Water Parts.
Accessories and other items within the catalogue and not listed in currents Sales and Warranty Conditions (like the heat pump), warranty granted by Cordivari Srl is 2 years with the exclusion
of technical, electrical, electronic components for which the granted warranty is 12 months.
For special customized or other products for special projects the granted warranty by Cordivari srl is 2 years.
CYLINDERS - PUFFER
MULTIFUEL ENERGY
The warranty is valid for product defects, if all points of current article 5 are respected, and valid only if the products is set with the cathode protection in an efficient and permanent way.
This last one has to be frequently checked. The installation should respect the parameters in force about overpressure, corrosion, legionelosys according to the prescriptions previously
listed in this catalogue (See “Regulation for a correct installation of pressure tanks” section of current Catalogue). Basically the sanitary water productions units have to comply with the
national directive about water treatment.
The warranty is no more valid in case of non observance of local regulations.
Warranty will be applicable at the following conditions:
- Products must have been stored in good conditions and protected for the inclemency of the weather before installation
- Products did not have damages during transport, handling or installation.
- No alterations or reparations must be done without the prior consent of the seller
- The installation must have been done by authorized professionals and in conformity with all instructions and standards written on the technical data sheets provided by Cordivari Srl, and
HYDRONIC
according to eventual specific technical rules and general dispositon
- Accessories used must be original provided Cordivari materials
- The buyer must have paid all the bills within the pre-established deadlines
- No aggressive chemical substances must have been added to the water.
- Working pressure and temperature shown in the catalogue must correspond to the current usage pressure and temperature.
Those parts subject to natural consumption (as magnesium anode, gaskets, bolts) are always excluded for any warranty.
Warranty starts from Cordivari’s commercial invoice date and will be not renewed in case of product replacement
The warranty doesn’t cover construction or dismantling cost to move the product from/to the installation place.
INERTIAL
Cordivari srl is committed during the warranty period to refund the returned product if confirmed as to be defective.
TANKS
Besides, the purchaser may not claim any other costs of direct or indirect damage, to person / or properties resulting form above confirmed defects.
The materials that have to be replaced or repaired must be shipped free of carriage to the Cordivari plant.
Systems and products present on this catalogue are designed and realized according to European standards CE-EN-UNI-e PED. Systems and products follow these warranty and conformity
conditions only for countries where those laws are applicable. Cordivari has no responsibilities about warranty and conformity for extra UE countries or where these laws are not applicable.
6. Payments
WATER PRESSURE
All invoices have to be paid according to the agreed deadline. Any delay, even partially may suspend immediately the planned deliveries. Overdue interest could be charged at current rates.
TANKS
7. Goods’ property
Cordivari Srl remains owner of the delivered goods until they are not completely paid by the buyer (purchaser). In case of failure to proceed with the payment by the buyer (purchaser),
Cordivari Srl can ask for the immediate return of the delivered goods, keeping the partial paid amount as indemnity, or even ask for a bigger amount should the damage be higher.
8. Prices
Prices are not binding and can be modified without notice at anytime. Prices are revisable, in case of market conditions changes Cordivari srl reserve the right to modify them for goods
still to be delivered. Stated prices are ex-works Cordivari Plant in Morro D’oro (TE – Italy), except in case of written agreements. For some voluminous delivery Cordivari may charge some
COMPRESSED AIR
packing extra-costs.
RECEIVERS
9. Orders
The minimum order is Euro 2.000,00. Given orders are binding to the buyer, who acknowledges of all our sales conditions.
In case the client draws up the order in name and on behalf of others, with the signing of the order he is committed to the fulfillment of what agreed.
Delivery is only at the headquarters / warehouse of the Customer, for different deliveries please contact our sales office.
Additional costs may be asked to the buyer (purchaser) in case of special requests on delivery term (express delivery, etc.)
AND SPARE PARTS
ACCESORIES
11. Notes
Translation of Cordivari General sales conditions and warranty terms, reported in this page, has been done from the Italian version. In case of possible controversy, the official Cordivari
General sales condition and warranty terms are the one reported in the Italian language, stated at the following page of this catalogue.
All rights such as reproduction, diffusion and translation are reserved. Any part of this brochure can be reprinted or reproduced to any other form without a written authorization by Cordivari
Srl. The present catalogue substitutes and invalidates all previous editions. Cordivari reserves the right to modify in every moment products and figures reported in the catalogue and has
no responsibility for any press mistake.
319
CONDIZIONI GENERALI DI VENDITA E GARANZIA
Le vendite dei prodotti della Cordivari Srl sono effettuate conformemente alle sotto elencate Condizioni Generali di Vendita e Garanzia. Ogni deroga a queste condizioni è subordinata
all’accettazione scritta da parte della Cordivari Srl.
1. Spedizione
La merce viaggia a rischio e pericolo del Committente, anche se viene spedita franco destino. La merce deve essere verificata all’atto della consegna, controllando l’integrità dell’imballo,
articoli mancanti o sostituzioni in presenza del trasportatore. Ogni contestazione dovrà essere segnalata immediatamente al trasportatore/corriere firmando con riserva il DDT e
confermando tale riserva a mezzo lettera raccomandata o posta certificata entro otto giorni dal ricevimento merce.
2. Termini di Consegna
I termini di consegna si intendono puramente indicativi e comunque se il termine di consegna non potesse essere rispettato per qualsiasi motivo, il Committente non avrà diritto a esigere
alcun indennizzo, pagamenti di penali, annullamento o modifica all’ordine conferitoci. In caso di eventi straordinari quali calamità naturali, scioperi, mancanza di materie prime e cause di
forza maggiore, la Cordivari Srl si riserva la scelta delle misure da adottare. Se la merce ordinata non viene ritirata nel periodo concordato, questa verrà fatturata e immagazzinata con costi,
rischio e pericolo a carico del Committente.
5. Garanzia
Per tutti i bollitori in acciaio inox 316 L la Cordivari Srl garantisce anni 5.
Per tutti i bollitori con trattamento anticorrosivo interno in Polywarm® la Cordivari Srl garantisce anni 5.
Per tutti recipienti con trattamento anticorrosivo di zincatura a caldo la Cordivari Srl garantisce anni 2.
Per tutti gli scambiatori di calore estraibili e a piastre (ispezionabili e saldobrasati), sia montati sui bollitori sia venduti singolarmente la Cordivari Srl garantisce anni 2.
Per tutti i termoaccumulatori PUFFER e TERMOACCUMULATORI COMBINATI la Cordivari Srl garantisce anni 5 .
Per gli accessori e per gli articoli residuali del presente catalogo non contemplati nelle condizioni generali di vendita la Cordivari Srl garantisce anni 2 ad eccezione di componenti tecnici,
elettrici ed elettronici, dove la garanzia è di 12 mesi.
Per tutti gli articoli fuori standard, i prodotti speciali realizzati su specifica del Cliente, la Cordivari Srl garantisce anni 2.
I prodotti ed i sistemi presenti in questo catalogo sono progettati e realizzati in conformità alle direttive di riferimento CE-EN-UNI-e PED. La garanzia e la conformità di detti prodotti e
sistemi hanno valenza esclusivamente in quei paesi dove tali norme sono riconosciute e recepite. In paesi extra-europei o comunque in paesi che non recepiscono tali norme la Cordivari
non assume responsabilità per garanzia e conformità.
La garanzia copre i difetti di fabbricazione. Essa decade se non vengono rispettati i punti dell’art.5. Sussiste a condizione che l’installazione dei prodotti abbia rispettato i criteri della
protezione dalla sovrappressione, corrosione, legionella e norme e prescrizioni di installazione e utilizzo descritte nel presente catalogo e tutte le eventuali norme in materia impiantistica.
Negli impianti di produzione di acqua calda sanitaria, così come in quelli di riscaldamento, attenersi, ai fini della garanzia, a quanto disposto dalla norma UNI CTI 8065 che prevede vari tipi
di trattamenti dell’acqua in funzione delle sue caratteristiche. La garanzia non copre danni derivanti da inadempienze alle prescrizioni della norma UNI CTI 8065.
L’impegno di prestare la garanzia sussiste a condizione che:
Il prodotto sia stato immagazzinato in buone condizioni e al riparo dalle intemperie prima dell’installazione;
Il prodotto non abbia subito danneggiamenti durante il trasporto, le movimentazioni o l’installazione;
Non siano state compiute manomissioni o riparazioni da persone non autorizzate dalla Cordivari Srl;
L’installazione sia stata realizzata da personale autorizzato, in conformità alle istruzioni e alle norme indicate sulla documentazione tecnica fornita dalla Cordivari Srl e alle norme e
prescrizioni di installazione e utilizzo riportate nel presente catalogo e che siano state rispettate eventuali disposizioni di leggi o norme tecniche specifiche;
Gli accessori utilizzati siano quelli regolarmente forniti dalla Cordivari Srl;
Il compratore abbia effettuato il saldo dei pagamenti nei termini prestabiliti;
Non siano state eseguite aggiunte di sostanze chimiche aggressive all’acqua;
La pressione e la temperatura di esercizio indicate sul catalogo corrispondano alla pressione e alla temperatura limite di utilizzo.
Sono esclusi sempre da qualsiasi garanzia quei particolari soggetti a naturale usura (es. anodi, guarnizioni, bulloni ecc.).
La garanzia decorre dalla data della fattura di vendita della Cordivari Srl e non si rinnova in alcun caso nell’eventualità di una sostituzione del prodotto.
La garanzia non copre costi dovuti a demolizioni, lavori per il passaggio dei prodotti sia in ingresso che in uscita e la manodopera per eventuali sostituzioni di prodotto.
Cordivari Srl si impegna durante il periodo di garanzia alla sostituzione del prodotto reso riconosciuto difettoso per accertatati difetti di produzione, oltre a ciò il Committente non potrà
vantare alcun altro risarcimento per spese di danno, diretti o indiretti di qualsiasi natura a persone e/o a cose derivanti da detti difetti.
6. Pagamenti
I pagamenti delle fatture relative alle forniture dovranno essere effettuati entro i termini di scadenza stabiliti. Il ritardo nel pagamento delle fatture, anche se parziale, dà luogo alla
decorrenza degli interessi di mora nella misura del tasso corrente, oltre alla sospensione immediata delle spedizioni in corso e del processamento di eventuali ordini.
7. Riserva di proprietà
I prodotti restano di proprietà della Cordivari Srl fino al pagamento dell’l’ultima rata di Price di merce consegnata. In caso di inadempimento anche parziale del compratore la Cordivari Srl
potrà chiedere l’immediata restituzione della merce trattenendo comunque le rate pagate a titolo di indennità salvo il maggior danno.
8. Prezzi
I prezzi non sono impegnativi e possono essere modificati senza preavviso. I prezzi sono revisionabili in funzione delle variazioni che dovessero intervenire fino al momento della consegna.
I prezzi si intendono resa franco stabilimento di Morro D’Oro (TE), salvo diversi accordi.
I prezzi sono sempre riportati nel listino al netto di IVA.
For models ingombranti la Cordivari Srl si riserva di chiedere una partecipazione alle spese di imballaggio e trasporto.
9. Ordini/Consegna
Il valore minimo per ordine è di Euro 1.000; per ordini inferiori alla somma di Euro 1.000, contributo del 6% con addebito minimo di Euro 25,00. Gli ordini impartiti impegnano definitivamente
il Committente che deve dichiarare di conoscere e accettare tutte le condizioni di vendita. Nel caso in cui il Committente rediga l’ordine per nome e per conto e in nome di altri, con la firma
dell’ordine si impegna in solido all’adempimento di quanto da egli convenuto. La consegna si intende esclusivamente presso la sede/magazzino del Committente.
Richieste particolari del Committente come: consegne espresso, consegna diversa dalla sede/magazzino, etc. avranno costi addizionali che verranno comunicati di volta in volta mdal
nostro ufficio commerciale.
320
Mod. 03.10-E
DATE
COMPANY
NAME
DESCRIPTION
DRAWING
TECHNICAL DETAILS
CAPACITY [lt]
DIAMETER [mm]
HEIGHT [mm]
VERTICAL
HORIZONTAL
POLYWARM®
STAINLESS STEEL
PRESSURE TEMPERATURE
LIQUID PRESSURE ©COPYRIGHT: This form cannot not be forwarded of reproduced without written authorization issued by Cordivari Srl
LIQUID PRESSURE
QUANTITY
INSULATION
REMARKS
321
NOTES
322
NOTES
323
NOTES
324
NOTES
325
NOTES
326
NOTES
327
10/2017 - 6301381340052 EN
FOLLOW US
AHEEEHAPJHIPFEAAKGLNPPAHEEEHA
BNFFFNBPNGJDEKFPILJCBPBNFFFNB
NBCDOFFNKGKFFOKAEPCFIIJLJNFFK
NPLFKBFCNLPGDDMGADPAEFKLNADEA
KIBLPJFJKOIGCHEOOAKKFGMDGCMGP
ENFNFFEHKKEGLNIHDCFJAHFHADFMK
APBBBPAPIGDGIAMGHJOLGBGHCHHCF
HHHHHHHPPPPHPPHPPPHPHHPHPPPHP
WWW.CORDIVARI.COM
CORDIVARI srl - Z. I. Pagliare 64020 Morro D’Oro (TE) • Italy - C.F. / P.Iva e Reg. Imp. TE 00735570673 - Capitale Sociale Euro 4.000.000,00 i.v
Tel: +39 085 80.40.1 Fax: +39 0 85 80.40.273 - [email protected] • www.cordivari.com - UNI EN ISO 9001 • UNI EN ISO 14001:2014