0% found this document useful (0 votes)
57 views

Nozzle Performance Test Unit,: Computer Controlled With SCADA

This document provides information about a Computer Controlled Nozzle Performance Test Unit with SCADA capabilities. The unit allows students to study nozzle performance and consists of a pressure chamber, nozzle supports, and a force sensor. Nozzles can be interchanged rapidly. Sensors measure pressure, temperature, and air flow. The unit is supplied with control software and interfaces to remotely operate and collect data on nozzle tests.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views

Nozzle Performance Test Unit,: Computer Controlled With SCADA

This document provides information about a Computer Controlled Nozzle Performance Test Unit with SCADA capabilities. The unit allows students to study nozzle performance and consists of a pressure chamber, nozzle supports, and a force sensor. Nozzles can be interchanged rapidly. Sensors measure pressure, temperature, and air flow. The unit is supplied with control software and interfaces to remotely operate and collect data on nozzle tests.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Computer Controlled

Nozzle Performance Test Unit,


with SCADA
Technical Teaching Equipment
TFTC

Teaching
Technique
used
EDIBON SCADA System

2 3 4 Computer
(not included
Control Data Software for: in the supply)
Interface Box Acquisition - Computer Control
Board - Data Acquisition
- Data Management
1 5 Cables and Accessories
6 Manuals
Unit: TFTC. Nozzle Performance Test Unit
* Minimum supply always includes: 1 + 2 + 3 + 4 + 5 + 6
(Computer not included in the supply)

Key features:
Advanced Real-Time SCADA.

Open Control + Multicontrol + Real-Time Control. OPEN CONTROL


+
Specialized EDIBON Control Software based on Labview. MULTICONTROL
+
REAL TIME CONTROL
National Instruments Data Acquisition board (250 KS/s, kilo samples per second).

Calibration exercises, which are included, teach the user how to calibrate a sensor
and the importance of checking the accuracy of the sensors before taking
measurements.

Projector and/or electronic whiteboard compatibility allows the unit to be explained


and demonstrated to an entire class at one time.

Capable of doing applied research, real industrial simulation, training courses, etc.

Remote operation and control by the user and remote control for EDIBON technical
support, are always included.

Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).

Designed and manufactured under several quality standards.

Optional CAL software helps the user perform calculations and comprehend the www.edibon.com
Products
results. Products range
Units
This unit has been designed for future expansion and integration. A common 9.-Thermodynamics
expansion is the EDIBON Scada-Net (ESN) System which enables multiple students to & Thermotechnics
simultaneously operate many units in a network.

For more information about Key Features, click here:

ISO 9000: Quality Management European Union Certificate Certificates ISO 14000 and Worlddidac Quality Charter
(for Design, Manufacturing, (total safety) ECO-Management and Audit Scheme Certificate and
Commercialization and After-sales service) (environmental management) Worlddidac Member
Page 1
GENERAL DESCRIPTION
The Computer Controlled Nozzle Performance Test Unit (TFTC) has been specially designed to allow students to investigate and study the
performance of a nozzle (kinetic energy and thrust ).

Operating from a normal laboratory compressed air supply, the unit is supplied with one convergent and four convergent-divergent nozzles
that can be rapidly interchanged.

This test unit consists of a pressure chamber, with two supports for the nozzles, and a force sensor in its bottom support. Depending on how
the user wishes to work, the nozzle will be fixed to the bottom or to the top support. On the side in which the nozzle has not been fixed, the
user will put the lid on which the air will fall. This lid makes a system that allows the air to be separated from it as soon as the air has impacted
tangentially on the incidence direction, not on the anti-paralell direction to the incidence direction. Thus, the measured force will be only
the incident one, without any kind of reaction due to the “rebound” of the jet.

By means of a valves system the user will be able to obtain that the air comes into the chamber in its bottom or in its top part. Besides, the
pressure in the chamber will be controlled by a pressure control system.

Moreover, three temperature sensors are available, two at the chamber inlets and another one in the chamber. The pressure can be
measured at any moment at the chamber inlet and inside, whereas a sensor in its outlet calculates the air flow that comes out from the
chamber.

Finally, the impulse/reaction force made by the jet coming from the nozzle is measured by a force sensor.

This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a Control
Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and Management Software Packages, for controlling the
process and all parameters involved in the process.

PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION

OPEN CONTROL
+
MULTICONTROL
+
REAL TIME CONTROL

Page 2 www.edibon.com
COMPLETE TECHNICAL SPECIFICATIONS (for main items)
With this unit there are several options and possibilities:

- Main items: 1, 2, 3, 4, 5 and 6.

- Optional items: 7, 8, 9, 10, 11 and 12.

Let us describe first the main items (1 to 6):


1 TFTC. Unit:

Bench top unit.

Anodized aluminum structure and panels of painted steel.

Main metallic elements of stainless steel.

Diagram in the front panel with similar distribution to the elements


in the real unit.

Chamber of stainless steel:

Diameter: 200 mm. approx.

Height: 400 mm. approx.

Nozzles kit (5 nozzles) of 2 mm. of nominal throat. 1 convergent


nozzle (with ratio:1) and 4 convergent-divergent nozzles with
1.2, 1.4, 1.6 and 2 ratio, respectively.

2 Pressure sensors, one to measure the pressure at the chamber


inlet and other to measure the pressure in the chamber.
TFTC. Unit
2 Temperature sensors (”J” type) to measure temperatures at the
chamber inlets.

1 Temperature sensor (”J“ type) to measure temperature in the chamber.

Flow sensor (to measure air flow at the chamber outlet), range: 0-500 l./min.

Force sensor, range: 3.5 N.

Valves (open/closed) to direct the air.

Valve (adjustable), outlet of the chamber.

Inlet pressure regulation valve (air regulator: 0-10 bar) with humidity filter, where the compressed air supply
(compressor) will be connected.

Nozzles may be rapidly interchanged.

The complete unit includes as well:

Advanced Real-Time SCADA.

Open Control + Multicontrol + Real-Time Control.

Specialized EDIBON Control Software based on Labview.

National Instruments Data Acquisition board (250 KS/s , kilo samples per second).

Calibration exercises, which are included, teach the user how to calibrate a sensor and the
importance of checking the accuracy of the sensors before taking measurements.

Projector and/or electronic whiteboard compatibility allows the unit to be explained and
demonstrated to an entire class at one time.

Capable of doing applied research, real industrial simulation, training courses, etc.

Remote operation and control by the user and remote control for EDIBON technical support, are
always included.

Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).

Designed and manufactured under several quality standards.

Optional CAL software helps the user perform calculations and comprehend the results.

This unit has been designed for future expansion and integration. A common expansion is the
EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously operate
many units in a network.

Page 3 www.edibon.com
Complete Technical Specifications (for main items)
2 TFTC/CIB. Control Interface Box:
The Control Interface Box is part of the SCADA system.
Control interface box with process diagram in the front panel and with the same distribution that the
different elements located in the unit, for an easy understanding by the student.
All sensors, with their respective signals, are properly manipulated from -10V. to +10V. computer output.
Sensors connectors in the interface have different pines numbers (from 2 to 16), to avoid connection errors.
Single cable between the control interface box and computer.
The unit control elements are permanently computer controlled, without necessity of changes or
connections during the whole process test procedure.
Simultaneous visualization in the computer of all parameters involved in the process.
Calibration of all sensors involved in the process.
Real time curves representation about system responses.
Storage of all the process data and results in a file.
Graphic representation, in real time, of all the process/system responses.
All the actuators’ values can be changed at any time from the keyboard allowing the analysis about TFTC/CIB
curves and responses of the whole process.
All the actuators and sensors values and their responses are displayed on only one screen in the computer.
Shield and filtered signals to avoid external interferences.
Real time computer control with flexibility of modifications from the computer keyboard of the
parameters, at any moment during the process.
Real time computer control for pumps, compressors, resistances, control valves, etc.
Real time computer control for parameters involved in the process simultaneously.
Open control allowing modifications, at any moment and in real time, of parameters involved in the
process simultaneously.
Three safety levels, one mechanical in the unit, another electronic in the control interface and the
third one in the control software.
3 DAB. Data Acquisition Board:
The Data Acquisition board is part of the SCADA system.
PCI Express Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI
Express.
Analog input:
Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536.
Sampling rate up to: 250 KS/s (kilo samples per second).
Input range (V)=10 V. Data transfers=DMA, interrupts, programmed I/0. DMA channels=6.
Analog output:
DAB
Number of channels=2. Resolution=16 bits, 1 in 65536. Maximum output rate up to: 900 KS/s.
Output range(V)=10 V. Data transfers=DMA, interrupts, programmed I/0.
Digital Input/Output:
Number of channels=24 inputs/outputs. D0 or DI Sample Clock frequency: 0 to 100 MHz.
Timing: Number of Counter/timers=4. Resolution: Counter/timers: 32 bits.
4 TFTC/CCSOF. Computer Control +Data Acquisition+Data Management Software:
The three softwares are part of the SCADA system.
Compatible with actual Windows operating systems. Graphic and intuitive simulation of the process in
screen. Compatible with the industry standards.
Registration and visualization of all process variables in an automatic and simultaneous way.
Flexible, open and multicontrol software, developed with actual windows graphic systems, acting
simultaneously on all process parameters.
Management, processing, comparison and storage of data.
Sampling velocity up to 250 KS/s (kilo samples per second).
Calibration system for the sensors involved in the process.
It allows the registration of the alarms state and the graphic representation in real time. TFTC/CCSOF
Comparative analysis of the obtained data, after the process and modification of the conditions during the
process.
Open software, allowing the teacher to modify texts, instructions. Teacher’s and student’s
passwords to facilitate the teacher’s control on the student, and allowing the access to different work levels.
This unit allows the 30 students of the classroom to visualize simultaneously all the results and the
manipulation of the unit, during the process, by using a projector or an electronic whiteboard.
5 Cables and Accessories, for normal operation.
6 Manuals: This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface
and Control Software, Starting-up, Safety, Maintenance, Calibration & Practices Manuals.

* inReferences 1 to 6 are the main items: TFTC + TFTC/CIB + DAB + TFTC/CCSOF + Cables and Accessories + Manuals are included
the minimum supply for enabling normal and full operation.
Page 4 www.edibon.com
EXERCISES AND PRACTICAL POSSIBILITIES TO BE DONE WITH MAIN ITEMS
1.- Demonstration of the phenomenon of "choking". 15.- The Computer Control System with SCADA allows a real
industrial simulation.
2.- Determination of jet reaction and specific thrust at a variety of
inlet and back pressure. 16.- This unit is totally safe as uses mechanical, electrical and
electronic, and software safety devices.
3.- Determination of inlet pressure effect on mass flow rate, for a
given back pressure. 17.- This unit can be used for doing applied research.
4.- Comparison of actual mass flow rate with the theoretical value. 18.- This unit can be used for giving training courses to Industries
even to other Technical Education Institutions.
5.- Determination of the back pressure effect on the mass flow rate.
19.- Control of the TFTC unit process through the control interface
6.- Nozzle efficiency calculation. box without the computer.
7.- Determination of the jet velocity and the nozzle efficiency. 20.- Visualization of all the sensors values used in the TFTC unit
8.- Determination of the jet reaction and the specific pushing. process.

9.- Simple and classical method used to determine jet velocity. - By using PLC-PI additional 19 more exercises can be done.

10.- Measurement of mass flow rate and coefficient of discharge. - Several other exercises can be done and designed by the user.

11.- By means the sensors measurements we can get mass flow rate,
jet speed, efficiency and pushing for a variety of nozzles operating
for a wide range of pressure ratios.
Additional practical possibilities:
12.- Sensors calibration.
Other possibilities to be done with this Unit:
13.- Many students view results simultaneously.
To view all results in real time in the classroom by means of a
projector or an electronic whiteboard.
14.- Open Control, Multicontrol and Real Time Control.
This unit allows intrinsically and/or extrinsically to change the
span, gains; proportional, integral, derivate parameters; etc, in
real time.

REQUIRED SERVICES DIMENSIONS & WEIGHTS


-Electrical supply: single-phase, 220V./50Hz. or 110V./60Hz. TFTC:
-Compressed air (5 bar approx.) Unit: -Dimensions: 1000 x 700 x 600mm. approx.
-Computer (PC). (39.37 x 27.56 x 23.62 inches approx.)
-Weight: 60 Kg. approx.
(132 pounds approx.)
Control-Interface Box: -Dimensions: 490 x 330 x 310 mm. approx.
(19.29 x 12.99 x 12.20 inches approx.)
-Weight: 10 Kg. approx.
(22 pounds approx.)

Page 5 www.edibon.com
SOFTWARE MAIN SCREENS
SCADA
Main screen

I II

III IV

I Main software operation possibilities.


II Sensors displays, real time values, and extra output parameters. Sensors: ST= Temperature sensor. SP=Pressure sensor. SC=Flow sensor. SF=Force sensor.
III Channel selection and other plot parameters.
IV Real time graphics displays.

Software for Sensors Calibration


Example of screens

By using a free of charge code, the teacher and the students


can calibrate the unit.

The teacher can recover his/her own calibration by using the


EDIBON code that we give free of charge.

Page 6 www.edibon.com
SOME TYPICAL RESULTS

“CHOKING” PHENOMENON DEMONSTRATION


Nozzle I (covergent nozzle). Limit flow practice for input/output pressure ratio 0.5:

Nozzle II (covergent-divergent nozzle, with 1.2 ratio). Limit flow practice for input/output pressure ratio 0.6:

Page 7 www.edibon.com
Some typical results

Nozzle III (covergent-divergent nozzle, with 1.4 ratio). Limit flow practice for input/output pressure ratio 0.7:

Nozzle IV (covergent-divergent nozzle, with 1.6 ratio). Limit flow practice for input/output pressure ratio 0.8:

Page 8 www.edibon.com
Some typical results

Nozzle V (covergent-divergent nozzle, with 2 ratio). Limit flow practice for input/output pressure ratio 0.9:

Page 9 www.edibon.com
COMPLETE TECHNICAL SPECIFICATIONS (for optional items)
Additionally to the main items (1 to 6) described, we can offer, as optional, other items from 7 to 12.
All these items try to give more possibilities for:
a) Industrial configuration. (PLC)
b) Technical and Vocational Education configuration. (CAI and FSS)
c) Higher Education and/or Technical and Vocational Education configuration. (CAL)
d) Multipost Expansions options. (Mini ESN and ESN)
a) Industrial configuration
7 PLC. Industrial Control using PLC (it includes PLC-PI Module plus PLC-SOF Control Software):
-PLC-PI. PLC Module:
Metallic box.
Circuit diagram in the module front panel.
Front panel:
Digital inputs(X) and Digital outputs (Y) block:
16 Digital inputs, activated by switches and 16 LEDs for confirmation (red).
14 Digital outputs (through SCSI connector) with 14 LEDs for message (green).
Analog inputs block:
16 Analog inputs (-10 V. to + 10 V.) (through SCSI connector).
Analog outputs block:
4 Analog outputs (-10 V. to + 10 V.) (through SCSI connector).
Touch screen:
High visibility and multiple functions. Display of a highly visible status. Recipe function. Bar graph function. Flow display function. Alarm list.
Multi language function. True type fonts.
Back panel:
Power supply connector. Fuse 2A. RS-232 connector to PC. USB 2.0 connector to PC.
Inside:
Power supply outputs: 24 Vdc, 12 Vdc, -12 Vdc, 12 Vdc variable.
Panasonic PLC:
High-speed scan of 0.32 sec. for a basic instruction.
Program capacity of 32 Ksteps, with a sufficient comment area.
Power supply input (100 to 240 V AC).
DC input: 16 (24 V DC).
Relay output: 14.
High-speed counter.
Multi-point PID control.
Digital inputs/outputs and analog inputs/outputs Panasonic modules.
Communication RS232 wire to computer (PC).
Dimensions: 490 x 330 x 310 mm. approx. (19.29 x 12.99 x 12.20 inches approx.). Weight: 30 Kg. approx. (66 pounds approx.).
-TFTC/PLC-SOF. PLC Control Software:
For this particular unit, always included with PLC supply.
The software has been designed using Labview and it follows the unit operation procedure and linked with the Control Interface Box used in the Computer
Controlled Nozzle Performance Test Unit (TFTC).

Control Data Software for:


Interface Box Acquisition - Computer Control
Board - Data Acquisition
- Data Management
1

Unit
U it

PLC CONTROL
PLC-SOF.
Control Software

PLC-PI. PLC Module


Practices to be done with PLC-PI:
1.- Control of the TFTC unit process through the control interface box 10.- PLC inputs and outputs configuration.
without the computer. 11.- PLC configuration possibilities.
2.- Visualization of all the sensors values used in the TFTC unit process. 12.- PLC programming languages.
3.- Calibration of all sensors included in the TFTC unit process. 13.- PLC different programming standard languages.
4.- Hand on of all the actuators involved in the TFTC unit process. 14.- New configuration and development of new process.
5.- Realization of different experiments, in automatic way, without having in 15.- Hand on an established process.
front the unit. (This experiment can be decided previously).
16.- To visualize and see the results and to make comparisons with the TFTC
6.- Simulation of outside actions, in the cases hardware elements do not unit process.
exist. (Example: test of complementary tanks, complementary industrial
environment to the process to be studied, etc). 17.- Possibility of creating new process in relation with the TFTC unit.
7.- PLC hardware general use and manipulation. 18.- PLC Programming exercises.
8.- PLC process application for TFTC unit. 19.- Own PLC applications in accordance with teacher and student
requirements.
9.- PLC structure.
Page 10 www.edibon.com
Complete Technical Specifications (for optional items)
b) Technical and Vocational Education configuration

8 TFTC/CAI. Computer Aided Instruction Software System.


This complete software package includes two Softwares: the INS/SOF. Classroom Management Software (Instructor Software) and the TFTC/SOF. Computer
Aided Instruction Software (Student Software).
This software is optional and can be used additionally to items (1 to 6).
This complete software package consists of an Instructor Software (INS/SOF) totally integrated with the Student Software (TFTC/SOF). Both are
interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students.

- INS/SOF. Classroom Management Software (Instructor Software): Instructor Software


The Instructor can:
Organize Students by Classes and Groups.
Create easily new entries or delete them.
Create data bases with student information.
Analyze results and make statistical comparisons.
Generate and print reports.
Detect student’s progress and difficulties.
...and many other facilities.

- TFTC/SOF. Computer Aided Instruction Software (Student Software): Student Software


It explains how to use the unit, run the experiments and what to do at any
moment.
This Software contains:
Theory.
Exercises.
Guided Practices.
Exams.
For more information see CAI catalogue. Click on the following link:
www.edibon.com/products/catalogues/en/CAI.pdf

9 TFTC/FSS. Faults Simulation System.


Faults Simulation System (FSS) is a Software package that simulates
Example of some screens
several faults in any EDIBON Computer Controlled Unit. It is useful for Technical
and Vocational level.

The "FAULTS" mode consists on causing several faults in the unit normal
operation. The student must find them and solve them.

There are several kinds of faults that can be grouped in the following
sections:

Faults affecting the sensors measurement:

- An incorrect calibration is applied to them.

- Non-linearity.

Faults affecting the actuators:

- Actuators channels interchange at any time during the program


execution.

- Response reduction of an actuator.

Faults in the controls execution:

- Inversion of the performance in ON/OFF controls.

- Reduction or increase of the calculated total response.

- The action of some controls is annulled.

On/off faults:

- Several on/off faults can be included.

For more information see FSS catalogue. Click on the following link:
www.edibon.com/products/catalogues/en/FSS.pdf

Page 11 www.edibon.com
Complete Technical Specifications (for optional items)
c) Higher Education and/or Technical and Vocational Education configuration

10 TFTC/CAL. Computer Aided Learning Software (Results Calculation and Analysis).

This Computer Aided Learning Software (CAL) is a Windows based


software, simple and very easy to use, specifically developed by EDIBON. It is
very useful for Higher Education level.

CAL is a class assistant that helps in doing the necessary calculations to


extract the right conclusions from data obtained during the experimental
practices.

CAL computes the value of all the variables involved and performs the
Calculations
calculations. Information of constant values, unit conversion
factors and integral and derivative tables
It allows to plot and print the results. Within the plotting options, any
variable can be represented against any other.

Different plotting displays.

It has a wide range of information, such as constant values, unit conversion


factors and integral and derivative tables.

For more information see CAL catalogue. Click on the following link:
www.edibon.com/products/catalogues/en/CAL.pdf Plotting options

d) Multipost Expansions options

11 Mini ESN. EDIBON Mini Scada-Net System.


Mini ESN. EDIBON Mini Scada-Net System allows up to 30 students to work with a Mini ESN.
Teaching Unit in any laboratory, simultaneously. It is useful for both, Higher EDIBON Mini Scada-Net System
Education and/or Technical and Vocational Education.
The Mini ESN system consists on the adaptation of any EDIBON Computer
Controlled Unit with SCADA integrated in a local network.
1 UNIT =
This system allows to view/control the unit remotely, from any computer integrated up to 30 STUDENTS
can work
in the local net (in the classroom), through the main computer connected to the simultaneously
unit. Then, the number of possible users who can work with the same unit is higher
than in an usual way of working (usually only one).
Main characteristics:
- It allows up to 30 students to work simultaneously with the EDIBON
Nozzle Performance Test Unit (TFTC)
Computer Controlled Unit with SCADA, connected in a local net.
Computer Control
- Open Control + Multicontrol + Real Time Control + Multi Student Post. Control Software: Computer
Interface Control+Data
- Instructor controls and explains to all students at the same time. Box Acquisition+Data
Management
- Any user/student can work doing "real time" control/multicontrol and
visualisation.
Instructor’s
- Instructor can see in the computer what any user/student is doing in the Central Mini Scada-Net
30 Student Computer
Software
unit. Posts
- Continuous communication between the instructor and all the users/
LOCAL NET
students connected.
Main advantages:
- It allows an easier and quicker understanding. OPEN CONTROL
+ Note: The Mini ESN
- This system allows you can save time and cost. system can be used
MULTICONTROL
- Future expansions with more EDIBON Units. + with any EDIBON
REAL TIME CONTROL computer controlled
For more information see Mini ESN catalogue. Click on the following link:
+ unit.
MULTI STUDENT POST
www.edibon.com/products/catalogues/en/Mini-ESN.pdf

12 ESN. EDIBON Scada-Net System.


This unit can be integrated, in the future, into a Complete Laboratory with many Units and many Students.

For more information see ESN catalogue. Click on the following link:
www.edibon.com/products/catalogues/en/units/thermodynamicsthermotechnics/esn-thermodynamics/ESN-THERMODYNAMICS.pdf

Page 12 www.edibon.com
ORDER INFORMATION
Main items (always included in the supply) Optional items (supplied under specific order)
a) Industrial configuration
Minimum supply always includes: 7 PLC. Industrial Control using PLC (it includes PLC-PI Module plus PLC-SOF
Control Software):
1 Unit:TFTC. Nozzle Performance Test Unit.
- PCL-PI. PLC Module.
2 TFTC/CIB. Control Interface Box.
- TFTC/PLC-SOF. PLC Control Software.
3 DAB. Data Acquisition Board.
4 TFTC/CCSOF. Computer Control + Data Acquisition + Data b) Technical and Vocational configuration
Management Software.
8 TFTC/CAI. Computer Aided Instruction Software System.
5 Cables and Accessories, for normal operation. 9 TFTC/FSS. Faults Simulation System.
6 Manuals.
c) Higher Education and/or Technical and Vocational Education configuration
* IMPORTANT: Under TFTC we always supply all the elements for 10 TFTC/CAL. Computer Aided Learning Software (Results Calculation and
immediate running as 1, 2, 3, 4, 5 and 6. Analysis).
d) Multipost Expansions options
11 Mini ESN. EDIBON Mini Scada-Net System.
12 ESN. EDIBON Scada-Net System.

Page 13 www.edibon.com
TENDER SPECIFICATIONS (for main items)
1 TFTC. Unit:
Bench top unit.
Anodized aluminum structure and panels of painted steel.
Main metallic elements of stainless steel.
Diagram in the front panel with similar distribution to the elements in the real unit.
Chamber of stainless steel:
Diameter: 200 mm. approx.
Height: 400 mm. approx.
Nozzles kit (5 nozzles) of 2 mm. of nominal throat. 1 convergent nozzle (with ratio:1) and 4 convergent-divergent nozzles with 1.2, 1.4, 1.6 and 2 ratio,
respectively.
2 Pressure sensors, one to measure the pressure at the chamber inlet and other to measure the pressure in the chamber.
2 Temperature sensors (”J” type) to measure temperatures at the chamber inlets.
1 Temperature sensor (”J“ type) to measure temperature in the chamber.
Flow sensor (to measure air flow at the chamber outlet), range: 0-500 l./min.
Force sensor, range: 3.5 N.
Valves (open/closed) to direct the air.
Valve (adjustable), outlet of the chamber.
Inlet pressure regulation valve (air regulator: 0-10 bar) with humidity filter, where the compressed air supply (compressor) will be connected.
Nozzles may be rapidly interchanged.
The complete unit includes as well:
Advanced Real-Time SCADA.
Open Control + Multicontrol + Real-Time Control.
Specialized EDIBON Control Software based on Labview.
National Instruments Data Acquisition board (250 KS/s , kilo samples per second).
Calibration exercises, which are included, teach the user how to calibrate a sensor and the importance of checking the accuracy of the sensors before taking
measurements.
Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time.
Capable of doing applied research, real industrial simulation, training courses, etc.
Remote operation and control by the user and remote control for EDIBON technical support, are always included.
Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software).
Designed and manufactured under several quality standards.
Optional CAL software helps the user perform calculations and comprehend the results.
This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple
students to simultaneously operate many units in a network.
2 TFTC/CIB. Control Interface Box:
The Control Interface Box is part of the SCADA system.
Control interface box with process diagram in the front panel.
The unit control elements are permanently computer controlled.
Simultaneous visualization in the computer of all parameters involved in the process.
Calibration of all sensors involved in the process.
Real time curves representation about system responses.
All the actuators’ values can be changed at any time from the keyboard allowing the analysis about curves and responses of the whole process.
Shield and filtered signals to avoid external interferences.
Real time computer control with flexibility of modifications from the computer keyboard of the parameters, at any moment during the process. Real time computer
control for parameters involved in the process simultaneously.
Open control allowing modifications, at any moment and in real time, of parameters involved in the process simultaneously.
Three safety levels, one mechanical in the unit, another electronic in the control interface and the third one in the control software.
3 DAB. Data Acquisition Board:
The Data Acquisition board is part of the SCADA system.
PCI Express Data acquisition board (National Instruments) to be placed in a computer slot.
Analog input: Channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KS/s (kilo samples per second).
Analog output: Channels=2. Resolution=16 bits, 1 in 65536.
Digital Input/Output: Channels=24 inputs/outputs.
4 TFTC/CCSOF. Computer Control +Data Acquisition+Data Management Software:
The three softwares are part of the SCADA system.
Compatible with the industry standards.
Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters.
Management, processing, comparison and storage of data. Sampling velocity up to 250 KS/s (kilo samples per second).
Calibration system for the sensors involved in the process.
It allows the registration of the alarms state and the graphic representation in real time.
Open software, allowing the teacher to modify texts, instructions. Teacher’s and student’s passwords to facilitate the teacher’s control on the student, and
allowing the access to different work levels.
This unit allows the 30 students of the classroom to visualize simultaneously all the results and the manipulation of the unit, during the process, by using a
projector or an electronic whiteboard.
5 Cables and Accessories, for normal operation.
6 Manuals: This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface and Control Software, Starting-up, Safety, Maintenance,
Calibration & Practices Manuals.
Page 14 www.edibon.com
Tender Specifications (for main items)

Exercises and Practical Possibilities to be done with Main Items

1.- Demonstration of the phenomenon of "choking".


2.- Determination of jet reaction and specific thrust at a variety of inlet and back pressure.
3.- Determination of inlet pressure effect on mass flow rate, for a given back pressure.
4.- Comparison of actual mass flow rate with the theoretical value.
5.- Determination of the back pressure effect on the mass flow rate.
6.- Nozzle efficiency calculation.
7.- Determination of the jet velocity and the nozzle efficiency.
8.- Determination of the jet reaction and the specific pushing.
9.- Simple and classical method used to determine jet velocity.
10.- Measurement of mass flow rate and coefficient of discharge.
11.- By means the sensors measurements we can get mass flow rate, jet speed, efficiency and pushing for a variety of nozzles operating for a wide range of pressure
ratios.
Additional practical possibilities:
12.- Sensors calibration.
Other possibilities to be done with this Unit:
13.- Many students view results simultaneously.
To view all results in real time in the classroom by means of a projector or an electronic whiteboard.
14.- Open Control, Multicontrol and Real Time Control.
This unit allows intrinsically and/or extrinsically to change the span, gains; proportional, integral, derivate parameters; etc, in real time.
15.- The Computer Control System with SCADA allows a real industrial simulation.
16.- This unit is totally safe as uses mechanical, electrical and electronic, and software safety devices.
17.- This unit can be used for doing applied research.
18.- This unit can be used for giving training courses to Industries even to other Technical Education Institutions.
19.- Control of the TFTC unit process through the control interface box without the computer.
20.- Visualization of all the sensors values used in the TFTC unit process.
- By using PLC-PI additional 19 more exercises can be done.
- Several other exercises can be done and designed by the user.

Page 15 www.edibon.com
TENDER SPECIFICATIONS (for optional items)
a) Industrial configuration
7 PLC. Industrial Control using PLC (it includes PLC-PI Module plus PLC-SOF Control Software):
-PLC-PI. PLC Module:
Metallic box.
Circuit diagram in the module front panel.
Digital inputs(X) and Digital outputs (Y) block: 16 Digital inputs. 14 Digital outputs.
Analog inputs block: 16 Analog inputs.
Analog outputs block: 4 Analog outputs.
Touch screen.
Panasonic PLC:
High-speed scan of 0.32 sec. Program capacity of 32 Ksteps. High-speed counter. Multi-point PID control.
Digital inputs/outputs and analog inputs/outputs Panasonic modules.
-TFTC/PLC-SOF. PLC Control Software:
For this particular unit, always included with PLC supply.
Practices to be done with PLC-PI:
1.- Control of the TFTC unit process through the control interface box without the computer.
2.- Visualization of all the sensors values used in the TFTC unit process.
3.- Calibration of all sensors included in the TFTC unit process.
4.- Hand on of all the actuators involved in the TFTC unit process.
5.- Realization of different experiments, in automatic way, without having in front the unit. (This experiment can be decided previously).
6.- Simulation of outside actions, in the cases hardware elements do not exist. (Example: test of complementary tanks, complementary industrial
environment to the process to be studied, etc).
7.- PLC hardware general use and manipulation.
8.- PLC process application for TFTC unit.
9.- PLC structure.
10.- PLC inputs and outputs configuration.
11.- PLC configuration possibilities.
12.- PLC programming languages.
13.- PLC different programming standard languages.
14.- New configuration and development of new process.
15.- Hand on an established process.
16.- To visualize and see the results and to make comparisons with the TFTC unit process.
17.- Possibility of creating new process in relation with the TFTC unit.
18.- PLC Programming exercises.
19.- Own PLC applications in accordance with teacher and student requirements.

b) Technical and Vocational Education configuration


8 TFTC/CAI. Computer Aided Instruction Software System.
This complete software package consists of an Instructor Software (INS/SOF) totally integrated with the Student Software (TFTC/SOF).
-INS/SOF. Classroom Management Software (Instructor Software):
The Instructor can:
Organize Students by Classes and Groups.
Create easily new entries or delete them.
Create data bases with student information.
Analyze results and make statistical comparisons.
Generate and print reports.
Detect student’s progress and difficulties.
-TFTC/SOF. Computer Aided Instruction Software (Student Software):
It explains how to use the unit, run the experiments and what to do at any moment.
This Software contains:
Theory.
Exercises.
Guided Practices.
Exams.
9 TFTC/FSS. Faults Simulation System.
Faults Simulation System (FSS) is a Software package that simulates several faults in any EDIBON Computer Controlled Unit.
The "FAULTS" mode consists on causing several faults in the unit normal operation. The student must find them and solve them.
There are several kinds of faults that can be grouped in the following sections:
Faults affecting the sensors measurement:
- An incorrect calibration is applied to them.
- Non-linearity.
Faults affecting the actuators:
- Actuators channels interchange at any time during the program execution.
- Response reduction of an actuator.
Faults in the controls execution:
- Inversion of the performance in ON/OFF controls.
- Reduction or increase of the calculated total response.
- The action of some controls is annulled.
On/off faults:
- Several on/off faults can be included.

Page 16 www.edibon.com
Tender Specifications (for optional items)
c) Higher Education and/or Technical and Vocational Education configuration
10 TFTC/CAL. Computer Aided Learning Software (Results Calculation and Analysis).
This Computer Aided Learning Software (CAL) is a Windows based software, simple and very easy to use.
CAL is a class assistant that helps in doing the necessary calculations to extract the right conclusions from data obtained during the experimental practices.
CAL computes the value of all the variables involved and performs the calculations.
It allows to plot and print the results. Within the plotting options, any variable can be represented against any other.
Different plotting displays.
It has a wide range of information, such as constant values, unit conversion factors and integral and derivative tables.

d) Multipost Expansions options


11 Mini ESN. EDIBON Mini Scada-Net System.
EDIBON Mini Scada-Net System allows up to 30 students to work with a Teaching Unit in any laboratory, simultaneously.
The Mini ESN system consists on the adaptation of any EDIBON Computer Controlled Unit with SCADA integrated in a local network.
This system allows to view/control the unit remotely, from any computer integrated in the local net (in the classroom), through the main computer connected to
the unit.
Main characteristics:
-It allows up to 30 students to work simultaneously with the EDIBON Computer Controlled Unit with SCADA, connected in a local net.
-Open Control + Multicontrol + Real Time Control + Multi Student Post.
-Instructor controls and explains to all students at the same time.
-Any user/student can work doing "real time" control/multicontrol and visualisation.
-Instructor can see in the computer what any user/student is doing in the unit.
-Continuous communication between the instructor and all the users/students connected.
Main advantages:
-It allows an easier and quicker understanding.
-This system allows you can save time and cost.
-Future expansions with more EDIBON Units.
The system basically will consist of:
This system is used with a Computer Controlled Unit.
-Instructor’s computer.
-Students’ computers.
-Local Network.
-Unit-Control Interface adaptation.
-Unit Software adaptation.
-Webcam.
-Mini ESN Software to control the whole system.
-Cables and accessories required for a normal operation.

*Specifications subject to change without previous notice, due to the convenience of improvements of the product.
REPRESENTATIVE:

C/ Del Agua, 14. Polígono Industrial San José de Valderas.


28918 LEGANÉS. (Madrid). SPAIN.
Phone: 34-91-6199363 FAX: 34-91-6198647
E-mail: [email protected] WEB site: www.edibon.com

Issue: ED01/14
Date: December/2014

Page 17