This document provides instructions for measuring DC voltage and resistance using a clamp-on hi-tester device. It lists the names and functions of the device's parts, including the display, clamp sensor, operation grip, and function switch. The instructions describe setting the function switch to the voltage or resistance setting, connecting the test leads to the object being measured, and reading the display value. Safety cautions are also provided about operating conditions to prevent damage to the device.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
94 views1 page
3280 10 Value Doc 2 PDF
This document provides instructions for measuring DC voltage and resistance using a clamp-on hi-tester device. It lists the names and functions of the device's parts, including the display, clamp sensor, operation grip, and function switch. The instructions describe setting the function switch to the voltage or resistance setting, connecting the test leads to the object being measured, and reading the display value. Safety cautions are also provided about operating conditions to prevent damage to the device.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
CAUTION Names and Functions of Parts Measuring DC Voltage ( V)
Plug the test leads into the connector. Battery 2.
Do not store or use the instrument where it could be exposed to direct sunlight, high temperature or humidity, or condensation. Under such conditions, the instrument may 1. Display 1. Set the function switch to V. 3. be damaged and insulation may deteriorate so that it no longer meets specifications. 2. Clamp sensor 2. 10. 2. Connect the test leads to the object to be 3. Operation grip measured. Black (-) 9. test lead 4. Function switch 3. Read the display. 3280-10 23 Accuracy 5 (73 9 ), 80%RH or less, no condensation. OFF / AC current ( A) / AC voltage ( V) / DC voltage ( V) / Resistance 3. NOTE: Reversing the polarity of the leads displays a negative value. 1. Red (+) test lead Accuracy is guaranteed for input falling within 10% to 100% of each respective range. and Continuity check (Ω/ ) 3. CLAMP ON HiTESTER AC measurement: mean value measurement Function Range Accuracy* Max. input 5. Ω SAMP. F/S key Measuring AC current or AC or DC 1. Connect the test leads to Resistance Measurement Plug the test leads into the connector. (Ω) Resistor current voltage Display: INSTRUCTION MANUAL ACA 42.00 A 1.5% rdg. 5 dgt. 2000 A rms Switches display update rate Measurement value 5. 6. the object to be 1. Set the function switch to Ω/ . 2. Connect the test leads to the object to be 3. 2. 420.0 A (FAST/SLOW). Units measured. ( A) (Frequency range 50 - 60 Hz) continuous measured. November 2006 Revised edition 12 Printed in Japan 1000 A If the display value is fluctuating and Symbols hard to read, switch to the slow 3. Read the display. Effect of conductor position: 5.0% (in any direction from sensor center) Decimal point 3280C980-12 06-11H Maximum rated voltage to earth: CAT III 600 V (Current measurement section) update (SLOW: approximately every 1. Test 3 seconds) to stabilize the display. leads Measuring resistance or continuity 4. Max. input Switches between resistance Introduction Function Range Accuracy* Input impedance voltage measurement (Ω) and continuity Continuity Test ( ) Thank you for purchasing the HIOKI 3280-10 CLAMP ON HiTESTER. 4.200 V 11 MΩ 5% testing ( ). 7. ACV 2.3% rdg. 8 dgt. Plug the test leads into the connector. To obtain maximum performance from the instrument, please read this manual first, and 42.00 V 10 MΩ 5% 6. HOLD key Cord (Frequency range 600 V rms Battery cover (rear) 1. Set the function switch to Ω/ . keep it handy for future reference. ( V) 420.0 V 50 - 500 Hz) 10 MΩ 5% Press this to hold the display value 8. 3. 600 V 10 MΩ 5% (the indication appears). Press 2. Press the Ω key, so that the indication appears. 2. Inspection DCV 420.0 mV 4.200 V 100 MΩ 11 MΩ or over 5% once more to cancel the hold 3. Connect the test leads to the object to be 42.00 V 1.3% rdg. 4 dgt. 10 MΩ 5% 600 V DC function. 1. When you receive the instrument, inspect it carefully to ensure that no damage occurred ( V) 420.0 V 10 MΩ 5% 7. Connector 8. Plug measured. during shipping. If damage is evident, or if it fails to operate according to the 600 V 10 MΩ 5% Connect the test lead plug to the connector for voltage measurement, resistance Conductivity is good when the buzzer specifications, contact your dealer or Hioki representative. sounds. Test Maximum rated voltage to earth: CAT III 300 V, CAT II 600 V (Voltage measurement measurement, or continuity testing. Align the slot on the plug with the key in the leads connector. Safety section) 9. Red test lead (+) 10. Black test lead (-) Maintenance DANGER Overload Measurement Procedures This instrument is designed to conform to IEC 61010 Safety Standards, and has been Function Range Accuracy* Open terminal voltage protection CAUTION 420.0 Ω 2.0% rdg. 4 dgt. 3.4 V or less Pre-Operation Inspection (Check the following before using the If the protective functions of the instrument are damaged, either remove it from thoroughly tested for safety prior to shipment. However, mishandling during use could service or mark it clearly so that others do not use it inadvertently. result in injury or death, as well as damage to the instrument. Be certain that you 4.200 Resistance 42.00 kΩ 2.0% rdg. 4 dgt. 0.7 V (typ.) 3.4 V or less instrument.) kΩ 2.0% rdg. 4 dgt. 0.47 V (typ.) 3.4 V or less To clean the instrument, wipe it gently with a soft cloth moistened with water or mild understand the instructions and precautions in the manual before use. We disclaim 420.0 kΩ 2.0% rdg. 4 dgt. 0.47 V (typ.) 3.4 V or less 250 V rms The cladding of the test lead shall not be torn, and the metal shall not be exposed. (If [Ω] damage has occurred, replace with the specified test lead [Model 9208]. Failure to do detergent. Never use solvents such as benzene, alcohol, acetone, ether, ketones, any responsibility for accidents or injuries not resulting directly from instrument defects. 4.200 MΩ 5.0% rdg. 4 dgt. 0.47 V (typ.) 3.4 V or less 42.00 MΩ 10.0% rdg. 4 dgt. 0.47 V (typ.) 3.4 V or less so may result in electric shock.) thinners or gasoline, as they can deform and discolor the case. Measurement categories (Overvoltage categories) 2.0% rdg. 6 dgt. The clamp sensor or the case shall be free of damage. (If damage has occurred, To avoid corrosion from battery leakage, remove the batteries from the instrument if Continuity it is to be stored for a long time. The current measurement section conforms to CAT III 600 V safety requirements, and the 420.0 Ω (Threshold level 3.4 V or less 250 V rms avoid using the instrument. Use of the instrument under these conditions may result in [ ] 50 Ω 30 Ω ) If the instrument seems to be malfunctioning, confirm that the battery is not voltage measurement section conforms to CAT III 300 V, CAT II 600V requirements. electric shock.) To ensure safe operation of measurement instruments, IEC 61010 establishes safety *: rdg. (reading or displayed value), dgt. (resolution) The mating portions of the clamp sensor shall mate properly. The mating portions of discharged, and that the test leads are not open circuited before contacting your standards for various electrical environments, categorized as CAT I to CAT IV, and called the clamp sensor should also be free of any scratches or cracks. dealer or Hioki representative. Pack the instrument carefully so that it will not be damaged during shipment, and include a detailed written description of the problem. measurement categories. These are defined as follows. Specification Battery power should be near full capacity when power is turned on. (If the battery is Hioki cannot be responsible for damage that occurs during shipment. CAT I : Secondary electrical circuits connected to an AC electrical outlet through a near exhaustion, the indicator " " will light up. Using a battery close to exhaustion transformer or similar device. may result in incorrect measurements.) LCD panel 4199 maximum display value The reading should be around 0 A using the current function when no measurements Replacing Battery CAT II : Primary electrical circuits in equipment connected to an AC electrical outlet by a Out of range indication OF or -OF power cord (portable tools, household appliances, etc.) are being made. CAT III : Primary electrical circuits of heavy equipment (fixed installations) connected directly Battery low warning The reading should be around 0 V using the voltage function while short-circuiting the WARNING Data hold indication If the instrument is connected to a line that is to be measured, dangerous voltage to the distribution panel, and feeders from the distribution panel to outlets. test lead. Zero suppression 5 count or less (current measurement only) The reading should be around 0 Ω using the resistance function while short-circuiting levels may be applied to the terminals, and removing the case may expose live CAT IV : The circuit from the service drop to the service entrance, and to the power meter Display update rate FAST 400 ms 25 ms components. and primary overcurrent protection device (distribution panel). the test leads. SLOW 3.2 s 0.2 s To avoid electric shock when replacing the battery, first disconnect the test leads Higher-numbered categories correspond to electrical Range switching Auto range / Manual range from the object being measured. Also, after replacing the battery, always replace the environments with greater momentary energy, so a Withstand voltage 3536 VrmsAC sine wave (for 15 seconds ) between case and circuit DANGER cover and tighten the screw before using the instrument. measurement instrument designed for CAT III 5312 VrmsAC sine wave (for 15 seconds ) between clamp sensor and case Observe the following precautions to avoid electric shock. 5312 VrmsAC sine wave (for 15 seconds ) between clamp sensor and circuit Always verify the appropriate setting of the function selector before connecting the Use only CR2032 (Panasonic or MAXELL) lithium battery. Use of any other battery environments can endure greater momentary energy Location for use Altitude up to 2000 m (6562 feet), indoors test leads. Disconnect the test leads from the measurement object before switching may result in explosion. than one designed for CAT II. Using a measurement Maximum conductor φ 33 mm (1.30") or less the function selector. When replacing the battery, be sure to insert them with the correct polarity. instrument in an environment designated with a higher- diameter for measurement Never apply voltage to test leads when the Resistance, Continuity Check functions Otherwise, poor performance or damage from battery leakage could result. numbered category than that for which the instrument is Temperature and humidity 0 to 40 (32 to 104 ), 80%RH max (no condensation) are selected. Doing so may damage the instrument and result in personal injury. To Battery may explode if mistreated. Do not short-circuit, recharge, disassemble or for guaranteed accuracy avoid electrical accidents, remove power from the circuit before measuring. dispose of in fire. Handle and dispose of batteries in accordance with local rated could result in a severe accident, and must be Guaranteed accuracy period 1 year, or opening and closing of the Clamp sensor 10,000 times, Test leads and this instrument should only be connected to the secondary side of a regulations. carefully avoided. whichever comes first Never use a CAT I measuring instrument in CAT II, III, or IV environments. breaker, so the breaker can prevent an accident if a short circuit occurs. Keep batteries away from children to prevent accidental swallowing. Operating temperature and 0 to 40 (32 to 104 ), 80%RH max (no condensation) humidity Connections should never be made to the primary side of a breaker, because The measurement categories comply with the Overvoltage Categories of the IEC60664 Standards. unrestricted current flow could cause a serious accident if a short circuit occurs. NOTE: When the battery is exhausted, the indication Storage temperature -10 to 50 (14 to 122 ) (no condensation) appears in the display. Safety Symbols Temperature characteristics In 0 to 40 (32 to 104 ) range: 0.1 x Measurement accuracy / ( ) NOTE: Please note that waveforms that include elements outside the frequency 1. Remove the test leads from the test item, and power the Battery cover Power supply Rated supply voltage 3 V DC x 1 CR2032 x 1 Lithium battery characteristic range may not be measured correctly. This manual contains information and warnings essential for safe operation of the Maximum rated power 15 mVA instrument off. Accurate measurement may be impossible in the presence of strong magnetic 2. Remove the instrument from the case, and remove the instrument and for maintaining it in safe operating condition. Before using the Continuous operating time Approx. 150 hours (standard), Approx. 80 hours min. (in AC current fields, such as near transformers and high-current conductors, or in the Battery instrument, be sure to carefully read the following safety notes. measurement mode, continuous, no load) screws on the battery cover. presence of strong electromagnetic fields such as near radio transmitters. 3. Remove the used battery. Dimensions and mass Approx. 57W x 175H x 16D mm, approx. 100 g The symbol printed on the instrument indicates that the user should refer to a corresponding topic in the manual (marked with the symbol) (Approx. 2.24"W x 6.89"H x 0.63"D, approx. 3.5 oz.) AC Current Measurement ( A) 4. Being careful about the polarity, insert the new battery of Drop proof One meter to concrete the specified type. (CR2032 lithium battery:Panasonic or before using the relevant function. MAXELL) In the manual, the symbol indicates particularly important information Accessories Options Instruction Manual, 9398 CARRYING CASE, 9208 TEST LEADS 9209 TEST LEADS HOLDER DANGER 5. Replace the battery cover and fasten the screws. that the user should read before using the instrument. To avoid short circuits and potentially life-threatening hazards, never attach the Applicable standardsSafety: EN61010 instrument in current measurement mode to a circuit that operates at more than the NOTE: The battery included with this instrument was Indicates a double-insulated device. Current measurement section: Measurement category CAT III 600 V, inserted for TESTING PURPOSES ONLY. Battery life will vary. Please replace Indicates DC (Direct Current). Pollution Degree 2 (anticipated transient overvoltage 6000 V) maximum rated voltage to earth CAT III 600 V. Voltage measurement section: Measurement Category CAT III 300 V, CAT II the original battery with a new battery as soon as it is depleted. Indicates AC (Alternating Current). 600 V, Pollution Degree 2 (anticipated transient overvoltage 4000 V) CR2032 lithium batteries (Panasonic or MAXELL) can be purchased at 1. Set the function switch to A. electronics and appliance stores where specialized batteries are sold. Indicates both DC (Direct Current) and AC (Alternating Current). UL61010B 2. CAN/CSA-C22.2No. 1010 2. Clamp the tester on the conductor, so Indicates a grounding terminal. EMC: EN61326 that the conductor passes through the Indicates that the instrument may be connected to or disconnected from center of the clamp core. Clamp the Using the 9209 TEST LEADS HOLDER (Option) a live circuit Functions and Display tester on one lead only. OK No 1. Remove the battery cover, and in its place fit the test lead holder (option). Fasten the The following symbols in this manual indicate the relative importance of cautions and Auto Power Save Function screws securely. warnings. 1. 2. Insert the test lead into the test lead holder. This function automatically switches to the power save state when 30 minutes have Indicates that incorrect operation presents an extreme hazard that elapsed since the last operation. 1. DANGER could result in serious injury or death to the user. The auto power save function is activated automatically when the power is turned on. Voltage Measurement Indicates that incorrect operation presents a significant hazard that To restore from the auto power save state, turn the function switch to the OFF WARNING could result in serious injury or death to the user. 2. position once. DANGER Indicates that incorrect operation presents a possibility of injury to NOTE: The auto power save function cannot be canceled. The maximum input voltage is 600 V AC/DC. Attempting to measure voltage in CAUTION the user or damage to the instrument. Auto-range Function excess of the maximum input could destroy the instrument and result in personal Indicates advisory items related to performance or correct When measuring an AC current ( A), AC voltage ( V), DC voltage ( V), or resistance injury or death. NOTE operation of the instrument. (Ω), the measurement range is automatically set to the most appropriate range. To avoid electrical shock, be careful to avoid shorting live lines with the test leads. Manual Range Function In voltage measurement mode, the maximum rated voltage between input terminals Notes on Operation Power on the tester while holding down a key to select a manual range for measuring and ground is CAT III 300 V, CAT II 600 V. Attempting to measure voltages AC current ( A) , AC voltage ( V) , DC voltage ( V) or resistance (Ω). Note that this exceeding 600 V with respect to ground could damage the instrument and result in Follow these precautions to ensure safe operation and to obtain the full benefits of the various functions. function is not available for continuity testing. Press the Ω SAMP. F/S key to step personal injury. WARNING to the next range. HEAD OFFICE Powering on with the HOLD key held down: manual ranging, with FAST display update Check that the test lead plug is firmly connected to the tester before beginning 81 Koizumi, Ueda, Nagano 386-1192, Japan During current measurement, to avoid an electric shock accident, do not connect the Powering on with the Ω SAMP. F/S key held down: manual ranging, with SLOW measurement. 2. TEL +81-268-28-0562 / FAX +81-268-28-0568 test leads to the instrument. display update Measuring AC Voltage ( V) Outlet E-mail: [email protected] To avoid electric shock, do not allow the instrument to get wet, and do not use it Overflow indication Plug the test leads into the connector. when your hands are wet. When the input exceeds the measurement range, "OF" or "-OF" is displayed. 1. Set the function switch to V. HIOKI USA CORPORATION Do not attempt to adjust or repair the instrument with the case open and with 3. 6 Corporate Drive, Cranbury, NJ 08512, USA 2. Connect the test leads to the object to be voltage being input. Such adjustments or repairs should only be made by a measured. When measuring AC voltage, TEL +1-609-409-9109 / FAX +1-609-409-9108 technician who fully understands the dangers involved. the polarity of the leads can be ignored. 1. Test leads To avoid electric shock when measuring live lines, wear appropriate protective gear, 3. Read the display. URL:http://www.hioki.co.jp such as insulated rubber gloves, boots and a safety helmet.