Pressure Sensor M5091 PDF
Pressure Sensor M5091 PDF
FEATURES
• FM, CSA and ATEX Intrinsically Safe
Models available
• WECO Union pressure fitting
• Shock and vibration resistant
• Eight gage sensor design
• Pressure up to 20,000 PSI
TYPICAL APPLICATIONS
• Oil well servicing
- Cementing
- Fracturing
- Acidizing
S P E C I F I C AT I O N S
PERFORMANCE MECHANICAL
Full Scale Pressure Range (FSPR) . . . . 0-5K, 10K, 15K, 20K PSIG Pressure Connection . . . . . . . . Male WECO Wing Union #1502
Non-Linearity (Best Fit Straight Line) . . . < 0.25% FS Pressure Cavity Volume . . . . . 0.4 cubic inches
Hysteresis & Repeatability . . . . . . . . . . . < ±0.10% FSO Proof Pressure . . . . . . . . . . . . 1.67 times the FSPR or 22,500 PSI (1550 Bar),
Full Scale Output (FSO) . . . . . . . . . . . . . whichever is less
509 . . . . . . . . . . . . . . . . . . . . . . . . 16 mA ±1% Burst Pressure . . . . . . . . . . . . . > 3 times the FSPR, limited by union fitting: 1502
709 . . . . . . . . . . . . . . . . . . . . . . . . 5 VDC ±1% WECO - 22,500 PSI (1530 Bar)
809 . . . . . . . . . . . . . . . . . . . . . . . . 30 mVC ±1% at 10 V excitation Shock Limitation . . . . . . . . . . . 100 G's
Zero Balance Weight . . . . . . . . . . . . . . . . . . 5.5 lbs. nominal
509 . . . . . . . . . . . . . . . . . . . . . . . . 4 mA ±1% FSO Enclosure Materials . . . . . . . . 304 stainless steel
709 . . . . . . . . . . . . . . . . . . . . . . . . 0 VDC ± 1% FSO Wetted Materials . . . . . . . . . . . Inconel X-750
809 . . . . . . . . . . . . . . . . . . . . . . . . 0 mV ± 1% FSO Identification . . . . . . . . . . . . . . Laser etched onto body
Long Term Stability . . . . . . . . . . . . . . . . < ±0.5% FSO per 6 months Enclosure Classification . . . . . . NEMA 4X
Response Time . . . . . . . . . . . . . . . . . . . < 2.5 mSec to reach 90% of FSO
Temperature Effect on Zero . . . . . . . . . . < ±1% FSO per 100° F CERTIFICATIONS Optionally Available
Temperature Effect on Span . . . . . . . . . < ±1% FSO per 100° F FM . . . . . . . . . . . . . . Intrinsically Safe: Class I, Div I, Groups
Compensated Temperature Range . . . . . 40° F to +140° F A-D, Class I, Zone 0. AEx ia IIC T5 at Ta=40°C.
Operating Temperature Limits . . . . . . . . -40° F to +250° F Hazardous Locations installed per CD0641
Storage Temperature Limits . . . . . . . . . . -67° F to +302° F CSA . . . . . . . . . . . . . CSA 03 1437390X
Class I, Div 1, Groups A-D
ELECTRICAL Ex ia IIC T5 at Ta=40°C per CD0640
Supply Voltage ATEX . . . . . . . . . . . . II 1 G
509 . . . . . . . . . . . . . . . . . . . . . . . . 9 to 30 VDC (12 to 28 VDC w/ approval) EEx ia IIC T4/ T5 at Ta=80°C/40°C
709 . . . . . . . . . . . . . . . . . . . . . . . . 9 to 30 VDC (12 to 28 VDC w/ approval) DNV-2003-OSL- ATEX-0188 0575
809 . . . . . . . . . . . . . . . . . . . . . . . . 10 VDC nominal (15 VDC max) (509 & 709 only)
Power Supply Regulation CE . . . . . . . . . . . . . . EMC Directive 89/336/EEC and
(Calibrated @ 12VDC) Low Voltage Directive 72/23/EEC
509 . . . . . . . . . . . . . . . . . . . . . . . . < ±0.01% FSO per Volt EN 61010-1 (1993)/ Safety Requirements
709 . . . . . . . . . . . . . . . . . . . . . . . . < ±0.01% FSO per Volt EN 61326-(2001) - EMC Requirements
809 . . . . . . . . . . . . . . . . . . . . . . . . Output varies with Input (cal. at 10.00 VDC) PED Directive 97/23/EC
Output Signal OPTIONS
509 . . . . . . . . . . . . . . . . . . . . . . . . 4-20 mA at 70° Codes
709 . . . . . . . . . . . . . . . . . . . . . . . . 0-5 Volts at 70° Customer modification
809 . . . . . . . . . . . . . . . . . . . . . . . . 3 mV/Volt at 70° DH .............. Special range
Current Draw EA .............. Special calibration
709 . . . . . . . . . . . . . . . . . . . . . . . . 7.5 mA NK .............. ATEX IS label ( 509 & 709 only)
809 . . . . . . . . . . . . . . . . . . . . . . . . 1 mA @ 10VDC nominal NJ .............. CE label
Load Impedance NX .............. CSA IS label (509 $ 709 only)
509 . . . . . . . . . . . . . . . . . . . . . . . . 750K Ohms maximum at 24 VDC TF .............. FM IS label (509 &709 only)
709 . . . . . . . . . . . . . . . . . . . . . . . . 410K Ohms minimum for <1% FSO attenuation TP .............. Low cavity volume sensor design
809 . . . . . . . . . . . . . . . . . . . . . . . . 350K Ohms minimum for <1% FSO attenuation ZQ .............. GC379-2-145-2P (Glenair) electrical connector.
Range Calibration Signal . . . . . . . . . . . . 100% of FSPR ZT .............. REC-M-10TP-N-04-16 (Jupiter) connector
Calibration Power ACCESSORIES Carrying handle Adapter fastener kit
509 . . . . . . . . . . . . . . . . . . . . . . . . 9 to 30 VDC at 15 mA nominal Connector fastener kit Retaining ring tool
709 . . . . . . . . . . . . . . . . . . . . . . . . Short pins E & F Buna-N O-Ring seal
809 . . . . . . . . . . . . . . . . . . . . . . . . Short pins E & F
Calibration Signal Accuracy . . . . . . . . . . < ±0.2% FSO. The exact signal to pressure STANDARD PIN CONNECTIONS
correlation is provided with each unit. Some models are provided with customer specified wiring.
Circuit Protection . . . . . . . . . . . . . . . . . . Varistor protected across the input leads for Consult Viatran for exact wiring connections.
surges to 1000V @ 50 microseconds. Reverse
509 709 809
polarity protected.
Bridge Resistance . . . . . . . . . . . . . . . . . 10K Ohms nominal PIN A +Power/Signal +Power +Power
Insulation Resistance . . . . . . . . . . . . . . > 100 MegOhms to case ground PIN B -Power/Signal -Power -Power
Electrical Connection . . . . . . . . . . . . . . . Mates with Bendix P/N PT06E-10-6S or PIN C No Connection +Signal +Signal
equivalent. See table for pin connections. PIN D No Connection -Signal -Signal
PIN E +Calibration -Calibration -Calibration
PIN F -Calibration +Calibration +Calibration