Concrete Pressure Analysis: Ref. 1. Concrete Properties:: Wall & Column Formwork Analysis

The document analyzes the concrete pressure and formwork for a wall or column. It details the concrete properties, calculates the pressure load, and analyzes the required formwork height, width, and tie rod reactions. The maximum calculated pressure is 87.5 kPa and the design pressure used is 61.55 kPa. The required tie rod diameter is determined to be 17 mm.

Uploaded by

Lynzer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views1 page

Concrete Pressure Analysis: Ref. 1. Concrete Properties:: Wall & Column Formwork Analysis

The document analyzes the concrete pressure and formwork for a wall or column. It details the concrete properties, calculates the pressure load, and analyzes the required formwork height, width, and tie rod reactions. The maximum calculated pressure is 87.5 kPa and the design pressure used is 61.55 kPa. The required tie rod diameter is determined to be 17 mm.

Uploaded by

Lynzer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Project: Made By: CGB

Location: Checked By:


Client: Date: 7/13/2014
Job Title WALL & COLUMN FORMWORK ANALYSIS Job.No/ Rev.

CONCRETE PRESSURE ANALYSIS: REF.

1. CONCRETE PROPERTIES: ACI 347-04

c = 25.00 kN/m³ 2548 kg/m³ Unit weight of Concrete


Type = 2.00 unitless Cement type or blend
1 - Types I, II, and II without retarders.
2 - Types I, II, and II with retarders. Unit Weight Coefficient:
3 - Other types or blends containing less than 70% slag
or 40 % fly ash without retarders
4 - Other types or blends containing less than 70% slag
or 40 % fly ash with retarder.
5 - Blends containing more than 70% slag or 40% fly ash.
Cc = 1.20 unitless Chemistry Coefficient Table 2.2
Cw = 1.098 unitless Coefficient due to Unit Weight Table 2.1

2. PRESSURE LOAD ANALYSIS:

EL = 2.00 unitless 1 - for Column, 2 - for Wall For Column: Eqtn. 2.2
Ht = 3.500 m Height of the Concrete
R= 3.00 m/hr Rate of Pouring
T= 30.0 ºC Temperature of Concrete
For Wall: Eqtn. 2.3
Pmin = 32.95 kPa 30Cw , Minimum pressure
Pmax = 87.50 kPa  gh , Maximum pressure
Pcal = 61.55 kPa CwCc [7.2 + 1156/ (T+17.8) + 785R/ (T+17.8)]
Calculated pressure

Pd = 61.55
61 55 kPa Design pressure (for analysis)
Hz = 2.46 m Height of Hydrostatic Zone Eqtn. 2.4

3. FORMWORK ANALYSIS:

P_Ht = 4.308 m Formwork Height SOL/MTH


P_Wi = 2.40 m Formwork Width Catalogue
T_Wi = 1.20 m Triburaty Width consider in analysis
5

- Tie Rod Location and Reaction


4.5
T-1 = 82.63 kN Tie Rod Reaction 1 4.31
T-2 = 69.18 kN Tie Rod Reaction 2 4
T-3 = 15.78 kN Tie Rod Reaction 3
T-4 = 0.01 kN Tie Rod Reaction 4 3.5
T-5 = 0.00 kN Tie Rod Reaction 5
T-6 = 0.00 kN Tie Rod Reaction 6 3
T-7 = 0.00 kN Tie Rod Reaction 7
T-8 = 0.00 kN Tie Rod Reaction 8
2.5
T-9 = 0.00 kN Tie Rod Reaction 9

2
- REMARKS:

THEREFORE, USE TIE ROD ø17 mm 1.5

0.5

0.000
0 20 40 60 80 100

SO BANCHE PRESSURE DIAGRAM

D:\Cris Files\old drive d\Calculation Files\Excel Sheet File\SO Panel Template By: CGB