Circuit Breakera319.2

This document provides a list of circuit breakers and their panel designations and locations for an aircraft. It includes circuit breakers for systems like air conditioning, auto flight, communication, electrical power, and various galley equipment. There are over 200 circuit breakers listed, organized by system and spread across multiple panels in different areas of the aircraft.

Uploaded by

Bruno Marinho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
415 views62 pages

Circuit Breakera319.2

This document provides a list of circuit breakers and their panel designations and locations for an aircraft. It includes circuit breakers for systems like air conditioning, auto flight, communication, electrical power, and various galley equipment. There are over 200 circuit breakers listed, organized by system and spread across multiple panels in different areas of the aircraft.

Uploaded by

Bruno Marinho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 62

BSBMW PISTA

CIRCUIT BREAKER A319/320


REF AMM 24-50-00-001
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
AIR CONDITIONING SYSTEM 122VU AIR COND/FLOW/MIXER/FLAP V22
122VU AIR COND/FLOW/CTL & IND 2 V21
49VU AIR COND/RAM/AIR/INLET D10
49VU AIR COND/CAB/PRESS CTL 1 D09 123VU AVNCS VENT/BLOWER FAN AD10
49VU AIR COND/AVNCS VENT/CTL D06 123VU AVNCS VENT/EXTC FAN AE02
49VU AIR COND/FLOW/CTL & IND 1 D07
49VU AIR COND/AVNCS VENT CTL D05 AUTO FLIGHT

122VU AIRCO/LAV/GALL VENT CTL EXTR. FAN CTL U21


122VU AIRCO/LAV/GALL VENT CTL EXTR. FAN SPLY U19 49VU AUTO FLIGHT/FCU 1 B05
122VU AIR COND/ZONE TEMP CTL/28VDC/SYS 2 V20 49VU AUTO FLIGHT/FAC 1/28 VDC B04
122VU AIR COND/ZONE TEMP CTL/28VDC/SYS 1 V19 49VU AUTO FLIGHT/FAC 1/26 VAC B03
122VU AIR COND/ZONE TEMP CTL/115VAC/SYS 2 V18 49VU AUTO FLIGHT/FMGC/1 B02
122VU AIR COND/ZONE TEMP CTL/115VAC/SYS 1 V17 49VU AUTO FLIGHT/MCDU/1 B01
122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC W22
122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC W21 121VU AUTO FLIGHT/FCU 2 M21
122VU AIR COND/RECIRC FAN/R/CTL W20 121VU AUTO FLIGHT/RUDDER/TRIM/IND M20
122VU AIR COND/RECIRC FAN/R/SPLY W18 121VU AUTO FLIGHT/FAC 2/ 28 VDC M19
122VU AIR COND/PACK TEMP/CTL SYS 1/115VAC X22 121VU AUTO FLIGHT/FAC 2/ 26 VAC M18
122VU AIR COND/PACK TEMP/CTL SYS 1/28VDC X21 121VU AUTO FLIGHT/FMGC 2 M17
122VU AIR COND/RECIRC FAN/L/CTL X20 121VU AUTO FLIGHT/MCDU 2 N20
122VU AIR COND/RECIRC FAN/L/SPLY X18 121VU AUTO FLIGHT/RUDDER/ARTF/FEEL N17
122VU AIR COND CABIN PRESS./CTL/MAN Y23 121VU AUTO FLIGHT/STICK//LOCK N16
122VU AIR COND/CABIN PRESS./CTL 2 Y22
122VU AIR COND/PACK TEMP CTL SYS 2/2/28VDC Y21 COMMUNICATION
122VU AIR COND/PACK TEMP CTL SYS 2/2/115VAC Y20
122VU AIR COND/PACK TEMP CTL SYS 2/1/28VDC Y19 49VU COM/CVR/SPLY E14
122VU AIR COND/PACK TEMP CTL SYS 2/1/115VAC Y18 49VU COM/CVR/CTL E13
122VU AIR COND/AVNCS/VENT/MONG Y17 49VU COM/RMP 1 G10
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
49VU COM/VHF 1 G09 121VU COM NAV/CIDS/DEU A NORM/R MID MZA/MZF M12
49VU COM/ÁUDIO/FLT/INTPH G08 121VU COM NAV/CIDS/DEU A NORM/L MID MZA/MZF M11
49VU COM/AUDIO/ACP/F/O G07 121VU COM NAV/CIDS/DEU A NORM/R FWD MZA/MZF M10
49VU COM/AUDIO/ACP/CAPT G06 121VU COM NAV/CIDS/DEU A NORM/L FWD MZA/MZF M09
49VU COM/CIDS/DEU A ESS/LINE 2 G05 121VU COM NAV/CIDS/DEU B/NORM MZA/MZF M08
49VU COM/CIDS/DEU A ESS/LINE 1 G04 121VU COM NAV/CIDS/PROG &/TST PNL MZA/MZF M07
49VU COM/CIDS DEU B/ESS G03 121VU COM NAV/CIDS/DIR NORM 2 MZA/MZF M06
49VU COM/CIDS/DIR 1 AND 2 ESS MZG G02 121VU COM NAV/CIDS/DIR NORM 1 MZA/MZF M05
49VU COM DIR ESS 2 PT-MZA/MZF G02 121VU COM/CIDS/FWD ATTND/PNL MZA/MZF Q14
49VU COM DIR ESS 1 PT-MZA/MZF G01 121VU SATCOM MZG/MZJ K01
49VU COM HF 1 HA14 121VU COM NAV/CIDS/FWD ATTND/PNL MZG/MZJ Q14
121VU COM NAV/RMP 3 L03
121VU COM NAV/VHF 2 L02 121VU COM NAV/VHF 3 L05
121VU COM NAV/CIDS/FWD ATTND/PNL MZG/MZH M14
121VU COM NAV/CIDS/DEU A NORM/R AFT MZG/MZJ M13 ELETRICAL POWER
121VU COM NAV/CIDS/DEU A NORM/L AFT MZG/MZJ M12
121VU COM NAV/CIDS/DEU A NORM/R MID MZG/MZJ M11 49VU ELEC/LT/CTL H10
121VU COM NAV/CIDS/DEU A NORM/L MID MZG/MZJ M10 49VU ELEC/AC BUS/8XP/MONG H11
121VU COM NAV/CIDS/DEU A NORM/R FWD MZG/MZJ M09
121VU COM NAV/CIDS/DEU A NORM/L FWD MZG/MZJ M08 105VU ELEC/CSM/G/EV AUTO/SPLY C01
121VU COM NAV/CIDS/DEU B NORM MZG/MZJ M07 105VU ELEC/HOT BUS/702PP SPLY D02
121VU COM NAV/CIDS/PROG AND TEST PNL MZG/MZJ M06 105VU ELEC/HOT BUS/701PP SPLY D01
121VU COM NAV/CIDS/DIR 1 AND 2/NORM MZG/MZJ M05 105VU ELEC/HOT BUS/702PP SPLY E02
121VU COM NAV/SELCAL M04 105VU ELEC/HOT BUS/701PP SPLY E01
121VU COM NAV/ACP/THIRD/OCCPNT M02 105VU ELEC/ STATIC INV/CNTOR/CTL G02
121VU EIS/HORN/SPLY P09 105VU ELEC/STAT INV/BUS 901XP SPLY H02
121VU COM NAV/CIDS/DEU A NORM/R AFT MZA/MZF M14 105VU ELEC/BAT BUS/REF/BCL 1 AS01
121VU COM NAV/CIDS/DEU A NORM/L AFT MZA/MZF M13 105VU ELEC/BAT BUS/REF/BCL 2 AS01
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
105VU ELEC/BAT REF/BCL 1 AS01 122VU ELEC/REFLNG/ON/BAT U28
105VU ELEC/BAT REF/BCL 2 AS01 122VU ELEC/CNTOR/DC BUS/TIE 1/FAULT U24
122VU ELEC/AC PWR/SVCE/CTL V29
106VU AC ESS BUS/STBY/CNTOR/CTL B08 122VU ELEC/BUS/2XP/CTL V27
106VU AC ESS BUS/EMER/CNTOR/CTL B07 122VU ELEC/AC/BUS 1/CTL V25
106VU 26VAC/ESS BUS/SPLY B06 122VU ELEC/TR 2/FAULT/DC BUS TIE/CONFIG W30
106VU CSM/G/EV/MAN/SPLY B04 122VU ELEC/TR 1/FAULT/DC BUS TIE/CONFIG W29
106VU AC ESS/BUS NORM/CNTOR/CTL B03 122VU ELEC/CNTOR/ESS/DC BUS/TIE W26
106VU AC ESS/BUS/EMER/CNTOR/SPLY C08 122VU ELEC/CNTOR/DC BUS/TIE W25
106VU EMER/SHED/CNTOR/SPLY C07 122VU ELEC/EXT PWR/LT CLT/AVAIL X31
106VU AC ESS BUS/EMER/STBY/CNTOR/SPLY C06 122VU ELEC/EXT PWR/LT CLT/NOT IN/USE X30
106VU AC ESS BUS/MONG/SPLY C05 122VU ELEC/EXT PWR/CTL X29
106VU AC/SHED/ESS BUS/CNTOR/CTL C04 122VU ELEC/EXT PWR/COCKPIT/AVAIL/LT X28
106VU ESS TR/CNTOR/CTL C02 122VU ELEC/TR 2/MONG X26
106VU ESS TR/SPLY AS01 122VU ELEC/TR 1/MONG X25
122VU ELEC/DC/SVCE/BUS X24
122VU ELEC/GALLEY/CNTOR S28 122VU APU GEN/EGIU 2/28VDC Y31
122VU ELEC/REFLNG/NORM S27 122VU GEN 2/EGIU 2/28VDC Y30
122VU ELEC/GEN 2/OFF/BTC 2 SPLY T31 122VU ELEC/APU/GCU Y25
122VU ELEC/GEN 1/OFF/BTC 2 SPLY T30 122VU ELEC/GPCU Y24
122VU ELEC/GEN 2/OFF/BTC 1 SPLY T29 122VU ELEC/EXT PWR/EGIU 1/28VDC Y31
122VU ELEC/GEN 1/OFF/BTC 1 SPLY T28 122VU ELEC/GEN 1/EGIU 1/28VDC Z30
122VU ELEC/GCU 2 T27 122VU ELEC/EMER AUTO 2 Z26
122VU ELEC/GCU 1 T26 122VU ELEC/EMER GEN AUTO 1 Z25
122VU ELEC/IDG 2/DISC T25 122VU ELEC/DC BUS/TIE 2/APU START W31
122VU ELEC/IDG 1/DISC T24 122VU ELEC/GALY & CAB CTL S26
122VU ELEC/DC SVCE/BUS/ON TR 2 U30 122VU ELEC/GALY & CAB/FAULT/LT CTL S25
122VU ELEC/RFL/SPLY/LOGIC U29 122VU ELEC/GALY & CAB/GND/FLT/LOGIC S24
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
122VU ELEC/DC SHED BUS/CNTR U26 123VU AFT GALLEY/FEEDER B AD09
122VU ELEC/AC SHED BUS/CNTR U25 123VU MAIN FWD GALLEY/FEEDER C AE10
123VU SHED BUS/218XP/220XP SPLY AC02
123VU GALLEY PWR –E- AE10
123VU APU GEN/EGIU 2/115VAC AA08 124VU SVCE/601PP/602PP/SPLY BB01
123VU EXT PWR/EGIU 1/115VAC AA07 124VU TR 2/CNTOR/SPLY BC01
123VU SVCE/BUS 2/214XP SPLY AA05 124VU DC SVCE/602PP/SPLY BD01
123VU BUS 1/131XP-A/SPLY AB12 124VU 206PP/208PP/SPLY BE01
123VU BUS 1/103XP/SPLY AB11 124VU 204PP/SPLY BF01
123VU TR 1/SPLY AB10 124VU 202PP/SPLY BG01
123VU TR 2/SVCE/BUS 2/SPLY AB08 124VU SHED BUS 210PP/212PP/SPLY BA01
123VU GND/PWR/PROT AB07
123VU SVCE/BUS 2/212XP SPLY AB05 125VU BAT BUS/301PP/SPLY CC01
123VU TR 2/214XP/SPLY AB04 125VU 101PP/SPLY CD01
123VU BUS 2/204XP/SPLY AB02 125VU 103PP/SPLY CE01
123VU BUS 2/213XP-A/SPLY AB01 125VU TR 1/CNTOR/SPLY CF01
123VU AC ESS/BUS ON/BUS 1 AC12
123VU AC ESS/BUS ON/BUS 2 AC01 EQUIPMENT/FURNISHINGS SYSTEM
123VU BUS 1/101XP/SPLY AD11
123VU GALLEY D AD04 122VU COCKPIT SEATS/SEAT CTL/F/O U14
123VU BUS 2/212XP/SPLY AD03 122VU COCKPIT SEATS/SEAT CTL/CPT U11
123VU BUS 2/202XP/SPLY AD02 2001VU VACUUM CLEANER SOCKET CARGO Z0261 F01
123VU GEN 1/EGIU 1/115VAC AF12
123VU BUS 1/110XP/SPLY AF11 FIRE PROTECTION SYSTEM
123VU BUS 2/210XP/SPLY AF02
123VU GEN 2/EGIU 2/115VAC AF01 49VU ENGINE 2/FIRE DET./LOOP B A07
123VU MAIN FWD GALLEY FEEDER F AC10 49VU ENGINE 1/FIRE DET./LOOP A A06
123VU MAIN AFT GALLLEY FEEDER A AF04 49VU AIR COND/SDCU/CHAN 1 C06
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
121VU APU/FIRE AND OVHT/DET/LOOP B L44 105VU FLT CTL/ELAC 1/STBY SPLY A01
121VU APU/FIRE AND OVHT/DET/LOOP A L43 105VU FLT CTL/SEC 1/STBY SPLY B01
121VU APU/AUTO/EXTIG/GND/TEST L40
121VU APU/FIRE/EXTIG/SQUIB B L39 121VU FLIGHT CONTROLS/WTB/FLP/SYS 2 P20
121VU APU/FIRE/EXTIG/SQUIB A L38 121VU FLIGHT CONTROLS/WTB/SLT/SYS 2 P19
121VU APU/FIRE/LP VALVE/NORM M42 121VU FLIGHT CONTROLS/SLT/PS/IND 2 P16
121VU APU/FIRE/LP VALVE/STBY M41 121VU FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS 2 Q21
121VU ENGIN/ENG 1 AND 2 FIRE EXTIG/BTL 1/SQUIB B Q44 121VU FLIGHT CONTROLS/FCDC 2/SPLY Q20
121VU ENGIN/ENG 1 AND 2 FIRE EXTIG/BTL 1/SQUIB A Q43 121VU FLIGHT CONTROLS/SEC 3/SPLY Q19
121VU ENGIN/ENG 1 AND 2 FIRE EXTIG/BTL 2/SQUIB B Q42 121VU FLIGHT CONTROLS/SEC 2/SPLY Q18
121VU ENGIN/ENG 1 AND 2 FIRE EXTIG/BTL 2/SQUIB A Q41 121VU FLIGHT CONTROLS/THS ACTR/MOT 3 Q17
121VU ENGINE/ENG 2/FIRE DET/LOOP A Q39 121VU FLIGHT CONTROLS/THS ACTR/MOT 1 Q16
121VU ENGINE/ENG 1/FIRE DET/LOOP B Q38 121VU FLIGHT CONTROLS/SLT/CTL/SYS 2 R21
121VU FLIGHT CONTROLS/ELAC 2/NORM/SPLY R20
122VU AIR COND/SDCU/CHAN 2 T18
122VU AIR COND/CARGO/FIRE/EXTIG T19 122VU FLIGHT CONTROLS/WTB/FLP/SYS 1 S07
122VU FLIGHT CONTROLS/WTB/SLT/SYS 1 S06
FLIGHT CONTROLS SYTEM
FUEL SYSTEM
49VU FLIGHT CONTROLS/SLT FLP/POS IND 1 B12 49VU FUEL/SMOKE/CONFIG/PUMP CTL A14
49VU FLIGHT CONTROLS/ELAC 1/NORM/SPLY B11 49VU FUEL FQI CHAN 1 A13
49VU FLIGHT CONTROLS/FCDC 1/SPLY B10 49VU FUEL/X FEED/VALVE/MOT 1 A12
49VU FLIGHT CONTROLS/THS/ACTR/MOT 2 B09 49VU FUEL/X FR VALVE 1/WING R A11
49VU FLIGHT CONTROLS/SEC 1/NORM/SPLY B08 49VU FUEL/X FR VALVE 1/WING L A10
49VU FLIGHT CONTROLS/FLP/CTL AND MONG/SYS 1 B07 49VU FUEL/LP VALVE/MOT 1/ENG 2 A09
49VU FLIGHT CONTROLS/SLT/CTL AND MONG/SYS 1 B06 49VU FUEL/LP VALVE/MOT 1/ENG 2 A08
49VU APU/FUEL/BLOW OFF/PUMP B14
105VU FLIGHT CONTROLS/ELAC 2/STBY SPLY A02
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
121VU APU/FUEL/BLOW OFF/CTL K39 123VU L WING TK/PUMP 1/STBY SPLY AD12
121VU FUEL FQI CHANNEL 1 AND 2 L26 123VU R WING TK/PUMP 1/STBY SPLY AE12
121VU FUEL/HI/LVL/SPLY L25
121VU FUEL/RFL/DFL/SPLY L24 HIDRAULIC POWER SYSTEM
121VU FUEL/RFL/DFL/XFR/DEFUEL/VALVE L23
121VU APU/FUEL/LP VALVE/CTL M40 49VU HYD/FIRE VALVE/Y/ENG 2 C14
121VU APU/FUEL/LP VALVE/SPLY M39 49VU HYD/FIRE VALVE/G/ENG 1 C13
121VU APU/FUEL/PUMP/CTL M38 49VU HYD/RAT/CTL D14
121VU FUEL FQI CHANN 2 M27 49VU HYD/HYD POWER/B WARN & CTL C12
121VU FUEL/LP VALVE/MOT 2/ENG 2 M26 49VU HYD/HYD/PRESS XMTR C11
121VU FUEL/LP VALVE/MOT 2/ENG 1 M25
121VU FUEL/X FEED/VALVE/MOT 2 M24 121VU HYDRAULIC/SOL VALVES/G/Y/B/LEAK TEST N35
121VU FUEL/X FR VALVE 2/WING R M23 121VU HYDRAULIC/SOL VALVES/G/Y/PTU N34
121VU FUEL/XFR VALVE 2/WING L M22 121VU HYDRAULIC/LOW/LVL/IND N32
121VU FUEL/L WING TK/PUMP 2 SPLY N26 121VU HYDRAULIC/HYD POWER Y N30
121VU FUEL/L WING TK/PUMP 1 SPLY N23 121VU HYDRAULIC/HYD/QTY IND P35
121VU FUEL/R WING TK/PUMP 2 SPLY Q26 121VU HYDRAULIC/RAT/SPLY/EXTN/SOL 1 P33
121VU FUEL/R WING TK/PUMP 1 SPLY Q23 121VU HYDRAULIC/Y HYD/PUMP ENG 2/MONG Q37
121VU FUEL/PUMPS 2 R CTL AND L IND R29 121VU HYDRAULIC/Y HYD/PUMP ENG 2/CTL Q36
121VU FUEL/PUMPS 1 R CTL AND L IND R28 121VU HYDRAULIC/G HYD/PUMP ENG 1/CTL R35
121VU FUEL/PUMPS 2 L CTL AND R IND R24 121VU HYDRAULIC/G HYD/PUMP ENG 1/MONG R34
121VU FUEL/PUMPS 1 L CTL AND R IND R23
121VU FUEL/CTR TK/PUMP 2 SPLY P26 123VU B HYDRAULIC/ELEC PUMP AB09
121VU FUEL/CTR TK/PUMP 1 SPLY P23 123VU Y HIDRAULIC/ELEC/PUMP AB06
121VU FUEL/CTR TK/PUMP/AUTO/CTL R27 123VU Y HIDRAULIC/ELEC/ELEC PUMP NORM AB03
121VU FUEL/CTR TK/PUMPS 1 AND 2 CTL AND IND R26
121VU FUEL/CTR TK/PUMPS 1 AND 2 CTL AND IND R25
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
ICE AND RAIN PROTECTION SYS 122VU ANTI ICE/PROBES/P 2/T 2/ENG 1 Z10
122VU ANTI ICE/PROBES 2/PHC Y12
49VU ANTI ICE/PROBES AOA 1 D04 122VU ANTI ICE/RAIN/RPLNT/F.O –MZC/MZF/MZG/MZJ W11
49VU ANTI ICE/PROBES PHC 1 D03
49VU ANTI ICE/PROBES PITOT 1 D02 123VU ANTI ICE WINDSHIELD L AF10
49VU ANTI ICE/RAIN/RPLNT/CAPT D01 123VU ANTI ICE WINDSHIELD R AF03
49VU ANTI ICE/WING CTL C02 2000VU WATER SYSTEM ICE PROT CTL D08
49VU ANTI ICE/WING/MONG C01 2000VU WATER SYSTEM ICE PROT HTR D07

122VU ANTI ICE/WINDOWS R W14 INDICATING RECORDING SYSTEM


122VU ANTI ICE/WHC 2 W13
122VU ANTI ICE/FIRST OFFICER WIPER W12 49VU EIS/ECAM/CTL/PNL E12
122VU ANTI ICE/ENG 2 W10 49VU EIS/DMC 1/CTL/SPLY E11
122VU ANTI ICE/WINDOWS L X14 49VU EIS/DMC 3/STBY/SPLY E10
122VU ANTI ICE/WHC 1 X13 49VU EIS/DMC 1/SWTG E09
122VU ANTI ICE/ CAPT WIPER X12 49VU EIS/RLY/BOX/CAPT E08
122VU ANTI ICE/ENG 1 X10 49VU EIS/DMC 3/SWTG E07
122VU ANTI ICE/PROBES/PHC 3 Y16 49VU EIS/ECAM DU/UPPER/SWTG E06
122VU ANTI ICE PROBES Y15 49VU EIS/ECAM DU/UPPER/SPLY E05
122VU ANTI ICE PROBES Y14 49VU EIS/PFD CAPT/SWTG E04
122VU ANTIICE PROBES 2/AOA Y13 49VU EIS/PFD CAPT/SPLY E03
122VU ANTI ICE/PROBES AND SENSORS 2/STATIC Y11 49VU CLOCK/NORM/SPLY F11
122VU ANTI ICE/PROBES AND SENSORS 3/PITOT Z16 49VU CAPT/LOUD SPKR F10
122VU ANTI ICE/PROBES 3/AOA Z15 49VU SDAC 1 AND 2/28VDC/ AC ESS BUS F05
122VU ANTI ICE/PROBES Z14 49VU SDAC 1/SPLY F04
122VU ANTI ICE/PROBES AND SENSORS 1/STATIC Z13 49VU SDAC 2/26VAC SYNC/AC ESS BUS F03
122VU ANTI ICE/PROBES AND SENSORS 1/STATIC Z12 49VU SDAC 1/26VAC SYNC/AC ESS BUS F02
122VU ANTI ICE/PROBES/P 2/T 2/ENG 2 Y10 49VU NAV/DME 1 G14
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
49VU EIS/ND CAPT/SWTG E02 121VU EIS/SDAC 2/BUS 2/26VAC SYNC AC Q03
49VU EIS/ND CAPT/SPLY E01 121VU EIS/SDAC 1/BUS 2/26VAC SYNC AC Q02
49VU FWS/FWC 1/SPLY F01 121VU EIS/ECAM DU/LOWER/SPLY R11
121VU EIS/ECAM DU/LOWER/SWTG R10
106VU EMER/GEN/REF B05 121VU EIS/DMC 2/SWTG R08
106VU DC/BUS 1 AND 2/MONG C03 121VU EIS/RLY/BOX/FIRST OFFICER R07
121VU EIS ND/FIRST OFFICER/SWTG R06
121VU CLOCK/STBY/SPLY –PTMZC/MZD N02 121VU EIS PFD/FIRST OFFICER/SWTG R05
121VU PTR/SPLY J21 121VU EIS ND/FIRST OFFICER R04
121VU CFDS/TEST PLUG 2 J20 121VU EIS PFD/FIRST OFFICER R03
121VU CFDS/TEST PLUG 1 J19 121VU CLOCK/STBY/SPLY –PT-MZA/MZF/MZG/MZH N03
121VU CFDS/CFDIU/SPLY J18 121VU DATA LOADER/SPLY J16
121VU CFDS/CFDIU/BACKUP J17 121VU AIDS/DMU AND QAR K15
121VU RCDR/ACCLRM K18
121VU RCDR/FDIU AND QAR K17 LANDING GEAR SYSTEM
121VU RCDR/DFDR K16
121VU COM NAV/DME 2 K06 49VU LANDING GEAR Y BRK/PRESS IND C10
121VU EIS/FIRST OFFICER/LOUD SPKR P08 49VU LANDING GEAR/LGCIU/SYS 1/NORM C09
121VU EIS/SDAC 1 AND 2/DOOR DET PAX P05
121VU EIS/SDAC 1 AND 2/BUS1/28VDC P04 121VU HYDRAULIC/BRK FAN WHEELS 3 & 4 L35
121VU EIS/SDAC 1 AND 2/BUS 2/28VDC P03 121VU HYDRAULIC/BRK FAN WHEELS 1 & 2 L32
121VU EIS/SDAC 1 AND 2/DOOR DET AVCNS P02 121VU HYDRAULIC/BRK FAN CTL M32
121VU EIS/DMC 3/SPLY Q09 121VU HYDRAULIC/BRK TEMP DET UNIT M37
121VU EIS/DMC 2/SPLY Q08 121VU HYD BRAKING AND STEERING SYS2/ SPLY M36
121VU EIS/FWC 2/SPLY Q07 121VU HYD BRAKING AND STEERING SYS 2/CTL M35
121VU EIS/SDAC 2/SPLY Q06 121VU HYD BRAKING AND STEERING SYS 1/CTL M34
121VU EIS/SDAC 2/BUS 1/26VAC SYNC AC Q05 121VU HYD BRAKING AND STEERING SYS 1 IND/SPLY M33
121VU EIS/SDAC 1/BUS 1/26VAC SYNC AC Q04 121VU HYDRAULIC/PARK BRK/CTL/STBY N37
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
121VU HYDRAULIC/PARK BRK/CTL/NORM N36 122VU LIGHTING/EXT LT/RWY TURN OFF L W06
121VU HYDRAULIC/LGCIU SYS 2 O35 122VU LIGHTING/EXT LT/RWY TURN OFF R W05
121VU HYDRAULIC/LGCIU SYS 1/GRND SPLY Q34 122VU LIGHTING/EXT LT/WING AND ENG SCAN R W03
122VU LIGHTING/EXT LT/WING AND ENG SCAN L W02
LIGHTS SYSTEM 122VU LIGHTING/WHL WELL/LTG DOME X08
122VU LIGHTING/WHL WELL/LTG OUT X07
49VU LIGHTING EMER LT/CKPT DOME H08 122VU LIGHTING/TST BOARD SPLY X06
49VU LIGHTING EMER LT/CABIN H07 122VU LIGHTING/ANN LT SPLY/XFMR BUS 2 X05
49VU LIGHTING EMER LT/CABIN –PTMZG/MZH H06 122VU LIGHTING/ANN LT SPLY/XFMR BUS 1 X04
49VU LIGHTING EMER LT/CABIN H05 122VU LIGHTING/ANN LT SPLY/XFMR/STAT INV X03
49VU LIGHTING/XFMR/115V.5V/ESS BUS H03 122VU LIGHTING/CKPT DOME Y06
49VU LIGHTING/ICE AND STBY COMP LIGHT H04 122VU LIGHTING/INSTL LT/GLARE SHLD Y05
122VU LIGHTING/INSTL LT/MAIN INST/PNL AND PED Y04
122VU LIGHTING/EXT LT/NAV 1 AND LOGO LIGHT T03 122VU LIGHTING/INSTL LT OVHD PNL Y03
122VU LIGHTING/EXT LT/NAV 2 AND LOGO LIGHT T02 122VU LIGHTING/AVNCS COMPT/OUT 115VAC Z09
122VU LIGHTING LANDING LT R/CTL T07 122VU LIGHTING/AVNCS COMPT/OUT 28 VDC Z08
122VU LIGHTING LANDING LT R/SPLY T06 122VU LIGHTING/AVNCS COMPT DOME Z07
122VU LIGHTING LANDING LT L/CTL T05 122VU LIGHTING/FLOOD FIRST OFFICER SIDE Z06
122VU LIGHTING LANDING LT L/SPLY T04 122VU LIGHTING/FLOOD CAPT SIDE Z05
122VU LIGHTING EXT LT BEACON UPPER U06 122VU LIGHTING/FLOOD CTR INST PNL Z04
122VU LIGHTING EXT LT BEACON LOWER U03 2000VU AIR CONDTN COMPT OUTLET B08
122VU LIGHTING/CABIN/EMER LT V07 2000VU CARGO COMPT LIGHT-LDG AERA B06
122VU LIGHTING/WING STROBE V05 2000VU CARGO COMPT LIGHT-AFT B05
122VU LIGHTING/LOGO LEFT V03 2000VU CARGO COMPT LIGHT-FWD B04
122VU LIGHTING/LOGO RIGH V02 2000VU PASSENGER READING LIGHT G07
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/CTL W09 2000VU PASSENGER READING LIGHT G06
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TAXI W08 2000VU PASSENGER READING LIGHT G05
122VU LIGHTING/EXT LT/TAXI AND TAKE OFF/TO W07 2000VU PASSENGER READING LIGHT G04
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
2000VU PASSENGER READING LIGHT G03 121VU ADIRS/ADIRU 2 PWR/SHED –PT-MZI/MZJ N10
2000VU PASSENGER READING LIGHT G02 121VU ADIRS/ADIRU 3 PWR/SWTG –PT-MZI/MZJ N09
2000VU CABIN LIGHT POWER-CEILING AFT H08 121VU ADIRS/ADIRU 2/26VAC AND AOA –PT-MZI/MZJ N08
2000VU CABIN LIGHT POWER-CEILING AFT HO7 121VU ADIRS/ADIRU 3/26VAC AND AOA –PT-MZI/MZJ N07
2000VU CABIN LIGHT POWER-CEILING FWD H06 121VU AIDRS/ADIRU 2/115VAC –PT-MZI/MZJ N06
2000VU CABIN LIGHT POWER-CEILING FWD H05 121VU ADIRS/ADIRU 3/115VAC –PT-MZI/MZJ N05
2000VU CABIN LIGHT POWER-WINDOW AFT H04 121VU ADIRS/ADIRU 2/28VDC –PTMZI/MZJ N04
2000VU CABIN LIGHT POWER-WINDOW AFT H03 121VU ADIRS/ADIRU 3/28VDC –PT-MZI/MZJ N03
2000VU CABIN LIGHT POWER-WINDOW FWD H02 121VI COM NAV/RADAR 1 K13
2000VU CABIN LIGHT POWER-WINDOW FWD H01 121VU COM NAV/RAD ALTIMETER 2 K12
2000VU LIGHT-ATTND WORK J05 121VU COM NAV/RAD ALTIMETER 1 K11
2000VU LIGHT-CABIN ENTRY J04 121VU COM NAV/ILS 2 –PTMZA/MZB K09
121VU COM NAV/VOR 2 K08
NAVIGATION SYSTEM 121VU COM NAV/ATC 2 K07
121VU EIS/GPWS/115VAC P07
49VU NAV STBY ALTIMETER F14 121VU EIS/GPWS/28VDC P06
49VU NAV VOR DME RMI F13 121VU COM NAV/RADAR 2 –PT-MZF K14
49VU NAV STBY HORIZONT F12 121VU COM NAV/ADF 2 K02
49VU NAV PROBES ADIRU 3 PWR SWTG F09 121VU ADIRS/ADIRU 2/PWR/SHED –PT-MZA/ZF/ZG/ZH N11
49VU NAV PROBES ADIRU 1 AND AOA 1/26VAC F07 121VU ADIRS/ADIRU 3/PWR/SWTG –PT-MZA/ZF/ZG/ZH N10
49VU NAV PROBES ADIRU 1/115VAC F06 121VU ADIRS/ADIRU 2/26VAC AND AOA-MZA/ZF/ZG/ZH N09
49VU NAV VOR 1 G13 121VU ADIRS/ADIRU 3/26VAC AND AOA-MZA/ZF/ZG/ZH N08
49VU NAV ILS 1 –PTMZA/MZB G12 121VU ADIRS/ADIRU 2/115VAC –PT-MZA/ZF/ZG/ZH N07
49VU NAV ATC 1 G11 121VU ADIRS/ADIRU 3/115VAC –PT-MZA/ZF/ZG/ZH N06
49VU NAV ADF 1 H14 121VU ADIRS/ADIRU 2/28VDC –PT-MZA/ZF/ZG/ZH N05
49VU NAV MMR 1-PTMZA/MZB G12 121VU ADIRS/ADIRU 3/28VDC –PT-MZA/ZF/ZG/ZH N04
121VU COM NAV/MMR 2 –PTMZB/ZC L07
105VU ADIRS/ADIRU 1/28VDC C02 121VU COM NAV/MMR 2 –PT-MZA/ZF/ZG/ZH K09
CIRCUIT BREAKER A319/320 CIRCUIT BREAKER A319/320
PANEL DESIGNATION LOC PANEL DESIGNATION LOC
OXIGEN SYSTEM DOORS SYSTEM

49VU OXYGEN/PASSENGER/ACTUATION HA08 121VU EIS/SLIDES/ARM AND WARN GND P10


49VU OXYGEN/PASSENGER/ACTUATION HA07
49VU OXYGEN/PASSENGER/ACTUATION HA06 122VU DOORS CARGO T12
49VU OXYGEN/PASSENGER/ACTUATION HA05 122VU DOORS PAX MONG T13
49VU OXYGEN/PASSENGER/CTL AND WARN HA04
49VU OXYGEN/PASSENGER/CTL AND WARN HA03 ENGINE SYSTEM
49VU OXYGEN/PASSENGER/CTL AND WARN HA02
49VU OXYGEN/CREW/OXYGEN/SPLY HA01 49VU ENGINE 2/FADEC A AND EIU 2 A05
49VU ENGINE 1/FADEC A AND EIU 1 A04
PNEUMATIC SYSTEM 49VU ENGINE 1 AND 2 ING SYS A A03
49VU ENGINE 2 HP FUEL SOV A02
49VU AIR BLEED/ENG 1 CTL D12 49VU ENGINE 1 HP FUEL SOV A01
49VU AIR BLEED/ENG 1 MONG D11
49VU AIR BLEED/X FEED VALVE/BAT D13 121VU ENGINE IGN ENG 2 SYS B P42
121VU ENGINE IGN ENG 1 SYS B P41
122VU AIR BLEED/ENG 2 CTL Z23 121VU ENGINE IGN ENG 2 SYS A BAT P40
122VU AIR BLEED/ENG 2 MONG Z22 121VU ENGINE IGN ENG 1 SYS A BAT P39
122VU AIR BLEED/X FEED VALVE NORM Z20 121VU ENGINE ENG 2 FADEC B Q40
121VU ENGINE ENG 1 AND 2 EVMU R44
AIRBORNE AUXILIARY POWER SYS 121VU ENGINE ENG 1 FADEC B AND EIU 1 R41
121VU ENG/ENG 2 OIL PRESS AND REV SNSR CHAN A N42
121VU APU/APU CTL L42 121VU ENG/ENG 2 OIL QTY AND VER SNSR CHAN B N41
121VU APU/ECB SPLY L41 121VU ENG/ENG 1 OIL PRESS AND VER SNSR CHAN A N40
121VU APU/OIL HTR SPLY K41 121VU ENG/ENG 1 OIL QTY AND VER SNSR CHAN B N39
121VU ENGINE 2 VER LOCK N45
121VU ENGINE 1 VER LOCK N44
ABREVIATURAS A319/320 ABREVIATURAS A319/320
A/D ANALOG TO DIGITAL CONVERTER ADS AIR DATA SYSTEM
A/F AUTO FLIGHT ADU ALIGN DISPLAY UNIT
A/G AIR TO GROUND AEVC AVIONICS EQUIPMENT VENTILATION COMPUTER
A/R AUDIO REPRODUCER AFC AUTOMATIC FREQUENCY CONTROL
A/S AUTO STABILIZATION AFCS AUTOMATIC FLIGHT CONTROL SYSTEM
A/SKID ANTI-SKID AFECU AUTOMATIC FIRE EXTINGUISHER CONTROL UNIT
AADC ANALOG AIR DATA COMPUTER AFS AUTOMATIC FLIGHT SYSTEM
AAP ADITIONAL ATTENDENT PANEL AHRS ATTITUDE AND HEADING REFERENCE SYSTEM
ABD AIRBUS DIRECTIVES AIDS AIRCRAFT INTEGRATED DATA SYSTEM
ACARS AIRCRAFT COMM. ADRESS. REPORT SYS ALTU ANNUNCIATOR LIGHT TEST UNIT
ACC ACTIVE CLEARENCE CONTROL AMU AUDIP MANAGEMENT UNIT
ACCEL ACCELERATION/ACCELERATE AOA ANGLE OF ATTACK
ACCLRM ACCELEROMETER AOHX AIR/OIL HEAT EXCHANGER
ACMM ABBREVIATED COMPONENT MAINT MANUAL AP/FD AUTO PILOT/FLIGHT DIRECTOR
ACMR AIRCRAFT CONFIGURATION MANAG.RULES APLC AIRCRAFT POWER LINER CONDITIONER
ACMS AIRCRAFT CONDITION MONITORING SYSTEM APPU ASYMETRIC POSITION PICK OFF UNIT
ACOB AUTOMATIC CALL OUT BOX APU AFE APU AUTO. FIRE EXTINGUISHER CONTROL UNIT
ACOC AIR COOLED OIL COOLER ASP AUDIO SELECTOR PANEL
ACP AREA CALL PANEL AT AUTOTHRUST
ACU ANTENNA COUPLER UNIT ATCSS AIR TRAFIC CONTROL DATA LINK SIGNALL SYS
ADAU AUXILIARY DATA ACQUISITION UNIT ATSU AIR TRAFIC SERVICE UNIT
ADC AIR DATA COMPUTER AVRS AUDIO/VIDEO RECORDING SYSTEM
ADG AIR DRIVE GENERATOR BCDS BITE CENTRALIZED SYSTEM
ADI ATTITUDE DIRECTOR INDICATOR BFDAS BASIC FLIGHT DATA ACQUISITION SYSTEM
ADIRS AIR DATA/INERTIAL REFERENCE SYSTEM BIU BITE INTERFACE UNIT
ADIRU AIR DATA/INERTIAL REFERENCE UNIT BMC BLEED MONITORING COMPUTER
ADM AIR DATA MODULE BSCU BRAKE /STEERING SYSTEM UNIT
ADPM AIRCRAFT DEACTIVATION PROCEDURES MANUAL BTR BUS TIE RELAY
ADR AIR DATA REFERENCE BYDU BACK-UP YAW DAMPER UNIT
ABREVIATURAS A319/320 ABREVIATURAS A319/320
CAS COMPUTED AIR SPEED EPSU EMERGENCY POWER SUPLLY UNIT
CBMS/U CIRCUIT BREAKER MONITORING SYSTEM/UNIT EWD ENGINE/WARNING DISPLAY
CCS CABIN COMMUNICATIONS SYSTEM FADEC FULL AUTHORITY DIGITAL ENGINE CONTROL
CECAM CENTRALIZED CABIN MONITORING FAP FORWARD ATTENDENT PANEL
CFDIU CENTRALIZED FAULT DISPLAY INTERFACE UNIT FC FULLY CLOSED
CFDS CENTRALIZED FAULT DISPLAY SYSTEM FCDC FLIGHT CONTROL DATA CONCENTRATOR
CIDS CABIN INTERCOMMUNICATION DATA SYSTEM FCMC FUEL CONTROL AND MONITORING COMPUTER
CLOG CLOGGING FCMS FUEL CONTROL AND MONITORING SYSTEM
CMC CENTRALIZER MAINTENANCE COMPUTER FCPC FLIGHT CONTROL PRIMARY COMPUTER
CMS CABIN MANAGEMENT SYSTEM FCSC FLIGHT CONTROL SECONDARY COMPUTER
CPC CABIN PRESSURE CONTROLLER FCU FLIGHT CONTROL UNIT
CPCS/U CABIN PRESSURE CONTROL SYSTEM/UNIT FCV FLOW CONTROL VALVE
CPMS/U CABIN AND PASSENGER MANAGEMENT SYS/UNIT FDIU FLIGHT DATA INTERFACE UNIT
DADC/S DIGITAL AIR DATA COMPUTER/SYSTEM FDU FIRE DECTECTION UNIT
DCDU DATA CONTROL AND DISPLAY UNIT FG FLIGHT GUIDANCE
DMC DISPLAY MANAGEMENT COMPUTER FIDS FAULT ISOLATION DETECTION SYSTEM
DSCS DOOR AND SCAPE SLIDES CONTROL SYSTEM FMA FLIGHT MODE ANNUNCIATOR
EADI ELECTRONIC ATTITUDE DIRECTOR INDICATOR FMGEC FLIGHT MANAGENT GUIDANCE ENVELOP COMPT
ECAM ELECTRONIC CENTRALIZED AIRCRAFT MONITORI FMGES FLIGHT MANAGENT GUIDANCE ENVELOPE SYS
ECP ECAM CONTROL PANEL FMV FUEL METERING VALVE
ECS ENVIRONMENTAL CONTROL SYSTEM FPEEPMS FLOOR PROXIMITY EMRG. ESCAP PATH MK. SYS
EEC ENGINE ELECTRONIC CONTROL GCR GENERATOR CONTROL RELAY
EFCC/S ELECTRONIC FLIGHT CONTROL COMPUTER/SYST. HCU HYDRAULIC CONTROL UNIT
EGIU ELECTRICAL GENERATOR INTERFACE UNIT HEGS HYDRAULIC ELECTRICAL GENERATING SYSTEM
EIU ENGINE INTERFACE UNIT HMU HYDROMECHANICAL UNIT
EIUVMU ENGINE INTERFACE/VIBRATION MONIT. UNIT HPTACC HIGH PRESSURE TURBINE ACTIVE CLEARNCE CTL
ELAC ELEVATOR AILERON COMPUTER HSMU HYDRAULIC SYSTEM MONITORING UNIT
EMLS EMERGENCY LIGHTING SYSTEM LA LINEAR ACCELEROMETER
EMU ENGINE MAINTENANCE UNIT LCIT LOAD COMPRESSOR INLET TEMPERATURE
ABREVIATURAS A319/320 ABREVIATURAS A319/320
LGCIU LANDING GEAR CONTROL INTERFACE UNIT RAT RAM A IR TURBINE
LLDC LOW LEVEL DIRECT CURRENT VOLTAGE RCCB REMOTE CONTROL CIRCUIT BREAKER
LMS LEAKAGE MEASUREMENT SYSTEM RLA REVERSER LEVER ANGLE
LOP LOW OIL PRESSURE RMP RADIO MANGEMENT PANEL
LPTACC LOW PRESS TURBINE ACTIVE CLEARENCE CTL SDAC SYSTEM DATA ACQUISITION CONCENTRATOR
LVDT LINEAR VARIABLE DIFFERENTIAL TRANSDUCER SDCU SMOKE DETECTION CONTROL UNIT
MCDU MULTIPURPOSE CONTROL DISPLAY UNIT SFCC SLAT FLAP CONTROL COMPUTER
MDDU MULTIPURPOSE CONTROL DISPLAY UNIT SIC SYSTEM ISOLATION CONTACTOR
MÊS MAIN ENGINE START SSTU SIDE STICK TRANSDUCER UNIT
MICBAC MICRO-SYSTEM BUS ACCESS CHANNEL TCAS TRAFFIC ALERT COLLISION AVOIDANCE SYSTEM
MMR MLTI MODE RECEIVER THS TRIMMABLE HORIZONTAL STABILIZER
MSU MODE SELECTOR UNIT(IRS) TLA THROTTLE LEVER ANGLE
MSW MICROSWITCH TLU TRAVEL LIMITATION UNIT
N/WS NOSE WHEEL STEERING TRA THROTTLE RESOLVER ANGLE
OMS ONBOARD MAINTENANCE SYSTEM TRDV THRUST REVERSER DIRECTINAL VALVE
OOT OIL OUTLET TEMPERATURE TRPV THRUST REVERSER PRESSURIZING VALVE
OPV OVERPRESURE VALVE TTS TRIM TANK SYSTEM
PC PACK CONTROLLER VBV VARIABLE BLEED VALVE
PCU PASSANGER CONTROL UNIT VCO VOLTAGE CONTROLLED OSCILLATOR
PCU POWER CONTROL UNIT VCU VIDEO CONTROL UNIT
PES PASSANGER ENTERTAINMENT SYSTEM WBC/S WEIGHT AND BALANCE COMPUTER/SYSTEM
PHC PROBE HEAT COMPUTER WHC WINDOW HEAT COMPUTER
PIU PASSENGER INFORMATION UNIT WIPCU WATER ICE PROTECTION CONTROL UNIT
PSCU PROXIMITY SWITCH CONTROL UNIT WIPDU WATER ICE PROTECTION DATA UNIT
PSDU POWER SUPPLY DECOUPLING UNIT WTB WING TIP BRAKE
PSS/U PASSENGER SERVICES SYSTEM/UNI WXR WEATHER RADAR
PVIS PASSENGER VISUAL INFORMATION SYSTEM XDCR TRANSDUCER
RACC ROTOR ACTIVE CLEARENCE CONTROL ZFCG ZERO FUEL CENTER OF GRAVITY
RACSB ROTOR ACTIVE CLEARENCE START BLEED
A319/320
PRESSÃO DOS PNEUS
MAIN LANDING GEAR
210 PSI

NOSE LANDING GEAR


178 PSI

MAIN LANDING GEAR


168 A 189 TROCAR PNEU

NOSE LANDING GEAR


143 A 161 TROCAR PNEU

MAIN LANDING GEAR


0 A 168 TROCAR O PAR

NOSE LANDING GEAR


0 A 143 TROCAR O PAR

TORQUE DAS RODAS


LOCK BOLT 35.39 A 39.89 Lbs/Pol

MLG 1° 300.14 Lbs/Ft


2° 149.70 Lbs/Ft

NLG 1º 160.76 Lbs/Ft


2º 80.01 Lbs/Ft
FONTE:LINE CHECK SUPPORTING DATA
MAX. DEFASAGEM DE IND. ALTITUDE A-319 MAX. DEFASAGEM DE IND. ALTITUDE A-319
ADR 1 ADR1/ 2/ STDBY ADR 1 ADR1/ 2/ STDBY
FLIGHT SPEED ADR 2 Ft 3 Ft ALT ADR FLIGHT SPEED ADR 2 Ft 3 Ft ALT ADR
LEVEL NO PFD NO PFD 1/2 3 Ft LEVEL NO PFD NO PFD 1/2 3 Ft
GND --------- 20 20 ------ GND ------- 6 6 6
50 CAS 250 50 65 125 50 CAS 250 4 4 7
KTS KTS
100 CAS 250 55 80 185 100 CAS 250 4 5 8
KTS KTS
200 CAS 300 90 135 295 200 CAS 300 3 5 9
KTS KTS
300 MACH 0.78 130 195 390 300 MACH 0.78 3 5 9
390 MACH 0.78 130 195 445 390 MACH 0.78 3 4 8
REF: D.E. A31934-001/ 34-13-00-810-998 REF: D.E. A31934-002/ 34-13-00-810-998

MAX. DEFASAGEM DE IND. ALTITUDE A-320 MAX. DEFASAGEM DE IND. AIRSPEED A-320
ADR 1 ADR1/ 2/ STDBY ADR 1 ADR1/ 2/ STDBY
FLIGHT SPEED ADR 2 Ft 3 Ft ALT ADR FLIGHT SPEED ADR 2 Ft 3 Ft AIS ADR
LEVEL NO PFD NO PFD 1/2 /3 Ft LEVEL NO PFD NO PFD 1/2/3 Ft
GND --------- 20 20 ------- GND ------- 6 6 6
50 CAS 250 50 65 130 50 CAS 250 4 4 7
KTS KTS
100 CAS 250 55 80 185 100 CAS 250 4 5 8
KTS KTS
200 CAS 300 90 135 295 200 CAS 300 3 5 9
KTS KTS
300 MACH 0.78 130 195 390 300 MACH 0.78 3 5 9
390 MACH 0.78 130 195 445 390 MACH 0.78 3 4 8
REF: D.E. A32034-001/ 34-13-00-810-998 REF: D.E. A32034-002/ 34-13-00-810-998
INGLÊS TÉCNICO INGLÊS TÉCNICO
REFERÊNCIA RÁPIDA REFERÊNCIA RÁPIDA
01-ACCOMPLISHED THRU CHECK 01-EFETUADA INSP. DE TRÂNSITO
02-ACCOMPLISHED DAILY CHECK 02-REALIZADO CHECK DIÁRIO
03-ACCOMPLISHED WEEKLY CHECK 03-REALIZADO CHECK SEMANAL
04-ACFT DISPATCHED ACCORDING MEL... 04-ACFT DESPACHADA DE ACORDO MEL...
05-NO AVAILABLE SPARE PART 05-Ñ POSSUÍMOS MATERIAL ESTQ
06-PERFOMED OPERATIONAL TEST ON GROUND 06-EFETUADO TESTE OPERACIONAL NO SOLO...
...NO FAULTS FOUND ...NENHUMA PANE FOI ACHADA...
...THE SYSTEM IS OK ...O SISTEMA ESTA OK
07-SWAPPED ( )WITH( )... 07-FOI INVERTIDO( )COM( )...
...TO BE REASEARCHED ...PARA SER PESQUISADO
...BOTH SYSTEM WORKED NORMAL ON GROUND ...NO SOLO AMBOS SIST. OPERAM NORMALMENT
...THE FAULT REMAIN ...A PANE AINDA CONTINUA
...THE CHANGEND OF SIDE ...A PANE INVETEU DE LADO
08-PERFORMED TROUBLESHOOTING 08-FEITO PESQUISA
...THE FAULTS ...A PANE E...
09-REPLACED ( ) AND OPERATIONAL TEST... 09-FOI SUBST.( ) E FEITO TESTE OPERACIONAL
...ACCORDING TO MAINT. MANUAL ...DE ACORDO MANUAL MNT
...IN UNIT(SELF TEST) ...NA UNIDADE
10-REPLACED NOSE WHEEL (LH/RH) /MAIN WHEEL DUE... 10-SUBST. RODA DE NARIZ (LH/RH) / TREM PRINC.
...NORMAL WEAR DEVIDO...
...DEEP CUT ...DESGASTE NORMAL
...LEAKAGE ...CORTE PROFUNDO
11-REPALCED BRAKE # DUE... ...VAZAMENTO
...NORMAL WEAR 11-SUBTITUIDO FREIO # DEVIDO
...DESGASTE NORMAL
...LEAKAGE ...VAZAMENTO
12-THE PLUG... 12-O PLUG(CONECTOR)...
...HAS BEEN CLANED ...FOI LIMPO
...HAS BEEN LOCKED ...FOI TRAVADO
13-SENSOR WITH ERRONEUS(FALSE) INDICATIONS 13-SENSOR COM INDICAÇÃO ERRONEA
14-MISSING 14-FALTANDO
15-DEACTIVETED HYDRAULIC PUMP ON ENG # DUE... 15-DASATIVADA BOMBA HID.(LH/RH) DO MOTOR #
DEVIDO...
...LEAKEGE ...VAZAMENTO
16-RETORQUED THE LINES, AFTER TEST OK 16-EFETUADO REAPERTO DAS LINHAS APÓS TESTE OK.
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
VENT AVIONCS VU 122 AVNCS VENT MONG VENT AVIONCS VU 122 Y17 AVNCS VENT MONG
FAULTS EXTRACT FAULT IF NO HELP, THEN RESET:
IF NO HELP, THEN RESET VU 49 D5 AVNCS VENT CTL
21 21 VU 49 D6 AVNCS VENT CTL
VU 49 D5 AVNCS VENT CTL IF NO HELP, THEN RESET:
VU 49 D6 AVNCS VENT CTL VU 123 AE2 AVNCS VENT EXTC
FAN
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:1S HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:1S
A/C CONFIGURATION: A/C CONFIGURATION:
A/C ON GROUND AND A/C ON GROUND AND
BLOWER AND EXTRACT PUSH-BUTTONS ON VENTILATION BLOWER AND EXTRACT PUSH-BUTTONS ON VENTILATION
PANEL:AUTO PANEL:AUTO
DITCHING PUSH-BUTTON: OFF DITCHING PUSH-BUTTON: OFF

2-DURATION:85 SEC 2-DURATION:85 SEC


FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
BLOWER AND EXTRACT LOCAL FAULTS BLOWER AND EXTRACT LOCAL FAULTS
SMOKE AT GEN 1 LINE SMOKE AT GEN 1 LINE
SKIN VALVES MOVING TO FULLY OPEN POSITION SKIN VALVES MOVING TO FULLY OPEN POSITION

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
COND. TRIM AIR DISREGARD IF THE WARNING CABIN TRIM AIR VU 122 V17 ZON TEMP CTLSYS 1
SYS FAULT AND AND MSG “TRIM AIR HI PR” VALVE MSG VU 122 V18 ZON TEMP CTLSYS 2
MSG “TRIM AIR HI IS TRIGGERED WHEN ALL TRIM VU 122 V19 ZON TEMP CTLSYS 1
21 21
PR” AIR VALVES ARE CLOSED VU 122 V20 ZON TEMP CTLSYS 2
REF FLT MANUAL 7-60 RESET CB IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
3-RESULTS OF POWER-UP TESTS 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

TESTS PASS: HOW LONG THE COMPTER MUST BE DE-ENERGIZED:200S


ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED A/C CONFIGURATION:
A/C ON GROUND AND
TESTS FAIL: (FAULT CONFIRMED) BOTH PACK SELECTED: OFF
PROCEED TO MEL/TSM FOR FLOW CONTROL VALVES: CLOSED
DEFERAL/TROUBLESHOOTING
NOTE: BOTH PACK CONTROLLERS ENERGIZED AND
HAVING FINISHED THEIR POWER-UP TESTS PLUS 5 SEC.
DELAY FOR CONFIRMATION

2-PROGRESS OF POWER-UP TESTS


DURATION: 36 SEC.
FLIGHT DECK EFFECTS:
3 TRIM AIR VALVES ARE MOVING FROM COOL TO HOT
AND FROM HOT TO COOL.

3-RESULTS OF POWER-UP TESTS


TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET
MSG
AUTO FLIGHT MSG IS DISPLAYED WHEN AUTO
A/THR LIMITED THR ENGAGED AND THE
WARNING MSG THROTTLES ARE BELOW THE
22 CL DETENT.
MOVE THROTTLES PER FLT
MANUAL 7-50

ATA PROBLEM OR CB TO RESET


MSG
AUTO FLT A/THR UPPER ECAM MSG AFTER
OFF MSG ENGINE START AND BEFORE T.O.
22 THRUST IS APPLIED (ON THE
GROUND).
THIS MSG SHOULD DE
DISREGARDED BY FLIGHT
CREW PER FLT MANUAL 7-50
3-RESULTS OF POWER-UP TESTS

TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FCU FAULTS VU 49 B5 FCU1 FMGC MSG VU 49 B2 FMGC 1
VU 121 M21 FCU2 “OPPOSITE FM IN VU 121 M17 FMGC 2
RESET CB’S IN ACCORDANCE
22 22 PROGRESS OF VU 49 D6 AVNCS VENT CTL
WITH THE FOLLOWING FMA SHOWS RESET CB’S IN ACCORDANCE WITH
PROCEDURE OFFSIDE FD’S” THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >7 HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4
MIN ON BOTH FCU’S SEC.
A/C CONFIGURATION: A/C CONFIGURATION:
A/C ON GROUND A/C ON GROUND WITH ENGINES STOPPED

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 10 SEC DURATION:120 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
ECAM STATUS PAGE: FCU 1&2 INOP – AP 1&2 INOP – A/THR ECAM STATUS PAGE: AP 1&2 INOP
INOP

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FMGC MSG “SET VU 49 B2 FMGC 1 AUTO PILOT #1 VU 49 B2 FMGC 1
OFFSIDE RANGE VU 121 M17 FMGCU 2 FAULT RESET CB’S IN ACCORDANCE WITH
MODE” RESET CB’S IN ACCORDANCE WITH THE FOLLOWING PROCEDURE
22 THE FOLLOWING PROCEDURE 22
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >1 HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4
SEC SEC.
A/C CONFIGURATION: A/C CONFIGURATION:
A/C ON GROUND A/C ON GROUND WITH ENGINES STOPPED

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 120 SEC DURATION:120 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
ECAM STATUS PAGE: AP# 1 E 2 INOP ECAM STATUS PAGE: AP #1 E 2 INOP

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
AUTO PILOT #2 VU 121 M17 FMGCU 2 FAC FAULTS RESET FAC#1 PUSHBUTTON
FAULT RESET CB’S IN ACCORDANCE WITH 22 SYSTEM #1 IF NO HELP, THEN RESET
22 THE FOLLOWING PROCEDURE VU 49 B3 FAC 1 26 VAC
VU 49 B4 FAC 1 28 VDC
RESET CB’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4 HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4
SEC SEC.
A/C CONFIGURATION: A/C CONFIGURATION:
A/C ON GROUND WITH ENGINES STOPPED 1-A/C ON GROUND WITH ENGINES STOPPED FOR
ELECTRICAL POWER-UP TESTS,
2- PROGRESS OF POWER-UP TESTS 2-A/C ON GORUND AND HYDRAULICALLY ENERGIZED FOR
DURATION: 120 SEC YAW DAMPER POWER LOOP POWER-UP TESTS
FLIGHT DECK EFFECTS:
ECAM STATUS PAGE: AP# 1 E 2 INOP 2- PROGRESS OF POWER-UP TESTS
DURATION:1 –90 SEC
3-RESULTS OF POWER-UP TESTS 2 –5 SEC
TESTS PASS: FLIGHT DECK EFFECTS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED AUTO FLT RUDDER TRIM 1(2)
AUTO FLT RUD TRAV LIM 192)
TESTS FAIL: (FAULT CONFIRMED) AUTO FLT YAW DAMPER 1(2)
PROCEED TO MEL/TSM FOR FLT CTL PANEL: FAULT FLASHES ON FAC 1 PUSHBUTTON
DEFERAL/TROUBLESHOOTING
3-RESULTS OF POWER-UP TESTS
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FAC FAULTS RESET FAC#2 PUSHBUTTON DUAL CAT III MSG VU 49 B4 FAC 1 28 VAC
SYSTEM #2 IF NO HELP, THEN RESET 22 VU 121 M19 FAC 2 28 VDC
22 VU 49 B3 FAC 1 26 VAC RESET CB’S IN ACCORDANCE WITH
VU 121 M19 FAC 2 28 VDC THE FOLLOWING PROCEDURE
RESET CB’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4 HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4
SEC. SEC.
A/C CONFIGURATION: A/C CONFIGURATION:
1-A/C ON GROUND WITH ENGINES STOPPED FOR 1-A/C ON GROUND WITH ENGINES STOPPED FOR
ELECTRICAL POWER-UP TESTS, ELECTRICAL POWER-UP TESTS,
2-A/C ON GORUND AND HYDRAULICALLY ENERGIZED FOR 2-A/C ON GORUND AND HYDRAULICALLY ENERGIZED FOR
YAW DAMPER POWER LOOP POWER-UP TESTS YAW DAMPER POWER LOOP POWER-UP TESTS

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION:1 –90 SEC DURATION:1 –90 SEC
2 –5 SEC 2 –5 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
AUTO FLT RUDDER TRIM 1(2) AUTO FLT RUDDER TRIM 1(2)
AUTO FLT RUD TRAV LIM 1(2) AUTO FLT RUD TRAV LIM 192)
AUTO FLT YAW DAMPER 1(2) AUTO FLT YAW DAMPER 1(2)
FLT CTL PANEL: FAULT FLASHES ON FAC 2 PUSHBUTTON FLT CTL PANEL: FAULT LEGEND FLASHES

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
MCDU FAULT VU 49 B1 MCDU 1 MCDU FAULT VU 121 N20 MCDU 2
SYSTEM #1 RESET CB’S IN ACCORDANCE WITH 22 SYSTEM #2 RESET CB’S IN ACCORDANCE WITH
22 THE FOLLOWING PROCEDURE THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
>200 MS. >200 MS.
A/C CONFIGURATION: A/C CONFIGURATION:
A/C ON GROUND A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION:45 SEC DURATION:45 SEC

FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:


MCDU SCREEN IS BLANK MCDU SCREEN IS BLANK

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED)
TESTS FAIL: (FAULT CONFIRMED) PROCEED TO MEL/TSM FOR
PROCEED TO MEL/TSM FOR DEFERAL/TROUBLESHOOTING
DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
AUTO FLT RUD RESET FAC 1 AND FAC 2 RUDDER TRAVEL VU 49 B3 FAC 1 26VAC
TRV LIM SYS PUSHBUTTON SWITCHES 22 LIMIT SYSTEM #1 VU 49 B4 FAC 2 28VDC
22 FAULT MSG IF NO HELP, THEN RESET:
VU 49 B2 FMGC 1 (SEE CH 22,
AP#1 FAULT FOR PROCEDURE)
RESET CB’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
3-RESULTS OF POWER-UP TESTS 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED SEC.
A/C CONFIGURATION:
TESTS FAIL: (FAULT CONFIRMED) 1-A/C ON GROUND WITH ENGINES STOPPED FOR
PROCEED TO MEL/TSM FOR ELECTRICAL POWER-UP TESTS,
DEFERAL/TROUBLESHOOTING 2-A/C ON GORUND AND HYDRAULICALLY ENERGIZED FOR
YAW DAMPER POWER LOOP POWER-UP TESTS

2- PROGRESS OF POWER-UP TESTS


DURATION:1 –90 SEC
2 –5 SEC
FLIGHT DECK EFFECTS:
AUTO FLT RUDDER TRIM 1(2)
AUTO FLT RUD TRAV LIM 192)
AUTO FLT YAW DAMPER 1(2)
FLT CTL PANEL: FAULT LEGEND FLASHES

3-RESULTS OF POWER-UP TESTS


TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
RUDDER TRAVEL VU 121 M18 FAC 2 26VAC CIDS SYSTEM ATTEMPT A RESET AT PTP FIRST,
LIMIT SYSTEM #2 VU 121 M19 FAC 2 28VDC 23 FAULTS IF NO HELP, THEN RESET: NOTE
22 IF NO HELP, THEN RESET: RESET C.B.’S TOGETHER
VU 121 M17 FMGC 2 (SEE CH 22, AP VU 49 G2 CID DIR 1&2 ESS
#2 FAULT FOR PROCEDURE) VU 121 M5 CIDS DIR 1&2 NORM
RESET CB’S IN ACCORDANCE WITH RESET CB’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: 1-
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4 10 SEC; 2- 30 SEC.
SEC. A/C CONFIGURATION:
A/C CONFIGURATION: 1-A/C ON GROUND WITH BOTH CABIN DOORS CLOSED
1-A/C ON GROUND WITH ENGINES STOPPED FOR 2-A/C ON GROUND WITH ENGINES STOPPED AND A CABIN
ELECTRICAL POWER-UP TESTS, DOOR OPEN
2-A/C ON GORUND AND HYDRAULICALLY ENERGIZED FOR 2- PROGRESS OF POWER-UP TESTS
YAW DAMPER POWER LOOP POWER-UP TESTS DURATION:1 –50 SEC
2- PROGRESS OF POWER-UP TESTS 2 –120 SEC
DURATION:1 –90 SEC FLIGHT DECK EFFECTS:
2 –5 SEC CIDS 1 ON THEN OFF AFTER 30 SEC
FLIGHT DECK EFFECTS: CIDS 2 ON THEN OFF AFTER 80 SEC
AUTO FLT RUDDER TRIM 1(2) AUDIO CONTROL PANEL “ATT LIGHT IS FLASHING”
AUTO FLT RUD TRAV LIM 1(2)
AUTO FLT YAW DAMPER 1(2) CABIN AFFECTS:
FLT CTL PANEL: FAULT LEGEND FLASHES 1- CABIN LIGHTS ARE OFF DURING 1SEC
2-CABIN LIGHTS AND PAX ATT LIGHTS ARE FLASHING
3-RESULTS OF POWER-UP TESTS
TESTS PASS: 3-RESULTS OF POWER-UP TESTS
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED TESTS PASS:
TESTS FAIL: (FAULT CONFIRMED) ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
PROCEED TO MEL/TSM FOR DEFERAL/TS TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
23 FLT ATTND/PNL VU 121 M14 CIDS FWD
LOCKED UP ATTND/PNL

ATA PROBLEM OR CB TO RESET


MSG
PAX VU 2000 F6 CABIN COM SYS PES
23 ENTERTAINMENT IF NO HELP, THEN RESET: ALL
WILL NOT TURN DEU’S
ON OR OFF VU 121 M7 THROUGH M13

ATA PROBLEM OR CB TO RESET


MSG
23 PAX SEAT AUDIO VU 2000 CABIN COM SYS PES
INOP

ATA PROBLEM OR CB TO RESET


MSG
SEAT VIDEO SYS RESET INDIVIDUAL VIDEO UNIT,
UNIT PROBLEMS SMALL HOLE JUST FWD OF
23 SCREEN ON THE SAME PANEL IS
RESET BUTTON(ON-
OFF)

ATA PROBLEM OR CB TO RESET


MSG
23 RMP FAULTS TURN AFFECTED RMP OFF THEN
ON TO RESET
ATA PROBLEM OR CB TO RESET
MSG
ACP FREQ’S WILL TRUN AFFECTED RMP OFF THEN
23 NOT CHANGE ON TO RESET
FROM THE IF NO HELP, THEN RESET:
STANDBY TO VU 49 B2 FMGC 1
ACTIVE WINDOWS VU 121 M17 FMGC 2
RESET CB’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE

1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: >4


SEC.
A/C CONFIGURATION:
A/C ON GROUND WITH ENGINES STOPPED

2- PROGRESS OF POWER-UP TESTS


DURATION:120 SEC

FLIGHT DECK EFFECTS:


ECAM STATUS PAGE: AP 1(2) INOP

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET
MSG
23 TCAS INOP MSG VU 121 K10 TCAS
NOTE SYS TEST THRU MCDU
ALSO WORKS

ATA PROBLEM OR CB TO RESET


MSG
COM VHF CHECK:
23 EMITTING FAULT TRANSMITION KEY ON AUDIO
PANEL
SIDE STICK RADIO SEL
HAND MIKE SEL NOT IN TRANS
POSITION
IF NOT FOUND IN TRANS POS
RESET:
VU 49 G9 VHF 1*
VU 121 L4 VHF 2*
VU 121 L5 VHF 3*
IF NO HELP LEAVE C.B.
OPEN(PULLED)* REF FLIGHT
MANUAL 7-58

ATA PROBLEM OR CB TO RESET


MSG
23 VHF SYSTEM INOP VU 49 G9 VHF 1(SYS1)
VU 121 L4 VHF 2(SYS2)
VU 121 L5 VHF3(SYS3)
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
ECAM MSG NO REQUIREMENT ENGINE 1(2) ENGINE (S) MUST BE SHUT
RELATED TO HOWEVER, IF TIME PERMITS 24 GENERATOR ON DOWN
24 TRIPPED GREEN RESET MAY BE ATTEMPTED, LINE (GREEN VU 122 T26 GCU 1 (ENG 1)
CB’S IF UNSUCCESFUL, DO NOT LINE) AND VU 122 T27 GCU 2 (ENG 2)
MAKE A SECOND ATTEMPET PARAMETERS NOT RESET CB’S IN ACCORDANCE WITH
FLT MANUAL 7-57 SHOWN THE FOLLOWING PROCEDURE
3-RESULTS OF POWER-UP TESTS 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED 15MS.
A/C CONFIGURATION:
TESTS FAIL: (FAULT CONFIRMED) 1-A/C ON GROUND WITH ENGINES STOPPED
PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTIMG 2- PROGRESS OF POWER-UP TESTS
DURATION: 30 MS

FLIGHT DECK EFFECTS:


NONE

3-RESULTS OF POWER-UP TESTS


TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
NO “AVAIL” ENGINES AND APU SHUT DOWN BATTERY CHARGE RESET SHIPS BATTERIES ONE AT
GREEN LEGEND AND GROUND POWER 24 LIMITER (BCL) A TIME WITH APU OPERATING
24 DISPLAYED ON CONNECTED IF HELP, THEN RESET:
“EXT PWR” VU 122 Y24 GPCU VU 105 N/A BAT REF BLC 1
PUSHBUTTON RESET CB’S IN ACCORDANCE WITH VU 105 N/A BAT BUS REF BLC 1
SWITCH THE FOLLOWING PROCEDURE VU 105 N/A BAT REF BLC 2
VU 105 N/A BAT BUS REF BLC 2
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 3-RESULTS OF POWER-UP TESTS
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
NONE
A/C CONFIGURATION: TESTS FAIL: (FAULT CONFIRMED)
1-A/C ON GROUND, ENGINES STOPPED, APU STOPPED PROCEED TO MEL/TSM FOR
GROUND POWER UNIT CONNECTED TO THE A/C DEFERAL/TROUBLESHOOTING

2- PROGRESS OF POWER-UP TESTS


DURATION: 35 MS

FLIGHT DECK EFFECTS:


NONE

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
TRANSFORMER RESET T/R THROUGH MCDU OR CREW SEAT VU 122 U11 CKPT SEAT CTL CAPT
RECTIFIER RESET ALL THREE USING 25 PROBLEMS VU 122 U14 CKPT SEAT CTL F/O
24 FAULTS GUARDED BUTTON ON 103 VU ADDTIONAL C.B. IS LOCATED
PANEL IN ELECTRICAL BAY UNDER EACH SEAT ON THE
CONTROL BOX
3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS
TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING DEFERAL/TROUBLESHOOTING
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FWD AND AFT VU 49 C6 SDCU CHAN 1 FWD AND AFT VU 49 AFT CARGO VENT&HEAT
CARGO DETECT VU 122 T18 SDCU CHAN2 26 CARGO HEAT CTL/MONG
26 MSGS NOTE: RESET C.B.’S TOGETHER DETECT FAULTS VU 122 S22 AFT CARGO
IF NO HELP, THEN RESET: VENT&HTG FAN
VU 49 C6 SDCU CHAN1 RESET C.B.’S IN ACCORDANCE WITH
VU 122 T18 SDCU CHAN 2 THE FOLLOWING PROCEDURE
VU 49 AFT CARGO VENT&HTG
FAN
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
200 MS 200 MS
A/C CONFIGURATION: A/C CONFIGURATION:
1-A/C ON GROUND 1-A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 10 SEC DURATION: 10 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
NONE NONE

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
LAV SMOKE VU 49 C6 SDCU CHAN 1 SIDE STICK FAC 1&2 SWITCHES
DETECT MSG VU 122 T18 SDCU CHAN2 27 PRIORTY MSG SEC 1,2&3 SWITCHES
26 RESET C.B.’S IN ACCORDANCE WITH ELAC 1&2 SWITCHES
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 3-RESULTS OF POWER-UP TESTS
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
200 MS ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
A/C CONFIGURATION:
1-A/C ON GROUND TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
2- PROGRESS OF POWER-UP TESTS
DURATION: 10 SEC
FLIGHT DECK EFFECTS:
NONE

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
SEC 1,2 OR 3 USE PUSH BUTTON SWITCHES FIRST ELAC 1 OR 2 USE PUSH BUTTON SWITCHES FIRST
FAULTS IF NO HELP, THEN RESET FAULTS IF NO HELP, THEN RESET
27 27
VU 49 B8 1 NORM SPLY SEC 1 VU49 B11 ELAC1 NORM SPLY ELAC 1
VU105 N/A SEC1 STBY SPLY SEC1 VU105 N/A ELAC1 STBY SPLY ELAC1
VU 121 Q18 SEC 2 SPLY SEC 2 VU121 R20 ELAC2 SPLY ELAC 2
VU105 N/A ELAC2 STBY SPLY ELAC2
VU 121 Q19 SEC 3 SPLY SEC3 RESET C.B.’S IN ACCORDANCE WITH
RESET C.B.’S IN ACCORDANCE WITH THE FOLLOWING PROCEDURE
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: 30
5SEC MS BY C/B OR RESET PUSHBUTTON OFF THEN ON
A/C CONFIGURATION: A/C CONFIGURATION:
HYDRAULIC SYSTEM DE-PRESSURIZED HYDRAULIC SYSTEM DE-PRESSURIZED

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 18 SEC DURATION: 8 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
ECAM F/CTL PAGE: SEC AMBER IND., ASSOCIATED ECAM F/CTL PAGE: ELAC AMBER INDICATION AND
ELEVATORS CROSSED, ASSOCIATED SPOILERS AMBER ASSOCIATED AILERON SERVO CONTROL AMBER BOXED
CROSSED THEN FLASHING AT THE END OF THE TEST. ECAM WARNING: F/CTL ELAC1(2) FAULT DISPLAYED
ECAM WARNING:F/CTL SEC 1(2)(3) FAULT DURING DURING 8 SEC. IF SUBSEQUENT TO C/B RESET
AROUND 23 SEC. NOTE: NONE IF SUBSEQUENT TO PUSHBUTTON RESET
FLT CONTROL PANEL: SEC FAULT LEGEND IS FLASHING FLT CONTROL PANEL:FAULT LEGEND ILLUMINATED
AT THE BEGINNING AND AT THE END OF TEST. DURING 8SEC.
3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS
TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
27 FLIGHT CONTROL MUST PERFOMED WING TIP
FLAPS LOCKED BRAKE(WTB) RESET THROUGH
OUT MCDU PER AMM 27-50-00 PG 209-
211 (HYD MUST BE OFF)

ATA PROBLEM OR CB TO RESET


MSG
FLT/CTL MSG VU 49 B6 SLT CTL & MONG SYS 1
27 WITH SLAT/FLAP VU 49 B7 FLP CTL 7 MONG SYS 1
FAULTS VU 121 R21 SLT CTL SYS 2
VU 121 Q21 FLP CTL & MONG SYS
2
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: 200


MS
A/C CONFIGURATION:
A/C ON GROUND WITH ENGINES STOPPED AND NEW DATE
FROM CFDS
2- PROGRESS OF POWER-UP TESTS
DURATION: 2 SEC
FLIGHT DECK EFFECTS:
ECAM WARNING: IF HYDRAULIC PRESSURIZED: FLT CTL
SLAT SYS 1(2) OR FLAP SYS1(2) FAULT
IF HYDRAULIC CIRCUIT NOT PRESSURIZED:NONE
3-RESULTS OF POWER-UP TESTS
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FLT/CTL VU 49 B10 FCDC 1 SPLY SLOW SLATS VU 49 B6 SLT CTL & MONG SYS 1
MAINTENANCE VU 121 Q20 FCDC 2 SPLY 27 VU 121 R21 SLT CTL SYS 2
27 RESET C.B.’S IN ACCORDANCE WITH RESET C.B.’S IN ACCORDANCE WITH
MSG(CAN BE
DEFERRED) THE FOLLOWING PROCEDURE THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-
>3SEC ENERGIZED:>200 MS
A/C CONFIGURATION:
A/C ON GROUND AND ENGINES STOPPED A/C CONFIGURATION:
A/C ON GROUND WITH ENGINES STOPPED AND NEW DATE
2- PROGRESS OF POWER-UP TESTS FROM CFDS
DURATION: 3 SEC
FLIGHT DECK EFFECTS: 2- PROGRESS OF POWER-UP TESTS
ECAM WARNING:F/CTL FCDC 1(2) FAULT DURING 3 SEC. DURATION: 2 SEC
FLIGHT DECK EFFECTS:
3-RESULTS OF POWER-UP TESTS ECAM WARMING: IF HYDRAULIC PRESSURIZED: FLT CTL
TESTS PASS: SLAT SYS 1(2) OR FLAP SYS1(2) FAULT
IF HYDRAULIC CIRCUIT NOT PRESSURIZED:NONE
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) 3-RESULTS OF POWER-UP TESTS
PROCEED TO MEL/TSM FOR DEFERAL/TS TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FQI INOP VU 49 A13 FQI CHAN 1 FUEL APU LP CYCLING THE MASTER SWITCH
VU 121 M27 FQI CHAN 2 28 VALVE FAULT ON THEN OFF MAY CLEAR THIS
28 VU 121 L26 FQI CHAN 1&2 MSG. TRIGGERED MSG
RESET C.B.’S IN ACCORDANCE WITH WHEN THE APU REF FLT MANUAL 7-114
THE FOLLOWING PROCEDURE MASTER SW IS RESET C.B.’S IN ACCORDANCE WITH
SELECTED OFF THE FOLLOWING PROCEDURE
DURING NA EMER
SHUT DOWN OR
SHUT DOWN
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
3-RESULTS OF POWER-UP TESTS
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: TESTS PASS:
>1SEC
A/C CONFIGURATION: ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
A/C ON GROUND AND REFUEL PANEL DOOR OPEN TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
2- PROGRESS OF POWER-UP TESTS
DURATION: 80 SEC MAXIMUM
FLIGHT DECK EFFECTS:
ECAM FUEL PAGE: INTER-CELL TRANSFER VALVE
INDICATION MOVING, AMBER “XXX” IN PLACE OF FUEL
QUANTITY INDICATIONS THEN NORMAL INDICATONS ARE
DISPLAYED

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
29 HYD REVS LOW TO CLEAR: RUN ENGINES OR
PRESSURE MSG PRESSURIZE HYDRAULIC
RESERVOIRS WITH APU.
NOTE: THIS HAPPENS AFTER
WORKING ON HYDRAULIC SYSTEM

ATA PROBLEM OR CB TO RESET


MSG
29 PTU FAULTS (NOT VU 121 N34 SOL VALVE G/Y PTU
CAUSED BY CARGO
DOOR OPERATION
AFTER ENGINES
STARTS)

ATA PROBLEM OR CB TO RESET


MSG
29 PTU FAULTS SEE NOTES THAT FOLLOW
REGARDING FAULTS
FAULTS CAUSED BY CARGO RESET WITH ENGINES RUNNING:
DOOR OPERATION WITHIN A)RESET MESSAGE USING
30 SECONDS AFTER SECOND MASTER/CAUTION PUSHBUTTON
ENGINE START AND PTU SWITCHES
ECAM FAILURE MESSAGES B)SELECT HYD PAGE ON ECAM
NOTE: THIS PROCEDURE C)SELECT Y HYD ELEC PMP ON
WILL NOT RESET REAL PTU D)SELECT Y HYD ELEC PMP OFF
FAILURES OR HIDE REAL E)WAIT A MINIMUN OF 30 SEC
FAULTS IN THE PTU SYSTEM F)CYCLE PTU SWITCH FROM ON TO
OFF TO ON
G)SELECT#1 ENGINE GREEN HYD
PMP OFF
H)SELECT#1 ENGINE GREEN HYD
PMP ON
I)SELECT#2 ENGINE Y HYD PMP OFF
PTU SHOULD OPERATE GREEN TO
YELLOW
J)SELECT#2 ENGINE YELLOW HYD
PMP ON
K)ECAM SHOULD BE NORMAL
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
ANTI ICE L ( R ) IF THE WARNING OCCURS ON WINDSHIELD VU 122 X13 1(LEFT SIDE)
WINDSHIELD THE GROUND WITH OAT 30 HEAT FAULTS VU 122 X14 WINDOW L HEAT
30
GREATER THAN 40 DEG C AND VU 122 W13 WHC 2 (RIGHT SIDE)
AC PACKS OFF, 5 MIN AFTER VU 122 W14 WINDOWS R HEAT
BOTH PACKS ARE SELECTED RESET C.B.’S IN ACCORDANCE WITH
ON, RESET CB’S THE FOLLOWING PROCEDURE
VU 121 X13 WHC 1 (LEFT SIDE)
VU 122 W13 WHC 2 (RIGHT SIDE)
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
5SEC 5SEC
A/C CONFIGURATION: A/C CONFIGURATION:
A/C ON GROUND A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 5 SEC DURATION: 5 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
NONE NONE

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
FWD (AFT) DRAIN VU 2000 D1 FWD DRAIN MASTER ANTI ICE MSGS VU 49 D3 ANT ICE PROBES PHC 1
MASTER ECAM VU 2001 D5 AFT DRAIN MASTER 30 VU 122 Y12 ANTI ICE PROBES
30
MSG PHC2
VU 122 Y16 ANTI ICE PROBES
PHC 3
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
3-RESULTS OF POWER-UP TESTS 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED 1SEC
TESTS FAIL: (FAULT CONFIRMED) A/C CONFIGURATION:
PROCEED TO MEL/TSM FOR DEFERAL/TS A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS


DURATION: 2 SEC
FLIGHT DECK EFFECTS:
NONE

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
30 ANTI ICE PROBE VU49 D2 PITOT 1
MSGS SYSTEM#1 VU 122 Z13 ATATIC 1
VU49 D4 AOA 1
VU 122 Z12 TAT 1
IF NO HELP, THEN RESET:
VU49 F7 ADIRU 1&AOA 26 VAC
VU49 T6 ADIRU 1 115 VA
VU 105 N/A ADIRU 1 28 VDC

ATA PROBLEM OR CB TO RESET


MSG
30 ANTI ICE PROBE VU 122 Y14 PITOT 2
MSGS SYSTEM #2 VU 122 Y11 STATIC 2
VU 122 Y13 AOA 2
VU 122 Y15 TAT 2
IF NO HELP, THEN RESET:
VU 121 N9 ADIRU 2 26VAC& AOA
VU 121 N7 ADIRU 2 115 VAC
VU121 N5 ADIRU 2 28 VDC
VU 121 N11 ADIRU 2 PWR SHED

ATA PROBLEM OR CB TO RESET


MSG
30 ANTI I CE PROBE VU 122 Z16 PITOT 3
MSGS SYSTEM #3 VU 122 Z14 STATIC 3
VU 122 Z15 AOA 3
IF NO HELP, THEN RESET:
VU 121 N8 ADIRU 3 26VAC& AOA
VU 121 N6 ADIRU 3 115 VAC
VU 121 N4 ADIRU 3 28 VDC
VU 49 F9 ADIRU 3 STWG SPLY
VU 121 N10 ADIRU 3 STWG SPLY
3-RESULTS OF POWER-UP TESTS
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
DMC FAULT MSG VU 49 E11 EIS DMC 1 SPLY (SYS1 UNABLE TO VU 49 E4 EIS PFD CAPT SWTG
EIS DMC 1,2 OR 3 VU 121 Q8 EIS DMC 2 SPLY(SYS) 31 SWITCH DU VU 49 E2 EIS ND CAPT SWTG
31
VU 121 Q9 EIS DMC 3 SPLY (SYS3) VU 121 R5 EIS PFD F/O SWTG
VU 49 E10 EIS DMC 3 STBY SPLY VU 121 R6 EIS ND F/O SWTG
(SYS3) VU 49 E6 EIS ECAM DU UPPER
RESET C.B.’S IN ACCORDANCE WITH SWTG
THE FOLLOWING PROCEDURE VU 49 E6 EIS ECAM DU UPPER
SWTG
VU 121 R10 ECAM DU LOWER
SWTG
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 3-RESULTS OF POWER-UP TESTS
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
>1SEC ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
A/C CONFIGURATION: TESTS FAIL: (FAULT CONFIRMED)
A/C ON GROUND PROCEED TO MEL/TSM FOR DEFERAL/TS

2- PROGRESS OF POWER-UP TESTS


DURATION: 4 SEC
FLIGHT DECK EFFECTS:
ECAM WARNING:EIS DMC 1 OR 2 OR 3 FAULT
NOTE: A DIAGONAL IS DISPLAYED ON THE THRRE
ASSOCIATED DIPLAYED UNITS

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
NO AIDS VU 121 K15 AIDS DMU & QAR ADIRU FAULT VU 49 F6 ADIRU A 115 VAC SYS1
INDICATION RESET C.B.’S IN ACCORDANCE WITH 31 VU 105 ADIRS ADIRU 1 28VDC
31 THE FOLLOWING PROCEDURE
DISPLAYED ON VU 121 N7 ADIRU 2 115VAC (SYS2)
THE MCDU MENU VU 121 N5 ADIRU 2 28VDC (SYS2)
PAGE VU 121 N6 ADIRU 3 115VAC (SYS3)
VU 121 N4 ADIRU 3 28VDC (SYS3)
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
>1SEC 15 SEC
A/C CONFIGURATION:
A/C ON GROUND A/C CONFIGURATION:
A/C ON GROUND AND IR 1(2)(3) ROTARY BUTTON
2- PROGRESS OF POWER-UP TESTS (LOCATED ON THE ADIRS PANEL) SWITCHED TO OFF FOR
DURATION: 40 SEC 15 SEC, THEN TO NAV.
FLIGHT DECK EFFECTS:
ECAM WARNING: NONE 2- PROGRESS OF POWER-UP TESTS
NOTE: A DIAGONAL IS DISPLAYED ON THE THREE DURATION: 5 SEC
ASSOCIATED DISPLAY UNITS FLIGHT DECK EFFECTS:
ADIRS PANEL: “ON BAT” LEGEND ILLUMINATED FOR 5
3-RESULTS OF POWER-UP TESTS SEC, 2 SEC AFTER POWER-UP TEST INITIALIZATION.
TESTS PASS:
AIDS PROMPT RETURNS 3-RESULTS OF POWER-UP TESTS
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
PROCEED TO MEL/TSM FOR DEFERAL/TS TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
ECAM PAGE(S) VU 49 F1 FWS FWC 1 SPLY SDAC 1 OR 2 VU 49 F2 SDAC 1 26VAC SYNC AC
LOCKED (I.E. VU121 Q7 EIS FWC 2 SPLY & QAR 31 FAULTS ESS BUS
31 DOORS-WHEELS RESET C.B.’S IN ACCORDANCE WITH VU 49 F4 SDAC 1 SPLY
ETC.) THE FOLLOWING PROCEDURE VU121 Q3 SDAC1 26VAC SYNC AC
VU121 Q4 SDAC1 26VAC SYNC AC
VU 121 P4 SDAC 1 28 VAC
VU 49 F5 SDAC1&2 28VAC ESS
BUS
VU121 Q2 SDAC2 26VAC SYNC AC
VU121 Q5 SDAC2 26VAC SYNC AC
VU 121 Q6 SDAC 2 SPLY
VU 121 P3 SDAC 2 28 VAC
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
>1SEC 1 SEC
A/C CONFIGURATION:
A/C ON GROUND A/C CONFIGURATION:
A/C ON GROUND
2- PROGRESS OF POWER-UP TESTS
DURATION: 50 SEC 2- PROGRESS OF POWER-UP TESTS
FLIGHT DECK EFFECTS: DURATION: 5 SEC
ECAM WARNING: “EIS 1(2) FWS FAULT” FLIGHT DECK EFFECTS:
ECAM WARNING: “EIS 1(2) SDAC FAULT”
3-RESULTS OF POWER-UP TESTS
TESTS PASS: 3-RESULTS OF POWER-UP TESTS
AIDS PROMPT RETURNS TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
LGCIU FAULTS VU 49 C9 L/G LGCIU SYS1 32 LGCIU FAULTS VU121 Q35 HYD LGCIU SYS 2
SYSTEM #1 VU 121 Q34 HYD LGCIU SYS 1 SYSTEM #2 RESET C.B.’S IN ACCORDANCE WITH
32 THE FOLLOWING PROCEDURE
SPLY
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
1 SEC 1 SEC

A/C CONFIGURATION: A/C CONFIGURATION:


A/C ON GROUND A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 210 MSEC DURATION: 210 MSEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
LGCIU 1 LGCIU 2
LDG GEAR PANEL “UNLK” RED INDICATIONS ARE LDG GEAR PANEL “UNLK” RED INDICATIONS ARE
FLASHING BRIEFLY FLASHING BRIEFLY
LGCIU 2: NONE LGCIU 1: NONE

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
32 BSCU FAULTS IF A/C NOT MOVING TURN NOSE
WHEEL STEERING AND ANTI-
SKD OFF THEN ON, IF NO HELP,
SEE BSCU SYSTEM FAULTS 1&2
ON FOLLOWING PAGES.
3-RESULTS OF POWER-UP TESTS
TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS

ATA PROBLEM OR CB TO RESET


MSG
32 BSCU FAULTS VU 121 M33 BSCU SYS1 SPLY
SYSTEM #1 VU 121 M34 BSCU SYS1 CTL
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:


1 SEC

A/C CONFIGURATION:
A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS


DURATION: 1 SEC
FLIGHT DECK EFFECTS:
NONE

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
BSCU FAULTS VU 121 M35 BSCU SYS2 CTL 32 NO BRAKE TEMPS VU121 M32 BRK TEMP DET UNIT
SYSTEM #2 VU 121 M36 BSCU SYS2 SPLY DISPLAYS RESET C.B.’S IN ACCORDANCE WITH
32 RESET C.B.’S IN ACCORDANCE WITH THE FOLLOWING PROCEDURE
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 3-RESULTS OF POWER-UP TESTS
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
1 SEC ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED)
A/C CONFIGURATION: PROCEED TO MEL/TSM FOR DEFERAL/TS
A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS


DURATION: 1 SEC
FLIGHT DECK EFFECTS:
NONE

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
33 NO LIGHT IN MLG VU 2001 F5 LIGHT SEC 19
WHEEL

ATA PROBLEM OR CB TO RESET


MSG
33 APU AREA LIGHTS VU 2001 F6 APU SVC LIGHT
INOP

ATA PROBLEM OR CB TO RESET


MSG
33 CABIN LIGHTS RESET #2 CIDS THROUGH MCDU
WILL NOT TURN IF NO HELP, THEN RESET:
ON VU 121 M8 THRU M13 DEU

ATA PROBLEM OR CB TO RESET


MSG
33 CABIN LIGHTS CHECK IF CORRECT LAMP
REMAINS ON INSTALLED IF CHECK CIDS
BRIGHT WHEN THROUGH THE PTP FOR FAILED
SELECTED OFF OR DEU AND RESET DEU IF
DIM POSSIBLE.
NOTE: ALL LIGHTS
CONTROLLED BY THE FAILED
DEU WILL REMIAN ON BRIGHT
3-RESULTS OF POWER-UP TESTS
TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
DAR MSG MSG MAY BE RELATED TO FLT RECORDER VU 121 K17 FCDR FDIU & QAR
MEDIA(TAPE) BEING FULL 34 PROBLEM IN RESET C.B.’S IN ACCORDANCE WITH
34 THE FOLLOWING PROCEDURE
VU 121 K15 DMU & QAR FLIGHT OR REC
VU 121 K17 FDIU & QAR MSG
VU 121 K18 ACCLM
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
1 SEC 1 SEC

A/C CONFIGURATION: A/C CONFIGURATION:


A/C ON GROUND AND ENGINES STOPPED A/C ON GROUND AND ENGINES STOPPED

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 40 SEC DURATION: 25 SEC MAX
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
MCDU “<AIDS” INDICATION DISAPPEARS ECAM WARNING:”RECORDER FDIU FAULT” IS DISPLAYED
3 SEC
3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS
TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
VU 121 P6 EIS GPWS 28VDC WINDSHEAR DET ON THE GROUND MSG MAY
VU 121 P7 EIS GPWS 115VAC FAULT OCCUR SPURIOUSLY, RESET
THIS PROBLEM MAY BE BY ILS FACS. REF FLT MANUAL 7-139
FREQ’S THAT ARE CLOSE AND ATTEMPT PUSHBUTTON
INTERFERING WITH THE GPWS SWITCHES RESET FIRST, IF NO
34 GPWS FAULTS SYSTEM 34 HELP, THEN RESET
HAVE FLT CREW TAXI FWD 2-4 VU 49 B3 FAC 1 26VAC
FEET THIS WILL CAUSE THE VU 49 B4 FAC 1 28VDC
GPWS RECHECK ITSELF AND VU 121 M18 FAC 2 26VAC
MOST CASES CLEAR ALL VU 121 M19 FAC 2 28VDC
FAULTS RESET C.B.’S IN ACCORDANCE WITH
RESET C.B.’S IN ACCORDANCE WITH THE FOLLOWING PROCEDURE
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
1 SEC >4 SEC

A/C CONFIGURATION: A/C CONFIGURATION:


A/C ON GROUND AND ENGINES STOPPED 1-A/C ON GROUND AND ENGINES STOPPED FOR
ELECTTRICAL POWER-UP TESTS
2- PROGRESS OF POWER-UP TESTS 2-A/C ON GROUND AND HYDRAULICALLY ENERGIZED FOR
DURATION: 25 SEC MAX YAW DAMPER POWER LOOP POWER-UP TESTS
FLIGHT DECK EFFECTS: 2- PROGRESS OF POWER-UP TESTS
ECAM WARNING:”RECORDER FDIU FAULT” IS DISPLAYED DURATION: 1- 90 SEC
3 SEC 2- 5 SEC
3-RESULTS OF POWER-UP TESTS FLIGHT DECK EFFECTS:
TESTS PASS: AUTO FLT RUDDER TRIM 1(2)
AUTO FLT RUD TRAV LIM 1(2)
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED FLT CTL PANEL-“FAUTL” LEGEND FLASHES
TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS 3-RESULTS OF POWER-UP TESTS
TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
O2 LOW PRESSURE INSURE CREW O2 SUPPLY
35 MSG SWITCH IS ON
3-RESULTS OF POWER-UP TESTS
TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
36 BMC VU 49 D11 AIR BLEED ENG 1
MONG(BMC 1)
VU 122 Z22 AIR BLEED ENG 2
MONG (BMC 2)

ATA PROBLEM OR CB TO RESET


MSG
36 AIR R (L) WING RESET AFFECTED BLEED
BLEED LEAK (OR PUSHBUTTON SWITCH ON TO
APU BLEED LEAK) OFF TO ON TO CLEAR MSG.
MSG AFTER REF. FLT MANUAL BULLETIN 95-
ELECTRICAL 01
TRANSIENTS AREA
LIGHTS INOP
3-RESULTS OF POWER-UP TESTS
TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
LEFT WING LEAK VU 49 D11 AIR BLEED ENG 1 RIGHT WING VU 122 Z22 AIR BLEED ENG 2
MSGS MONG(BMC 1) 36 LEAK MSG MONG(BMC 2)
36
VU 49 D12 AIR BLEED ENG 1 CTL VU 122 Z33 AIR BLEED ENG 2 CTL
RESET C.B.’S IN ACCORDANCE WITH RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
1 SEC 1 SEC

A/C CONFIGURATION: A/C CONFIGURATION:


A/C ON GROUND A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 10 SEC DURATION: 10 SEC
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
ECAM BLEED PAGE: BLEED TEMPERATURE INDICATION ECAM BLEED PAGE: BLEED TEMPERATURE INDICATION
RESET TO 0 DEG. RESET TO 0 DEG.
ENG 1 (2) BLEED AND APU BLEED PUSHBUTTON; LIGHT ENG 1 (2) BLEED AND APU BLEED PUSHBUTTON; LIGHT
FLASHING FLASHING
3-RESULTS OF POWER-UP TESTS
3-RESULTS OF POWER-UP TESTS TESTS PASS:
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED TESTS FAIL: (FAULT CONFIRMED)
TESTS FAIL: (FAULT CONFIRMED) PROCEED TO MEL/TSM FOR DEFERAL/TS
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
CROSS BLEED VU 49 D13 AIR BLEED XFEED CROSS BLEED VU 49 D11 AIR BLEED ENG 1
VALVE MSG VALVE BAT 36 FAULTS USE IN MONG(BMC 1)
36
VU 122 Z20 AIR BLEED XFEED ADDITION TO VU 49 D12 AIR BLEED ENG 1 CTL
VALVE NORMAL XFEED VALVE VU 122 Z 22 AIR BLEED ENG 1
RESET C.B.’S IN ACCORDANCE WITH FAULTS(MSG) MONG(BMC 2)
THE FOLLOWING PROCEDURE VU 122 Z33 AIR BLEED ENG2 CTL
VU 49 F4 SDAC 1 SPLY
VU 121 Q SDAC 2 SPLY
RESET C.B.’S IN ACCORDANCE WITH
THE FOLLOWING PROCEDURE
3-RESULTS OF POWER-UP TESTS 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION
TESTS PASS:
HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED 1 SEC
TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS A/C CONFIGURATION:
A/C ON GROUND

2- PROGRESS OF POWER-UP TESTS


DURATION: 5 SEC
FLIGHT DECK EFFECTS:
ECAM WARNING; “EIS SINGLE SDAC FAULT
3-RESULTS OF POWER-UP TESTS
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED

TESTS FAIL: (FAULT CONFIRMED)


PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET
MSG
38 LOSS OF WATER VU 2000 D3 WATER SYSTEM
QUANTITY

ATA PROBLEM OR CB TO RESET


MSG
38 TOILET WILL NOT VU 2001 B1 VAC TOILET SYS LAV
FLUSH VU 2001 B3 VAC TOILET SYS LAV
VU 2001 B4 VAC TOILET SYS LAV

ATA PROBLEM OR CB TO RESET


MSG
38 GALLEY WATER REMOVE AFT GALLEY RIGHT
SYS NOISE COFFEE MAKER AND PLACE
FINGER TIP OVER DRAIN TUBE,
THIS WILL RESEAT THE CHECK
VALVE
3-RESULTS OF POWER-UP TESTS
TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
APU BLEED SHUT DOWN APU AND RESET APU WILL NOT OPEN THESE C.B.’S
FAULTS C.B.’S 49 SHUT DOWN VU 121 L42 APU CTL
49
VU 121 L41 ECB SPLY
VU 121 L42 APU CTL IF NO HELP, THEN RESET;
RESET C.B.’S IN ACCORDANCE WITH VU 121 L41 ECB SPLY
THE FOLLOWING PROCEDURE
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 3-RESULTS OF POWER-UP TESTS

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: TESTS PASS:


NONE
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
A/C CONFIGURATION: TESTS FAIL: (FAULT CONFIRMED)
A/C ON GROUND AND APU STOPPED PROCEED TO MEL/TSM FOR DEFERAL/TS
APU CONTROL PANEL; MASTER SWITCH”ON’

2- PROGRESS OF POWER-UP TESTS


DURATION: 3 SEC MAX
FLIGHT DECK EFFECTS:
APU CONTROL PANEL; ‘FAULT ON MASTER SWITCH
PUSH-BUTTON

3-RESULTS OF POWER-UP TESTS


TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED


TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
APU ELEC NO SELECT APU ELEC OFF AND FADEC FAULT TRUN FADEC PUSHBUTTON
VOLTS OR FREQS RESET TO ON 73 MSGS “ENG 1(2) SWITCH ON THEN OFF TO RESET
49
IF NO HELP, THEN RESET: FADEC FAULT OR FADEC
VU 1211 Y25 ELEC APU GCU “ENG 1(2) FADEC A
IF NO HELP, THEN RESET
RESET C.B.’S IN ACCORDANCE WITH OR B FAULT VU49 A4 ENG1 FADEC A& EIU 1
THE FOLLOWING PROCEDURE NOT RELATED TO VU121 R41 ENG1 FADEC B&EIU1
REAL FAILURE VU49 A5 ENG2 FADEC A&EIU 2
VU 121 Q40 ENG2 FADEC A&EIU 2
1-CONDITIONS OF POWER-UP TESTS INITIALIZATION 1-CONDITIONS OF POWER-UP TESTS INITIALIZATION

HOW LONG THE COMPUTER MUST BE DE-ENERGIZED: HOW LONG THE COMPUTER MUST BE DE-ENERGIZED:
15 MS 1 SEC

A/C CONFIGURATION: A/C CONFIGURATION:


A/C ON GROUND AND ENGINE STOPPED A/C ON GROUND AND ENGINE STOPPED

2- PROGRESS OF POWER-UP TESTS 2- PROGRESS OF POWER-UP TESTS


DURATION: 30 MS DURATION: 2 SEC MAX
FLIGHT DECK EFFECTS: FLIGHT DECK EFFECTS:
NONE NONE

3-RESULTS OF POWER-UP TESTS 3-RESULTS OF POWER-UP TESTS


TESTS PASS:
TESTS PASS:
ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
PROCEED TO MEL/TSM FOR DEFERAL/TS TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
ATA PROBLEM OR CB TO RESET ATA PROBLEM OR CB TO RESET
MSG MSG
ENG 1(2) EPR RECOVERY OF EPR ON BOTH ENG 1(2) OIL MAINTENANCE ACTION
MODE FAULT MSG ENGINES MAY ATTEMPED BY 79 FILTER CLOG REQUIRED!
73
SWITCHING OFF EACH EXCEPT WHEN WARNING IS
ENGINE”S N1 MODE SWITCH TEMPORARILY DISPLAYED
REF FLT MANUAL 7-86 DURING ENGINE START WITH
ENGINE OLI TEMP. BETWEEM
10° - 32° C
REF. FLT MANUAL 7-80
3-RESULTS OF POWER-UP TESTS
3-RESULTS OF POWER-UP TESTS
TESTS PASS: TESTS PASS:

ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED ABOVE MENTIONED FAULT MSG NO LONGER DISPLYED
TESTS FAIL: (FAULT CONFIRMED) TESTS FAIL: (FAULT CONFIRMED)
PROCEED TO MEL/TSM FOR DEFERAL/TS
PROCEED TO MEL/TSM FOR
DEFERAL/TROUBLESHOOTING
Deyla torres, roberta graeffi, helena sampaio, daneila pires, vivian bovis, daniela
bonato, renata sacaahto, aline almeida, dayane horwort, kelly ely, andrea
golden, lisane dannski, tatiana dallpista, genaina faccil, gabriele gorito,
jaqueline urbano, jula vianna, samia, tacila cristina, bruna bruni, aline work,
aline boss, kelly jonr, tais vieira, cibele kowalski, juliana mara.

A320-232
FAULT VERIFICATION GUIDE

THIS DOCUMENT IS FOR TRAINING PURPOSES


ONLY AND WILL NOT BE REVISED ALWAYS
REFER TO UA MANUALS FOR CURRENT
APPROVED PROCEDURES