Bombas Multietapa
Bombas Multietapa
SLEEVE/KTB CONFIGURATION
Page 2 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
1 INTRODUCTION AND SAFETY Where applicable, the Directives and any additional
Approvals, cover important safety aspects relating to
1.1 General machinery and equipment and the satisfactory
provision of technical documents and safety
instructions. Where applicable this document
These Instructions must always be kept incorporates information relevant to these Directives
close to product's operating location or directly and Approvals. To confirm the Approvals applying
with the product. and if the product is CE marked, check the serial
number plate markings and the Certification, see
Flowserve's products are designed, developed and section 9, Certification.
manufactured with state-of-the-art technologies in
modern facilities. The unit is produced with great care
and commitment to continuous quality control, utilising 1.3 Disclaimer
sophisticated quality techniques, and safety
requirements. Information in these User Instructions is believed
to be reliable. In spite of all the efforts of
Flowserve is committed to continuous quality Flowserve to provide sound and all necessary
improvement and being at service for any further information the content of this manual may
information about the product in its installation and appear insufficient and is not guaranteed by
operation or about its support products, repair and Flowserve as to its completeness or accuracy.
diagnostic services.
Flowserve manufactures products to exacting
These instructions are intended to facilitate International Quality Management System Standards
familiarization with the product and its permitted use. as certified and audited by external Quality
Operating the product in compliance with these Assurance organisations. Genuine parts and
instructions is important to help ensure reliability in accessories have been designed, tested and
service and avoid risks. The instructions may not take incorporated into the products to help ensure
into account local regulations; ensure such regulations continued product quality and performance in use. As
are observed by all, including those installing the Flowserve cannot test parts and accessories sourced
product. Always coordinate repair activity with from other vendors the incorrect incorporation of such
operations personnel, and follow all plant safety parts and accessories may adversely affect the
requirements and applicable safety and health performance and safety features of the products. The
laws/regulations. failure to properly select, install or use authorised
Flowserve parts and accessories is considered to be
misuse. Damage or failure caused by misuse is not
These instructions must be read prior to covered by Flowserve's warranty. In addition, any
installing, operating, using and maintaining the modification of Flowserve products or removal of
equipment in any region worldwide. The original components may impair the safety of these
equipment must not be put into service until all products in their use.
the conditions relating to safety, noted in the
instructions, have been met. Failure to follow
and apply the present user instructions is 1.4 Copyright
considered to be misuse. Personal injury, All rights reserved. No part of these instructions may
product damage, delay or failure caused by be reproduced, stored in a retrieval system or
misuse are not covered by the Flowserve transmitted in any form or by any means without prior
warranty. permission of Flowserve Corporation.
Page 3 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
product for the application intended, contact 1.6.2 Personnel qualification and training
Flowserve for advice, quoting the serial number. All personnel involved in the operation, installation,
inspection and maintenance of the unit must be
If the conditions of service on your purchase order are qualified to carry out the work involved. If the
going to be changed (for example liquid pumped, personnel in question do not already possess the
temperature or duty) it is requested that the user seeks necessary knowledge and skill, appropriate training
Flowserve’s written agreement before start up. and instruction must be provided. If required the
operator may commission the manufacturer / supplier
1.6 Safety to provide applicable training.
1.6.1 Summary of safety markings Always co-ordinate repair activity with operations and
These user instructions contain specific safety health and safety personnel, and follow all plant safety
markings where non-observance of an instruction requirements and applicable safety and health laws
would cause hazards. The specific safety markings and regulations.
are:
1.6.3 Safety action
This is a summary of conditions and actions to
This symbol indicates electrical safety prevent injury to personnel and damage to the
instructions where non-compliance will involve a high environment and to equipment. (For products
risk to personal safety or the loss of life. used in potentially explosive atmospheres
section 1.6.4 also applies.)
Page 4 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
overheating of the pump, instability and cavitation/ If the temperature is greater than 68 °C (154°F) or
vibration. below -5 °C (20 °F) in a restricted zone, or
exceeds local regulations, action as above shall
be taken.
Do not run the pump at abnormally
high or low flow rates. Operating at a flow rate higher 1.6.4 Products used in potentially explosive
than normal or at a flow rate with no backpressure on atmospheres
the pump may overload the motor and cause pump
cavitation. Measures are required to:
• Avoid excessive temperature
• Prevent the build up of explosive mixtures
Never do maintenance work when • Prevent the generation of sparks
the unit is connected to power. • Prevent leakages
• Maintain the pump to avoid hazard
When the pump is handling hazardous
The following instructions for pumps and pump units
liquids care must be taken to avoid exposure to
when installed in potentially explosive atmospheres
the liquid by appropriate sitting of the pump,
must be followed to help ensure explosion protection.
limiting personnel access and by operator
Both electrical and non-electrical equipment must
training. If the liquid is flammable and/or
meet the requirements of European Directive
explosive, strict safety procedures must be
94/9/EC.
applied.
1.6.4.1 Scope of compliance
HANDLING COMPONENTS
Many precision parts have sharp corners and the
Use equipment only in the zone for which it is
wearing of appropriate safety gloves and
appropriate. Always check that the driver, drive
equipment is required when handling these
coupling assembly, seal and pump equipment are
components. To lift heavy pieces above 25 kg (55
suitably rated and/or certified for the classification of
lb) use an appropriate crane for the mass and in
the specific atmosphere in which they are to be
accordance with current local regulations.
installed.
Coupling guards must not be removed while Where Flowserve has supplied only the bare shaft
the pump is operational. pump, the Ex rating applies only to the pump. The
party responsible for assembling the ATEX pump set
shall select the coupling, driver and any additional
THERMAL SHOCK equipment, with the necessary CE Certificate/
Rapid changes in the temperature of the liquid Declaration of Conformity establishing it is suitable for
within the pump will cause thermal shock, which the area in which it is to be installed.
can result in damage or breakage of components
and should be avoided. The output from a variable frequency drive (VFD) can
cause additional heating effects in the motor and so,
for pumps sets with a VFD, the ATEX Certification for
HOT (and cold) PARTS the motor must state that it is covers the situation
If hot or freezing components or auxiliary heating where electrical supply is from the VFD. This
supplies can present a danger to operators and particular requirement still applies even if the VFD is
persons entering the immediate area action must in a safe area.
be taken to avoid accidental contact. If complete
protection is not possible, the machine access 1.6.4.2 Marking
must be limited to maintenance staff only, with An example of ATEX equipment marking is shown
clear visual warnings and indicators to those below. The actual classification of the pump will be
entering the immediate area. Note: bearing engraved on the nameplate.
housings must not be insulated and drive motors
and bearings may be hot.
Page 5 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Pumps have a temperature class as stated in the Ensure the pump and relevant suction and discharge
ATEX Ex rating on the nameplate. These are based pipeline system is totally filled with liquid at all times
on a maximum ambient temperature of 40 °C during the pump operation, so that an explosive
(104 °F); refer to Flowserve for higher ambient atmosphere is prevented. In addition it is essential to
temperatures. make sure that seal chambers, auxiliary shaft seal
systems and any heating and cooling systems are
The temperature of the liquid handled influences the properly filled. If the operation of the system cannot
surface temperature on the pump. The maximum avoid this condition, users shall fit an appropriate dry
permissible liquid temperature depends on the ATEX run protection device (e.g. liquid detection or a power
temperature class and must not exceed the values in monitor).
the table that follows.
To avoid potential hazards from fugitive emissions of
The temperature rise at the seals and bearings and vapor or gas to atmosphere the surrounding area
due to the minimum permitted flow rate is taken into shall be well ventilated.
account in the temperatures stated.
1.6.4.5 Preventing sparks
Temperature Maximum surface
Temperature limit of
class to temperature
liquid
prEN 13463-1 permitted
To prevent a potential hazard from mechanical
T6 85 °C (185 °F) Consult Flowserve contact, the coupling guard must be non-sparking
T5 100 °C (212 °F) Consult Flowserve
and anti-static for Category 2.
T4 135 °C (275 °F) 115 °C (239 °F) *
T3 200 °C (392 °F) 180 °C (356 °F) *
T2 300 °C (572 °F) 275 °C (527 °F) * To avoid the potential hazard from random induced
T1 450 °C (842 °F) 400 °C (752 °F) * current generating a spark, the baseplate shall be
*The table only takes the ATEX temperature class into properly grounded.
consideration. Pump design or material as well as component
design or material may further limit the maximum working
temperature of the liquid.
Avoid electrostatic charge: do not rub non-metallic
Page 6 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
surfaces with a dry cloth; ensure cloth is damp. If leakage of liquid to atmosphere can result in a
hazard, then a liquid detection device shall be
The coupling must be selected to comply with 94/9/EC installed.
and correct alignment must be maintained.
1.6.4.7 Maintenance to avoid the hazard
1.6.4.6 Preventing leakage
Page 7 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 8 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 9 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Each product has a unique serial number. Check that 2.2 Handling
this number corresponds with that advised and Boxes, crates, pallets or cartons may be unloaded
always quote this number in correspondence as well using forklift vehicles or slings dependent on their
as when ordering spare parts or further accessories. size and construction.
The condition of the skid and covering is indicative of The following information regarding lifting is
the way the shipment was handled. Broken skids, only offered as a general guideline. Flowserve
torn coverings, bent hold-down bolts, broken straps, requires that all lifting and rigging be performed in
etc. indicate rough handling. accordance with specifications set forth in Chapter 2,
Lifting and Rigging from API Recommended
The protective covers on the pump nozzles should be Practices 686/PIP REIE 686, First Edition.
in place and undamaged.
Page 10 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
2.3.2 To lift unit To lift the pump bottom half casing, slings can be
attached to the pump feet, casing boltholes or
padded slings can be used around the outer casing.
The complete unit with pump, driver
and auxiliary equipment all mounted on the baseplate 2.3.6 To lift pump rotor
can NOT be lifted as a unit. Driver must be removed Using slings that will not damage shaft, rig around
from baseplate before lifting. To lift unit sling shaft close to the impellers and to overhead hoist.
baseplate from all lifting eyes. Failure to do this may Carefully lift rotor from lower half casing.
result in permanent deformation of baseplate.
Damage to baseplate caused by mishandling or
improper setting prior to grouting is not covered by
Flowserve’s warranty.
Page 11 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Inspect all covers over pump openings and piping The responsibility for setting up an
connections. If covers or seals for the covers are inspection and maintenance schedule rests with the
damaged or loose, they are to be removed, and a customer and will be dependent upon the class/type
visual inspection made of the accessible interior of storage provided. It will be expected that initially
areas for accumulation of foreign materials or water. inspection would occur weekly, then depending upon
If necessary, clean and re-coat the interior parts with the inspection reports being favorable or unfavorable,
preservative to restore the parts to the “as shipped” inspection would continue weekly, monthly, or
condition. Install or replace covers and fasten secure. quarterly, as may be determined. Inspection reports
must be kept on file.
2.4.2 Storage area
When selecting a storage area, the following should Every inspection should consist of a general surface
be taken into consideration: inspection.
a) The deterioration of the equipment will be a) Pump supports are firmly in place.
proportionate to the class/type of storage
provided. b) Pump covers over openings are firmly in place.
b) The expenses involved in restoring the c) Pump coverings, plastics or tarps, are firmly in
equipment at time of operation will be place. Any holes or tears must be repaired to
proportionate to the class/type of storage prevent entrance of dirt or water.
provided.
d) Pump covers are periodically removed from
2.4.3 Storage preferred (dry) openings and interior accessible areas inspected.
If at all possible, the pump and its components If surface rusting has occurred, clean and repaint
should be stored indoors where they will be protected or re-coat with preservative.
from the elements. If it is not possible to store the
pump and its components indoors, precautions must e) If rusting occurs on exterior surfaces, clean and
be taken to protect them from the elements. repaint or re-coat with preservative.
Regardless of whether storage is inside or outside,
the storage area should be vibration-free. All boxes f) Loosen casing drain plugs to allow seepage of
that are marked for inside storage must be stored any accumulated moisture.
indoors. Coverings of heavy gauge plastic sheets,
canvas, waterproof burlap or other suitable coverings g) If the rotor is stored horizontally, rotate pump
should protect the pump and its components from rotor 1-1/4 revolutions at least once a month to
prevent rotor from taking a permanent set.
Page 12 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
The oil inlet blanking plates should be e) Dismantling may necessitate restoration of
removed and a small amount of oil injected into the painted or preserved surfaces, and/or
bearings before turning. Refit blanking plates. replacement of gaskets, “O” rings and
mechanical seal and bearings. Use only
h) Periodically remove bearing covers and inspect Flowserve recommended replacement materials.
for accumulation of moisture, rust and foreign
material. As required, clean bearings and bearing Upon completion of the inspection, the Flowserve
housing and re-preserve. Install bearing cover representative shall submit a report to the Customer,
and secure to assure maximum protection. and to the Manager of Customer Service, stating in
Bearings removed for storage should be coated detail the result of the inspection.
with preservative, wrapped in oil/wax paper, and
stored in a warm dry area. If there are any discrepancies identified, it is the
customer's responsibility for correction before initial
i) Check individually wrapped parts for signs of startup.
deterioration. If necessary, renew preservative
and wrapping. 2.4.4 Storage non-preferred (wet)
It is not recommended that the rotor be subjected to
extended periods of submergence or wetting prior to
If storage is over one month, start-up. However, it is recognized that in some
Instrumentation (Controls, Electrical devices, cases, a long period of time may lapse from
Temperature switches) should be removed and installation until commercial operation.
placed in a climate control environment if
Instrumentation is not powered up. If the pump must be stored after being installed and
wetted, the following inspection and maintenance
2.4.3.3 Prior to installation maintenance should be performed.
Six months prior to the scheduled installation date, a
Flowserve representative is to be employed to • Isolate the pump with valving - tag (seal) all
conduct an inspection. All costs involved during valves.
inspection, dismantling, restoration, replacement of
parts, and reassembly will be the responsibility of the • Preserve the pump internals.
customer. The customer will supply all necessary
labor, tools, and cranes. This inspection will include
(not necessarily in its entirety) but not be limited to If storage is over one month,
the following: Instrumentation (Controls, Electrical devices,
Temperature switches) should be removed and
a) An inspection of all periodic inspection records as placed in a climate controlled environment if
kept on file by the customer, and all inspection Instrumentation is not powered up.
reports that have been compiled during the
storage period.
Electric motors (pump driver) should
b) An inspection of the storage area to determine not be stored in damp places without special
the “as stored” condition of the equipment prior to protection (refer to motor manufacturer’s
any protection being removed. instructions).
Page 13 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
This solution, when drained, will result in a thin specifications must be in accordance with the current
residual oil film (less than 0.0127 mm (0.0005 in.)) on regulations at all times.
all internals after the water has evaporated. This
residue provides added corrosion protection until
pump is again filled with liquid or put into service.
Page 14 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
3.3.2 Impellers
The series’ impellers are single suction, enclosed
type, and one-piece construction and are dynamically
Single suction configuration balanced. They are fitted with renewable impeller
rings (front and back), which are held in place by
Single suction impeller at first stage (DMX) headless set-screws.
3.1.2 Double suction The impellers are keyed and have a shrink fit to the
pump shaft. They are held in axial position by a split
ring.
Page 15 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
3.3.11 Shaft
The high strength shaft is ground over its entire
length to close tolerances. The shaft is designed to
transmit the required power without vibration and is
stepped at each impeller fit for ease of assembly and
disassembly.
3.3.12 Bearings
The sleeve bearings are carbon steel backed, babbitt
lined, sleeve type insert bearings. The renewable
bearing inserts are mounted in bearing housings kept
from rotating by means of stop pins.
Each bearing is lubricated by an external pressure
supply system.
Page 16 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 17 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
this may result in permanent deformation of ASTM C 531-85, Test Method for Linear Shrinkage
baseplate. and Coefficient of Thermal Expansion of Chemical
Resistant Grouts and Monolithic Surfacing - Modified
Pump, driver auxiliary equipment and ASTM C 666-90, Test Method for Resistance of
piping shall be removed from the baseplate before Concrete to Rapid Freezing and Thawing
leveling the baseplate.
ASTM C 939-87, Test Method for Flow of Grout for
Locate the baseplate in its proper position on the Preplaced Aggregate Concrete (Flow Cone Method)
concrete block together with the leveling screws as
shown in the General Arrangement Drawing. ASTM C 942-86, Test Method for Compressive
Strength of Grouts for Preplaced Aggregate Concrete
Using a precision level across the machined surfaces in the Laboratory
of the pump and driver mounting pads, adjust leveling
screws as necessary to ensure that baseplate is ASTM C 1090-88, Test Method for Measuring
leveled in all directions. Changes in Height of Cylindrical Specimens from
Hydraulic Cement Grout
When the baseplate is leveled, snug the foundation
bolts, but do not completely tighten. ASTM C 1107-91, Standard Specification for
Packaged Hydraulic-Cement Grout (Non-Shrink)
4.2.3 Preliminary alignment
Using the previous procedure, adjust baseplate until (CRD-C 621-92), ACI 351, Grouting for Support of
pump and driver are within 0.076 mm (0.003 in.). Equipment and Machinery
The following ASTM Specifications are furnished as ASTM C-1181, Maximum Creep in 1 Year –
-3 o
references for test methods used in conjunction with 1.6X10 in./in. at 140 F, 400 psi
installation of grouting materials and should be used
to obtain proper results: ASTM C-307, Minimum Tensile Strength – 12.4 Mpa
(1800 psi)
ASTM C 78-84, Test Method for Flexural Strength for
Concrete ASTM C-580, Minimum Flexural Strength – 26.2 Mpa
(3800 psi)
ASTM C 109-90, Test Method for Compressive
Strength of Hydraulic Cement Mortars – Modified ASTM C-580, Minimum Flexural Secant Modulus –
4 6
1.2X10 Mpa (1.8X10 psi)
ASTM C 469-87a, Test Method for Static Modulus of
Elasticity and Poisson’s Ratio of Concrete in ASTM C-531, Maximum Coefficient of Expansion –
-6 o
Compression 17X10 in./in./ F. Maximum Peak Exotherm 1000 g
o o
(35.27 oz.) insulated – 35 C (95 F). Full Aggregate
ASTM C 496-90, Test Method for Splitting Tensile Must Be Used.
Strength of Cylindrical Concrete Specimens
Page 18 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
ALLOW AMPLE
4.3.1 Grouting material THREADED BOLT
LENGTH ABOVE
ROUGH FINISH ROUGH CONCRETE
4.3.1.1 Normal grout material FOR GROUT
A quality, high strength, non-shrink cementatious STUFF WASTE AROUND
grout material shall be used for installation. Epoxy is BOLT WHILE POURING
CONCRETE
preferred.
PIPE SLEEVE TO BE
4.3.1.2 Layered grout material THREE TIMES
DIAMETER OF ANCHOR
A layered combination of non-shrink cementatious BOLT
grout and normal industrial concrete can be used.
See sketch below for example. WELD A LARGE
WASHER WITH LUGS
TO THE BOTTOM OF
a) The first layer shall be 25 – 50 mm plus a layer of BOLT & PIPE SLEEVE
30 - 40 mm of normal grout material as described TO PREVENT
in 4.3.1.1. TURNING
b) The second layer is normal industrial concrete Foundation complete description
poured to a level that is approximately 30-40 mm
from the top of the baseplate decking. b) Build a dam around the foundation to contain
grout materials.
c) The top layer is 30-40 mm normal grout material
as described in 4.3.1.1.
Before grouting, check level of
30-40 mm machined pads of baseplate in both directions and
perform a rough shaft/coupling alignment. Alignment
c after grout has set will not be possible if above is not
Normal concrete b satisfactorily completed.
Page 19 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
e) Completely tighten the foundation bolts. Do not vibrate baseplate when grouting;
make sure baseplate is vented properly and all areas
4.3.3 Grouting method B indicated on General Arrangement drawing are
a) Prepare foundation properly as shown in the thoroughly filled to prevent any resonant problems.
General Arrangement Drawing. The bolt holes
shall be tapered to the top. e) When the grout is thoroughly hardened, remove
the dam.
GROUT
BASEPLATE
4.4 Initial alignment
4.4.1 Shaft/coupling alignment
LEVELING GROUT LEVELING
SCREW SPACE
The following information regarding shaft
alignment is only offered as a general guideline.
FOUDNATION Flowserve requires that all shaft alignment be
CONCRETE GROUT BOLT HOLES performed in accordance with specifications set forth
in Chapter 7, Shaft Alignment from API
FOUNDATION BOLTS
Recommended Practices 686/PIP REIE 686, First
Edition.
Page 20 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Angular misalignment
In offset misalignment, the shaft centerlines are
parallel but do not intersect. PUMP SIDE DRIVER SIDE
Offset misalignment
c) Laser alignment.
Page 21 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 22 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
d) Mount the laser emitter on the pump shaft, and The pump feet at the opposite end are held from
the laser target on the motor shaft. moving vertically by the use of a self-locking nut. The
clearance between the base of the nut and the top of
e) Link the shaft ends so they rotate together. the pump foot should be 0.051 mm (0.002 in.).
f) Adjust shim stack heights for vertical parallelism A “Gib Block” running parallel to the length of the
and angular alignment per laser unit’s output. pump foot at each of the outboard feet controls the
Make the necessary corrections by adding or by horizontal movement. The "Gib Blocks" are bolted
removing shims at the motor feet. and doweled to the pedestal. A 0.254 mm (0.010 in.)
gap is maintained between the "Gib Block" and pump
g) Adjust the motor position sideways for horizontal foot.
and angular alignment per the laser unit’s output
by using a soft mallet or adjusting screws.
The self-locking nuts, which hold the pump
h) Tighten all pump and motor feet fasteners. from moving in a vertical motion, are clamped
tight to the pump foot at time of shipment. The
i) Verify the final alignment 0.051 mm (0.002 in.) clearance must be
established at time of installation.
4.4.4 Check coupling alignment
The angular and offset coupling alignment must be DOWEL PIN (TYP) FLEX LOCK NUT 0.002"
rechecked. CLEARANCE
GIB GIB
BLOCK BLOCK
a) Coupling faces are to be parallel within
0.0254 mm (0.001 in.) TIR.
0.010"
b) Coupling outside diameters is to be aligned within
BASEPLATE BASEPLATE
0.0762 mm (0.003 in.) TIR. PEDESTAL PUMP PEDESTAL
FOOT
c) Motor-Driven: “Bump” the motor and check motor
rotation.
Gib block installation sketch for hot pump
d) Turbine-Driven: Check turbine rotation. (If wrong,
consult turbine manufacturer.) c) Pump Driver
Pumps handling liquids at temperatures of 94 °C a) Fully torque the hold-down bolts in the driver end
(200 °F) and over are designed to permit the casing of pumps feet to torque values listed in the
to expand with temperature away from coupling end instruction manual (refer to Sectional Assembly
of pump. The units that come under this classification Drawing in section 8).
must have the pump support feet dowelled to the
pedestal at the coupling end. This maintains the
coupling gap at the desired amount.
Page 23 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
b) Install the dowel pins in the pump drive end foot The design of piping, and related systems, is not the
by drilling the foot and the baseplate for the responsibility of Flowserve. It is therefore
tapered dowel provided. recommended that the customer consult a competent
specialist skilled in the field of piping, to insure proper
c) Position the gib blocks to obtain a 0.254 mm design/installation of all piping.
(0.010 in.) clearance between the gib block and
the side of the non-drive end pump foot as noted 4.5.1 Suction and discharge piping
on the attached figure. Drill and tap the cap These units are furnished for a particular service
screw holes for the gib blocks. condition. Changes in the hydraulic system may
affect performance adversely. This is especially true
d) Tighten the hold-down bolts for the gib blocks. if the changes reduce the pressure at the suction or if
the liquid temperature is increased. In case of any
e) Install the dowel pins in the gib blocks by reaming doubt contact the nearest Flowserve Office.
the block and baseplate for the tapered dowel
provided. Suction and discharge piping should be of ample
size, be installed in direct runs, and have a minimum
f) Tighten the hold-down locknuts on the non-drive of bends. Eccentric reducer shall be flat on top
end pump feet to establish a 0.051 mm (FOT).
(0.002 in.) gap between the locknut and the
pump foot. It is desirable to have at least seven (7) diameter of
straight pipe between the first elbow and the pump
4.4.8 Hot alignment check suction. Elbow in the piping to the pump’s suction
A hot check can only be made after the unit has been nozzle should be of the long radius type.
in operation a sufficient length of time to assume its
NORMAL operating temperature and conditions. If Seven (7) diameters of straight pipe should be used
the unit has been correctly cold set, the offset between two elbows in series and the pump suction.
misalignment will be within 0.076 mm (0.003 in.) TIR
and the angular misalignment will be within Elbows in more than one plane should not be used
0.0254 mm (0.001 in.) TIR when in operation. If not, without splitters.
make adjustments.
Splitters are placed in the elbow in the mean radius
line perpendicular to the plane of the elbow.
Do not attempt any maintenance,
inspection, repair or cleaning in the vicinity of
rotating equipment. Such action could result in Provision must be made to support
injury to operating personnel. piping external to the pump to prevent excessive
nozzle loads, maintain pump/driver alignment and
avoid pipe- induced vibrations.
Before attempting any inspection or repair
on the pump the driver controls must be in the Install a check valve and a gate valve in the
"off" position, locked and tagged to prevent discharge pipe of the pump. When the pump is
restarting equipment and injury to personnel stopped, the check valve will protect the pump
performing service on the pump. against excessive pressure and will prevent the pump
from running backward. The check valve should be
4.5 Piping installed between the gate valve and the pump
nozzle in order to permit its inspection. The gate
valve is also useful in priming and starting the pump.
The following information regarding
piping is only offered as a general guideline to the Keep the suction pipe short and direct. Use a suction
customer. Flowserve requires that all piping and pipe equal to or one size larger than the pump
related systems be designed/installed in accordance suction nozzle. Keep the suction pipe free of all air
with specifications set forth in Chapter 6, Piping from pockets.
API recommended practices 686/PIP REIE 686, First
Edition.
Page 24 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 25 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 26 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 27 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
b) Clean and flush bearing housings and lubrication Avoid severe thermal shocks to the pump as a result
system. (see pump lubricants). of sudden liquid temperature changes. The pump
must be preheated prior to start-up. Unless otherwise
c) Turn rotor by hand or with strap to make sure it specified, the external temperature of the casing
turns freely. must be within 55.6 °C (100 °F) of the temperature of
the liquid to be pumped at time of start-up.
d) Ensure that the mechanical seal is properly
assembled and tightened.
Pump temperature stratification could
occur. A maximum temperature delta of 28 °C (50 °F)
Most cartridge seals are equipped between the upper and lower case shall be checked
with a spacer between the gland plate and drive prior to starting the pump.
Page 28 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 29 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
5.2.3 Oil temperature a) Drain the oil in the bearing housing(s) and
replace with warm oil.
o
Oil temperature should be maintained between 16 C
o o o
(60 F) and 82 C (180 F). b) Heat the bearing housing(s) using heat tape (or
other suitable means).
The minimum bearing oil temperature c) Circulate warm liquid through the cooling jacket
o o
is 16 C (60 F). If necessary, prior to startup, one of or immersion cooler (if supplied).
the following procedures should be employed:
d) Utilize oil with a lower viscosity, or VG number, or
consider using a synthetics hydrocarbon oil with
Page 30 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
a low pour point to give a viscosity similar to that 5.4 Direction of rotation
of ISO 46 (for maximum oil operating
temperatures of 180 °F) or ISO 32 (for maximum
oil operating temperatures of 120 °F). Check pump rotating by starting
momentarily the direction of rotation is shown in 1.5
duty conditions, Note pump coasts to a gradual stop.
ISO 46 is recommended for continuous
operating oil temperatures between 38 °C (100 °F) 5.5 Guarding
and 82 °C (180 °F), with a minimum startup
temperature of 16 °C (60 °F); ISO 32 may be
considered for continuous operating oil temperatures Guarding is supplied and fitted to the pump
between 16 °C (60 °F) and 49 °C (120 °F), with a set.
minimum start up temperature of 4 °C (40 °F). For
startup when oil temperature is below 4 °C (40 °F), oil
preheating is recommended. Fasteners must remain captive in the guard
when the guard is removed to comply with
5.2.4 Cleaning the lubrication system prior to Machinery Directive 2006/42/EC.
operation
Before operating the pump, the lubrication system
should be thoroughly cleaned to remove any foreign Whenever guarding is removed or disturbed
matter that may have accumulated during shipment, ensure that all the protective guards around the
storage or installation. pump coupling and exposed parts of the shaft are
securely fixed.
To clean the lubrication system refer to the Sectional
drawing and proceeds as follows: 5.6 Priming and auxiliary supplies
a) Remove the bearing caps, bearing linings, thrust
shoes and drain plugs. Ensure all electrical, hydraulic,
pneumatic, sealant and lubrication systems (as
b) Flush out the bearing housings with kerosene or applicable) are connected and operational.
other suitable solvent.
c) Wash the bearing linings and thrust shoes with a Ensure the inlet pipe and pump casing
suitable solvent. are completely full of liquid before starting continuous
duty operation.
d) Flush the entire lubrication system with oil.
Flushing oil should be compatible with lubricating 5.7 Starting the pump
oil that will be used. Follow any instructions given
for the lubrication console.
5.7.1 Initial start up
e) During flushing operation, examine the piping for See 5.1.3 Initial start up procedure.
leaks and correct as necessary. Also check for
any obstructions that will interfere with free flow 5.7.2 Normal start up
of oil to the bearings. The starting procedure to be followed for normal
start-up is the same as that for initial start-up. When
f) After flushing, replace drain plugs. Reassemble automatic recycle valve is used, discharge valve can
bearings and torque end cover bolting. (Refer to be opened.
maintenance section.)
5.8 Running or operation
g) Refer to driver instruction book for instructions
covering flushing of driver bearings.
Do not wipe down in the vicinity of rotating
5.3 Impeller wearring clearance parts, if unusual noise or vibrations occur, secure
Please refer to the sectional drawing for ring and the pump as soon as possible.
bushing clearance value.
Page 31 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
c) Never operate the pump unless a liquid source is If pump stops abruptly when driver is shut
available. down, investigate for pump binding. Take necessary
remedial action before restarting pump.
d) Never operate the pump without proper
lubrication.
If pump is subjected to freezing
5.8.1 Operating checks temperatures, the pump must be drained of liquid to
prevent damage to pump.
In the interest of operator safety, the
unit must not be operated above or below the a) Close the pump suction and discharge valve.
nameplate conditions. Such operation could result in
unit failure causing injury to operating personnel. b) Close valve in bypass line.
Page 32 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
especially true if the changes reduce the pressure at There are two kinds of NPSH: The NPSHR by the
the suction flange or if the liquid temperature is pump, as shown on the pump curve, is the head
increased. In case of doubt, contact the nearest needed to cover the losses in the pump suction. The
Flowserve office. second NPSH is that available in the system, taking
into account the friction loss in suction piping, valves,
5.10.1 Specific gravity (SG) fittings etc. In all cases the NPSHA (measured above
The capacity and total head in m (ft) of liquid vapor pressure) must exceed the NPSHR in order to
developed by a centrifugal pump are fixed for every push the liquid into the pump.
point on the curve and are always at the same speed.
Neither capacity nor total head will be affected by a Failure to have an adequate margin of NPSHA over
change in the specific gravity of the liquid pumped. NPSHR will cause a reduction of pump performance
However, since the developed pressure in bar (psi) and internal damage to the pump.
and the power to drive the pump are a function of the
specific gravity of the liquid, both will be affected in
direct proportion by any change in specific gravity.
Therefore, a change in specific gravity will affect the
discharge gauge pressure and power. Any changes
should be noted, in that they may overload the
pump’s driver.
5.10.2 Viscosity
The pump is designed to deliver rated capacity at
rated head for a liquid with a particular viscosity.
Page 33 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Your pump is a precision machine. Take every When pump is handling "hot" liquid,
precaution to avoid damage or slight burrs to the extreme care must be taken to ensure safety of
shaft bearing areas, as well as any other ground, personnel when attempting to drain pump. Hot
finished surface when dismantling your pump. pumps must be allowed to cool before draining.
a) Tag driver controls in the "off" position. Before attempting any maintenance work on
pumps in vacuum service, pumps must be
Before attempting any inspection or repair isolated from suction and discharge system then
on the pump, the driver controls must be in the carefully vented to return pressure in pump
"off" position, locked and tagged to prevent casing to atmospheric pressure.
injury to personnel performing service on the
pump. 6.1 Maintenance schedule
Although your Flowserve pump has been designed
b) Isolating Pump. for extended, trouble-free service, certain preventive
maintenance measures should be performed on a
Before attempting to disassemble pump, regular basis to ensure optimum performance. A
pump must be isolated from system, by closing well-planned program of routine maintenance is the
suction and discharge system valves, drained of best assurance of dependable operation. The
liquid and cooled, if pump is handling hot liquid. following preventive maintenance (PM) inspections
are suggested as a minimum, and may be
c) Draining pump. supplemented by the experience of the operating
personnel.
Page 34 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Order number should be taken from 10.4 Customer b) CLASS 2 (Average): Covers recommended
Data sheet. spare parts for a single unit where additional
spare parts are not readily available.
For 24-Hour part ordering service, call Flowserve Suggested for Domestic Service handling
Distribution Center at +1 800 526 3569. abrasive or corrosive liquids where some
interruptions in service are permissible. This
To place an order, contact the nearest Flowserve includes Class 1 spares plus all renewable
office found at www.flowserve.com. wear parts.
Page 35 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
DMX/DMXD DMXH/DMXDH
STUD SIZE
PUMP PUMP When reassembling the pump, all fasteners
INCH UN 8 Nm lbfft Nm lbfft must be tightened to the correct torque value.
1.125 750 550 930 685 Failure to observe this warning could result in
1.250 1050 775 1310 965 injury to operating personnel.
1.375 1425 1050 1775 1310
1.500 1700 1250 2100 1550 6.6 Disassembly
1.625 2300 1700 2875 2120
1.750 3150 2320 3930 2900 For a better understanding of this section please refer
1.875 4200 3100 5220 3850
to the exploded views drawings in section 8.
2.000 4600 3400 5760 4250
6.6.1 Dismantling procedure
2.250 6670 4920 8340 6150
a) Remove all auxiliary piping and instrumentation
2.500 9220 6800 11525 8500
that will interfere with disassembly, and drain oil
2.750 12420 9160 15525 11450
from bearing housings.
3.000 16160 11920 20200 14900
Page 36 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
The use of a puller will be required to remove it from shims. Remove flinger [2540] and bearing seal
the shaft. ring [4020].
c) Remove cap-screws [6570] and dowel pins d) Install two eyebolts in diagonally opposite corners
[6810] from bearing housing [3200]. Rig eyebolt of bearing housing [3200] and rig to an overhead
[6820] in bearing housing cap to an overhead hoist. Remove cap-screws [6570] and dowel pins
hoist and lift bearing cap from bearing housing [6810] which secure bearing housing to casing.
and place on blocking on floor. Using the overhead hoist, lower and remove
bearing housing [3200] away from casing and
d) The inboard and outboard thrust bearing place on blocking on the floor.
assembly [3032] can now be removed from the
bearing housing [3200]. Tag assemblies to e) Remove cap screws [6570] and dowel pins
ensure they will be returned to their original [6810] from bearing lining [3020]. Remove upper
position. Refer to thrust bearing drawing and half of bearing lining. Raise shaft slightly and roll
instructions. out the lower half lining
e) Remove cap screws and dowel pins from bearing 6.6.6 Rotor removal
lining [3020]. a) Remove cap-nuts [6580] and washers [2905]
holding the upper half casing to the lower half.
f) Remove upper half of bearing lining. Raise shaft Remove dowel pins [6810]. Using jack-screws
slightly and roll out the lower half lining. [6570] in lower half casing, break the seal
between upper half and lower half casing. Rig
g) Remove cap-screws [6570] and dowel pins upper half casing to overhead hoist using the two
[6810] holding bearing housing [3200] to casing cast lifting lugs.
and remove bearing housing and place on
blocking on floor. The cast lifting lugs provided on upper half
casing are for lifting upper half casing only. Do
h) Loosen set screws [6570] in lock nut [3713]. not lift pump from these lugs.
Remove lock nut and bearing seal ring [4020].
Carefully lift upper half casing and place on
i) Remove thrust collar [3610] and key [6700]. boards to protect machine surfaces.
j) Remove thrust bearing shims [3126]. Record Casing wearing rings [1500], channel rings
thickness of shims and tie together to prevent [1500], throttle bushing [1630], center bushing [1600]
, seal chamber bushings [4132] and crossover
Page 37 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
bushing [1600] if double suction design (DMXD and After impeller is heated, it will have to be pushed
DMXDH) will be removed with rotor. towards the center of the pump, the split rings [2531]
removed and quickly pulled from the end of the shaft.
e) Remove channel rings [1500] from impeller back b) Maintaining temperature between. (191 °C –
ring at each impeller. Channel rings are 204 °C (375 °F – 400 °F) at the periphery, apply
horizontally split and are held together by heat down through the vane passages, thus
shoulder screws or dowel pins. heating the hub.
When heating parts, gloves or other suitable f) Remove casing ring [1500] from the next impeller
protection must be worn. on the outboard impellers.
Page 38 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
g) Repeat Steps c) and d) until all impellers are If new casing rings are used, make sure that they
removed on the outboard impellers. seat in both the upper and lower half casing and
that the anti-rotation device is properly located in
its respective lower half casing fit. The use of a
Let entire rotor cool after removing several scraper on the ring to casing fit will help to fit the
components with heat as there may be a build-up of ring to the casing.
heat in the rotor.
e) Using a torch could change the metallurgy of the
h) Heat must be applied to remove center sleeve rings if too much heat is applied. Removing
[2450]. impellers with torch is acceptable but putting on
new impeller rings shall be done with oven
i) Continue to disassemble the impellers by instead of torch.
repeating steps c) and d) until all impellers [2200]
have been removed from the shaft. 6.7.2 Dynamic-balance impeller
Whenever an impeller is tampered with, (i.e. new
impeller, wear rings installed etc.) the impeller must
In case of double suction pump (DMXD and be dynamically balanced before being reassembled
DMXDH), remove crossover sleeve [2450] after the to shaft.
first stage impeller is removed by applying heat.
Dynamic balance shall be performed on a suitable
6.6.9 Impeller ring removal balancing machine by trained personnel.
Remove impeller rings by removing the set-screws
[6570] and machine off. Two balance planes shall be used and located
equidistance as possible from the center of gravity of
6.6.10 Parting flange gasket the impeller.
Remove all traces of old gasket [4590] material.
When using any tool to surfaces remove gasket Metal shall be removed from the impeller shrouds
material, do not gouge machined surfaces. Do not during the balancing operation in accordance with the
reuse the gasket once the casing is opened. Use only attached sketches until the impeller is within
Flowserve recommended replacement materials. acceptable tolerance limit of unbalance.
Page 39 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Grinding must not be performed in the area within 6.8.3 Impeller ring installation
19mm (¾") of the final diameter of the impeller. Impellers ring setscrews can be either axial or radial
Grinded area’s shall have a smooth transition to the through the hub.
not grinded areas and shall be polished. Minimum
thickness of impeller shrouds after balancing may not Make sure ring fit on impeller is free of nicks and
be less than 80% of the nominal thickness per detail burrs. Install the set-screws in the tapered holes on
drawing. the ring fits. Radial set screw shall be installed in
such a way that the socket end is accessible from the
6.8 Assembly of pump and seal inside of the impeller and the point end is just slightly
When reassembling pump, all fasteners must be below the ring fit land. It may be easier to install the
tightened to the proper torque values. Refer to radial set screw from the outside of the impeller.
sectional drawing in section 8.
Heat the new ring to 148°C. (300°F.) in convection
6.8.1 Bearing handling information oven to allow for uniform heating. Do not use a torch
Bearings require proper handling and installation to as this may cause local re-tempering of the material.
ensure optimum performance. The following
information is intended as a minimum to ensure that After the rings are thoroughly heated, they can be
the bearings are handled and installed properly. assembled on the impeller hubs. Only one of the
internal edges has been machined with a lead in
a) Do not remove new bearings from their storage chamfer. Radial location is unimportant as the
package except to inspect the bearings, when uniform cross-section around the circumference. Ring
stored for a long period of time or just prior to must fit up against the shoulder provided on hubs for
their installation. proper assembly.
b) Work area must be clean to ensure that no dirt or After cooling tighten all the set-screws with an allen
other contaminates will enter the bearings. wrench.
Handle bearings with clean, dry hands and with
clean, lint free rags. Lay bearing on clean paper Rings were machined to final size. They do not have
and keep covered. Never expose bearings on a to be turned after assembly.
dirty bench or floor.
Page 40 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Typical axial screw installation for impeller rings. In case of double suction pump (DMXD and
DMXDH), install crossover sleeve [2450] before
6.8.4 Rebuilding rotor assembling the first stage impeller.
Before upstaging or destaging a pump Let entire rotor cool after removing several
(adding or removing impellers), contact Flowserve components with heat as there may be a build-up of
Customer Service department for instructions, to heat in the rotor. It's recommended that runout of
avoid permanent damage to the pump rotor. shaft be checked.
b) All impeller bores and shaft outside diameters are 6.8.5 Indicate and dynamic balance rotor
to be dimensionally inspected. a) Place the rotor assembly on "V" blocks or rollers.
The runout of all impeller wear rings and
bushings is not to exceed 0.05 mm (0.002 in.)
Impeller-to-shaft fit must be minimum TIR.
of 0.0254 mm (0.001in.) to 0.0762 mm (0.003 in.)
interference fit. b) All pump rotors are to be dynamic balanced.
c) Heat the center impeller [2200] in the suction Refer to 6.7.2 section for grinding for balance
side in oven, and assemble to shaft, moving the information.
impeller past the split ring groove in the shaft.
Quickly install split ring [2531] and pull impeller 6.8.6 Installing rotor in casing
back to seat against split ring. Constant heat a) The seal chamber bushing [4132], throttle
source is preferred to torch; torch is not bushing [1630], channel rings [1500] and center
recommended. bushing [1600] should be checked to make sure
they seat in both the upper and lower half casing
and that the anti-rotating pins [2923] can be
Page 41 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
properly located in the slot on the lower half j) Install the upper half of center bushing [1600] and
casing parting flange. seat taper dowel pins [6810]. Install cap-screws
[6570] and tighten.
b) Install main parting flange gasket [4590]. Refer to
parting flange gasket.
In case of double suction pump (DMXD and
c) Place lower half of the center bushing [1600] into DMXDH), Install the upper half of crossover bushing
the lower half casing [1210], making sure the [1600] and seat taper dowel pins [6810].
anti-rotation pins are properly located in the slot
on the lower half casing parting flange. k) Install upper half of channel rings [1500] and seat
shoulder screws or dowel pins.
In case of double suction pump (DMXD and l) Check rotor axial float as described in 6.8.8.
DMXDH), place lower half of the crossover bushing
[1600] into the lower half casing [1210], making sure m) Rig upper half casing [1210] to an overhead
the anti-rotation pins are properly located in the slot hoist. Refer to lifting equipment section.
on the lower half casing parting flange.
n) Position upper half casing over lowers half and
d) Place the lower half of all channel rings [1500] in lower carefully, making sure all rings and
lower half casing, in the same sequence as they bushings enter their proper fit.
were removed, making sure the anti-rotation pins
are properly located in the slot on the lower half o) Install main parting flange dowel pins [6810] and
casing parting flange. seat.
Page 42 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
d) If this minimum movement is not obtained, the • Wipe a film of oil on journal area of shaft.
cause must be investigated and corrected. Place lower half of bearing lining on shaft.
Wipe a film of oil on lower half of bearing
6.8.8 Check rotor axial float lining. Roll lower half of bearing lining into
a) Push the rotor toward the coupling end as far as lower half of bearing housing [3200].
it will go.
b) Assemble Thrust Bearing:
Page 43 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
c) Install dial indicator on thrust bearing housing i) Rig bearing housings [3200] to an overhead
[3200] so indicator contacts end of shaft. Set hoist. Assemble bearing housings [3200] to
indicator at zero. casing. Install dowel pins [6810] and snug cap-
screws [6570].
d) Push rotor outboard to ensure contact between
thrust bearing [3013] and bearing housing [3200].
When installing bearing housings to casing,
e) Read the distance the shaft moved on the dial ensure flingers [2540] are properly positioned with
indicator. This is the amount of shims [3126] to the inner part of the bearing housing. Refer to pump
be installed between thrust collar [3610] and sectional drawing in section 8 of this manual.
shoulder of shaft.
j) Tighten bearing-body-to-casing screws [6570] to
f) Remove masking tape. the proper torque value.
b) Roll out both lower half bearing linings [3020]. k) Wipe a film of oil on journal area of shaft. Place
Remove both bearing housings [3200]. lower half of bearing lining on shaft. Wipe a film
of oil on lower half of bearing lining. Roll lower
c) Remove thrust collar lock nut [3713] and thrust half of bearing lining into lower half of bearing
collar [3610]. housing [3200].
d) Install both completely assembled mechanical l) Place upper half of bearing lining [3020] in
seals to shaft . Insert into seal chamber. Do not position on top of shaft.
tighten gland nuts [6580] or mechanical seal
drive collar at this time. m) Ensure bearing housings [3200] and parting-
flange surfaces are clean and free of dry
e) Position inboard flingers [2540] and outboard “permatex”. Coat flange with new “permatex”.
flingers [2540] onto shaft and place in their Assemble bearing housings [3200]. Install dowel
approximate position. Refer to pump sectional pins [6810] and cap-screws [6570]. Tighten cap-
drawing in section 8 of this manual. screws to the proper torque value.
f) Slide inboard thrust bearing seal ring [4010] over n) Assemble lower half of bearing lining [3020] to
shaft (refer to thrust bearing drawing and thrust bearing housing in the same manner as
instructions). Rest it on shaft in its proper Step k).
position. (Refer to pump assembly drawing).
o) Assemble upper half of bearing lining [3020] in
g) Install shims [3126}. the same manner as step l).
Page 44 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
p) Assemble outboard thrust bearing seal ring c) Ensure seal gland is seated properly in seal
[4010] to shaft and temporarily assemble support chamber bore. Assemble washers [2905] and
head [3830] or end cover [3266] to bearing tighten nuts [6580] to the proper value. Tighten
housing. Secure two cap screws. drive collar.
c) Install a dial indicator on coupling end bearing j) Refer to Running or operation section for starting
housing so the indicator contacts the end of the procedure.
shaft. Push the rotor outboard (towards thrust
bearing) and set indicator at zero. Push rotor 6.8.14 Parting flange gasket
inboard. Indicator should read 0.23 mm (0.009 a) Using proper recommended 0.397 mm (1/64 in.)
in.) to 0.33 mm (0.013 in.). Add or remove shims thick gasket material, locate and cut stud holes,
[3126] to obtain the proper end-play. Coat end of using upper half casing as a template.
bearing housings with “permatex” and
reassemble end cover, torque and recheck end- b) Lay gasket on lower half casing, using either a
play. gasket adhesive or a band of shellac
approximately 13 mm (1/2 in.) wide on the outer
6.8.13 Final assembly edge of lower casing.
a) Position bearing flingers [2540] approximately
1.02 mm (0.040 in.) away from end covers and c) Place upper half casing on top of gasket and
tightens the set-screws [6570]. allow time for gasket adhesive or shellac to set
up.
b) If pump is equipped with shaft driven oil pump,
assemble "driver half" of coupling to oil pump. d) Remove upper half casing.
Position "coupling spider" in the driver half
coupling. Assemble oil pump with its gasket to e) Using a sharp knife, cut gasket with downward
support head. Tighten nuts to proper torque strokes only. Make sure all cuts are neat and
value. exact, especially on internal edges of casing. If
Page 45 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
DISCHARGE
PASSAGE Parting flange torque procedure diagram
Page 46 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
FAULT SYMPTOM
Pump overheats and seizes
⇓ Bearings have short life
⇓ Pump vibrates or is noisy
⇓ Mechanical seal has short life
⇓ Mechanical seal leaks excessively
⇓ Pump requires excessive power
⇓ Pump loses prime after starting
⇓ Insufficient pressure developed
⇓ Insufficient capacity delivered
⇓ Pump does not deliver liquid
⇓ PROBABLE CAUSES POSSIBLE REMEDIES
A. SYSTEM TROUBLES
Pump not primed. Check complete filling. Vent and/or prime.
Pump or suction pipe not completely filled
with liquid.
Suction lift too high or level too low. Check NPSHa>NPSHr, proper submergence, losses at
strainers and fittings
Insufficient margin between suction pressure
and vapor pressure.
Excessive amount of air or gas in liquid. Check and purge pipes and system.
Air or vapor pocket in suction line. Check suction line design for vapor pockets
Air leaks into suction line. Check suction pipe is airtight.
Air leaks into pump through mechanical seal, Check and replace faulty parts.
sleeve joints, casing joint or pipe plugs. CONSULT FLOWSERVE.
Inlet of suction pipe insufficiently submerged. Check out system design
Speed too low. CONSULT FLOWSERVE.
Speed too high. CONSULT FLOWSERVE.
Total head of system higher than differential Check system losses.
head of pump. Remedy or CONSULT FLOWSERVE.
Total head of system lower than pump design
head.
Specific gravity of liquid different from design. Check and CONSULT FLOWSERVE.
Viscosity of liquid differs from that for which
designed.
Operation at very low capacity. Measure value and check minimum permitted.
Remedy or CONSULT FLOWSERVE.
Operation at high capacity. Measure value and check maximum permitted.
Remedy or CONSULT FLOWSERVE.
Suction pressure too low, Foreign material in Open suction valve, Check power supply to correct voltage,
suction line. Dismantle suction line remove foreign material.
B. MECHANICAL TROUBLES
Misalignment due to pipe strain. Check the flange connections and eliminate strains using
elastic couplings or a method permitted
Misalignment due to improper pump/driver Check alignment and correct as necessary.
setup.
Improperly designed foundation. Check setting of baseplate: tighten, adjust, grout base as
required.
Page 47 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
FAULT SYMPTOM
Pump overheats and seizes
⇓ Bearings have short life
⇓ Pump vibrates or is noisy
⇓ Mechanical seal has short life
⇓ Mechanical seal leaks excessively
Page 48 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 49 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 50 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 51 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 52 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 53 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Page 54 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
9 CERTIFICATION Reference 5:
ANSI B31.3 - Process Piping.
Certificates determined from the Contract
requirements are provided with these instructions
where applicable. Examples are certificates for CE
marking, ATEX marking etc. If required, copies of
other certificates sent separately to the Purchaser
should be obtained from the Purchaser for retention
with these User Instructions.
10 OTHER RELEVANT
DOCUMENTATION AND MANUALS
Reference 2:
th
Pumping Manual, 9 edition, T.C. Dickenson,
Elsevier Advanced Technology, United Kingdom,
1995.
Reference 3:
nd
Pump Handbook, 2 edition, Igor J. Karassik et al,
McGraw-Hill Inc., New York, 1993.
Reference 4:
ANSI/HI 1.1-1.5
Centrifugal Pumps - Nomenclature, Definitions,
Application and Operation.
Page 55 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
Driver:
Pump rating:
Total Head:
Suction pressure:
Discharge pressure:
Minimum flow:
Page 56 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
NOTES:
Page 57 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
NOTES:
Page 58 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
NOTES:
Page 59 of 60
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09
FLOWSERVE REGIONAL
Your Flowserve factory contacts: SALES OFFICES:
Flowserve Corporation
Parallelweg 6 USA and Canada
4878 AH Flowserve Corporation
Etten-Leur, The Netherlands 5215 North O’Connor Blvd.,
Telephone: +31 76 502 8200 Suite 2300
Irving, Texas 75039-5421 USA
Flowserve Spain, S.A. Telephone 1 972 443 6500
Poligono Industrial Fax 1 972 443 6800
Avda. Fuentemar, 26-28
E28823 Coslada (Madrid), Spain Europe, Middle East, Africa
Telephone: +34 91 660 4600 Worthing S.P.A.
Flowserve Corporation
Flowserve S.A. Via Rossini 90/92
Chuquisaca 302
20033 Desio (Milan) Italy
5547 Godoy Cruz
Telephone 39 0362 6121
Mendoza, Argentina
Fax 39 0362 303396
Telephone: +54 261 405 3100
Latin America and Caribbean
Flowserve Corporation
Flowserve Corporation
2300 East Vernon Avenue
6840 Wynnwood Lane
Vernon, CA, USA 90058
Houston, Texas 77008 USA
Telephone: +1 323 587 6171
Telephone 1 713 803 4434
Fax 1 713 803 4497